Advertisement for orthosearch.org.uk
Results 1 - 17 of 17
Results per page:
Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 132 - 132
1 Sep 2012
Milosev I Kovac S Trebse R Levasic V Topolovec M Pisot V
Full Access

Introduction. Alternative bearings – metal-on-metal and ceramic-on-ceramic bearings have been introduced in the last decade with the aim to diminish wear and, subsequently, aseptic loosening and osteolysis. These bearings were aimed for younger, more active patients. Clinical results which would compare the performance of various alternative and traditional bearings are scarce. Methods. Between January 2000 and December 2002, we performed 487 total hip replacements in 474 patients using three types of bearings: metal-on-metal (MOM), metal-on-polyethylene (MOP), and ceramic-on-ceramic (COC). All patients received the same type of acetabular cup (Bicon-Plus, Plus Orthopedics) and same type of femoral component (SL-Plus, Plus Orthopedics). We used the hospital computer database for the evaluation of patient data and data on revision operations. Results. At a mean follow-up of 8.5 years (range, 6.8 to 9.9 years), eighteen hips were revised. Seventeen revisions were aseptic, and one was septic. The percentage of revision in the whole group was 3.7%. The percentage of revisions for individual groups of bearings varied and ranged from 1.5% in the MOP group, 4.1% in the COC group to 8.7% in the MOM group. Reasons for revisions were analyzed in details. We noticed that the percentage of aseptic loosening differed among the groups, with the MOM group having the highest percentage of revisions due to aseptic loosening. Conclusions. The results obtained for this large series of THRs with the same type of acetabular and femoral components, and differing only in the type of bearing, indicate that the combination of material of acetabular cup and femoral head affect the performance of the hip prosthesis


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 262 - 262
1 Sep 2012
Buchanan J Fletcher R Linsley P
Full Access

Aims. Will Hydroxyapatite hip (HA) arthroplasty associated with ceramic bearings produce uncomplicated function in younger, active patients’ The incidence of aseptic loosening, dislocation and broken implants has been particularly investigated. Debris disease from plastic debris contributes to aseptic loosening. Hard-Hard bearings should obviate this problem. Metal-metal will release ions which might be deleterious. Experience with metal-metal resurfacing has high lighted problems including pseudo-tumours. Ceramic bearings may fracture but otherwise appear free of complications. Methods. This is a study extending over 19 years of 626 HA hip arthroplasties with ceramic bearings. Annual review using Harris Hip Score to assess pain and function and X-rays to check osseointegration has been performed. Alumina ceramic was inserted in 467 hips. The newer Zirconia Toughened Alumina (ZTA) has been inserted in 169 hips. There are 118 hips still under review at 10 or more years. Results. Aseptic loosening is unusual (one stem, two acetabulae (3 of 1252 components, 0.24%) Failure from mal-orientation with repeated dislocation occurred in six hips (0.96%). Three alumina heads (0.48%) and two alumina liners (0.32%) broke. There has been no failure of ZTA ceramic. No patients have thigh pain. Osteolysis and debris disease have not arisen. Harris Hip Scores show 91.2% scoring over 90 or 100. Lower scores mostly relate to other joint and medical problems. Conclusions. Assessments confirm that patients remain well. Aseptic loosening of HA hips is rare at 0.24%. Failure from broken alumina components is unusual. Alumina has now been superseded by ZTA for implantation. Ceramic on ceramic is a reliable selection for bearing surfaces in patients of any age and either sex


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 323 - 323
1 Sep 2012
Li C Hussain A Joseph P Kamali A
Full Access

INTRODUCTION. One of the recent advances in the hard-on-hard hip arthroplasty is the development of a new material of diffusion hardened oxidised zirconium (DHOxZr). The DHOxZr material consists of a ceramic layer on the top surface which is supported by a thick oxygen diffusion hardened (DH) zone underneath. With the desired properties of metal substrate, ceramic surface and a gradient structure of the oxygen diffusion zone, the DHOxZr-on-DHOxZr bearing combination is expected to produce low wear and minimal metal ions. This can possibly address the concerns associated with metal hypersensitivity associated with metal on metal bearings and fracture risk associated with ceramics. The aim of this study was to evaluate the wear of DHOxZr-on-DHOxZr as a possible hard on hard bearing combination in hips. METHODS. Three pairs of 50 mm DHOxZr prototype hip joint devices, each consisting of a DHOxZr modular head and a DHOxZr liner were wear tested in a ProSim hip joint simulator under standard testing conditions used by the Implant Development Centre (IDC), Smith & Nephew, Leamington Spa for 5 million cycles (Mc). The flexion/extension was 30° and 15°. The internal/external rotation was ± 10°. The force was Paul-type stance phase loading, with a maximum load of 3 kN and a standard ISO swing phase load of 0.3 kN. The test frequency was 1 Hz. Gravimetric analysis was carried out at 0, 0.5, 1, 2, 3, 4 & 5 million cycles. The lubricant was new born calf serum with 2 g/l sodium azide concentration diluted with de-ionised water to achieve average protein concentration of 20 g/l. Lubricant was changed every 0.25Mc during the first million cycles of the test and at every 0.33 Mc from 1 to 5Mc. RESULTS. A biphasic wear pattern was observed for the DHOxZr on DHOxZr devices during the test, with a running in phase from 0–1 Mc and a steady state phase from 1–5 Mc. At a confidence level of 95%, the mean wear rate was 0.21 ±0.06 mm3/Mc during the running-in stage, and the wear rate was reduced to 0.01 ±0.03 mm3/Mc during the steady state for the device tested. The wear volume loss of the DHOxZr on DHOxZr devices was significantly lower than that generated by CoCrMo metal on metal (MoM) devices (p < 0.05) under identical simulator test conditions


