Advertisement for orthosearch.org.uk
Results 1 - 20 of 37
Results per page:
Bone & Joint Research
Vol. 12, Issue 10 | Pages 636 - 643
10 Oct 2023
Hamilton V Sheikh S Szczepanska A Maskell N Hamilton F Reid JP Bzdek BR Murray JRD

Aims. Orthopaedic surgery uses many varied instruments with high-speed, high-impact, thermal energy and sometimes heavy instruments, all of which potentially result in aerosolization of contaminated blood, tissue, and bone, raising concerns for clinicians’ health. This study quantifies the aerosol exposure by measuring the number and size distribution of the particles reaching the lead surgeon during key orthopaedic operations. Methods. The aerosol yield from 17 orthopaedic open surgeries (on the knee, hip, and shoulder) was recorded at the position of the lead surgeon using an Aerodynamic Particle Sizer (APS; 0.5 to 20 μm diameter particles) sampling at 1 s time resolution. Through timestamping, detected aerosol was attributed to specific procedures. Results. Diathermy (electrocautery) and oscillating bone saw use had a high aerosol yield (> 100 particles detected per s) consistent with high exposure to aerosol in the respirable range (< 5 µm) for the lead surgeon. Pulsed lavage, reaming, osteotome use, and jig application/removal were medium aerosol yield (10 to 100 particles s. -1. ). However, pulsed lavage aerosol was largely attributed to the saline jet, osteotome use was always brief, and jig application/removal had a large variability in the associated aerosol yield. Suctioning (with/without saline irrigation) had a low aerosol yield (< 10 particles s. -1. ). Most surprisingly, other high-speed procedures, such as drilling and screwing, had low aerosol yields. Conclusion. This work suggests that additional precautions should be recommended for diathermy and bone sawing, such as enhanced personal protective equipment or the use of suction devices to reduce exposure. Cite this article: Bone Joint Res 2023;12(10):636–643


Bone & Joint Research
Vol. 9, Issue 4 | Pages 200 - 201
1 Apr 2020
Simpson AHRW Dall G Haas JG


Bone & Joint Open
Vol. 1, Issue 4 | Pages 74 - 79
24 Apr 2020
Baldock TE Bolam SM Gao R Zhu MF Rosenfeldt MPJ Young SW Munro JT Monk AP

Aim. The coronavirus disease 2019 (COVID-19) pandemic presents significant challenges to healthcare systems globally. Orthopaedic surgeons are at risk of contracting COVID-19 due to their close contact with patients in both outpatient and theatre environments. The aim of this review was to perform a literature review, including articles of other coronaviruses, to formulate guidelines for orthopaedic healthcare staff. Methods. A search of Medline, EMBASE, the Cochrane Library, World Health Organization (WHO), and Centers for Disease Control and Prevention (CDC) databases was performed encompassing a variety of terms including ‘coronavirus’, ‘covid-19’, ‘orthopaedic’, ‘personal protective environment’ and ‘PPE’. Online database searches identified 354 articles. Articles were included if they studied any of the other coronaviruses or if the basic science could potentially applied to COVID-19 (i.e. use of an inactivated virus with a similar diameter to COVID-19). Two reviewers independently identified and screened articles based on the titles and abstracts. 274 were subsequently excluded, with 80 full-text articles retrieved and assessed for eligibility. Of these, 66 were excluded as they compared personal protection equipment to no personal protection equipment or referred to prevention measures in the context of bacterial infections. Results. There is a paucity of high quality evidence surrounding COVID-19. This review collates evidence from previous coronavirus outbreaks to put forward recommendations for orthopaedic surgeons during the COVID-19 pandemic. The key findings have been summarized and interpreted for application to the orthopaedic operative setting. Conclusion. For COVID-19 positive patients, minimum suggested PPE includes N95 respirator, goggles, face shield, gown, double gloves, and surgical balaclava. Space suits not advised. Be trained in the correct technique of donning and doffing PPE. Use negative pressure theatres if available. Minimize aerosolization and its effects (smoke evacuation and no pulse lavage). Minimize further unnecessary patient-staff contact (dissolvable sutures, clear dressings, split casts)


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 3 | Pages 436 - 439
1 Apr 2003
Nogler M Lass-Flörl C Wimmer C Mayr E Bach C Ogon M

Instruments used in surgery which rotate or vibrate at a high frequency can produce potentially contaminated aerosols. Such tools are in use in cemented hip revision arthroplasties. We aimed to measure the extent of the environmental and body contamination caused by an ultrasound device and a high-speed cutter. On a human cadaver we carried out a complete surgical procedure including draping and simulated blood flow contaminated with Staphylococcus aureus (ATCC 12600). After cemented total hip arthroplasty, we undertook repeated extractions of cement using either an ultrasound device or a high-speed cutter. Surveillance cultures detected any environmental and body contamination of the surgical team. Environmental contamination was present in an area of 6 x 8 m for both devices. The concentration of contamination was lower for the ultrasound device. Both the ultrasound and the high-speed cutter contaminated all members of the surgical team. The devices tested produced aerosols which covered the whole operating theatre and all personnel present during the procedure. In contaminated and infected patients, infectious agents may be present in these aerosols. We therefore recommend the introduction of effective measures to control infection and thorough disinfection of the operating theatre after such procedures


