Advertisement for orthosearch.org.uk
Results 1 - 20 of 110
Results per page:
Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_8 | Pages 78 - 78
1 Aug 2020
Marwan Y Martineau PA Kulkarni S Addar A Algarni N Tamimi I Boily M
Full Access

The anterolateral ligament (ALL) is considered as an important stabilizer of the knee joint. This ligament prevents anterolateral subluxation of the proximal tibia on the femur when the knee is flexed and internally rotated. Injury of the ALL was not investigated in patients with knee dislocation. The aim of the current research is to study the prevalence and characteristics of ALL injury in dislocated knees. A retrospective review of charts and radiological images was done for patients who underwent multiligamentous knee reconstruction surgery for knee dislocation in our institution from May 2008 to December 2016. Magnetic resonance imaging (MRI) was used to describe the ALL injury. The association of ALL injury with other variables related to the injury and the patient's background features was examined. Forty-eight patients (49 knees) were included. The mean age of the patients was 32.3 ± 10.6 years. High energy trauma was the mechanism of dislocation in 28 (57.1%) knees. Thirty-one knees (63.3%) were classified as knee dislocation (KD) type IV. Forty-five (91.8%) knees had a complete ALL injury and three (6.1%) knees had incomplete ALL injury. Forty (81.6%) knees had a complete ALL injury at the proximal fibres of the ALL, while 23 (46.9%) knees had complete distal ALL injury. None of the 46 (93.9%) knees with lateral collateral ligament (LCL) injury had normal proximal ALL fibres (p = 0.012). Injury to the distal fibres of the ALL, as well as overall ALL injury, were not associated with any other variables (p >0.05). Moreover, all patients with associated tibial plateau fractures (9, 18.4%) had abnormality of the proximal fibres of the ALL (p = 0.033). High grade ALL injury is highly prevalent among dislocated knees. The outcomes of reconstructing the ALL in multiligamentous knee reconstruction surgery should be investigated in future studies


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 123 - 123
1 Feb 2020
Maeda A Tsuchida M Kusaba A Kondo S
Full Access

The anterolateral MIS-THA approach can be divided into the Modified Watson-Jones approach (MWJ) performed in the lateral position and the Anterolateral Supine method (ALS) performed in the supine position. Femoral preparation is flexible in stem selection in the MWJ method. On the other hand, the ALS method is more stable for placement on the acetabular implant. Now we introduce novel anterolateral MIS approach named AL60, it makes use of the merits of both MWJ and ALS methods. Technique. The patient is fixed at 30 degrees on the dorsal side from lateral position. That is 60 degrees on the half side from the horizontal plane, and the platform of the operating table is removed just as in the MWJ method. During surgery, the pelvis is fixed by the posterior support, and the stability of the pelvis is very good. Also, if the inclination is accurate at 30 degrees, by holding the holder parallel to the operating table when inserting the cup, the cup is theoretically inserted at Anatomical anteversion 30 degrees. The intraoperative field of view is also visible to the assistant due to the semi-lateral position. Femoral preparation is easier than the MWJ method because the affected limbs have fallen to the dorsal side already. Discussion. Since March 2017 to the end of August 2018, the AL60 method was used for 207 primary THA. There were no dislocations or fractures and any other complications. Full weight bearing was possible from the next day. The AL60 method has stability of the ALS method for acetabular preparation and the operability of the MWJ method for femoral preparation. Therefore, it can be said that new AL60 approach method makes use of the merits of both MWJ and ALS methods


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_21 | Pages 64 - 64
1 Dec 2016
Corbo G Lording T Burkhart T Getgood A
Full Access

Injury to the anterolateral ligament (ALL) has been reported to contribute to high-grade anterolateral laxity following anterior cruciate ligament (ACL) injury. Failure to address ALL injury has been suggested as a cause of persistent rotational laxity following ACL reconstruction. However, lateral meniscus posterior root (LMPR) tears have also has been shown to cause increased internal rotation and anterior translation of the knee. Due to the anatomic relationship of the ALL and the lateral meniscus, we hypothesise that the ALL and lateral meniscus work synergistically, and that a tear to the LMPR will have the same effect on anterolateral laxity as an ALL tear in the ACL deficient knee. Sixteen fresh frozen cadaveric knee specimens were potted into a hip simulator(femur) and a six degree-of-freedom load cell (tibia). Two rigid optical trackers were inserted into the proximal femur and distal tibia, allowing for the motion of the tibia with respect to the femur to be tracked during biomechanical tests. A series of points on the femur and tibia were digitised to create bone coordinate systems that were used to calculate the kinematic variables. Biomechanical testing involved applying a 5Nm internal rotation moment to the tibia while the knee was in full extension and tested sequentially in the following three conditions: i) ACLintact; ii) Partial ACL injury (ACLam) – anteromedial bundle sectioned; iii) Full ACL injury (ACLfull). The specimens were then randomised to either have the ALL sectioned first (ALLsec) followed by the LMPRsec or vice versa. Internal rotation and anterior translation of the tibia with respect to the femur were calculated. A mixed two-way (serial sectioning by ALL section order) repeated measures ANOVA (alpha = 0.05). Compared to the ACLintact condition, internal rotation was found to be 1.78° (p=0.06), 3.74° (p=0.001), and 3.84° (p=0.001) greater following ACLfull, LMPRsec and ALLsec respectively. LMPRsec and the ALLsec resulted in approximately 20 of additional internal rotation (p=0.004 and p=0.01, respectively) compared with the ACL deficient knee (ACLfull). No difference was observed between the ALL and LMPR sectioned states, or whether the ALL was sectioned before or after the LMPR (p=0.160). A trend of increasing anterior translation was observed when the 5Nm internal rotation moment was applied up until the ACL was fully sectioned; however, these differences were not significant (p=0.070). The ALL and LMPR seem to have a synergistic relationship in aiding the ACL in controlling anterolateral rotational laxity. High-grade anterolateral laxity following ACL injury may be attributed to injuries of the ALL and/or the LMPR. We suggest that the lateral meniscus should be thought of as part of the anterolateral capsulomeniscal complex (i.e., LM, ITB, and ALL) that acts as a stabiliser of anterolateral rotation in conjunction with the ACL


