Advertisement for orthosearch.org.uk
Results 1 - 20 of 81
Results per page:
Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 467 - 467
1 Sep 2012
Ding M Overgaard S
Full Access

Introduction. Osteoporosis (OP), osteoarthrosis (OA), and rheumatoid arthritis (RA) are the most common age-related degenerative bone diseases, and major public health problems in terms of enormous amount of economic cost. RA is considered as a major cause of secondary osteoporosis. At late stage, OP often leads to skeletal fractures, and OA and RA result in severe joint disability. Over the last a few decades, much significant research on the properties has been carried out on these diseases, however, a detailed comparison of the microarchitecture of cancellous bones of these diseases is not available. In this study, we investigated three-dimensional (3-D) microarchitectural properties of OP, OA and RA cancellous bone. We hypothesized that there were significant differences in microarchitecture among OP, OA and RA bone tissues that might lead to different bone quality. Materials and Method. Twenty OP, fifty OA, and twelve RA femur heads were harvested from patients undergone total hip replacement surgery. Cubic cancellous bone samples (8∗8∗8 mm3) were prepared and scanned with a high resolution microtomographic system (vivaCT 40, Scanco Medical AG., Brüttisellen, Switzerland). Then micro-CT images were segmented using individual thresholds to obtain accurate 3-D data sets. Detailed microarchitectural properties were evaluated based on novel unbiased, model-free 3-D methods. For statistical analysis, one-way ANOVA was used, and a p<0.05 was considered significant. Results. Significant differences in the microarchitecture of cancellous bone were observed among the OP, OA and RA groups. Compared with the other groups, OP cancellous bone had lowest density, thinner, typical rod-like structure and less connectivity (all p<0.01). Interestingly, there were no significant differences in the microarchitectural properties measured between the OA and RA cancellous bones. Both OA and RA cancellous bones had significant higher bone volume fraction and were thicker, typical plate-like structure compared with the OP group (all p<0.01), even though there was clearly bone erosion observed in RA cancellous bone. Discussion. Quantification of the alterations in bone properties and quality will help to gain more insights into the pathogenesis of degenerative bone diseases and to target and develop novel approaches for the intervention and treatment, and for the design, fixation and durability of total joint prosthesis. Our study demonstrated that there were significant differences in the microarchitecture of the OP, OA and RA femur head cancellous bone. The OA and RA cancellous bone had similar bone density and microarchitecture despite apparent bone erosion in the RA cancellous bone. These results from femur head did not support the traditional notion that RA and OP had similar low bone density. Thus, whether femur head bone tissues from these diseases have similar bone collagen, mineral and mechanical properties, more importantly bone quality, should be clarified in the future


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 401 - 401
1 Sep 2012
Aurégan J Bérot M Magoariec H Hoc T Bégué T Hannouche D Zadegan F Petite H Bensidhoum M
Full Access

Introduction. Osteoporosis is a metabolic disease of the bone responsible for a loss of bone resistance and an increase in fracture risk. World Health Organization (WHO) estimations are about 6.3 millions of femoral neck fractures in the world by 2050. These estimations make osteoporosis a real problem in term of public health. Knowledge in biological tissues mechanical behaviour and its evolution with age are important for the design of diagnosis and therapeutic tools. From the mechanical aspect, bone resistance is dependent on bone density, bone architecture and bone tissue quality. If the importance of bone density and bone architecture has been well explored, the bone tissue quality still remains unstudied because of the lack of biomechanical tools suitable for testing bone at this microscopic dimension. Therefore the goal of this study is to estimate the osteoporotic cancellous bone tissue mechanical behaviour at its microscopic scale, using an approach coupling mechanical assays and digital reconstruction. Materials and methods. The experimental study is based on cancellous bone tissue extracted from human femoral head. Forty 8mm diameters bone cylinders have been removed from femoral head explanted after a femoral neck fracture treated by arthroplasty. These cylinders have been submitted to a digitally controlled compressive trial. Before and after the trials, microscanner analyses with an 8 μm spatial resolution have been realized in order to determine the micro structural parameters. The cylinders have been rebuilt with the digital model-building in order to estimate the mechanical behaviour and the bone quality. Results. The results will be presented from a macroscopic and microscopic point of view and will show the relationship between gender and age of the patients. At the macroscopic scale, we will look at that apparent young modulus heterogeneity and the cracking strength. At the microscopic scale, we will confirm that the cancellous bone tissue mechanical behaviour is close to the Haversian bone tissue mechanical behaviour. Finally, the parametric study will permit us to point out the main microstructural components influencing cancellous bone tissue quality. Conclusion. This study allows a precise estimation of the osteoporotic cancellous bone tissue mechanical behaviour. It seems to be a great step in the understanding of this disease and it could probably lead to great improvements in the diagnosis, prognostic, medical and surgical approaches of osteoporosis