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_10 | Pages 27 - 27
1 Oct 2020
Byrd JWT
Full Access

Introduction. With resumption of non-urgent surgery in May 2020, standard anesthesia for hip arthroscopy switched from general with endotracheal intubation (GA) to spinal (SA) in response to COVID-19 implications; reducing potential aerosolized exposure for patient and staff and reducing consumption of personal protective equipment (PPE). There are no studies that compare the attributes for these two anesthesia methods for hip arthroscopy; and thus, this was viewed as an opportunity to perform a comparative observational study on SA to a recent matched group of GA. Methods. Beginning in May 2020, SA became the standard for hip arthroscopy. GA was used if the patient refused SA or had a history of previous lumbar spinal surgery, or body mass index (BMI) greater than 35. SA patients were carefully matched for age, gender and procedure to a recent previous GA population and compared for recovery room (RR) length of stay, entry and discharge visual analog scores (VAS), morphine mg equivalent (MME) usage, and untoward events. Additionally, SA and GA cases performed since May 2020 were compared for the length of time from entry to the operating room (OR) until the surgeon was able to perform an examination under anesthesia (EUA). Results. Statistical analysis determined that these groups are too small (46 in each group) to establish significant differences, but the authors felt that an opportunity to explore this, based on a recent change out of necessity (COVID-!9), was worth presenting as a novel study to compare two accepted methods of anesthesia for hip arthroscopy. SA patients required fewer regional blocks (7 vs 1) and needed less narcotics (99 vs 153). As a potential advantage of SA, continued investigation to see if this reaches statistical significance is meaningful. SA patients did spend more time in the PACU (136 vs 133); and had more problems with urinary retention, requiring catheterization (5 vs 0); but most of these occurred early in the experience and was corrected by having the patient void immediately prior to transfer to the OR and avoiding anticholinergic medications. SA seemed to add only slightly to the length of time until the surgeon could perform an EUA and begin positioning for the procedure (9 vs 8). Conclusion. Hip arthroscopy can be effectively performed with either GA or SA. Of particular interest with further studies will be whether choice of anesthesia affects early postoperative rehabilitation


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_15 | Pages 95 - 95
1 Nov 2018
Gibney R Matthyssen S Steele J Patterson J Zakaria N Ferraris E
Full Access

Collagen is a key component of the extracellular matrix in a variety of tissues and hence is widely used in tissue engineering research, yet collagen has had limited uptake in the field of 3D printing. In this study we successfully adapted an existing electronic printing method, aerosol jet printing (AJP), to print high resolution 3D constructs of recombinant collagen type III (RHCIII). Circular samples with a diameter of 4.5mm and 288 layers thick, or a diameter of 6.5mm and 400 layers thick were printed on glass cover slips with print lines of 60µm. Attenuated Total Reflectance Fourier-Transorm Infa-red (ATR-FTIR) spectroscopy performed on the 4 of the printed samples and dried non-printed RHCIII samples showed that no denaturation had occurred due to the printing process. Printed samples were crosslinked using EDC [N-(3-Dimethylaminopropyl)-N′-ethylcarbodiimide hydrochloride, Sigma Aldrich] to improve their stability and mechanical strength. Differential scanning calorimetry (DSC) performed showed a marked difference in the denaturation temperature between crosslinked printed samples and fibrillar non-printed samples and nano-indentation showed that the construct was relatively stiff. Previous results with similar samples have shown that mesenchymal stem cells (MSCs) align with and travel parallel to print direction. Results obtained from these samples show signs that they might be applied in other areas such as bone tissue engineering


Bone & Joint 360
Vol. 13, Issue 1 | Pages 41 - 43
1 Feb 2024

The February 2024 Research Roundup360 looks at: If you use a surgical helmet, you should seal your gown-glove interface; The use of iodophor-impregnated drapes in patients with iodine-related allergies: a case series and review of the literature; Location of the ovaries in children and efficacy of gonadal shielding in hip and pelvis radiography; Prehospital tranexamic acid administration does not improve outcomes in severe trauma patients; Silver-coated distal femur megaprosthesis in chronic infections with severe bone loss: a multicentre case series.


Bone & Joint Open
Vol. 5, Issue 10 | Pages 894 - 897
16 Oct 2024
Stoneham A Poon P Hirner M Frampton C Gao R

Aims

Body exhaust suits or surgical helmet systems (colloquially, ‘space suits’) are frequently used in many forms of arthroplasty, with the aim of providing personal protection to surgeons and, perhaps, reducing periprosthetic joint infections, although this has not consistently been borne out in systematic reviews and registry studies. To date, no large-scale study has investigated whether this is applicable to shoulder arthroplasty. We used the New Zealand Joint Registry to assess whether the use of surgical helmet systems was associated with lower all-cause revision or revision for deep infection in primary shoulder arthroplasties.

