header advert
Results 1 - 20 of 548
Results per page:
Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 169 - 169
1 Sep 2012
Bartlett G Wilson M Whitehouse S Hubble M Gie G Timperley J Howell J
Full Access

We present 346 consecutive revision procedures for aseptic loosening with acetabular impaction bone grafting (AIBG) and a cemented polyethylene cup. Defects were contained with mesh alone. Mean follow up of 6.6 years, range 8 days-13 years. The Oxford Hip (OHS) and Harris Hip (HHS) scores were collected prospectively. Radiological definition of cup failure was either > 5mm displacement, or > 5° rotation. Cox regression analysis was performed on ten separate patient and surgical factors to determine their significance on survivorship. Kaplan Meier survivorship at 10 years (42 cases remaining at risk) for aseptic loosening was 87% (95% confidence Interval (CI): 81.6 to 92.2) and 85.6% (95% CI: 80.3 to 90.9) for all revisions. These results are comparable to other reported series utilising AIBG. However, there were 88 cases (25%) that exceeded the radiological migration parameters, but their functional scores were not significantly different to the non-migrators: OHS p=0.273, HHS p=0.16. The latest post-operative mean OHS was 33 (SD 10.66). Female gender (p=0.039), increasing graft thickness (p=0.006) and the use of mesh (p=0.037) were significant risk factors for revision, but differing techniques in graft preparation, including artificial graft expanders (p=0.73), had no significant effect when analysed using Cox regression


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 28 - 28
10 Feb 2023
Faveere A Milne L Holder C Graves S
Full Access

Increasing femoral offset in total hip replacement (THR) has several benefits including improved hip abductor strength and enhanced range of motion. Biomechanical studies have suggested that this may negatively impact on stem stability. However, it is unclear whether this has a clinical impact. Using data from the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR), the aim of this study was to determine the impact of stem offset and stem size for the three most common cementless THR prostheses revised for aseptic loosening. The study period was September 1999 to December 2020. The study population included all primary procedures for osteoarthritis with a cementless THR using the Corail, Quadra-H and Polarstem. Procedures were divided into small and large stem sizes and by standard and high stem offset for each stem system. Hazard ratios (HR) from Cox proportional hazards models, adjusting for age and gender, were performed to compare revision for aseptic loosening for offset and stem size for each of the three femoral stems. There were 55,194 Corail stems, 13,642 Quadra-H stem, and 13,736 Polarstem prostheses included in this study. For the Corail stem, offset had an impact only when small stems were used (sizes 8-11). Revision for aseptic loosening was increased for the high offset stem (HR=1.90;95% CI 1.53–2.37;p<0.001). There was also a higher revision risk for aseptic loosening for high offset small size Quadra-H stems (sizes 0-3). Similar to the Corail stem, offset did not impact on the revision risk for larger stems (Corail sizes 12-20, Quadra-H sizes 4-7). The Polarstem did not show any difference in aseptic loosening revision risk when high and standard offset stems were compared, and this was irrespective of stem size. High offset may be associated with increased revision for aseptic loosening, but this is both stem size and prosthesis specific


The Bone & Joint Journal
Vol. 95-B, Issue 8 | Pages 1022 - 1026
1 Aug 2013
O’Neill SC Queally JM Devitt BM Doran PP O’Byrne JM

Peri-prosthetic osteolysis and subsequent aseptic loosening is the most common reason for revising total hip replacements. Wear particles originating from the prosthetic components interact with multiple cell types in the peri-prosthetic region resulting in an inflammatory process that ultimately leads to peri-prosthetic bone loss. These cells include macrophages, osteoclasts, osteoblasts and fibroblasts. The majority of research in peri-prosthetic osteolysis has concentrated on the role played by osteoclasts and macrophages. The purpose of this review is to assess the role of the osteoblast in peri-prosthetic osteolysis.

In peri-prosthetic osteolysis, wear particles may affect osteoblasts and contribute to the osteolytic process by two mechanisms. First, particles and metallic ions have been shown to inhibit the osteoblast in terms of its ability to secrete mineralised bone matrix, by reducing calcium deposition, alkaline phosphatase activity and its ability to proliferate. Secondly, particles and metallic ions have been shown to stimulate osteoblasts to produce pro inflammatory mediators in vitro. In vivo, these mediators have the potential to attract pro-inflammatory cells to the peri-prosthetic area and stimulate osteoclasts to absorb bone. Further research is needed to fully define the role of the osteoblast in peri-prosthetic osteolysis and to explore its potential role as a therapeutic target in this condition.

