Advertisement for orthosearch.org.uk
Results 1 - 20 of 288
Results per page:

Abstract. Introduction. Cementless fixation of Oxford Unicompartmental Knee Replacements (UKRs) is an alternative to cemented fixation, however, it is unknown whether cementless fixation is as good long-term. This study aimed to compare primary and long-term fixation of cemented and cementless Oxford UKRs using radiostereometric analysis (RSA). Methodology. Twenty-nine patients were randomised to receive cemented or cementless Oxford UKRs and followed for ten years. Differences in primary fixation and long-term fixation of the tibial components (inferred from 0/3/6-month and 6-month/1-year/2-year/5-year/10-year migration, respectively) were analysed using RSA and radiolucencies were assessed on radiographs. Migration rates were determined by linear regression and clinical outcomes measured using the Oxford Knee Score (OKS). Results. Preliminary analysis of Maximum Total Point Motion (MTPM) indicated cementless tibial components undergo significantly more migration than cemented components during the first 6 months (1.6mm/year, SD=0.92 versus 1.3mm/year, SD=1.1, p<0.001). Cementless migration was predominantly subsidence inferiorly (Mean=0.51mm/year, SD=0.29, p<0.001) and posteriorly (0.13mm/year, SD=0.21, p=0.03). Contrastingly, from 6 months to 10 years cemented components migrated significantly (MTPM=0.039mm/year, SD=0.11, p=0.04) whereas cementless components did not (MTPM=0.002mm/year, SD=0.02, p=0.744). Radiolucent lines occurred more frequently below cemented (10/13) than cementless (4/16) tibial components, but radiolucencies did not correlate with differences in migration or OKS. There was no significant difference in OKS between cemented and cementless. Conclusion. These results suggest that cementless tibial components migrate more than cemented before achieving primary fixation. However, long-term fixation of cementless tibial components appears to be as good, if not better, than cemented with the benefit of fewer radiolucent lines


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_10 | Pages 52 - 52
1 Oct 2020
Huddleston JI De A Jaffri H Barrington JW Duwelius PJ Springer BD
Full Access

Introduction. Patients with FNF may be treated by either total hip arthroplasty (THA) or hemiarthroplasty (HA). Utilizing American Joint Replacement Registry (AJRR) data, we aimed to evaluate outcomes in FNF treatment. Methods. Medicare patients with FNF treated with HA or THA reported to the AJRR database from 2012–2019 and CMS claims data from 2012–2017 were analyzed in this retrospective cohort study. “Early” was defined as less than 90 days from index procedure. A logistic regression model, including index arthroplasty, age, sex, stem fixation method, hospital size. 1. , hospital teaching affiliation. 1. , and Charlson comorbidity index (CCI), was utilized to determine associations between index procedure and revision rates. Results. Of 75,333 FNF procedures analyzed, 82.2% had HA. 8.4% had cemented fixation. 36.9% had cementless fixation. Fixation was unknown for 41,225 (54.7%) patients. 90-day readmissions rates were 1.3% for both cohorts. Both the early revision rate (0.9% HA vs. 1.3% THA, p<0.0001) as well as the overall revision rate (1.5% HA vs. 2.3% THA, p<0.0001) were higher in the THA cohort. The three most common reasons for any revision were instability (26%), infection (21%), and periprosthetic fracture (15%). Higher rates of any revision were associated with cementless fixation (OR=1.37, 95% CI 1.20–1.57) and increased age (OR=0.96, 95% CI 0.96–0.97). THA and increased age were risk factors for early and any revision for instability. Cementless fixation, female sex, and decreased age were associated with lower revision rates for infection. Conclusion. The most common surgical treatment for FNF reported to the AJRR was cementless stem fixation and hemiarthroplasty. The higher revision rates for FNF treatment with THA warrant further investigation. The use of cemented femoral fixation in this patient population may be under-utilized. These data provide a benchmark of US practice for reference and comparison to other practices throughout US and the world