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 3 | Pages 428 - 432
1 May 1997
Cannegieter DM Juttmann JW

We present a prospective study of the treatment of 32 unstable Colles’ fractures by external fixation and cancellous grafting with minimal exposure. We inserted an external fixator between the radius and the second metacarpal, and maintained ligamentotaxis for five weeks. In 27 patients the result was good or excellent, but five fractures healed with malunion. All patients made a satisfactory functional recovery. At a mean follow-up of three years (1 to 5) after injury none had pain in the wrist and all were satisfied with the result. The average grip strength was 95% of normal. Seven patients had algodystrophy with mild impairment of finger movements in four. We conclude that the combination of cancellous grafting and external fixation is effective for the treatment of unstable Colles’ fractures


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 393 - 393
1 Sep 2012
Zlowodzki M Wijdicks C Armitage B Cole P
Full Access

Introduction. Femoral neck fractures are a large clinical and economical problem. One of the most common fixation options for femoral neck fractures are multiple cancellous screws. A previous clinical study has shown the lack of washers to be the single largest predictor of fixation failure in the treatment of femoral neck fractures with cancellous screws. This finding was somewhat surprising as washers do not prevent the screws from backing out and do not provide any increase resistance to varus collapse. Therefore a follow-up biomechanical study was designed to test this observation. The purpose was to evaluate the maximal insertional torque of screws in osteoporotic bone with and without washers. We hypothesized that the lateral cortex of an osteoporotic proximal femur does not provide sufficient counter resistance for the screw heads to obtain maximum torque upon screw insertion in the femoral head and that the use of washers would increase screw purchase by providing a larger rigid surface area and subsequent higher counter resistance thereby allowing a higher maximal screw insertion torque. Methods. We used eight matched pairs of osteoporotic fresh-frozen human cadaveric femurs (age >70 years, all female). Two screws each were inserted in each femur either with or without a washer and maximal insertional torque was measured using a 50 Nm torque transducer. The testing was performed using a customized device which allowed the torque transducer to apply a constant axial force and torque speed to the screws. A paired Student's t-test was used to compare the maximal screw insertional torque of screws with washers versus screws without washers in matched pairs. Results. Fifteen out of 16 times the maximal screw insertional torque was higher when a washer was used. The average maximal torque with a washer was 5.1 Newtonmeter (Nm) compared to 3.1 Nm without a washer (p<0.001). Conclusion. We conclude that the addition of washers increases the maximal insertion torque of cancellous screws in the treatment of osteoporotic femoral neck fractures by providing counter resistance to the screw heads at an otherwise weak lateral cortex. We have demonstrated that the washer prevents the screw heads from penetrating the lateral cortex and provides for an improved purchase of the screws in the femoral head. As a clinical reference value for interpretation of this data, the limit of torque limiting screw drivers used with locking plates is set between 4 and 6 Nm. Therefore the difference in insertion torques likely represents clinically relevant values. Since there is no apparent disadvantage in the use of washers and they are inexpensive and readily available even in less developed countries, we advocate for their routine use until larger clinical studies disprove their efficacy


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_16 | Pages 16 - 16
1 Apr 2013
Grosso MJ Courtland HW Yang X Sutherland J Fahlgren A Ross PF van der Meulen MMC Bostrom MP
Full Access