Cite this article: Bone Joint J 2013;95-B:1021–5.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 52 - 52
23 Feb 2023
Full Access

THA in patients with acetabular bone defects is associated with a high risk of dislocation. Dual mobility (DM) cups are known to prevent and treat chronic instability. The aim of this study was to evaluate the dislocation rate and survival of jumbo DM cups. This was a retrospective, continuous, multicenter study of all the cases of jumbo DM cup implantation between 2010 and 2017 in patients with acetabular bone loss (Paprosky 2A: 46%, 2B: 32%, 2C: 15% and 3A: 6%). The indications for implantation were revisions for aseptic loosening of the cup (n=45), aseptic loosening of the femoral stem (n=3), bipolar loosening (n=11), septic loosening (n=10), periprosthetic fracture (n=5), chronic dislocation (n=4), intraprosthetic dislocation (n=2), cup impingement (n=1), primary posttraumatic arthroplasty (n=8), and acetabular dysplasia (n=4). The jumbo cups used were COPTOS TH (SERF), which combines press-fit fixation with supplemental fixation (acetabular hook, two superior flanges with one to four screws, two acetabular pegs). A bone graft was added in 74 cases (80%). The clinical assessment consisted of the Harris hip score. The primary endpoint was surgical revision for aseptic acetabular loosening or the occurrence of a dislocation episode. In all, 93 patients were reviewed at a mean follow-up of 5.3 ± 2.3 years [0, 10]. As of the last follow-up, the acetabular cup had been changed in five cases: three due to aseptic loosening (3.2%) and two due to infection (2.1%). The survivorship free of aseptic loosening was 96.8%. Three patients (3%) suffered a dislocation. At the last follow-up visit, the mean HSS scores were 72.15, (p < 0.05). Use of a jumbo DM cup in cases of acetabular bone defects leads to satisfactory medium-term results with low dislocation and loosening rates


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 112 - 112
23 Feb 2023
Deng Y Zhang D Smith P Li R
Full Access

Hip and knee arthroplasty (HKA) are two of the most successful orthopaedic procedures. However, one major complication necessitating revision surgery is osteolysis causing aseptic loosening of the prosthesis. JAK-STAT has been demonstrated to influence bone metabolism and can be regulated by microRNA (miRNA). Adult patients with osteolysis or aseptic loosening undergoing revision HKA were recruited. Age and gender matched patients undergoing primary hip or knee arthroplasty were our controls. Samples of bone, tissue and blood were collected and RNA isolation was performed. The best quality samples were used for RNA-sequencing. Data analysis was performed using RStudio and Galaxy to identify differentially expressed genes. Western blotting of IL6 was used to confirm protein expression. Five circulating miRNA were identified which had 10 differentially expressed genes in bone and 11 differentially expressed genes in tissue related to the JAK-STAT pathway. IL6 in bone and EpoR in bone were highly significant and IL6 in tissue, MPL in bone, SOCS3 in tissue, JAK3 in bone and SPRED1 in bone were borderline significant. Western blot results demonstrated up-expression of IL6 in bone tissue of revision patients. Periprosthetic osteolysis and aseptic loosening can be attributed to miRNA regulation of the JAK-STAT pathway in osteoblasts and osteoclasts, leading to increased bone resorption. These findings can be used for further experiments to determine utility in the clinical setting for identifying diagnostic markers or therapeutic targets


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_8 | Pages 1 - 1
10 May 2024
Scherf E Willis J Frampton C Hooper G
Full Access

Introduction. The mobile-bearing (MB) total knee arthroplasty (TKA) design was introduced with the aim of reducing polyethylene wear and component loosening seen in the fixed-bearing (FB) design. A recent joint registry study has revealed increased risk for all-cause revision, but not revision for infection, in MB-TKA. We used the New Zealand Joint Registry (NZJR) to compare all-cause revision rates, and revision rates for aseptic loosening of MB-TKA compared with fixed bearing (FB) TKA. Methods. All patients who underwent a primary TKA registered in the NZJR between the 1st January 1999 to 31st December 2021 were identified. Analysis compared MB to FB designs, with sub analysis of implants from a single company. We identified 135,707 primary TKAs, with 104,074 (76.7%) FB-TKAs and 31,633 (23.3%) MB-TKAs recorded. We examined all-cause revision rates, reasons for revision and performed survival analyses. Results. For all-comers, MB-TKA had an all-cause revision rate of 0.43/100-component-years (OCY) compared with 0.42/OCY for FB-TKA (p=0.09). The all-cause revision rate was higher for those age < 65 years (MB TKA 0.60/OCY vs. FB-TKA 0.59/OCY) compared to those > 65 years at time of primary TKA (MB-TKA 0.29/OCY vs. FB-TKA 0.32/OCY), however there was no statistically significant difference between implant design in either age group (p=0.16 and p=0.64; respectively). Similarly, there was no difference in revision rates for aseptic loosening between implant designs. Kaplan-Meier survival analysis demonstrates no statistically significant difference in revision-free survival of implants, with both MB-TKA and FB-TKA demonstrating ∼93% revision free survival at 23 years. Conclusions. Both FB- and MB-TKA demonstrated excellent survivorship, with no significant difference in all-cause revision rates or revision for aseptic loosening between implant designs


