Advertisement for orthosearch.org.uk
Results 1 - 20 of 272
Results per page:
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 38 - 38
2 May 2024
Buadooh KJ Holmes B Ng A
Full Access

The Revision Hip Complexity Classification (RHCC) was developed by modified Delphi system in 2022 to provide a comprehensive, reproducible framework for the multidisciplinary discussion of complex revision hip surgery. The aim of this study was to assess the validity, intra-relater and inter-relater reliability of the RHCC. Radiographs and clinical vignettes of 20 consecutive patients who had undergone revision of Total Hip Arthroplasty (THA) at our unit during the previous 12-month period were provided to observers. Five observers, comprising 3 revision hip consultants, 1 hip fellow and 1 ST3-8 registrar were familiarised with the RHCC. Each revision THA case was classified on two separate occasions by each observer, with a mean time between assessments of 42.6 days (24–57). Inter-observer reliability was assessed using the Fleiss™ Kappa statistic and percentage agreement. Intra-observer reliability was assessed using the Cohen Kappa statistic. Validity was assessed using percentage agreement and Cohen Kappa comparing observers to the RHCC web-based application result. All observers were blinded to patient notes, operation notes and post-operative radiographs throughout the process. Inter-observer reliability showed fair agreement in both rounds 1 and 2 of the survey (0.296 and 0.353 respectively), with a percentage agreement of 69% and 75%. Inter-observer reliability was highest in H3-type revisions with kappa values of 0.577 and 0.441. Mean intra-observer reliability showed moderate agreement with a kappa value of 0.446 (0.369 to 0.773). Validity percentage agreement was 44% and 39% respectively, with mean kappa values of 0.125 and 0.046 representing only slight agreement. This study demonstrates that classification using the RHCC without utilisation of the web-based application is unsatisfactory, showing low validity and reliability. Reliability was higher for more complex H3-type cases. The use of the RHCC web app is recommended to ensure the accurate and reliable classification of revision THA cases


The Bone & Joint Journal
Vol. 103-B, Issue 8 | Pages 1339 - 1344
1 Aug 2021
Jain S Mohrir G Townsend O Lamb JN Palan J Aderinto J Pandit H

Aims. This aim of this study was to assess the reliability and validity of the Unified Classification System (UCS) for postoperative periprosthetic femoral fractures (PFFs) around cemented polished taper-slip (PTS) stems. Methods. Radiographs of 71 patients with a PFF admitted consecutively at two centres between 25 February 2012 and 19 May 2020 were collated by an independent investigator. Six observers (three hip consultants and three trainees) were familiarized with the UCS. Each PFF was classified on two separate occasions, with a mean time between assessments of 22.7 days (16 to 29). Interobserver reliability for more than two observers was assessed using percentage agreement and Fleiss’ kappa statistic. Intraobserver reliability between two observers was calculated with Cohen kappa statistic. Validity was tested on surgically managed UCS type B PFFs where stem stability was documented in operation notes (n = 50). Validity was assessed using percentage agreement and Cohen kappa statistic between radiological assessment and intraoperative findings. Kappa statistics were interpreted using Landis and Koch criteria. All six observers were blinded to operation notes and postoperative radiographs. Results. Interobserver reliability percentage agreement was 58.5% and the overall kappa value was 0.442 (moderate agreement). Lowest kappa values were seen for type B fractures (0.095 to 0.360). The mean intraobserver reliability kappa value was 0.672 (0.447 to 0.867), indicating substantial agreement. Validity percentage agreement was 65.7% and the mean kappa value was 0.300 (0.160 to 0.4400) indicating only fair agreement. Conclusion. This study demonstrates that the UCS is unsatisfactory for the classification of PFFs around PTS stems, and that it has considerably lower reliability and validity than previously described for other stem types. Radiological PTS stem loosening in the presence of PFF is poorly defined and formal intraoperative testing of stem stability is recommended. Cite this article: Bone Joint J 2021;103-B(8):1339–1344


The Bone & Joint Journal
Vol. 106-B, Issue 9 | Pages 898 - 906
1 Sep 2024
Kayani B Wazir MUK Mancino F Plastow R Haddad FS

