Introduction. This study aims to evaluate the effect of using different types of fixator on the quality of callus and complications during distraction osteogenesis in patients with
Introduction. To evaluate the results of correction of knee deformities based on deformity analysis in
Lengthening of the humerus is now an established
technique. We compared the complications of humeral lengthening
with those of femoral lengthening and investigated whether or not
the callus formation in the humerus proceeds at a higher rate than
that in the femur. A total of 24 humeral and 24 femoral lengthenings
were performed on 12 patients with
The effect of lower extremity lengthening on physeal growth is still controversial. We aim to compare data of the patients who had bilateral simultaneous femur and tibia lengthening with the patients who underwent the lengthening surgery separately for the femur and tibia at the end of completed skeletal maturation in terms of the effect of physeal growth. Twenty-six patients were included who operated in our clinic between 1995 and 2015 for limb lengthening. Fourteen patients with bilateral lengthening of the femur and tibia at the same time were named as simultaneous lengthening (SL). Twelve patients with bilateral lengthening of the femur and then bilateral tibia lengthening seperately were named consecutively lengthening (CL). All patients were followed until completion of growth. The physeal arrest was measured using predicted length (investigated with the multiplier method), the total amount of lengthening and final length.Introduction
Materials and Methods
Introduction. Angular deformity in the lower extremities can result in pain, gait disturbance, deformity and joint degeneration. Guided growth modulation uses the tension band principle with the goal of treatment being to normalise the mechanical axis. To assess the success of this procedure we reviewed our results in an attempt to identify patients who may not benefit from this simple and elegant procedure. Materials and Methods. We reviewed the surgical records and imaging in our tertiary children's hospital to identify all patients who had guided growth surgery since 2007. We noted the patient demographics, diagnosis, peri-operative experience and outcome. All patients were followed until skeletal maturity or until metalwork was removed. Results. 173 patients with 192 legs were assessed for eligibility. Six were excluded due to inadequate follow-up or loss of records. Of the 186 treated legs meeting criteria for final assessment 19.8% were unsuccessful, the other 80.2% were deemed successful at final follow up. Complications included infection and metal-work failure. Those with a pre-treatment diagnosis of idiopathic genu valgum/ varum had a success rate of 83.6%. Conclusions. In our hands, guided growth had an 80-percent success rate when all diagnosis were considered. Those procedures that were unlikely to be successful included growth disturbances due to mucopolysaccharide storage disease, Blounts disease and
As an alternative to external fixators, intramedullary lengthening nails (ILNs) can be employed for distraction osteogenesis. While previous studies have demonstrated that typical complications of external devices, such as soft-tissue tethering, and pin site infection can be avoided with ILNs, there is a lack of studies that exclusively investigated tibial distraction osteogenesis with motorized ILNs inserted via an antegrade approach. A total of 58 patients (median age 17 years (interquartile range (IQR) 15 to 21)) treated by unilateral tibial distraction osteogenesis for a median leg length discrepancy of 41 mm (IQR 34 to 53), and nine patients with disproportionate short stature treated by bilateral simultaneous tibial distraction osteogenesis, with magnetically controlled motorized ILNs inserted via an antegrade approach, were retrospectively analyzed. The median follow-up was 37 months (IQR 30 to 51). Outcome measurements were accuracy, precision, reliability, bone healing, complications, and patient-reported outcome assessed by the Limb Deformity-Scoliosis Research Society Score (LD-SRS-30).Aims
Methods
The STRYDE nail is an evolution of the PRECICE Intramedullary Limb Lengthening System, with unique features regarding its composition. It is designed for load bearing throughout treatment in order to improve patient experience and outcomes and allow for simultaneous bilateral lower limb lengthening. The literature published to date is limited regarding outcomes and potential problems. We report on our early experience and raise awareness for the potential of adverse effects from this device. This is a retrospective review of prospective data collected on all patients treated in our institution using this implant. We report the demographics, nail accuracy, reliability, consolidation index, and cases where concerning clinical and radiological findings were encountered. There were 14 STRYDE nails implanted in nine patients (three male and six female) between June 2019 and September 2020. Mean age at surgery was 33 years (14 to 65). Five patients underwent bilateral lengthening (two femoral and three tibial) and four patients unilateral femoral lengthening for multiple aetiologies.Aims
Methods
Patients with skeletal dysplasia are prone to developing advanced degenerative knee disease requiring total knee replacement (TKR) at a younger age than the general population. TKR in this unique group of patients is a technically demanding procedure due to the bone deformity, flexion contracture, generalised hypotonia and ligamentous laxity. We set out to retrospectively review the outcome of 11 TKR's performed in eight patients with skeletal dysplasia at our institution using the SMILES custom-made rotating-hinge total knee system. There were 3 males and 5 females with mean age 57 years (range, 41–79 years), mean height 138 cm (range, 122–155 cm) and mean weight 56 kg (range, 40–102 kg). Preoperative diagnoses included
The aim of this study was to present the first retrieval analysis findings of PRECICE STRYDE intermedullary nails removed from patients, providing useful information in the post-market surveillance of these recently introduced devices. We collected ten nails removed from six patients, together with patient clinical data and plain radiograph imaging. We performed macro- and microscopic analysis of all surfaces and graded the presence of corrosion using validated semiquantitative scoring methods. We determined the elemental composition of surface debris using energy dispersive x-ray spectroscopy (EDS) and used metrology analysis to characterize the surface adjacent to the extendable junctions.Aims
Methods
External fixation is widely used in orthopaedic
and trauma surgery. Infections around pin or wire sites, which are usually
localised, non-invasive, and are easily managed, are common. Occasionally,
more serious invasive complications such as necrotising fasciitis
(NF) and toxic shock syndrome (TSS) may occur. We retrospectively reviewed all patients who underwent external
fixation between 1997 and 2012 in our limb lengthening and reconstruction
programme. A total of eight patients (seven female and one male)
with a mean age of 20 years (5 to 45) in which pin/wire track infections
became limb- or life-threatening were identified. Of these, four
were due to TSS and four to NF. Their management is described. A
satisfactory outcome was obtained with early diagnosis and aggressive
medical and surgical treatment. Clinicians caring for patients who have external fixation and
in whom infection has developed should be aware of the possibility
of these more serious complications. Early diagnosis and aggressive
treatment are required in order to obtain a satisfactory outcome. Cite this article:
Computer hexapod assisted orthopaedic surgery (CHAOS), is a method
to achieve the intra-operative correction of long bone deformities
using a hexapod external fixator before definitive internal fixation
with minimally invasive stabilisation techniques. The aims of this study were to determine the reliability of this
method in a consecutive case series of patients undergoing femoral
deformity correction, with a minimum six-month follow-up, to assess
the complications and to define the ideal group of patients for
whom this treatment is appropriate. The medical records and radiographs of all patients who underwent
CHAOS for femoral deformity at our institution between 2005 and
2011 were retrospectively reviewed. Records were available for all
55 consecutive procedures undertaken in 49 patients with a mean
age of 35.6 years (10.9 to 75.3) at the time of surgery.Aims
Patients and Methods