Advertisement for orthosearch.org.uk
Results 1 - 20 of 128
Results per page:
Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 583 - 583
1 Sep 2012
Walker C Gulati A Bhatia M
Full Access

Introduction/Aim. Thromboembolism is a significant cause of patient morbidity and mortality, the risk of which increases in orthopaedic patients with lower limb immobilisation. It was therefore, our aim to identify a difference in symptomatic thromboembolism by treating acute Achilles tendon rupture patients with conventional non-weight bearing plaster versus functional weight bearing mobilisation. Methodology. The notes of 91 consecutive patients with acute Achilles tendon rupture were reviewed. The patients demographics, treatment modality (non-weight bearing plaster versus weight bearing boot), and predisposing risk factors were analysed. From the 91 patients, 50 patients with acute Achilles tendon rupture were treated conservatively in a non-weight bearing immobilisation cast. From these 50 patients, 3 then underwent surgery and were therefore excluded from the results. 41 patients were treated with functional weight bearing mobilisation. Patients who did have a symptomatic thromboembolic event had an ultrasound scan to confirm a deep vein thrombosis of the lower limb, or a CT-scan to confirm pulmonary embolism. Results. Out of the 47 patients who were treated conservatively in a non-weight bearing plaster cast, 9 patients (19.1 %) had a thromboembolic event. Out of the 41 patients who were treated with functional weight bearing mobilisation, 2 patients (4.8%) had a thromboembolic event. Thus, patients who were treated in a non-weight bearing plaster had a significantly higher risk of developing thromboembolism (p value of <0.05) and an increased risk ratio of 24% compared to those who were treated with functional weight bearing mobilisation. Conclusion. There is a significant decrease in the clinical incidence of thromboembolic events in patients treated conservatively with early mobilisation in the functional weight bearing boot compared to those treated in a non-weight bearing cast


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_14 | Pages 7 - 7
10 Oct 2023
Chambers M Madeley N
Full Access

Stable Weber B fractures are typically treated non-operatively without complications but require close monitoring due to concerns over potential medial deltoid ligament injuries and the risk of delayed talar shift. Following recent evidence suggesting this is unlikely, a functional protocol with early weight bearing was introduced at Glasgow Royal Infirmary (GRI) following a pilot audit. This study aims to evaluate the risk of delayed talar shift in isolated Weber B fractures managed with functional bracing and early weight-bearing, particularly if signs of medial ligament injury are present. We conducted a retrospective review of 148 patients with isolated Weber B fractures without talar shift at presentation that were reviewed at the virtual fracture clinic at our institution between July 2019 and June 2020. The primary outcome was the incidence of delayed talar shift. Secondary outcomes were other complications and adherence to protocol. 48 patients had medial signs present and of these 1 (2%) showed possible talar shift on X-rays at 4 weeks, and was kept under review. This patient had a normal medial clear space at 3 months. No patients with medial signs not documented (n=19) or not present (n=81) had delayed talar shift. 10% of patients (n=15) had at least 1 complication: delayed union (n=2); non-union (n=3); ongoing pain (n=14). Functional bracing with early weight-bearing is a safe, effective protocol for managing isolated Weber B fractures without initial talar shift. This study concludes that the risk of delayed talar shift is low in all patients, with or without medial signs


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_8 | Pages 18 - 18
1 May 2018
Williamson M Iliopoulos E Jain A Ebied W Trompeter A
Full Access

Background. There exists no consensus opinion as to the most suitable post-operative rehabilitation and weight bearing status for proximal tibia articular fractures treated with internal fixation using plates and screws. Objectives. The aim of this study is to investigate whether the post-operative weight bearing status is associated with loss of reduction and articular collapse. Study Design and Methods. Data was retrospectively analysed from our prospective database in a major trauma centre. Group I were non-weight bearing for the first six weeks post-operation and Group II were instructed to weight bear fully immediately post-operation. Radiographs were taken day one post-operation, at six weeks and at three months and analysed for fracture displacement and joint depression or loss of fixation. Results. 90 patients were included in the study. The follow up radiographs demonstrated no failure of fixation in either study group. One patient from the weight bearing group had >1mm joint depression (4mm) identified at the first follow up, which did not worsen by the second. Conclusions. This study shows immediate post-operative full weight bearing does not affect the fixation or cause articular collapse up to three months after surgery. We propose that patients should be encouraged to weight bear immediately post-operation


