Introduction. Initial post-operative implant instability leads to impaired osseointegration, one of the most common reasons for aseptic loosening and revision surgery. In this study, we developed a novel murine model of implant instability and demonstrated the anabolic effect of immediate and delayed intermittent Parathyroid Hormone (iPTH) treatment in the setting of instability-induced osseointegration failure. Methods. 3D-printed titanium implants were inserted in an oversized drill-hole in the tibia of C57Bl/6 mice (n=54). After implantation, the mice were randomly divided in 3 treatment groups (control: PBS-vehicle; iPTH; delayed iPTH). Radiographic analysis was performed to confirm signs of implant loosening. Peri-implant tissue formation was assessed through histology. Osseointegration was assessed through µCT and biomechanical pullout testing. Results. Immediate iPTH treatment reduced radiolucencies and induced a distinct pedestal sign distal to the implant stem (white arrow Fig 1A). The PBS treated mice had fibrous tissue implant encapsulation, whereas new mineralized tissue and no fibrous tissue was observed with immediate iPTH treatment (Fig 1E). Delayed iPTH treatment was also able to exhibit significant peri-implant bone mineralization, osteoblasts, angiogenesis, and a reduction of fibrous tissue (Fig 2A-B). iPTH treatment increased the force required to pull out the implant significantly from 8.41 ± 8.15N in the PBS group to 21.49 ± 10.45N and 23.68 ± 8.99N, in the immediate and delayed iPTH treatment groups, respectively (Fig 2D). PBS vehicle resulted in a bone volume/trabecular volume (BV/TV) of 0.23 ± 0.03, while immediate and delayed iPTH treatment increased BV/TV significantly to 0.46 ± 0.07 and 0.34 ± 0.10, respectively (Fig 2E). Conclusion. Immediate iPTH treatment prevents peri-implant fibrous tissue formation and enhances peri-implant
Aims. Options for the treatment of intra-articular ligament injuries are limited, and insufficient ligament reconstruction can cause painful joint instability, loss of function, and progressive development of degenerative arthritis. This study aimed to assess the capability of a biologically enhanced matrix material for ligament reconstruction to withstand tensile forces within the joint and enhance ligament regeneration needed to regain joint function. Materials and Methods. A total of 18 New Zealand rabbits underwent bilateral anterior cruciate ligament reconstruction by autograft, FiberTape, or FiberTape-augmented autograft. Primary outcomes were biomechanical assessment (n = 17), microCT (µCT) assessment (n = 12), histological evaluation (n = 12), and quantitative polymerase chain reaction (qPCR) analysis (n = 6). Results. At eight weeks, FiberTape alone or FiberTape-augmented autograft demonstrated increased biomechanical stability compared with autograft regarding ultimate load to failure (p = 0.035), elongation (p = 0.006), and energy absorption (p = 0.022). FiberTape-grafted samples also demonstrated increased bone mineral density in the bone tunnel (p = 0.039). Histological evaluation showed integration of all grafts in the bone tunnels by new
To evaluate whether low-intensity pulsed ultrasound (LIPUS) accelerates bone healing at osteotomy sites and promotes functional recovery after open-wedge high tibial osteotomy (OWHTO). Overall, 90 patients who underwent OWHTO without bone grafting were enrolled in this nonrandomized retrospective study, and 45 patients treated with LIPUS were compared with 45 patients without LIPUS treatment in terms of bone healing and functional recovery postoperatively. Clinical evaluations, including the pain visual analogue scale (VAS) and Japanese Orthopaedic Association (JOA) score, were performed preoperatively as well as six weeks and three, six, and 12 months postoperatively. The progression rate of gap filling was evaluated using anteroposterior radiographs at six weeks and three, six, and 12 months postoperatively.Aims
Methods
This study aimed to explore the biological and clinical importance of dysregulated key genes in osteoarthritis (OA) patients at the cartilage level to find potential biomarkers and targets for diagnosing and treating OA. Six sets of gene expression profiles were obtained from the Gene Expression Omnibus database. Differential expression analysis, weighted gene coexpression network analysis (WGCNA), and multiple machine-learning algorithms were used to screen crucial genes in osteoarthritic cartilage, and genome enrichment and functional annotation analyses were used to decipher the related categories of gene function. Single-sample gene set enrichment analysis was performed to analyze immune cell infiltration. Correlation analysis was used to explore the relationship among the hub genes and immune cells, as well as markers related to articular cartilage degradation and bone mineralization.Aims
Methods