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_10 | Pages 37 - 37
1 Oct 2022
Lutro O Mo S Leta TH Fenstad AM Tjørhom MB Bruun T Hallan G Furnes O Dale H
Full Access

Aim. In recent years, many studies on revision for infection after arthroplasty have been published. In national arthroplasty registers, revision for infection is defined as surgical debridement, with or without removal or exchange of the entire or parts of the prosthesis due to deep infection, and should be reported to the register immediately after surgery. The diagnosis of infection is made at the surgeon's discretion, based on pre- and perioperative assessment and evaluation, and is not to be corrected to the register based on peroperative bacterial cultures. Due to this lack of validation, the rate of revision for infection will only be an approximation of the true rate of periprosthetic joint infection (PJI). Our aim was to validate the reporting of infection after total hip arthroplasty, and to assess if revisions for infection actually represented true PJI. Methods. We investigated the reported revisions for infection and aseptic loosening after total hip arthroplasty from 12 hospitals, representing one region of the country, reported during the period 2010–2020. The electronic patient charts were investigated for information on surgical treatment, use of antibiotics, biochemistry and microbiology findings. PJI was defined as growth of at least two phenotypically identical microbes in perioperative tissue samples. Sensitivity, specificity, positive predictive value, negative predictive value and accuracy were calculated. Results. 145 revisions for infection and 137 revisions for aseptic loosening were reported. Of the reported infections, there were 141/145 true positives and 4/145 false positives. Of the reported aseptic loosenings, there were 126/137 true negatives and 11/137 false negatives. This gives a positive predictive value of 0.97, negative predictive value of 0.92, sensitivity of 0.93, specificity of 0.97 and accuracy of 0.95. Interpretation. We found the reporting revision for infection after total hip arthroplasty to the national register accurate. There was high correlation between reported revision for infection and PJI. Studies on revision for infection from arthroplasty registers may therefore be considered as reliable as studies of true PJI


Instability and aseptic loosening are the two main complications after revision total hip arthroplasty (rTHA). Dual-mobility (DM) cups were shown to counteract implant instability during rTHA. To our knowledge, no study evaluated the 10-year outcomes of rTHA using DM cups, cemented into a metal reinforcement ring, in cases of severe acetabular bone loss. We hypothesized that using a DM cup cemented into a metal ring is a reliable technique for rTHA at 10 years, with few revisions for acetabular loosening and/or instability. This is a retrospective study of 77 rTHA cases with severe acetabular bone loss (Paprosky ≥ 2C) treated exclusively with a DM cup (NOVAE STICK; SERF, DÉCINES-CHARPIEU, FRANCE) cemented into a cage (Kerboull cross, Burch-Schneider, or ARM rings). Clinical scores and radiological assessments were performed preoperatively and at the last follow-up. The main endpoints were revision surgery for aseptic loosening or recurring dislocation. With a mean follow-up of 10.7 years [2.1-16.2], 3 patients were reoperated because of aseptic acetabular loosening (3.9%) at 9.6 years [7-12]. Seven patients (9.45%) dislocated their hip implant, only 1 suffered from chronic instability (1.3%). Cup survivorship was 96.1% at 10 years. No sign of progressive radiolucent lines were found and bone graft integration was satisfactory for 91% of the patients. The use of a DM cup cemented into a metal ring during rTHA with complex acetabular bone loss was associated with low revision rates for either acetabular loosening or chronic instability at 10 years. That's why we also recommend DM cup for all high risk of dislocation situations


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_14 | Pages 5 - 5
23 Jul 2024
Mohammed F Jones S Mansoor Z Mehta S Rathore S Azam A
Full Access

