Advertisement for orthosearch.org.uk
Results 1 - 20 of 473
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 5 | Pages 660 - 662
1 May 2012
Aldridge SE Heilpern GNA Carmichael JR Sprowson AP Wood DG

Incomplete avulsion of the proximal hamstrings can be a severely debilitating injury that causes weakness, pain while sitting and inability to run. The results of the surgical treatment of 23 consecutive patients with such injuries at least two years after surgery are described. The surgery consisted of the repair of the hamstrings directly onto the ischial tuberosity. At review, using a visual analogue scale (VAS, 0 to 100), pain while sitting improved from a mean of 40 (0 to 100) to 64 (0 to 100) (p = 0.024), weakness from a mean of 39 (0 to 90) to 76 (7 to 100) (p = 0.0001) and the ability to run from a mean of 24 (0 to 88) to 64 (0 to 95) (p = 0.0001). According to a VAS, satisfaction was rated at a mean of 81 (0 to 100) and 20 patients (87%) would have the same procedure again. Hamstring strength measured pre- and post-operatively had improved significantly from a mean of 64% (0% to 95%) to 88% (50% to 114%) compared with the normal side. Most of these patients with symptomatic incomplete hamstring avulsions unresponsive to conservative treatment had an improved outcome after surgical repair


Bone & Joint Research
Vol. 11, Issue 8 | Pages 575 - 584
17 Aug 2022
Stoddart JC Garner A Tuncer M Cobb JP van Arkel RJ

Aims. The aim of this study was to determine the risk of tibial eminence avulsion intraoperatively for bi-unicondylar knee arthroplasty (Bi-UKA), with consideration of the effect of implant positioning, overstuffing, and sex, compared to the risk for isolated medial unicondylar knee arthroplasty (UKA-M) and bicruciate-retaining total knee arthroplasty (BCR-TKA). Methods. Two experimentally validated finite element models of tibia were implanted with UKA-M, Bi-UKA, and BCR-TKA. Intraoperative loads were applied through the condyles, anterior cruciate ligament (ACL), medial collateral ligament (MCL), and lateral collateral ligament (LCL), and the risk of fracture (ROF) was evaluated in the spine as the ratio of the 95. th. percentile maximum principal elastic strains over the tensile yield strain of proximal tibial bone. Results. Peak tensile strains occurred on the anterior portion of the medial sagittal cut in all simulations. Lateral translation of the medial implant in Bi-UKA had the largest increase in ROF of any of the implant positions (43%). Overstuffing the joint by 2 mm had a much larger effect, resulting in a six-fold increase in ROF. Bi-UKA had ~10% increased ROF compared to UKA-M for both the male and female models, although the smaller, less dense female model had a 1.4 times greater ROF compared to the male model. Removal of anterior bone akin to BCR-TKA doubled ROF compared to Bi-UKA. Conclusion. Tibial eminence avulsion fracture has a similar risk associated with Bi-UKA to UKA-M. The risk is higher for smaller and less dense tibiae. To minimize risk, it is most important to avoid overstuffing the joint, followed by correctly positioning the medial implant, taking care not to narrow the bone island anteriorly. Cite this article: Bone Joint Res 2022;11(8):575–584


Bone & Joint Research
Vol. 12, Issue 8 | Pages 504 - 511
23 Aug 2023
Wang C Liu S Chang C

Aims. This study aimed to establish the optimal fixation methods for calcaneal tuberosity avulsion fractures with different fragment thicknesses in a porcine model. Methods. A total of 36 porcine calcanea were sawed to create simple avulsion fractures with three different fragment thicknesses (5, 10, and 15 mm). They were randomly fixed with either two suture anchors or one headless screw. Load-to-failure and cyclic loading tension tests were performed for the biomechanical analysis. Results. This biomechanical study predicts that headless screw fixation is a better option if fragment thickness is over 15 mm in terms of the comparable peak failure load to suture anchor fixation (headless screw: 432.55 N (SD 62.25); suture anchor: 446.58 N (SD 84.97)), and less fracture fragment displacement after cyclic loading (headless screw: 3.94 N (SD 1.76); suture anchor: 8.68 N (SD 1.84)). Given that the fragment thickness is less than 10 mm, suture anchor fixation is a safer option. Conclusion. Fracture fragment thickness helps in making the decision of either using headless screw or suture anchor fixation in treating calcaneal tuberosity avulsion fracture, based on the regression models of our study. Cite this article: Bone Joint Res 2023;12(8):504–511