To explore the efficacy of extracorporeal shockwave therapy (ESWT) in the treatment of osteochondral defect (OCD), and its effects on the levels of transforming growth factor (TGF)-β, bone morphogenetic protein (BMP)-2, -3, -4, -5, and -7 in terms of cartilage and bone regeneration. The OCD lesion was created on the trochlear groove of left articular cartilage of femur per rat (40 rats in total). The experimental groups were Sham, OCD, and ESWT (0.25 mJ/mm2, 800 impulses, 4 Hz). The animals were euthanized at 2, 4, 8, and 12 weeks post-treatment, and histopathological analysis, micro-CT scanning, and immunohistochemical staining were performed for the specimens.Aims
Methods
Aims. It is increasingly appreciated that coordinated regulation of angiogenesis and osteogenesis is needed for
Unicompartmental and total knee arthroplasty (UKA and TKA) are successful treatments for osteoarthritis, but the solid metal implants disrupt the natural distribution of stress and strain which can lead to bone loss over time. This generates problems if the implant needs to be revised. This study investigates whether titanium lattice UKA and TKA implants can maintain natural load transfer in the proximal tibia. In a cadaveric model, UKA and TKA procedures were performed on eight fresh-frozen knee specimens, using conventional (solid) and titanium lattice tibial implants. Stress at the bone-implant interfaces were measured and compared to the native knee.Aims
Methods
Purpose. The purpose of this study was to assess radiologically the absorption of a poly L-lactide bioabsorbable interference screw used in anterior ligament reconstruction. Methods. A case series of ten sequential patients undergoing anterior ligament reconstruction with a four-strand hamstrings technique were assessed with MRI scans at one, two, four, seven and ten years postoperatively. The scans were reported by an independent radiologist, with respect to resorption of the screw and post resorption changes in the bone. Fixation of the graft in ACL surgery is varied from metal interference screw, resorbable screws made of PLLA, and staple fixation. The advantage of resorbable screws allow imaging of the knee postoperatively, and the perceive benefit of screw resorption and replacement with host bone. Results. No resorption had occurred after 4 years in any of the patients. By seven years screw absorption was complete in seven patients and progressive in three. Five patients displayed new
Introduction. Poor osseointegration of cementless implants is the leading clinical cause of implant loosening, subsidence, and replacement failure, which require costly and technically challenging revision surgery. The mechanism of osseointegration requires further elucidation. We have recently developed a novel titanium implant for the mouse tibia that maintains in vivo knee joint function and allows us to study osseointegration in an intra-articular, load-bearing environment. Vascular endothelial growth factor (VEGF) is one of the most important growth factors for regulation of vascular development and angiogenesis. It also plays critical roles in skeletal development and bone repair and regeneration. A specialized subset of vascular endothelium, CD31. hi. EMCN. hi. cells displaying high cell surface expression of CD31 and Endomucin, has been reported to promote osteoblast maturation and may be responsible for
The COVID-19 pandemic has led to unprecedented times worldwide. From lockdowns to masks now being part of our everyday routine, to the halting of elective surgeries, the virus has touched everyone and every part of our personal and professional lives. Perhaps, now more than ever, our ability to adapt, change and persevere is critical to our survival. This year's closed meeting of The Knee Society demonstrated exactly those characteristics. When it became evident that an in-person meeting would not be feasible, The Knee Society leadership, under the direction of President John Callaghan, MD and Program Chair Craig Della Valle, MD created a unique and engaging meeting held on September 10–12, 2020. Special recognition should be given to Olga Foley and Cynthia Garcia at The Knee Society for their flexibility and creativeness in putting together a world-class flawless virtual program. The Bone & Joint Journal is very pleased to partner with The Knee Society to once again publish the proceedings of the closed meeting of the Knee Society. The Knee Society is a United States based society of highly selected members who have shown leadership in education and research in knee surgery. It invites up to 15% international members; this includes some of the key opinion leaders in knee surgery from outside the USA. Each year, the top research papers from The Knee Society meeting will be published and made available to the wider orthopaedic community in The Bone & Joint Journal. The first such proceedings were published in BJJ in 