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 34 - 34
1 Feb 2020
Kim Y Pour AE Lazennec J
Full Access

Purpose. Minimally invasive anterolateral approach (ALA) for total hip arthroplasty (THA) has gained popularity in recent years as better postoperative functional recovery and lower risk of postoperative dislocation are claimed. However, difficulties for femur exposure and intraoperative complications during femoral canal preparation and component placement have been reported. This study analyzes the anatomical factors likely to be related with intraoperative complications and the difficulties of access noted by the surgeons through a modified minimally invasive ALA. The aim is to define the profile for patient at risk of intraoperative complications during minimally invasive ALA. Methods. We retrospectively included 310 consecutive patients (100 males, 210 females) who had primary unilateral THA using the same technique in all cases. The approach was performed between the tensor fascia lata and the gluteus medius and minimus, without incising or detaching muscles and tendons. Posterior translation was combined to external rotation for proximal femur exposure (Fig. 1). All patients were reviewed clinically and radiologically. For the radiological evaluation, all patients underwent pre- and postoperative standing and sitting full-body EOS acquisitions. Pelvic [Sacral slope, Pelvic incidence (PI), Anterior pelvic plane angle] and femoral parameters were measured preoperatively. We assessed all intraoperative and postoperative complications for femoral preparation and implantation. Intraoperative complications included the femoral fractures and difficulties for femoral exposure (limitations for exposure and lateralization of the proximal femur). The patients were divided into two groups: patients with or without intraoperative complications. Results. Ten patients (3.2%) had intraoperative femoral fractures (greater trochanter: 2 cases, calcar: 8 cases). Five fractures required additional wiring. Difficult access to proximal femur was reported in the operative records for 10 other patients (3.2%). There was no difference in diagnosis, age, sex, BMI between the patients with or without intraoperative complications. No significant group differences were found for surgical time, and blood loss. Patients with intraoperative complication, presented a significantly lower pelvic incidence than patients without intraoperative complications (mean PI: 39.4° vs 56.9°, p<0.001). The relative risk of intraoperative complications in patients with low PI (PI<45°) was more than thirteen times (relative risk; 13.3, 95% CI= 8.2 to 21.5. p<0.001) the risk for patients with normal and high PI (PI>45°). Conclusions. Anterolateral approach for THA implantation in lateral decubitus is reported to have anatomical and functional advantages. Nevertheless, the exposure of the femur remains a limitation. This study highlights a significant increased risk in case of low PI less than 45°. This specific anatomical pattern reduces the local working space as the possibility for posterior translation and elevation of the proximal femur is less on a narrow pelvis. This limitation is due to the length and the orientation of the hip abductor and short external rotator muscles related to the relative positions of iliac wing and greater trochanter (Fig. 2). This study points out the importance of pelvic incidence for the detection of anatomically less favourable patients for THA implantation using ALA. For any figures or tables, please contact the authors directly


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 16 - 16
1 Jan 2013
Mahmood A Shivarathre D Platt S Hennessy M
Full Access

Background. Cartilage lesions in chronic lateral ligament deficiency are common with the incidence rates mentioned in the previous literature up to 30%. However, other intra-articular pathologies in the unstable ankle have received little attention. Anterolateral impingement associated with synovitis and scarring is a less recognised feature in the treatment of chronic instability. The aim of our study was to ascertain the incidence of chondral and anterolateral impingement lesions in the symptomatic lateral ligament complex deficiency. Methods. We performed a retrospective study of all consecutive patients who underwent modified Brostrom repair for symptomatic recurrent instability of the ankle. All patients underwent a MRI scan prior to surgery. Arthroscopy was performed in all the patients before lateral ligament reconstruction. Seventy seven patients with 78 ankles were included in the study. Patients who had previous ankle surgery or inflammatory arthropathy were excluded. Data was obtained from clinical and radiological records. Arthroscopic findings were recorded in detail during the surgery. Results. The mean age was 29.8 years (Range 18.2–58 yrs). There were 44 females and 34 males in the study. The incidence of chondral lesions were 11.5% (9 out of 78 ankles). The commonest site for chondral defect was the anteromedial talar dome. The incidence of anterolateral impingement which required arthroscopic debridement was 48.7 %(38 ankles). A further 10 ankles revealed non-specific synovitis and scarring which was debrided. The sensitivity and specificity of the MRI scans in the assessment of chondral lesions is 91% and 100%. Conclusion. The incidence of chondral lesions in chronic ankle instability is lower than previously published literature. However, soft tissue impingement lesions have a much higher incidence and require debridement. Arthroscopic examination and debridement of impingement prior to lateral ligament reconstruction of the ankle is quintessential in the management of chronic anterolateral instability