Bone & Joint Open
Vol. 3, Issue 5 | Pages 415 - 422
17 May 2022
Hillier-Smith R Paton B

Aims. Avulsion of the proximal hamstring tendon origin can result in significant functional impairment, with surgical re-attachment of the tendons becoming an increasingly recognized treatment. The aim of this study was to assess the outcomes of surgical management of proximal hamstring tendon avulsions, and to compare the results between acute and chronic repairs, as well as between partial and complete injuries. Methods. PubMed, CINAHL, SPORTdiscuss, Cochrane Library, EMBASE, and Web of Science were searched. Studies were screened and quality assessed. Results. In all, 35 studies (1,530 surgically-repaired hamstrings) were included. Mean age at time of repair was 44.7 years (12 to 78). A total of 846 tears were acute, and 684 were chronic, with 520 tears being defined as partial, and 916 as complete. Overall, 92.6% of patients were satisfied with the outcome of their surgery. Mean Lower Extremity Functional Score was 74.7, and was significantly higher in the partial injury group. Mean postoperative hamstring strength was 87.0% of the uninjured limb, and was higher in the partial group. The return to sport (RTS) rate was 84.5%, averaging at a return of 6.5 months. RTS was quicker in the acute group. Re-rupture rate was 1.2% overall, and was lower in the acute group. Sciatic nerve dysfunction rate was 3.5% overall, and lower in the acute group (p < 0.05 in all cases). Conclusion. Surgical treatment results in high satisfaction rates, with good functional outcomes, restoration of muscle strength, and RTS. Partial injuries could expect a higher functional outcome and muscle strength return. Acute repairs result in a quicker RTS with a reduced rate of re-rupture and sciatic nerve dysfunction. Cite this article: Bone Jt Open 2022;3(5):415–422


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 27 - 27
17 Apr 2023
Nand R Sunderamoorthy D
Full Access

An isolated avulsion fracture of the peroneus longus tendon is seldom seen and potentially can go undiagnosed using basic imaging methods during an initial emergency visit. If not managed appropriately it can lead to chronic pain, a reduced range of motions and eventually affect mobility. This article brings to light the effectiveness of managing such injuries conservatively. A 55 year old postman presented to clinic with pain over the instep of his right foot for 2 months with no history of trauma. Clinically the pain was confined to the right first metatarsophalangeal joint with occasional radiation to the calf. X-ray films did not detect any obvious bony injury. MR imaging revealed an ununited avulsion fracture of the base of the 1st metatarsal. The patient was subsequently injected with a mix of steroid and local anesthetic injections at the painful nonunion site under fluoroscopic guidance. Post procedure there was no neurovascular deficit. The patient was reviewed at three months and his pain score and functional outcome improved significantly. Moreover following our intervention, the Manchester Oxford Foot Questionnaire reduced from 33 to 0. At the one year follow up he remained asymptomatic and was discharged. The peroneus longus tendon plays a role in eversion and planter flexion of foot along with providing stabilization to arches of foot. The pattern of injury to this tendon is based on two factors one is the mechanism of insult, if injured, and second is the variation in the insertion pattern of peroneus longus tendon itself. There is no gold standard treatments by which these injuries can be managed. If conservative management fails we must also consider surgery which involves percutaneous fixation, or excision of the non-healed fracture fragment and arthrodesis. To conclude isolated avulsion fractures of peroneus longus tendon are rare injuries and it is important to raise awareness of this injury and the diagnostic and management challenges faced. In this case conservative management was a success in treating this injury however it is important to take factors such as patient selection, patient autonomy and clinical judgement into account before making the final decision


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_16 | Pages 75 - 75
1 Dec 2021
Stoddart J Garner A Tuncer M Cobb J van Arkel R
Full Access