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_22 | Pages 73 - 73
1 May 2013
Thornhill T
Full Access

Cementless femoral fixation in total knee replacement has proven to be successful in many studies. There is a recent report by Berger et al, on failure of cementless fixation in a high flexion TKR design. This was with a FiberWire material that had good ingrowth characteristics but was not ideal in terms of immediate fixation. Cementless patellar fixation to date has required a metal backed patella, which has proven to be problematic in most design. For this reason, most surgeons who resurface the patella do so with an all-polyethylene cemented design. The major controversy is cemented tibial fixation. This is problematic when performed with ancillary screw fixation due to screw osteolysis. There are newer designs that have shown promise but cemented tibial fixation remains the gold standard. It is true that early designs of cementless hips were associated with poor results, but newer designs have led to cementless fixation in total hip arthroplasty as the gold standard. It is clear that with newer materials, ancillary biologics and improved design that cementless total knee fixation will eventually prevail. At the present time, the wine needs to stay in the cellar for now


The Bone & Joint Journal
Vol. 95-B, Issue 2 | Pages 181 - 187
1 Feb 2013
Liddle AD Pandit H O’Brien S Doran E Penny ID Hooper GJ Burn PJ Dodd CAF Beverland DE Maxwell AR Murray DW

The Cementless Oxford Unicompartmental Knee Replacement (OUKR) was developed to address problems related to cementation, and has been demonstrated in a randomised study to have similar clinical outcomes with fewer radiolucencies than observed with the cemented device. However, before its widespread use it is necessary to clarify contraindications and assess the complications. This requires a larger study than any previously published. We present a prospective multicentre series of 1000 cementless OUKRs in 881 patients at a minimum follow-up of one year. All patients had radiological assessment aligned to the bone–implant interfaces and clinical scores. Analysis was performed at a mean of 38.2 months (19 to 88) following surgery. A total of 17 patients died (comprising 19 knees (1.9%)), none as a result of surgery; there were no tibial or femoral loosenings. A total of 19 knees (1.9%) had significant implant-related complications or required revision. Implant survival at six years was 97.2%, and there was a partial radiolucency at the bone–implant interface in 72 knees (8.9%), with no complete radiolucencies. There was no significant increase in complication rate compared with cemented fixation (p = 0.87), and no specific contraindications to cementless fixation were identified. Cementless OUKR appears to be safe and reproducible in patients with end-stage anteromedial osteoarthritis of the knee, with radiological evidence of improved fixation compared with previous reports using cemented fixation. Cite this article: Bone Joint J 2013;95-B:181–7


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_II | Pages 191 - 191
1 Feb 2004
Iosifidis M Malioufas L Giannoulis J Tomtsis K Traios S Giantsis G
Full Access

The aim of this study is to present the early results of our department’s experience, about cementless fixation of femoral component in total knee replacement. During the period 1997–2002 from the patients who treated surgically for knee osteoarthratis, 285 were followed up p.o. from 6 months up to 5 years (mean 30 months). They were 246 women and 39 men (mean age 69,4 years), to whom we used unconstrained total knee arthroplasty. For all of them, we didn’t use orthopaedic cement to fix the femoral component and there were no case of patella replacement. All the patients were examined clinically and with x-rays (Knee Society Roentgenographic Evaluation and Scoring System). The answer to the question about the use or not of orthopaedic cement for femoral component fixation is not clear in the international literature. There is the attitude of using cement every time or depending the use of cement on patient’s age and bone quality. On the other hand, many orthopaedic surgeons, like us, never use cement (except for the very osteoporotic bone). There were no cases of femoral component’s loosening in our data. In conclusion, we believe that the cementless fixation of femoral component in total knee replacement offers satisfactory stabilization of the component, the same as the cemented fixation offers, according to the international literature


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_22 | Pages 72 - 72
1 May 2013
Hofmann A
Full Access