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 223 - 223
1 Sep 2012
Herrera L Loving L Essner A Nevelos J
Full Access

Osteolysis induced by UHMWPE debris has historically been one of the major causes of long term failure of TJR. An increase in concentration of polyethylene particles in the peri-prostheic tissue has been linked to an increased incidence of osteolysis. The dual mobility hip bearing concept mates a femoral head into a polyethylene liner which has an unconstrained articulation into a metal shell. The wear mechanism of the dual mobility hip bearing is distinct from a constrained single articulation design, which may result in a difference in wear debris particles. The aim of this study is to evaluate wear debris generated from a dual mobility hip and compare it to a conventional single articulation design when both are manufactured from sequentially crosslinked and annealed polyethylene. The dual mobility hip (Restoration ADM) incorporated a 28mm CoCr femoral head into a polyethylene liner that articulates against a metal shell (48mm ID). The conventional hip (Trident®) mated a 28mm CoCr femoral head against a polyethylene liner. The polyethylene for all liners was sequentially crosslinked and annealed (X3). A hip joint simulator was used for testing at a rate of 1 Hz with cyclic Paul curve physiologic loading. A serum sample from each testing group was collected. Serum samples were protein digested following the published process by Scott et al. The digested serum was then filtered through a series of polycarbonate filter papers of decreasing size and sputter coated with gold for analysis using SEM. Image fields were randomized and wear debris was compared in terms of its length, width, aspect ration, and equivalent circular diameter (ECD). A total of 149 conventional hip particles and 114 dual mobility hip particles were imaged. Results show a majority of particles are of spherical nature and images do not indicate the presence of fibrillar or larger elongated polyethylene debris. Particle length between designs is not statistically different, while all other comparisons show statistical significance (p<0.05). It is hypothesized that the dual mobility hip system reduces the total amount of cross-shear motion on any one articulation, which aids in the reduction in wear. This design feature may be responsible for the slight difference in morphology of dual mobility wear debris when compared to the constrained hip design. The length of the particles was similar, simply indicating a different shape rather than a marked reduction in overall size. The debris generated is this study was from highly crosslinked polyethylene in two different designs, which produced a very significant decrease in quantity of particles when compared to the quantity of debris from conventional polyethylene. The wear debris was of similar length in both designs and so we do not expect any difference in biological response to debris from either device. The dual mobility design has also shown no effect of cup abduction angle on wear demonstrating forgiveness to implant positioning. This advantage, combined with the low wear rate and similar length wear particles, should lead to good clinical performance of dual mobility cups with sequentially irradiated and annealed polyethylene.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 200 - 200
1 Sep 2012
Williams S Isaac G Fisher J
Full Access

