Advertisement for orthosearch.org.uk
Results 1 - 20 of 53
Results per page:
The Bone & Joint Journal
Vol. 105-B, Issue 5 | Pages 511 - 517
1 May 2023
Petrie MJ Panchani S Al-Einzy M Partridge D Harrison TP Stockley I

Aims. The duration of systemic antibiotic treatment following first-stage revision surgery for periprosthetic joint infection (PJI) after total hip arthroplasty (THA) is contentious. Our philosophy is to perform an aggressive debridement, and to use a high local concentration of targeted antibiotics in cement beads and systemic prophylactic antibiotics alone. The aim of this study was to assess the success of this philosophy in the management of PJI of the hip using our two-stage protocol. Methods. The study involved a retrospective review of our prospectively collected database from which we identified all patients who underwent an intended two-stage revision for PJI of the hip. All patients had a diagnosis of PJI according to the major criteria of the Musculoskeletal Infection Society (MSIS) 2013, a minimum five-year follow-up, and were assessed using the MSIS working group outcome-reporting tool. The outcomes were grouped into ‘successful’ or ‘unsuccessful’. Results. A total of 299 two-stage revision THAs in 289 patients met the inclusion criteria, of whom 258 (86%) proceeded to second-stage surgery. Their mean age was 68.1 years (28 to 92). The median follow-up was 10.7 years (interquartile range (IQR) 6.3 to 15.0). A 91% success rate was seen in those patients who underwent reimplantation, decreasing to 86% when including those who did not proceed to reimplantation. The median duration of postoperative systemic antibiotics following the first stage was five days (IQR 5 to 9). There was no significant difference in outcome between those patients who were treated with antibiotics for ≤ 48 hours (p = 0.961) or ≤ five days (p = 0.376) compared with those who were treated with longer courses. Greater success rates were seen for Gram-positive PJIs (87%) than for Gram-negative (84%) and mixed-Gram PJIs (72%; p = 0.098). Conclusion. Aggressive surgical debridement with a high local concentration of targeted antibiotics at the time of first-stage revision surgery for PJI of the hip, without prolonged systemic antibiotics, provides a high rate of success, responsible antibiotic stewardship, and reduced hospital costs. Cite this article: Bone Joint J 2023;105-B(5):511–517


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 1 | Pages 70 - 72
1 Jan 2002
Taggart T Kerry RM Norman P Stockley I

Although the incidence of infection associated with hip and knee prostheses is low, with the increasing number of arthroplasties being carried out, the total number of such cases is increasing. The pattern of infecting organisms after total joint arthroplasty has changed and gentamicin-resistant organisms are becoming increasingly common. In conjunction with surgical debridement, vancomycin added to a bone-cement carrier can be very effective in the treatment of infection caused by such organisms.

We report the results of its use in proven deep infection in 26 hip and seven knee arthroplasties. After a mean follow-up of 67 months, 32 patients remained clinically and radiologically free from infection. There was one recurrence and positive second-stage cultures of uncertain significance in three other patients. Vancomycin is potentially very useful in the management of deep infection after arthroplasty.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_10 | Pages 24 - 24
1 Oct 2022
Petrie M Panchani S Einzy MA Partridge D Harrison T Stockley I
Full Access

Aim. The duration of systemic antibiotic therapy following first-stage surgery is contentious. Our Institution's philosophy is to perform an aggressive debridement, use high concentration targeted antibiotics through cement beads and systemic prophylactic antibiotics alone. In the presence of significant soft tissue infection or microbiological diagnostic uncertainty; systemic antibiotics may be prescribed for 5 days whilst awaiting tissue culture results. The aim of this study was to assess the success of our philosophy in the management of PJI of the hip using our two-stage protocol. Method. A retrospective review of our Institution's prospectively-collected database was performed to identify those patients who were planned to undergo a two-stage hip revision procedure for PJI. All patients had a confirmed diagnosis of PJI as per the major criteria of MSIS 2013, a minimum 5-years follow up and were assessed at the time of review using the MSIS working group outcome-reporting tool (2018). They were then grouped into “successful” or “unsuccessful” (suppressive antibiotics, further revision for infection, death within 1 year). Results. 299 intended two-stage hip revisions in 289 patients (6 repeat ipsilateral two-stage, 4 bilateral two-stage) met our inclusion criteria. 258 (86%) patients proceeded to 2. nd. stage surgery. Median follow up was 10.7 years. 91% success rate was observed for those patients who underwent reimplantation; dropping to 86% when including the patients who did not proceed to second stage surgery. The median duration of post-operative systemic antibiotics following first stage surgery was 5 days (IQR 5–9). No significant difference in outcome was observed in patients who received either; < / = 48 hours (86%; n=70) compared to > 48 hours antibiotics (86%; n=229; p=0.96) or </= 5 days of antibiotics (88%; n=202) compared to > 5 days antibiotics (82%; p=0.38). A significant majority had gram-positive (88%) infection with 30% being polymicrobial. Greater success rates were observed for gram-positive PJI (87%); than for gram-negative PJI (84%) and mixed Gram infection (72%; p=0.098). Conclusion. Aggressive surgical debridement with high concentration, targeted local antibiotic delivery at time of first stage hip surgery, without prolonged systemic antibiotics, provides a high rate of success, responsible antibiotic stewardship and reduced hospital costs