2019. International dissemination should help to fulfil the mission and vision of the Knee Society of advancing the care of patients with knee disorders through leadership, education and research. The quality of dissemination that The Bone & Joint Journal provides should enhance the profile of this work and allow a larger body of surgeons, associated healthcare professionals and patients to benefit from the expertise of the members of The Knee Society. The meeting is one of the highlights of the annual academic calendar for knee surgeons. With nearly every member in attendance virtually throughout the 3 days, the top research papers from the membership were presented and discussed in a virtual format that allowed for lively interaction and discussion. There are 75 abstracts presented. More selective proceedings with full papers will be available after a robust peer review process in 2021, both online and in The Bone & Joint Journal. The meeting commenced with the first group of scientific papers focused on Periprosthetic Joint Infection. Dr Berry and colleagues from the Mayo Clinic further help to clarify the issue of serology and aspirate results to diagnose TKA PJI in the acute postoperative setting. 177 TKA's had an aspiration within 12 weeks and 22 were proven to have PJI. Their results demonstrated that acute PJI after TKA should be suspected within 6 weeks if CRP is ≥81 mg/L, synovial WBCs are ≥8500 cells/μL, and/or synovial neutrophils≥86%. Between 6– 12 weeks, concerning thresholds include a CRP ≥ 32 mg/L, synovial WBC ≥7450, and synovial neutrophils ≥ 84%. While historically the results of a DAIR procedure for PJI have been variable, Tom Fehring's study showed promise with the local delivery of vancomycin through the Intraosseous route improved early results. New member Simon Young contrasted the efficacy of the DAIR procedure when comparing early infections to late acute hematogenous PJI. DAIR failed in 63% of late hematogenous PJIs (implant age>1 year) compared to 36% of early (<1year) PJIs. Dr Masri demonstrated in a small group of patients that those with well-functioning articulating spacers can retain their spacers for over 12 months with no difference in infection from those that had a formal two stage exchange. The mental toll of PJI was demonstrated in a longitudinal study by Doug Dennis, where patient being treated with 2 stage exchange had 4x higher rates of depression compared to patient undergoing aseptic revision. The second session focused on both postoperative issues with regards to anticoagulation and manipulation. Steven Haas demonstrated high complication rates with utilization of anticoagulation for treatment of postoperative pulmonary embolism with modern therapeutic anticoagulation (warfarin, enoxaparin, Xa inhibitors) with the Xa inhibitors demonstrating lower complication rates. Two papers focused on the topic of manipulation. Mark Pagnano presented data on timing of manipulation under anesthesia up to even past 12 months. While gains were modest, a subset of patients did achieve substantial gains in ROM > 20degrees even after 3 months post op. Dr Westrich's study demonstrated no difference in MUA outcomes with either IV sedation or neuraxial anesthesia although the length of stay was shorter in the IV sedation group. Several studies in Session II focused on kinematics and femoral component position. Dr Li's in vivo kinematic study during weightbearing flexion and gait demonstrated that several knees rotated with a lateral pivot motion and not all knees can be described with a single motion character. Dr Mayman and his group utilized a computational knee model to demonstrate that additional distal femoral resection results in increasing levels of mid -flexion instability and cautioned against the use of additional bony resection as the first line for flexion contractures. Using computer navigation, Dr Huddleston's study nicely outlined the variability in femoral component rotation to achieve a rectangular flexion gap utilizing a gap balanced method. The third session opened the meeting on Friday morning. The focus was on unicompartmental knee arthroplasty and the increasing utilization of robotic assisted total knee arthroplasty. David Murray showed using registry data that for patient with higher comorbidities (ASA >3), UKA was safer and more cost effective than TKA while Dr Della Valle's group demonstrated overall lower average healthcare costs in UKA patients compared to TKA in the first 10 years after surgery. Dr Geller assessed UKA survivorship among 3 international registries. While survivorship varied by nation and designs, certain designs consistently had better overall performance. Dr Nunley and his group showed robotic navigation UKA significantly reduced outliers in alignment and overhang compared to manual UKA. Dr Catani's data demonstrated that full thickness cartilage loss should still be considered