Improving periprosthetic bone is essential for implant fixation and reducing peri-implant fracture risk. This studied examined the individual and combined effects of iPTH and mechanical loading at the cellular, molecular, and tissue level for periprosthetic cancellous bone. Adult rabbits had a porous titanium implant inserted bilaterally on the cancellous bone beneath a mechanical loading device on the distal lateral femur. The right femur was loaded daily, the left femur received a sham loading device, and half of the rabbits received daily PTH. Periprosthetic bone was processed up to 28 days for qPCR, histology, and uCT analysis. We observed an increase in cellular and molecular markers of osteoblast activity and decrease in adipocytic markers for both treatments, with small additional effects in the combined group. Loading and iPTH led to a decrease and increase, respectively, in osteoclast number, acting through changes in RANKL/OPG expression. Changes in SOST and beta-catenin mRNA levels suggested an integral role for the Wnt pathway. We observed strong singular effects on BV/TV of both loading (1.53 fold) and iPTH (1.54 fold). Combined treatment showed a small additive effect on bone volume. In conclusion, loading and iPTH act through a pro-osteoblastic/anti-adipocytic response and through control of bone turnover via changes in the RANKL/OPG pathway. These changes led to a small additional, but not synergistic, increase in bone volume with the combined therapy


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 411 - 411
1 Sep 2012
Arumugam G Wraighte P Howard P Nanjayan S
Full Access

Introduction. Acetabular bone deficiency presents one of the most challenging problems during revision hip arthroplasty. A variety of surgical options and techniques are available including impaction bone grafting. We present our medium to long-term experience of 68 consecutive hips in 64 patients who had acetabular revision using impacted cancellous bone grafting with bone cement with a mean follow up of 10.5 ±3.75) years (range 5.1 to 17.7 years). Methods. Patients' undergoing acetabular bone grafting during revision hip arthroplasty prior to insertion of a cemented cup between 1993 and 2000 were evaluated. Pre-operative, immediate post-operative, 1 year post-op and final follow-up radiographs were evaluated. The pre-operative bone loss was graded according to the AAOS and Paprosky classifications. The presence of radiolucencies, alignment and incorporation of bone graft were evaluated. The Harris Hip Score (HHS) was used to assess clinical outcome. 13 patients who were unable to attend the department were contacted for a telephone interview. Analysis of the Data was carried out using SPSS17 [SPSS Inc. Chicago, Illinois]. Results. 64 consecutive patients (68 hips) were evaluated with an average age of 69.9 (± 10.24) years. At the mean follow up of 10.5 years [5.1–17.7 years] Kaplan-Meier survivorship analysis predicted a rate of survival of the acetabular component of 95.5% (95% confidence interval (CI) 92 to 99) at 10 years, with revision for any reason as the endpoint. The median Harris hip score at final follow up was 79.5 [IQR 67.9–80.45]. Neither the extent of initial defect or acetabular inclination were related to clinical outcome or predicted further revision. Progression of the radiololucent zones between the cement bone interface was a predictor of loosening and further revision. Discussion. Our findings have shown that acetabular revision using impacted cancellous bone graft and a cemented acetabular component remains a reliable and successful technique for patients with poor femoral bone stock


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 555 - 555
1 Sep 2012
Starks I Frost A Wall P Lim J
Full Access

The management of pelvic fractures remains a challenging problem for orthopaedic surgeons. The prompt recognition of unstable fracture patterns is important in reducing mortality and morbidity. It is perceived wisdom that a fracture of the transverse process of L5 is a predictor of pelvic fracture instability. There is a paucity of evidence in the literature to support this belief. The aim of our study was to determine if a fracture of the transverse process of L5 was a predictor of pelvic fracture instability.

The Hospital Trauma database was reviewed. Between 2006 and 2009, 65 pelvic fractures were identified. They were classified according to the Burgess and Young classification. There were 37 stable and 28 unstable fractures. 14 patients had an associated fracture of the transverse process of L5; 9 were associated with an unstable fracture pattern. The odds ratio was 3; the relative risk 1.7.