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_4 | Pages 8 - 8
1 Apr 2022
Petrie M Al-Einzy M Panchani S Partridge D Harrison T Stockley I
Full Access

The duration of systemic antibiotics following first-stage surgery is contentious. Our Institution's philosophy is to perform an aggressive debridement, high concentration of targeted antibiotics through cement beads and systemic prophylactic antibiotics alone. In the presence of significant soft tissue infection or microbiological diagnostic uncertainty; systemic antibiotics may be prescribed for 5 days whilst awaiting tissue culture results. The aim of this study was to assess the success of our philosophy for two-stage hip revision. A retrospective review of our Institution's prospective database was performed to identify all intended two-stage hip revision procedures for PJI. All patients had a confirmed PJI as per MSIS 2013 criteria, minimum 5-years follow up and outcomes according to the MSIS working group outcome-reporting tool; then grouped into “successful” or “unsuccessful” (suppressive antibiotics, further revision for infection, death within 1 year). 383 intended two-stage hip revisions were identified; of which 299 met our inclusion criteria, in 289 patients (6 repeat ipsilateral two-stage, 4 bilateral two-stage). Median follow up was 10.7 years (IQR 6.3 – 15.0). 258 (86%) patients proceeded to 2. nd. stage surgery. 91% success rate was observed for those patients who underwent reimplantation, although dropping to 86% when including the patients who did not proceed to second stage. The median duration of post-operative systemic antibiotics was 5 days (IQR 5–9). No significant difference was observed in patients who received either; < / = 48 hours (86%; n=70) compared to > 48 hours antibiotics (86%; n=229; p=0.96) or </= 5 days of antibiotics (88%; n=202) compared to > 5 days antibiotics (82%; p=0.38). A significant majority had gram-positive (88%) infection with 30% being polymicrobial. Greater success rates were observed with two-stage exchange or gram-positive PJI (86%); than for gram-negative PJI (81%) and polymicrobial infection (74%) (p=0.36). Fungal PJI was observed to have a significantly reduced rate of success (n=3; 33%; p=0.03). Aggressive surgical debridement with high concentration, targeted local antibiotic delivery at time of first stage to manage PJI of the hip provides a high rate of success, responsible antibiotic stewardship and reduced hospital costs


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 220 - 220
1 Mar 2013
Cho H Kim J
Full Access

Purpose. To analyze the effectiveness of a vancomycin impregnated calcium sulfate cement bead insertion after debridement (of) an acute-immediate stage infected hip arthroplasty. Materials and Methods. Between 2002 and 2008, 13 patients with documented acute-immediate stage infection of hip arthroplasty were reviewed and followed for at least two years postoperatively(average 4.3 years). The preoperative and postoperative clinical and radiologic findings and blood laboratory work were checked. All cases were performed through retention of the implant and massive debridement and saline irrigation. After that a vancomycin impregnated calcium sulfate cement beads was inserted. Results. After the first operation, the average interval for second operation was 27.7 days (17–37). At the second operation, the erythrocyte sediment rate and C-reactive protein were 150.97 mm/hr (34.6 ∼339.7 mm/hr) and 76.4 mg/L (41∼132 mg/L) respectively. Infectious organism were cultured and isolated. There were 5 cases of Methicillin resistant staphylococcus aureus (MRSA). In addition, results of an antibiotics sensitivity test were 8 cases of Vancomycin, and 5 cases of 3rd generation Cephalosporin. Radiologic results showed 10 cases with stable fixation on last follow-up (femoral stem) and 1 case of hip joint space narrowing, acetabular erosion. Conclusion. Vancomycin impregnated, calcium sulfate, cement bead insertion for an acute immediate infection of hip arthroplasty proved to be a useful method