Aims. The primary objective of this study was to develop a validated classification system for assessing iatrogenic bone trauma and soft-tissue injury during total hip arthroplasty (THA). The secondary objective was to compare macroscopic bone trauma and soft-tissues injury in conventional THA (CO THA) versus robotic arm-assisted THA (RO THA) using this classification system. Methods. This study included 30 CO THAs versus 30 RO THAs performed by a single surgeon. Intraoperative photographs of the osseous acetabulum and periacetabular soft-tissues were obtained prior to implantation of the acetabular component, which were used to develop the proposed classification system. Interobserver and intraobserver variabilities of the proposed classification system were assessed. Results. The BOne trauma and Soft-Tissue Injury classification system in total Hip arthroplasty (BOSTI Hip) grades osseous acetabular trauma and periarticular muscle damage during THA. The classification system has an interclass correlation coefficient of 0.90 (95% CI 0.86 to 0.93) for interobserver agreement and 0.89 (95% CI 0.84 to 0.93) for intraobserver agreement. RO THA was associated with improved BOSTI Hip scores (p = 0.002) and more pristine osseous surfaces in the anterior superior (p = 0.001) and posterior superior (p < 0.001) acetabular quadrants compared with CO THA. There were no differences between the groups in relation to injury to the gluteus medius (p = 0.084), obturator internus (p = 0.241), piriformis (p = 0.081), superior gamellus (p = 0.116), inferior gamellus (p = 0.132), quadratus femoris (p = 0.208), and vastus lateralis (p = 0.135), but overall combined muscle injury was reduced in RO THA compared with CO THA (p = 0.023). Discussion. The proposed BOSTI Hip classification provides a reproducible grading system for stratifying iatrogenic bone trauma and soft-tissue injury during THA. RO THA was associated with improved BOSTI Hip scores, more pristine osseous acetabular surfaces, and reduced combined periarticular muscle injury compared with CO THA. Further research is required to understand if these intraoperative findings translate to differences in clinical outcomes between the treatment groups. Cite this article: Bone Joint J 2024;106-B(9):898–906


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 82 - 82
19 Aug 2024
Courington R Ferreira R Shaath MK Green C Langford J Haidukewych G
Full Access

When treating periprosthetic femur fractures (PPFFs) around total hip arthroplasty (THA)], determining implant fixation status preoperatively is important, since this guides treatment regarding ORIF versus revision. The purpose of this study was to determine the accuracy of preoperative implant fixation status determination utilizing plain films and CT scans. Twenty-four patients who underwent surgery for Vancouver B type PPFF were included in the study. Two joint surgeons and two traumatologists reviewed plain films alone and made a judgment on fixation status. They then reviewed CT scans and fixation status was reassessed. Concordance and discordance were recorded. Interobserver reliability was assessed using Kendall's W and intraobserver reliability was assessed using Cohen's Kappa. Ultimately, the “correct” response was determined by intraoperative findings, as we routinely test the component intraoperatively. Fifteen implants were found to be well-fixed (63%) and 9 were loose. Plain radiographs alone predicted correct fixation status in 53% of cases. When adding the CT data, the correct prediction only improved to 55%. Interestingly, concordance between plain radiographs and CT was noted in 82%. In concordant cases, the fixation status was found to be correct in 55% of cases. Of the 18% of cases with discordance, plain films were correct in 43% of cases, and the CT was correct in 57%. Interobserver reliability demonstrated poor agreement on plain films and moderate agreement on CT. Intraobserver reliability demonstrated moderate agreement on both plain films and CT. The ability to determine fixation status for proximal PPFFs around uncemented femoral components remains challenging. The addition of routine CT scanning did not significantly improve accuracy. We recommend careful intraoperative testing of femoral component fixation with surgical dislocation if necessary, and the surgeon should be prepared to revise or fix the fracture based on those findings


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_11 | Pages 35 - 35
7 Jun 2023
Warder H Sanders T Wright N Hall-Thompson B Alford S Johnson D
Full Access

Climbers and mountaineers will present to arthroplasty surgeons in need of hip replacement surgeries. There is a lack of guidance for both parties with a paucity in the literature. Climbing is often considered a high-risk activity to perform with a total hip replacement, due to the positions the hip is weighted in, and the potential austere environment in which an injury may occur. The aim was to assess levels of climbing and mountaineering possible following hip arthroplasty, and any factors affecting these levels. Ethical approval was obtained from the University of Central Lancashire. An anonymous online questionnaire was disseminated via email, social media and word-of-mouth to include all climbers, hill-walkers or mountaineers across the UK. This was used to collect climbing and mountaineering ability at various timepoints, along with scores such as the Oxford Hip Score and UCLA Score. The Kappa statistic was used to assess for correlations. Of the responders, 28 had undergone right hip arthroplasty surgery, with 11 having left hips and 22 receiving bilateral hips. A total of 67 of the replaced hips were total hip replacements, with 16 having undergone hip resurfacing. There is a fair agreement in level of climbing ability 3 months pre- and 3 months post-operatively (kappa=0.287, p<0.001), and a substantial agreement between 1 year post-operatively and currently for both climbing (kappa=0.730, p<0.001) and mountaineering (kappa=0.684, p<0.001). Impressively, 17 participants are climbing at more than E1 trad or 6c sport at one or more time points post operatively, which is regarded as an advanced level within the climbing community. Out of those 17 participants, 8 were climbing at this level within 3 months post-operatively. The level of climbing possible following hip arthroplasty surgery is above what is expected and perhaps desired by the operating surgeon. It is essential to take the individual patient into account when planning an operative intervention such as arthroplasty. The one year post-operative time point is highly predictive of longer term outcomes for both climbing and mountaineering