a requirement for UKA success even with robotic assistance. Despite a high dislocation rate of 4%, Mr Dodd demonstrated high survivorship for lateral UKA despite historical contraindications. The growing evidence for robotics TKA was demonstrated in two studies. Professor Haddad showed less soft tissue injury, reduced bone trauma and improved accuracy or rTKA compared to manual TKA while Dr Gustke single surgeon study showed his rTKA had improved forgotten joint scores and less ligament releasing required for balancing. Despite these finding, Dr Lee's study demonstrated that a robotic TKA could not guarantee excellent pain relief and other factors such a patient expectations and psychological factors play a role. Our fourth session was devoted to machine learning and smart tools and modeling. Dr Meneghini used machine learning algorithms to identify optimal alignment outcomes that correlated with patient outcomes. Several parameters such as native tibial slope, femoral sagittal position and coronal limb alignment correlated with outcomes. Along the same lines, Bozic and coauthors demonstrated that using AI algorithms incorporated with PROM's improved levels of shared decision making and patient satisfaction. Dr Lombardi demonstrated that a mobile patient engagement platform that provided smart phone-based exercise and education was comparable to traditional methods. Dr Mahfouz demonstrated the accuracy of using ultrasound to produce 3D models of the bone compared to conventional CT based strategies and Dr Mahoney showed the valued of a preop 3D model in reproducing more normal knee kinematics. The last two talks of the session focused on some of the positives of the COVID-19 pandemic, namely the embracing of telemedicine by patients and surgeons as demonstrated by Dr Slover and the increasing and far reaching educational opportunities made available to residents and fellows during the pandemic. Session five focused on risk stratification and optimization prior to TKA. Dr O'Connor demonstrated that that the implementation of an optimization program preoperatively reduced length of stay and ED visits, and Charles Nelson's study showed that risk stratification tool can lower complication rates in obese patients undergoing TKA comparable to those that are nonobese. Dr Markel's study demonstrated that those who have preoperative depression and anxiety are at higher risk of complications and readmissions after surgery and these issues should be addressed preoperatively. Interestingly, a study by Dr Callaghan demonstrated that care improvement pathways have not lowered the gap in complications for morbidly obese patients undergoing TKA, Dr Barsoum argued that the overall complication rates were low and this patient cohort had significant gains in PROMS after TKA that would not be experienced if arbitrary cutoff for limited surgery were established. The final session on Friday, Session six, had several well done and interesting studies. There continues to be mounting evidence that liposomal bupivacaine has little effect on managing post-operative pain to warrant its increased use. Bill Macaulay and colleagues showed no change in pain scores, opioid consumption and functional scores when liposomal bupivacaine was discontinued at a large academic medical center. Dr Bugbee importantly demonstrated that a supervised ambulation program reduced falls in the early postoperative period. Several paper on healthcare economics were presented. Rich Iorio showed that stratifying complexity of total joint cases between hospitals with a system can be efficient and cost savings while Dr Jiranek demonstrated in his study that complex TKAs can be identified preoperatively and are associated with prolonged operative time and cost of care and consideration should be given in future reimbursement models to a complexity modifier. Dr Springer, in their evaluation of Medicare bundled payment models, demonstrated that providers and hospitals in historical bundled models that became efficient were penalized in the new model, forcing many groups to drop out and return to a fee for service model. Ron Delanois important work showed that social determinants can have a major negative impact on outcomes following TKA. Our final day on Saturday opened with Session seven, and several interesting paper on metal ions/debris in TKA. Dr Whitesides simulator study showed the absence of scratches and material loss in a ceramic TKA compared with Co-Cr TKA and suggested an advantage to this material in patients with metal sensitivity. Conversely, in a histological study of failed TKA, perivascular lymphocytic infiltration was not associated with worse clinical outcomes or differences in revision in a series of 617 aseptic revisions, 19% of which had PVLI found on histology. The Mayo group and Dr Trousdale however, noted that serum metal ion levels can be helpful in identifying implant