Methods

We analyzed 16,000 shoulder arthroplasties (hemiarthroplasties, anatomical, and reverse geometry prostheses) recorded on the New Zealand Joint Registry from its inception in 2000 to the present day. We assessed patient factors including age, BMI, sex, and American Society of Anesthesiologists (ASA) grade, as well as whether or not the operation took place in a laminar flow operating theatre.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 89 - 89
1 Jul 2014
Arntz P Kuhli M Reimers N Steckel H
Full Access

Summary Statement. This work features a new approach to overcome drawbacks of commercial calcium phosphate cements in terms of application by on-site preparation and bone ingrowth by introduction of macropores in the material using a hydrofluoroalkane based aerosol foam. Introduction. The application of calcium phosphate bone cements (CPCs) into a void for example of an osteoporotic bone is very difficult as the cement paste is made outside the application site and subsequently applied into the damaged bone. A common drawback of especially apatitic cements is a very low resorption rate due to small pore size Therefore different approaches have been described to add macropores into the cement. 2. , leading to bone ingrowth and tissue penetration. The aim of this project is the use of two separate formulations in pressurised systems – a suspension and an emulsion – which can be mixed in a specially developed device and can be applied easily and efficiently into a bone directly during surgery leading to a self-hardening macro porous CPC foam. The intention is to fill voids in osteoporotic bones to ensure stability for implants like e.g. screws for femur neck fractures. An increased stability for implants can allow the possibility of a less invasive femur neck preserving therapy in contrast to a femur neck replacement. Other indications for such foam (i.e. kyphoplasty) are under evaluation. Methods. As suggested above two separate formulations for the components are developed to prevent premature hardening. Hydrofluoroalkanes were preferred as propellants to propane, butane or isobutane, due to their superior safety profile. The hardener component was formulated as propellant-in-water emulsion. Several parentally approved emulsifiers (e.g. Poloxamer 188) were tested in view of solubility at the given salt and binder concentration. The stability of resulting emulsions in pressurised containers, the corresponding foams as well as the foam expansion volume was analyzed. Porous hydroxyapatite is formed after addition of tetra-calciumphosphate, di-calciumphosphate dihydrate and tri-sodiumcitrat dehydrate incorporated in the suspension component. To overcome quick sedimentation of these solids, particle size was reduced by dry or non-aqueous wet milling, respectively. Changes in particle size distribution and enthalpy changes during processes were analyzed. Hardening properties of both components were tested particularly with regard to compressive strength. In order to apply the components, a suitable application system was developed and the hardened product analyzed using x-ray diffraction. Results. The optimised Ca. 2+. /(PO. 4. ). 3−. component is a submicron-sized suspension in a mixture of ethanol and HFA 134a. The development of the suspension led to new knowledge with regard to milling effects on the Ca. 2+. /(PO. 4. ). 3−. components. The optimised hardener component contains an aqueous solution of sodium phosphates, Povidone 90 and Poloxamer 188 emulsified in HFA 227. Both components are formulated in pressurised cans. Discussion/Conclusion. A two component bone foam for stabilisation in osteoporotic bones including a new mixing / application system, which allows actuation of the components and leads to a hardening process that results in hydroxyapatite in a suitable test setup, was developed. The new application system. Further steps i.e. proof of concept (in-vitro and in-vivo) are being taken


Bone & Joint Open
Vol. 2, Issue 9 | Pages 752 - 756
1 Sep 2021
Kabariti R Green N Turner R

Aims

During the COVID-19 pandemic, drilling has been classified as an aerosol-generating procedure. However, there is limited evidence on the effects of bone drilling on splatter generation. Our aim was to quantify the effect of drilling on splatter generation within the orthopaedic operative setting.

Methods

This study was performed using a Stryker System 7 dual rotating drill at full speed. Two fluid mediums (Videne (Solution 1) and Fluorescein (Solution 2)) were used to simulate drill splatter conditions. Drilling occurred at saw bone level (0 cm) and at different heights (20 cm, 50 cm, and 100 cm) above the target to simulate the surgeon ‘working arm length’, with and without using a drill guide. The furthest droplets were marked and the droplet displacement was measured in cm. A surgical microscope was used to detect microscopic droplets.


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_III | Pages 224 - 225
1 Sep 2005
Green D Leveque I Walsh D Partridge K Howard D Mann S Oreffo R
Full Access

Introduction: The clinical need for a biodegradable material with broad application is evidenced by the fact that tissue loss as a result of injury or disease provides reduced quality of life for many at significant socio-economic cost. The development of simple biodegradable materials, with broad applicability and tissue/ cell specificity has to date proved elusive. Natural biopolymers such as alginate and chitosan are structural biomaterials of increasing significance to tissue repair and regeneration due to their potential for fabrication, design and efficient, environmentally benign synthesis. We describe the development of innovative microcapsule scaffolds based on chitosan and alginate that can be tailored to a range of cell types for a variety of tissues. Methods: Semi-permeable polysaccharide microcapsules were produced by a one-step method, in which the deposition of a semi-permeable alginate/chitosan membrane around droplets of sodium alginate was coupled with in-situ precipitation of amorphous calcium phosphate as described by Leveque et al (2002). *. A variety of human cell types including mesenchymal stem cells, osteoprogenitors selected using the STRO-1 antibody by magnetically activated cell separation (MACS), osteoprogenitors transfected with adenovirus expressing Green Fluorescent Protein (GFP) and chondrocytes were mixed with sodium alginate and encapsulated within alginate/chitosan and calcium phosphate. Results: Hybrid spheres (750–10,000um) were generated encapsulating primary human osteoprogenitor cells, STRO-1 selected osteoprogenitors and AdGFP transfected osteoprogenitors. Encapsulated cells remain viable inside the polysaccharide microcapsules for 2 weeks as shown by positive alkaline phosphatase staining of encapsulated cells. Cells expressing GFP were observed within microspheres indicating the e ability to deliver cells/factors as well as the potential for gene therapy. Encapsulation and delivery of active BMP-2 was confirmed using the promyoblast cell line C2C12 known to be exquisitely sensitive to BMP-2. Nucleation of calcium phosphate occurred within the polysaccharide membrane and could be controlled by the phosphate concentration in the alginate droplets to produce hybrid microcapsules with enhanced mechanical strength. Thin walled capsules were shown to split and degrade in culture within 2–4 days releasing viable osteoprogenitor cells indicating the ability to manipulate the mechanical integrity and to programme degradation of the microspheres. Finally we have shown that aggregation of the microspheres into extended frameworks can be achieved using a designed droplet/vapour aerosol system resulting in foams of aggregated beads. Discussion and Conclusion: A variety of human skeletal cells have been encapsulated within polysaccharide/ calcium phosphate microspheres and extended frameworks with specifiable dimensions. These composite scaffolds offer stable mechanical and chemical biomimetic environments conducive to normal cell function. Natural polysaccharides are also highly amenable to complexation with a range of bioactive molecules and consequently offer tremendous potential in tissue engineering and regeneration of hard and soft tissues