The Bone & Joint Journal
Vol. 102-B, Issue 6 Supple A | Pages 158 - 162
1 Jun 2020
Griseti Q Jacquet C Sautet P Abdel MP Parratte S Ollivier M Argenson J

Aims. The aim of this study was to compare the ability of tantalum, 3D porous titanium, antibiotic-loaded bone cement, and smooth titanium alloy to inhibit staphylococci in an in vitro environment, based on the evaluation of the zone of inhibition (ZOI). The hypothesis was that there would be no significant difference in the inhibition of methicillin-sensitive or methicillin-resistant Staphylococcus aureus (MSSA/MRSA) between the two groups. Methods. A total of 30 beads made of three different materials (tantalum/3D porous titanium and smooth titanium alloy) were bathed for one hour in a solution of 1 g vancomycin in 20 ml of sterile water for injection (bath concentration: 50 mg/mL). Ten 1 cm. 3. cylinders of antibiotic-loaded cement were also created by mixing standard surgical cement with 1 g of vancomycin in standardized sterile moulds. The cylinders were then placed on agar plates inoculated with MSSA and MRSA. The ZOIs were measured each day and the cylinders were transferred onto a new inoculated plate. Results. For MSSA and MRSA, no inhibitory effect was found in the control group, and antibiotic-loaded smooth titanium alloy beads showed a short inhibitory effect until day 2. For MSSA, both tantalum and 3D porous titanium beads showed significantly larger mean ZOIs than cement beads (all p < 0.01) each day until day 7 for tantalum and until day 3 for 3D porous titanium. After six days, antibiotic-loaded cement had significantly larger mean ZOIs than the 3D porous titanium (p = 0.027), but no significant difference was found with tantalum (p = 0.082). For MRSA, both tantalum and 3D porous titanium beads had significantly larger mean ZOIs than antibiotic-loaded cement each day until day 6 for tantalum (all p < 0.01) and until day 3 for 3D porous titanium (all p < 0.04). Antibiotic-loaded cement had significantly larger mean ZOIs than tantalum and 3D porous titanium from day 7 to 9 (all p < 0.042). Conclusion. These results show that porous metal implants can deliver local antibiotics over slightly varying time frames based on in vitro analysis. Cite this article: Bone Joint J 2020;102-B(6 Supple A):158–162


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 35 - 35
1 Jul 2014
Gbejuade H Lovering A Hidalgo-Arroyo A Leeming J Webb J
Full Access

Summary Statement. Conventional culture techniques have poor sensitivity for detecting bacteria growing in biofilms, which can result in under-diagnosis of infections. Sonication of biofilm colonised orthopaedic biomaterials can render bacteria in biofilm more culturable, thereby improving diagnosis of orthopaedic implant infections. Introduction. Prosthetic joint infection (PJI) is a potentially devastating complication in arthroplasty. Biofilm formation is central to PJI offering protection to the contained bacteria against host defence system and antimicrobials. Orthopaedic biomaterials generally have a proclivity to biofilm colonisation. Conventional culture technique has a low sensitivity for detecting bacteria in biofilm. Sonication can disrupt bacteria biofilms aggregations and dislodge them from colonised surfaces, rendering them culturable and consequently improve the diagnosis of otherwise culture-negative PJI. We investigated the effect of ultrasonication on biofilms adherent to poylmethylmethacrylate PMMA cement. Method. Identical PMMA cement beads were aseptically prepared using 7mm bead templates. Each sample comprised of two beads and with multiple replicates made for each sample. Two proficient biofilm forming strains of Staphylococcus epidermidis (5179-R1 and 1457) were used for the experiments. Each set of cement sample was immersed in Brain Heart Infusion broth inoculated with a pre-culture of the chosen bacteria strains (final concentration approximately 4 × 10. 6. CFU/ml). All samples were then incubated for 24 hours at 37°C to allow for biofilm growth and colonisation of the cement surfaces, as well as for biofilm maturity. After incubation, each sample was washed twice with sterile phosphate buffer saline (PBS) to remove non-adherent and loosely adherent bacteria. The cement beads were transferred to a fresh sterile bottle at each stage of the experiment, while ensuring the maintenance of asepsis. After the final wash, 10ml of sterile PBS was added to the cement beads and each sample was sonicated for varying periods: 0min, 5min, 10min, 20min and 40min. Sonicate fluid were collected after each period of sonication, with which culture plates were inoculated for the purpose of viable bacteria counting. Results. The optimum sonication period was between 5min and10 min. The mean pre-sonication CFU/ml were 4.7 × 10. 5. and 8.3 × 10. 5. for bacteria strains 5179-R1 and 1457 respectively, while the mean CFU/ml after 10min of sonication were 1.4 × 10. 7. and 0.74 × 10. 7. for bacteria strains the respective bacteria strains. Discussion / Conclusion. Our study showed a significant increase (almost 100 fold) in bacteria culture yield following sonication. We were also able to demonstrate that the optimum duration for sonication (using comparable sonicators) was approximately 10min. Sonication was able to completely remove adherent bacteria from the surfaces of our cement samples allowing them to be cultured. Our result suggests that sonication of bone cement can be instrumental in improving the diagnosis of biofilm associated PJI


