Introduction. Numerous types of graft can be used for revision of
Introduction.
Introduction.
Introduction. Anterior tibial translation (ATT) is assessed in the acutely injured knee to investigate for ligamentous injury and rotational laxity. Specifically, there is a growing recognition of the significance of anterior medial rotary laxity (AMRI) as a crucial element in assessing knee stability.
Though knee osteoarthritis (OA) is diagnosed and monitored radiographically, full thickness cartilage loss (FTCL) has rarely been correlated with radiographic classification. This study aims to analyse which classification system correlates best with FTCL and assessing their reliability. Prospective study of 300 consecutive patients undergoing total knee arthroplasty (TKA) for OA. Two blinded examiners independently graded preoperative radiographs using 5 systems: Kellgren-Lawrence (KL); International Knee Documentation Committee (IKDC); Fairbank; Brandt; and Ahlback. Interobserver agreement was assessed using the intraclass correlation coefficient. Intraoperatively,
ACL (anterior cruciate ligament) partial tears include various types of lesions, and an high rate of these lesions evolve into complete tears. Most of the techniques described in literature for the surgical treatment of chronic partial ACL tears, don't spare the intact portion of the ligament. Aim of this study was to perform a prospective analysis of the results obtained by augmentation surgery using gracilis and semitendinosus tendons to treat partial sub-acute lesions of the ACL. This technique requires an “over the top” femoral passage, which enables salvage and strengthening of the intact bundle of ACL. The study included 97 patients treated consecutively at our Institute from 1993 to 2004 with a mean injury-surgery interval of 23 weeks (12–39). Patients were followed up by clinical and instrumental assessment criteria at 3 months, 1 year and 5 years after surgery. Clinical assessment was performed with the IKDC form. Subjective and functional parameters were assessed by the Tegner activity scale. Instrumental evaluation was done using the KT-2000 instrument: the 30 pound passive test and the manual maximum displacement test were performed. We obtained good to excellent results in 95.9% of cases. We didn't observed recurrences in ligamentous laxity. We believe that the described technique has the advantage of being little invasive, compatible with the
We reviewed all patients that suffered a deep infection following
AIM. Failure of a primary
INTRODUCTION. Patellar tendon (PT) autograft is an excellent choice repairing
Introduction. Unicompartmental knee arthroplasty (UKA) in patients with isolated medial osteoarthritis of the knee is nowadays a standard procedure with good results, especially with the minimally-invasive approach. However, the survival rate of the unicompartmental knee prostheses is inferior to that of total knee prostheses. Therefore, further studying of UKA is still necessary. In most mobile bearing designs the femoral component has a spherical surface and therefore its positioning is not crucial. The role of the tibial slope in UKA has not been investigated so far. The manufacturers recommend tibial slopes with values between 10° positive slope and 5° negative slope. Most surgeons try to reconstruct the anatomical slope with a high failure by measuring the slope on x-rays. The aim of this study was to investigate the influence of the tibial slope on the wear rate of a medial UKA. Materials and methods. In vitro wear simulation of medial mobile bearing unicompartmental knee prosthesis with a spherical femoral surface (Univation ®) was performed with a customized four-station servo-hydraulic knee wear simulator (EndoLab GmbH, Thansau, Germany) reproducing exactly the walking cycle as specified in ISO 14243–1:2002(E). The tibial tray was inserted with 2 different medial tibial slopes: 0°, 8° (n=3 for each group). The lateral tibial slope of the space-holder was not changed (0° for every group). We performed a total of 5 million cycles for every different slope, the gravimetric wear rate was determined gravimetrically using an analytical balance every 500 000 cycles according to the ISO 14243–2. Results. The wear rate in the 0° slope group was 3.46±0.59 mg/million cycles, and in the 8° slope group it was 0.99±0.42 mg/million cycles. The difference between the 0° tibial slope group and the 8° tibial slope group was highly significant (p<0.01, alternate t-test). Discussion. An increase of the tibial slope leads to a reduced wear rate in a mobile bearing UKA. Therefore, a higher tibial slope should be recommended for mobile bearing UKA. However, the influence on the ligaments has to be considered as a higher tibial slope leads to an increased strain on the
Introduction. The options for the treatment of the young active patient with unicompartmental symptomatic osteoarthritis and pre-existing
Tibial plateau fractures are serious injuries about the knee that have the potential to affect patients’ long-term function. To our knowledge, this is the first study to use patient-reported outcomes (PROs) with a musculoskeletal focus to assess the long-term outcome, as compared to a short-term outcome baseline, of tibial plateau fractures treated using modern techniques. In total, 102 patients who sustained a displaced tibial plateau fracture and underwent operative repair by one of three orthopaedic traumatologists at a large, academic medical centre and had a minimum of five-year follow-up were identified. Breakdown of patients by Schatzker classification is as follows: two (1.9%) Schatzker I, 54 (50.9%) Schatzker II, two (1.9%) Schatzker III, 13 (12.3%) Schatzker IV, nine (8.5%) Schatzker V, and 26 (24.5%) Schatzker VI. Follow-up data obtained included: Visual Analogue Scale (VAS) or Numeric Rating Scale (NRS) pain scores, Short Musculoskeletal Functional Assessment (SMFA), and knee range of movement (ROM). Data at latest follow-up were then compared to 12-month data using a paired Aims
Methods
The aim of this study was to compare the incidence of anterior knee pain after antegrade tibial nailing using suprapatellar and infrapatellar surgical approaches A total of 95 patients with a tibial fracture requiring an intramedullary nail were randomized to treatment using a supra- or infrapatellar approach. Anterior knee pain was assessed at four and six months, and one year postoperatively, using the Aberdeen Weightbearing Test – Knee (AWT-K) score and a visual analogue scale (VAS) score for pain. The AWT-K is an objective patient-reported outcome measure that uses weight transmitted through the knee when kneeling as a surrogate for anterior knee pain.Aims
Patients and Methods
Intramedullary tibial nailing was performed in ten paired cadavers and the insertion of a medial-to-lateral proximal oblique locking screw was simulated in each specimen. Anatomical dissection was undertaken to determine the relationship of the common peroneal nerve to the cross-screw. The common peroneal nerve was contacted directly in four tibiae and the cross-screw was a mean of 2.6 mm (1.0 to 10.7) away from the nerve in the remaining 16. Iatrogenic injury to the common peroneal nerve by medial-to-lateral proximal oblique locking screws is therefore a significant risk during tibial nailing.