failure in a group of revision TKAs, especially those with metallic junctions. Dr Dalury demonstrated nicely that use of maximally conforming inserts did not have a negative effect on implant loosening in a series of 76 revision TKA's at an average follow up of 7 years, while Kevin Garvin and his group showed no difference in end of stem pain between cemented and cementless stems in revision TKA. The final two studies in the session by Bolognesi and Peters respectively showed that metaphyseal cones continue to demonstrate excelled survivorship in rTKA setting despite extensive bone loss. Session eight was highlighted by a large series of revision reported by new member Dr Schwarzkopf, who showed that revision TKA done by high volume surgeons demonstrated better outcomes and lower revision rates compared to surgeon who did less than 18 rTKA's per year. Dr Maniar importantly showed that preoperatively, patients with high activity level and low pain and indicated by a high preop forgotten joint score did poorly following TKA while David Ayers nicely demonstrated that KOOS scores that assess specific postoperative outcomes can predict patient dissatisfaction after TKA. The final paper in this session by Max Courtney showed that the majority of surgical cancellations are due to medical issues, yet a minority of these undergo any intervention specifically for that condition, but they resulted in a delay of 5 months. The first two studies of Session nine focused on polyethylene thickness. Dr Backstein demonstrated no difference in KSS scores, change in ROM and aseptic revision rates based on polyethylene thickness in a series of 195 TKA's. An interesting lab study by Dr Tim Wright showed a surprising consistency in liner thickness choice among varying levels of surgeon experience that did not correlate with applied forces or gap stability estimates. Two studies looked specifically at the issue of tibial loosening and implant design. Nam and colleagues were not able to demonstrate concerning findings for increasing tibial loosening in a tibial baseplate with a shortened tibial keel at short term follow up, while Lachiewicz demonstrated a 19% revision or revision pending rate in 223 cemented fixed bearing ATTUNE TKA at a mean of 30 months. Our final session of the meeting, began with encouraging news, that despite only currently capturing about 40% of TJA's done in the US, the American Joint Replacement Registry data is representative of data in other representative US databases. An interesting study presented by Robert Barrack looked at bone remodeling in the proximal tibia after cemented and cementless TKA of two different designs. No significant difference was noted among the groups with the exception of the cemented thicker cobalt chrome tray which demonstrated significantly more bone mineral density loss. Along the same lines, a study out of Dr Bostrom's lab demonstrated treatment of a murine tibial model with iPTH prevents fibrous tissue formation and enhances
To compare the effect of femoral bone tunnel configuration on tendon-bone healing in an anterior cruciate ligament (ACL) reconstruction animal model. Anterior cruciate ligament reconstruction using the plantaris tendon as graft material was performed on both knees of 24 rabbits (48 knees) to mimic ACL reconstruction by two different suspensory fixation devices for graft fixation. For the adjustable fixation device model (Socket group; group S), a 5 mm deep socket was created in the lateral femoral condyle (LFC) of the right knee. For the fixed-loop model (Tunnel group; group T), a femoral tunnel penetrating the LFC was created in the left knee. Animals were sacrificed at four and eight weeks after surgery for histological evaluation and biomechanical testing.Objectives
Methods
Between 15% and 20% of patients remain dissatisfied following total knee arthroplasty (TKA). The SAIPH knee system (MatOrtho, Surrey, United Kingdom) is a medial ball and socket TKA that has been designed to replicate native knee kinematics in order to maximize the range of movement, stability, and function. This system is being progressively introduced in a stepwise fashion, with this study reporting the mid-term clinical and radiological outcomes. A retrospective review was undertaken of the first 100 consecutive patients with five-year follow-up following SAIPH TKA performed by the senior authors. The data that were collected included the demographics of the patients, clinical findings, the rate of intraoperative ligamentous release, patient-reported outcome measures (PROMS), radiological assessment, complications, and all-cause revision. Revision data were cross-checked with a national registry.Aims
Patients and Methods
This animal study compares different methods
of performing an osteotomy, including using an Erbium-doped Yttrium
Aluminum Garnet laser, histologically, radiologically and biomechanically.