A fracture of the transverse process of L5 is associated with an increased risk of pelvic fracture instability. Its presence should alert the attending physicians to the possibility of an unstable injury.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_12 | Pages 10 - 10
1 Jun 2016
Scott C Eaton M Nutton R Wade F Evans S Pankaj P
Full Access

25–40% of unicompartmental knee replacement (UKR) revisions are performed for unexplained pain possibly secondary to elevated proximal tibial bone strain. This study investigates the effect of tibial component metal backing and polyethylene thickness on cancellous bone strain in a finite element model (FEM) of a cemented fixed bearing medial UKR, validated using previously published acoustic emission data (AE). FEMs of composite tibiae implanted with an all-polyethylene tibial component (AP) and a metal backed one (MB) were created. Polyethylene of thickness 6–10mm in 2mm increments was loaded to a medial load of 2500N. The volume of cancellous bone exposed to <−3000 (pathological overloading) and <−7000 (failure limit) minimum principal (compressive) microstrain (µ∊) and >3000 and >7000 maximum principal (tensile) microstrain was measured. Linear regression analysis showed good correlation between measured AE hits and volume of cancellous bone elements with compressive strain <−3000µ∊: correlation coefficients (R= 0.947, R2 = 0.847), standard error of the estimate (12.6 AE hits) and percentage error (12.5%) (p<0.001). AP implants displayed greater cancellous bone strains than MB implants for all strain variables at all loads. Patterns of strain differed between implants: MB concentrations at the lateral edge; AP concentrations at the keel, peg and at the region of load application. AP implants had 2.2 (10mm) to 3.2 (6mm) times the volume of cancellous bone compressively strained <−7000µ∊ than the MB implants. Altering MB polyethylene insert thickness had no effect. We advocate using caution with all-polyethylene UKR implants especially in large or active patients where loads are higher


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 9 | Pages 1259 - 1264
1 Sep 2011
Wähnert D Windolf M Brianza S Rothstock S Radtke R Brighenti V Schwieger K

We investigated the static and cyclical strength of parallel and angulated locking plate screws using rigid polyurethane foam (0.32 g/cm. 3. ) and bovine cancellous bone blocks. Custom-made stainless steel plates with two conically threaded screw holes with different angulations (parallel, 10° and 20° divergent) and 5 mm self-tapping locking screws underwent pull-out and cyclical pull and bending tests. The bovine cancellous blocks were only subjected to static pull-out testing. We also performed finite element analysis for the static pull-out test of the parallel and 20° configurations. In both the foam model and the bovine cancellous bone we found the significantly highest pull-out force for the parallel constructs. In the finite element analysis there was a 47% more damage in the 20° divergent constructs than in the parallel configuration. Under cyclical loading, the mean number of cycles to failure was significantly higher for the parallel group, followed by the 10° and 20° divergent configurations. In our laboratory setting we clearly showed the biomechanical disadvantage of a diverging locking screw angle under static and cyclical loading


The Bone & Joint Journal
Vol. 106-B, Issue 6 | Pages 613 - 622
1 Jun 2024
Shen J Wei Z Wu H Wang X Wang S Wang G Luo F Xie Z

Aims

The aim of the present study was to assess the outcomes of the induced membrane technique (IMT) for the management of infected segmental bone defects, and to analyze predictive factors associated with unfavourable outcomes.

Methods

Between May 2012 and December 2020, 203 patients with infected segmental bone defects treated with the IMT were enrolled. The digital medical records of these patients were retrospectively analyzed. Factors associated with unfavourable outcomes were identified through logistic regression analysis.


Bone & Joint Open
Vol. 5, Issue 2 | Pages 147 - 153
19 Feb 2024
Hazra S Saha N Mallick SK Saraf A Kumar S Ghosh S Chandra M

Aims

Posterior column plating through the single anterior approach reduces the morbidity in acetabular fractures that require stabilization of both the columns. The aim of this study is to assess the effectiveness of posterior column plating through the anterior intrapelvic approach (AIP) in the management of acetabular fractures.