INTRODUCTION. Ceramic-on-metal hip replacements (COM, where the head is a Biolox Delta ceramic and liner is Co Cr alloy), have demonstrated reduced wear under standard conditions in vitro compared to metal-on-metal (MOM) [1]. Early clinical results are also encouraging [2]. Recently concerns have been raised regarding the poor clinical performance of MOM hip resurfacings [3], particularly when cups are steeply inclined. Laboratory hip simulator testing has been used to replicate edge loading, also demonstrating elevated wear [4]. Therefore, a range of conditions to replicate sub-optimal use clinically to better predict in vivo performance should be used. The aim of this study was to compare the wear rates of MOM and COM under adverse edge loading conditions in an in vitro hip simulator test. METHODS. Ceramic-on-metal (n=3) and metal-on-metal (n=3) 36mm hip prostheses (supplied by DePuy International Ltd, UK) were tested in the Leeds Physiological Anatomical Hip Joint Simulator. Liners were mounted to provide a clinical angle of 45o, and stems positioned anatomically. A simplified gait cycle and microseparation was applied as previously described [5] for two million cycles in 25% new born calf serum. Gravimetric analysis was completed every million cycles and wear volumes calculated. RESULTS. The overall mean volumetric wear rate of COM bearings was 0.36 ± 0.55mm3 per million cycles, this was significantly less than the MOM bearing wear (1.32 ± 0.91mm3 per million cycles). For both COM and MOM bearings wear under these edge loading conditions was significantly greater if compared to previously reported wear under standard conditions [1]. DISCUSSION. The reduced wear of COM has been attributed to the differential hardness decreasing adhesive wear and reduced corrosive wear [6]. Wear under the harsh edge-loading conditions in this study is also reported to be significantly less in COM bearings compared to MOM. In MOM bearings in edge contact conditions, the wear zone becomes starved of lubrication, this elevates wear and increases damage at the edge of the cup. In COM bearings the harder head does not become damaged when there is lubricant starvation and hence wear does not accelerate in the same way. In conclusion, COM bearings show reduced wear compared to MOM bearings under standard and adverse conditions and there is some early evidence to support this finding clinically. ACKNOWLEDGEMENTS. Supported by DePuy International Ltd. SW is supported by a Royal Academy of Engineering/EPSRC (UK) fellowship


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 169 - 169
1 Sep 2012
Repantis T Aroukatos P Bravou V Repanti M Korovessis P
Full Access

Background. An increased incidence of periprosthetic osteolysis, resulting in loss of biologic fixation, has been recently reported in contemporary THAs with low-carbide metal-on-metal compared to metal-on-polyethylene couple bearings. A hypersensitivity reaction due to Co and Cr debris is reported as a potential cause for failure of THAs with high-carbide bearings, but there are no evidence-based data for this reaction in low-carbide metal-on-metal bearings. Questions/purposes. We investigated whether there were differences in immunologic hypersensitivity reactions in retrievals from revised THAs with COP versus MOM bearing couples. Patients and Methods. We compared newly formed capsule and periprosthetic interface membranes retrieved from revision surgery due to aseptic failure in 20 patients with low-carbide bearings and 13 patients with ceramic-on-polyethylene bearings. For control tissue we obtained samples from the hip capsule during the primary THA implantation in 13 patients with low-carbide bearings and seven with ceramic-on-polyethylene. We examined the tissues with conventional histologic and immunohistochemical methods. Results. Compared to the controls and the tissue from patients with ceramic-on-polyethylene bearings, the tissues from patients with low-carbide metal-on-metal bearings were associated with (1) extensive necrosis and fibrin exudation in the newly formed hip capsule and (2) diffuse and perivascular lymphocytic infiltration of a higher degree than in the ceramic-on-polyethylene hips in conventional histologic examination and (3) more T than B cells. Conclusions. The conventional histologic and immunohistochemical findings in tissues retrieved from failed THAs with low-carbide metal-on-metal bearings are consistent with a link between hypersensitivity and osteolysis with low-carbide bearing couple THA


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 209 - 209
1 Sep 2012
Kluess D Kluess D Begerow I Goebel P Mittelmeier W Bader R
Full Access

Introduction. Due to the commercial launch of newly developed ceramic-on-metal (COM) bearings, we compared the deformation and stresses in the liner with ceramic-on-ceramic (COC), metal-on-metal (MOM) as well as ceramic-on-polyethylene (COP) bearings using a finite-element (FE)-model, analyzing a variety of head size and implant position. Liner deformation in terms of change in inner diameter as well as peak stresses were evaluated. Methods. The FE-model consisting of a commercial THR, the proximal femur and a section of the hemipelvis was created based on our previously published approach. Static load and muscle forces were applied according to the maximum load during gait. Polyethylene was modelled using a nonlinear definition with isotropic hardening, cobalt-chromium was modelled elastic-plastic and ceramic was modelled linear-elastic. Validity of the model was checked using an experimental setup with artificial bone and strain gauges located at the rim of the liner. Implant material (COM vs. COC vs. MOM vs. COP), head size (28 mm vs. 36 mm) and cup position (45° inclination/15° anteversion vs. 60° incl./0° antev.) were varied. Results. The experimental validation showed high correlation between strain measurements and FE-results. Liner deformation was evaluated by change in diameter at different levels. Change in head size had a high influence on cup deformation in COM, COC and MOM bearings, most possibly due to decreased liner thickness using bigger heads. Differences in MOM, COC and COM liner deformation were only in sub-micrometer range and not further evaluated. Evaluation of von Mises stress and minimum principal stress showed high differences between the bearing couples, implant positions and head sizes. COM liner stress was less sensitive to the steep cup position, but principal stress amounts were about ten times higher than in polyethylene liners. Thereby, MOM liners developed about 13 % less peak stress than COM. COC liners showed 11 % to 16 % higher stresses than COM. In accordance with published results, bigger head size correlated with lower principal stresses in the liner. Also, bigger heads were less sensitive to steep cup positions. Discussion. Deformation of the liner in total hip replacement has an important influence on lubrication, wear and clinical long-term success. The deformation occurring during intraoperative impaction and press-fit of the metal shell was not included in this study, hence the results are only valid considering the late postoperative phase when the implant is fully integrated in the bone. The FE-analysis showed no significant difference in liner deformation between COM, COC and MOM bearings. However, principal stresses were slightly higher in COM under the same conditions, but lower than COC