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_8 | Pages 32 - 32
1 May 2018
Iliopoulos E Ads T Trompeter A
Full Access

Introduction. Plate fixation for distal femoral fractures is a commonly used method of fracture stabilisation. Many orthopaedic surgeons traditionally do not allow their patients to weight bear for the first 6 weeks after surgery, fearing of loss of fracture reduction and metalwork failure. The aim of this study is to investigate whether the post-operative weight bearing status after plate fixation influences the outcome in terms of loss of reduction and metalwork failure. Materials & Methods. A retrospective data collection from all patients who treated in our hospital surgically for distal femoral fractures, from January 2015 until June 2017. Inclusion criteria were the operative treatment of these fractures with plate fixation. Patients who were treated with retrograde nail, primary total knee replacement or screw fixation were excluded from the study. Patient, injury and surgery demographic data was collected. The immediate post-operative weight bearing status of these patients was noted. Weight bearing status was divided into two groups – Group 1 (Non and touch weight bear – the non-weight bearing group) and Group 2 (Weight bear as tolerated / Full weight bear – the weight bearing group). Radiological data about fracture displacement or metalwork failure was collected at the six weeks and three months follow up after the operation, using a standardised measurement for displacement performed independently by two authors (EI, TA). Results. Of 70 patients, a total of 51 fractures treated with plate fixation were included to the study. The mean age of the cohort was 64.3 ±20.7 years with the majority of the patients being female (63%). Most of the patients (40%) had a complete articular distal femoral fracture, AO Type 33C. Thirty-nine patients (76%) were treated with one lateral distal femoral plate. The total number of the patients in group 1 was 32 (68%); with 17 patients (32%) in group 2. The weight bearing status did not correlate with the fracture type or the fixation type (p>0.05). None of the 6 weeks follow up radiographs revealed fracture displacement in both study groups. Four of the patients from the non-weight bearing group had >1mm displacement at the 3 months' follow-up radiographs. Fisher's exact test revealed no statistically significant difference between the two study groups in both follow-up time points (p=0.55). Two of the patients in the non-weight bearing group had their plate broken at the 3 months follow up and required revision fixation. Conclusion. By reviewing the outcomes in terms of fracture displacement and metalwork failure following plate fixation of distal femoral fractures, early weight bearing of these patients do not jeopardise the outcome of the operation


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 142 - 142
1 Sep 2012
Traynor A Simpson D Ellison P Collins S
Full Access

Introduction. Cobalt chrome on polyethylene remains a widely used bearing combination in total joint replacement. However wear induced osteolysis, bulk material property degradation of highly cross-linked polyethylene (HXLPE) [1], and oxidation after implantation (thought to be as a result of lipid absorption or cyclic loading [2]) remains a concern. ECIMA is a cold-irradiated, mechanically annealed, vitamin E blended next generation HXLPE developed to maintain mechanical properties, minimise wear and to improve the oxidation resistance in the long-term. The aim of this study was to compare the in-vitro wear rate and mechanical properties of three different acetabular liners; conventional UHMWPE, HXLPE and ECIMA. Methods. Twelve liners (Corin, UK) underwent a 3 million cycle (mc) hip simulation. Three conventional UHMWPE liners (GUR1050, Ø32 mm, 30 kGy sterilised in Nitrogen), three HXLPE liners (GUR1020, Ø40 mm, 75 kGy cross-linking and EtO sterilised) and six ECIMA liners (0.1 wt% vitamin E GUR1020, Ø40 mm, 120 kGy cross-linking, mechanically deformed and annealed, and EtO sterilised) articulated against CoCrMo alloy femoral heads to ASTM F75 (Corin, UK). Wear testing was performed in accordance with ISO 14242 parts 1 and 2, with a maximum force of 3.0 kN and at a frequency of 1 Hz. The test lubricant used was calf serum with a protein content of 30 g/l and 1% (v/v) patricin added as an antibacterial agent. Volumetric wear rate was determined gravimetrically after the first 0.5 mc and every 1 mc thereafter. ASTM D638 type V specimens (3.2 mm thick) were machined from ECIMA material for uniaxial tension testing to ASTM D638. Ultimate tensile strength (UTS), yield strength and elongation values were measured. These values were compared to mechanical data available for the other material types. Results. There was a 94% and a 68% reduction in the wear rate for the ECIMA liners compared to the conventional UHMWPE and HXLPE liners respectively. There was an increase in UTS, yield strength and elongation of 11%, 11% and 15% respectively, for ECIMA compared to HXLPE. Discussion. The wear results reported in this study indicate that ECIMA is a very low wearing material which has the potential to reduce wear related osteolysis in-vivo. Importantly, the mechanical properties were generally maintained unlike the degradation found in many modified polyethylene materials and were more comparable to conventional UHMWPE than HXLPE. The reduced wear rate during in-vitro hip simulation of ECIMA compared to conventional UHMWPE, coupled with improved mechanical properties in comparison to HXLPE, makes ECIMA a promising next generation, advanced bearing material