Paget's disease of bone (PDB) is characterised by increased bone resorption and development of an erratic bone structure that is highly fragile and susceptible to fracture. In addition, altered joint biomechanics lead to arthritis, more often in the hip and pelvis, resulting in disability and a Total hip Arthroplasty (THA) may be required. THA in PDB is associated with more complications compared to normal population. There is no consensus on the type of arthroplasty that performs better in people with PDB. To our knowledge, there is no meta-analysis in literature on this rare problem. We undertook a systematic review and meta-analysis to compare the effectiveness of cemented versus cementless THA in patients with PDB. PRISMA guidelines were followed. Search strings were generated based on Boolean operators for identification of the reference articles. 31 studies were included overall. Revision rate was lower in the cementless group compared to the cemented group (chi square=4.36, p=0.04), aseptic loosening was lesser in the cementless group compared to the cemented group (chi square=4.13, p=0.04). The type of the arthroplasty did not affect the infection rate (chi square=2.51, p=0.11), pre and post op Harris Hip Score showed statistically significant difference, but there was no difference between types of arthroplasty. We conclude that THA with uncemented components is better and provided lower revision and aseptic loosening when compared to cemented groups in patients with PDB


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_15 | Pages 85 - 85
7 Nov 2023
Arakkal A Daoub M Nortje M Hilton T Le Roux J Held M
Full Access

The aim of this retrospective cohort study was to investigate the reasons for total knee arthroplasty (TKA) revisions at a tertiary hospital over a four-year period. The study aimed to identify the primary causes of TKA revisions and shed light on the implications for patient care and outcomes. The study included 31 patients who underwent revisions after primary knee arthroplasty between January 2017 and December 2020. A retrospective approach was employed, utilizing medical records and radiological findings to identify the reasons for TKA revisions. The study excluded oncology patients to focus on non-oncologic indications for revision surgeries. Patient demographics, including age and gender, were recorded. Data analysis involved categorizing the reasons for revision based on clinical assessments and radiological evidence. Among the 31 patients included in the study, 9 were males and 22 were females. The age of the patients ranged from 43 to 81, with a median age of 65 and an interquartile range of 18.5. The primary reasons for TKA revisions were identified as aseptic loosening (10 cases) and prosthetic joint infection (PJI) (13 cases). Additional reasons included revision from surgitech hemicap (1 case), patella osteoarthritis (1 case), stiffness (2 cases), patella maltracking (2 cases), periprosthetic fracture (1 case), and patella resurfacing (1 case). The findings of this retrospective cohort study highlight aseptic loosening and PJI as the leading causes of TKA revisions in the examined patient population. These results emphasize the importance of optimizing surgical techniques, implant selection, and infection control measures to reduce the incidence of TKA revisions. Future research efforts should focus on preventive strategies to enhance patient outcomes and mitigate the need for revision surgeries in TKA procedures


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 3 - 3
23 Feb 2023
Holzer L Finsterwald M Sobhi S Yates P
Full Access

This study aimed to analyze the effect of two different techniques of cement application: cement on bone surface (CoB) versus cement on bone surface and implant surface (CoBaI) on the short-term effect of radiolucent lines (RLL) in primary fully cemented total knee arthroplasties (TKA) with patella resurfacing. 379 fully cemented TKAs (318 patients) were included in this monocentric study. Preoperative and postoperative at week 4 and 12 month after surgery all patients had a clinical and radiological examination and were administered the Oxford Knee Score (OKS). Cement was applied in two different ways among the two study groups: cement on bone surface (CoB group) or cement on bone surface and implant surface (CoBaI group). The evaluation of the presence of RLL or osteolysis was done as previously described using the updated Knee Society Radiographic Evaluation System. The mean OKS and range of motion improved significantly in both groups at the 4-week and 12-month follow-up, with no significant difference between the groups (CoB vs. CoBaI). RLL were present in 4.7% in the whole study population and were significantly higher in the CoBaI group (10.5%) at the 4-week follow-up. At the 12-month follow-up RLL were seen in 29.8% of the TKAs in the CoBaI group, whereas the incidence was lower in the CoB group (24.0% (n.s.)). There were two revisions in each group. None of these due to aseptic loosening. Our study indicated that the application of bone cement on bone surface only might be more beneficial than onto the bone surface and onto the implant surface as well in respect to the short-term presence of RLL in fully cemented primary TKA. The long-term results will be of interest, especially in respect to aseptic loosening and might guide future directions of bone cement applications in TKA


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 4 - 4
10 Feb 2023
Sundaram A Hockley E Hardy T Carey Smith R
Full Access