Abstract. Objectives. There is renewed interest in bi-unicondylar arthroplasty (Bi-UKA) for patients with medial and lateral tibiofemoral osteoarthritis, but a spared patellofemoral compartment and functional cruciate ligaments. The bone island between the two tibial components may be at risk of tibial eminence avulsion fracture, compromising function. This finite element analysis compared intraoperative tibial strains for Bi-UKA to isolated medial unicompartmental arthroplasty (UKA-M) to assess the risk of avulsion. Methods. A validated model of a large, high bone-quality tibia was prepared for both UKA-M and Bi-UKA. Load totalling 450N was distributed between the two ACL bundles, implant components and collateral ligaments based on experimental and intraoperative measurements with the knee extended and appropriately sized bearings used. 95th percentile maximum principal elastic strain was predicted in the proximal tibia. The effect of overcuts/positioning for the medial implant were studied; the magnitude of these variations was double the standard deviation associated with conventional technique. Results. For all simulations, strains were an order of magnitude lower than that associated with bone fracture. Highest strain occurred in the spine, under the anteromedial ACL attachment, adjacent to transverse overcut of the medial component. Consequently, Bi-UKA had little effect on strain: <10% increases were predicted when compared to UKA-M with equivalent medial cuts/positioning. However, surgical overcutting/positional variation that resulted in loss of anteromedial bone in the spine increased strain. The biggest increase was for lateral translation of the medial component: 44% and 42% for UKA-M and Bi-UKA, respectively. Conclusions. For a large tibia with high bone quality, Bi-UKA with a well-positioned lateral implant had no tangible effect on the risk of tibial eminence avulsion fracture compared to UKA-M. Malpositioning of the medial component that removes bone from the anterior spine could prove problematic for smaller tibiae. Declaration of Interest. (a) fully declare any financial or other potential conflict of interest


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 91 - 91
23 Feb 2023
Cecchi S Aujla R Edwards P Ebert J Annear P Ricciardo B D'Alessandro P
Full Access

Avulsion of the proximal hamstring tendon from the ischial tuberosity is an uncommon but significant injury. Recent literature has highlighted that functional results are superior with surgical repair over non-surgical treatment. Limited data exists regarding the optimal rehabilitation regime in post-operative patients. The aim of this study was to investigate the early interim patient outcomes following repair of proximal hamstring tendon avulsions between a traditionally conservative versus an accelerated rehabilitation regimen. In this prospective randomised controlled trial (RCT) 50 patients underwent proximal hamstring tendon avulsion repair, and were randomised to either a braced, partial weight-bearing (PWB) rehabilitation regime (CR = 25) or an accelerated, unbraced, immediate full weight-bearing (FWB) regime (AR group; n = 25). Patients were evaluated preoperatively and at 3 months after surgery, using the Lower Extremity Functional Scale (LEFS), Perth Hamstring Assessment Tool (PHAT), visual analog pain scale (VASP), Tegner score, and 12-item Short Survey Form (SF-12). Patients also filled in a diary questioning postoperative pain at rest from Day 2, until week 6 after surgery. Primary analysis was by per protocol and based on linear mixed models. Both groups, with respect to patient and characteristics were matched at baseline. Over three months, five complications were reported (AR = 3, CR = 2). At 3 months post-surgery, significant improvements (p<0.001) were observed in both groups for all outcomes except the SF-12 MCS (P = 0.623) and the Tegner (P = 0.119). There were no significant between-group differences from baseline to 3 months for any outcomes, except for the SF-12 PCS, which showed significant effects favouring the AR regime (effect size [ES], 0.76; 95% CI, 1.2-13.2; P = .02). Early outcomes in an accelerated rehabilitation regimen following surgical repair of proximal hamstring tendon avulsions, was comparable to a traditionally conservative rehabilitation pathway, and resulted in better physical health-related quality of life scores at 3 months post-surgery. Further long term follow up and functional assessment planned as part of this study


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 25 - 25
2 May 2024
Ajula R Mayne A Cecchi S Ebert J Edwards P Davies P Ricciardo B Annear P D'Alessandro P
Full Access