In properly chosen patients, cementless total knee arthroplasty has achieved success rates equal to cemented designs. The initial variable results of early cementless total knee replacements were a function of design, surgical technique and patient selection. Important design considerations that have enhanced biologic ingrowth include the use of commercially pure titanium with optimal pore size and porosity, and avoidance of porous-coated stems and plugs that cause stress shielding of the bone-implant interface. Factors in surgical technique that enhance bone ingrowth include precise bone cuts that maximize bone-implant contact, and the application of autogenous bone slurry to cut surfaces. Additional factors are restoration of normal alignment, appropriate ligament balance, and the reproduction of the patient's native tibial slope in order to prevent tibial component subsidence. Young and active patients are ideal biological hosts for the use of cementless knee fixation. Their relatively dense cancellous bone and rich blood supply provides for robust purchase for initial fixation and the appropriate milieu for long-term biologic fixation. With increasing life expectancy, this more durable interface is desirable. With avoidance of porous-coated stems and pegs and prevention of fibrous tissue attachment, potential future revisions are more bone-sparing relative to methylmethacrylate fixation. Numerous reports, as well as the authors' published 10- to 14-year results, demonstrate that cementless fixation in appropriately selected patients provides results comparable to cemented TKA, with the advantage of conserving bone stock and eliminating the potential problems of cement fixation


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_II | Pages 322 - 322
1 May 2010
Jämsen E Pajamaki J Moilainen T
Full Access

Antibiotic-impregnated cement is frequently used for fixation of total knee prostheses as a measure to prevent postoperative infection. In recent years, more cementless knee prostheses have been implanted especially for younger patients. In 1997 to June 2004, 35044 primary total knee arthroplasties for primary or secondary osteoarthritis were performed in Finland and registered in nationwide arthroplasty register. The patients aged 70 years (range 21–96) on average, and 71.7% were women. During the median follow-up of 39 months (range 0–104), 978 (2.8%) knees were revised. There were 188 (0.58%), 21 (1.09%) and 10 (1.18%) reoperations due to infection after cemented, hybrid and cementless arthroplasties, respectively (p=0.003). In hybrid arthroplasties with cemented tibial component, the septic reoperation rate did not significantly differ from cemented arthroplasties. Instead, the higher number of infections after hybrid arthroplasty was related to use of cementless tibial components (5.3% vs. 0.9%, p< 0.008). In Cox regression model adjusted for age, gender and diagnosis, the hazard ratio for septic reoperation after knee replacement with cementless tibial component was 2.4 (95% CI 1.4–4.1) compared to the cemented alternative. The fixation method did not affect the rate of septic reoperations occurring after the first postoperative year. Cementless fixation of tibial component in primary total knee arthroplasty may associate with an increased risk of early septic reoperation. Until this finding is confirmed in other materials, cementless fixation in primary knee arthroplasty should be used cautiously in patients with increased risk for infection


The Bone & Joint Journal
Vol. 104-B, Issue 2 | Pages 206 - 211
1 Feb 2022
Bloch BV White JJE Matar HE Berber R Manktelow ARJ

Aims. Total hip arthroplasty (THA) is a very successful and cost-effective operation, yet debate continues about the optimum fixation philosophy in different age groups. The concept of the 'cementless paradox' and the UK 'Getting it Right First Time' initiative encourage increased use of cemented fixation due to purported lower revision rates, especially in elderly patients, and decreased cost. Methods. In a high-volume, tertiary referral centre, we identified 10,112 THAs from a prospectively collected database, including 1,699 cemented THAs, 5,782 hybrid THAs, and 2,631 cementless THAs. The endpoint was revision for any reason. Secondary analysis included examination of implant survivorship in patients aged over 70 years, over 75 years, and over 80 years at primary THA. Results. Cemented fixation had the lowest implant survival in all age groups, with a total ten-year survivorship of 97.0% (95% confidence interval (CI) 95.8 to 97.8) in the cemented group, 97.6% (95% CI 96.9 to 98.1) in the hybrid group, and 97.9% (95% CI 96.9 to 98.6) in the cementless group. This was not statistically significant (p = 0.092). There was no age group where cemented fixation outperformed hybrid or cementless fixation. Conclusion. While all fixation techniques performed well at long-term follow-up, cemented fixation was associated with the lowest implant survival in all age groups, including in more elderly patients. We recommend that surgeons should carefully monitor their own outcomes and use fixation techniques that they are familiar with, and deliver the best outcomes in their own hands. Cite this article: Bone Joint J 2022;104-B(2):206–211