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_10 | Pages 14 - 14
1 May 2016
Sasaki T Kodama T Ogawa Y
Full Access

Introduction. Most Japanese patients who receive total hip arthroplasty (THA) are osteoarthritic and 70% have development dysplasia of the hip. Their stature is shorter than average and their sizes (acetabular cup and femoral stem) are smaller. The Taperloc Microplasty (BIOMET) is a short femoral stem. It was launched on July 2012 in Japan (extended on January 2013). It is essentially a shortened version of the Taperloc stem (35mm shorter than the standard stem). Objectives. We aimed to evaluate the outcomes of minimally invasive anterolateral THA using a short stem. Methods. We retrospectively reviewed all 56 patients who underwent THA at our hospitals between July 2013 and April 2015. Of these 28 (50%) were performed with short stems. The surgical approach was antero-lateral in the lateral position. The patients (4 men and 24 women) had a mean age at surgery of 66.5 years (range, 46–85 years). The original diseases were osteoarthritis (25 patients) and osteonecrosis (3 patients). We investigated the system type, size (cup, femoral head, and stem), radiological findings and complications (fracture, infection, deep vein thrombosis, and dislocation). Results. There were no severe complications, such as, infection, deep vein thrombosis, or dislocation. One patient had a femur fracture during operation and was switched to a standard stem. The mean surgery duration was 102 minutes (range, 80–142 minutes) and the mean amount of bleeding during surgery was 254 g (range, 95–720 g). Mean cup size was 51.0 mm (range, 48–60 mm) and stem size is 6 (range, 4–13). Radiological findings showed 2 patients had stem subsidence (within 5mm). One of them had severe osteoporosis and the other patient had leg length discrepancy. Conclusions. Minimally invasive anterolateral THA using a short femoral stem has good clinical and radiological results in Japanese patients. Long-term results should be further observed prospectively


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 89 - 89
1 Mar 2013
Kaneko H Hoshino Y Saito Y Utajima D Tsuji T Tsukimura Y Abe H Chiba K
Full Access

Introduction. Since2007, we have used CT-based fluoroscopy-matching navigation system (Vector Vision Hip Ver.3.5.2, BrainLAB, Germany) in Total hip arthroplasty. This system completes the registration procedure semi-automatically by matching the contours of fluoroscopic images and touching 3 adequate points to the contours of 3D bone model created in the computer. Registration procedure using fluoroscopic figures has finished before making surgical incision. It needs no elongation time during the operation. The accuracy of navigation system depends on the techniques of registration used for the navigation and secure fixation of the dynamic reference markers. These could be affected by the different type of approaches. The objective of this study was to evaluate the accuracy of CT-based fluoroscopy-matching navigation system in THA and compare the cup position by anterolateral and posteolateral approaches. Material and method. We analysed the acetabular cup in consecutive 132 hips with both intra-operative and post-operative alignment data (based on navigation system and CT evaluation), including 65 cases with anterolateral approach(Modified Watson Jones) (Group AL) and 67 cases with posterolateral approach(Group PL). We aimed the cup angle for THA as following, the inclination: 40 degrees, the anteversion: 20 degrees. Anteversion on the navigation system must be adjusted by the pelvic tilt. Results. The average of the operative time were 84.8 ± 13.5 in group AL and 89.3 ± 15.1 minutes in group PL. There was one dislocation in group AL. There was no other obvious complication (nerve palsy, VTE and Infection) in these two groups. The all cup alignments were within 8 degrees from the preoperative orientation. The differences between the intra- and post-operative measurement of cup inclination were 1.9 ± 1.6 degrees in group AL and 2.1 ± 1.1 degrees in group PL(N.S.). The differences between the intra- and post-operative measurement of cup anteversion were 2.3 ± 1.4 degrees in group AL and 2.2 ± 1.3 degrees in group PL (N.S.). Discussion. CT-based navigation THA is very useful for severe deformity of hip osteoarthritis. We had used CT-based navigation system(landmark matching) since 2003. It needs some technical skills to improve the accuracy of landmark matching. The registration with CT-based fluoroscopy-matching navigation system is much easier and more simple than with landmark matching navigation system. And we found this system provided high accuracy even in severe deformity cases. There was no significant difference with anterolateral and posterolateral approaches by using CT-based fluoroscopy-matching navigation system


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_20 | Pages 23 - 23
1 Dec 2017
Sakai T Hamada H Murase T Takao M Yoshikawa H Sugano N
Full Access

