Abstract
Total hip arthroplasty (THA) is frequently performed as a salvage procedure for the acetabular fracture when posttraumatic osteoarthritis, posttraumatic avascular necrosis, or fixation failure with subluxation develop. Special considerations for this situation include previous surgical exposure with dense scar tissue, the type and location of implants, the location and amount of heterotopic ossification, indolent infection, previous sciatic nerve palsy, and the pathoanatomy of existing acetabular defect. These factors can influence the choice of surgical exposure and the reconstructive method. The outcomes of THA after acetabular fracture are generally less favorable than those of the nontraumatic degenerative arthritis. Reason for this high failure is the low mean age and the high activity level of the patient. Other important reasons for failure include the problem of acetabular bone deficiency and compromised bone quality. We evaluated the results of cementless THA in patient who had previous acetabular fracture. We also compared this result with those of patients with posttraumatic avascular necrosis of the femoral head.
Forty-five consecutive cementless THAs were performed for the treatment of post-traumatic osteoarthritis after acetabular fracture between December 1993 and December 2008. Of these patients, 15 patients were died or lost to follow-up monitoring before the end of the minimum one year follow-up period. This left 30 patients (30 hips) as the subjects of our retrospective review. We evaluated the clinical and radiographic results of these patients and compared with the results of THA in patients with post-traumatic AVN of the femoral head which had without acetabular damage.
Two hips required revision of the cup secondary to early migration of the acetabular cup (1 hip) and postoperative deep infection (1 hip). There was no significant difference in clinical and radiographic results between two groups except implanted acetabular component size and required bone graft (p<0.05). The Kaplan-Meier ten-year survival rate, with revision as the end-point, was 90% and 96.7% with loosening of acetabular component as the end-point.
Our series suggested that compared with cemented components, uncemented sockets may improve the results of arthroplasty after previous acetabular fracture. In conclusion, cementless THA following acetabular fracture presents unique challenge to the surgeon, careful preoperative assessment and secure component fixation with proper bone grafting is essential to minimize problems.