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 271 - 271
1 Sep 2012
Jenny J Saussac F Louis P
Full Access

INTRODUCTION. Computer-aided systems have been developed recently in order to improve the precision of implantation of unicompartmental knee replacement (UKR). Minimal invasive techniques may decrease the surgical trauma related to the prosthesis implantation, but there might be a concern about the potential for a loss of accuracy. Mobile bearing prostheses have been developed to decrease the risk of polyethylene wear, but are technically more demanding. Navigation might help to compensate for these difficulties. We wanted to combine the theoretical advantages of the three different techniques by developing a navigated, minimal invasive, mobile bearing unicompartmental knee prosthesis. MATERIAL AND METHODS. 160 patients have been operated on at our institution with this system. The 81 patients with more than 2 year follow-up have been re-examined. Complications have been recorded. The clinical results have been analyzed according to the Knee Society Scoring System. The subjective results have been analyzed with the Oxford Knee Questionnaire. The accuracy of implantation has been analyzed on post-operative antero-posterior and lateral long leg X-rays. The 2-year survival rate has been calculated. RESULTS. We observed 8 complications related to the implant or the operative technique: 2 cases of meniscus instability (1 revision to TKR, 1 bearing exchange); 2 cases of tibia loosening (revised to TKR), 2 cases of femoral loosening (revised to TKR), 1 case of lateral disease progression (revised to TKR), 1 case of unexplained pain syndrome (revised to TKR). The mean Knee Score was 93 points, 44% had the maximum of 100 points, and only 10% have less than 85 points. The mean pain score was 48 points/50. The mean flexion angle was 128°, and 60% had at least 130° of knee flexion. The mean Function Score was 97 points, 84% have the maximum of 100 points, and only 5% had less than 85 points. The mean Oxford Knee Questionnaire score was 19 points (best result: 12 points, worst result: 60 points). Expected limb axis correction was obtained in 77% of the cases. 62% of the cases had an optimally implanted prosthesis for all studied criteria. The 2-year survival rate was 97%. DISCUSSION. Most of the revision cases were related to technical difficulties during the development phase. Fixation of the implant has been improved, and some imprecise steps of the software have been corrected. Since these changes occurred, no severe early complication related to implant or software has been observed. The current implant is considered reliable, and the current minimal invasive navigated technique is considered reliable as well


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 549 - 549
1 Sep 2012
Pengas I Pillai A Gayed W Assiotis A Mcnicholas M
Full Access

