Advertisement for orthosearch.org.uk
Results 1 - 20 of 133
Results per page:

Accurate evaluation of lower limb coronal alignment is essential for effective pre-operative planning of knee arthroplasty. Weightbearing hip-knee-ankle (HKA) radiographs are considered the gold standard. Mako SmartRobotics uses CT-based navigation to provide intra-operative data on lower limb coronal alignment during robotic assisted knee arthroplasty. This study aimed to compare the correlation between the two methods in assessing coronal plane alignment. Patients undergoing Mako partial (PKA) or total knee arthroplasty (TKA) were identified from our hospital database. The hospital PACS system was used to measure pre-operative coronal plane alignment on HKA radiographs. This data was correlated to the intraoperative deformity assessment during Mako PKA and TKA surgery. 443 consecutive Mako knee arthroplasties were performed between November 2019 and December 2021. Weightbearing HKA radiographs were done in 56% of cases. Data for intraoperative coronal plane alignment was available for 414 patients. 378 knees were aligned in varus, and 36 in valgus. Mean varus deformity was 7.46° (SD 3.89) on HKA vs 7.13° (SD 3.56) on Mako intraoperative assessment, with a moderate correlation (R= 0.50, p<0.0001). Intraoperative varus deformity of 0-4° correlated to HKA measured varus (within 3°) in 60% of cases, compared to 28% for 5-9°, 17% for 10-14°, and in no cases with >15° deformity. Mean valgus deformity was 6.44° (SD 4.68) on HKA vs 4.75° (SD 3.79) for Mako, with poor correlation (R=0.18, p=0.38). In this series, the correlation between weightbearing HKA radiographs and intraoperative alignment assessment using Mako SmartRobotics appears to be poor, with greater deformities having poorer correlation


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 22 - 22
1 Sep 2012
Boisrenoult P Berhouet J Beaufils P Frasca D Pujol N
Full Access

Introduction. Proper rotational alignment of the tibial component in total knee arthroplasty (TKA) could be achieved using several techniques. The self adjustment methodology allows the alignment of the tibial component under the femoral component after several flexion-extension movements. Our hypothesis was that this technique allowed a posterior tibial component alignment parallel to the femoral component posterior bicondylar axis. The aim of this study was to access this hypothesis using a post-operative CT-scan study. Materials and Methods. This prospective CT-scan study involved 94 TKA. Theses TKA were divided in two groups: group1: 50 knees with a pre-operative genu varum deformity (mean HKA: 172.2°), operated using a medial parapatellar approach, and group 2: 44 knees with a preoperative valgus deformity (mean HKA: 188.7°), operated using a lateral parapatellar approach. Four measures were done on each post-operative CT-scan: angle between anatomical transepicondylar axis and femoral component posterior bicondylar axis (FCPCA), angle between FCPCA and tibial component marginal posterior axis, angle between tibial component marginal posterior axis and bony tibial plateau marginal posterior axis (BTPMPA), angle between transepicondylar axis and tibial component marginal posterior axis. Each measure was repeated, after one month by the same independent observer. Statistical evaluation used non-parametric Wilcoxon–Mann–Whitney test to compare each group of measures, and intraobserver reproducibility was assessed using ANOVA test, with an error rate of 5%. Results. Intraobserver measurements were reproducible. Mean FCPCA was to 3,1° (SD:1,91) in group 1 and 4,7° (DS: 2,96) in group 2. Tibial component was positioned in external rotation in both groups, in relation to FCPCA: (group 1: mean angle: 0,7° (SD:4,45), group 2: mean angle: 0,9° (SD:4,53)) and in relation to BTPMPA: (group1: mean angle: 6,1° (SD: 5,85); group2: mean angle: 12,5° (SD: 8,6)). There was no statistical difference between these two groups. Tibial component was positioned in internal rotation in relation to anatomical transepicondylar axis: (Group1: mean angle: 1,9° (SD: 4,93); group 2: mean angle: 3° (SD: 4.38)). Discussion. By using the self adjustment technique, tibial component is aligned parallel to the femoral component regardless of the initial frontal deformity and the surgical approach. However, there was a difference in tibial component axis and BTPMPA, between the two groups. This difference should be explained by the difference in morphology of the tibial plateau bone in knee with genu valgum deformity. The self adjustment technique is a reliable method to obtain a proper rotational alignment of the tibial component in TKA


