Advertisement for orthosearch.org.uk
Results 1 - 20 of 196
Results per page:
Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 52 - 52
1 Sep 2012
Van Der Linden H Van Der Zwaag H Konijn L Van Der Steenhoven T Van Der Heide H Nelissen R
Full Access

Introduction. Malrotation following total knee replacement is directly related to poor outcome. The knowledge of proximal and distal rotational axes and angles of the femur is therefore of high importance. The aim of the study was to determine whether the most used proximal and distal femoral angles; femoral anteversion angle (FAA) and posterior condylar angle (PCA) were different within individuals, between right, left and gender. As well, we studied whether the “inferior condylar angle” is correlated to the PCA and therefore useful in determining the rotation of the distal femur. Material and Methods. From 36 cadavers the femora were obtained and after removing the soft tissue a Computed Tomography (CT) scan was made. Three angles were measured: (i) the FAA between femoral columnar line (FHNL) and posterior condylar line (PCL), (ii) the PCA between anatomical transepicondylar line (TEL) and PCL, (iii) the inferior condylar angle (ICA) between the TEL and inferior condylar line (ICL). Statistical analysis of comparative relationships between the different angles was examined by calculating correlation coefficients and a paired t-test. Results. The mean FAA, PCA and ICA for the whole group were respectively 12.0 degrees (range 0.2–31.6, SD 8.3, 95% CI 9.6–14.4), 4.8 degrees (range 0.9–9.6, SD 2.3, 95% CI 4.1–5.4) and 4.5 degrees (range 0.1–9.8, SD 2.1, 95% CI 3.9–5.1). A strong correlation of the FAA was found within the total group and left versus right (r = 0.82; p = 0.00). A weaker relationship was found for the total group of the PCA measurements (r = 0.59; p = 0.00). When FAA compared to the PCA subdivided in only sexes, there is a weak correlation for the female group (r = 0.54; p = 0.00) Despite the small mean difference of the mean ICA and PCA, there was no correlation between these two angles. Conclusion. Considering the weak correlation of the FAA and PCA within the group but also individuals, the importance of development of more individual approaches for determining the optimal rotation of the components in total knee surgery is essential. As a result, one should be aware that the widely used, current guidelines for knee rotation of 3 degrees of external rotation in placing total knee arthroplasties shows variation between individuals. A more individual approach in total knee arthroplasty seems essential for future knee prosthesis implantations


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 34 - 34
1 Sep 2012
Friedl W Singh S Anastasiu A
Full Access

Distal radius fractures are typical and frequent fracture of elderly woman with reduced bone density. Thus implant fixation is more difficult. Dorsal and radial comminution are frequent in these patients and so reduction and angle stable osteosynthesis needed. The angle stable plate, often also multidirectional is today the most common stabilisation device. Because of the introduction of bulky and bended implants as the Micronail or Targon DR wich require difficult opening of the bone with awles we decided to test the XS radius nail witch is a 4,5mm or 3,5mm straight nail and witch is introduced after guide wire placement and over drilling with a canulated drill of the same diameter. It is locked parallel to the joint in 3 different directions with angular stability with threaded wires. Methods 16 radius sawbones were osteotomised corresponding to a A3 Fracture and stabilised with a angle stable plate (8) and XS nail (8). 1000 alternating load cycles from 20–200N were performed and the deformation was registered. Also a FE analysis with the MSC Patran/Marc softwere were performed. Also the calculated deformation in the FE study was 20% lower. Also deformation amplitude was lower with 0.31mm compared to 0.42mm in the plate group. The differences however were not significant. Both devices show good biomechanical results. The XS nail has the advantage of mainly intraosseus position, simple operation technique with introduction over a guide wire from the proc. Styloideus radii and over drilling with a canulated drill of the same size. The exposure of the N rad. superf. must be performed. First clinical evaluation is presented. Due to the results we developed a anatomically adapted XS radius nail. The results of the first 100 patients are presented. Conclusions. Both angular stable plate and XSR nail can be used in unstable distal radius fracture fixation. The mainly intraosseus position of the nail and saving of the pronator quadratus as well as lower deformation are in favour of the XSR nail. However frontal plane fractures and very comminuted fractures are better treated with a multidirectional locking plate due to technical reasones so that we use the XSR nail mainly in A3 and C1 fractures


