Aims. Total hip arthroplasty (THA) is a very successful and cost-effective operation, yet debate continues about the optimum fixation philosophy in different age groups. The concept of the 'cementless paradox' and the UK 'Getting it Right First Time' initiative encourage increased use of cemented fixation due to purported lower revision rates, especially in elderly patients, and decreased cost. Methods. In a high-volume, tertiary referral centre, we identified 10,112 THAs from a prospectively collected database, including 1,699 cemented THAs, 5,782 hybrid THAs, and 2,631
The clinical success of THA is accepted, however wide variation in implant usage and outcomes is reported across the world. The Getting It Right First Time initiative in the UK has recommended increased use of cemented constructs in patients over 70. A clear clinical directive has been proposed aiming to reduce revision rates, improve outcomes and increase cost effectiveness. This study compares the outcomes of cemented, hybrid and cementless THA from a high-volume single center at long-term follow-up. A prospective database identified 1,699 cemented, 5,782 hybrid and 2,631
Aims. Registry studies on modified acetabular polyethylene (PE) liner designs are limited. We investigated the influence of standard and modified PE acetabular liner designs on the revision rate for mechanical complications in primary cementless total hip arthroplasty (THA). Methods. We analyzed 151,096 primary
Aims. Adult patients with history of childhood infection pose a surgical challenge for total hip arthroplasty (THA) due to distorted bony anatomy, soft-tissue contractures, risk of reinfection, and relatively younger age. Therefore, the purpose of the present study was to determine clinical outcome, reinfection rate, and complications in patients with septic sequelae after THA. Methods. A retrospective analysis was conducted of 91
Aims: Limb length discrepancy is a recognised complication of total hip arthroplasty (THA).
Second-generation metal-on-metal bearings have been used since the late 1980s as alternative bearings to eliminate aseptic loosening due to polyethylene wear. This study is the first with a long term follow-up for Meteasul, (Zimmer GmbH, Winterthur, Switzerland) metal on metal (MoM) hip replacement; in literature most of the studies have a mean follow-up of 7 years. Metasul showed better performances than other MoM couplings, with a low failure rate at long term follow-up and low revision rate for aspetic loosening. The aim of the present study was to evaluate the long-term results of a series of Metasul implanted between January 1993 and July 1997. 145
The fourth generation Delta ceramic, in which zirconia is incorporated into the alumina matrix, was developed to provide improved fracture toughness and wear characteristics. The purpose of this study was to evaluate the minimum 5-year outcomes and bearing-specific complications in a single surgeon series of Delta ceramic-on-ceramic total hip arthroplasties (THAs). We retrospectively analysed 667 patients (749 hips) who underwent
Ceramic-on-ceramic bearings provide a solution to the osteolysis seen with traditional metal-on-polyethylene bearings. Sporadic reports of ceramic breakage and squeaking concern some surgeons and this bearing combination can show in vivo signs of edge loading wear which was not predicted from in vitro studies. Taper damage or debris in the taper between the ceramic and metal may lead to breakage of either a ceramic head or insert. Fastidious surgical technique may help to minimise the risk of ceramic breakage. Squeaking is usually a benign complication, most frequently occurring when the hip is fully flexed. Rarely, it can occur with each step of walking when it can be sufficiently troublesome to require revision surgery. The etiology of squeaking is multifactorial in origin. Taller, heavier and younger patients with higher activity levels are more prone to hips that squeak. Cup version and inclination are also relevant factors. Osteolysis following metal-on-UHMW polyethylene Total Hip Arthroplasty (THA) is well reported. Earlier generation ceramic-on-ceramic bearings did produce some osteolysis, but in flawed implants. As third and now fourth generation ceramic THAs come into mid- and long-term service, the orthopaedic community has begun to see reports of high survival rates and very low incidence of osteolysis in these bearings. The technique used by radiologists for identifying the nature of lesions on Computed Tomography (CT) scan is the Hounsfield score which will identify the density of the tissue within the lucent area. Commonly the radiologist will have no access to previous imaging, especially pre-operative imaging if a long time has elapsed. With such a low incidence of osteolysis in this patient group, what, then, should a surgeon do on receiving a CT report on a ceramic-on-ceramic THA, which states there is osteolysis? This retrospective review aims to determine the accuracy of CT in identifying true osteolysis in a cohort of long-term third generation ceramic-on-ceramic uncemented hip arthroplasties in our department. Pelvic CT scans were performed on the first 27 patients from a cohort of 301 patients undergoing 15-year review with third generation alumina-alumina