The patella is a complex sesamoid bone within the quadriceps enhancing mechanical advantage of the extensor mechanism. Depending on activity, the patella magnifies either force or displacement; behaving as a lever, by redirecting quadriceps force it also acts as a pulley. Aim. We describe and validate a device for obtaining consistent dynamic weight bearing views of the patellofemoral joint (PFJ). Materials and Methods. Weight bearing (WB) axial views of 48 knees (24 patients) were performed using the device. The sulcus angle (SA), congruence angle (CA), lateral patellofemoral angle (LPFA), facet angle (FA) and patellofemoral displacement (PD) were measured. These were compared with similar measurements made on prone (PR) and axial (AX) radiographs of same knees. Results. Variance (V=SD2) and Standard error of mean (SEM/95% CI) for all measurements in each of the three views were analysed. For the Sulcus Angle, Congruence angle and LPFA, the WB view had the lowest SEM and the least variance in comparison to PR and AX views (SEM 1.05/V 30.14, SEM 2.52/V 172.39 and SEM 1.34/V 47.61 respectively for the SA, SEM 3.09/V 256, SEM 2.79/V 210.25 and SEM 3.37/V 306.25 respectively for the CA, SEM 0.67/V 11.9, SEM 1.20/V39.06 and SEM 1.03/V 28.83 respectively for the LPFA). SEM and Variance for FA measurements were similar for WB and AX views but superior to PR views (SEM 1.62/V 70.56, SEM 1.6/V 68.9 and SEM 2.3/V 148.84 respectively). Mean PFD was maximum on the WB view compared to the PR and AX views (36.0, −45.62 and 22.23 respectively) with lowest SEM and V (SEM 8.73/V 2052.0, SEM 18.65/V 92959.67 and SEM 9.70/V 2540.16 respectively). Conclusion. The WB view as introduced and reported here has consistently lower Variance, SEM and SD in comparison to Axial and Prone views for all measurements of the PFJ. WB view also gives a more accurate dynamic measure of Patello Femoral displacement. The view is easily obtained and readily reproduced


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 333 - 333
1 Sep 2012
Essig J Nourissat C Asencio G
Full Access

The use of a total hip arthroplasty with alumina on alumina bearing couple should limit the risk of wear and secondary osteolysis. From June 1999 to December 2002, we have realised a continuous series of 265 ABGII cementless THA with Alumina bearing. The average age was 58 years (22–78 years). The main causes were osteoarthritis (81%) and osteonecrosis (13%). The operation was performed through a posterior standard approach. In all cases, an anatomic cementless ABG II stem and an acetabular cementless ABG II cup were implanted. The bearing couple was always Alumina Biolox Forte with a 28 mm femoral head in 99% of cases. To date, 12 patients died and 17 patients were lost to follow up (6.4%). 224 patients (232 hips) had a regular clinical and radiological follow-up. The mean follow up was 8.5 years (5–11 years). 9 patients were revised for septic loosening (4cases), femoral fracture (4 cases) and inveterate dislocation (1 case). There was no aseptic loosening. The overall survival rate at more than 10 years is 96.6%. We deplore 2 cases of postoperative dislocation. In this series, we did not observe any breakage of ceramic implant. The clinical and functional outcome is good and stable over time with an average PMA score at 17.6 and an average Harris score at 97.3. 16 patients reported at least one or more episode of abnormal noise “Squeaking” type (6%). It is most often a mild noise and it occurs in a static bending position. This noise disappeared with time in 10 cases. It never necessitated a prosthetic revision. The radiological control does not show any wear. There is no evidence of acetabular or femoral osteolysis. The radiological implant fixation according to the Engh and ARA criteria was good and stable in all cases. This series demonstrate that the implantation of an anatomic cementless HA arthroplasty with an alumina bearing in a young and active patient prevents the risk of wear and osteolysis and improves durability over time. The use of a 28 mm head does not increase the risk of instability and we did not observe failure of the ceramic implants


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 39 - 39
1 Sep 2012
Lee MC Lee SM Seong SC Lee S Jang J Lee JK Shim SH
Full Access

Summary. UC TKA showed similar anteroposterior translation and more femoral external rotation of earlier onset when compared to PS TKA. Introduction. Recently highly conforming ultracongruent TKA has been reintroduced with improved wear characteristics and lower complications. The purpose of the study was to assess kinematics and clinical outcome of posterior stabilized and ultracongruent rotating-platform mobile bearing TKA. Methods. Ninety patients with primary osteoarthritis of the knee were randomized to undergo computer assisted TKA with PS(n = 45) or UC(n = 45) prostheses and were followed up for a minimum 2 years. The passive kinematic evaluation was performed before and after implantation with a navigation system. Three parameters of tibiofemoral relationship (anterior/posterior translation, varus/valgus alignment and rotation) were recorded from 0° to 120° of flexion. The patients were clinically and radiographically evaluated at final follow-up. Results. Paradoxical anterior translation of the femur was observed from 0° to 70° of flexion in PS(8.7mm) and 0° to 85° in UC knees(10.4mm, p = 0.064). The distance of femoral roll-back was 6.7mm and 5.5mm, but never reached the starting point. Paradoxical internal rotation of the femur was found from 0° to 62° of flexion in PS(9.9°) and 0° to 47° in UC knees(5.6°, p = 0.002). UC knees showed more external rotation of the femur during flexion from 0° to 120°(5.7:11.0, p = 0.048). There was no significant difference in the maximal flexion(123.3°:125.5°, p = 0.366), AKS knee scores(95.9:92.0, p = 0.101), AKS function scores(86.2:82.9, p = 0.435) and WOMAC index scores(13.4:15.9, p = 0.268). There was no progressive radiolucent line or loosening in all knees. Discussion and Conclusion. UC TKA showed similar anteroposterior translation and more femoral external rotation of earlier onset when compared to PS TKA. There was no difference in clinical outcome between two designs. UC TKA showed comparable kinematic and clinical results to PS TKA