Aims. The aim of this study was to evaluate the outcomes of a salvage procedure using a 95° angled blade plate for failed osteosynthesis of atypical subtrochanteric femoral fractures associated with the long-term use of bisphosphonates. These were compared with those for failed osteosynthesis of subtrochanteric fractures not associated with bisphosphonate treatment. Patients and Methods. Between October 2008 and July 2016, 14 patients with failed osteosynthesis of an atypical subtrochanteric femoral fracture were treated with a blade plate (atypical group). Their mean age was 67.8 years (60 to 74); all were female. During the same period, 21 patients with failed osteosynthesis of a typical subtrochanteric fracture underwent restabilization using a blade plate (typical group). Outcome variables included the time of union, postoperative complications, Harris Hip Score, and Sanders functional rating scale. Results. In the atypical group, union was achieved in 12 patients (85.7%) at a mean of 8.4 months (4 to 12). The mean follow-up was 31.2 months (12 to 92) The plate broke in one patient requiring further stabilization with a longer plate and strut-allograft. Another patient with failure of fixation and varus angulation at the fracture site declined further surgery. In the typical group, union was achieved in 18 patients (85.7%) at a mean of 7.9 months (4 to 12). There was no difference in the mean Harris Hip Score between the two groups (83.1 points vs 86.8 points; p = 0.522) at the time of final follow-up. Sanders functional rating scores were good or excellent in 78.6% of the atypical group and in 81.0% of the typical group. Conclusion. The 95° angled blade plate was shown to be an effective fixation modality for nonunion of atypical subtrochanteric fractures with a high rate of union and functional improvement, comparable to those after fractures not associated with bisphosphonate treatment. Cite this article: Bone Joint J 2018;100-B:1511–17


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 400 - 400
1 Sep 2012
Odri G Fraquet N Isnard J Redon H Frioux R Gouin F
Full Access

Cam type femoroacetabular impingement (FAI) is due to an aspheric femoral head, which is best quantified by the alpha angle described on MRI and CT-scan. Radiographic measurement of the alpha angle is not well codified and studies from the literature cannot conclude on the best view to measure it. Most authors also describe a mixed type FAI which associates an aspheric femoral head with an excessive anterior acetabular coverage of the femoral head. Anterior center edge (ACE) angle has been described on the false profile view to measure anterior acetabular coverage in hip dysplasia and has never been evaluated in FAI. In this study, we developed a new lateral hip view which associates a lateral view of the femoral neck and a false profile view of the acétabulum, which we called profile view in impingement position (PVIP). Twenty six patients operated for FAI had CT-scan, the PVIP and the false profile view of one or two hips according to pain. A control group of 19 patients who did not suffer from the hip had the PVIP. Alpha angles were measured twice on 17 CT scan of FAI patients by two observers and compared with the alpha angles measured on the corresponding hip PVIP by a correlation analysis. Alpha angles were measured twice on 45 PVIP in FAI patient and on 19 PVIP in the control group by three observers. ACE angles were measured once on 15 PVIP and on 15 false profile views. Means were compared by two tail paired t-tests, intra- and inter-observer reliability were measured by intraclass correlation coefficient. Mean alpha angle on CT scan was 65.8° and 65.6° for observers 1 and 2 respectively (p>0.05). It was 63.6° and 64.3° on the PVIP (p>0.05). No significant difference was found between CT scan and radiographic measurements, and Pearson's correlation coefficients were good at 0.74 and 0.8. ICC was 0.86 for inter-rater reliability, and 0.91 for intra-rater reliability for CT-scan alpha angle measures. ICC for PVIP measures varied from 0.82 to 0.9 for intra-rater reliability and from 0.6 to 0.9 for inter-rater reliability. Mean alpha angle measured on PVIP in FAI patients was 63.3° and was 44.9° in control subjects and the difference was significant (p<0.001) for the three observers. None of the FAI patients and 88% of the control subjects had an alpha angle < 50°. Mean ACE angle was 26.8° on PVIP and 32.8° on the false profile view, the difference was significant (p=0.015), and the Pearson's correlation coefficient was moderate (r=0.58). The PVIP is a reliable radiographic view to measure the alpha angle. It allows a good quantification of the alpha angle comparable to CT-scan measurements and permits to differentiate patients from control subjects. PVIP is not a good view to quantify anterior edge angle probably because of acetabular retroversion due to the hip flexion needed in this view. Mean ACE angle measured on the false profile view in FAI patient was comparable to ACE angle in general population reported in the literature