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IX | Pages 31 - 31
1 Mar 2012
Kendrick B Pandit H Jenkins C Beard D Gill H Price A Dodd C Murray D
Full Access

Purpose of Study. To assess the incidence of radiolucency in cemented and cementless Oxford unicompartmental knee replacement at two years. Introduction. Most unicompartmental knee replacements (UKRs) employ cement for fixation of the prosthetic components. The information in the literature about the relative merits of cemented and cementless UKR is contradictory, with some favouring cementless fixation and others favouring cemented fixation. In addition, there is concern about the radiolucency that frequently develops beneath the tibial component with cemented fixation. The exact cause of the occurrence of radiolucency is unknown but it has been hypothesised that it may suggest suboptimal fixation. Method. Following ethical approval, 62 patients with medial OA were randomised to receive either cemented (n=32) or cementless components (n=30). All patients underwent an identical surgical procedure with either a cemented or cementless Oxford UKR. Patients were assessed clinically by a research physiotherapist and radiologically using screened radiographs. Thirty-eight patients from the trial with follow up of at least two years and well aligned radiographs were identified (cemented n=16, cementless n=22). Results. The patients in the two groups were well matched. Radiological and clinical assessment was at a mean of 2.25 years. There was no significant difference in the clinical scores between the two groups. The median OKS for the cemented group was 43 and for the cementless group was 42.5. Narrow radiolucent lines were seen at the bone-implant interfaces of 63% of the cemented tibial components; partial in 38% and complete in 25%. In the cementless implants, partial radiolucencies were seen in 4.5% and complete radiolucencies in none. The differences are statistically highly significant (p< 0.0001). The lack of radiolucency beneath the cementless tibial components implies satisfactory bone ingrowth and hence fixation. Conclusions. At 2 years the cementless components are well fixed and have similar clinical results to the cemented


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_III | Pages 412 - 412
1 Sep 2009
Pandit H Jenkins C Beard D Gill H Marks B Price A Dodd C Murray D
Full Access

Introduction: The information in the literature about the relative merits of cemented and cementless unicompartmental knee replacement (UKR) is contradictory, with some favouring cementless fixation while others favouring cemented fixation. Cemented fixations give good survivorship but there is concern about the radiolucency which frequently develops around the tibial component. The exact cause of the occurrence of radiolucency is unknown but according to some, it may suggest suboptimal fixation. Method: Sixty-two knees (31 in each group) were randomised to receive either cemented or cementless UKR components. The components were similar except that the cementless had a porous titanium and hydroxyappatite (HA) coating. Patients were prospectively assessed by an independent observer pre-operatively and annually thereafter. The clinical assessment included Oxford Knee Score, Knee Society Scores and Tegner activity score. Fluoroscopically aligned radiographs were assessed for thickness and extent of radiolucency under the tibial implant. Results: At one year there were no differences in the clinical outcome between the groups and there were no loose components. No radiolucencies thicker than 1mm were seen. At one year none of the cementless tibias and 30% of the cemented tibias had complete radiolucencies. One out of 31 cementless (3%) and 12 out of 31 cemented (39%) had partial radiolucencies. This difference between these two groups was high significant (p< 0 0001). Conclusions: This study clearly demonstrates that the incidence of radiolucency beneath the tibial component is influenced by component design and method of fixation. With identical designs of tibial component none of the cementless components developed complete radiolucences whereas 30% of the cemented components did. We conclude that HA achieves better bone integration than cement