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 107 - 107
1 Sep 2012
Hadley M Hadfield F Hardaker C Isaac G Fisher J Wye J Barnett J
Full Access

Introduction. Hip wear simulation is a widely used technique for the pre-clinical evaluation of new bearing designs. However, wear rates seen in vitro can often be significantly different to those seen clinically. This can be attributed to the difference between the optimal conditions in a simulator and wide ranging conditions in real patients. This study aimed to develop more clinically relevant simulator tests, looking specifically at the effects of cup inclination angle (in vivo) and stop-dwell-start (SDS) protocols on a clinically available product. Method. Five tests using a Paul type walking cycle (ISO 14242) were carried out on two ProSim hip simulators: . 28mm MoM, standard walking, cup inclination 45°, (n = 5). 36mm MoM, standard walking, cup 45°, (n = 4). 36mm MOM, SDS: 10 walking cycles and pause of 5s with stance load of 1250N cup 45°, (n = 5). 36mm MOM, SDS: 10 walking cycles and pause of 30s with stance load of 1250N, (n = 5) cup 45°. 36mm MOM, standard walking, cup 55°(n = 5), and 65°(n = 5). All samples had matched clearances, measured using a CMM (Prismo Navigator, Zeiss, Germany). Wear was measured gravimetrically (Sartorius ME235S: 0.01mg). Results and Discussion. Metal-on-metal hip bearings are known to exhibit a bi-phasic wear pattern in-vitro (1), with the majority of wear occurring over the first 1–1.5mc, followed by lower steady state wear as the components conform to each other. Therefore bedding in wear over the first 1 million cycles was compared for each of the sample groups in this study. Bedding in wear for 36mm bearings under standard angle (45 inclination) and walking conditions was 0.16±0.15mm3/mc, while for 28mm bearings, wear was 2.67±2.06mm3/mc. Positioning the acetabular cup at an increased angle led to increased wear. At 55bedding in wear was .25±0.29mm3/mc, while at 65wear was 0.65±0.32mm3/mc. When SDS conditions were applied, no significant increase in wear was observed under either the 5s or 30s pause conditions, with bedding in wear of 0.19±0.31mm3/mc and 0.14±0.13mm3/mc respectively. Conclusion. This study illustrates the robust performance of the 36mm MoM bearing under extreme test conditions when compared with 28mm MoM. No effect was observed with the application of stop-dwell-start conditions, and only a small increase in wear was observed when the cup was inclined to a greater angle. Despite the application of extreme test conditions, the 36mm MoM still demonstrates lower wear than 28mm under all conditions. In all but the 65 inclination conditions, this difference is statistically significant. This study replicates some of the more frequently observed extreme conditions measured in real patients with THRs (2,3). Even under these more aggressive scenarios, wear of the 36mm bearing is still relatively low when compared with a commercially available 28mm THR


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_33 | Pages 6 - 6
1 Sep 2013
Robinson P Anthony I Kumar S Jones B Stark A Ingram R
Full Access

This study assesses the incidence of noise in ceramic on ceramic (COC) bearings compared to metal on polyethylene (MOP) bearings. Noise after MOP implants has rarely been studied and they never been linked to squeaking. We have developed a noise characterising hip questionnaire and sent it along with the Oxford Hip Score (OHS) to 1000 patients; 509 respondents, 282 COC and 227 MOP; median age 63.7 (range 45–92), median follow up 2.9 years (range 6–156 months). 47 (17%) of the COC patients reported noise compared to 19 (8%) of the MOP patients (P=0.048). 9 COC and 4 MOP patients reported their hip noise as squeaking. We found the incidence of squeaking in the COC hips to be 3.2% compared to 1.8% in the MOP hips. Overall, 27% patients with noise reported avoiding recreational activities because of it and patient's with noisy hips scored on average 4 points less in the OHS (COC: P=0.04 and MOP: P =0.007). This is the first study to report squeaking from MOP hip replacements. We therefore believe the squeaking hip phenomenon is not exclusive to hard bearings. Surprisingly, only a small proportion of patients described nose from their as a ‘squeak’. Noisy hip implants may have social implications, and patients should be aware of this. We have shown a relationship between noise and a lower OHS. However, longer follow-up and further study is needed to link noise to a poorly functioning implant