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_10 | Pages 1 - 1
1 Oct 2020
Clohisy J Haddad FS
Full Access

The unparalleled events of the year 2020 continue to evolve and challenge the worldwide community on a daily basis. The COVID-19 pandemic has had a major impact on all aspects of our lives, and has caused major morbidity and mortality around the globe. The impact of COVID-19 on the practice of orthopedic surgery has been substantial with practice shutdowns, elective surgery restrictions, heightened utilization of telemedicine platforms and implementation of precautionary measures for in-person clinic visits. During this transition period the scholarly and educational pursuits of academic surgeons have been de-emphasized as the more immediate demands of clinical practice survivorship have been the priority. This unavoidable focus on clinical practice has heightened the importance of orthopedic subspecialty societies in maintaining an appropriate level of attention on research and educational activities. Under the outstanding presidential leadership of Robert Barrack, MD, The Hip Society adapted to the profound challenges of 2020, and maintained strong leadership in the realms of education and research. The recent 2020 summer meeting of the Hip Society was a testimonial to the resilience and dedication of the Society members to ongoing innovation in research and education. Due to travel and social distancing restrictions the 2020 summer meeting was transitioned from an in-person to a virtual meeting format. Dr Barrack and Program Chair Dr John Clohisy assisted with oversight of the meeting, while Olga Foley and Cynthia Garcia ensured the success of the meeting with remarkable planning and organization. These collaborative efforts resulted in an organized, well-attended, high level scientific meeting with engaging discussion and a remarkable virtual conference environment. The Bone & Joint Journal is very pleased to partner with The Hip Society to publish the proceedings of this very unique virtual meeting. The Hip Society is based in the United States and membership is granted to select individuals for leadership accomplishments in education and research related to hip disease. The Society is focused on the mission of advancing the knowledge and treatment of hip disorders to improve the lives of patients. The vision of the Hip Society is to lead in the discovery and dissemination of knowledge related to disorders of the hip. The annual closed meeting is one of the most important events of the society as this gathering highlights timely, controversial and novel research contributions from the membership. The top research papers from The Hip Society meeting will be published and made available to the wider orthopedic community in The Bone & Joint Journal. This partnership with The Bone & Joint Journal enhances the mission and vision of The Hip Society by international dissemination of the meeting proceedings. Given the far-reaching circulation of The Bone & Joint Journal the highest quality work is available to an expanding body of surgeons, associated healthcare providers and patients. Ultimately, this facilitates the overarching Hip Society goal of improving the lives of our patients. The 2020 virtual Hip Society meeting was characterized by outstanding member attendance, high quality paper presentations and robust discussion sessions. The meeting was held over two days and encompassed 58 open paper presentations divided into ten sessions with moderated discussions after each session. All papers will be presented in this issue in abstract form, while selected full papers passing our rigorous peer review process will be available online and in The Bone & Joint Journal in a dedicated supplement in 2021. The first session of the meeting focused on issues related to complex primary THA and osteonecrosis of the femoral head. Dr Gross presented on the conversion of hip fusion to THA in 28 patents at a mean 7 years. He reported a high clinical success rate, yet complications of heterotopic ossification and neurologic injury were relatively common. Consideration of heterotopic ossification prophylaxis and the selective use of a constrained liner were recommended. Dr Pagnano summarized the use of various contemporary porous acetabular components in 38 hips in the setting of prior pelvic radiation. The mean follow-up was 5 years and 10 year survivorship was 100% with all implants radiographically fixed. Dr Bolognesi's study demonstrated that THA in solid organ transplant patients is associated with higher risk for facility placement, transfusions and readmissions. This patient population also has increased mortality risk (4.3% risk at 1 year) especially lung transplant patients. The second group of papers focused on femoral head osteonecrosis. Dr Iorio presented single center data demonstrating that CT scan was a useful adjunct for diagnosis in the staging work-up for cancer, yet was not useful for ARCO staging and treatment decision-making. On the basic science side, Dr Goodman utilized a rabbit model of steroid-induced femoral head osteonecrosis to determine that immunomodulation with IL-4 has the potential to improve bone healing after core decompression. The session was concluded by Dr Nelson's study of ceramic-on-ceramic THA in 108 osteonecrosis patients. The median 12 year results were outstanding with marked increases in PROs, maintenance of high activity levels, and a 3.7% revision rate. In the second session attention was directed to THA instability and spinopelvic mobility. Dr Sierra presented a machine learning algorithm for THA dislocation risk. Two modifiable variables (anterior/lateral approach, elevated liner) were most influential in minimizing dislocation risk. Dr Taunton's study demonstrated a deep learning artificial intelligence model derived from postoperative radiographs to predict THA dislocation risk. High sensitivity and negative predictive value suggest that this model may be helpful in assessing postoperative dislocation risk. In reviewing a large single-center, multiple surgeon cohort of 2,831 DAA procedures, Dr Moskal noted a very low dislocation rate (0.45%) at minimum 2 years. Importantly, spinopelvic pathology or prior spinal instrumentation was not associated with an increased dislocation risk (0.30%). Dr Huo and colleagues analyzed pelvic tilt during functional gait in patients with acetabular dysplasia. They detected variable pelvic tilt on different surfaces with the data suggesting that patients with more anterior pelvic tilt while standing tend to have greater compensatory posterior pelvic tilt during gait. Dr Lamontagne reported on the sagittal and axial spinomobility in patients with hip OA, and highlighted reductions in pelvic tilt, pelvic-femoral-angle, lumbar lordosis and seated maximal trunk rotation when compared to controls. Dr Dennis showed that differences in spinopelvic mobility may explain the variable accuracy of acetabular version measurements on the cross-table lateral radiographs. Dr Gwo-Chin presented on a comprehensive functional analysis of 1,592 patients undergoing THA and observed that spinopelvic abnormalities are not infrequent (14%) in THA patients. Consistent with these findings Dr Murphy and collaborators identified a low prevalence of previous spinal instrumentation (1.5%), yet a high prevalence of spine stiffness (27.6%) in 149 patients undergoing THA. Session three highlighted various aspects of