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_10 | Pages 10 - 10
1 Feb 2013
Howie D Love G Deakin A Kinninmonth A
Full Access

Component malalignment has long been implicated in poor implant survival in Total Knee Arthroplasty (TKA). Malalignment can occur in orientation of bony cuts, and in component cementation/implantation. Several systems exist to aid bony cut alignment (navigation, shape matching), but final implantation technique is common to all TKA. Correction of errors in bony cut alignment at cementation/implantation by surgeons has been described. Changes in alignment at this stage are likely to result in asymmetrical cement penetration, which is implicated in early failure. This study reviewed a consecutive series of 150 primary cemented TKAs using an imageless navigation system (aiming for neutral overall limb alignment). Deviation at implantation was calculated by comparing limb alignment recorded using the trial components with limb alignment recorded with the final implanted components, prior to closure. 136 patients (91%) had a final overall limb alignment within 2° of neutral. Three patients (2%) had a final overall limb alignment greater than 3° from neutral. Deviation occurring at implantation is shown in Figure 1 with deviations distributed around zero (mode 0, median 0.3, range −2 to +4,)


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_9 | Pages 13 - 13
1 May 2014
Arthur C Phillips J Toms A Mandalia V
Full Access

Kinematic alignment has increased in popularity over the last few years in an attempt to improve clinical outcomes following total knee arthroplasty (TKA). In our unit kinematic alignment has been used with patient-specific cutting guides as part of on-going clinical trials. We performed a retrospective analysis on all the TKA which had been planned to be implanted outside of the mechanical axis (0° ± 3°) based on pre-operative MRI scans and looked at their radiographic and clinical outcomes. We identified 21 knees which had been implanted as ‘planned outliers’. All had clinical and radiographic follow up to a mean 11.6 months post op. All had a standard long leg alignment radiograph performed at 6 weeks post op to confirm alignment. All patients had a good improvement in their Oxford Knee Scores with mean improvement from 23 pre-op to 42 at 1 year. Of our patients none had a poor clinical outcome due to the alignment of their TKA, 1 patient had a poor outcome because of a quadriceps rupture which occurred 4 months post-op. There were no post-operative radiographic abnormalities. In our unit kinematic alignment outside of the mechanical axis is not associated with an increased rate of short term complications


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 509 - 509
1 Sep 2012
Thomas G Hossain M Monk A Gill H Glyn-Jones S Andrew J Murray D Beard D Epos Group N
Full Access