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11 | Pages 1557 - 1566
1 Nov 2012
Jameson SS Kyle J Baker PN Mason J Deehan DJ McMurtry IA Reed MR

United Kingdom National Institute for Health and Clinical Excellence guidelines recommend the use of total hip replacement (THR) for displaced intracapsular fractures of the femoral neck in cognitively intact patients, who were independently mobile prior to the injury. This study aimed to analyse the risk factors associated with revision of the implant and mortality following THR, and to quantify risk. National Joint Registry data recording a THR performed for acute fracture of the femoral neck between 2003 and 2010 were analysed. Cox proportional hazards models were used to investigate the extent to which risk of revision was related to specific covariates. Multivariable logistic regression was used to analyse factors affecting peri-operative mortality (< 90 days). A total of 4323 procedures were studied. There were 80 patients who had undergone revision surgery at the time of censoring (five-year revision rate 3.25%, 95% confidence interval 2.44 to 4.07) and 137 patients (3.2%) patients died within 90 days. After adjusting for patient and surgeon characteristics, an increased risk of revision was associated with the use of cementless prostheses compared with cemented (hazard ratio (HR) 1.33, p = 0.021). Revision was independent of bearing surface and head size. The risk of mortality within 90 days was significantly increased with higher American Society of Anesthesiologists (ASA) grade (grade 3: odds ratio (OR) 4.04, p < 0.001; grade 4/5: OR 20.26, p < 0.001; both compared with grades 1/2) and older age (≥ 75 years: OR 1.65, p = 0.025), but reduced over the study period (9% relative risk reduction per year). THR is a good option in patients aged < 75 years and with ASA 1/2. Cementation of the femoral component does not adversely affect peri-operative mortality but improves survival of the implant in the mid-term when compared with cementless femoral components. There are no benefits of using head sizes > 28 mm or bearings other than metal-on-polyethylene. More research is required to determine the benefits of THR over hemiarthroplasty in older patients and those with ASA grades > 2


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_13 | Pages 1 - 1
1 Jun 2017
Panagiotopoulou V Davda K Hothi H Henckel J Cerquiglini A Goodier W Skinner J Hart A Calder P
Full Access

Introduction. The Precice nail is the latest intramedullary lengthening nail with excellent early outcomes. Implant complications have led to modification of the nail design. The aim of this study was to perform a retrieval study of Precice nails following lower limb lengthening. To assess macroscopic and microscopic changes to the implants and assess differences following design modification, with identification of potential surgical, implant and patient risk factors. Method. 15 nails were retrieved from 13 patients following lower limb lengthening. Macroscopic and microscopic surface damage to the nails were identified. Further analysis included radiology and micro-CT prior to sectioning. The internal mechanism was then analysed with Scanning Electron Microscopy and Energy Dispersive X-ray Spectroscopy to identify corrosion. Results. 7 male and 3 females underwent 12 femoral lengthenings, 9 antegrade and 3 retrograde. 3 females underwent tibial lengthening. All patients obtained the desired length with no implant failure and full regenerate consolidation. Surface degradation was noted on the telescopic part of every nail design, less on the latest implants. Microscopic analysis confirmed fretting and pitting corrosion. Following sectioning black debris was noted in all implants. The early designs were found to have fractured actuator pins and the pin and bearings had evidence of corrosive debris. The latest designs had evidence of biological deposits suggestive of fluid ingress within the nail. Conclusion. This study suggests fluid ingress occurs with every generation of Precice nail despite modifications. The presence of biological fluid could be an early warning sign of potential corrosion. This in theory could lead to actuator pin fracture and implant failure. The clinical relevance is the potential re-use of a “dormant” nail in patients requiring secondary limb segment lengthening. Retraction of the nail in-situ and re-use for further lengthening requires careful consent for potential implant failure


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 231 - 231
1 Sep 2012
Chana R Esposito C Campbell P Walter W
Full Access