The purpose of this experimental study was to elucidate the accuracy of neck-cut PSG setting, and femoral component implantation using neck-cut PSG in the THA through the anterolateral-approach relative to the preoperative planning goals, and to determine the usefulness of PSG compared with the procedure without PSG. A total of 32 hips from 16 fresh Caucasian cadaveric samples were used and classified into 4 groups: cementless anatomical stem implantation with wide-base-contact PSG (AWP: 8 hips, Fig.2); (2) cementless anatomical stem implantation with narrow-base-contact PSG (ANP: 8 hips, Fig.2); (3) cementless anatomical stem implantation without PSG (Control: 8 hips); and (4) cementless taper-wedge stem implantation with wide-base-contact PSG (TWP: 8 hips). The absolute error of PSG setting in the sagittal plane of the AWP group was significantly less than that of the ANP (p=0.003).THA with wide-base- contact PSG resulted in better alignment of the femoral component than THA without PSG or with narrow- base-contact PSG. Although the neck-cut PSG did not control the sagittal alignment of taper-wedge stem, the neck-cut PSG was effective to realise the preoperative coronal alignment and medial height for THA via the anterolateral approach regardless of the femoral component type. For figures and tables, please contact authors directly


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 93 - 93
1 Jan 2016
Kato M Shimizu T
Full Access

The Dall approach is a modified anterolateral approach with osteotomy of the anterior part of the greater trochanter. This approach relatively preserves the soft tissue tension during total hip arthroplasty (THA). We insert the stem and select a ball neck size so as to have a stable hip which will not dislocate easily during the trial reduction. The aim of this study is to evaluate the adequacy of this method, to measure leg length discrepancy and offset discrepancy at postoperative radiographs. We selected patients for inclusion in this study from those who have more than a 120 degree of affected hip flection angle, the opposite hip is almost normal with a low leg length discrepancy (primary OA, osteonecrosis, Crowe 1 secondary OA, femoral neck fracture). All THA were performed with cement fixation using an alignment guide to ensure accurate acetabular positioning. The ball head's diameter used were all 26mm. From September 2011 to October 2013, 22 patients met inclusion criteria among 103 THA. The mean age for 22 subjects was 66.6±12 years. The mean flexion angle of preoperative hip joints was 127.2±6.1 degrees. The cup inclination was 43.8° ± 3.5°. Anteversion was 11.8°±6°. The mean preoperative leg length discrepancy was 5.8mm±6.3mm. The mean postoperative leg length discrepancy was 0.7±3.5mm. The mean postoperative offset discrepancy was 0.7±6.6mm. There were no dislocations in this series of 103 cases. Discussion. Dislocation and leg length discrepancies are major complications following a total hip arthroplasty. A good range of motion of the preoperative hip joint is considered a high risk dislocation factor. The Dall approach with minimal release of soft tissue related to a tension of hip joint offers maximal stability and the ability to accurately restore leg length


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 152 - 152
1 Jan 2013
Lidder S Masterson S Grechenig S Pilsl U Tanzer K Clements H
Full Access

Percutaneous plating of the distal tibia via a limited incision is an accepted technique of osteosynthesis for extra-articular and simple intra-articular distal tibia fractures. In this study we identify structures are risk during this approach. Method. Thirteen unpaired adult lower limbs were used for this study. Thirteen, 16-hole synthes®LCP anterolateral distal tibial plates were percutaneously inserted according to the manufacturer instructions and confirmed by xray. Dissection was performed around the plate to examine the relation of nerves and soft tissue. Results. The neurovascular bundle was under the plate in one case. Over the horizontal limb of the plate, typically the superficial peroneal nerve had a variable course over all four screw holes. The anterior tibial artery coursed over hole number 3 and the Extensor hallucis longistendon was positioned over hole 3 or 4. The Anterior tibialis tendon skirted hole 4 in 12 cases. Over the vertical limb of the plate, the neurovascular bundle coursed over holes, 5 to 7, the superficial peroneal nerve over holes 5 to 7. Discussion. Meticulous attention is required when placing an anterolateral distal tibia plate using a MIPO technique. We recommend a larger initial incision to avoid entanglement of the superficial peroneal nerve under the plate. Over the anterior aspect of the tibia, an open technique with adequate neurovascular structure and tendon protection is necessary due to the variability of structure coursing over the plate. A bridging technique for placement of proximal locking screw should be made through a mini open incision and this is safe to do so proximally over holes 12 to 16. Caution is advised during placement of screws percutaneously from holes 1 to 12 however the neurovascular bundle courses commonly over holes 5 to 7. These landmarks also apply to the use of shorter anterolateral distal tibial plates


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 40 - 40
1 Apr 2019
Elkabbani M El-Sayed MA Tarabichi S Malkawi AS Schulte M
Full Access