Proximal hamstring tendon avulsion from the ischial tuberosity is a significant injury, with surgical repair shown to have superior functional outcomes compared to non-surgical treatment. However, limited data exists regarding the optimal rehabilitation regime following surgical repair. The aim of this study was to investigate patient outcomes following repair of proximal hamstring tendon avulsions between a conservative (CR) versus an accelerated rehabilitation (AR) regimen. This prospective randomized controlled trial (RCT) randomised 50 patients undergoing proximal hamstring tendon repair to either a braced, partial weight-bearing rehabilitation regime (CR=25) or an accelerated, unbraced regime, that permitted full weight-bearing as tolerated (AR=25). Patients were evaluated pre-operatively and at 3 and 6 months post-surgery, via patient-reported outcome measures (PROMs) including the Lower Extremity Functional Scale (LEFS), Perth Hamstring Assessment Tool (PHAT) and 12-item Short Form Health Survey (SF-12). Primary analysis was per protocol and based on linear mixed models. Both groups were matched at baseline with respect to patient characteristics. All PROMs improved (p>0.05) and, while the AR group reported a significantly better Physical Component Score for the SF-12 at 3 months (p=0.022), there were no other group differences. Peak isometric hamstrings strength and peak isokinetic quadriceps and hamstrings torque symmetry were all comparable between groups (p>0.05). Three re-injuries have been observed (CR=2, AR=1). After proximal hamstring repair surgery, post-operative outcomes following an accelerated rehabilitation regimen demonstrate comparable outcomes to a traditionally conservative rehabilitation pathway, albeit demonstrating better early physical health-related quality of life scores, without an increased incidence of early re-injury


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 150 - 150
1 Jul 2020
Paul R Khan R Whelan DB
Full Access

Fibular head avulsion fractures represent a significant injury to the posterolateral corner of the knee. There is a high rate of concomitant injuries including rupture of the cruciate ligaments. Surgical fixation is indicated to restore stability, protect repaired or reconstructed cruciate ligaments and possibly decrease the likelihood of degenerative change. The current presentation describes a novel technique which provides secure fixation to the fibular head, restoring integrity of the posterolateral ligament complex and facilitating early motion. We also present a case series of our experience by a single surgeon at our tertiary referral center. Twenty patients underwent open reduction and internal fixation between 2006 and 2016 using a large fragment cannulated screw and soft tissue washer inserted obliquely from the proximal fibula to tibia. Fixation was augmented with suture repair of the lateral collateral ligament and biceps tendon. The orientation of the fracture was assessed based on preoperative imaging. Repair / reconstruction of concomitant injuries was performed during the same procedure. Early range of motion was initiated at 2 weeks postoperatively under physical therapy guidance. All patients returned for clinical and radiographic assessment (average 3.5 years). All fractures went on to bony union. There were no reoperations for recurrent instability. All patients regained functional range of motion with mean extension of 0.94 degrees and mean flexion of 121.4 degrees. Two patients underwent hardware removal. One patient developed a late local infection, which occurred greater than 5 years after surgery. Eleven patients underwent postoperative varus stress radiographs which demonstrated less than 1 mm difference between the operated and contralateral side. Fracture morphology typically demonstrated an oblique pattern in the coronal plane and a transverse pattern in the sagittal plane. This study represents a novel surgical technique for the repair of fibular head avulsion fractures with a large fragment cannulated screw placed obliquely from the fibula to tibia. Fixation is augmented with a soft tissue washer and suture repair. Our results suggest that this technique allows for early range of motion with maintenance of reduction, high rates of union, and excellent postoperative stability


The Journal of Bone & Joint Surgery British Volume
Vol. 51-B, Issue 1 | Pages 118 - 122
1 Feb 1969
Protheroe K

1. Five cases of avulsion fracture of the calcaneus are reported. 2. The "beak" fracture of the calcaneus is thought to be a variant of the avulsion fracture and not a separate entity. 3. The variable attachment of the calcaneal tendon to the calcaneus is described, and its relationship to the different forms of avulsion fractures discussed. 4. Operative reduction and fixation are appropriate for young and active patients in order to restore full heel-cord function. 5. Attention is drawn to the risk of pressure necrosis of skin overlying a displaced fragment. Early operative correction may be required to prevent skin damage


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 395 - 395
1 Dec 2013
Lee J Yoon J Lee J
Full Access

