Lateral clavicular physeal injuries in adolescents
are frequently misinterpreted as acromioclavicular dislocations. There
are currently no clear guidelines for the management of these relatively
rare injuries. Non-operative treatment can result in a cosmetic
deformity, warranting resection of the non-remodelled original lateral
clavicle. However, fixation with Kirschner (K)-wires may be associated
with infection and/or prominent metalwork. We report our experience
with a small series of such cases. Between October 2008 and October 2011 five patients with lateral
clavicular physeal fractures (types III, IV and V) presented to
our unit. There were four boys and one girl with a mean age of 12.8
years (9 to 14). Four fractures were significantly displaced and
treated operatively using a tension band suture technique. One grade
III fracture was treated conservatively. The mean follow-up was
26 months (6 to 42). All patients made an uncomplicated recovery. The mean time to
discharge was three months. The QuickDASH score at follow-up was
0 for each patient. No patient developed subsequent growth disturbances. We advocate the surgical treatment of significantly displaced
Grade IV and V fractures to avoid cosmetic deformity. A tension
band suture technique avoids the problems of retained metalwork
and the need for a secondary procedure. Excellent clinical and radiological
results were seen in all our patients. Cite this article:
In a prospective randomised study we compared the results of arthroscopic subacromial bursectomy alone with debridement of the subacromial bursa followed by acromioplasty. A total of 57 patients with a mean age of 47 years (31 to 60) suffering from primary subacromial impingement without a rupture of the rotator cuff who had failed previous conservative treatment were entered into the trial. The type of
Radiographs of the shoulders of 84 asymptomatic individuals aged between 40 and 83 years were evaluated to determine changes in 23 specific areas. Two fellowship-trained orthopaedic radiologists graded each area on a scale of 0 to II (normal 0, mild changes I, advanced changes II). Logistic regression analysis indicated age to be a significant predictor of change (p <
0.05) for sclerosis of the medial
We hypothesised that a large acromial cover with
an upwardly tilted glenoid fossa would be associated with degenerative
rotator cuff tears (RCTs), and conversely, that a short acromion
with an inferiorly inclined glenoid would be associated with glenohumeral
osteoarthritis (OA). This hypothesis was tested using a new radiological parameter,
the critical shoulder angle (CSA), which combines the measurements
of inclination of the glenoid and the lateral extension of the acromion
(the
In 100 patients the fulcrum axis which is the line connecting the anterior tip of the coracoid and the posterolateral angle of the
A new technique of shoulder fusion is presented using a posterior approach. After removal of the articular cartilage, a Rush pin is introduced from the spine of the scapula, through the glenoid into the medullary canal of the humerus. This is supplemented by tension-band wiring from the
Os acromiale is a rare anatomical abnormality and treatment is controversial. Our retrospective study analyses the outcome of excision, acromioplasty and bony fusion of the os acromiale when it is associated with a tear of the rotator cuff. After a mean follow-up of 41 months, 33 patients were radiologically and clinically assessed using the Constant score. The surgical procedure was to repair the rotator cuff together with excision of the os acromiale in six patients, acromioplasty in five, and fusion in 22. Of the 22 attempted fusions seven failed radiologically. The Constant scores were 82%, 81%, 81% and 84% for patients who had excision, acromioplasty, successful fusion and unsuccessful fusion respectively. There were no statistically significant differences. We conclude that a small mobile os acromiale can be resected, a large stable os acromiale treated by acromioplasty and a large unstable os acromiale by fusion to the
We studied the stability of cemented all-polyethylene keeled glenoid components by radiostereometric analysis (RSA) in 16 shoulders which had received a total shoulder replacement. There were 14 women (one bilateral) and one man with a mean age of 64 years. The diagnosis was osteoarthritis in eight and rheumatoid arthritis in seven. Two of the shoulders were excluded from the RSA study because of loosening of the tantalum markers. Three tantalum markers were inserted in the glenoid socket, two in the coracoid process and two in the
Spinal accessory nerve palsy leads to painful disability of the shoulder, carrying an uncertain prognosis. We reviewed the long-term outcome in 16 patients who were treated for pain, weakness of active elevation and asymmetry of the shoulder and the neck due to chronic paralysis of the trapezius muscle, as a result of nerve palsy. Of four patients who were treated conservatively, none regained satisfactory function, although two became pain-free. The other 12 patients were treated operatively with transfer of the levator scapulae to the
Most brachial plexus palsies are due to trauma, often resulting from motorcycle accidents. When nerve repair and physiotherapy are unsuccessful, muscle transfer may be considered. Paralysis of the deltoid and supraspinatus muscles can be addressed by transfer of the trapezius. Between March 1994 and June 1997 we treated 38 patients with brachial plexus palsy by trapezius transfer and reviewed 31 of these (7 women, 24 men) after a mean follow-up of 23.8 months (12 to 39), reporting the clinical and radiological results and subjective assessment. The mean age of the patients was 29 years (18 to 46). The operations had been performed according to the method of Saha described in 1967, involving transfer of the
Rotator cuff (RC) tears are common musculoskeletal injuries which often require surgical intervention. Noninvasive pulsed electromagnetic field (PEMF) devices have been approved for treatment of long-bone fracture nonunions and as an adjunct to lumbar and cervical spine fusion surgery. This study aimed to assess the effect of continuous PEMF on postoperative RC healing in a rat RC repair model. A total of 30 Wistar rats underwent acute bilateral supraspinatus tear and repair. A miniaturized electromagnetic device (MED) was implanted at the right shoulder and generated focused PEMF therapy. The animals’ left shoulders served as controls. Biomechanical, histological, and bone properties were assessed at three and six weeks.Aims
Methods
A total of 92 patients with symptoms for over
six months due to subacromial impingement of the shoulder, who were
being treated with physiotherapy, were included in this study. While
continuing with physiotherapy they waited a further six months for
surgery. They were divided into three groups based on the following
four clinical and radiological criteria: temporary benefit following
steroid injection, pain in the mid-arc of abduction, a consistently positive
Hawkins test and radiological evidence of impingement. Group A fulfilled
all four criteria, group B three criteria and group C two criteria.