Aim. The objective of this study was to evaluate the intermediate term clinical and radiological results of a new short stem hip implant. Methods. In 20 consecutive patients suffering from osteoarthritis with 25 affected hip joints (five cases were bilateral), the clinical and radiological results of 25 hip arthroplasties performed in one hospital between October 2009 and May 2014 through a minimally invasive anterolateral approach using a cementless short stem prosthesis type Aida and a cementless cup type Ecofit with a ceramic on ceramic pairing were evaluated prospectively. The median age of patients at time of surgery was 60 years (range, 42–71 years), 15 male (4 were bilateral) and 5 female patients (one was bilateral) were included in the study. The median clinical follow up was 30 months (range, 2–88 months), and the median radiological follow up was 30 months (range, 2–88 months). Results. Harris Hip Score improved from a median preoperative value of 53 to a median postoperative value of 96 (range, 73–100) at follow up. 22 hips (88%) showed an excellent postoperative Harris Hip Score, 2 hips (8%) a good postoperative Harris Hip Score, and one hip (4%) a fair postoperative Harris Hip Score. Only two patients complained of postoperative thigh pain. Regarding patient satisfaction, 15 patients (60%) were very satisfied, 10 patients (40%) were satisfied. None was unsatisfied. Radiological analysis showed that 19 stems (76%) were with stable bony ingrowth, two cases (8%) showed stable fibrous ingrowth. Four cases need further follow up for proper evaluation of stem fixation.(See Figures 1,2,3). Conclusion. The intermediate term survival of this new short stem is very promising, and achieving the goals of a standard hip arthroplasty. For any figures or tables, please contact the authors directly


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_10 | Pages 79 - 79
1 May 2016
Totsuka S Mishima H Wada H Yoshizawa T Sugaya H Nishino T Yamazaki M
Full Access

Introduction. Migration of the trial femoral head is a rarely occurring complication of total hip arthroplasty (THA) performed using the anterolateral approach (ALA). This migration of the trial femoral head under the rectus femoris is extremely risky because of the anatomical situation. Analyzing the morphological character of a case of migration may help us to avoid this risk. Objective. We analyzed the three-dimensional bone morphology using computed tomography (CT) scan images to investigate the physiological characteristics of five migration cases. Methods. We examined 108 patients (21 men, 87 women, 113 hips) who underwent THA via the ALA. The average patient age was 62.9 (range: 30–87) years and average body mass index was 24.4 (range: 18.0–36.0) kg/m2. The exclusion criteria were dysplastic coxarthroses greater than Crowe type II, previous fractures, previous hip operations, and muscle disease. Three-dimensional models of the pelvis and femur were made using ZedHip software® (Lexi, Tokyo, Japan). The anterior superior iliac spine on the affected side (A) and contralateral side (A’), anterior inferior iliac spine (I), and greater trochanter tip (G) were noted in these models. The distances A–I, I–G, and A–G and the angle formed by AA’ and AI were measured (Figure 1, 2). Each hip was classified by the presence (group M) or absence (group N) of migration during surgery. A Fisher's exact probability test, Student's t-test, and Welch's t-test were used to compare the two groups, and p-values less than 0.05 were considered significant. Results. In 5 of the 113 hips, the trial femoral heads migrated under the rectus femoris and were removed safely. No significant differences were found between the gender, height, weight, or BMI of the groups. The average A–I distance was 32.3±3.0 mm (mean±SD) in group M and 39.4±10.4 mm in group N; I–G was 52.2±8.2 mm in group M and 59.7±10.6 mm in group N; and A–G was 64.3±10.3 mm in group M and 76.3±12.3 mm in group N. The average angle formed by AA’ and AI was 50.5±5.8°. Significant differences between the two groups were found for the distances A–I and A–G. Conclusions. In 4.4% of cases, the trial femoral heads migrated under the rectus femoris, which creates a risk for serious complications because major nerve and blood vessels are located nearby. The tendency for migration was expected to be related to the balance between soft tissues. In this study, we found that migration tends to occur in patients with shorter distances between A and I, and A and G. The trial head should be dislocated more carefully in those patients


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLIV | Pages 31 - 31
1 Oct 2012
Hakki S Pedersen K Bui H Webster W Osman M Rodriguez H
Full Access

As much as there is interest in mini-invasive surgery (MIS) total hip arthroplasty (THA), there is controversy ranging from a more advantageous to a potentially dangerous alternative to classic THA. The purpose of this study is to compare the results of 130 cementless, standard stem navigated primary THA with data collected retrospectively from 2005 to 2010 (64 classic Hardinge approach (HAL) and 66 MIS intermuscular anterolateral approach by the senior surgeon). Data include: operative time, perioperative bleeding, length of surgery, hospital stay, patient's satisfaction and pain perception. The alignment values at six months to a maximum of 60 months provided necessary statistical information for clinical and radiological comparison of the two groups. Significant differences were found between the two groups with MIS being superior with respect to less surgical time (p = 0.029) and achieving quicker rehab goals with shorter hospital stay (p <0.001). Pain perception was less in MIS group with a higher satisfaction score (p <0.001). Although both groups have the potential of nerve injury to tensor fascia muscle, it's only the classic HAL that jeopardises the glutei nerve supply. MIS approach to navigated THA seems to be an acceptable alternative with some advantages to Classic HAL


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_15 | Pages 77 - 77
7 Nov 2023
Dey R Nortje M du Toit F Grobler G Dower B
Full Access