Introduction. Malalignment of some designs of stem is associated with an increased risk of aseptic loosening and revision. We investigated whether the alignment of the cemented polished, double-taper design adversely affected outcome, in a multicentre prospective study. Methods. A multicentre prospective study of 1189 total hip replacements was undertaken to investigate whether there is an association between surgical outcome and femoral stem alignment. All patients underwent a primary THR with the Exeter femoral stem (Stryker Howmedica Osteonics, Mahwah, NJ) and a variety of acetabular components. The primary outcome measure was the Oxford hip score (OHS) and change in OHS at five years. Secondary outcomes included rate of dislocation and revision. Radiographic evaluation of the femoral component was also undertaken. The long axis of the Exeter femoral component and the long axis of the femoral canal were located, and the angle at the point of intersection measured. The cementing quality was determined as defined by Barrack et al. Radiolucent lines at the cement-stem and cement-bone interface in the five year radiographs were defined using the zones described by Gruen et al. Subsidence was measured as the vertical dimension of the radiolucency craniolateral to the shoulder of the stem in Gruen zone 1 as described by Fowler et al. Cement fractures were recorded. Results. The incidence of varus (>5 ° to the femoral axis), and valgus (>5 °) malignment were 3.7% and 0.8% respectively. Pre-operative demographics and OHS were similar in all groups (p > 0.4). There was no significant difference in OHS or change in OHS between neutral and malaligned groups at 5 years (neutral, mean=40.1, change=23.1; varus, mean=40.1, change=23.7; valgus, mean=42.0, change=26.6; p=0.46 and p=0.45 respectively). There was no significant difference in dislocation rate between the groups (p=0.66). There was also no significant difference in revision rate (p=0.34). There were no statistically significant differences in the incidence of femoral radiolucency, stem subsidence or cement fracture (p > 0.1). Conclusion. This study provides evidence that both varus and valgus implantation does not compromise the short to medium term clinical results of the cemented, polished, double-taper stems. Longer follow-up is required to establish the influence of stem alignment on the incidence of aseptic loosening and revision


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIII | Pages 14 - 14
1 Jul 2012
Bell S Young P Drury C Jones CB Blyth M MacLean A
Full Access

Total knee arthroplasty (TKA) is an established and successful operation. However patient satisfaction rates vary from 81 to 89% 1,2,3. Pain following TKA is a significant factor in patient dissatisfaction 1. Many causes for pain following total knee arthroplasty have been identified 4 but rates of unexplained pain vary from 4 to 13.1% 5,6. Recently computerised tomography (CT) has been used to assess the rotational profile of both the tibial and femoral components in painful TKA. We reviewed 57 patients with an unexplained painful following TKA and compared these to a matched control group of 60 patients with TKA. Datum gathered from case notes and radiographs using a prospective database to identify patients. The CT information recorded was limb alignment, tibial component rotation, and femoral component rotation and combined rotation. The two matched cohorts of patients had similar demographics. A significant difference in tibial, femoral and combined component rotation was identified between the groups. The following mean rotations were identified for the painful and control groups respectively. Tibial rotation was 3.46 degrees internal rotation (IR) compared to 2.50 degrees external rotation (ER)(p=0.001). Femoral rotation was 2.30 IR compared to 0.36 ER(p=0.02). Combined rotation was 7.08 IR compared to 2.85 ER(p=0.001). This is the largest study presently in the literature. We have identified significant internal rotation in a patient cohort with unexplained painful TKA when compared to a matched control group. Internal rotation of the tibial component, femoral component and combined rotation was identified as a factor in unexplained pain following TKA


Background:. Acute deformity correction with the help of osteotomies and stabilisation with intramedullary (IM) nail is a recognised technique. We present our case series of long bong deformity correction using an innovative technique that aids accurate correction after osteotomy and insertion of IM nail. Technique:. On preoperative measurements the distance of the joint surface from the point of intersection of the joint orientation angle with the convex cortex and also its distance from apex of deformity were noted. These distances were reproduced intraoperatively and guide pin was inserted towards premeasured point in the convex cortex. Osteotomy was performed and appropriate sized locked IM nail inserted with the help of temporary blocking screws, resulting in the correction of deformities. Method:. Retrospective review of case notes and radiographs was performed of five patients who underwent long bone deformity correction using this technique. Average age of patients was 15.2yrs. Underlying diagnosis were hypophosphataemic rickets, growth arrests and juvenile osteoporosis. Results:. Length of follow up was from 6 to 24 months. All osteotomies had healed at an average of 46 days. Of the eleven bone segments, nine had normal alignment (within 2.5° of normal or contralateral side). In the other two bone segments the alignment was between 2.5° and 5°. Blocking screws were not used in both these cases. Conclusions:. This is a simple technique of deformity correction. Keys to improve accuracy of correction are preoperative planning, intraoperative blocking screws and oblique osteotomies to accommodate translation


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 544 - 544
1 Sep 2012
Hoppe S Frauchiger L Mainzer J Ballmer P Hess R Zumstein M
Full Access

Background

Navigation in total knee replacement is controversially discussed in the literature. In our previous study, femoral component positioning was more accurate with computed navigation than with conventional implantation techniques, however tibial positioning showed similar results. Moreover there were no differences between image-free and image-based navigation techniques. To what extent more accurate femoral positioning has an impact on the clinical mid-term follow up is not known.