A total of nine patients improved while waiting for surgery and
were excluded, leaving 83 who underwent arthroscopic subacromial
decompression (SAD). The new Oxford shoulder score was recorded
pre-operatively and at three and 12 months post-operatively. A total of 51 patients (group A) had a significant improvement
in the mean shoulder score from 18 (13 to 22) pre-operatively to
38 (35 to 42) at three months (p <
0.001). The mean score in
this group was significantly better than in group B (21 patients)
and C (11 patients) at this time. At one year patients in all groups
showed improvement in scores, but patients in group A had a higher
mean score (p = 0.01). At one year patients in groups A and B did
better than those in group C (p = 0.01). Arthroscopic SAD is a beneficial intervention in selected patients.
The four criteria could help identify patients in whom it is likely
to be most effective.
Surgical repair of posterosuperior rotator cuff
tears has a poorer outcome and a higher rate of failure compared
with repairs of supraspinatus tears. In this prospective cohort
study 28 consecutive patients with an irreparable posterosuperior
rotator cuff tear after failed conservative or surgical treatment
underwent teres major tendon transfer. Their mean age was 60 years
(48 to 71) and the mean follow-up was 25 months (12 to 80). The
mean active abduction improved from 79° (0° to 150°) pre-operatively
to 105° (20° to 180°) post-operatively (p = 0.011). The mean active
external rotation in 90° abduction improved from 25° (0° to 70°)
pre-operatively to 55° (0° to 90°) post-operatively (p <
0.001).
The mean Constant score improved from 43 (18 to 78) pre-operatively
to 65 (30 to 86) post-operatively (p <
0.001). The median post-operative
VAS (0 to 100) for pain decreased from 63 (0 to 96) pre-operatively to
5 (0 to 56) post-operatively (p <
0.001). In conclusion, teres major transfer effectively restores function
and relieves pain in patients with irreparable posterosuperior rotator
cuff tears and leads to an overall clinical improvement in a relatively
young and active patient group with limited treatment options. Cite this article:
We report the use of the reverse shoulder prosthesis in the revision of a failed shoulder hemiarthroplasty in 19 shoulders in 18 patients (7 men, 11 women) with severe pain and loss of function. The primary procedure had been undertaken for glenohumeral arthritis associated with severe rotator cuff deficiency. Statistically significant improvements were seen in pain and functional outcome. After a mean follow-up of 44 months (24 to 89), mean forward flexion improved by 26.4° and mean abduction improved by 35°. There were six prosthesis-related complications in six shoulders (32%), five of which had severe bone loss of the glenoid, proximal humerus or both. Three shoulders (16%) had non-prosthesis related complications. The use of the reverse shoulder prosthesis provides improvement in pain and function for patients with failure of a hemiarthroplasty for glenohumeral arthritis and rotator cuff deficiency. However, high rates of complications were associated with glenoid and proximal humeral bone loss.