Methods

We retrospectively reviewed the data from R G Kar Medical College, Kolkata, India, from June 2018 to April 2023. Overall, there were 34 acetabulum fractures involving both columns managed by medial buttress plating of posterior column. The posterior column of the acetabular fracture was fixed through the AIP approach with buttress plate on medial surface of posterior column. Mean follow-up was 25 months (13 to 58). Accuracy of reduction and effectiveness of this technique were measured by assessing the Merle d’Aubigné score and Matta’s radiological grading at one year and at latest follow-up.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_33 | Pages 8 - 8
1 Sep 2013
Scott C Eaton M Nutton R Wade F Pankaj P Evans S
Full Access

Joint registries report that 25–40% of UKR revisions are performed for pain. Proximal tibial strain and microdamage are possible causes of this “unexplained” pain. The aim of this study was to examine the effect of UKR implant design and material on proximal tibial cortical strain and cancellous microdamage. Composite Sawbone tibias were implanted with cemented UKR components: 5 fixed bearing all-polyethylene (FB-AP), 5 fixed bearing metal backed (FB-MB), and 5 mobile bearing metal backed implants (MB-MB). Five intact tibias were used as controls. Tibias were loaded in 500N increments to 2500N. Cortical surface strain was measured using digital image correlation (DIC). Cancellous microdamage was measured using acoustic emission (AE), a technique which detects elastic waves produced by the rapid release of energy during microdamage events. DIC showed significant differences in anteromedial cortical strain between implants at 1500N and 2500N in the proximal 10mm only (p<0.001) with strain shielding in metal backed implants. AE showed significant differences in cancellous microdamage (AE hits), between implants at all loads (p=0.001). FB-AP implants displayed significantly more hits at all loads than both controls and metal backed implants (p<0.001). FB-AP implants also differed significantly by displaying AE hits on unloading (p=0.01), reflecting a lack of implant stiffness. Compared to controls, the FB-AP implant displayed 15x the total AE hits, the FB-MB 6x and the MB-MB 2.7x. All-polyethylene medial UKR implants are associated with greater cancellous bone microdamage than metal backed implants even at low loads


The Bone & Joint Journal
Vol. 106-B, Issue 4 | Pages 387 - 393
1 Apr 2024
Dean BJF Riley N Little C Sheehan W Gidwani S Brewster M Dhiman P Costa ML

Aims

There is a lack of published evidence relating to the rate of nonunion seen in occult scaphoid fractures, diagnosed only after MRI. This study reports the rate of delayed union and nonunion in a cohort of patients with MRI-detected acute scaphoid fractures.

Methods

This multicentre cohort study at eight centres in the UK included all patients with an acute scaphoid fracture diagnosed on MRI having presented acutely following wrist trauma with normal radiographs. Data were gathered retrospectively for a minimum of 12 months at each centre. The primary outcome measures were the rate of acute surgery, delayed union, and nonunion.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_3 | Pages 2 - 2
1 Feb 2020
Shields D Llopis-Hernandez V Jayawarna V Gonzales-Garcia C Marshall W Dalby M Salmeron-Sanchez M
Full Access

Osteoinductive bone substitutes are in their developmental infancy and a paucity of effective grafts options persists despite clinical demand. Bone mineral substitutes such as hydroxyapatite cause minimal biological activity when compared to osteoinductive systems present biological growth factors in order to drive bone regeneration. We have previously demonstrated the in-vitro efficacy of a bioengineered system at presenting growth factors at ultra low-doses. This study aimed to translate this growth factor delivery system towards a clinically applicable implant. Osteoinductive surfaces were engineered using plasma polymerisation of poly(ethyl acrylate) onto base materials followed by adsorption of fibronectin protein and subsequently growth factor (BMP-2). Biological activity following ethylene oxide (EO) sterilisation was evaluated using ELISAs targeted against BMP-2, cell differentiation studies and atomic force microscopy. Scaffolds were 3D printed using polycaprolactone/hydroxyapatite composites and mechanically tested using a linear compression models to calculate stress/strain. In-vivo analysis was performed using a critical defect model in 23 mice over an 8 week period. Bone formation was assessed using microCT and histological analysis. Finally, a computer modelling process was developed to convert patient CT images into surface models, then formatted into 3D-printable scaffolds to fill critical defects. Following EO sterilisation, there was no change in scaffold surface and persistent availability of growth factors. Scaffolds showed adequate porosity for cell migration with mechanical stiffness similar to cancellous bone. Finally, the in vivo murine model demonstrated rapid bone formation with evidence of trabecular remodelling in samples presenting growth factors compared to controls


Aims

Our objective was to conduct a systematic review and meta-analysis, to establish whether differences arise in clinical outcomes between autologous and synthetic bone grafts in the operative management of tibial plateau fractures.