Background. Pseudotumours have been associated with metal-on-metal (MoM) hip replacements. We define it as a solid mass which may have cystic components that is neither neoplastic nor infectious in aetiology. The cause of a pseudotumour is not fully understood but could be due to excessive wear, metal hypersensitivity or due to an as-yet unknown cause. Aim. We present the retrieval analysis of early failure MoM hips revised for pain, loosening or a symptomatic mass. Tissues and implants were examined for the possible causes of failure and pseudotumour formation. Corrosion as a potential new cause for pseudotumour formation will be presented. Methods. A group of 16 MoM hip replacements were collected for retrieval analysis. Six of which had a pseudotumour. An Artificial Hip Profiler (Redlux Ltd) was used to measure wear. Edge loading was determined using the 3D wear data. Tissues were histologically evaluated using a 10-point ALVAL scoring system, which strongly suggests hypersensitivity (1). Cases were assigned to one of three categories: high wear (rates >5m/yr), hypersensitivity or corrosion. Results. Of the 6 pseudotumours, 3 had edge loading, 2 had high ALVAL scores and one had corrosion at the head taper junction. The high wear group, (3 cases) all demonstrated edge loading. Histology revealed more metal wear particles and macrophages, with a low ALVAL score in these cases. Two cases were found to have hypersensitivity with a high ALVAL score, more lymphocytes with less visible wear debris and macrophages. The wear rates were also lower, <4m/yr. One total hip replacement had corrosion at the junction between the head and adaptor taper for the stem. The bearings had low wear and the tissue had extensive necrosis as well as products of corrosion enclosed in fibrin (2). There was no suggestion of hypersensitivity (low ALVAL score). Conclusion. Pseudotumours can be caused by high wear, but if this is ruled out, a hypersensitivity or corrosion product reaction should be considered


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 572 - 572
1 Sep 2012
Khan A Ebreo D El Meligy M Armstrong C Peter V
Full Access

Introduction. The advantages of metal on metal (MOM) hip replacement are decreased wear rate, preservation of bone stock, anatomical restoration and enhanced stability. Large amounts of metal wear particles and metal ions are released which may induce adverse reactions including local soft tissue toxicity, hypersensitivity reactions, bone loss and risk of carcinogenesis. Aseptic loosening can be the result of a peri prosthetic osteolysis generated as a result of a biological response to particulate wear debris. Our aim in this study was to determine whether a steeply inclined acetabular component would give rise to a higher concentration of metal ions. Patients and methods. Between April 2003 and June 2006, 22 patients had MOM hip replacement for osteoarthritis by a single Surgeon. There were 12 male and 10 female patients. The average age at the time of surgery was 56 years (Range: 44–69 years). We divided the 22 patients into 2 groups, one group (A) of 11 patients with the acetabular inclination angle more than 50 degrees and the other group (B) of 11 patients with the angle less than 50 degrees. The inclination of the acetabular cup was measured using a standard AP radiograph of the pelvis. The patients had metal ion levels (blood chromium and serum cobalt) measured at an average follow up of 3.2 years (Range 2.4 to 5 years). Results. Mean blood chromium level in the group A (146 nM/L) was significantly higher (p=0.005) than in Group B (92 nM/L). Mean serum cobalt level in the group A (245 nM/L) was significantly higher (p=0.002) than in Group B (110 nM/L). Discussion. The early to mid term published results of MOM hip replacements have been encouraging. There are, however, a number of concerns about the MOM bearing. Although its wear rate is low, it still releases metal ions into the body particularly cobalt and chromium since most metal on metal bearings are made of a cobalt chromium alloy. The long-term consequences of increased levels of these ions in the body are not known. High concentrations of Co and Cr are toxic and are known to interfere with a number of biological functions. There also have been recent reports of soft tissue reactions with MOM hip replacement. In the light of these concerns, it is important to examine factors which may influence the release of metal ions after MOM hip replacement. It has been reported in the recent literature that the position of the acetabular component will influence the bearing wear inturn leading to the release of metal ions after MOM hip replacement. Our findings indicate that steeply inclined acetabular components with an inclination angle greater than 50 degrees gives rise to higher concentration of metal ions