A total of 24 New Zealand rabbits were divided into four groups
(Group I: multihole-drilling; Group II: Gigli saw; Group III: electrical
saw blade and Group IV: laser). A proximal transverse diaphyseal
osteotomy was performed on the right tibias of the rabbits after the
application of a circular external fixator. The rabbits were killed
six weeks after the procedure, the operated tibias were resected
and radiographs taken. The specimens were tested biomechanically using three-point bending
forces, and four tibias from each group were examined histologically.
Outcome parameters were the biomechanical stability of the tibias
as assessed by the failure to load and radiographic and histological
examination of the osteotomy site. The osteotomies healed in all specimens both radiographically
and histologically. The differences in the mean radiographic (p
= 0.568) and histological (p = 0.71) scores, and in the mean failure
loads (p = 0.180) were not statistically significant between the
groups. Different methods of performing an osteotomy give similar quality
of union. The laser osteotomy, which is not widely used in orthopaedics
is an alternative to the current methods. Cite this article:
Our aim was to examine the clinical and radiographic outcomes
in 257 consecutive Oxford unicompartmental knee arthroplasties (OUKAs)
(238 patients), five years post-operatively. A retrospective evaluation was undertaken of patients treated
between April 2008 and October 2010 in a regional centre by two
non-designing surgeons with no previous experience of UKAs. The
Oxford Knee Scores (OKSs) were recorded and fluoroscopically aligned
radiographs were assessed post-operatively at one and five years.Aims
Patients and Methods
We investigated whether strontium-enriched calcium
phosphate cement (Sr-CPC)-treated soft-tissue tendon graft results
in accelerated healing within the bone tunnel in reconstruction
of the anterior cruciate ligament (ACL). A total of 30 single-bundle
ACL reconstructions using tendo Achillis allograft were performed
in 15 rabbits. The graft on the tested limb was treated with Sr-CPC,
whereas that on the contralateral limb was untreated and served
as a control. At timepoints three, six, nine, 12 and 24 weeks after
surgery, three animals were killed for histological examination.