Methods

A structured search of MEDLINE, EMBASE, the online archives of Bone & Joint Publishing, and CENTRAL databases from inception until 28 July 2021 was performed. Randomized, controlled, clinical trials that compared autologous and synthetic bone grafts in tibial plateau fractures were included. Preclinical studies, clinical studies in paediatric patients, pathological fractures, fracture nonunion, or chondral defects were excluded. Outcome data were assessed using the Risk of Bias 2 (ROB2) framework and synthesized in random-effect meta-analysis. The Preferred Reported Items for Systematic Review and Meta-Analyses guidance was followed throughout.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 4 | Pages 522 - 529
1 Apr 2009
Ryzewicz M Morgan SJ Linford E Thwing JI de Resende GVP Smith WR

Nonunion of the tibia associated with bone loss, previous infection, obliteration of the intramedullary canal or located in the distal metaphysis poses a challenge to the surgeon and significant morbidity to patients. We retrospectively reviewed the records of 24 patients who were treated by central bone grafting and compared them to those of 20 who were treated with a traditional posterolateral graft. Central bone grafting entails a lateral approach, anterior to the fibula and interosseous membrane which is used to create a central space filled with cancellous iliac crest autograft. Upon consolidation, a tibiofibular synostosis is formed that is strong enough for weight-bearing. This procedure has advantages over other methods of treatment for selected nonunions. Of the 24 patients with central bone grafting, 23 went on to radiographic and clinical union without further intervention. All healed within a mean of 20 weeks (10 to 48). No further bone grafts were required, and few complications were encountered. These results were comparable to those of the 20 patients who underwent posterolateral bone grafting who united at a mean of 31.3 weeks (16 to 60) but one of whom required below-knee amputation for intractable sepsis. Central bone grafting is a safe and effective treatment for difficult nonunions of the tibia


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 6 | Pages 867 - 871
1 Aug 2000
Ring D Jupiter JB Quintero J Sanders RA Marti RK

We treated 15 patients with atrophic nonunion of a diaphyseal fracture of the humerus with an associated bony defect using an autogenous cancellous bone graft and a plate to bridge the defect. There were nine men and six women with a mean age of 48 years. The mean length of the bony defect was 3 cm. At a mean follow-up of 30 months only one fracture failed to unite. This suggests that, in the presence of a well-vascularised envelope of muscle, the application of an autogenous cancellous bone graft in conjunction with a bridging plate represents a good alternative to more demanding surgical techniques


The Bone & Joint Journal
Vol. 103-B, Issue 3 | Pages 456 - 461
1 Mar 2021
Sasaki G Watanabe Y Yasui Y Nishizawa M Saka N Kawano H Miyamoto W

Aims

To clarify the effectiveness of the induced membrane technique (IMT) using beta-tricalcium phosphate (β-TCP) for reconstruction of segmental bone defects by evaluating clinical and radiological outcomes, and the effect of defect size and operated site on surgical outcomes.

Methods

A review of the medical records was conducted of consecutive 35 lower limbs (30 males and five females; median age 46 years (interquartile range (IQR) 40 to 61)) treated with IMT using β-TCP between 2014 and 2018. Lower Extremity Functional Score (LEFS) was examined preoperatively and at final follow-up to clarify patient-centered outcomes. Bone healing was assessed radiologically, and time from the second stage to bone healing was also evaluated. Patients were divided into ≥ 50 mm and < 50 mm defect groups and into femoral reconstruction, tibial reconstruction, and ankle arthrodesis groups.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 11 | Pages 1487 - 1494
1 Nov 2008
Zlowodzki M Brink O Switzer J Wingerter S Woodall J Petrisor BA Kregor PJ Bruinsma DR Bhandari M