Bone & Joint Research
Vol. 10, Issue 2 | Pages 149 - 155
16 Feb 2021
Shiels SM Sgromolo NM Wenke JC

Aims. High-energy injuries can result in multiple complications, the most prevalent being infection. Vancomycin powder has been used with increasing frequency in orthopaedic trauma given its success in reducing infection following spine surgery. Additionally, large, traumatic injuries require wound coverage and management by dressings such as negative pressure wound therapy (NPWT). NPWT has been shown to decrease the ability of antibiotic cement beads to reduce infection, but its effect on antibiotic powder is not known. The goal of this study was to determine if NPWT reduces the efficacy of topically applied antibiotic powder. Methods. Complex musculoskeletal wounds were created in goats and inoculated with a strain of Staphylococcus aureus modified to emit light. Six hours after contaminating the wounds, imaging, irrigation, and debridement and treatment application were performed. Animals received either vancomycin powder with a wound pouch dressing or vancomycin powder with NPWT. Results. There were no differences in eradication of bacteria when vancomycin powder was used in combination with NPWT (4.5% of baseline) compared to vancomycin powder with a wound pouch dressing (1.7% of baseline) (p = 0.986), even though approximately 50% of the vancomycin was recovered in the NPWT exudate canister. Conclusion. The antimicrobial efficacy of the vancomycin powder was not diminished by the application of NPWT. These topical and locally applied therapies are potentially effective tools that can provide quick, simple treatments to prevent infection while providing coverage. By reducing the occurrence of infection, the recovery is shortened, leading to an overall improvement in quality of life. Cite this article: Bone Joint Res 2021;10(2):149–155


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_23 | Pages 34 - 34
1 Dec 2016
Gbejuade H Hidalgo-Arroy A Sayers A Leeming J Lovering A Blom A Webb J
Full Access

Aim. To evaluate the ability of different combinations of antibiotic loaded cement to inhibit bacteria growth and biofilm formation. Method. Cement beads were aseptically prepared using Palacos R (plain 40g PMMA cement) or Palacos R+G (40g PMMA cement containing industrially added 0.5g of gentamicin), with or without supplementary antibiotics as follows: Palacos R; Palacos R+G; Palacos R plus 1g / 2g daptomycin; Palacos R+G plus 1g / 2g of daptomycin; Palacos R plus 1g / 2g vancomcyin; and Palacos R+G plus 1g / 2g vancomycin. After production, each antibiotic loaded acrylic cement (ALAC) combination was allocated into two groups (group 1 and 2). The group 2 cement beads were initially eluted in broth at 37. o. C for 72hours then transferred to fresh broth containing a known concentration of bacteria. The group 1 samples were not eluted but directly immerse in culture broth containing bacteria. All samples were thereafter incubated at 37. o. C for 24 hours. After incubation, group 1 samples were visually assessed for bacterial growth, while for the group 2 samples, biofilm formation were quantified using ultrasonication and viable bacteria counting technique. Three proficient biofilm forming Staphylococcus epidermidis bacterial strains (1457, 1585-RA and 5179-R1) were used for all experiments and the bacteria counts were expressed as colony forming units / ml (CFU/ml). Results. In the group 1 samples, all the ALAC combinations were able to inhibit growth of all the three biofilm bacteria strains assessed except the gentamicin only samples in which biofilm growth were observed within 24hours. Meanwhile, in group 2, bacterial growth and biofilm formation by all three bacterial strains were observed on all the ALAC combinations, with the least biofilm formation being on the Palacos R+G plus 2g daptomycin combinations (mean CFU/ml: 1.04E +06) and the greatest on the gentamicin only cement (mean CFU/ml: 2.3E +07). Conclusions. Our study demonstrates that the highest antimicrobial activity of ALAC is seen in the first 24 hours. However, after 72 hours of antibiotic release, fresh bacterial exposure in fresh broth resulted in varying degrees of biofilm colonisation of all ALAC surfaces. Nonetheless, the overall biofilm formation was least on the gentamicin / daptomycin combinations and the results were statistically significant when compared to plain cement (p < 0.05, two tail t-test)