treating hip disease in young patients. Dr Peters investigated the need for subsequent hip arthroscopy in 272 patients treated with an isolated PAO. Only 4.8% of these patients required subsequent arthroscopy calling into question the routine use of combined arthroscopy and PAO. Three papers addressed questions related to THA in young patients. Dr Berend's study of 2532 hips demonstrated that high activity level was not associated with an increased risk of midterm aseptic or all cause failure. Dr Nunley presented on 43 young patients with an average age of 52 years treated with a cementless stem and modular dual mobility articulation. Stress shielding was minimal and no concerning metal ion release detected. Dr Garvin summarized minimum 15 year data of THA with highly cross-linked polyethylene in patient less than 50 years. These hips performed exceptionally well with no mechanical loosening or radiographic osteolysis. Dr Engh examined 10 year results of the Birmingham Hip Resurfacing implant and reported a 92.9 % overall survivorship, with males less than 55 years achieving a 98.3% survivorship. The session was concluded by long-term data on the Conserve Plus hip resurfacing arthroplasty. Dr Amstutz presented an impressive dataset depicting an 83.1% 20 year survivorship for this early resurfacing cohort. Direct anterior approach total hip arthroplasty was the focus of session four. Dr Meneghini reported on the anesthesia and surgical times of direct anterior and posterior approaches from a large healthcare system database. These data suggested longer OR and surgical times for the DAA both in the inpatient and ASC environments. Dr Clohisy introduced the technique and early outcomes of lateral decubitus position DAA. In a learning curve experience of 257 hips. 96% of acetabular components were in the Lewinneck safe zone, the aseptic revision rate was 0.9% and there were no dislocations. Dr Beaule analyzed femoral stem cement mantle with the DAA and posterior approaches by comparing two matched cohorts. Stem alignment and cement mantle quality were equivalent with both approaches. Similarly, Dr Emerson demonstrated technical feasibility and fewer cemented femoral stem failures when compared to cementless stems in a series of 360 DAAs THAs. The final paper of the session presented by Dr Hamilton examined the impact of surgical approach on dislocation after isolated head and liner exchange. Neither the posterior nor the anterior approach was superior in reducing the dislocation rate for these high dislocation risk procedures. The fifth session explored contemporary topics related to anesthesia and pain management. Dr Byrd opened the session with a comparative study evaluating general versus spinal anesthesia for hip arthroscopy. This preliminary study was provoked by the desire to minimize aerosolized exposure early in the COVID-19 pandemic by transitioning to spinal anesthesia. Both anesthetic methods were effective. Dr Austin presented a randomized, double-blind controlled trial comparing spinal anesthetic with mepivacaine, hyperbaric bupivacaine and isobaric bupivacaine. Mepivacaine patients ambulated earlier and were more likely to be discharged the same day. Dr Mont provided a very timely study on the effects of “cannabis use disorder” and THA outcomes. This administrative database study of 44,154 patients revealed this disorder to be associated with longer hospital stays, increased complications rates and higher costs. Dr Bedair investigated whether a highly porous acetabular component submerged in an analgesic solution could enhance perioperative pain management. Interestingly, this novel strategy was associated with a reduction of postoperative pain scores and opioid consumption in 100 experimental patients compared to 100 controls. The concluding paper of the session by Dr Della Valle examined whether decreased discharge opioids led to increased postoperative opioid refills. A large single-center study of 19,428 patients detected a slight increase (5%) in opioid refills but a reduction in total refill morphine milligram equivalents. The final, sixth session of day one considered various challenging aspects of revision hip arthroplasty. Dr Nam started the session with review of preliminary results from a randomized control trial comparing closed incision negative-pressure therapy with a silver-impregnated dressing for wound management in 113 hips undergoing revision arthroplasty. Unlike previous reports, the negative pressure therapy was associated with a higher reoperation rate for wound-related complications. Dr Bostrom highlighted the potential clinical impact of basic biological interventions by establishing the presence of Neutrophil Extracellular Traps (NETS) in fibrotic tissue from human aseptic loosening specimens and in a murine model of unstable tibial implantation. NET inhibition in the murine model prevented the expected tibial implant osseointegration failure. Dr Lombardi presented early 3.3 year clinical results of a highly porous Ti6al4v acetabular component in complex primary and revision arthroplasty. Survivorship for aseptic loosening was 96.6 % and 95.3% for the primary and revision cases, respectively. Dr Schwarzkopf and colleagues explored the impact of time to revision arthroplasty on clinical outcomes. Analysis of 188 revision cases revealed early revisions (less than 2 years from primary) were associated with worse outcomes, longer hospitalizations and higher reoperation rates. Mid-term results for modular dual mobility implants in revision arthroplasty were reviewed by Dr Lachiewicz who reported on 126 hips at a mean 5.5 years. 11% of hips dislocated and the 6 year survival was 91%. An outer head diameter of 48mm or greater was associated with a lower risk of dislocation. Dr Berry concluded the session by discussing the outcomes of treating the challenging problem of interprosthetic femur fractures. A single-center study of 77 cases treated over 32 years demonstrated a 79% success rate free of reoperation at 2 years with 95% of patients being ambulatory. The second day commenced with the seventh session evaluating recent strategies to improve short-term THA outcomes. Dr Bozic and colleagues investigated the association of quality measure public reporting with hip/knee replacement outcomes. Annual trend data from 2010–2011 and 2016–2017 indicate that hospital-level complication and readmission rates decease after the start of public reporting, yet it is difficult to prove a direct effect. Dr Slover reviewed his institutions experience with the Comprehensive Care for Joint Replacement (CJR) model and emphasized that lower CJR target prices make it increasingly difficult for programs to meet target price thresholds. Cost saving strategies including same day discharge and reduction of home health services may result in smaller losses of positive margins. Dr Barsoum reported on the influence of patient and procedure-related risk factors of length of stay after THA. Patient-related risk factors provided substantial predictive value yet procedure-related risk factors (hospital site and surgical approach) remain the main drivers of predicting length of stay. Dr Hozack reviewed an impressive, single surgeon cohort of 3,977 DAA THAs and analyzed adverse events and 90 day perioperative outcomes. Simultaneous bilateral DAA THA was comparable with unilateral or staged bilateral procedures in regards to complications, readmission rate and home discharge rate