Rates of prosthetic joint infection in megaprostheses are high. The application of silver ion coating to implants serves as a deterrent to infection and biofilm formation. A retrospective review was performed of all silver-coated MUTARS endoprosthetic reconstructions (SC-EPR) by a single Orthopaedic Oncology Surgeon. We examined the rate of component revision due to infection and the rate of infection successfully treated with antibiotic therapy. We reviewed overall revision rates, sub-categorised into the Henderson groupings for endoprosthesis modes of failure (Type 1 soft tissue failure, Type 2 aseptic loosening, Type 3 Structural failure, Type 4 Infection, Type 5 tumour progression). 283 silver-coated MUTARS endoprosthetic reconstructions were performed for 229 patients from October 2012 to July 2022. The average age at time of surgery was 58.9 years and 53% of our cohort were males. 154 (71.3%) patients underwent SC-EPR for oncological reconstruction and 32 (14.8%) for reconstruction for bone loss following prosthetic joint infection(s). Proximal femur SC-EPR (82) and distal femur (90) were the most common procedures. This cohort had an overall revision rate of 21.2% (60/283 cases). Component revisions were most commonly due to Type 4 infection (19 cases), Type 2 aseptic loosening/culture negative disease (15 cases), and Type 1 dislocation/soft tissue (12 cases). Component revision rate for infection was 6.7% (19 cases). 15 underwent exchange of implants and 4 underwent transfemoral amputation due to recalcitrant infection and failure of soft tissue coverage. This equates to a limb salvage rate of 98.3%. The most common causative organisms remain staphylococcus species (47%) and polymicrobial infections (40%). We expand on the existing literature advocating for the use of silver-coated endoprosthetic reconstructions. We provide insights from the vast experience of a single surgeon when addressing patients with oncological and bone loss-related complex reconstruction problems


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 42 - 42
1 Dec 2022
Fransen B Howard L MacDonell T Bengoa F Garbuz D Sheridan G Neufeld M
Full Access

Increased femoral head size reduces the rate of dislocation after total hip arthroplasty (THA). With the introduction of highly crosslinked polyethylene (HXLPE) liners in THA there has been a trend towards using larger size femoral heads in relatively smaller cup sizes, theoretically increasing the risk of liner fracture, wear, or aseptic loosening. Short to medium follow-up studies have not demonstrated a negative effect of using thinner HXLPE liners. However, there is concern that these thinner liners may prematurely fail in the long-term, especially in those with thinner liners. The aim of this study was to evaluate the long-term survival and revision rates of HXLPE liners in primary THA, as well as the effect of liner thickness on these outcomes. We hypothesized that there would be no significant differences between the different liner thicknesses. We performed a retrospective database analysis from a single center of all primary total hip replacements using HXLPE liners from 2010 and earlier, including all femoral head sizes. All procedures were performed by fellowship trained arthroplasty surgeons. Patient characteristics, implant details including liner thickness, death, and revisions (all causes) were recorded. Patients were grouped for analysis for each millimeter of PE thickness (e.g. 4.0-4.9mm, 5.0-5.9mm). Kaplan-Meier survival estimates were estimated with all-cause and aseptic revisions as the endpoints. A total of 2354 patients (2584 hips) were included (mean age 64.3 years, min-max 19-96). Mean BMI was 29.0 and 47.6% was female. Mean follow-up was 13.2 years (range 11.0-18.8). Liner thickness varied from 4.9 to 12.7 mm. Seven patients had a liner thickness <5.0mm and 859 had a liner thickness of <6.0mm. Head sizes were 28mm (n=85, 3.3%), 32mm (n=1214, 47.0%), 36mm (n=1176, 45.5%), and 40mm (n=109, 4.2%), and 98.4% were metal heads. There were 101 revisions, and in 78 of these cases the liner was revised. Reason for revision was instability/dislocation (n=34), pseudotumor/aseptic lymphocyte-dominant vasculitis associated lesion (n=18), fracture (n=17), early loosening (n=11), infection (n=7), aseptic loosening (n=4), and other (n=10). When grouped by liner thickness, there were no significant differences between the groups when looking at all-cause revision (p=0.112) or aseptic revision (p=0.116). In our cohort, there were no significant differences in all-cause or aseptic revisions between any of the liner thickness groups at long-term follow-up. Our results indicate that using thinner HXPE liners to maximize femoral head size in THA does not lead to increased complications or liner failures at medium to long term follow-up. As such, orthopedic surgeons can consider the use of larger heads at the cost of liner thickness a safe practice to reduce the risk of dislocation after THA when using HXLPE liners


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_17 | Pages 60 - 60
24 Nov 2023
Simon S Frank BJ Hartmann SG Mitterer JA Sujeesh S Huber S Hofstaetter JG
Full Access