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 27 - 27
23 Jun 2023
Chen K Wu J Xu L Han X Chen X
Full Access

To propose a modified approach to measuring femoro-epiphyseal acetabular roof (FEAR) index while still abiding by its definition and biomechanical basis, and to compare the reliabilities of the two methods. To propose a classification for medial sourcil edges. We retrospectively reviewed a consecutive series of patients treated with periacetabular osteotomy and/or hip arthroscopy. A modified FEAR index was defined. Lateral center-edge angle, Sharp's angle, Tonnis angle on all hips, as well as FEAR index with original and modified approaches were measured. Intra- and inter-observer reliability were calculated as intraclass correlation coefficients (ICC) for FEAR index with both approaches and other alignments. A classification was proposed to categorize medial sourcil edges. ICC for the two approaches across different sourcil groups were also calculated. After reviewing 411 patients, 49 were finally included. Thirty-two patients (40 hips) were identified as having borderline dysplasia defined by an LCEA of 18 to 25 degrees. Intra-observer ICC for the modified method were good to excellent for borderline hips; poor to excellent for DDH; moderate to excellent for normal hips. As for inter-observer reliability, modified approach outperformed original approach with moderate to good inter-observer reliability (DDH group, ICC=0.636; borderline dysplasia group, ICC=0.813; normal hip group, ICC=0.704). The medial sourcils were classified to 3 groups upon its morphology. Type II(39.0%) and III(43.9%) sourcils were the dominant patterns. The sourcil classification had substantial intra-observer agreement (observer 4, kappa=0.68; observer 1, kappa=0.799) and moderate inter-observer agreement (kappa=0.465). Modified approach to FEAR index possessed greater inter-observer reliability in all medial sourcil patterns. The modified FEAR index has better intra- and inter-observer reliability compared with the original approach. Type II and III sourcils accounts for the majority to which only the modified approach is applicable


The Bone & Joint Journal
Vol. 103-B, Issue 8 | Pages 1345 - 1350
1 Aug 2021
Czubak-Wrzosek M Nitek Z Sztwiertnia P Czubak J Grzelecki D Kowalczewski J Tyrakowski M

Aims. The aim of the study was to compare two methods of calculating pelvic incidence (PI) and pelvic tilt (PT), either by using the femoral heads or acetabular domes to determine the bicoxofemoral axis, in patients with unilateral or bilateral primary hip osteoarthritis (OA). Methods. PI and PT were measured on standing lateral radiographs of the spine in two groups: 50 patients with unilateral (Group I) and 50 patients with bilateral hip OA (Group II), using the femoral heads or acetabular domes to define the bicoxofemoral axis. Agreement between the methods was determined by intraclass correlation coefficient (ICC) and the standard error of measurement (SEm). The intraobserver reproducibility and interobserver reliability of the two methods were analyzed on 31 radiographs in both groups to calculate ICC and SEm. Results. In both groups, excellent agreement between the two methods was obtained, with ICC of 0.99 and SEm 0.3° for Group I, and ICC 0.99 and SEm 0.4° for Group II. The intraobserver reproducibility was excellent for both methods in both groups, with an ICC of at least 0.97 and SEm not exceeding 0.8°. The study also revealed excellent interobserver reliability for both methods in both groups, with ICC 0.99 and SEm 0.5° or less. Conclusion. Either the femoral heads or acetabular domes can be used to define the bicoxofemoral axis on the lateral standing radiographs of the spine for measuring PI and PT in patients with idiopathic unilateral or bilateral hip OA. Cite this article: Bone Joint J 2021;103-B(8):1345–1350


Bone & Joint Open
Vol. 2, Issue 10 | Pages 858 - 864
18 Oct 2021
Guntin J Plummer D Della Valle C DeBenedetti A Nam D