but with an increased risk of transfusion. To examine the risk of complications with outpatient joint arthroplasty, Dr Della Valle performed a single-surgeon matched cohort analysis comparing outpatient and inpatient hip and knee arthroplasties. Outpatient procedures were not associated with an increased risk of any postoperative complications and actually experienced fewer emergency department visits. The eighth session covered various contemporary challenges in hip arthroplasty care. Dr Griffin began the session with an analysis of the timing of complications associated with two-stage exchange procedures for periprosthetic joint infection (PJI). Of the 189 hips included, 41.6% had a complication and the mortality was 14.1% at 2.5 years, highlighting the morbidity of this treatment method. Dr Fehring provided data assessing the fate of two-stage reimplantation after failed debridement, antibiotics and implant retention (DAIR) for a prosthetic hip infection. This analysis of 114 hips yielded concerning results demonstrating a 42.9% treatment failure of patients treated with a previous DAIR compared to a 12.3% failure rate in patients treated with an initial 2-stage procedure. Dr Jacobs reviewed the analysis of 106 femoral heads with severe corrosion and identified a chemically dominated etching process termed “column damage” to be a detrimental damage mode within CoCr femoral heads that is directly linked to banding within its microstructure. These data indicate that implant alloy microstructure must be optimized to minimize the release of fretting-corrosion products. Simon Mears presented retrospective data from 184 THAs with a dual modular femoral stem. A subgroup of hips with a modular, cobalt chromium femoral neck had a pseudotumor visualized in 15% with only 55% of these having elevated CoCr levels. These findings may support the use of routine follow-up MARS MRI for modular CoCr femoral neck prostheses. The final two studies explored timely issues related to viral illness and hip surgery. Dr Browne analyzed three large administrative databases to elucidate whether patients are at increased risk for viral illnesses following total joint replacement. The incidence of postoperative influenza after total joint replacement was not increased compared to patients not undergoing total joint replacement surgery suggesting that arthroplasty procedures may not heighten the risk of viral illness. In the final paper of the session Dr Haddad presented important data regarding perioperative complications in coronavirus positive patients undergoing surgical treatment of femoral neck fractures. In this multicenter cohort study from the United Kingdom 82 coronavirus positive patients were shown to have longer hospital stays, more critical care unit admissions, higher risk of perioperative complications and an increased mortality compared to 340 coronavirus negative patients. The eighth session had two papers on alternative femoral stem designs and three presentations more focused on femoral fracture treatments. Dr Mihalko focused on the European and US experiences with the Metha femoral neck retaining stem. The US experience mirrored the encouraging results from Europe with a 94% all cause femoral survivorship and a 99.1% femoral aseptic loosening survivorship at 5 years. Dr Kraay summarized dual energy x-ray absorptiometry (DEXA) evaluation of 16 low modulus composite femoral components at long-term follow-up of a mean 22 years. The bone mineral density associated with the implant increased in Gruen zones 2–6 and showed limited decreases in zones 1 and 7. These data support the concept that a low modulus femoral stem may more effectively load the proximal femur. Dr Springer provided data from the American Joint Replacement Registry (AJRR) and by evaluating outcomes of exact matched cohorts of 17,138 patients treated with cementless or cemented femoral implants for femoral neck fractures. Cemented implants were associated with marked reduction in early revision and periprosthetic fractures. However, cemented fixation was associated with an increased mortality at 90 days and 1 year. Additional data from the AJRR was presented by Dr Huddleston who investigated the risk factors for revision surgery after arthroplasty in a cohort of 75,333 femoral neck fractures. THA when compared to hemiarthroplasty was associated with higher early and overall revision rates. Cementless femoral fixation and increased age were also associated with higher rates of any revision. Both of these studies from the AJRR suggest that further consideration should be given to femoral fixation preferences in the femoral neck fracture population. Dr Vail summarized his institution's experience with an interdisciplinary hip fracture protocol for patients undergoing arthroplasty for acute femoral neck fractures. His study compared 157 cases prior to protocol implementation with 114 patients treated after the protocol was established. The impact of the interdisciplinary protocol was impressive as evidenced by a reduced time to operative treatment, length of stay, complication rate and one-year mortality. All being achieved without an increase in readmissions or facility discharges. The final session of the meeting addressed innovations in perioperative care of THA patients. Dr Barrack started the session with an interesting study examining the feasibility and patient preferences regarding telemedicine. A cross-sectional telephone survey of 163 arthroplasty patients indicated that 88% of patients use the internet and 94% own a device capable of videoconferencing. Nevertheless, only 18% of patients preferred a video visit over an in-person clinic visit due to concerns of inferior care. Dr Barnes quantified preoperative optimization work in 100 arthroplasty patients by using EMR activity logs and determined the surgical team spends an average 75 minutes per case on preoperative work activities. Dr Duwelius reported the early outcomes of primary THA with a smartphone-based exercise and educational platform compared to standard of care controls. A randomized control trial design with 365 patients demonstrated similar outcomes and non-inferiority of the smartphone platform relative to complications, readmissions, emergency room/urgent care visits. The association of controlled substance use with THA outcomes was assessed by Dr Higuera Rueda. A quantitative assessment using the NarxCare score identified 300 and above as a score associated with adverse outcomes after THA. Dr Macaulay reviewed data from a large retrospective study of 1,825 THAs indicating that discontinuation of intermittent pneumatic compression devices does not increase the risk of venous thromboembolism in standard risk patients being treated with 81mg ASA BID as prophylaxis. Dr Antoniou presented the final paper of the meeting investigating potential changes in patient health status as an indication for surgery over time. Data from this large systematic review of the literature found patients undergoing THA at similar health status to the past with no influence form patient age, gender, year of enrollment or geographic region. As summarized above, the 2020 virtual Hip Society Summer Meeting was rich in scientific content, productive discussion and a collaborative spirit. This collective body of work will result in impactful scientific contributions and will serve as a foundation for future innovation and advancements in the treatment of hip disease