At six weeks, the graft–bone interface in the control group was
filled in with fibrovascular tissue. However, the gap in the Sr-CPC
group had already been completely filled in with new bone, and there
was evidence of the early formation of Sharpey fibres. At 24 weeks,
remodelling into a normal ACL–bone-like insertion was found in the
Sr-CPC group. Coating of Sr-CPC on soft tissue tendon allograft
leads to accelerated graft healing within the bone tunnel in a rabbit
model of ACL reconstruction using Achilles tendon allograft. Cite this article:
As the number of younger and more active patients
treated with total knee arthroplasty (TKA) continues to increase,
consideration of better fixation as a means of improving implant
longevity is required. Cemented TKA remains the reference standard
with the largest body of evidence and the longest follow-up to support
its use. However, cementless TKA, may offer the opportunity of a
more bone-sparing procedure with long lasting biological fixation
to the bone. We undertook a review of the literature examining advances
of cementless TKA and the reported results. Cite this article:
The purpose of this study was to compare clinical
outcomes of total knee arthroplasty (TKA) after manipulation under
anaesthesia (MUA) for post-operative stiffness with a matched cohort
of TKA patients who did not requre MUA. In total 72 patients (mean age 59.8 years, 42 to 83) who underwent
MUA following TKA were identified from our prospective database
and compared with a matched cohort of patients who had undergone
TKA without subsequent MUA. Patients were evaluated for range of
movement (ROM) and clinical outcome scores (Western Ontario and
McMaster Universities Arthritis Index, Short-Form Health Survey,
and Knee Society Clinical Rating System) at a mean follow-up of
36.4 months (12 to 120). MUA took place at a mean of nine weeks
(5 to 18) after TKA. In patients who required MUA, mean flexion
deformity improved from 10° (0° to 25°) to 4.4° (0° to 15°) (p <
0.001),
and mean range of flexion improved from 79.8° (65° to 95°) to 116°
(80° to 130°) (p <
0.001). There were no statistically significant
differences in ROM or functional outcome scores at three months,
one year, or two years between those who required MUA and those
who did not. There were no complications associated with manipulation At most recent follow-up, patients requiring MUA achieved equivalent
ROM and clinical outcome scores when compared with a matched control
group. While other studies have focused on ROM after manipulation,
the current study adds to current literature by supplementing this
with functional outcome scores. Cite this article:
Although the vast majority of patients that undergo
total knee replacement have satisfactory outcomes with a generally
low complication rate, occasionally a patient will be encountered
that has had multiple failed surgeries, and now reaches a crossroad
as to whether limb salvage will be acceptable or not. Cite this article:
The relationship between post-operative bone
density and subsequent failure of total knee replacement (TKR) is
not known. This retrospective study aimed to determine the relationship
between bone density and failure, both overall and according to
failure mechanism. All 54 aseptic failures occurring in 50 patients
from 7760 consecutive primary cemented TKRs between 1983 and 2004
were matched with non-failing TKRs, and 47 failures in 44 patients
involved tibial failures with the matching characteristics of age
(65.1 for failed and 69.8 for non-failed), gender (70.2% female), diagnosis
(93.6% OA), date of operation, bilaterality, pre-operative alignment
(0.4 and 0.3 respectively), and body mass index (30.2 and 30.0 respectively).
In each case, the density of bone beneath the tibial component was assessed
at each follow-up interval using standardised, calibrated radiographs.
Failing knees were compared with controls both overall and, as a
subgroup analysis, by failure mechanism. Knees were compared with
controls using univariable linear regression. Significant and continuous elevation in tibial density was found
in knees that eventually failed by medial collapse (p <
0.001)
and progressive radiolucency (p <
0.001) compared with controls,
particularly in the medial region of the tibia. Knees failing due
to ligamentous instability demonstrated an initial decline in density
(p = 0.0152) followed by a non-decreasing density over time (p =
0.034 for equivalence). Non-failing knees reported a decline in
density similar to that reported previously using dual-energy x-ray
absorptiometry (DEXA). Differences between failing and non-failing
knees were observable as early as two months following surgery.
This tool may be used to identify patients at risk of failure following
TKR, but more validation work is needed. Cite this article:
We compared peri-prosthetic bone mineral density between identical cemented and cementless LCS rotating platform total knee arthroplasties. Two matched cohorts had dual energy x-ray absorptiometry scans two years post-operatively using a modified validated densitometric analysis protocol, to assess peri-prosthetic bone mineral density. The knee that was not operated on was also scanned to enable the calculation of a relative bone mineral density difference. Oxford Knee and American Knee Society scores were comparable in the two cohorts. Statistical analysis revealed no significant difference in absolute, or relative peri-prosthetic bone mineral density with respect to the method of fixation. However, the femoral peri-prosthetic bone mineral density and relative bone mineral density difference were significantly decreased, irrespective of the method of fixation, particularly in the anterior distal portion of the femur, with a mean reduction in relative bone mineral density difference of 27%. There was no difference in clinical outcome between the cemented and cementless LCS total knee arthroplasty. However, both produce stress-shielding around the femoral implants. This leads us to question the use of more expensive cementless total knee components.