Aims. Prior studies have identified that malseating of a modular dual mobility liner can occur, with previous reported incidences between 5.8% and 16.4%. The aim of this study was to determine the incidence of malseating in dual mobility implants at our institution, assess for risk factors for liner malseating, and investigate whether liner malseating has any impact on clinical outcomes after surgery. Methods. We retrospectively reviewed the radiographs of 239 primary and revision total hip arthroplasties with a modular dual mobility liner. Two independent reviewers assessed radiographs for each patient twice for evidence of malseating, with a third observer acting as a tiebreaker. Univariate analysis was conducted to determine risk factors for malseating with Youden’s index used to identify cut-off points. Cohen’s kappa test was used to measure interobserver and intraobserver reliability. Results. In all, 12 liners (5.0%), including eight Stryker (6.8%) and four Zimmer Biomet (3.3%), had radiological evidence of malseating. Interobserver reliability was found to be 0.453 (95% confidence interval (CI) 0.26 to 0.64), suggesting weak inter-rater agreement, with strong agreement being greater than 0.8. We found component size of 50 mm or less to be associated with liner malseating on univariate analysis (p = 0.031). Patients with malseated liners appeared to have no associated clinical consequences, and none required revision surgery at a mean of 14 months (1.4 to 99.2) postoperatively. Conclusion. The incidence of liner malseating was 5.0%, which is similar to other reports. Component size of 50 mm or smaller was identified as a risk factor for malseating. Surgeons should be aware that malseating can occur and implant design changes or changes in instrumentation should be considered to lower the risk of malseating. Although further follow-up is needed, it remains to be seen if malseating is associated with any clinical consequences. Cite this article: Bone Jt Open 2021;2(10):858–864


Bone & Joint Open
Vol. 3, Issue 11 | Pages 877 - 884
14 Nov 2022
Archer H Reine S Alshaikhsalama A Wells J Kohli A Vazquez L Hummer A DiFranco MD Ljuhar R Xi Y Chhabra A

Aims. Hip dysplasia (HD) leads to premature osteoarthritis. Timely detection and correction of HD has been shown to improve pain, functional status, and hip longevity. Several time-consuming radiological measurements are currently used to confirm HD. An artificial intelligence (AI) software named HIPPO automatically locates anatomical landmarks on anteroposterior pelvis radiographs and performs the needed measurements. The primary aim of this study was to assess the reliability of this tool as compared to multi-reader evaluation in clinically proven cases of adult HD. The secondary aims were to assess the time savings achieved and evaluate inter-reader assessment. Methods. A consecutive preoperative sample of 130 HD patients (256 hips) was used. This cohort included 82.3% females (n = 107) and 17.7% males (n = 23) with median patient age of 28.6 years (interquartile range (IQR) 22.5 to 37.2). Three trained readers’ measurements were compared to AI outputs of lateral centre-edge angle (LCEA), caput-collum-diaphyseal (CCD) angle, pelvic obliquity, Tönnis angle, Sharp’s angle, and femoral head coverage. Intraclass correlation coefficients (ICC) and Bland-Altman analyses were obtained. Results. Among 256 hips with AI outputs, all six hip AI measurements were successfully obtained. The AI-reader correlations were generally good (ICC 0.60 to 0.74) to excellent (ICC > 0.75). There was lower agreement for CCD angle measurement. Most widely used measurements for HD diagnosis (LCEA and Tönnis angle) demonstrated good to excellent inter-method reliability (ICC 0.71 to 0.86 and 0.82 to 0.90, respectively). The median reading time for the three readers and AI was 212 (IQR 197 to 230), 131 (IQR 126 to 147), 734 (IQR 690 to 786), and 41 (IQR 38 to 44) seconds, respectively. Conclusion. This study showed that AI-based software demonstrated reliable radiological assessment of patients with HD with significant interpretation-related time savings. Cite this article: Bone Jt Open 2022;3(11):877–884


Bone & Joint Research
Vol. 9, Issue 5 | Pages 242 - 249
1 May 2020
Bali K Smit K Ibrahim M Poitras S Wilkin G Galmiche R Belzile E Beaulé PE

Aims. The aim of the current study was to assess the reliability of the Ottawa classification for symptomatic acetabular dysplasia. Methods. In all, 134 consecutive hips that underwent periacetabular osteotomy were categorized using a validated software (Hip2Norm) into four categories of normal, lateral/global, anterior, or posterior. A total of 74 cases were selected for reliability analysis, and these included 44 dysplastic and 30 normal hips. A group of six blinded fellowship-trained raters, provided with the classification system, looked at these radiographs at two separate timepoints to classify the hips using standard radiological measurements. Thereafter, a consensus meeting was held where a modified flow diagram was devised, before a third reading by four raters using a separate set of 74 radiographs took place. Results. Intrarater results per surgeon between Time 1 and Time 2 showed substantial to almost perfect agreement among the raters (κappa = 0.416 to 0.873). With respect to inter-rater reliability, at Time 1 and Time 2 there was substantial agreement overall between all surgeons (Time 1 κappa = 0.619; Time 2 κappa = 0.623). Posterior and anterior rating categories had moderate and fair agreement at Time 1 (posterior κappa = 0.557; anterior κappa = 0.438) and Time 2 (posterior κappa = 0.506; anterior κappa = 0.250), respectively. At Time 3, overall reliability (κappa = 0.687) and posterior and anterior reliability (posterior κappa = 0.579; anterior κappa = 0.521) improved from Time 1 and Time 2. Conclusion. The Ottawa classification system provides a reliable way to identify three categories of acetabular dysplasia that are well-aligned with surgical management. The term ‘borderline dysplasia’ should no longer be used. Cite this article: Bone Joint Res. 2020;9(5):242–249