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 9 | Pages 1259 - 1264
1 Sep 2011
Wähnert D Windolf M Brianza S Rothstock S Radtke R Brighenti V Schwieger K

We investigated the static and cyclical strength of parallel and angulated locking plate screws using rigid polyurethane foam (0.32 g/cm. 3. ) and bovine cancellous bone blocks. Custom-made stainless steel plates with two conically threaded screw holes with different angulations (parallel, 10° and 20° divergent) and 5 mm self-tapping locking screws underwent pull-out and cyclical pull and bending tests. The bovine cancellous blocks were only subjected to static pull-out testing. We also performed finite element analysis for the static pull-out test of the parallel and 20° configurations. In both the foam model and the bovine cancellous bone we found the significantly highest pull-out force for the parallel constructs. In the finite element analysis there was a 47% more damage in the 20° divergent constructs than in the parallel configuration. Under cyclical loading, the mean number of cycles to failure was significantly higher for the parallel group, followed by the 10° and 20° divergent configurations. In our laboratory setting we clearly showed the biomechanical disadvantage of a diverging locking screw angle under static and cyclical loading


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 369 - 369
1 Sep 2012
Rodriguez Vega V Cecilia D Suarez L Jorge A Auñon I Rojo M Blanco D Guimera V Bravo B Garcia L Resines C
Full Access

Introduction. Distal radius fractures are one of the most common injuries attended in hospitals. Throughout the years the treatment has change from simple cast to ORIF. Objectives. To compare the functional and radiographic results in the treatment of the distal intrarticular radial fractures treated by volar buttress plate (T plate AO® Synthes, Oberdorf, Suiza) and fixed volar angle locking plate (DVR® Depuy, Warsaw, Indiana, USA). Material and Methods. We performed a comparative retrospective study between two series of patients treated by fixed volar angle locking plate (40 patients) or volar buttress plate (36 patients). Distal radius fractures were classified by the AO/ASIF Müller classification after X-ray study in two views (Anteroposterios and lateral views), surgical treatment was indicated by the type of fracture (unstable fractures) and open fractures. Demographic information was gathered, injury mechanism and postoperatory complications. The minimal follow-up was 10 months. We performed clinical and radiographic evaluations before surgery, postoperatory, to 3 months and at the end of the follow-up (Palmar tilt, radial inclination, radial height and the radioulnar index were measured). Lidström's and Quick Dash scale, by means of telephonic survey, were used for the functional evaluation. Results. The time from fracture to surgery was on average 3.74 days in the group of DVR ® plates and 1.69 days for the group treated with T buttress plates. Henry's approach was realized in every case and the average time spent in surgery was 74 minutes for patients treated with T buttress plate and 80 minutes for patients treated with plate DVR®. In some cases K wires had to be used in 9 cases in the DVR® group and 7 in the other group. DVR® group obtained better results in radiological evaluation except in the radial inclination. In the Quick Dash scale, conducted a telephone survey, the average for the DVR® group was 26.40 (CI: 13.6 to 81.8) and 33.37 (CI: 10.2–90) for the group of T buttress plate (p=0.055). Conclusion. The potential advantages of ORIF in the distal radius fractures are low complication rate, stable subchondral fixation and early active movement of the wrist in the postoperative period. The disadvantages are a high cost, greater complexity and surgical exposure. Locking plates were designed to prevent postoperative collapse of the fracture also allows a better fix system in osteoporotic bone. Both types of plates obtained good results radiological and functional at the end of follow-up but we have obtained better results in the patients treated with locking plates