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_4 | Pages 14 - 14
1 May 2015
Bugler K White T
Full Access

Early weight-bearing of patients with ankle fractures is associated with good outcomes. There are a number of potential advantages to early mobilisation including reduced hospital stay and earlier return to work and regular daily activities. However, many surgeons have not incorporated this into their routine ankle fracture protocol, particularly for patients managed operatively; potentially due to concerns regarding loss of reduction. We hypothesised that ankle fractures managed fully weight-bearing would have good outcomes and a low rate of loss of reduction.

All ankle fractures presenting to our department over a 15-month period were studied prospectively. Patients were instructed to mobilise fully weight-bearing as able, either immediately postoperatively (for those fractures considered unstable that underwent operative intervention), or at the first fracture clinic review (if stable and managed conservatively). Only patients with syndesmotic injuries and those with neuropathy or psychiatric illness were excluded. The effectiveness of this management protocol was assessed by clinical and radiographic review following fracture union.

847 patients were included, of whom 25% were over the age of 65. 33% of fractures were unstable and therefore managed operatively, 66% were stable and therefore managed in casts or with functional bracing. In every case the radiographs showed maintenance of anatomical mortise and fracture reduction at the time of union, good patient reported outcomes were also recorded.

Early weight-bearing of patients with ankle fractures, whether managed conservatively or operatively, results in very low rates of loss of reduction and should be considered routine management for the majority of patients.


Cemented total hip arthroplasty yields reliable results in short to medium term studies, but aseptic loosening remains a problem in long-term follow up, especially in young and active patients. Aseptic loosening has been related to wear, and in order to minimize wear various alternatives to the traditional metal on polyethylene have been proposed. Both ceramic on polyethylene (COP) and metal on metal (MOM) have been shown to produce less wear than metal on polyethylene (MOP). In order to study the effect of the bearing, we have utilized identical stems and cups while comparing the different bearings. Methods and material. 396 hips were randomized to MOP, COP or MOM using a cemented triple tapered polished stem (MS-30; Sulzer Orthopedics) with a cemented polyethylene cup (Weber; Sulzer, Orthopedics) and a 28 millimeter head. For the MOP and COP articulations, a all-polyethylene cup was used with a Protasul™ metal head or a Sulox™ alumina head, whereas a polyethylene cup with metal insert was used for the MOM articulations (Weber Polyethylene Cup with Metasul™ Insert) with a Metasul™ metal head. Harris Hip Score (HHS) and radiological evaluation was performed after two, five and seven years. Ethical approval was obtained. Results. HHS was available for 338 hips after seven years. The HHS in the MOP group (116 hips) was 93.7 (SD 9.0), 93.5 in the COP group (112 hips) (SD 8.8), and 91.0 (SD 13.4) in the MOM group (110 hips). Radiographic evaluation was available for 335 hips. Radiolucencies around the stem larger than one millimeter were found in five of 115 MOP hips, seven of 111 COP hips and in seven of 110 MOM hips. Periacetabular radiolucencies identified as larger than one millimeter were found in none of the 116 MOP hips, five of the 112 COP hips and in 19 of the 110 MOM hips. Ten revisions were performed. In the MOP group there were three revisions (infection, dislocation, pain); one in the COM group (infection), and six in the MOM group (three infections, two aseptic loosening and one septic loosening). Discussion. Clinically, the three bearing types perform equally well at seven years, and there are few signs of impending failure for the stem. However, there are an alarmingly high proportion of cups showing signs of loosening. Two hips have been revised in the MOM group for aseptic loosening as opposed to none in the two other groups, which adds to the concern. The MOM articulation used in this study should be monitored closely for signs of aseptic loosening