To investigate the effectiveness of avulsion fracture of tibial insertion of posterior cruciate ligament using the safe postero-medial approach through analyzing the clinical and radiographic outcomes. We treated 14 cases of acute PCL tibial avulsion fracture with “safe postero-medial approach”. The PCL and avulsion bony fragment was fixed with 1 cannuated screw and washer. The patients were assessed clinically and radiographically at 3 months, 6 months, and 12 months. Clinical examination for each visit included assessment of the knee range of motion, using goniometer and the posterior drawer test. The patients were evaluated according to the Lysholm and Tegner rating scales. Patients were followed-up for 12 to 16 months. X-ray showed that satisfactory reducdtion and bony healing was achieved in all cases. There was no neurovascular complication. All patients had negative posterior drawer tests. Excellent outcomes were reported by all patients with the Lysholm score system. And there was no signicant difference between the Tegner scores before injury and last follow-up. Surgical treatment of acute tibial avulsion fracture of the PCL with this approach can restore the stability and fuction of the joint safely in most patients without neurovascular complication. Therefore “safe postero-medial approach” may be suitable for the treatment of isolated tibial avulsion fracture of the PCL


The Bone & Joint Journal
Vol. 97-B, Issue 11 | Pages 1488 - 1492
1 Nov 2015
Tansey RJ Benjamin-Laing H Jassim S Liekens K Shankar A Haddad FS

Hip and groin injuries are common in athletes who take part in high level sports. Adductor muscle tendon injuries represent a small but important number of these injuries. Avulsion of the tendons attached to the symphysis pubis has previously been described: these can be managed both operatively and non-operatively. We describe an uncommon variant of this injury, namely complete avulsion of the adductor sleeve complex: this includes adductor longus, pectineus and rectus abdominis. We go on to describe a surgical technique which promotes a full return to the pre-injury level of sporting activity. Over a period of ten years, 15 high-level athletes with an MRI-confirmed acute adductor complex avulsion injury (six to 34 days old) underwent surgical repair. The operative procedure consisted of anatomical re-attachment of the avulsed tissues in each case and mesh reinforcement of the posterior inguinal wall in seven patients. All underwent a standardised rehabilitation programme, which was then individualised to be sport-specific. One patient developed a superficial wound infection, which was successfully treated with antibiotics. Of the 15 patients, four complained of transient local numbness which resolved in all cases. All patients (including seven elite athletes) returned to their previous level of participation in sport. Cite this article: Bone Joint J 2015;97-B:1488–92


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_I | Pages 19 - 19
1 Jan 2003
Jennings A Bollen S
Full Access

This study set out to determine the incidence of avulsion of the posterior horn of the lateral meniscus in isolated Anterior cruciate ligament injuries. Anterior cruciate injuries are often associated with meniscal injuries and a number of different patterns of injuries are described. Although avulsion of the posterior horn of the lateral meniscus has been reported in combined ACL/MCL injuries this has not been reported in isolated ACL injuries. We examined 25 consecutive patients who had ACL ruptures and recorded the presence or absence of an avulsed posterior horn of the lateral meniscus. The mechanism of injury was also recorded. We found 6 patients (24%) with avulsion of the posterior horn of the lateral meniscus from its tibial attachment. All these patients had an external rotation injury rather than a valgus type injury. Avulsion of the posterior horn of the lateral meniscus is a relatively common finding in ACL injury. If this injury occurs the normal load sharing function of the meniscus may not be present and this may be part of the explanation for the development of degenerative change in the ACL injured knee


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_11 | Pages 55 - 55
1 Nov 2022
Jimulia D Saad A Malik A
Full Access

Abstract. Background. Anterior cruciate ligament (ACL) injuries with coinciding posterolateral tibial plateau (PLTP) depression fractures are rare. According to the most up to date literature, addressing the PLTP is crucial in preventing failure of the ACL. However, the surgical management of these injuries pose a great challenge to orthopaedic surgeons, given the anatomical location of the depressed PTP fragment. We report a case of a 17-year-old patient presenting to our department with this injury and describe a novel fixation method, that has not been described in the literature. Surgical Technique. A standard 2-portal arthroscopy is used to visualise the fractures. The PLTP is addressed first. With the combined use of arthroscopy and fluoroscopy, a guide pin is triangulated from the anteromedial aspect of the tibia, towards the depressed plateau fragment. Once the guide pin is approximately 1cm from the centre of the fragment, it is over-drilled with a cannulated drill, and simultaneously bluntly punched up to its original anatomical location. Bone graft is then used to fill the void, supported by two subchondral screws. Both fluoroscopy and arthroscopy are used to confirm adequacy of fixation. Finally, the tibial spine avulsion fracture is repaired arthroscopically using the standard suture bridging technique. Conclusion. We describe a novel, one-stage, minimally invasive approach that addresses both the ACL injury and PLTP fracture. We highlight the advantages of utilising this approach and functional outcomes