Methods

At a mean follow-up interval of 5.3 years, seventy-one patients (84.5%) returned for a review and were examined clinically and radiographically, with use of a methodology identical to that used preop and at 2 years, using the subjective value, the Knee Society Score (KSS), and a.p. and true lateral standard radiographs respectively. Complications, re-operations, persisting pain and resulting range of motion were registered.


Bone & Joint Open
Vol. 3, Issue 2 | Pages 165 - 172
21 Feb 2022
Kuwahara Y Takegami Y Tokutake K Yamada Y Komaki K Ichikawa T Imagama S

Aims. Postoperative malalignment of the femur is one of the main complications in distal femur fractures. Few papers have investigated the impact of intraoperative malalignment on postoperative function and bone healing outcomes. The aim of this study was to investigate how intraoperative fracture malalignment affects postoperative bone healing and functional outcomes. Methods. In total, 140 patients were retrospectively identified from data obtained from a database of hospitals participating in a trauma research group. We divided them into two groups according to coronal plane malalignment of more than 5°: 108 had satisfactory fracture alignment (< 5°, group S), and 32 had unsatisfactory alignment (> 5°, group U). Patient characteristics and injury-related factors were recorded. We compared the rates of nonunion, implant failure, and reoperation as healing outcomes and Knee Society Score (KSS) at three, six, and 12 months as functional outcomes. We also performed a sub-analysis to assess the effect of fracture malalignment by plates and nails on postoperative outcomes. Results. The rates of nonunion and reoperation in group U were worse than those in group S (25.0% vs 14.3%; 15.6% vs 5.6%), but the differences were not significant (p = 0.180 and p = 0.126, respectively). Mean KSS in group U at all follow-up periods was significantly worse that in group S (75.7 (SD 18.8) vs 86.0 (SD 8.7); p < 0.001; 78.9 (SD 17.2) vs 89.1 (SD 9.8); p < 0.001; 85.0 (SD 11.9) vs 91.1 (SD 7.2); p = 0.002, respectively). In the sub-analysis of plates, mean KSS was significantly worse in group U at three and six months. In the sub-analysis of nails, the rate of reoperation was significantly higher in group U (28.6% vs 5.8%; p = 0.025), and mean KSS at six and 12 months was significantly worse in Group U. Conclusion. To obtain good postoperative functional results, intraoperative alignment of the coronal plane should be accurately restored to less than 5°. Cite this article: Bone Jt Open 2022;3(2):165–172


The Bone & Joint Journal
Vol. 103-B, Issue 2 | Pages 294 - 298
1 Feb 2021
Hadeed MM Prakash H Yarboro SR Weiss DB