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 260 - 260
1 Sep 2012
Berizzi A Zanarella S Lelio E Aldegheri R
Full Access

Introduction

treatment of femoral neck fractures in the physically active elderly, is still an open question. The comparison of total replacement and partial hip replacement showed substantial superiority of the first approach than the latter. We can not disregard the problems that THR can lead in the elderly: more surgical time, greater blood loss, major sacrifice of bone in osteoporotic subjects. The Tribofit® acetabular system, has the objective to overcome these problems with the implantation of a single 3mm soft, pliable buffer made of polycarbonate-urethane between the large diameter metal femoral head and the subchondral bone, thus replacing the articular cartilage. The surgical technique includes the reaming of the cartilage layer, the creation of a circumferential groove and the snap-fit insertion of the buffer.

The purpose of the prospective study was to evaluate the effectiveness of this approach in the treatment of femoral neck fractures in the elderly.

Materials and Methods

from September 2008 to July 2010 we performed 45 implants with the Tribofit® Acetabular Buffer (Active Implants®, Memphis TN, USA). The inclusion criteria for the study were: femoral neck fracture patients over 75 years of age, physically independent before the injury, with good life expectancy, mild or absent arthritis, absence of morphological alterations of the acetabulum. The average age of these patients was 81,2 (75–89), the sex distribution was 36 females and 9 males, with 22 fractures of the left hip and 23 of the right. In all cases an uncemented straight femoral stem was implanted.

We recorded per-operative blood loss and intra-per-operative problems encountered. Follow-up were performed at 1, 3, 6 and 12 months post-op with radiographic control and clinical examination. The clinical outcome was objectively measured by the Harris Hip Score, pain Visual Analogue Scale and SF-36 questionnaire.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_4 | Pages 7 - 7
8 Feb 2024
Martin DH Ng N Armstong B Brennan J Feng T Lekuse K White TO Mackenzie SP
Full Access

Myriad protocols exist for isolated Weber B lateral malleolus fractures with a congruent tibiotalar joint on initial radiographs. Stress and weight-bearing radiographs, all at various timepoints, may be employed to identify those injuries that develop significant talar shift but consensus is elusive. This study outlines a safe and reproducible protocol for such injuries, utilising a removable orthosis, immediate weight bearing and standard supine radiographs. A retrospective analysis of a prospective trauma database was analysed to identify patients with an isolated Weber B ankle fracture with adequate presentation radiographs demonstrating a congruent mortise. Patient records and radiographs were evaluated a minimum of 5 years after initial presentation to determine ankle stability, complications, and the burden on outpatient services. Between 2014 and 2016, 657 patients were referred to the specialist trauma clinic from the emergency department. Of the 657, 52 patients had inadequate ED radiographs to determine ankle congruity. At the two-week assessment, 11 of the 52 demonstrated talar shift and required intervention. Therefore 646 patients demonstrated ankle congruity at two weeks after weight bearing. No patient demonstrated talar shift at the six-week assessment. Average number of follow up appointments was 2.4 with 3.5 radiographs. Our new treatment protocol advocates discharge after a single orthopaedic assessment after two weeks of weight bearing. This study supports immediate weight-bearing of Weber B ankle fractures with a congruent mortise in an orthosis. Follow up beyond two weeks is unnecessary and our protocol offers a safe means of significantly reducing the outpatient burden


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_12 | Pages 10 - 10
1 Oct 2021
Zein A Elhalawany AS Ali M Cousins G
Full Access