The Journal of Bone & Joint Surgery British Volume
Vol. 51-B, Issue 3 | Pages 494 - 497
1 Aug 1969
Lowy M

1. The literature on fractures of the postero-superior aspect of the calcaneus is reviewed. 2. The mechanical distinction between "beak" fractures and avulsion fractures is questioned, and the dangers of a purely radiological diagnosis are stressed. 3. When a complete avulsion is suspected on clinical grounds, open reduction should be done


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_13 | Pages 44 - 44
1 Oct 2018
Incavo SJ Brown L Park K Lambert B Bernstein D
Full Access

Introduction. Hip abductor tendon tears have been referred to as “rotator cuff tears of the hip,” and are a recognized etiology for persistent, often progressive, lateral hip pain, weakness, and limp. Multiple repair techniques and salvage procedures for abductor tendon tears have been reported in the literature; however, re-tear remains a frequent complication following surgical repair. This study compares the short-term outcomes of open abductor tendon repairs with decortication and suture fixation (DSF) compared to a modified technique repair into a bone trough (BT), to determine best surgical results for large abductor tendon avulsions. Additionally, surgical treatment of small tears versus large tears was examined. Methods. The outcomes of 37 consecutive hip abductor tendon repairs treated between January 2009 and December 2017 were retrospectively reviewed. Large tears were defined as detachment of 33–100% of the gluteus medius insertion. There were 15 DSF and 10 BT cases. Postoperative pain, ability to perform single leg stance, hip abduction, and Trendelenburg lurch, were examined. Small tears (12 cases) were defined as having no gluteus medius avulsion from the trochanteric insertion and were comprised of longitudinal tears (repaired side-by-side) and isolated gluteus minimus tears (repaired by tenodesis to the overlying gluteus medius). Standard statistical analyses were utilized. Type I error for all analyses was set at α=0.05. Results. When comparing large tear repair outcomes, repairs into a BT had superior outcomes to repairs with DSF: 0 (BT) versus 6 (DSF, 40%) failure rate (p<0.05), and greater reductions in pain at one-year post surgery (Δ VAS: BT, −5.70±0.97 | DSF: −2.73±0.69; p<0.01), ability to perform a single leg stance and hip abduction (90% and 100% vs 47% and 73%) (p<0.05). Clinical strength ratings were higher for repairs into a BT, but this did not reach statistical significance. When comparing large to small tear repair outcomes, small tears were found to have lower VAS pain scores and higher clinical strength ratings during both the pre-op and 1-year post-op time points (p<0.05). A higher percentage of those with small tears were able to perform a single leg stance and hip abduction (100%) compared to those with large tears (64% and 78% respectively) (p<0.05). A significantly higher frequency of residual lurch was also observed for those with large tears; 56% compared to small tears at 0%. Conclusions. Utilizing a BT repair significantly improved surgical results for large abductor tendon avulsions. Level of evidence: Therapeutic level IV case series


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_III | Pages 367 - 367
1 Jul 2010
Lang DM Monga P
Full Access

Aim: To review the outcomes for avulsion fractures of the tibial spine in children managed by arthroscopic internal fixation using a canulated screw. Materials & Methods: A retrospective review was performed of 8 tibial spine avulsion fractures in children managed operatively by arthroscopic canulated screw fixation over a 4 year period. All fractures were graded grade III or IV (Meyer and McKeevers) in severity. Notes and radiographs were reviewed and Lysholm scores were obtained. The average age of our patients was 10.6 years and the average duration of follow up was 23.6 months (Range: 3–52 months). The average Lysholm score achieved was 88.9 (median 94.5, range 61–100) with the score demonstrably improving after the first year from injury. Bony healing was seen in all cases. One patient needed manipulation under anaesthesia to realize full movement. Conclusions: On the basis of these results, we recommend arthroscopic canulated screw fixation as the treatment of choice for tibial spine avulsions. It takes over a year, however, to achieve optimal results. This series represents the largest collection of these uncommon injuries hitherto reported from the UK