Intra-operative fractures of the femur are on the rise mainly due to the increased use of cementless implants and the desire to get a tight press fit. The prevalence has been reported to be between 1–5% in
Introduction. The optimal bearing for hip arthroplasty is still a matter of debate. in younger and more active patients ceramic-on-polyethylene (CoP) bearings are frequently chosen over metal-on-polyethylene (MoP) bearings to reduce wear and increase biocompatibility. However, the fracture risk of ceramic heads is higher than that of metal heads. This can cause serious issue, as ceramic fractures pose a serious complication often necessitating major revision surgery – a complication more frequently seen in ceramic-on-ceramic bearings. To date, there are no long-term data (> 20 years of follow-up) reporting fracture rates of the ceramic femoral heads in CoP bearings. Patients and Methods. We retrospectively evaluated the clinical and radiographic results of 348
The purpose of this study was to evaluate in vivo fit and fill analysis of tapered wedge-type stem in total hip arthroplasty (THA) with computed tomography (CT)-based navigation system. 100 THAs were all performed through the posterolateral approach, with patients in the lateral decubitus position. Each cohort of 50 consecutive primary
Total hip arthroplasty (THA) is frequently performed as a salvage procedure for the acetabular fracture when posttraumatic osteoarthritis, posttraumatic avascular necrosis, or fixation failure with subluxation develop. Special considerations for this situation include previous surgical exposure with dense scar tissue, the type and location of implants, the location and amount of heterotopic ossification, indolent infection, previous sciatic nerve palsy, and the pathoanatomy of existing acetabular defect. These factors can influence the choice of surgical exposure and the reconstructive method. The outcomes of THA after acetabular fracture are generally less favorable than those of the nontraumatic degenerative arthritis. Reason for this high failure is the low mean age and the high activity level of the patient. Other important reasons for failure include the problem of acetabular bone deficiency and compromised bone quality. We evaluated the results of cementless THA in patient who had previous acetabular fracture. We also compared this result with those of patients with posttraumatic avascular necrosis of the femoral head. Forty-five consecutive
Second-generation metal-on-metal bearings have been used since the late 1980s as alternative bearings to eliminate aseptic loosening due to polyethylene wear. The aim of the present study was to evaluate the long-term results of a series of Metasul (Zimmer GmbH, Winterthur, Switzerland) metal-on-metal total hip arthroplasty (THA). Between January 1993 and September 1996, 149
Background/Purpose. Total hip arthroplasties (THAs) with ceramic bearings are widely performed in young, active patients and thus, long-term outcome in these population is important. Moreover, clinical implication of noise, in which most studies focused on ‘squeaking’, remains controversial and one of concerns unsolved associated with the use of ceramic bearings. However, there is little literature regarding the long-term outcomes after THAs using these contemporary ceramic bearings in young patients. Therefore, we performed a long-term study with a minimum follow-up of . 1. 5 years after THAs using contemporary ceramic bearings in young patients with osteonecrosis of the femoral head (ONFH) less than fifty. Materials and Methods. Among sixty patients (71 hips) with a mean age of 39.1 years, 7 patients (7 hips) died and 4 patients (4 hips) were lost before 15-year follow-up. The remaining 60 hips were included in this study with an average follow-up period of 16.3 years (range, 15 to 18). All patients underwent cementless THA using a prosthesis of identical design and a 28-mm third-generation alumina head by single surgeon. The clinical evaluations included the modified Harris hip score (HHS), history of dislocation and noise around the hip joint: Noise was classified into squeaking, clicking, grinding and popping and evaluated at each follow-up. Snapping was excluded through physical examination or ultrasonography. Radiographic analysis was performed regarding notching on the neck of femoral component, loosening and osteolysis. Ceramic fracture and survivorship free from revision were also evaluated. Results. The mean Harris hip score improved from 55.3 to 95.5 points (range, 83 to 100) at the time of the final follow-up. Seventeen patients (34.7%) reported noise around the hip joint: “squeaking” in one and “clicking” in 16 patients. Notching on the neck of femoral component suggesting impingement between neck and ceramic liner was demonstrated in 9 hips (15%) at average of 6.9 years postoperatively and located at 2 to 3.5 mm distal to edge of ceramic head. Although no chip fracture of ceramic ‘liner’ occurred, notching was associated with “clicking” sound (p<0.01). One patient who reported clicking sound underwent a revision THA because of ceramic ‘head’ fracture. Loosening, osteolysis or dislocation was not observed in any hip and survivorship free from revision at 5 years was 98%. Conclusion.