Aims. The aim of this study was to assess the incidence the microbiological spectrum and clinical outcome of hip and knee revision arthroplasties with unexpected-positive-intraoperative-cultures (UPIC) at a single center with minimum follow up of 2 years. Methods. We retrospectively analyzed our prospectively maintained institutional arthroplasty registry. Between 2011 and 2020 we performed presumably aseptic rTHA (n=939) and rTKA (n= 1,058). Clinical outcome, re-revision rates and causes as well as the microbiological spectrum were evaluated. Results. In total, 219/939 (23.3%) rTHA and 114/ 1,058 (10.8%) rTKA had a UPIC (p<0.001). Single positive intraoperative cultures were found in 173/219 (78.9%) in rTHA and 99/114 (86.8%) in rTKA, whereas 46/219 (21.0%) rTHA and 15/114 (13.2%) rTKA had positive results in ≥2 intraoperative cultures. A total of 390 microorganisms were found among the 333 cases. Staphylococcus epidermidis 30.9%, CoNS (21.9%), Cutibacterium acnes 21.1%, and Bacillus spp. 7.3% were the most common microorganisms. Overall, detected microorganisms showed high sensitivity to daptomycin (96.6%), vancomycin (97.3%) and linezolid (98.0%). After a minimum follow up of 2 years (rTHA 1,470 (735; 3,738) days; rTKA 1,474 (749; 4,055) days). During the 2-year follow-up, 8 patients died and 5 were lost to follow-up. There were 54/219 (24.7%) re-revision in rTHa and 20/114 (17.5%) in rTKA. Overall, there were 23 (10.5%) septic re-rTHA and 9 (7.9%) septic re-rTKA as well as 31 (14.2%) aseptic re-rTHA and 11 (9.6%) aseptic re-rTKA. Patients with previous septic revisions bevor UPIC procedure showed a significant higher risk for septic re-revision (p<0.05). Moreover, there were less septic re-revisions after single culture positive UPIC (rTHA: 16/173 (9.2%); rTKA 6/99 (6.1%)) compared to ≥2 positive intraoperative cultures UPIC (rTHA: 7/46 (15.2%); rTKA 3/15 (20.0%)). The most common reason for re-revision in the rTHA-group was aseptic loosening of the cup (34.2%) or of the stem (23.3%), dislocation (18.3%) and periprosthetic-fractures (7.8%). In the rTKA-group it was aseptic loosening (40.4%), instability (24.6%) and secondary patella resurfacing (7.9%). There was a higher septic re-revision rate in consecutive revisions than in planned revisions 17.3% vs. 8.5% in the rTHA-group and 14.3% vs. 7.5% in the rTKA-group, p<0.001. Conclusion. UPICs are common in rTJA. The rate was higher in hips which may partly explained by the easier pre op joint aspiration in the knee. UPIC may lead to an increase in subsequent re-revisions


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_5 | Pages 7 - 7
1 Apr 2022
Lu W Oomatia A Muderis MA
Full Access

Introduction. Osseointegration is a potential treatment option for transfemoral amputees experiencing socket related problems. Till this date, there is little data assessing the feasibility and advantages of osseointegration in individuals with transtibial amputations. Materials and Methods. We prospectively followed 91 patients undergoing transtibial osseointegration from 2014–2018 who either 1) reported pain or mobility dissatisfaction with socket prosthesis; 2) had an intact limb with incapacitating pain, complex deformity, or profound distal weakness or 3) were recent amputees preferring osseointegration. Adverse events were monitored including infection, periprosthetic fracture, implant breakage, aseptic loosening, revision surgery/additional amputation and death. Functional outcomes were measured using the Questionnaire of persons with a Trans-femoral amputation (Q-TFA) and mobility was assessed using Six Minute Walk Test (6MWT) and Time Up and Go (TUG). Results. Following osseointegration surgery, there was a significant increase in the Q-TFA global score, the 6MWT and the K-levels during follow-up. At one year following Osseointegration surgery, all patients were pain-free, the 11 patients who were wheelchair-bound prior to surgery were ambulatory, and the other 27 patient unable to walk prior to surgery, demonstrated improved mobility. There were 7 cases of implant removals due to pain and loosening and 10 cases of revisions within an average of 1.8 years, of which 1 was aseptic loosening, 6 due to infection, 1 failure to integrate and 2 implant fractures. No periprosthetic bone fractures occurred. Conclusions. Transtibial osseointegration results in improved functional outcomes after amputation. Complications are manageable and should decrease with surgical and implant improvements