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 11 | Pages 1596 - 1599
1 Nov 2010
Song EK Seon JK Jeong MS

We describe a patient who developed a delayed-type hypersensitivity reaction to piperacillin/tazobactam in the cement beads and a spacer inserted at revision of total replacement of the left knee. We believe that this is the first report of such a problem. Our experience suggests that a delayed-type hypersensitivity reaction should be considered when a mixture of antibiotics such as piperacillin/tazobactam has been used in the bone cement, beads or spacer and the patient develops delayed symptoms of pain or painful paraesthesiae, fever, rash and abnormal laboratory findings in the absence of infection. The diagnosis was made when identical symptoms were induced by a provocation challenge test


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_11 | Pages 35 - 35
1 Oct 2019
Argenson J Ollivier M Sautet P Grisetti Q Abdel MP Parratte S
Full Access

Introduction. Periprosthetic joint infection (PJI) remains the main cause of failure in primary and revision total knee arthroplasties (TKAs). Local delivery of antibiotics, mainly antibiotic-loaded bone cement (ALBC), is commonly employed to prevent PJI. Over the past decade, tantalum and porous titanium have been successfully utilized as metaphyseal fixation devices to address bone loss and improve biologic fixation during revision TKA. However, no study has examined the antimicrobial properties compared to bone cement. The purpose of this study was to compare the ability of tantalum, 3D porous titanium, antibiotic-loaded bone cement (ALBC) and smooth titanium alloy (STA) to inhibit Staphylococci bacterial agents in an in vitro medium environment, based on the evaluation of the zone of inhibition (ZOI) and the antibacterial activity duration. Our study hypothesis was that we will found no significant difference between groups to inhibit Methicillin-Sensitive or Methicillin-Resistant Staphylococcus aureus (MSSA/MRSA) agents. Methods. Thirty beads made of 3 different materials (tantalum/ 3D porous titanium/ STA) were bathed during 1hour inside of a solution made of 1g vancomycin with 20-mL of sterile water for injection (bath concentration: 50 mg/mL). Ten 1cm. 3. cylinders were also created mixing standard surgical cement with 1g of Vancomycin in standardized sterile molds (ALBC beads). Finally, thirty beads made of tantalum/ 3D porous titanium/ STA were bathed in phosphate buffered saline solution to act as a control group. Cylinders were then placed on agar plates inoculated with MSSA and MRSA. Inhibition zone diameters were measured each day and cylinders were transferred onto a new inoculated plate. Inhibition zones were measured with a manual Vernier caliper and with automated software. The mean inhibition zones between groups were compared using the Wilcoxon Test. Results. The inter-class coefficient correlation values indicated an optimal intra-observer and inter-observer reproducibility for ZOI measurement (ICC 0.96 and ICC 0.98). For MSSA and MRSA, no inhibitory effect was found in the control group and antibiotic-loaded STA beads exhibited a short inhibitory effect until day 2. For MSSA, both tantalum and 3D porous titanium beads exhibited larger inhibition zones than cement beads (all p<0.01) each day until day 7 for tantalum and until day 3 for 3D porous titanium. After 6 days, ALBC presented larger inhibition zone than the 3D porous titanium, but no difference was found with tantalum. For MRSA, both tantalum and 3D porous titanium beads had significantly larger inhibition zones than ALBC each day until day 6 for tantalum (all p<0.01) and until day 3 for 3D porous titanium (all p<0.04). ALBC presented larger inhibition zone than tantalum and 3D porous titanium from day 7 to 9 (all p<0.04). Conclusion. Our results demonstrate that porous metal implants can deliver local antibiotics over slightly varying time frames based on our in vitro analysis. Antibiotic-impregnated tantalum and 3D porous titanium constructs exhibited superior antimicrobial properties when compared to STA. Future goals include impregnating porous metals with antibiotics for intraoperative use during revision TKA. For figures, tables, or references, please contact authors directly