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 81 - 81
19 Aug 2024
Angelomenos V Shareghi B Itayem R Mohaddes M
Full Access

Early micromotion of hip implants measured with radiostereometric analysis (RSA) is a predictor for late aseptic loosening. Computed Tomography Radiostereometric Analysis (CT-RSA) can be used to determine implant micro-movements using low-dose CT scans. CT-RSA enables a non-invasive measurement of implants. We evaluated the precision of CT-RSA in measuring early stem migration. Standard marker-based RSA was used as reference. We hypothesised that CT-RSA can be used as an alternative to RSA in assessing implant micromotions. We included 31 patients undergoing Total Hip Arthroplasty (THA). Distal femoral stem migration at 1 year was measured with both RSA and CT-RSA. Comparison of the two methods was performed with paired-analysis and Bland-Altman plots. Furthermore, the inter- and intraobserver reliability of the CT-RSA method was evaluated. No statistical difference was found between RSA and CTMA measurements. The Bland-Altman plots showed good agreement between marker-based RSA and CT-RSA. The intra- and interobserver reliability of the CT-RSA method was found to be excellent (≥0.992). CT-RSA is comparable to marker-based RSA in measuring distal femoral stem migration. CTMA can be used as an alternative method to detect early implant migration


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 27 - 27
2 May 2024
Board T Nunley R Mont MA
Full Access

The purpose of this modified Delphi study was to obtain consensus on wound closure (including best practices for each tissue layer of closure) and dressing management in total hip arthroplasty (THA), using an evidence-based approach. The Delphi panel included 20 orthopedic surgeons from Europe and North America. Eighteen statements were identified (14 specific to THA and 4 relating to both THA and total knee arthroplasty) using a targeted literature review. Consensus was developed on the statements with up to three rounds of anonymous voting per topic. Panelists ranked their agreement with each statement on a five-point Likert scale. An a priori threshold of 75% was required for consensus. In Round 1, 15 of 18 statements achieved consensus via a structured electronic questionnaire. In Round 2, the 3 statements that did not achieve consensus were revised during a virtual face to face meeting. An additional 2 statements were edited for clarity. In Round 3, the 5 revised statements achieved consensus via a structured electronic questionnaire. Wound closure related interventions that were recommended for use in THA included: 1) barbed sutures over non-barbed sutures (shorter closing times and overall cost savings); 2) subcuticular sutures over skin staples (lower risk of infections and higher patient preference); 3) mesh-adhesives over silver-impregnated dressings (lower rate of wound complications); 4) negative pressure wound therapy over other dressings (lower wound complications and reoperations and fewer dressing changes); 5) triclosan coated sutures (lower risk of surgical site infection). Using a modified Delphi approach, a panel of 20 orthopedic surgeons achieved consensus on 18 statements pertaining to multi-layer wound closure and dressing management in THA. This study forms the basis for identifying critical evidence gaps within wound management to help reduce variability in outcomes during THA


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_11 | Pages 18 - 18
7 Jun 2023
Schapira B Spanoudakis E Jaiswal P Patel A
Full Access

Surgical trainees are finding it increasingly more challenging to meet operative requirements and coupled with the effects of COVID-19, we face a future of insufficiently trained surgeons. As a result, virtual reality (VR) simulator training has become more prevalent and whilst more readily accepted in certain arthroscopic fields, its use in hip arthroscopy (HA) remains novel. This project aimed to validate VR high-fidelity HA simulation and assess its functional use in arthroscopic training. Seventy-two participants were recruited to perform two basic arthroscopic tasks on a VR HA simulator, testing hip anatomy, scope manipulation and triangulation skills. They were stratified into novice (39) and experienced (33) groups based on previous arthroscopy experience. Metric parameters recorded from the simulator were used to assess construct validity. Face validity was evaluated using a Likert-style questionnaire. All recordings were reviewed by 2 HA experts for blinded ASSET score assessment. Experienced participants were significantly faster in completing both tasks compared with novice participants (p<0.001). Experienced participants damaged the acetabular and femoral cartilage significantly less than novice participants (p=0.011) and were found to have significantly reduced path length of both camera and instrument across both tasks (p=0.001, p=0.007), demonstrating significantly greater movement economy. Total ASSET scores were significantly greater in experienced participants compared to novice participants (p=0.041) with excellent correlation between task time, cartilage damage, camera and instrument path length and corresponding ASSET score constituents. 62.5% of experienced participants reported a high degree of realism in all facets of external, technical and haptic experience with 94.4% advising further practice would improve their arthroscopic skills. There was a relative improvement of 43% in skill amongst all participants between task 1 and 2 (p<0.001). This is the largest study to date validating the use of simulation in HA training. These results confirm significant construct and face validity, excellent agreement between objective measures and ASSET scores, significant improvement in skill with continued use and recommend VR simulation to be a valuable asset in HA training for all grades