Background:. Acute deformity correction with the help of osteotomies and stabilisation with intramedullary (IM) nail is a recognised technique. We present our case series of long bong deformity correction using an innovative technique that aids accurate correction after osteotomy and insertion of IM nail. Technique:. On preoperative measurements the distance of the joint surface from the point of intersection of the joint orientation angle with the convex cortex and also its distance from apex of deformity were noted. These distances were reproduced intraoperatively and guide pin was inserted towards premeasured point in the convex cortex. Osteotomy was performed and appropriate sized locked IM nail inserted with the help of temporary blocking screws, resulting in the correction of deformities. Method:. Retrospective review of case notes and radiographs was performed of five patients who underwent long bone deformity correction using this technique. Average age of patients was 15.2yrs. Underlying diagnosis were hypophosphataemic rickets, growth arrests and juvenile osteoporosis. Results:. Length of follow up was from 6 to 24 months. All osteotomies had healed at an average of 46 days. Of the eleven bone segments, nine had normal alignment (within 2.5° of normal or contralateral side). In the other two bone segments the alignment was between 2.5° and 5°. Blocking screws were not used in both these cases. Conclusions:. This is a simple technique of deformity correction. Keys to improve accuracy of correction are preoperative planning, intraoperative blocking screws and oblique osteotomies to accommodate translation


The Bone & Joint Journal
Vol. 95-B, Issue 6 | Pages 815 - 819
1 Jun 2013
Yadav V Khare GN Singh S Kumaraswamy V Sharma N Rai AK Ramaswamy AG Sharma H

Both conservative and operative forms of treatment have been recommended for patients with a ‘floating shoulder’. We compared the results of conservative and operative treatment in 25 patients with this injury and investigated the use of the glenopolar angle (GPA) as an indicator of the functional outcome. A total of 13 patients (ten male and three female; mean age 32.5 years (24.7 to 40.4)) were treated conservatively and 12 patients (ten male and two female; mean age 33.67 years (24.6 to 42.7)) were treated operatively by fixation of the clavicular fracture alone. Outcome was assessed using the Herscovici score, which was also related to changes in the GPA at one year post-operatively.

The mean Herscovici score was significantly better three months and two years after the injury in the operative group (p < 0.001 and p = 0.003, respectively). There was a negative correlation between the change in GPA and the Herscovici score at two years follow-up in both the conservative and operative groups, but neither were statistically significant (r = -0.295 and r = -0.19, respectively). There was a significant difference between the pre- and post-operative GPA in the operative group (p = 0.017).

When compared with conservative treatment, fixation of the clavicle alone gives better results in the treatment of patients with a floating shoulder. The GPA changes significantly with fixation of clavicle alone but there is no significant correlation between the pre-injury GPA and the final clinical outcome in these patients.

Cite this article: Bone Joint J 2013;95-B:815–19.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 555 - 555
1 Sep 2012
Starks I Frost A Wall P Lim J
Full Access

The management of pelvic fractures remains a challenging problem for orthopaedic surgeons. The prompt recognition of unstable fracture patterns is important in reducing mortality and morbidity. It is perceived wisdom that a fracture of the transverse process of L5 is a predictor of pelvic fracture instability. There is a paucity of evidence in the literature to support this belief. The aim of our study was to determine if a fracture of the transverse process of L5 was a predictor of pelvic fracture instability.

The Hospital Trauma database was reviewed. Between 2006 and 2009, 65 pelvic fractures were identified. They were classified according to the Burgess and Young classification. There were 37 stable and 28 unstable fractures. 14 patients had an associated fracture of the transverse process of L5; 9 were associated with an unstable fracture pattern. The odds ratio was 3; the relative risk 1.7.

A fracture of the transverse process of L5 is associated with an increased risk of pelvic fracture instability. Its presence should alert the attending physicians to the possibility of an unstable injury.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 168 - 168
1 Sep 2012
Von Rueden C Trapp O Hierholzer C Prohaska S Bräun K Wurm S Buehren V
Full Access

Background

For the treatment of proximal humeral fractures two major therapeutic principles can be employed: Intramedullary nailing (PHN) or locking plate osteosynthesis. Aim of this study was to evaluate and compare clinical and radiological long-term outcome of proximal humeral fracture stabilization using PHN or angular stable plating. In addition, we discussed advantages and disadvantages of both techniques and aimed at establishing criteria which operative technique should preferentially be utilized for selected fracture configurations.