The Bone & Joint Journal
Vol. 98-B, Issue 7 | Pages 976 - 983
1 Jul 2016
Streubel PN Simone JP Morrey BF Sanchez-Sotelo J Morrey ME

Aims. We describe the use of a protocol of irrigation and debridement (I& D) with retention of the implant for the treatment of periprosthetic infection of a total elbow arthroplasty (TEA). This may be an attractive alternative to staged re-implantation. . Patients and Methods. Between 1990 and 2010, 23 consecutive patients were treated in this way. Three were lost to follow-up leaving 20 patients (21 TEAs) in the study. There were six men and 14 women. Their mean age was 58 years (23 to 76). The protocol involved: component unlinking, irrigation and debridement (I& D), and the introduction of antibiotic laden cement beads; organism-specific intravenous antibiotics; repeat I& D and re-linkage of the implant if appropriate; long-term oral antibiotic therapy. . Results. The mean follow-up was 7.1 years (2 to 16). The infecting micro-organisms were Staphylococcus aureus in nine, coagulase-negative Staphylococcus in 13, Corynebacterium in three and other in six cases. Re-operations included three repeat staged I& Ds, two repeat superficial I& Ds and one fasciocutaneous forearm flap. One patient required removal of the implant due to persistent infection. All except three patients rated their pain as absent or mild. Outcome was rated as good or excellent in 15 patients (mean Mayo Elbow Performance Score 78 points, (5 to 100) with a mean flexion-extension arc of 103° (40° to 150°)). . Conclusion. A staged protocol can be successful in retaining stable components of an infected TEA. Function of the elbow may compare unfavourably to that after an uncomplicated TEA. Cite this article: Bone Joint J 2016;98-B:976–83


The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1321 - 1326
1 Nov 2024
Sanchez-Sotelo J

Periprosthetic joint infection represents a devastating complication after total elbow arthroplasty. Several measures can be implemented before, during, and after surgery to decrease infection rates, which exceed 5%. Debridement with antibiotics and implant retention has been reported to be successful in less than one-third of acute infections, but still plays a role. For elbows with well-fixed implants, staged retention seems to be equally successful as the more commonly performed two-stage reimplantation, both with a success rate of 70% to 80%. Permanent resection or even amputation are occasionally considered. Not uncommonly, a second-stage reimplantation requires complex reconstruction of the skeleton with allografts, and the extensor mechanism may also be deficient. Further developments are needed to improve our management of infection after elbow arthroplasty.

Cite this article: Bone Joint J 2024;106-B(11):1321–1326.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_11 | Pages 51 - 51
1 Jun 2016
Frew N Nichol T Smith T Stockley I
Full Access

Introduction. Vancomycin is commonly added to acrylic bone cement during revision arthroplasty surgery. Proprietary cement preparations containing vancomycin are available but significantly more expensive. We investigated whether the antibiotic elution and mechanical strength of ‘home-made’ vancomycin containing bone cement was comparable to commercial vancomycin-impregnated cement. Methods. A total of 18 cement discs of constant size, containing either proprietary CopalG+V. ®. ; or ‘home-made’ CopalR+G. ®. with vancomycin added by hand, were made. Each disc contained the same antibiotic quantities (0.5g gentamycin, 2g vancomycin) and was immersed in ammonium acetate buffer in a sealed container. Fluid from each container was sampled at eight time points over a two week period. The concentration of gentamicin and vancomycin in the fluid was analysed using high performance liquid chromatography mass spectrometry. The impact strength of each PMMA cement preparation was measured using a Charpy-type impact tester. Results. Highest peak antibiotic concentrations were observed from the ‘home-made’ vancomycin containing cement, added as in the operating theatre. Overall antibiotic elution was, five-fold (vancomycin) and two-fold (gentamicin), greater from the ‘home-made’ mix compared to commercially mixed cement. However the ‘home-made’ cements showed greater variation in elution kinetics compared to the commercial mix. Use of a vacuum during mixing had no significant effect on antibiotic elution in any of the samples. Impact strength testing showed no significant differences between the groups. Discussion. Our findings suggest the addition of 2g vancomycin powder to gentamicin-impregnated bone cement in theatre, significantly increases elution of both antibiotics, with no significant loss of strength, compared to commercially prepared cement. Conclusion. We have found no significant advantages of expensive off-the-shelf vancomycin-impregnated bone cement and recommend the addition of vancomycin powder by hand when making cement beads and spacers