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_4 | Pages 38 - 38
1 Apr 2022
Plastow R Kayani B Paton B Moriarty P Wilson M Court N Giakoumis M Read P Kerkhoffs G Moore J Murphy S Pollock N Stirling B Tulloch L Van Dyk N Wood D Haddad FS
Full Access

The 2020 London International Hamstring Consensus meeting was convened to improve our understanding and treatment of hamstring injuries. The multidisciplinary consensus panel included 14 International specialists on the management of hamstring injuries. The Delphi consensus process consisted of two rounds of surveys which were completed by 19 surgeons from a total of 106 participants. Consensus on individual statements was regarded as over 70% agreement between panel members. The consensus group agreed that the indications for operative intervention included the following: gapping at the zone of injury (86.9%); high functional demands of the patient (86.7%); symptomatic displaced bony avulsions (74.7%); and proximal free tendon injuries with functional compromise refractory to non-operative treatment (71.4%). Panel members agreed that surgical intervention had the capacity to restore anatomy and function, while reducing the risk of injury recurrence (86.7%). The consensus group did not support the use of corticosteroids or endoscopic surgery without further evidence. These guidelines will help to further standardise the treatment of hamstring injuries and facilitate decision-making in the surgical treatment of these injuries


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_12 | Pages 43 - 43
1 Oct 2019
Zochowski K Cheung J Argentieri EC Lin BQ Kaushik SS Burge AJ Koff MF Potter HG
Full Access

Introduction. MAVRIC-SL (MVSL), a multi-spectral magnetic resonance imaging (MRI) sequence [1] used for visualization of tissues near hip arthroplasty, can be accelerated by a short calibration scan [2], permitting an isotropic acquisition in a clinically feasible scan time. Decreasing the repetition time (TR) can further reduce scan time. This study evaluated the feasibility of acquiring isotropic MAVRIC-SL images (MVISO) and reduced TR isotropic MAVRIC-SL images (TRMVISO) of hip arthroplasties to elucidate the added clinical benefit of such acquisitions. Methods. Following IRB approval, MVSL, MVISO and TRMVISO images were acquired for 93 hip arthroplasties (84 subjects). Images were reviewed by 2 radiologists to evaluate clinical and image quality features. Comparison of features between scanning sequences was assessed by mixed-effects ordinal logistic regression and odds ratios (OR). Inter/intra-rater agreement was determined using Gwet's agreement coefficient (AC). Results. A calibration scan permitted acquisition of isotropic image sets in under 8 minutes. MVISO and TRMVISO had decreased blurring and improved visualization of the synovium and periprosthetic bone as compared to MVSL (p<0.001, Fig. 1). MVISO and TRMVISO improved image quality features over MVSL, OR range: 1 to 968. MVISO acquisitions also had better image quality, visualization of synovium and bone, lesion conspicuity, and decreased blurring than TRMVISO (p<0.032). Substantial to perfect (0.61 ≥ AC ≥ 1.0) agreement was found for 86% of factors evaluated by the 2 readers. Conclusions. The isotropic acquisitions displayed clinically relevant features better than MVSL, with notable improvement of blurring and overall image quality. The TRMVISO altered the image contrast and contributed to poorer visualization of synovial reactions as compared to MVISO. The study demonstrated that isotropic MAVRIC scans are clinically feasible, and that MVISO scans added clinical value through improved visualization by reducing blurring. For any tables or figures, please contact the authors directly


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_12 | Pages 48 - 48
1 Oct 2019
Anderson L Erickson J Peters CL
Full Access