Materials and Methods

In a prospective study between 2003 and 2010 we analyzed 72 patients with proximal humeral fracture who had been treated by PHN (44 patients) or angular stable plating (28 patients) in a European Level 1 Trauma Center. In the two cohort groups the following epidemiologic data was found. 46 patients were women, and 26 men with a mean age of 60.6 years (range 18–91). Follow-up was performed 38–82 months after accident, on average. Mechanism of injury was fall in 59, motor cycle accident in 4, bike accident in 8 patients, and fall from horse in 1 patient. Duration time between accident and operation was 2.8 days on average. Osteoporosis was previously known in 20 out of all evaluated patients (plate: 7/28; nail: 13/44). Fractures were classified using the Neer classification and Binary description system: There were 35 3-part fractures (PHN: 26; plate: 9) and 37 4-part fractures (PHN: 18; plate: 19), respectively. Functional and radiological outcome was assessed in a range of 38–82 months after trauma using Constant Score.


The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1348 - 1360
1 Nov 2024
Spek RWA Smith WJ Sverdlov M Broos S Zhao Y Liao Z Verjans JW Prijs J To M Åberg H Chiri W IJpma FFA Jadav B White J Bain GI Jutte PC van den Bekerom MPJ Jaarsma RL Doornberg JN

Aims. The purpose of this study was to develop a convolutional neural network (CNN) for fracture detection, classification, and identification of greater tuberosity displacement ≥ 1 cm, neck-shaft angle (NSA) ≤ 100°, shaft translation, and articular fracture involvement, on plain radiographs. Methods. The CNN was trained and tested on radiographs sourced from 11 hospitals in Australia and externally validated on radiographs from the Netherlands. Each radiograph was paired with corresponding CT scans to serve as the reference standard based on dual independent evaluation by trained researchers and attending orthopaedic surgeons. Presence of a fracture, classification (non- to minimally displaced; two-part, multipart, and glenohumeral dislocation), and four characteristics were determined on 2D and 3D CT scans and subsequently allocated to each series of radiographs. Fracture characteristics included greater tuberosity displacement ≥ 1 cm, NSA ≤ 100°, shaft translation (0% to < 75%, 75% to 95%, > 95%), and the extent of articular involvement (0% to < 15%, 15% to 35%, or > 35%). Results. For detection and classification, the algorithm was trained on 1,709 radiographs (n = 803), tested on 567 radiographs (n = 244), and subsequently externally validated on 535 radiographs (n = 227). For characterization, healthy shoulders and glenohumeral dislocation were excluded. The overall accuracy for fracture detection was 94% (area under the receiver operating characteristic curve (AUC) = 0.98) and for classification 78% (AUC 0.68 to 0.93). Accuracy to detect greater tuberosity fracture displacement ≥ 1 cm was 35.0% (AUC 0.57). The CNN did not recognize NSAs ≤ 100° (AUC 0.42), nor fractures with ≥ 75% shaft translation (AUC 0.51 to 0.53), or with ≥ 15% articular involvement (AUC 0.48 to 0.49). For all objectives, the model’s performance on the external dataset showed similar accuracy levels. Conclusion. CNNs proficiently rule out proximal humerus fractures on plain radiographs. Despite rigorous training methodology based on CT imaging with multi-rater consensus to serve as the reference standard, artificial intelligence-driven classification is insufficient for clinical implementation. The CNN exhibited poor diagnostic ability to detect greater tuberosity displacement ≥ 1 cm and failed to identify NSAs ≤ 100°, shaft translations, or articular fractures. Cite this article: Bone Joint J 2024;106-B(11):1348–1360


The Bone & Joint Journal
Vol. 103-B, Issue 11 | Pages 1648 - 1655
1 Nov 2021
Jeong S Hwang K Oh C Kim J Sohn OJ Kim JW Cho Y Park KC