Aims. The aim of this study was to determine the immediate post-fixation stability of a distal tibial fracture fixed with an intramedullary nail using a biomechanical model. This was used as a surrogate for immediate weight-bearing postoperatively. The goal was to help inform postoperative protocols. Methods. A biomechanical model of distal metaphyseal tibial fractures was created using a fourth-generation composite bone model. Three fracture patterns were tested: spiral, oblique, and multifragmented. Each fracture extended to within 4 cm to 5 cm of the plafond. The models were nearly-anatomically reduced and stabilized with an intramedullary nail and three distal locking screws. Cyclic loading was performed to simulate normal gait. Loading was completed in compression at 3,000 N at 1 Hz for a total of 70,000 cycles. Displacement (shortening, coronal and sagittal angulation) was measured at regular intervals. Results. The spiral and oblique fracture patterns withstood simulated weight-bearing with minimal displacement. The multifragmented model had early implant failure with breaking of the distal locking screws. The spiral fracture model shortened by a mean of 0.3 mm (SD 0.2), and developed a mean coronal angulation of 2.0° (SD 1.9°) and a mean sagittal angulation of 1.2° (SD 1.1°). On average, 88% of the shortening, 74% of the change in coronal alignment, and 75% of the change in sagittal alignment occurred in the first 2,500 cycles. No late acceleration of displacement was noted. The oblique fracture model shortened by a mean of 0.2 mm (SD 0.1) and developed a mean coronal angulation of 2.4° (SD 1.6°) and a mean sagittal angulation of 2.6° (SD 1.4°). On average, 44% of the shortening, 39% of the change in coronal alignment, and 79% of the change in sagittal alignment occurred in the first 2,500 cycles. No late acceleration of displacement was noted. Conclusion. For spiral and oblique fracture patterns, simulated weight-bearing resulted in a clinically acceptable degree of displacement. Most displacement occurred early in the test period, and the rate of displacement decreased over time. Based on this model, we offer evidence that early weight-bearing appears safe for well reduced oblique and spiral fractures, but not in multifragmented patterns that have poor bone contact. Cite this article: Bone Joint J 2021;103-B(2):294–298


Aims. Our objective was to conduct a systematic review and meta-analysis, to establish whether differences arise in clinical outcomes between autologous and synthetic bone grafts in the operative management of tibial plateau fractures. Methods. A structured search of MEDLINE, EMBASE, the online archives of Bone & Joint Publishing, and CENTRAL databases from inception until 28 July 2021 was performed. Randomized, controlled, clinical trials that compared autologous and synthetic bone grafts in tibial plateau fractures were included. Preclinical studies, clinical studies in paediatric patients, pathological fractures, fracture nonunion, or chondral defects were excluded. Outcome data were assessed using the Risk of Bias 2 (ROB2) framework and synthesized in random-effect meta-analysis. The Preferred Reported Items for Systematic Review and Meta-Analyses guidance was followed throughout. Results. Six studies involving 353 fractures were identified from 3,078 records. Following ROB2 assessment, five studies (representing 338 fractures) were appropriate for meta-analysis. Primary outcomes showed non-significant reductions in articular depression at immediate postoperative (mean difference -0.45 mm, p = 0.25, 95%confidence interval (CI) -1.21 to 0.31, I. 2. = 0%) and long-term (> six months, standard mean difference -0.56, p = 0.09, 95% CI -1.20 to 0.08, I. 2. = 73%) follow-up in synthetic bone grafts. Secondary outcomes included mechanical alignment, limb functionality, and defect site pain at long-term follow-up, perioperative blood loss, duration of surgery, occurrence of surgical site infections, and secondary surgery. Mean blood loss was lower (90.08 ml, p < 0.001, 95% CI 41.49 to 138.67) and surgery was shorter (16.17 minutes, p = 0.04, 95% CI 0.39 to 31.94) in synthetic treatment groups. All other secondary measures were statistically comparable. Conclusion. All studies reported similar methodologies and patient populations; however, imprecision may have arisen through performance variation. These findings supersede previous literature and indicate that, despite perceived biological advantages, autologous bone grafting does not demonstrate superiority to synthetic grafts. When selecting a void filler, surgeons should consider patient comorbidity, environmental and societal factors in provision, and perioperative and postoperative care provision. Cite this article: Bone Jt Open 2022;3(3):218–228


Bone & Joint Open
Vol. 4, Issue 8 | Pages 602 - 611
21 Aug 2023
James HK Pattison GTR Griffin J Fisher JD Griffin DR

Aims

To evaluate if, for orthopaedic trainees, additional cadaveric simulation training or standard training alone yields superior radiological and clinical outcomes in patients undergoing dynamic hip screw (DHS) fixation or hemiarthroplasty for hip fracture.