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_I | Pages 75 - 75
1 Jan 2011
Parratt MTR Miles J Gokaraju K Spiegelberg BGI Pollock RC Skinner JA Cannon SR Briggs TWR Blunn GW
Full Access

Introduction: Intramedullary cementless fixation of massive tumor prostheses was developed to combat the high incidence of aseptic loosening in a young population of tumor patients. Its use has also expanded to include reconstruction of failed major knee arthroplasty. Our system uses a hydroxyapatite coated titanium stem in conjunction with a hydroxyapatite collar to obtain fixation. Methods: We present a series of 72 patients (34 females, 38 males) with a mean follow-up of six years (2 months – 14 years). The mean age at the time of surgery was 17 (5 – 77). Within this group, 51 patients had osteosarcomas, 10 had giant cell tumors, eight had Ewing’s sarcoma and one each had malignant fibrous histiocytoma, spindle cell sarcoma and failed total knee arthroplasty. Non-invasive and minimally invasive growing prostheses were used in 33 patients. Results: Nine patients required revision of the prosthesis at a mean of 5.2 years; 5 for aseptic loosening and four for infection. Twelve patients died at a mean of 20 months (1 – 84) post-operatively. Radiological evidence demonstrated remodelling around both the stem and the collar. There was gap closure to the hydroxyapatite coated collar in cases where seating was not complete. Consistent loss of cortical bone around the mid-stem was noted in the first 12 months but remained stable beyond this time frame. Discussion: This study highlights our experience with cementless distal femoral endosprostheses. We demonstrate good results with regard to revision rate, gap closure and osseointegration


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_6 | Pages 12 - 12
1 Apr 2018
Lazennec J Kim Y Pour AE
Full Access

Introduction. Few studies are published about total hip arthroplasties (THA) in Parkinson's disease as it is often considered as a contraindication for hip replacement. THA for fracture is reported as a high complication rate surgery. Regarding bone quality these cases are assimilated to elderly patients and cemented implants are generally preferred. However, due to the improved length and quality of life, we face more potential indications for joint replacement. The aim of this study is to report our experience of cementless dual mobility implants for primary THAs for osteoarthrosis and THA revisions focusing on the risks and benefits of surgery. Material and methods. 65 THA were performed in 59 patients (34 men, 25 women, mean age 73 years, 55–79). Mean latest follow-up was 8,3 years (4–14). Indications were 42 primary THA (osteoarthrosis) and 21 revisions (11 recurrent dislocation, 6 acetabular PE wear, 4 femoral loosening). Surgical approach was always antero-lateral. All patients were implanted with the same dual mobility cementless cup. The same cementless corail-type stem was used for primary THA cases. All the cemenless implants were hydroxyapatite coated. The disability caused by the disease was classified according to Hoehn and Yahr. (19 stage 1, 21 stage 2,16 stage 3). Results. 2 patients were lost for follow-up before 2 years. general complications were 3 pulmonary infection, 7 urinary tract infection, 12 cognitive impairment and 2 sacral pressure ulcer. A post-op. wound infection (E Coli) required an early revision in 2 cases without secondary consequencies (7 and 9 years follow-up). We did not observe early or late THA dislocation except in one case at 9 years follow-up (intraprosthetic dislocation due to an increase of ilio psoas muscle retraction requiring a revision of the dual mobility mechanism). We did not observe loosening cases of the cementless cup. 4 patients fell and fractured the femur. The cementless cup was not affected. 10 patients died. Good to excellent pain relief was achieved in 53/57cases at 2 years and in 40/47 cases at latest follow-up. The progression of neurological disability was observed in most of cases. At the latest follow-up for the 47 remaining patients, we had 5 stage 1, 12 stage 2, 21 stage 3,9 stage 4. Discussion. According to literature infection and dislocation are the main concerns for THA in Parkinson patients. This study does not report any trauma cases; this may explain the rather good results on a mean follow-up to more than 8 years. Nevertheless progression of Parkinson's disease is the rule, with significant disability or even death (10 /57 cases). Cementless fixation is possible even on the acetabular side. The poor bone quality of these patients was not an argument against hydroxyapatite coated implants. Conclusion. THA in Parkinson's disease is a challenging surgery due to associated comorbidity. For all patients the functional status improved in the early follow-up and declined with the disease progression. Cementless dual mobility cups and femoral stems can be used with a very low rate of mechanical complication