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 8 - 8
1 Mar 2009
Lakshmanan P Sharma A Peehal J David H
Full Access

Introduction: Avulsion fractures of the anterior tibial spine are not so common. The best form of treatment for displaced fractures is still debatable. Aims: We aimed to analyze the results of different forms of internal fixation for avulsion fractures of the anterior tibial spine. Material and Methods: Twenty-five patients with avulsion fractures of the anterior tibial spine had open reduction and internal fixation with different implants (AO screw, Herbert screw, stainless steel wire loop and absorbable stitch) and techniques. The mean follow up period was 3.66 years. They were evaluated clinically and radiologically, using KT 1000 arthrometer for ACL laxity and goniometer for range of movements. The outcome was measured using Lysholm Knee Score. Results: Significant residual anterior laxity despite adequate fracture union was a common finding. Maximum ACL laxity was seen in adults in whom absorbable stitches had been used and they had a corresponding lower Lysholm score. Significant migration of the Herbert screws was noted in two of five patients in which it was used. Five of the eight patients with higher Lysholm score had AO screw fixation. Three patients with steel wire loop for stabilization of the fracture also had better results comparatively. Three individuals who had their knee immobilised in 25°–50° of flexion developed fixed flexion deformities, which took 12–18 months to recover. Conclusions: The use of absorbable stitches as the primary method of fixation for avulsion fractures of the tibial spine should be avoided in adults. Herbert screw in this situation has a tendency to migrate. AO screws and non-absorbable loop yields better functional outcome. Immobilization of the knee in excessive flexion leads to prolonged fixed flexion deformity. Early range of movements can be achieved by replacing cast with a brace allowing flexion up to 90 degrees


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 175 - 175
1 Sep 2012
Foote CJ Forough F Maizlin Z Ayeni O
Full Access

Purpose. Rectus femoris avulsion (RFA) injuries in paediatric patients are currently managed conservatively. However, the proximal attachment of the rectus femoris muscle lies in a critical zone in the hip joint with attachments to the anterior hip capsule and anterior inferior iliac spine. Violent avulsions therefore could cause damage to the adjacent acetabular labrum and articular cartilage initiating a process leading to early degenerative changes in the hip. To date, the association between rectus avulsions and labral tears has not been studied. Method. The complete medical records of patients who were presented to McMaster University Medical Center with rectus femoris avulsions between 1983 and 2008 who were between the ages of 2 and 18 were identified. Patients were included if they had documented plain radiographs and magnetic resonance arthrography images of their hip. MRIs were reviewed by an independent musculoskeletal radiologist blinded from the history of the patients. Results. 16 patients were identified in the database with rectus femoris avulsions diagnosed on plain radiograph and 7 were included in the study with documented MRIs. The average age of patients was 13 (Range 7–16). All injuries occurred during sports activity with 43% occurred during running, 29% with kicking during soccer and during skating acceleration while playing hockey. One patient had a concurrent sartorius avulsion. All patients with rectus femoris avulsions had labral tears identified on MRI in the zone adjacent to rectus insertion. All patients were treated conservatively. Clinical records suggested 72% of patients were still limping and 86% were experiencing residual pain at last follow-up. Conclusion. Patients with rectus femoris avulsions may be at risk for concurrent traumatic labral tears. These patients should be assessed for labral pathology including a clinical examination and MRI arthrography. Level of Evidence: Level IV


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 2 | Pages 242 - 244
1 Mar 1995
Nakhostine M Perko M Cross M

We report four patients with a mean age of 17 years (14 to 22) with external rotation injuries of the knee in slight flexion. Radiographs showed a small fragment in the area of the lateral femoral condyle. At operation, the fragment, consisting of the femoral insertion of the popliteus, was anatomically reduced and fixed. At a mean follow-up of 35 months all the knees had an excellent function score. An isolated lesion of the popliteus often presents as a tendon avulsion whereas major damage to the posterolateral corner of the knee involves combined ligamentous injuries. In patients with an acute haemarthrosis and lateral pain in a stable knee, the diagnosis of isolated avulsion of the popliteus tendon should be suspected. Arthroscopy with special attention to the lateral gutter is indicated. We advise anatomical reduction and fixation of the fragment to prevent possible long-term effects on other posterolateral structures