Methods

This was a preliminary, pragmatic, multicentre, parallel group randomized controlled trial in nine secondary and tertiary NHS hospitals in England. Researchers were blinded to group allocation. Overall, 40 trainees in the West Midlands were eligible: 33 agreed to take part and were randomized, five withdrew after randomization, 13 were allocated cadaveric training, and 15 were allocated standard training. The intervention was an additional two-day cadaveric simulation course. The control group received standard on-the-job training. Primary outcome was implant position on the postoperative radiograph: tip-apex distance (mm) (DHS) and leg length discrepancy (mm) (hemiarthroplasty). Secondary clinical outcomes were procedure time, length of hospital stay, acute postoperative complication rate, and 12-month mortality. Procedure-specific secondary outcomes were intraoperative radiation dose (for DHS) and postoperative blood transfusion requirement (hemiarthroplasty).


Bone & Joint Open
Vol. 5, Issue 3 | Pages 236 - 242
22 Mar 2024
Guryel E McEwan J Qureshi AA Robertson A Ahluwalia R

Aims

Ankle fractures are common injuries and the third most common fragility fracture. In all, 40% of ankle fractures in the frail are open and represent a complex clinical scenario, with morbidity and mortality rates similar to hip fracture patients. They have a higher risk of complications, such as wound infections, malunion, hospital-acquired infections, pressure sores, veno-thromboembolic events, and significant sarcopaenia from prolonged bed rest.

Methods

A modified Delphi method was used and a group of experts with a vested interest in best practice were invited from the British Foot and Ankle Society (BOFAS), British Orthopaedic Association (BOA), Orthopaedic Trauma Society (OTS), British Association of Plastic & Reconstructive Surgeons (BAPRAS), British Geriatric Society (BGS), and the British Limb Reconstruction Society (BLRS).


The Bone & Joint Journal
Vol. 105-B, Issue 4 | Pages 449 - 454
15 Mar 2023
Zhang C Wang C Duan N Zhou D Ma T

Aims

The aim of this study was to assess the safety and clinical outcome of patients with a femoral shaft fracture and a previous complex post-traumatic femoral malunion who were treated with a clamshell osteotomy and fixation with an intramedullary nail (IMN).

Methods

The study involved a retrospective analysis of 23 patients. All had a previous, operatively managed, femoral shaft fracture with malunion due to hardware failure. They were treated with a clamshell osteotomy between May 2015 and March 2020. The mean age was 42.6 years (26 to 62) and 15 (65.2%) were male. The mean follow-up was 2.3 years (1 to 5). Details from their medical records were analyzed. Clinical outcomes were assessed using the quality of correction of the deformity, functional recovery, the healing time of the fracture, and complications.


Bone & Joint Open
Vol. 5, Issue 6 | Pages 457 - 463
2 Jun 2024
Coviello M Abate A Maccagnano G Ippolito F Nappi V Abbaticchio AM Caiaffa E Caiaffa V

Aims

Proximal femur fractures treatment can involve anterograde nailing with a single or double cephalic screw. An undesirable failure for this fixation is screw cut-out. In a single-screw nail, a tip-apex distance (TAD) greater than 25 mm has been associated with an increased risk of cut-out. The aim of the study was to examine the role of TAD as a risk factor in a cephalic double-screw nail.

Methods

A retrospective study was conducted on 112 patients treated for intertrochanteric femur fracture with a double proximal screw nail (Endovis BA2; EBA2) from January to September 2021. The analyzed variables were age, sex, BMI, comorbidities, fracture type, side, time of surgery, quality of reduction, pre-existing therapy with bisphosphonate for osteoporosis, screw placement in two different views, and TAD. The last follow-up was at 12 months. Logistic regression was used to study the potential factors of screw cut-out, and receiver operating characteristic curve to identify the threshold value.