Hip abductor tears(AT) have long been under-recognized, under-reported and under-treated. There is a paucity of data on the prevalence, morphology and associated factors. Patients with “rotator cuff tears of the hip” that are recognized and repaired during total hip arthroplasty(THA) report comparable outcomes to patients with intact abductor tendons at THA. The study was a retrospective review of 997 primary THA done by a single surgeon from 2012–2022. Incidental findings of AT identified during the anterolateral approach to the hip were documented with patient name, gender, age and diagnosis. The extent and size of the tears of the Gluteus medius and Minimus were recorded. Xrays and MRI's were collected for the 140 patients who had AT and matched 1:1 with respect to age and gender against 140 patients that had documented good muscle quality and integrity. Radiographic measurements (Neck shaft angle, inter-teardrop distance, Pelvis width, trochanteric width and irregularities, bodyweight moment arm and abductor moment arm) were compared between the 2 groups in an effort to determine if any radiographic feature would predict AT. The prevalence of AT were 14%. Females had statistically more tears than males(18vs10%), while patients over the age of 70y had statistically more tears overall(19,7vs10,4%), but also more Gluteus Medius tears specifically(13,9vs5,3%). Radiographic measurements did not statistically differ between the tear and control group, except for the presence of trochanteric irregularities. MRI's showed that 50% of AT were missed and subsequently identified during surgery. Abductor tears are still underrecognized and undertreated during THA which can results in inferior outcomes. The surgeon should have an high index of suspicion in elderly females with trochanteric irregularities and although an MRI for every patient won't be feasible, one should always be prepared and equipped to repair the abductor tendons during THA


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_10 | Pages 44 - 44
1 Jun 2023
Fossett E Ibrahim A Tan JK Afsharpad A
Full Access

Introduction. Snapping hip syndrome is a common condition affecting 10% of the population. It is due to the advance of the iliotibial band (ITB) over the greater trochanter during lower limb movements and often associated with hip overuse, such as in athletic activities. Management is commonly conservative with physiotherapy or can be surgical to release the ITB. Here we carry out a systematic review into published surgical management and present a case report on an overlooked cause of paediatric snapping hip syndrome. Materials & Methods. A systematic review looking at published surgical management of snapping hip was performed according to PRISMA guidelines. PubMed, MEDLINE, EMBASE, CINAHL and the Cochrane Library databases were searched for “((Snapping hip OR Iliotibial band syndrome OR ITB syndrome) AND (Management OR treatment))”. Adult and paediatric published studies were included as few results were found on paediatric snapping hip alone. Results. 1548 studies were screened by 2 independent reviewers. 8 studies were included with a total of 134 cases, with an age range of 14–71 years. Surgical management ranged from arthroscopic, open or ultrasound guided release of the ITB, as well as gluteal muscle releases. Common outcome measures showed statistically significant improvement pre- and post-operatively in visual analogue pain score (VAPS) and the Harris Hip Score (HHS). VAPS improved from an average of 6.77 to 0.3 (t-test p value <0.0001) and the HHS improved from an average of 62.6 to 89.4 (t-test p value <0.0001). Conclusions. Although good surgical outcomes have been reported, no study has reported on the effect of rotational profile of the lower limbs and snapping hip syndrome. We present the case of a 13-year-old female with snapping hip syndrome and trochanteric pain. Ultrasound confirmed external snapping hip with normal soft tissue morphology and radiographs confirmed no structural abnormalities. Following extensive physiotherapy and little improvement, she presented again aged 17 with concurrent anterior knee pain, patella mal-tracking and an asymmetrical out-toeing gait. CT rotational profile showed 2° of femoral neck retroversion and excessive external tibial torsion of 52°. Consequently, during her gait cycle, in order to correct her increased foot progression angle, the hip has to internally rotate approximately 35–40°, putting the greater trochanter in an anterolateral position in stance phase. This causes the ITB to snap over her abnormally positioned greater trochanter. Therefore, to correct rotational limb alignment, a proximal tibial de-rotation osteotomy was performed with 25° internal rotation correction. Post-operatively the patient recovered well, HHS score improved from 52.5 to 93.75 and her snapping hip has resolved. This study highlights the importance of relevant assessment and investigation of lower limb rotational profile when exploring causes of external snapping hip, especially where ultrasound and radiographs show no significant pathology


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 20 - 20
1 Dec 2022
Ng G El Daou H Bankes M Cobb J Beaulé P
Full Access

