Aims. Several radiological methods of measuring
Aims. The aim of this study was to assess the reproducibility and validity
of cross table radiographs for measuring the
Aims. Femoral component
Purpose:. In order to acquire good stability of an arthroplasty hip, the proper placement of the implants, which prevents impingement between the stem neck and the socket, is important. In general, the
Aims. The aim of this study was to evaluate the suitability of the tapered cone stem in total hip arthroplasty (THA) in patients with excessive femoral anteversion and after femoral osteotomy. Methods. We included patients who underwent THA using Wagner Cone due to proximal femur anatomical abnormalities between August 2014 and January 2019 at a single institution. We investigated implant survival time using the endpoint of dislocation and revision, and compared the prevalence of prosthetic impingements between the Wagner Cone, a tapered cone stem, and the Taperloc, a tapered wedge stem, through simulation. We also collected Oxford Hip Score (OHS), visual analogue scale (VAS) satisfaction, and VAS pain by postal survey in August 2023 and explored variables associated with those scores. Results. Of the 58 patients (62 hips), two (two hips) presented with dislocation or reoperation, and Kaplan-Meier analysis indicated a five-year survival rate of 96.7% (95% CI 92.4 to 100). Mean stem
The purposes of this study were to report the accuracy of stem
Introduction. In recent literatures dealing with optimisation of prosthetic alignment in total hip arthroplasty (THA), the concept of combined
Aims. Cross-table lateral (CTL) radiographs are commonly used to measure acetabular component
Introduction. Femoral stem
Aims. Pelvic tilt (PT) can significantly change the functional orientation of the acetabular component and may differ markedly between patients undergoing total hip arthroplasty (THA). Patients with stiff spines who have little change in PT are considered at high risk for instability following THA. Femoral component position also contributes to the limits of impingement-free range of motion (ROM), but has been less studied. Little is known about the impact of combined
We have previously reported on the improved all-cause revision and improved revision for instability risk in lipped liner THAs using the NJR dataset. These findings corroborate studies from the Australian (AOANJRR) and New Zealand (NZOA) joint registries. The optimal orientation of the lip in THAs utilising a lipped liner remains unclear to many surgeons. The aim of this study was to identify impingement-free optimal liner orientations whilst considering femoral stem version, cup inclination and cup version. A cementless THA kinematic model was developed using a 20 degree XLPE liner. Physiological ROM and provocative dislocation manoeuvre analyses were performed. A total of 9 cup positions were analysed (inclination 30–40–50 degrees,
Introduction. The correct
Introduction. Cross table lateral (CTL) radiographs are commonly used to measure acetabular component
The purpose of this study was to investigate the influence of surgical approach on femoral stem version in THA. This was a retrospective database review of 830 THAs in 830 patients that had both preoperative and postoperative CT scans. All patients underwent staged bilateral THAs and received CT-based 3D planning on both sides. Stem version was measured in the second CT-scan and compared to the native neck axis measured in the first CT-scan, using the posterior condyles as the reference for both. Cases were performed by 104 surgeons using either a direct anterior (DAA, n=303) or posterior (PA, n=527) approach and one of four stem designs: quadrangular taper, calcar-guided short stem, flat taper and fit-and-fill. Sub-analyses investigated changes in version for low (≤5°), neutral (5–25°) and high (≥25°) native version subgroups and for the different implant types. Native version was not different between approaches (DAA = 12.6°, PA = 13.6°, p = 0.16). Overall, DAA stems were more anteverted relative to the native neck axis vs PA stems (5.9° vs 1.4°, p<0.001). This trend persisted in hips with high native version (3.2° vs -5.3°, p<0.01) and neutral native version (5.3° vs 1.3°, p<0.001), but did not reach significance in the low native version subgroup (8.9° vs 5.9°, p=0.13). Quadrangular taper, calcar-guided, and flat taper stem types had significantly more
Introduction. To control
INTRODUCTION. In total hip arthroplasty, preoperative planning is almost indispensable. Moreover, 3-dimensional preoperative planning became popular recently.
Progressive retroversion of a cemented stem is
predictive of early loosening and failure. We assessed the relationship
between direct post-operative stem
Introduction: Template use prior to hip arthroplasty is a valuable form of pre-operative planning. The femoral neck
Introduction. Traditional methods of component positioning in total hip replacement (THR) utilize mechanical alignment guides which estimate position relative to the plane of the operating room table. However, variations in pelvic tilt alter the relationship between the anatomic plane of the pelvis and that of the table such that components placed in optimal position relative the table may not land within the classic anatomic “safe zone” described by Lewinnek. It has been suggested that navigation software should incorporate adjustments for the degree of pelvic tilt. Current imageless navigation software has this capability, however there is a paucity of data regarding the accuracy of this technology. Purpose. We aimed to assess the accuracy of intra-operative pelvic tilt adjusted
Introduction. The posterior condylar axis of the distal femur is the common reference used to describe femoral anteversion. In the context of Total Hip Arthroplasty (THA), this reference can be used to define the native femoral anteversion, as well as the