Bone & Joint Open
Vol. 2, Issue 8 | Pages 661 - 670
19 Aug 2021
Ajayi B Trompeter AJ Umarji S Saha P Arnander M Lui DF

Aims

The new COVID-19 variant was reported by the authorities of the UK to the World Health Organization (WHO) on 14 December 2020. We aim to describe the clinical characteristics and nosocomial infection rates in major trauma and orthopaedic patients comparing the first and second wave of COVID-19 infection.

Methods

A retrospective analysis of a prospectively collected trauma database was reviewed at a level 1 major trauma centre from 1 December 2020 to 18 February 2021 looking at demographics, clinical characteristics, and nosocomial infections and compared to our previously published first wave data (26 January 2020 to 14 April 2020).


Bone & Joint Open
Vol. 1, Issue 6 | Pages 309 - 315
23 Jun 2020
Mueller M Boettner F Karczewski D Janz V Felix S Kramer A Wassilew GI

Aims

The worldwide COVID-19 pandemic is directly impacting the field of orthopaedic surgery and traumatology with postponed operations, changed status of planned elective surgeries and acute emergencies in patients with unknown infection status. To this point, Germany's COVID-19 infection numbers and death rate have been lower than those of many other nations.

Methods

This article summarizes the current regimen used in the field of orthopaedics in Germany during the COVID-19 pandemic. Internal university clinic guidelines, latest research results, expert consensus, and clinical experiences were combined in this article guideline.