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_5 | Pages 8 - 8
1 May 2015
Noor S Gilson A Mulhern K Swanson A Mony K Vanny V Gollogly J
Full Access

Introduction:. The developing world often lacks the resources to effectively treat the most serious injuries, potentially resulting in severe complications of orthopaedic trauma, including osteomyelitis following open fractures or surgical fracture treatment. Antibiotic cement beads are now a widely accepted method of delivering antibiotics locally to the infected area following trauma. This study is based in Cambodia, a low income country struggling to recover from a recent genocide. Aims:. This project studied the effectiveness of locally made antibiotic beads, analysing their effectiveness after being gas sterilised, packaged and kept in storage. Methods:. Different antibiotic beads were manufactured locally using Simplex cement and tested against MRSA bacteria grown from a case of osteomyelitis. Each antibiotic was tested before and after a process of gas sterilisation as well as later being tested after storage in packaging up to 42 days. Results:. The gentamicin, vancomycin, amikacin and ceftriaxone beads all inhibited growth of the MRSA on the TSB and agar plates, both before and after gas sterilisation. All four antibiotics continued to show similar zones of inhibition after 42 days of storage, with slight fluctuations from week to week. Conclusion:. The four antibiotic beads manufactured using limited resources and in the austere environment were all effective in inhibiting bacterial growth. The growth of MRSA was inhibited by the antibiotic beads. Gas sterilisation or storage at room temperature for up to 42 days did not adversely deteriorate the efficacy of the beads. The results show significant promise to produce beads with locally obtainable ingredients in an austere environment and improve cost effectiveness by storing them in a sterilised condition


Bone & Joint 360
Vol. 12, Issue 4 | Pages 13 - 16
1 Aug 2023

The August 2023 Hip & Pelvis Roundup360 looks at: Using machine learning to predict venous thromboembolism and major bleeding events following total joint arthroplasty; Antibiotic length in revision total hip arthroplasty; Preoperative colonization and worse outcomes; Short stem cemented total hip arthroplasty; What are the outcomes of one- versus two-stage revisions in the UK?; To cement or not to cement? The best approach in hemiarthroplasty; Similar re-revisions in cemented and cementless femoral revisions for periprosthetic femoral fractures in total hip arthroplasty; Are hip precautions still needed?


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_18 | Pages 12 - 12
1 Apr 2013
Gbejuade H Lovering A Blom A Webb J
Full Access

Prosthetic joint infection(PJI) still remains a concern in orthopaedic practice. Antibiotic-loaded acrylic-cement(ALAC) is a proven means of lowering the incidence of PJI. However, increasing antimicrobial resistance has complicated both prophylaxis and treatment, prompting the use of combination antimicrobial therapy, with the addition of vancomycin to gentamicin-containing ALAC commonly used. The new antimicrobial, daptomycin, has better activity than vancomycin and we studied its elution from ALAC in comparison with vancomycin, along with its impact on the co-elution of gentamicin. Cement beads were prepared from PalacosRG containing, 1g/2g daptomycin, 1g/2g vancomycin and without additional antibiotics. Six replicates of each combination were eluted in PBS at 37oC, at timed intervals, for up to 90days, the antibiotic loss was assessed using validated assays. The mean recovery of gentamicin after 90days was 1.1mg with half eluted within the first 6 hours. Recovery was significantly increased by 60% and 40% with addition of 1g&2g of daptomycin(two-tail t-test: p=0.004 and p=0.02), respectively. Although there was a slight increase in gentamicin recovery in vancomycin loaded samples, this was not statistically significant(p>0.05). The significant increases in gentamicin elution from Palacos RG when supplemented with daptomycin, along with a superior activity, may provide a better synergistic effect than PalacosRG supplemented with vancomycin in the management of PJI