Bone & Joint Open
Vol. 5, Issue 1 | Pages 37 - 45
19 Jan 2024
Alm CE Karlsten A Madsen JE Nordsletten L Brattgjerd JE Pripp AH Frihagen F Röhrl SM

Aims

Despite limited clinical scientific backing, an additional trochanteric stabilizing plate (TSP) has been advocated when treating unstable trochanteric fractures with a sliding hip screw (SHS). We aimed to explore whether the TSP would result in less post operative fracture motion, compared to SHS alone.

Methods

Overall, 31 patients with AO/OTA 31-A2 trochanteric fractures were randomized to either a SHS alone or a SHS with an additional TSP. To compare postoperative fracture motion, radiostereometric analysis (RSA) was performed before and after weightbearing, and then at four, eight, 12, 26, and 52 weeks. With the “after weightbearing” images as baseline, we calculated translations and rotations, including shortening and medialization of the femoral shaft.


The Bone & Joint Journal
Vol. 104-B, Issue 8 | Pages 963 - 971
1 Aug 2022
Sun Z Liu W Liu H Li J Hu Y Tu B Wang W Fan C

Aims

Heterotopic ossification (HO) is a common complication after elbow trauma and can cause severe upper limb disability. Although multiple prognostic factors have been reported to be associated with the development of post-traumatic HO, no model has yet been able to combine these predictors more succinctly to convey prognostic information and medical measures to patients. Therefore, this study aimed to identify prognostic factors leading to the formation of HO after surgery for elbow trauma, and to establish and validate a nomogram to predict the probability of HO formation in such particular injuries.

Methods

This multicentre case-control study comprised 200 patients with post-traumatic elbow HO and 229 patients who had elbow trauma but without HO formation between July 2019 and December 2020. Features possibly associated with HO formation were obtained. The least absolute shrinkage and selection operator regression model was used to optimize feature selection. Multivariable logistic regression analysis was applied to build the new nomogram: the Shanghai post-Traumatic Elbow Heterotopic Ossification Prediction model (STEHOP). STEHOP was validated by concordance index (C-index) and calibration plot. Internal validation was conducted using bootstrapping validation.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_8 | Pages 36 - 36
1 May 2018
Fawdington R Beaven A Fenton P Lofti N
Full Access

Background. In a systematic review of 1125 distal tibia fractures treated with an intramedullary nail, the reported incidence of malalignment was 14%. The purpose of our study is to assess whether the addition of blocking screws during intramedullary nailing of a distal tibia fracture improved radiological outcomes. As a secondary outcome, the time to radiographic union was compared to see if a more rigid bone-implant construct had an effect on healing. Methods. We searched computerised records at a UK level 1 major trauma centre. The joint alignment was measured on the immediate post-operative radiograph and compared to the most recent radiograph. We used a difference of 2 degrees to indicate a progressive deformity and a RUST score greater or equal to 10, to indicate radiographic fracture union. Results. Twenty-seven patients were included. Nineteen patients had no blocking screw and 8 patients had a blocking screw. Five patients had a difference in their coronal plane alignment of 2 degrees or more (3/5 had no blocking screw). The results were analysed and found to be not statistically significant (p=0.88). The addition of a blocking screw has also been shown not to have an effect on the time to union. Conclusion. We have changed our surgical practice. We use a 2.5mm blocking wire to aid in fracture reduction prior to reaming / nail insertion and then remove the wire when the nail has been adequately locked. Implications. This could save surgical procedure time, radiation exposure for the patient, implant costs and potential complications


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_3 | Pages 11 - 11
1 Feb 2020
Johnston WD Razii N Banger MS Rowe PJ Jones BG MacLean AD Blyth MJG
Full Access