Despite multiple published reviews, the optimum method of correction and stabilisation of Blount's disease remains controversial. The purpose of this study is to evaluate the clinical and radiological outcomes of acute correction of late-onset tibial vara by percutaneous proximal tibial osteotomy with circular external fixation using two simple rings. This technique was developed to minimise cost in a context of limited resources. This study was conducted between 2016 and 2020. We retrospectively reviewed the clinical notes and radiographs of 30 patients (32tibiae) who had correction of late-onset tibia by proximal tibial osteotomy and Ilizarov external fixator. All cases were followed up to 2 years. The mean proximal tibial angle was 65.7° (±7.8) preoperatively and 89.8° (±1.7) postoperatively. The mean mechanical axis deviation improved from 56.2 (±8.3) preoperatively to 2.8 (±1.6) mm postoperatively. The mean femoral-tibial shaft angle was changed from – 34.3° (±6.7) preoperatively to 5.7° (±2.8) after correction. Complications included overcorrection (9%) and pin tract infection (25%). At final follow up, all patients had full knee range of motion and normal function. All cases progressed to union and there were no cases of recurrence of deformity. This simple procedure provides secure fixation allowing early weight bearing and early return to function. It can be used in the context of health care systems with limited resources. It has a relatively low complication rate. Our results suggest that acute correction and simple circular frame fixation is an excellent treatment choice for cases of late-onset tibia vara, especially in severe deformities


Bone & Joint Open
Vol. 5, Issue 3 | Pages 236 - 242
22 Mar 2024
Guryel E McEwan J Qureshi AA Robertson A Ahluwalia R

Aims

Ankle fractures are common injuries and the third most common fragility fracture. In all, 40% of ankle fractures in the frail are open and represent a complex clinical scenario, with morbidity and mortality rates similar to hip fracture patients. They have a higher risk of complications, such as wound infections, malunion, hospital-acquired infections, pressure sores, veno-thromboembolic events, and significant sarcopaenia from prolonged bed rest.

Methods

A modified Delphi method was used and a group of experts with a vested interest in best practice were invited from the British Foot and Ankle Society (BOFAS), British Orthopaedic Association (BOA), Orthopaedic Trauma Society (OTS), British Association of Plastic & Reconstructive Surgeons (BAPRAS), British Geriatric Society (BGS), and the British Limb Reconstruction Society (BLRS).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 358 - 358
1 Sep 2012
Gulati A Walker C Bhatia M
Full Access

Introduction. Venous thromboembolism (VTE) is a significant cause of patient morbidity and mortality, the risk of which increases in orthopaedic patients with lower limb immobilisation. This incidence should in theory reduce if the patients are ambulatory early in the treatment phase. The aim of this study was, therefore, to identify a difference in the incidence of symptomatic VTE by treating acute Achilles tendon rupture patients with conventional non-weight bearing plaster versus functional weight bearing mobilisation. Methodology. The notes of 91 consecutive patients with acute Achilles tendon rupture were retrospectively reviewed and prospectively followed. The patients' demographics, treatment modality (non-weight bearing plaster versus weight bearing boot), and the type of plaster immobilisation was compared to assess whether they affect the incidence of clinical VTE. The predisposing risk factors were also analysed between the treatment groups. Out of 91 patients, 50 patients with acute Achilles tendon rupture were treated conservatively in a conventional non-weight bearing immobilisation cast. From these 50 patients, 3 then underwent surgery and were therefore excluded from the results. On the other hand, 41 patients were treated with functional weight bearing mobilisation (Vacupad). Patients who did have a symptomatic thromboembolic event also had an ultrasound scan to confirm a deep vein thrombosis of the lower limb or a CT-scan to confirm pulmonary embolism. Results. Out of the 47 patients who were treated conservatively in a non-weight bearing plaster cast, 9 patients had a thromboembolic event (19.1%). On the other hand, out of the 41 patients who were treated with functional weight bearing mobilisation, only 2 patients had a symptomatic thromboembolic event (4.2%). This was statistically significant (p=0.012). This shows that patients who are treated in a non-weight bearing plaster have about five times increased risk of developing a sypmptomatic VTE compared to those treated by functional weight bearing mobilisation. There was however no difference in the predisposing factors in patients who developed VTE compared to those who did not. Conclusion. The incidence of symptomatic VTE after acute Achilles tendon rupture is high and under-recognised. Asymptomatic VTE after this injury is probably even higher. There is a significant decrease in the clinical incidence of thromboembolic events in patients treated conservatively with early mobilisation in the functional weight bearing boot compared to those treated in a non-weight bearing cast. There is a need for further research to define the possible benefit of thromboprophylaxis in patients treated by non-weight bearing plasters


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_8 | Pages 45 - 45
1 May 2018
Jahangir N Umar M Rajkumar T Davis N Alshryda S Majid I
Full Access