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_3 | Pages 96 - 96
1 Jan 2016
Oe K Ueda N Nakamura T Okamoto N Ueda Y Iida H
Full Access

Introduction. Antibiotic-loaded acrylic cement (ALAC) is employed in the treatment or prevention of infected total hip arthroplasty (THA). We have administered vancomycin (VCM) as the ALAC for the treatment of THAs with methicillin-resistant Staphylococcus aureus, or for the prevention of THAs with high risks. This study aimed to evaluate the serum concentration of VCM from ALAC in THA or cement beads. Methods. Between December 2013 and February 2014, 16 hips (16 patients) underwent application of the ALAC including VCM at our institution. Two hips were used for the treatment of infection, in the first stage of two-staged revision THAs (i.e., cement beads). Two hips were used for the both treatment and prevention of infection, in one-staged revision THAs. Twelve hips were used for the prevention of infection, in aseptic revision THAs or primary THAs with high risks. Patients were classified into two groups depending on the VCM concentration of ALAC, as follows: high-dose group (2 hips), average 4.4% (3.8–5.0%); low-dose group (14 hips), average 1.6% (1.3–2.5%). The amount of VCM placed as ALAC into the hip was calculated by using the remaining ALAC. The serum concentration of VCM was evaluated at 1 day, 4 days, 7 days, and 28 days after surgery. Statistical analysis was performed by using the t-test, and the differences were considered significant when the p value was <0.05. Results. Average amount of VCM placed as ALAC was 3.5 g (3.1–4.0 g) and 0.9 g (0.3–2.0 g) in the high- and low-dose groups, respectively. The average serum concentration of VCM (μg/mL) was 2.5 and 1.1 on day 1, 2.8 and 1.2 on day 4, 2.3 and 1.1 on day 7, and 1.9 and 1.0 on day 28, in the high- and low-dose groups, respectively. There were significant differences in the high- and low-dose groups on all days. Conclusions. Although the serum concentration of VCM in the high-dose group is significantly increased compared to that in the low-dose group, it is always under the effective blood concentration (5–10 μg/mL) and seem to be clinically safe. Further, we confirmed the continuous effect of ALAC, including VCM, because they were detected at 28 days. However, careful continued follow-up and further evaluation will be required


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 199 - 199
1 Mar 2013
Hirose S Otsuka H Morishima T
Full Access

Introduction. We report our mid-term results and risk factors of a two-stage revision using impaction bone grafting for an infected hip replacement. Methods. A two-stage revision using impacted cancellous allografs and cement was performed in 13 patients (7 total hip replacements, 6 femoral head replacements) with confirmed infection. The mean age of the patients at first stage operation was 63 years (range, 45–84 years). In the first stage, local antibiotics were added to customized cement beads and/or a cement spacer after removal of all components and radical debridement. In the second stage, impaction grafting was done using the X-change system (Exeter). Results. Of the patients, 8 underwent multiple operations to obtain evidence that infection had been overcome in the first stage, and of them, 6 had infection due to methicillin-resistant Staphylococcus aureus (MRSA). The mean duration from first stage operation to second stage revision was 8 months (range, 3–17 months). Only one patient suffered re-infection due to MRSA after second stage revision, which was not the original infecting agent, and the other 12 patients had satisfactory radiological outcomes. The success rate was 92% at the mean follow-up of 4 years (range, 1–10 years) after revision. Conclusion. Allograft bone was shown to be useful for infected hip replacement with a considerable loss of bone stock. We considered that control of MRSA infection is a key factor for successful outcome


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 7 | Pages 962 - 965
1 Sep 2004
Ammon P Stockley I

A two-stage procedure was carried out on 57 patients with confirmed infection in a hip replacement. Allograft bone was used in the second stage. Pathogenic organisms were identified in all patients. In stage 1, the prosthesis was removed together with infected tissue. Antibiotics were added to customised cement beads. Systemic antibiotics were not used. At the second stage, 45 of the patients had either acetabular impaction grafting, femoral impaction grafting or a combination; 12 had a massive allograft. Eight patients suffered recurrent infection (14%), in six with the original infecting organism. The risk factors for re-infection were multiple previous procedures and highly resistant organisms. We believe that systemic antibiotic therapy should be considered for these patients. Allograft bone is shown to be a useful adjunct in most infected hip replacements with considerable loss of bone stock