Introduction. Radiographic assessment of acetabular fragment positioning during periacetabular osteotomy (PAO) is of paramount importance. Plain radiographic examination is time and resource intensive. Fluoroscopic based assessment is increasingly utilized but can introduce distortion. Our purpose was to determine the correlation of intraoperative fluoroscopy-based measurements with a fluoroscopic tool that corrects for distortion with postoperative plain-film measurements. Methods. We performed a prospective validation study on 32 PAO's (28 patients) performed by a single academic surgeon. Preoperative standing radiographs, intraoperative fluoroscopic images, and postoperative standing radiographs were evaluated with lateral center edge angle (LCEA), acetabular index (AI), posterior wall sign (PWS), and anterior center edge angle (ACEA). Intraoperative fluoroscopy was adjusted to account for pelvic inclination. The fluoroscopic GRID was utilized in all cases (Phantom MSK Hip Preservation, OrthoGrid LLC, Salt Lake City, UT). Intraoperative fluoroscopic measurements were compared to preoperative and postoperative standing radiographs at 6 weeks using linear regression applied in MINITAB. Results. All pre and post-correction measurements demonstrated excellent agreement within an average difference of 1.2 and 0.9 degrees (deg) respectively (p<0.01). Agreement between post-correction fluoroscopic GRID measurements and 6-week postoperative radiographs was: average difference for LCEA −0.4 deg (range −5 to 8 deg, SD 3.4), −0.9 deg for ACEA (range −16 to 7 deg, SD 5.1), and 0.3 deg for AI (range −8 to 6 deg, SD 3.3) (all p<.01). The PWS agreement was 93%. There was a tendency for fluoroscopic GRID measurements to underestimate acetabular coverage by less than 1 degree. Conclusion. Our study validated the use of a novel intraoperative fluoroscopic tool that accounts for fluoroscopic distortion and permits real-time measurements of PAO fragment correction that correlate accurately with postoperative evaluation. We believe that this tool adds value by giving surgeons reliable quantitative measurements of correction without interfering with surgical work-flow. For any tables or figures, please contact the authors directly


The Bone & Joint Journal
Vol. 103-B, Issue 9 | Pages 1479 - 1487
1 Sep 2021
Davis ET Pagkalos J Kopjar B

Aims. The aim of our study was to investigate the effect of asymmetric crosslinked polyethylene liner use on the risk of revision of cementless and hybrid total hip arthroplasties (THAs). Methods. We undertook a registry study combining the National Joint Registry dataset with polyethylene manufacturing characteristics as supplied by the manufacturers. The primary endpoint was revision for any reason. We performed further analyses on other reasons including instability, aseptic loosening, wear, and liner dissociation. The primary analytic approach was Cox proportional hazard regression. Results. A total of 213,146 THAs were included in the analysis. Overall, 2,997 revisions were recorded, 1,569 in THAs with a flat liner and 1,428 in THAs using an asymmetric liner. Flat liner THAs had a higher risk of revision for any reason than asymmetric liner THAs when implanted through a Hardinge/anterolateral approach (hazard ratio (HR) 1.169, 95% confidence interval (CI) 1.022 to 1.337) and through a posterior approach (HR 1.122, 95% CI 1.108 to 1.346). There was no increased risk of revision for aseptic loosening when asymmetric liners were used for any surgical approach. A separate analysis of the three most frequently used crosslinked polyethylene liners was in agreement with this finding. When analyzing THAs with flat liners only, THAs implanted through a Hardinge/anterolateral approach were associated with a reduced risk of revision for instability compared to posterior approach THAs (HR 0.561 (95% CI 0.446 to 0.706)). When analyzing THAs with an asymmetric liner, there was no significant difference in the risk of revision for instability between the two approaches (HR 0.838 (95% CI 0.633 to 1.110)). Conclusion. For THAs implanted through the posterior approach, the use of asymmetric liners reduces the risk of revision for instability and revision for any reason. In THAs implanted through a Hardinge/anterolateral approach, the use of an asymmetric liner was associated with a reduced risk of revision. The effect on revision for instability was less pronounced than in the posterior approach. Cite this article: Bone Joint J 2021;103-B(9):1479–1487


The Bone & Joint Journal
Vol. 96-B, Issue 11 | Pages 1472 - 1477
1 Nov 2014
Vioreanu MH Parry MC Haddad FS Duncan CP

