Objectives.
Introduction: A number of surgical techniques have been described for the operative treatment of late stage osteochondritis dissecans (OCD) in the knee and ankle that have failed nonoperative management. However, no particular technique has been universally successful. We report the results of a new technique using retrograde drilling combined with the use of a novel collagen based
Aims. Demineralised bone matrix (DBM) is rarely used for the local
delivery of prophylactic antibiotics. Our aim, in this study, was
to show that a graft with a bioactive glass and DBM combination,
which is currently available for clinical use, can be loaded with
tobramycin and release levels of antibiotic greater than the minimum
inhibitory concentration for Staphylococcus aureus
without interfering with the bone healing properties of the graft,
thus protecting the graft and surrounding tissues from infection. Materials and Methods. Antibiotic was loaded into a graft and subsequently evaluated
for drug elution kinetics and the inhibition of bacterial growth.
A rat femoral condylar plug model was used to determine the effect
of the graft, loaded with antibiotic, on bone healing. Results. We found that tobramycin loaded into a graft composed of bioglass
and DBM eluted antibiotic above the minimum inhibitory concentration
for three days in vitro. It was also found that
the antibiotic loaded into the graft produced no adverse effects
on the bone healing properties of the DBM at a lower level of antibiotic. Conclusion. This antibiotic-loaded
Screw stripping in osteoporotic bone and bone of otherwise poor quality represents a common problem. Treatment alternatives, such as using a larger diameter screw or a longer plate, may add time, increase morbidity, be impractical, or simply be ineffective. Alternatively, the stripped screw can be augmented with a bone cement. A new injectable synthetic cortical
A resorbable, antibiotic-eluting
Calcium sulphate is now a proven adjunct to the replenishment of bone stock in joint replacement surgery. Alone and as a composite, it has been used successfully for many years in both dental and orthopaedic applications. OsteoSet (Wright Medical Technology), a processed, purified material, has been used as a
Cerament, a bioresorbable hydroxyapatite and calcium sulfate cement, is known to be used as a bone-graft substitute in traumatic bone defect cases. However, its use in open fractures has not previously been studied. Retrospective, single-centre review of cases between November 2016 and February 2021. Open fractures were categorised according to the Orthopaedic Trauma Society classification (OTS). Cases were assessed for union, time to union, and associated post-operative complications.Introduction
Materials and Methods
A total of 20 patients with a depressed fracture
of the lateral tibial plateau (Schatzker II or III) who would undergo open
reduction and internal fixation were randomised to have the metaphyseal
void in the bone filled with either porous titanium granules or
autograft bone. Radiographs were undertaken within one week, after
six weeks, three months, six months, and after 12 months. The primary outcome measure was recurrent depression of the joint
surface: a secondary outcome was the duration of surgery. The risk of recurrent depression of the joint surface was lower
(p <
0.001) and the operating time less (p <
0.002) when titanium
granules were used. The indication is that it is therefore beneficial to use porous
titanium granules than autograft bone to fill the void created by
reducing a depressed fracture of the lateral tibial plateau. There
is no donor site morbidity, the operating time is shorter and the
risk of recurrent depression of the articular surface is less. Cite this article:
To test the hypothesis that: CERAMENT[™]|G (C-G) would improve new bone growth and decrease infection rate after debridement as compared with 1) CERAMENT|BONE VOID FILLER (CBVF) and 2) no void filler in a rat osteomyelitis model. 72 Sprague Dawley rats were injected with 1.5 × 10∧6 CFU of S. aureus into a drill hole in the right tibia. After 3 weeks, the osteomyelitic defect was debrided, and filled with either: 1) C-G (n=32), 2) CBVF (n=20), or 3) nothing (n=20). 6 weeks after the second surgery, 20 rats from each group were sacrificed and the right tibias were harvested. A long-term group (n=12) of C-G treated rats were also sacrificed at 6 months after the second surgery. The tissues were sonicated and the colony forming units in the sonicate were quantified by serial dilutions and culture. MicroCT was used to quantify the new bone growth (BV/TV) in the debrided osteomyelitic void. Histological samples were analyzed for the presence of a neutrophil response by a blinded pathologist. (*: p<0.05) Positive cultures in:
○ 30% of animals treated with CBVF ○ 25% of animals treated with no void filler ○ 0% of animals treated with C-G (*) Neutrophil reaction in:
○ 35% of animals treated with CBVF ○ 50% of animals treated with no void filler ○ 0% of animals treated with C-G (*) The BV/TV in:
○ C-G treated rats was 24% greater than CBVF treated rats (*) ○ C-G treated rats was 94% greater than rats treated with no void filler (*) ○ CBVF treated rats was 56% greater than rats treated with no void filler (*) Animals sacrificed at 6 months which were treated with C-G did not have any evidence of infection by culture or histology. The bone mass of the implanted limb was higher than the contralateral (non-operated) side. CERAMENT|G decreased the rate of infection and increased new bone growth as compared with both CBVF and no void filler in a debrided osteomyelitic environment. Animals treated with C-G at 6 months showed no evidence of infection and retained a higher bone mass relative to the contralateral (non-operated) side. This study supports the use of CERAMENT|G as a readily available void filler which could be used in osteomyelitic environments after debridement.