The objective of this study was to compare differences in alignment following robotic arm-assisted bi-unicompartmental knee arthroplasty (Bi-UKA) and conventional total knee arthroplasty (TKA). This was a prospective, randomised controlled trial of 70 patients. 39 TKAs were implanted manually, as per standard protocol at our institution, and 31 Bi-UKA patients simultaneously received fixed-bearing medial and lateral UKAs, implanted using robotic arm-assistance. Preoperative and 3-month postoperative CT scans were analysed to determine hip knee ankle angle (HKAA), medial distal femoral angle (MDFA), and medial proximal tibial angle (MPTA). Analysis was repeated for 10 patients by a second rater to validate measurement reliability by calculating the intra-class correlation coefficient (ICC). Mean change in HKAA towards neutral was 2.7° in TKA patients and 2.3° in Bi-UKA patients (P=0.6). Mean change in MDFA was 2.5° for TKA and 1.0° for Bi-UKA (P<0.01). Mean change in MPTA was 3.7° for TKA and 0.8° for Bi-UKA (P<0.01). Mean postoperative MDFA and MPTA for TKAs were 89.8° and 89.6° respectively, indicating orientation of femoral and tibial components perpendicular to the mechanical axis. Mean postoperative MDFA and MPTA for Bi-UKAs were 91.0° and 86.9° respectively, indicating a more oblique joint line orientation. Inter-rater agreement was excellent (ICC>0.99). Early functional activities, according to the new Knee Society Scoring System, favoured Bi-UKAs (P<0.05). Robotic arm-assisted, cruciate-sparing Bi-UKA better maintains the natural anatomy of the knee in the coronal plane and may therefore preserve normal joint kinematics, compared to a mechanically aligned TKA. This has been achieved without significantly altering overall HKAA


The Bone & Joint Journal
Vol. 102-B, Issue 4 | Pages 530 - 538
1 Apr 2020
Rollick NC Gadinsky NE Klinger CE Kubik JF Dyke JP Helfet DL Wellman DS

Aims. Dual plating of distal femoral fractures with medial and lateral implants has been performed to improve construct mechanics and alignment, in cases where isolated lateral plating would be insufficient. This may potentially compromise vascularity, paradoxically impairing healing. This study investigates effects of single versus dual plating on distal femoral vascularity. Methods. A total of eight cadaveric lower limb pairs were arbitrarily assigned to either 1) isolated lateral plating, or 2) lateral and medial plating of the distal femur, with four specimens per group. Contralateral limbs served as matched controls. Pre- and post-contrast MRI was performed to quantify signal intensity enhancement in the distal femur. Further evaluation of intraosseous vascularity was done with barium sulphate infusion with CT scan imaging. Specimens were then injected with latex medium and dissection was completed to assess extraosseous vasculature. Results. Quantitative MRI revealed a mean reduction of 21.2% (SD 1.3%) of arterial contribution in the lateral plating group and 25.4% (SD 3.2%) in the dual plating group (p = 0.051); representing a mean decrease in arterial contribution of 4.2%. The only significant difference found between both experimental groups was regionally, at the lateral aspect of the distal femur with a mean drop in arterial contribution in the lateral plating group of 18.9% (SD 2.6%) versus 24.0% (SD 3.2%) in the dual plating group (p = 0.048), representing a mean decrease in arterial contribution of 5.1%. Gross dissection revealed complete destruction of periosteal vessels underneath either medial or lateral plates in both groups. The network of genicular branches contributing to the posterior and distal femoral condyles was preserved in all specimens. A medial vascular pedicle was found dividing from the superficial femoral artery at a mean 12.7 cm (SD 1.7) proximal to the medial epicondyle and was undisrupted in the dual plating group. Conclusion. Lateral locking-plate application resulted in mean 21.2% reduction in distal femur vascularity. Addition of medial plates did not further markedly decrease vascularity. As such, the majority of the vascular insult occurred with lateral plating alone. Supplemental medially based fixation did not lead to marked devascularization of the distal femur, and should therefore be considered in the setting of comminution and poor bone stock in distal femoral fractures. Further clinical research is required to confirm the results of this study. Cite this article: Bone Joint J 2020;102-B(4):530–538