Full Access

We report the outcome of 320 primary Total Hip Arthroplasties (THA) with minimum 10-year follow-up (range 10–17 years, mean 12.6 years), performed by a single surgeon in Tauranga New Zealand, with the Exeter Contemporary Flanged all-polyethylene cup and Exeter femoral stem via a posterior approach. The aim of the study is to compare the results with the published results from the design centre and create a baseline cohort for further outcomes research in this centre. All patients were prospectively followed at 6 weeks, 1 year, 5 years, 10 years, (and 15 years when available). Of 333 cases that matched the inclusion criteria, 13 procedures in 12 patents were excluded because of concomitant bone grafting and/or supplementary cage fixation, leaving 320 primary THA procedures in 280 patients, including 26 bilateral procedures in 13 patients. Mean follow-up of the surviving cases was 12.6 (range 5.0-17.1) years. There were 12 revisions – 2 for fracture, 5 for instability, 1 for impingement pain and 4 for infection. There were no revisions for aseptic cup loosening. Kaplan-Meier survivorship with revision for aseptic loosening as the endpoint was 100% at 15.0 years (with minimum 40 cases remaining at risk). All-cause acetabular revision in 12 cases result in a Kaplan-Meier survival of 95.9% (95% CI: 93.5 to 98.3%). Cemented THA with the Exeter Contemporary Flanged cup and the Exeter stem is a durable combination with results that can be replicated outside of the design centre. The Exeter Contemporary Flanged cup has excellent survivorship at 15 years when used with the Exeter stem. Cemented THA with well-proven components should be considered the benchmark against which newer designs and materials should be compared


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_2 | Pages 3 - 3
1 Mar 2022
Guta D Santini A Fountain J Scott S Rourke H Davidson J Folb J
Full Access

Aims. The International Consensus Meeting on Musculoskeletal Infection (ICM, Philadelphia 2018) recommended histology as one of the diagnostic tests although this is not routinely used in a number of UK hospitals. This study aims to explore the role of histology in the diagnosis of infection and whether it is of practical use in those cases where the microbiology samples are either diagnostically unclear or do not correspond to the pre-operative diagnosis or the clinical picture. Patients and Methods. We identified 85 patients who underwent revision knee arthroplasty for either septic or aseptic loosening and for whom both microbiology and histology samples were taken. The procedures were performed by the senior experienced surgeons specialised in revision knee arthroplasty in two centres from Liverpool. Each patient had a minimum of five tissue samples taken, using separate knife and forceps and each sample was divided in half and sent for microbiology and histology in different containers. Fifty-four patients (63.5%) underwent a single-staged revision; ten patients (11.8%) underwent the 1. st. stage of a two staged revision; eleven patients (12.9%) underwent the 2. nd. stage of a two staged revision; one patient (1.2%) underwent an additional revision stage; three patients (3.5%) were treated with a DAIR; three patients (3.5%) had a 2-in-1 revision; two patients (2.4%) had a debridement and polyethylene exchange; and one patient (1.2%) had an arthroscopy biopsy of knee replacement. The cost to process five microbiology samples for each patient was £122.45 on average and for the five histology samples was £130. Results. In 63.5% (n=54) the histology and microbiology confirmed an aseptic joint as suspected beforehand. In 8.2% (n=7) the histology result was the same as the microbiology result confirming infection as suspected beforehand. In 15.3% (n=13) where asepsis was suspected beforehand, one of the five microbiology samples unexpectedly grew an organism but all the histological samples showed no evidence of infection. In these cases, the histology result supported the diagnosis of the likelihood of a contaminant. In 5.9% (n=5) we found differences in the microbiology and histology in one sample and in 7.1% (n=6) the histology was different to the microbiology in more than one sample. Conclusions. In cases where the diagnosis of sepsis within a knee replacement is not in doubt due to pre-operative microbiology, we found no benefit in additional histology sampling. In 28.3% of the cases, the histology was of use in the diagnosis of infection in complex cases and a useful tool in the decision process for further management. In over half of the cases where the revision was for aseptic loosening, the histology result did not alter the management but 28.3% of cases that were thought to be aseptic, microbiology revealed at least one positive sample hence the histology was of use in making a final diagnosis, be that of infection, contamination or to rule out infection. Whilst histology is of use in the latter groups but not the aseptic group, these outcomes are not predictable until after the post-operative period hence histology is required in all these cases. Overall, the histology is a cheap test which is of benefit in the diagnosis of complex peri-prosthetic joint infection in one–third of cases and we support the ICM recommendation


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 51 - 51
23 Feb 2023
Full Access

Dual mobility is a French concept that appeared in the 1970s and was initially intended to reduce dislocation rates. In recent years, this concept has evolved with new HA titanium spray coatings, new external macrostructures, and better-quality polyethylene. This has allowed to extend the indications to younger and therefore active populations. The objective of our work is to analyze at least 10 years a homogeneous and continuous series of 170 primary total hip replacements associating a latest generation Novae Sunfit. ®. dual mobility cup with a straight femoral stem. Only primary arthroplasties for osteoarthritis or necrosis were included. Total hip arthroplasty was always performed through a posterolateral approach. All patients had regular clinical and radiological follow-up. The average follow-up in our series was 11.5 years. The average age of the population is 71 years. At the last follow-up, there were 17 deaths, 6 losses to follow up and 9 adverse events, including 1 cup change for psoas impingement and 1 dislocation. The low rate of dislocation at 11 years confirms the high stability of the dual mobility, which should be recommended for primary procedure for patients at high risk of postoperative instability. The lack of intraprosthetic dislocation due to wear at 11 years of follow-up highlights the good quality of the latest generation of polyethylene, and the need to combine high-polished surfaces and a refined femoral neck with a dual mobility cup. Finally, the lack of aseptic loosening confirms the quality of the secondary fixation of these implants and justifies their wider use in all patients