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 67 - 67
1 Jan 2013
Liddle A Pandit H Jenkins C Price A Gill H Dodd C Murray D
Full Access

Unicompartmental Knee Replacement (UKR) is associated with fewer complications, faster recovery and better function than Total Knee Replacement (TKR). However, joint registries demonstrate a higher revision rate in UKR, limiting its use. Currently most UKRs are cemented and performed using a minimally invasive technique. In joint registries, common reasons for revision include aseptic loosening and pain. These problems could potentially be addressed by using cementless implants, which may provide more reliable fixation. The objectives of this study were to compare the quality of fixation (determined by the incidence and appearance of radiolucencies), and clinical outcomes of cemented and cementless UKR at five years. A randomised controlled trial was established with 63 knees (62 patients) randomised to either cemented (32 patients) or cementless UKR (30 patients). Fixation was assessed with fluoroscopic radiographs aligned to the bone-implant interface at one and five years. Outcome scores were collected pre-operatively and at one, two and five years, including Oxford Knee Score (OKS), American Knee Society Score, objective and functional (AKSS-O/F) and Tegner Activity Scale (TAS), expressed as absolute scores and 0–5 year change (δ) scores. Four patients died during the study period. There were no revisions. Mean operative time was 11 minutes shorter in the cementless group (p=0.029). At five years, there was no significant difference in any outcome measure except AKSS-F and δAKSS-F which were significantly better in the cementless group (both p=0.003). There were no femoral radiolucencies in either group. There were significantly more tibial radiolucencies in the cemented group (20/30 vs 2/27, p< 0.001). There were nine complete radiolucencies in the cemented group and none in the cementless group (p< 0.001). Cementless fixation provides improved fixation at five years compared to cemented fixation in UKR, maintaining equivalent or superior clinical outcomes with a shorter operative time and no increase in complications


The Bone & Joint Journal
Vol. 103-B, Issue 7 Supple B | Pages 33 - 37
1 Jul 2021
Ennin KA Elsharkawy KA Dasgupta S Emerson RH

Aims

To achieve the functional benefits of the direct anterior (DA) approach and the fixation benefits of cemented replacement, this study combined the two techniques posing the following questions: does the limited access of the DA approach adversely affect the cement technique?; and does such a cementing technique reduce the incidence of cementless complications?

Methods

A consecutive series of 341 patients (360 hips) receiving the DA approach between 2016 and 2018 were reviewed. There were 203 cementless stems and 157 cemented stems. Mean age was 75 years (70 to 86) in the cementless group and 76 years (52 to 94) in the cemented group, with 239 (70%) females in the whole series. Femoral complications were compared between the two groups. Mean follow-up was 1.5 years (0.1 to 4.4) for patients in the cementless group and 1.3 years (0.0 to 3.9) for patients in the cemented group.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 139 - 139
1 Mar 2009
Schütz U Puhl W
Full Access