Aims. The incidence of atypical femoral fractures (AFFs) continues to increase. However, there are currently few long-term studies on the complications of AFFs and factors affecting them. Therefore, we attempted to investigate the outcomes, complications, and risk factors for complication through mid-term follow-up of more than three years. Methods. From January 2003 to January 2016, 305 patients who underwent surgery for AFFs at six hospitals were enrolled. After exclusion, a total of 147 patients were included with a mean age of 71.6 years (48 to 89) and 146 of whom were female. We retrospectively evaluated medical records, and reviewed radiographs to investigate the fracture site, femur bowing angle, presence of delayed union or nonunion, contralateral AFFs, and peri-implant fracture. A statistical analysis was performed to identify the significance of associated factors. Results. The mean follow-up period was 70.2 months (36 to 191). There were 146 AFFs (99.3%) in female patients and the mean age was 71.6 years (48 to 89). The AFFs were located in the subtrochanter and shaft in 52 cases (35.4%) and 95 (64.6%), respectively. The preoperative mean anterior/lateral femoral bowing angles were 10.5° (SD 5.7°)/6.1° (SD 6.2°). The postoperative mean anterior/lateral bowing values were changed by 8.7° (SD 5.4°)/4.6° (SD 5.9°). Bisphosphonates had been used contemporarily in 115 AFFs (78.2%) for a mean of 52.4 months (1 to 204; SD 45.5) preoperatively. Nailing was performed in 133 AFFs (90.5%), and union was obtained at a mean of 23.6 weeks (7 to 85). Delayed union occurred in 41 (27.9%), and nonunion occurred in 13 (8.8%). Contralateral AFF occurred in 79 patients (53.7%), and the use of a bisphosphonate significantly influenced the occurrence of contralateral AFFs (p = 0.019). Peri-implant fractures occurred in a total of 13 patients (8.8%), and a significant increase was observed in cases with plating (p = 0.021) and high grade of postoperative anterolateral bowing (p = 0.044). Conclusion. The use of a bisphosphonate was found to be a risk factor for contralateral AFF, and high-grade postoperative anterolateral bowing and plate fixation significantly increased the occurrence of peri-implant fractures. Long-term follow-up studies on the bilaterality of AFFs and peri-implant fractures are warranted. Cite this article: Bone Joint J 2021;103-B(11):1648–1655


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_14 | Pages 3 - 3
10 Oct 2023
Verma S Malaviya S Barker S
Full Access

Technological advancements in orthopaedic surgery have mainly focused on increasing precision during the operation however, there have been few developments in post-operative physiotherapy. We have developed a computer vision program using machine learning that can virtually measure the range of movement of a joint to track progress after surgery. This data can be used by physiotherapists to change patients’ exercise regimes with more objectively and help patients visualise the progress that they have made. In this study, we tested our program's reliability and validity to find a benchmark for future use on patients. We compared 150 shoulder joint angles, measured using a goniometer, and those calculated by our program called ArmTracking in a group of 10 participants (5 males and 5 females). Reliability was tested using adjusted R squared and validity was tested using 95% limits of agreement. Our clinically acceptable limit of agreement was ± 10° for ArmTracking to be used interchangeably with goniometry. ArmTracking showed excellent overall reliability of 97.1% when all shoulder movements were combined but there were lower scores for some movements like shoulder extension at 75.8%. There was moderate validity shown when all shoulder movements were combined at 9.6° overestimation and 18.3° underestimation. Computer vision programs have a great potential to be used in telerehabilitation to collect useful information as patients carry out prescribed exercises at home. However, they need to be trained well for precise joint detections to reduce the range of errors in readings


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_5 | Pages 10 - 10
13 Mar 2023
Rankin C Coleman S Robinson P Murray I Clement N
Full Access

We aim to determine the differences in lower limb joint kinematics during the golf swing of patients who had undergone Total Knee Arthroplasty (TKA) and a control group of native knee golfers. A case-control study was undertaken with ten golfers who had undergone TKA (cruciate retaining single radius implant) and five age and matched golfers with native knees. Each golfer performed five swings with a driver whilst being recorded at 200Hz by a ten-camera motion capture system. Knee and hip three-dimensional joint angles (JA) and joint angular velocities (JAV) were calculated and statistically compared between the groups at six swing events. The only significant differences in knee joint kinematics between TKA and control groups was a lower external rotation JA in the left knee during the backswing (p=0.010). There was no significant difference in knee JAV between the groups. Both hips demonstrated significantly (p=0.023 for left and p=0.037 for right) lower flexion in the TKA group during the takeaway swing event, and there was lower internal rotation in the backswing and greater external rotation in the downswing of the right hip. There was also slower left hip extension JAV in the downswing. Normal knee kinematics were observed during the golf swing following TKA, with the exception of reduced external rotation in the left knee during the back swing and the right during the down swing. The differences demonstrated in the hip motion indicate that they may make compensatory movements to adjust to the reduced external rotation demonstrated in the knee