We have studied the effect of shortening of the femoral neck and varus collapse on the functional capacity and quality of life of patients who had undergone fixation of an isolated intracapsular fracture of the hip with cancellous screws. After screening 660 patients at four university medical centres, 70 patients with a mean age of 71 years (20 to 90) met the inclusion criteria. Overall, 66% (46 of 70) of the fractures healed with > 5 mm of shortening and 39% (27 of 70) with > 5° of varus. Patients with severe shortening of the femoral neck had significantly lower short form-36 questionnaire (SF-36) physical functioning scores (no/mild (< 5 mm) vs severe shortening (> 10 mm); 74 vs 42 points, p < 0.001). A similar effect was noted with moderate shortening, suggesting a gradient effect (no/mild (< 5 mm) vs moderate shortening (5 to 10 mm); 74 vs 53 points, p = 0.011). Varus collapse correlated moderately with the occurrence of shortening (r = 0.66, p < 0.001). Shortening also resulted in a significantly lower EuroQol questionnaire (EQ5D) index scores (p = 0.05). In a regression analysis shortening of the femoral neck was the only significant variable predictive of a low SF-36 physical functioning score (p < 0.001)


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 201 - 201
1 Sep 2012
Devine D Arens D Burelli S Bloch HR Boure L
Full Access

The osteointegration of a new three-dimensional reticular titanium material, Trabecular Titanium™, was assessed using a bilateral cancellous (distal femur, proximal tibia) and cortical (tibia diaphysis) bone drill hole model in 18 sheep. TT is a novel Ti6Al4V material characterized by a high open porosity and composed of multi-planar regular hexagonal cells. Two 5.0 mm diameter, 12 mm long cylinders (TT1 & TT2) of two different porosities (TT1:650 μm, TT2:1250 μm) were tested and compared to two solid predicate 5.0 mm diameter, 12 mm long Ti cylinders (PT1 & PT2) coated with porous Ti (PT1: vacuum-plasma spray coating; PT2: inert-gas shielding arc spray coating). Each implant type was surgically implanted at 4 separate locations in each sheep (16 implants per sheep). Three timepoints of 4, 16 and 52 weeks (n=6 sheep per timepoint) were used. Bone-implant interface was analyzed ex vivo by the determination of: 1) the shear strength (SS) measured during a push out test, 2) the percentage of bone in-growth (%B) using histomorphometry, 3) the bone apposition rate using fluorochrome labelling analysis and 4) the bone-implant contact using backscattered scanning electron microscopy (SEM). An ANOVA with a Bonferroni Post hoc test were used to detect differences between tested and predicate implants. P values 0.05 were considered significant. At 4 weeks, 5 out of the 6 TT1 could be pushed out of the cortical bone (COB) samples. The remaining TT1 collapsed during testing. All TT1 could be pushed of the cancellous bone (CAB) samples. Four out of the 6 TT2 could be pushed out of CAB and of the COB samples. At 16 and 52 weeks, only one TT1 and one TT2 could be pushed out of the bone samples, the remaining implants collapsed during testing. All the PTs were successfully pushed out at all timepoints. The mean %B of PT1 and PT2 did not significantly increase over time. For both materials, the mean %B ranged between 1.7% and 4.4% at 4 weeks and between 5.7% and 6.5% at 52 weeks. The mean %B of TT1 significantly increased over time in both COB (10.2% at 4 weeks, 46.2% at 16 weeks, 50.5% at 52 weeks) and CAB (5.8%, 23.9%, 24.3%). Similarly, the mean %B of TT2 significantly increased over time in both COB (7.8%, 48.6%, 65%) and CAB (4.5%, 24.1%, 38.6%). Bone apposition rates for the TT implants remained superior to 2 μm/day for the entire duration of the study. SEM showed an intimate bone-implant contact for all implant types at all timepoints. At 16 and 52 weeks, histomorphometry revealed an extensive osteointegration of the TT specimens. Bone-implant interface strength was so high for the TT implants that they could not be pushed out of the bone samples. The results of this study would indicate that the TT implants provide a good scaffold for bone in-growth