Femoroacetabular impingement (FAI) – enlarged, aspherical femoral head deformity (cam-type) or retroversion/overcoverage of the acetabulum (pincer-type) – is a leading cause for early hip osteoarthritis. Although anteverting/reverse periacetabular osteotomy (PAO) to address FAI aims to preserve the native hip and restore joint function, it is still unclear how it affects joint mobility and stability. This in vitro cadaveric study examined the effects of surgical anteverting PAO on range of motion and capsular mechanics in hips with acetabular retroversion. Twelve cadaveric hips (n = 12, m:f = 9:3; age = 41 ± 9 years; BMI = 23 ± 4 kg/m2) were included in this study. Each hip was CT imaged and indicated acetabular retroversion (i.e., crossover sign, posterior wall sign, ischial wall sign, retroversion index > 20%, axial plane acetabular version < 15°); and showed no other abnormalities on CT data. Each hip was denuded to the bone-and-capsule and mounted onto a 6-DOF robot tester (TX90, Stäubli), equipped with a universal force-torque sensor (Omega85, ATI). The robot positioned each hip in five sagittal angles: Extension, Neutral 0°, Flexion 30°, Flexion 60°, Flexion 90°; and performed hip internal-external rotations and abduction-adduction motions to 5 Nm in each position. After the intact stage was tested, each hip underwent an anteverting PAO, anteverting the acetabulum and securing the fragment with long bone screws. The capsular ligaments were preserved during the surgery and each hip was retested postoperatively in the robot. Postoperative CT imaging confirmed that the acetabular fragment was properly positioned with adequate version and head coverage. Paired sample t-tests compared the differences in range of motion before and after PAO (CI = 95%; SPSS v.24, IBM). Preoperatively, the intact hips with acetabular retroversion demonstrated constrained internal-external rotations and abduction-adduction motions. The PAO reoriented the acetabular fragment and medialized the hip joint centre, which tightened the iliofemoral ligament and slackenend the pubofemoral ligament. Postoperatively, internal rotation increased in the deep hip flexion positions of Flexion 60° (∆IR = +7°, p = 0.001) and Flexion 90° (∆IR = +8°, p = 0.001); while also demonstrating marginal decreases in external rotation in all positions. In addition, adduction increased in the deep flexion positions of Flexion 60° (∆ADD = +11°, p = 0.002) and Flexion 90° (∆ADD = +12°, p = 0.001); but also showed marginal increases in abduction in all positions. The anteverting PAO restored anterosuperior acetabular clearance and increased internal rotation (28–33%) and adduction motions (29–31%) in deep hip flexion. Restricted movements and positive impingement tests typically experienced in these positions with acetabular retroversion are associated with clinical symptoms of FAI (i.e., FADIR). However, PAO altered capsular tensions by further tightening the anterolateral hip capsule which resulted in a limited external rotation and a stiffer and tighter hip. Capsular tightness may still be secondary to acetabular retroversion, thus capsular management may be warranted for larger corrections or rotational osteotomies. In efforts to optimize surgical management and clinical outcomes, anteverting PAO is a viable option to address FAI due to acetabular retroversion or overcoverage


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_8 | Pages 116 - 116
1 May 2019
Lewallen D
Full Access

The direct lateral (or anterolateral) approaches to the hip for revision THA involve detachment of the anterior aspect of the gluteus medius from the trochanter along with a contiguous sleeve of the vastus lateralis. Anterior retraction of this flap of gluteus medius and vastus lateralis and simultaneous posterior retraction of the femur creates an interval for division of gluteus minimus and deeper capsular tissues and exposure of the joint. To enhance reattachment of this flap of the anterior portion of the gluteus medius and vastus lateralis back to the trochanter, an oblique wafer of bone can be elevated along with the muscle off of the anterolateral portion of the trochanter. This bony wafer prevents suture pull out when large nonabsorbable sutures are used around or through the fragment and passed into the bone of the trochanteric bed for reattachment during closure. To prevent excessive splitting proximally into the gluteus medius muscle (and resulting damage to the superior gluteal nerve), it is often helpful to extend the muscle split further distally down into the vastus lateralis. This combined with careful elevation of the gluteal muscles off of the ilium (instead of splitting them) helps provide excellent and safe exposure of the entire rim of the acetabulum and access to the supracetabular region for bone grafting, acetabular augment placement and even fixation of the flanges of a cage. A simple method for posterior column plating via the anterolateral approach involves contouring of the distal end of the plate around the base of the ischium at the inferior edge of the socket. When an extended osteotomy of the femur is needed to correct deformity, remove a well-fixed implant or cement, the “extensile” variation of this same surgical approach involves a Wagner style (lateral to medial) osteotomy of the greater trochanter and proximal femur. The anterior portion of the femur after it is osteotomised is elevated as a separate segment while maintaining the soft tissue attachments to the bone as much as possible to aid osteotomy healing. After implant or cement removal, this approach gives excellent direct access to the distal femur for placement of a long stem revision femoral component without bone-implant conflict proximally because of the bow of the femur. The anterolateral approach (and extensile variants detailed above) can be used routinely and safely in the full range of revision THA procedures, or it can be employed selectively, if desired, in cases at increased risk for dislocation


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_15 | Pages 53 - 53
1 Dec 2021
Osinga R Eggimann M Lo S Kühl R Lunger A Ochsner PE Sendi P Clauss M Schaefer D
Full Access