Cemented total hip arthroplasty yields reliable results in short to medium term studies, but aseptic loosening remains a problem in long-term follow up, especially in young and active patients. Aseptic loosening has been related to wear, and in order to minimize wear various alternatives to the traditional metal on polyethylene have been proposed. Both ceramic on polyethylene (COP) and metal on metal (MOM) have been shown to produce less wear than metal on polyethylene (MOP). In order to study the effect of the bearing, we have utilized identical stems and cups while comparing the different bearings. Methods and material. 396 hips were randomized to MOP, COP or MOM using a cemented triple tapered polished stem (MS-30; Sulzer Orthopedics) with a cemented polyethylene cup (Weber; Sulzer, Orthopedics) and a 28 millimeter head. For the MOP and COP articulations, a all-polyethylene cup was used with a Protasul™ metal head or a Sulox™ alumina head, whereas a polyethylene cup with metal insert was used for the MOM articulations (Weber Polyethylene Cup with Metasul™ Insert) with a Metasul™ metal head. Harris Hip Score (HHS) and radiological evaluation was performed after two, five and seven years. Ethical approval was obtained. Results. HHS was available for 338 hips after seven years. The HHS in the MOP group (116 hips) was 93.7 (SD 9.0), 93.5 in the COP group (112 hips) (SD 8.8), and 91.0 (SD 13.4) in the MOM group (110 hips). Radiographic evaluation was available for 335 hips. Radiolucencies around the stem larger than one millimeter were found in five of 115 MOP hips, seven of 111 COP hips and in seven of 110 MOM hips. Periacetabular radiolucencies identified as larger than one millimeter were found in none of the 116 MOP hips, five of the 112 COP hips and in 19 of the 110 MOM hips. Ten revisions were performed. In the MOP group there were three revisions (infection, dislocation, pain); one in the COM group (infection), and six in the MOM group (three infections, two aseptic loosening and one septic loosening). Discussion. Clinically, the three bearing types perform equally well at seven years, and there are few signs of impending failure for the stem. However, there are an alarmingly high proportion of cups showing signs of loosening. Two hips have been revised in the MOM group for aseptic loosening as opposed to none in the two other groups, which adds to the concern. The MOM articulation used in this study should be monitored closely for signs of aseptic loosening


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 584 - 584
1 Sep 2012
Grammatopoulos G Thomas G Pandit H Glyn-Jones S Gill H Beard D Murray D
Full Access

INTRODUCTION. The introduction of hard-on-hard bearings and the consequences of increased wear due to edge-loading have renewed interest in the importance of acetabular component orientation for implant survival and functional outcome following hip arthroplasty. Some studies have shown increased dislocation risk when the cup is mal-oriented which has led to the identification of a safe-zone1. The aims of this prospective, multi-centered study of primary total hip arthroplasty (THA) were to: 1. Identify factors that influence cup orientation and 2. Describe the effect of cup orientation on clinical outcome. METHODS. In a prospective study involving seven UK centers, patients undergoing primary THA between January 1999 and January 2002 were recruited. All patients underwent detailed assessment pre-operatively as well as post-op. Assessment included data on patient demographics, clinical outcome, complications and further surgery/revision. 681 primary THAs had adequate radiographs for inclusion. 590 hips received cemented cups. The primary functional outcome measure of the study was the change between pre-operative and at latest follow up OHS (OHS). Secondary outcome measures included dislocation rate and revision surgery. EBRA was used to determine acetabular inclination and version. The influence of patient's gender, BMI, surgeon's grade and approach on cup orientation was examined. Four different zones tested as possibly ± (Lewinnek Zone, Callanan's described zone and zones ± 5 and ±10 about the study's mean inclination and anteversion) for a reduced dislocation risk and an optimal functional outcome. RESULTS. There were 21 dislocations (3.1%) and 8 (1.2%) patients required revision at a mean follow up of 7 years. Experienced surgeons (2=0.047) and those operating with the patient in the lateral decubitus position (p=0.04) were more likely to achieve a cup orientation within any of the tested zones. Surgical approach (2=0.14) and patient's BMI (2=0.93) had no influence on whether a cup was within or outside any zone. There was no difference in dislocation rate between the posterior and anterio-lateral approaches (2=0.88). None of the zones tested had a significantly reduced dislocation risk (2=0.13), nor revision risk (2=0.55). OHS was not different for patients with cups within or outside any of the zones tested (p=0.523). DISCUSSION. There was a wide variation in cup orientation. Despite the wide scatter in cup orientation, no safe zone could be identified that would reduce dislocation and revision rate, nor improve patient reported outcome (OHS). Hence, these data suggest that acetabular component orientation should not be considered predictive of patients' early/mid-term complication/revision rate and outcome following THA


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 341 - 341
1 Sep 2012
Bernstein M Desy N Huk O Zukor D Petit A Antoniou J
Full Access