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_12 | Pages 9 - 9
1 Oct 2021
Scott-Watson M Adams S Dixon M Garcia-Martinez S Johnston M Adams C
Full Access

Success treating AIS with bracing is related to time worn and scoliosis severity. Temperature monitoring can help patients comply with their orthotic prescription. Routinely collected temperature data from the start of first brace treatment was reviewed for 14 patients. All were female with an average age of 12.4 years (range 10.3–14.6) and average 49o Cobb angle (30–64). Our current service recommendation is brace wear for 20 hours a day. Patients complied with this prescription 38.0% of the time, with four patients averaging this or more. Average brace wear was 16.3 hours per day (3.5–22.2). There were 13 patients who had completed brace treatment. The majority had surgery (7/13; 54%) or were considering surgery (1/13; 8%). There were 5 who did not wish surgery at discharge (5/13; 38%); 1 achieved a 40o Cobb angle, with 4 larger (53o;53o;54o;68o). The Bracing in AIS Trial (BrAIST) study measured “success” as less than a 50o Cobb angle, so using this metric our cohort has had a single “success”. Temperature monitors allowed an analysis of when patients were achieving their brace wear. When comparing daywear (8am-8pm) to nightwear (8pm-8am), patients wore their brace an average of 7.6 hours a day (2.5–11.2) and 8.7 hours a night (0.4–11.5). We conclude the minority of our patients comply with our current 20 hour orthotic prescription. The “success” of brace treatment is lower than comparison studies despite higher average compliance but starting with a larger scoliosis. Brace wear is achieved during both the day and night


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_12 | Pages 10 - 10
1 Oct 2021
Zein A Elhalawany AS Ali M Cousins G
Full Access

Despite multiple published reviews, the optimum method of correction and stabilisation of Blount's disease remains controversial. The purpose of this study is to evaluate the clinical and radiological outcomes of acute correction of late-onset tibial vara by percutaneous proximal tibial osteotomy with circular external fixation using two simple rings. This technique was developed to minimise cost in a context of limited resources. This study was conducted between 2016 and 2020. We retrospectively reviewed the clinical notes and radiographs of 30 patients (32tibiae) who had correction of late-onset tibia by proximal tibial osteotomy and Ilizarov external fixator. All cases were followed up to 2 years. The mean proximal tibial angle was 65.7° (±7.8) preoperatively and 89.8° (±1.7) postoperatively. The mean mechanical axis deviation improved from 56.2 (±8.3) preoperatively to 2.8 (±1.6) mm postoperatively. The mean femoral-tibial shaft angle was changed from – 34.3° (±6.7) preoperatively to 5.7° (±2.8) after correction. Complications included overcorrection (9%) and pin tract infection (25%). At final follow up, all patients had full knee range of motion and normal function. All cases progressed to union and there were no cases of recurrence of deformity. This simple procedure provides secure fixation allowing early weight bearing and early return to function. It can be used in the context of health care systems with limited resources. It has a relatively low complication rate. Our results suggest that acute correction and simple circular frame fixation is an excellent treatment choice for cases of late-onset tibia vara, especially in severe deformities


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_7 | Pages 13 - 13
1 May 2021
Davies-Branch NR Oliver WM Davidson EK Duckworth AD Keating JF White TO
Full Access