We reviewed 59 bone graft substitutes marketed
by 17 companies currently available for implantation in the United Kingdom,
with the aim of assessing the peer-reviewed literature to facilitate
informed decision-making regarding their use in clinical practice.
After critical analysis of the literature, only 22 products (37%)
had any clinical data. Norian SRS (Synthes), Vitoss (Orthovita),
Cortoss (Orthovita) and Alpha-BSM (Etex) had Level I evidence. We question
the need for so many different products, especially with limited
published clinical evidence for their efficacy, and conclude that
there is a considerable need for further prospective randomised
trials to facilitate informed decision-making with regard to the
use of current and future bone graft substitutes in clinical practice. Cite this article:
Aim. There are no definitive criteria for the definition of osteomyelitis in the hand and wrist and published case series are small. It remains a relatively uncommon, but difficult to treat problem. We present a series of 30 cases from 2016 to 2021 from a tertiary referral centre. We propose that the principles of thorough surgical debridement, dead space management, skeletal stabilisation and culture driven antibiotic therapy are the key to management of osteomyelitis in the hand and wrist. In addition, we show how these basic principles can be used for both functional and aesthetic impact for the wrist and digits with illustrated cases. Methods. We conducted a retrospective chart review over a 6 year period and recorded the site of the infection, the soft tissue and bony management, whether antibiotic eluting bone filler was used, the isolated bacterial species, the number of surgical procedures undertaken to treat the infection and the success rate for clearing the infection. Results. 17/30 cases had pre-existing metalwork in-situ. There were 19 phalangeal/metacarpal infections and 11 carpal infections. 24 patients had native joint involvement. A drug eluting
Aim. To study the antimicrobial effect of a gentamicin loaded bio-composite
Introduction. When third body particles originating from bone cement or
Objective . A clinical investigation into a new
Purpose. Infections in orthopaedic surgery are costly, debilitating complications. The search for new treatments and prevention strategies has led to the use of antibiotic-filled calcium sulfate (CaS) as a
Aim. Antibiotic-loaded biomaterials are often used in dead space management after excision of infected bone. This study assessed the chronological progression of new bone formation in infected defects, filled only with an absorbable, osteoconductive
Introduction. Calcium sulfate
Calcium phosphate cements (CPC) are used as biocompatible and bioactive
Autogenous bone grafting limitations have motivated the development of Tissue-Engineered (TE) biomaterials that offer an alternative as
Gentamicin sulphate is a potent antibiotic, widely used by clinicians to treat Staphylococcus aureus bacterial complications in orthopaedic surgery and osteomyelitis. Antibiotics as administered are poorly localised and can accumulate with toxic effects. Achieving a better targeted release and controlled dosage has been an ongoing unmet microengineering challenge. In this study we evaluated the antibiotic release potential of beta tricalcium phosphate (β-TCP) micro and macrospheres to eradicate Staphylococcus aureus and maintain osteoblast biocompatibility. Gentamicin was absorbed onto and within the spheres at an average amount of 4.2 mg per sample. Human osteoblast cell studies at five days incubation showed attachment and growth on the spheres surface with no detrimental effect on the cell viability. A time delayed antibacterial efficacy test was designed with the bacteria introduced at predetermined time intervals from 0–60 minutes. We demonstrated that hydroxyapatite covered Foraminifera nano-, micro- macrospheres facilitated the slow release of the encapsulated pharmaceutical agent. Principally, this arises owing to their unique architecture of pores, struts and channels, which amplifies physiological degradation and calcium phosphate dissolution to release attached pharmaceuticals in a controlled manner. The Staphylococcus aureus growth response following exposure to the gentamicin incorporated microspheres at various time intervals showed the complete elimination of the bacteria within 30 minutes. Gentamicin release continued with no re-emergence of bacteria. β-TCP nano to macro size spheres show promise as potential