Introduction. Metal-on-metal (MoM) articulations in total hip replacement (THR) have become an attractive option for young, active patients. Short-term reports have demonstrated elevated systemic metal ion levels in the blood and urine. Disseminated concentrations of cobalt and chromium have raised concern regarding cellular toxicity, chromosomal damage and adverse local soft tissue reactions. Long-term studies are required to support the increased use of MoM bearings in younger patients given their potential deleterious effects. The purpose of the current study was to report the 7–13 year clinical, radiographic, and metal ion results in patients following MoM THR. Methods. We prospectively followed 165 patients (196 hips) after second-generation MoM THR between July 1997 and November 2003. Functional outcome was measured using the Harris Hip Score (HHS) and the University of California Los Angeles (UCLA) Activity Score. Radiographic analysis was performed using Einzel-Bild-Roentgen-Analyse (EBRA) by two of the authors blinded to the study. Cobalt and chromium metal ions were measured from whole blood and analyzed using inductively coupled plasma-mass spectrometry. Results. 163 prostheses were analyzed. The mean age at surgery was 50.8 years (range, 17 to 66). There were 80 females and 83 males. The mean follow-up was 8.87 years (range, 7–13 years). Four hips (2.5%) were revised: 2 for infection at 0.2 and 7 years; 1 for a loose stem at 1.3 years; and 1 for a loose cup at 9 years. One patient received wound debridement for a superficial infection and did not have any components revised. The mean HHS and UCLA scores at the last follow-up were 91 and 6.8, respectively. The mean acetabular inclination and anteversion was 40 degrees (range, 24 to 57), and 19 degrees (range, 3 to 39), respectively. Median cobalt levels peaked at a value of 2.87 μg/L at 4 years (p<0.0001 vs. pre-operative) and subsequently decreased to 2.0 μg/L after 9 years (p=0.002 vs. 4-years). Median chromium levels maximally increased up to 0.75 μg/L after 5 years (p<0.0001 vs. pre-operative) and tended to decrease thereafter to values of 0.56 μg/L after 7 years. The Kaplan-Meier survivorship was 91.3% for revision for all causes, and 97.5% when excluding the hips revised for a manufacturer's defect at a mean of 8.87 years (range, 7–13 years). Conclusion. The present 7–13 years follow-up study of MoM THRs indicates that the clinical and radiological results are satisfactory with low revision rates. Furthermore, our study demonstrates the trend of metal ion levels in whole blood over a long-term. Both cobalt and chromium ion levels peaked at 4 and 5 years, respectively, and gradually decreased thereafter


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 222 - 222
1 Sep 2012
Li C Hussain A Pamu J Kamali A
Full Access

INTRODUCTION. Hip wear simulator test results could be affected by many non-bearing related factors such as fixation surface conditions, equipment calibration and component set-up. In an effort to improve the accuracy, reliability and repeatability of hip simulator test, a quality management system has been established at the IDC hip tribology laboratory, which has been accredited by UKAS (United Kingdom Accreditation Service) in accordance with the recognised international standard ISO17025. This study demonstrates that under well-controlled laboratory and testing conditions, satisfactory repeatability can be achieved during hip simulator studies. METHODS. Between 2008 to 2010, ten 50 mm Birmingham Hip Resurfacing (BHR) devices were tested by the IDC tribology laboratory using two ProSim hip wear simulators in three different tests (T1, T2 and T3). All tests were performed following the same IDC testing protocols at 1 Hz frequency for 5 million cycles (Mc) or until after a steady state was reached. Paul type stance phase loadings with a maximum load of 3 kN and a swing phase load of 0.3 kN was used. The flexion and extension angles were 30 and 15 degree. The internal/external rotation angel was ±10 degree. Wear was measured gravimetrically using an analytical balance (Mettler, Toledo xp504) with an accuracy of 0.1 mg. RESULTS. Results showed that wear of all the components tested followed the typical biphasic trend of wear for MoM hip joint device with a high “running-in” wear during the initial stage followed by a low “steady state” wear in the later stage. The data points scattered in a narrow range following the same trend line throughout the tests. The maximum difference in accumulated volume loss between any two tests at any given cycle was less in 0.2 mm3. The average running-in wear rates (±SD) were 0.72 ±0.17, 0.86 ±0.01 and 0.71 ±0.19 mm3/Mc respectively for test T1, T2 and T3. The running-in wear rates for test T1 and T3 were identical, whilst that for T2 was slightly higher. In spite of this, the wear rates for the bearings tested in T2 were still in the same range as those tested in T1 and T3 during the running-in stage. The steady state (>1.0Mc) wear rate of three different tests was practically the same, being 0.18 ±0.02, 0.18 ±0.06 and 0.16 ±0.04 mm3/Mc respectively for test T1, T2 and T3. Overall, the mean running-in wear rate was 0.74 ±0.16 mm3/Mc, and the steady state wear rate was 0.17 ±0.04 mm3/Mc for the 10 BHR devices tested in three different studies. DISCUSSIONS. This study shows that satisfactory repeatability can be achieved during hip simulator test of metal on metal hip joint devices. Well controlled test procedures including calibration of testing and measurement equipment, correct and consistence test set-up and attention to non-bearing surfaces are some of the most important prerequisites for reliable and accurate hip simulator test results