The aim was to report operative complications, radiographic and patient-reported outcomes following lateral tibial plateau fracture fixation augmented with calcium phosphate cement (CPC). From 2007–2018, 187 patients (median age 57yrs [range 22–88], 63% female [n=118/187]) with a Schatzker II/III fracture were retrospectively identified. There were 103 (55%) ORIF and 84 (45%) percutaneous fixation procedures. Complications and radiographic outcomes were determined from outpatient records and radiographs. Long-term follow-up was via telephone interview. At a median of 6 months (range 0.1–138) postoperatively, complications included superficial peroneal nerve injury (0.5%, n=1/187), infection (6.4%, n=12/187), prominent metalwork (10.2%, n=19/187) and post-traumatic osteoarthritis (PTOA; 5.3%, n=10/187). The median postoperative medial proximal tibial angle was 89o (range 82–107) and posterior proximal tibial angle 82o (range 45–95). Three patients (1.6%) underwent debridement for infection and 27 (14.4%) required metalwork removal. Seven patients (4.2%) underwent total knee replacement for PTOA. Sixty percent of available patients (n=97/163) completed telephone follow-up at a median of 6yrs (range 1–13). The median Oxford Knee Score was 42 (range 3–48), Knee injury and Osteoarthritis Outcome Score 88 (range 10–100), EuroQol 5-Dimension score 0.812 (range −0.349–1.000) and Visual Analogue Scale 75 (range 10–100). There were no significant differences between ORIF and percutaneous fixation in patient-reported outcome (all p>0.05). Fixation augmented with CPC is safe and effective for lateral tibial plateau fractures, with a low complication rate and good long-term knee function and health-related quality of life. Percutaneous fixation offers a viable alternative to ORIF with no detriment to patient-reported outcome


The Bone & Joint Journal
Vol. 103-B, Issue 2 | Pages 286 - 293
1 Feb 2021
Park CH Yan H Park J

Aims. No randomized comparative study has compared the extensile lateral approach (ELA) and sinus tarsi approach (STA) for Sanders type 2 calcaneal fractures. This randomized comparative study was conducted to confirm whether the STA was prone to fewer wound complications than the ELA. Methods. Between August 2013 and August 2018, 64 patients with Sanders type 2 calcaneus fractures were randomly assigned to receive surgical treatment by the ELA (32 patients) and STA (32 patients). The primary outcome was development of wound complications. The secondary outcomes were postoperative complications, pain scored of a visual analogue scale (VAS), American Orthopaedic Foot and Ankle Society (AOFAS) score, 36-item Short Form health survey, operative duration, subtalar joint range of motion (ROM), Böhler’s angle and calcaneal width, and posterior facet reduction. Results. Although four patients (12.5%) in the ELA groups and none in the STA group experienced complications, the difference was not statistically significant (p = 0.113). VAS and AOFAS score were significantly better in the STA group than in the ELA group at six months (p = 0.017 and p = 0.021), but not at 12 months (p = 0.096 and p = 0.200) after surgery. The operation time was significantly shorter in the STA group than in the ELA group (p < 0.001). The subtalar joint ROM was significantly better in the STA group (p = 0.015). Assessment of the amount of postoperative reduction compared with the uninjured limb showed significant restoration of calcaneal width in the ELA group compared with that in the STA group (p < 0.001). Conclusion. The ELA group showed higher frequency of wound complications than the STA group for Sanders type 2 calcaneal fractures even though this was not statistically significant. Cite this article: Bone Joint J 2021;103-B(2):286–293


Aims

Ankle fracture fixation is commonly performed by junior trainees. Simulation training using cadavers may shorten the learning curve and result in a technically superior surgical performance.

Methods

We undertook a preliminary, pragmatic, single-blinded, multicentre, randomized controlled trial of cadaveric simulation versus standard training. Primary outcome was fracture reduction on postoperative radiographs.


Bone & Joint Open
Vol. 5, Issue 6 | Pages 457 - 463
2 Jun 2024
Coviello M Abate A Maccagnano G Ippolito F Nappi V Abbaticchio AM Caiaffa E Caiaffa V

Aims

Proximal femur fractures treatment can involve anterograde nailing with a single or double cephalic screw. An undesirable failure for this fixation is screw cut-out. In a single-screw nail, a tip-apex distance (TAD) greater than 25 mm has been associated with an increased risk of cut-out. The aim of the study was to examine the role of TAD as a risk factor in a cephalic double-screw nail.

Methods

A retrospective study was conducted on 112 patients treated for intertrochanteric femur fracture with a double proximal screw nail (Endovis BA2; EBA2) from January to September 2021. The analyzed variables were age, sex, BMI, comorbidities, fracture type, side, time of surgery, quality of reduction, pre-existing therapy with bisphosphonate for osteoporosis, screw placement in two different views, and TAD. The last follow-up was at 12 months. Logistic regression was used to study the potential factors of screw cut-out, and receiver operating characteristic curve to identify the threshold value.