Introduction: The new anatomical adapted stem system OptanTM (Zimmer) is presented, showing the first mid-term-results for cemented and cementless fixation. Its cross-section in the proximal area corresponds with its antetorsion, anteversion and helitorsion, to the 3D-morphology of the proximal femur. Material and Methods: 313 Optan stems (175 cemented, 148 cementless) were implanted in 306 patients (mean age 62.1 y. (20–74 y.), m/f-ratio 0,8). The clinical and radiological parameters for calculation of Harris Hip Score (HHS), Merle d’Aubigné (MD), WOMAC and periprosthetic bone reaction (Gruen et al.) were recorded. An implant migration analysis using two different biplanar radiographic digital measurement systems (DMA, UMA) was done also. Results: The clinical results for latest follow up examination (5 and more y.p.o.) for cementless (cemented) Optan are: HHS mean (m) 97.6, standard deviation (SD) 7.32 (m 95.1, SD 9.85), MD m 17.6, SD 1.04 (m 17.1, SD 1.48), WOMAC m 1.44, SD 1.56 (m 1.75, SD 1.62). Cemented implantation shows a stable radiographic follow up regarding full cement mantle without any periprosthetic bone adaptations. The SD for the varus-valgus angle rises proportional to the thickness of the cement layer. Only little flattening of the calcar cortical bone (Z7b) could be seen in both, cemented and cementless Optan 2–3 years p.o.. No stem migration was evident in both fixation principles. No relevant osteolyses and cortical bone hypertrophies could be seen. 12 dislocations (closed reposition), 2 femoral fissures (all while cementless fixation), 2 septic loosenings and 1 aseptic loosening were documented till now. Radiographic results of cementless stem show a low rate (29,1%) of secondary endostal reactive line formation in the distal part of the stem (Z3,4,5) beginning 6–12 month postoperative, especially when drilling of femoral bone canal was done. When the distal part of the stem (Z3,5) was fixed directly to cortical bone little hypertrophy of the cortical bone gets relevant 4–5 years p.o. in a few cases. Conclusions: Compared with other anatomical stems the cementless Optan shows excellent midterm results. The clinical results of the cemented fixation are not quite so good, this may be related to the older mean age of the patients with cemented stem fixation. Among other things, the development of the Optan-stem had the aim, to make an interoperative change of fixation technique easier. Using the same stem design the decision about the fixation type can be made intraoperatively in the last second


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_IV | Pages 541 - 541
1 Oct 2010
Pandit H Beard D Dodd C Goodfellow J Jenkins C Murray D Price A
Full Access

Introduction: Most unicompartmental knee replacements (UKRs) employ cement for fixation of the prosthetic components to the bone. The information in the literature about the relative merits of cemented and cementless UKR is contradictory, with some favouring cementless fixation while others favouring cemented fixation. There is concern about the radiolucency which frequently develops around the tibial component with cemented fixations. The exact cause of the occurrence of radiolucency is unknown but according to some, it may suggest suboptimal fixation. Method: Following ethical approval, 62 patients with medial OA were randomised to receive either cemented (n=31) or cementless components (n=31). All patients underwent identical surgical procedure with either a cemented or cementless Oxford UKR. Patients were assessed clinically and radiologically. The x-rays were taken with an image intensifier (I.I.). The position of the I.I. was adjusted until it was perfectly aligned with the tibial bone-implant interface thereby allowing accurate assessment of presence and extent of the radiolucency. Results: The patients in the two groups were well matched. There was no significant difference in the clinical scores between the two groups. The mean OKS for the cemented group was 40 (± 8.3) and 42 (± 4.6) for cementless group. Narrow radiolucent lines were seen at the bone-implant interfaces of 75% of the cemented tibial components; partial in 43% and complete in 32%. In the cementless implants, partial radiolucencies were seen in 7% and complete radiolucencies in none. The differences are statistically highly significant (p< 0.0001) and imply satisfactory bone ingrowth into the cementless implants. Conclusions: The method of fixation influences the incidence of radiolucency. With identical designs, no patient with cementless components developed any complete radiolucency. The observation raises the question as to whether cementless rather than cemented components should be routinely used for UKR


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 17 - 17
7 Aug 2023
Arthur L Ghosh P Mohammad H Campi S Murray D Mellon S
Full Access

Abstract

Introduction

The Oxford Unicompartmental Knee Replacement's (OUKR's) fully-congruent design minimises polyethylene wear. Consequently, wear is a rare failure mechanism. Phase-3 OUKR linear wear at 5 years was higher than previous OUKR phases, but very low compared to fixed-bearing UKRs. This study aimed to measure OUKR bearing wear at 10 years and investigate factors that may affect wear.