Ceramic-on-ceramic bearings provide a solution to the osteolysis seen with traditional metal-on-polyethylene bearings. Sporadic reports of ceramic breakage and squeaking concern some surgeons and this bearing combination can show in vivo signs of edge loading wear which was not predicted from in vitro studies. Taper damage or debris in the taper between the ceramic and metal may lead to breakage of either a ceramic head or insert. Fastidious surgical technique may help to minimise the risk of ceramic breakage. Squeaking is usually a benign complication, most frequently occurring when the hip is fully flexed. Rarely, it can occur with each step of walking when it can be sufficiently troublesome to require revision surgery. The etiology of squeaking is multifactorial origin. Taller, heavier and younger patients with higher activity levels are more prone to hips that squeak. Cup version and inclination are also relevant factors. Fifty-five ceramic bearings revised at our center were collected over 12 years. Median time to revision was 2.7 years. Forty-six (84%) cases had edge loading wear. The median femoral head wear volume overall was 0.2mm. 3. /yr, for anterosuperior edge loading was 2.0mm. 3. /yr, and the median volumetric wear rate for posterior edge loading was 0.15mm. 3. /yr (p=0.005). Osteolysis following metal-on-polyethylene total hip arthroplasty (THA) is well reported. Earlier generation ceramic-on-ceramic bearings did produce some osteolysis, but in flawed implants. As 3rd and now 4th generation ceramic THAs come into mid- and long-term service, the orthopaedic community has begun to see reports of high survival rates and very low incidence of osteolysis in these bearings. The technique used by radiologists for identifying the nature of lesions on Computed Tomography (CT) scan is the Hounsfield score which will identify the density of the tissue within the lucent area. Commonly the radiologist will have no access to previous imaging, especially pre-operative imaging if a long time has elapsed. With such a low incidence of osteolysis in this patient group, what, then, should a surgeon do on receiving a CT report on a ceramic-on-ceramic THA, which states there is osteolysis? This retrospective review aims to determine the accuracy of CT in identifying true osteolysis in a cohort of long-term 3rd generation ceramic-on-ceramic uncemented hip arthroplasties in our department. Methods. Pelvic CT scans were performed on the first 27 patients from a cohort of 301 patients undergoing 15-year review with 3rd generation alumina-alumina
Introduction. Osteloysis following metal-on-UHMW polyethylene Total Hip Arthroplasty (THA) is well reported, as is lack of osteolysis following Ceramic-on-Ceramic (CoC)THA. Early ceramic failures did report some osteolysis, but in flawed implants. As 3rd and now 4th generation ceramic THAs come into mid- and long-term use, the orthopaedic community has begun to see reports of high survival rates and very low incidence of osteolysis in these bearings. Osteolysis reported after 3rd generation CoC THA often included metallosis due to neck rim impingement. In our department we have revised only 2 hips in over 6000 CoC THAs for osteolysis. Both had evidence of metallosis as well as ceramic wear. The technique used by Radiologists for identifying the nature of lesions on CT is the Hounsfield score which will identify the density of the tissue within the lucent area. It is common for radiologist to have no access to previous imaging, especially pre-operative imaging if a long time has elapsed. With such a low incidence of osteolysis in this patient group, what, then, should a surgeon do on receiving a CT report on a ceramic-on-ceramic THA which states there is osteolysis? Revision of such implants in elderly patients has a high risk of morbidity and mortality. Objectives. This retrospective review aims to determine the accuracy of CT in identifying true osteolysis in a cohort of long-term third generation ceramic-on-ceramic uncemented hip arthroplasties in our department. Methods. Pelvic CT scans were performed on the first 27 patients from a cohort of 301 patients undergoing 15 year review with 3rd generation alumina-alumina
Introduction. In order to reduce polyethylene wear and incidence of osteolysis, and improve the long-term durability of total hip arthroplasty (THA), highly cross-linked polyethylene was introduced for clinical use in substitution for conventional polyethylene. We performed 35
Objectives. The purpose of the present study was to describe the long-term results of THA for ONFH in patients with SLE. Methods. From 1994–2001, 18
Introduction. Acute infection following Total Hip Arthroplasty (THA) is a serious complication. It is commonly treated by irrigation and debridement (I&D) with component retention (exchange only the mobile parts of the joint - head and liner). However, the reported re-infection rate with the use of this approach remains high. We are reporting our experience in using single - stage revision arthroplasty in treating acute infection of THA. We hypothesized that the infection control rate after immediate early revision for acute infection of cementless implants is better than has been reported for I&D with exchange of mobile parts. Methods. From our infection arthroplasty database, we reviewed the outcome of 19 patients who had an acute infection (within 6 weeks) of cementless THA. Our management strategy includes I&D and single-stage (direct-exchange) revision arthroplasty followed by 6 weeks course of culture specific oral antibiotics. Results. Patients' average age was 64 year (39–85), M:F = 11:8. There were 13 primary and 6 revision
Introduction:. Although cementless total hip arthroplasty (THA) is well accepted, the optimal femoral component design remains unknown. Among early complications, loosening and periprosthetic fracture persist and are related to implant design. The purpose of this study is to compare the anatomic fit and early subsidence of two different stem designs: a modern, short taper-wedge design and a traditional fit-and-fill design. Methods:. A retrospective cohort study of 129 consecutive