Aim. Reconstruction of composite soft-tissue defects with extensor apparatus deficiency in patients with periprosthetic joint infection (PJI) of the knee is challenging. We present a single-centre multidisciplinary orthoplastic treatment concept based on a retrospective outcome analysis over 20 years. Method. One-hundred sixty-seven patients had PJI after total knee arthroplasty. Plastic surgical reconstruction of a concomitant perigenicular soft-tissue defect was indicated in 49 patients. Of these, seven presented with extensor apparatus deficiency. Results. One patient underwent primary arthrodesis and six patients underwent autologous reconstruction of the extensor apparatus. The principle to reconstruct missing tissue ‘like with like’ was thereby favoured: Two patients with a wide soft-tissue defect received a free anterolateral thigh flap with fascia lata; one patient with a smaller soft-tissue defect received a free sensate, extended lateral arm flap with triceps tendon; and three patients received a pedicled medial sural artery perforator gastrocnemius flap, of which one with Achilles tendon. Despite good functional results 1 year later, long-term follow-up revealed that two patients had to undergo knee arthrodesis because of recurrent infection and one patient was lost to follow-up. In parts, results have been published under doi: 10.7150/jbji.47018. Conclusions. A treatment concept and its rationale, based on a single-centre experience, is presented. It differentiates between various types of soft-tissue defects and shows reconstructive options following the concept to reconstruct ‘like with like’. Despite good results 1 year postoperatively, PJI of the knee with extensor apparatus deficiency remains a dreaded combination with a poor long-term outcome


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_6 | Pages 34 - 34
1 May 2021
Katsura C Bates J Barlow G Chuo CB
Full Access

Introduction. Osteomyelitis (OM) is a challenging condition to diagnose and treat. The multidisciplinary team (MDT) approach is used in managing complex diseases such as cancer and diabetes. The Hull Regional Bone Infection MDT team was established to provide coordinated care for patients suspected to have OM. This study reviews the orthoplastic treatment and outcomes of patients with non-periprosthetic OM. Materials and Methods. Retrospective review of patients presenting to the MDT team who had orthoplastic intervention with debridement and flap coverage between 1/6/2014 - 30/11/2018. We describe our MDT approach of assessment, planning for surgical intervention and antibiotic protocol. Data was obtained from electronic and paper patient records, and PACS. Results. Twenty-nine patients were identified (75.9% male). Mean age was 52.7 (23–82). Median duration of symptoms at surgery was 10 months (IQR 4.0–34.3). Cierny-Mader (CM) Host Type B. (L). (41.4%), type B. (S). (34.5%), and type B. (S+L). (17.2%). Twenty-four patients (82.8%) were CM anatomical class IV. Twenty-four patients (82.8%) had single-stage surgical treatment. Twenty-one patients received 23 free flaps. Anterolateral thigh flap (9/23) and gracilis muscle flap (7/23) were most commonly used. Tibialis anterior flap was the most commonly used local flap. Stimulan was used in 65.5%. Staphylococcus aureus was seen in 60% of patients. Mean follow-up time was 21 months (1–62). There were 2 (6.9%) OM recurrence. Both patients were CM anatomical class IV. Conclusions. Our study showed that our MDT management of patients with OM can achieve a low recurrence rate despite a high proportion of patients with severe OM. We recommend considering an MDT approach for these complex OM patients


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_3 | Pages 20 - 20
1 Feb 2017
Athwal K El Daou H Lord B Davies A Manning W Rodriguez-Y-Baena F Deehan D Amis A
Full Access

Introduction. There is little information available to surgeons regarding how the lateral soft-tissue structures prevent instability in knees implanted with total knee arthroplasty (TKA). The aim of this study was to quantify the lateral soft-tissue contributions to stability following cruciate retaining (CR) TKA. Methods. Nine cadaveric knees with CR TKA implants (PFC Sigma; DePuy Synthes Joint Reconstruction) were tested in a robotic system (Fig. 1) at full extension, 30°, 60°, and 90° flexion angles. ±90 N anterior-posterior force, ±8 Nm varus-valgus and ±5 Nm internal-external torque were applied at each flexion angle. The anterolateral structures (ALS, including the iliotibial band, anterolateral ligament and anterolateral capsule), the lateral collateral ligament (LCL), the popliteus tendon complex (Pop T) and the posterior cruciate ligament (PCL) were then sequentially transected. After each transection the kinematics obtained from the original loads were replayed, and the decrease in force / moment equated to the relative contributions of each soft-tissue to stabilising the applied loads. Results. In the CR TKA knee, the LCL was found to be the primary restraint to varus laxity (Fig. 2, an average 56% across all flexion angles), and was significant in internal-external rotational stability (28% and 26% respectively) and anterior drawer (16%). The ALS restrained 25% of internal rotation (Fig. 3), whilst the PCL was significant in posterior drawer only at 60° and 90° flexion. The Pop T was not found to be significant in any tests. Conclusion. This study has for the first time delineated the relative contributions of lateral structures to stability in the implanted knee. It was confirmed that the LCL is the major lateral structure in CR TKA stability throughout the arc of flexion. In the event of LCL deficiency, stability of the knee may only be restored by either changing to a more constrained implant or performing a reconstruction of the ligament. Furthermore, care should be taken when releasing the LCL to correct a valgus deformity as it may result in a combined rotational laxity pattern that cannot be overcome by the other passive lateral structures or the PCL. For figures, please contact authors directly