The Unified Classification System (UCS) emphasises the key principles in the assessment and management of peri-prosthetic fractures complicating partial or total joint replacement. We tested the inter- and intra-observer agreement for the UCS as applied to the pelvis and femur using 20 examples of peri-prosthetic fracture in 17 patients. Each subtype of the UCS was represented by at least one case. Specialist orthopaedic surgeons (experts) and orthopaedic residents (pre-experts) assessed reliability on two separate occasions. For the pelvis, the UCS showed inter-observer agreement of 0.837 (95% confidence intervals (CI) 0.798 to 0.876) for the experts and 0.728 (95% CI 0.689 to 0.767) for the pre-experts. The intra-observer agreement for the experts was 0.861 (95% CI 0.760 to 0.963) and 0.803 (95% 0.688 to 0.918) for the pre-experts. For the femur, the UCS showed an inter-observer kappa value of 0.805 (95% CI 0.765 to 0.845) for the experts and a value of 0.732 (95% CI 0.690 to 0.773) for the pre-experts. The intra-observer agreement was 0.920 (95% CI 0.867 to 0.973) for the experts, and 0.772 (95% CI 0.652 to 0.892) for the pre-experts. This corresponds to a substantial and ‘almost perfect’ inter- and intra-observer agreement for the UCS for peri-prosthetic fractures of the pelvis and femur. We hope that unifying the terminology of these injuries will assist in their assessment, treatment and outcome. Cite this article: Bone Joint J 2014;96-B:1472–7


The Bone & Joint Journal
Vol. 101-B, Issue 1_Supple_A | Pages 11 - 18
1 Jan 2019
Kayani B Konan S Thakrar RR Huq SS Haddad FS

Objectives. The primary objective of this study was to compare accuracy in restoring the native centre of hip rotation in patients undergoing conventional manual total hip arthroplasty (THA) versus robotic-arm assisted THA. Secondary objectives were to determine differences between these treatment techniques for THA in achieving the planned combined offset, component inclination, component version, and leg-length correction. Materials and Methods. This prospective cohort study included 50 patients undergoing conventional manual THA and 25 patients receiving robotic-arm assisted THA. Patients undergoing conventional manual THA and robotic-arm assisted THA were well matched for age (mean age, 69.4 years (. sd. 5.2) vs 67.5 years (. sd. 5.8) (p = 0.25); body mass index (27.4 kg/m. 2. (. sd. 2.1) vs 26.9 kg/m. 2. (. sd. 2.2); p = 0.39); and laterality of surgery (right = 28, left = 22 vs right = 12, left = 13; p = 0.78). All operative procedures were undertaken by a single surgeon using the posterior approach. Two independent blinded observers recorded all radiological outcomes of interest using plain radiographs. Results. The correlation coefficient was 0.92 (95% confidence interval (CI) 0.88 to 0.95) for intraobserver agreement and 0.88 (95% CI 0.82 to 0.94) for interobserver agreement in all study outcomes. Robotic THA was associated with improved accuracy in restoring the native horizontal (p < 0.001) and vertical (p < 0.001) centres of rotation, and improved preservation of the patient’s native combined offset (p < 0.001) compared with conventional THA. Robotic THA improved accuracy in positioning of the acetabular component within the combined safe zones of inclination and anteversion described by Lewinnek et al (p = 0.02) and Callanan et al (p = 0.01) compared with conventional THA. There was no difference between the two treatment groups in achieving the planned leg-length correction (p = 0.10). Conclusion. Robotic-arm assisted THA was associated with improved accuracy in restoring the native centre of rotation, better preservation of the combined offset, and more precise acetabular component positioning within the safe zones of inclination and anteversion compared with conventional manual THA


The Bone & Joint Journal
Vol. 98-B, Issue 2 | Pages 179 - 186
1 Feb 2016
Berber R Skinner J Board T Kendoff D Eskelinen A Kwon Y Padgett DE Hart A

Aims. There are many guidelines that help direct the management of patients with metal-on-metal (MOM) hip arthroplasties. We have undertaken a study to compare the management of patients with MOM hip arthroplasties in different countries. . Methods. Six international tertiary referral orthopaedic centres were invited to participate by organising a multi-disciplinary team (MDT) meeting, consisting of two or more revision hip arthroplasty surgeons and a musculoskeletal radiologist. A full clinical dataset including history, blood tests and imaging for ten patients was sent to each unit, for discussion and treatment planning. Differences in the interpretation of findings, management decisions and rationale for decisions were compared using quantitative and qualitative methods. Results. Overall agreement between the orthopaedic centres and the recommended treatment plans for the ten patients with MOM hip implants was moderate (kappa = 0.6). Full agreement was seen in a third of cases, however split decisions were also seen in a third of cases. Units differed in their interpretation of the significance of the investigation findings and put varying emphasis on serial changes, in the presence of symptoms. Discussion. In conclusion, the management of raised or rising blood metal ions, cystic pseudotumours and peri-acetabular osteolysis led to inconsistency in the agreement between centres. Coordinated international guidance and MDT panel discussions are recommended to improve consensus in decision making. Take home message: A lack of evidence and the subsequent variation in regulator guidance leads to differences in opinions, the clinical impact of which can be reduced through a multi-disciplinary team approach to managing patients with MOM hip implants. Cite this article: Bone Joint J 2016;98-B:179–86