Purpose of study. To review the treatment and outcomes of paediatric pelvic ring injuries in the UK. Methods and results. We performed a retrospective review of all pelvic fracture admissions to an English paediatric major trauma centre (MTC) from 2012 to 2016. A total of 29 patients were admitted with pelvic ring injuries with a mean age of 11 years (4- 16yrs). Road traffic accident was the mechanism in majority (72%), followed by fall from height (24%). Femoral shaft fracture was present in 5 (17%), head injury in 5 (17%), chest injuries in 5 (17%) and bladder injury in one child. 48% patients needed surgical procedures for fractures or associated injuries. We differentiated injuries according to the classification system of Torode and Zeig. 17% were Type A, 3% Type B, 48% Type C and 31% Type D. Almost all (93%) patients were treated conservatively. 51% of patients were allowed to mobilize full weight bearing after a period of bed rest. Non-weight bearing mobilization was recommended for fractures extending into the acetabulum, sacral fractures, unstable fracture patterns or associated fractures (neck of femur, femoral shaft and tibial shaft). Surgical fixation occurred in two patients. Both of these patients had significantly displaced Type D fractures. Only 44% of patients were back to sports at six months. Conclusions. Pelvic ring injuries are rare within the paediatric population and are associated with a high incidence of concomitant injury and significant functional morbidity. Their treatment should involve a multidisciplinary approach, which includes specialist in the care of pelvic trauma


The Bone & Joint Journal
Vol. 104-B, Issue 2 | Pages 283 - 289
1 Feb 2022
Cerbasi S Bernasconi A Balato G Dimitri F Zingaretti O Orabona G Pascarella R Mariconda M

Aims

The aims of this study were to assess the pre- and postoperative incidence of deep vein thrombosis (DVT) using routine duplex Doppler ultrasound (DUS), to assess the incidence of pulmonary embolism (PE) using CT angiography, and to identify the factors that predict postoperative DVT in patients with a pelvic and/or acetabular fracture.

Methods

All patients treated surgically for a pelvic and/or acetabular fracture between October 2016 and January 2020 were enrolled into this prospective single-centre study. The demographic, medical, and surgical details of the patients were recorded. DVT screening of the lower limbs was routinely performed using DUS before and at six to ten days after surgery. CT angiography was used in patients who were suspected of having PE. Age-adjusted univariate and stepwise multiple logistic regression analysis were used to determine the association between explanatory variables and postoperative DVT.


Bone & Joint Open
Vol. 2, Issue 11 | Pages 958 - 965
16 Nov 2021
Craxford S Marson BA Nightingale J Ikram A Agrawal Y Deakin D Ollivere B

Aims

Deep surgical site infection (SSI) remains an unsolved problem after hip fracture. Debridement, antibiotic, and implant retention (DAIR) has become a mainstream treatment in elective periprosthetic joint infection; however, evidence for DAIR after infected hip hemiarthroplaty is limited.

Methods

Patients who underwent a hemiarthroplasty between March 2007 and August 2018 were reviewed. Multivariable binary logistic regression was performed to identify and adjust for risk factors for SSI, and to identify factors predicting a successful DAIR at one year.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_5 | Pages 7 - 7
1 May 2015
Olesen UK Paulsen AW Bosemark P Eckardt H
Full Access

Background:. Segmental defects of long bones are notoriously demanding and difficult to treat. We evaluate nine cases where the Masquelet induced membrane technique to substitute bone loss has been used. We discuss the method compared to other types of bone reconstruction and share our tips and tricks to reduce treatment time and improve patient comfort. Method:. Eight patients (nine injuries) operated between 2011 and 2014 were included. Four were infected. Outcome was time-to weight-bearing, consolidation, complications, bone grafting. Results:. All patients were weight bearing fully after 270 days. Mean time to weight bearing was 225 days. Time to full weight bearing was shorter in patients where nails were used to stabilize the construct: median 115 (range 0–268) compared to plates: median 244 (range 219–271). All but two cases went on to full consolidation. Three cases needed grafting, one was misaligned. There were no amputations, no persistent infections, and no implant failures. Discussion:. The induced membrane technique is a relevant alternative to traditional bone substitution in select cases, yet somewhat unpredictable in its course and prolonged immobilisation is often required. Conclusion:. Nailing seems to improve the outcome by reducing treatment time and volume of bone graft needed and should be considered when feasible