Bone & Joint Open
Vol. 1, Issue 6 | Pages 222 - 228
9 Jun 2020
Liow MHL Tay KXK Yeo NEM Tay DKJ Goh SK Koh JSB Howe TS Tan AHC

The coronavirus disease 2019 (COVID-19) pandemic has led to unprecedented challenges to healthcare systems worldwide. Orthopaedic departments have adopted business continuity models and guidelines for essential and non-essential surgeries to preserve hospital resources as well as protect patients and staff. These guidelines broadly encompass reduction of ambulatory care with a move towards telemedicine, redeployment of orthopaedic surgeons/residents to the frontline battle against COVID-19, continuation of education and research through web-based means, and cancellation of non-essential elective procedures. However, if containment of COVID-19 community spread is achieved, resumption of elective orthopaedic procedures and transition plans to return to normalcy must be considered for orthopaedic departments. The COVID-19 pandemic also presents a moral dilemma to the orthopaedic surgeon considering elective procedures. What is the best treatment for our patients and how does the fear of COVID-19 influence the risk-benefit discussion during a pandemic? Surgeons must deliberate the fine balance between elective surgery for a patient’s wellbeing versus risks to the operating team and utilization of precious hospital resources. Attrition of healthcare workers or Orthopaedic surgeons from restarting elective procedures prematurely or in an unsafe manner may render us ill-equipped to handle the second wave of infections. This highlights the need to develop effective screening protocols or preoperative COVID-19 testing before elective procedures in high-risk, elderly individuals with comorbidities. Alternatively, high-risk individuals should be postponed until the risk of nosocomial COVID-19 infection is minimal. In addition, given the higher mortality and perioperative morbidity of patients with COVID-19 undergoing surgery, the decision to operate must be carefully deliberated. As we ramp-up elective services and get “back to business” as orthopaedic surgeons, we have to be constantly mindful to proceed in a cautious and calibrated fashion, delivering the best care, while maintaining utmost vigilance to prevent the resurgence of COVID-19 during this critical transition period.

Cite this article: Bone Joint Open 2020;1-6:222–228.


Bone & Joint Open
Vol. 1, Issue 5 | Pages 88 - 92
1 May 2020
Hua W Zhang Y Wu X Gao Y Yang C

During the pandemic of COVID-19, some patients with COVID-19 may need emergency surgeries. As spine surgeons, it is our responsibility to ensure appropriate treatment to the patients with COVID-19 and spinal diseases. A protocol for spinal surgery and related management on patients with COVID-19 has been reviewed. Patient preparation for emergency surgeries, indications, and contraindications of emergency surgeries, operating room preparation, infection control precautions and personal protective equipments (PPE), anesthesia management, intraoperative procedures, postoperative management, medical waste disposal, and surveillance of healthcare workers were reviewed. It should be safe for surgeons with PPE of protection level 2 to perform spinal surgeries on patients with COVID-19. Standardized and careful surgical procedures should be necessary to reduce the exposure to COVID-19.


Bone & Joint Open
Vol. 1, Issue 7 | Pages 420 - 423
15 Jul 2020
Wallace CN Kontoghiorghe C Kayani B Chang JS Haddad FS

The coronavirus 2019 (COVID-19) global pandemic has had a significant impact on trauma and orthopaedic (T&O) departments worldwide. To manage the peak of the epidemic, orthopaedic staff were redeployed to frontline medical care; these roles included managing minor injury units, forming a “proning” team, and assisting in the intensive care unit (ICU). In addition, outpatient clinics were restructured to facilitate virtual consultations, elective procedures were cancelled, and inpatient hospital admissions minimized to reduce nosocomial COVID-19 infections. Urgent operations for fractures, infection and tumours went ahead but required strict planning to ensure patient safety. Orthopaedic training has also been significantly impacted during this period. This article discusses the impact of COVID-19 on T&O in the UK and highlights key lessons learned that may help to proactively prepare for the next global pandemic.

Cite this article: Bone Joint Open 2020;1-7:420–423.


Bone & Joint Open
Vol. 1, Issue 5 | Pages 144 - 151
21 May 2020
Hussain ZB Shoman H Yau PWP Thevendran G Randelli F Zhang M Kocher MS Norrish A Khanduja V

Aims

The COVID-19 pandemic presents an unprecedented burden on global healthcare systems, and existing infrastructures must adapt and evolve to meet the challenge. With health systems reliant on the health of their workforce, the importance of protection against disease transmission in healthcare workers (HCWs) is clear. This study collated responses from several countries, provided by clinicians familiar with practice in each location, to identify areas of best practice and policy so as to build consensus of those measures that might reduce the risk of transmission of COVID-19 to HCWs at work.

Methods

A cross-sectional descriptive survey was designed with ten open and closed questions and sent to a representative sample. The sample was selected on a convenience basis of 27 senior surgeons, members of an international surgical society, who were all frontline workers in the COVID-19 pandemic. This study was reported according to the Standards for Reporting Qualitative Research (SRQR) checklist.


The Bone & Joint Journal
Vol. 103-B, Issue 4 | Pages 597 - 599
1 Apr 2021
Kader DF Oussedik S Kader N Haddad FS


Bone & Joint Research
Vol. 10, Issue 3 | Pages 188 - 191
1 Mar 2021
Nicholson T Scott A Newton Ede M Jones SW