Between March 1994 and June 2003, 80 patients with brachial plexus palsy underwent a trapezius transfer. There were 11 women and 69 men with a mean age of 31 years (18 to 69). Before operation a full evaluation of muscle function in the affected arm was carried out. A completely flail arm was found in 37 patients (46%). Some peripheral function in the elbow and hand was seen in 43 (54%). No patient had full active movement of the elbow in combination with adequate function of the hand. Patients were followed up for a mean of 2.4 years (0.8 to 8). We performed the operations according to Saha’s technique, with a modification in the last 22 cases. We demonstrated a difference in the results according to the pre-operative status of the muscles and the operative technique. The transfer resulted in an increase of function in all patients and in 74 (95%) a decrease in multidirectional instability of the shoulder. The mean increase in active abduction was from 6° (0 to 45) to 34° (5 to 90) at the last review. The mean forward flexion increased from 12° (0 to 85) to 30° (5 to 90). Abduction (41°) and especially forward flexion (43°) were greater when some residual function of the pectoralis major remained (n = 32). The best results were achieved in those patients with most pre-operative power of the biceps, coracobrachialis and triceps muscles (n = 7), with a mean of 42° of abduction and 56° of forward flexion. Active abduction (28°) and forward flexion (19°) were much less in completely flail shoulders (n = 34). Comparison of the 19 patients with the Saha technique and the 15 with the modified procedure, all with complete paralysis, showed the latter operation to be superior in improving shoulder stability. In all cases a decrease in instability was achieved and inferior subluxation was abolished. The results after trapezius transfer depend on the pre-operative pattern of paralysis and the operative technique. Better results can be achieved in patients who have some function of the biceps, coracobrachialis, pectoralis major and triceps muscles compared with those who have a complete palsy. A simple modification of the operation ensures a decrease in joint instability and an increase in function.
We describe the results of surgical treatment in a prospective study of 183 consecutive cases of subluxation (101) and dislocation (82) of the shoulder secondary to obstetric brachial plexus palsy between 1995 and 2000. Neurological recovery was rated ‘good’ or ‘useful’ in all children, whose lesions fell into groups 1, 2 or 3 of the Narakas classification. The mean age at operation was 47 months (3 to 204). The mean follow-up was 40 months (24 to 124). The mean gain in function was 3.6 levels (9.4 to 13) using the Mallet score and 2 (2.1 to 4.1) on the Gilbert score. The mean active global range of shoulder movement was increased by 73°; the mean range of active lateral rotation by 58° and that of supination of the forearm by 51°. Active medial rotation was decreased by a mean of 10°. There were 20 failures. The functional outcome is related to the severity of the neurological lesion, the duration of the dislocation and onset of deformity.
The pathogenesis of rotator cuff disease (RCD) is complex and
not fully understood. This systematic review set out to summarise
the histological and molecular changes that occur throughout the
spectrum of RCD. We conducted a systematic review of the scientific literature
with specific inclusion and exclusion criteria.Introduction
Methods
There have been only a few small studies of patients
with an infected shoulder replacement treated with a single-stage
exchange procedure. We retrospectively reviewed 35 patients (19 men
and 16 women) with a peri-prosthetic infection of the shoulder who
were treated in this way. A total of 26 were available for clinical
examination; three had died, two were lost to follow-up and four
patients had undergone revision surgery. The mean follow-up time was
4.7 years (1.1 to 13.25), with an infection-free survival of 94%. The organisms most commonly isolated intra-operatively were Single-stage exchange is a successful and practical treatment
for patients with peri-prosthetic infection of the shoulder. Cite this article:
After establishing anatomical feasibility, functional reconstruction to replace the anterolateral part of the deltoid was performed in 20 consecutive patients with irreversible deltoid paralysis using the sternoclavicular portion of the pectoralis major muscle. The indication for reconstruction was deltoid deficiency combined with massive rotator cuff tear in 11 patients, brachial plexus palsy in seven, and an isolated axillary nerve lesion in two. All patients were followed clinically and radiologically for a mean of 70 months (24 to 125). The mean gender-adjusted Constant score increased from 28% (15% to 54%) to 51% (19% to 83%). Forward elevation improved by a mean of 37°, abduction by 30° and external rotation by 9°. The pectoralis inverse plasty may be used as a salvage procedure in irreversible deltoid deficiency, providing subjectively satisfying results. Active forward elevation and abduction can be significantly improved.
The aim of this study was to determine the functional outcome and rate of re-tears following mini-open repair of symptomatic large and massive tears of the rotator cuff using a two-row technique. The 24 patients included in the study were assessed prospectively before and at a mean of 27 months (18 to 53) after surgery using the Constant and the Oxford Shoulder scores. Ultrasound examination was carried out at follow-up to determine the integrity of the repair. Patient satisfaction was assessed using a simple questionnaire. The mean Constant score improved significantly from 36 before to 68 after operation (p <
0.0001) and the mean Oxford Shoulder score from 39 to 20 (p <
0.0001). Four of the 24 patients (17%) had a re-tear diagnosed by ultrasound. A total of 21 patients (87.5%) were satisfied with the outcome of their surgery. The repair remained intact in 20 patients (83%). However, the small number of re-tears (four patients) in the study did not allow sufficient analysis to show a difference in outcome in relation to the integrity of the repair.