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_5 | Pages 79 - 79
1 Apr 2018
Lee W Han C Yang I Park K
Full Access

Introduction. Reinforcement ring with allograft bone is commonly used for acetabular reconstruction of bone defects because it can achieve stable initial fixation of the prosthesis. It is not clear whether the allograft bone can function as a viable host bone and provide long-standing structural support. The purpose of this study was to assess to long-term survival of the reinforcement rings and allograft bone incorporation after acetabular revisions. Methods. We retrospectively reviewed 39 hips (37 patients) who underwent reconstruction of the acetabulum with a Ganz reinforcement ring and allograft bone in revision total hip arthroplasty. There were 18 females and 19 males with a mean age of 55.9 years (35–74 years). The minimum postoperative follow-up period was 10 years (10∼17 years). We assessed the acetabular bone defect using the Paprosky's classification. We determined the rates of loosening of the acetabular reconstructions, time to aseptic loosening, integration of the allograft bone, resorption of the allograft bone, and survival rate. Aseptic loosening of the acetabular component was defined as a change in the cup migration of more than 5 mm or a change in the inclination angle of more than 5° or breakage of the acetabular component at the time of the follow-up. Graft integration was defined as trabecular remodelling crossing the graft-host interface. Resorption of the allograft bone was classified as minor (<1/3), moderate (1/3–1/2) or severe (>1/2). Kaplan-Meier survivorship analysis was performed for aseptic loosening of the acetabular component. The results. The acetabular bone defects were classified as follows: 8 type II hips (4 type IIB, 4 type IIC), and 31 type III hips (17 type IIIA, 14 type IIIB). Fourteen (35.9%) of 39 hips was defined as aseptic loosening of an acetabular component. Loosening was more frequent in type IIIB (57.1%) than in type IIIA hips (29.4%). Mean time to aseptic loosening of the acetabular reconstructions was 6.3 years in type IIIA and from 5 years in type IIIB defects, respectively. Allograft bone incorporation was satisfactory in 66.7% of hips. There was minor bone resorption in 14.3% and moderate bone resorption in 10.2%. In 9 hips (23.1%), severe resorption of the allograft bone was observed and early component loosening was observed in these cases. The survival rate of acetabular component at 10 years of follow-up was 63.6% (95% confidence interval, 49–77%) with aseptic loosening as endpoints. Conclusions. The long-term survival rate of acetabular revision using the reinforcement ring and allograft bone in the reconstruction of severe acetabular bone defects was unsatisfactorily low due to loosening of acetabular components. Because of unfavorable graft incorporation into a host bone, an alternative component and structural support may be employed in the reconstruction of severe acetabular bone defects


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_11 | Pages 43 - 43
1 Nov 2022
Nebhani N Kumar G
Full Access

Abstract. Extended Trochanteric Osteotomy (ETO) improves surgical exposure and aids femoral stem and bone cement removal in Revision Total Hip Replacement (RTHR) surgery. The aim of this study was to identify healing rates and complications of ETO in RTHR. Methods. From 2012 to 2019 we identified patients who underwent ETO for RTHR. Data collected demographics, BMI, diabetes, anticoagulants, indication for ETO, surgical approach, length of ETO and complications. Descriptive analysis of patient demographics, multiple linear regression analysis was performed to assess ETO complications. Results. There were 63 patients with an average age of 69 years. Indications for ETO were aseptic loosening (30), infection (15), periprosthetic fracture (9), recurrent dislocation (5), broken implant (4). There were 44 cemented and 19 uncemented femoral stem that underwent ETO. Average time from index surgery was 12 years (less than a year to 38 years). All procedures were through posterolateral approach and all ETO were stabilised with cables. Average length of ETO was 12.5cm. BMI varied from 18 to 37. There were 5 diabetics and 16 on anticoagulants. All but one ETO went on to unite. Other complications included infection, dislocations, lateral thigh pain and significant limp. Discussion. Fixation of ETO can be with either wires or cables or plate with cables/screws. Advantages of cables are no irritation over greater trochanter, no disruption of gluteus medius/vastus lateralis continuity, reproducible tension in cables and use of torque limiter minimises loss of tension in cables