Methodology

Bearing thickness for 39 OUKRs from a randomised study was calculated using radiostereometric analysis at regular intervals up to 10 years. Data for 39 and 29 OUKRs was available at 5 and 10 years, respectively. As creep occurs early, wear rate was calculated using linear regression between 6 months and 10 years. Relationships between wear and patient factors, fixation method, Oxford Knee Score (OKS), bearing position, and component position were analysed.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11_Supple_A | Pages 82 - 84
1 Nov 2012
Ranawat CS Meftah M Windsor EN Ranawat AS

There has been a recent increase in interest for non-cemented fixation in total knee arthroplasty (TKA), however the superiority of cement fixation is an ongoing debate.

Whereas the results based on Level III and IV evidence show similar survivorship rates between the two types of fixation, Level I and II evidence strongly support cemented fixation. United Kingdom, Australia, Sweden, and New Zealand registry data show lower failure rates and greater usage of cemented than non-cemented fixation. Case series studies have also indicated greater functional outcomes and lower revision rates among cemented TKAs. Non-cemented fixation involves more patellofemoral complications, including increased susceptibility to wear due to a thinner polyethylene bearing on the cementless metal-backed component. The combination of results from registry data, prospective randomised studies, and meta-analyses support the current superiority of cemented fixation in TKAs.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11_Supple_A | Pages 85 - 89
1 Nov 2012
Drexler M Dwyer T Marmor M Abolghasemian M Sternheim A Cameron HU

In this study we present our experience with four generations of uncemented total knee arthroplasty (TKA) from Smith & Nephew: Tricon M, Tricon LS, Tricon II and Profix, focusing on the failure rates correlating with each design change. Beginning in 1984, 380 Tricon M, 435 Tricon LS, 305 Tricon 2 and 588 Profix were implanted by the senior author. The rate of revision for loosening was 1.1% for the Tricon M, 1.1% for the Tricon LS, 0.5% for the Tricon 2 with a HA coated tibial component, and 1.3% for the Profix TKA. No loosening of the femoral component was seen with the Tricon M, Tricon LS or Tricon 2, with no loosening seen of the tibial component with the Profix TKA. Regarding revision for wear, the incidence was 13.1% for the Tricon M, 6.6% for the Tricon LS, 2.3% for the Tricon 2, and 0% for the Profix. These results demonstrate that improvements in the design of uncemented components, including increased polyethylene thickness, improved polyethylene quality, and the introduction of hydroxyapatite coating, has improved the outcomes of uncemented TKA over time.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_15 | Pages 8 - 8
1 Aug 2017
Seitz W
Full Access

Experience has demonstrated in the hip and knee, related to total joint replacement arthroplasty, polymethyl methacrylate cement fixation can provide problems in terms of loosening, fragmentation, particulate wear and ultimate failure. These same problems have been recognised in total shoulder arthroplasty related to cement fixation of the glenoid. While cement fixation of the humeral component has proven much less problematic, there has been a swelling towards avoidance of using cement to secure the humeral component for fear of difficulty if revision is required. Surprisingly, with the high incidence of lucent lines, bone resorption and frank loosening, representing the most common source of failure in total shoulder arthroplasty, cementless fixation of the glenoid has not been, until now, embraced. The advent of reverse total shoulder arthroplasty has demonstrated the ability for secure cementless fixation to provide long-lasting secure implant retention in implants which have inherently higher shear and stress forces passing through the implant/bone interface. In anatomic total shoulder arthroplasty a woven tantalum anchor (Trabecular Metal) has proven to demonstrate secure cementless fixation as well. This presentation will discuss the use of trabecular metal anchored glenoid implants with and without additional screw fixation for anatomic and convertible reverse arthroplasty baseplates. Avoidance of complications with successful long-lasting outcomes requires meticulous surgical attention to detail