As our understanding of hip function and disease improves, it is evident that the
The bicompartmental acetabulum is one of the morphological changes which may be seen in children with Legg-Calvé-Perthes’ disease. Three-dimensional CT and MRI were used to analyse the detailed morphology of the acetabulum with special reference to its inner surface, in 16 patients with Perthes’ disease and a bicompartmental acetabulum. The bicompartmental appearance was seen on the coronal plane image through the
Introduction: In severe Legg-Calve-Perthes (LCPD) disease with subluxated femoral head, the acetabulum sometimes takes a bicompartmental appearance. This study analyzed acetabular pathoanatomy using a 3-D CT program. Materials and Methods: A 3-D CT software program that affords the section of 2-D image in any plane was used to analyze the acetabular pathoanatomy, with specific reference to the morphology of the inner surface of the acetabulum. Thirteen children with the bicompartmental acetabulae (12 LCPD and 1 AVN subsequent to septic hip arthritis) were evaluated. Results: The anterior half of the acetabulum was concentric. The contour of the acetabular margin in the posterior half of the acetabulum consisted of two different arcs – an arc of the iliac acetabulum (superior) and the other arc of the
Acetabular dysplasia was produced in 24 immature white rabbits. A rotational acetabular osteotomy was then carried out and radiological and histological studies of the articular cartilage were made. In the hips which did not undergo osteotomy, radiographs at 26 weeks showed that residual subluxation remained and arthritic changes such as narrowing of the joint space or dislocation were still seen. However, in the operated group there was a remarkable increase in cover, but arthritic changes were not observed. After 24 weeks, the Mankin grading score in the operated group was significantly lower than that in the non-operated group. The latter hips showed an irregular surface of the cartilage, exfoliation and proliferation of synovial tissue. In those undergoing osteotomy, primary cloning of chondrocytes or hypercellularity was seen and at 24 weeks after operation and metaplasia of the cartilage in the fibrous tissue was observed in the boundary between the medial area of the acetabulum and the
Aims. Accurate positioning of the acetabular component is essential for achieving the best outcome in total hip arthroplasty (THA). However, the acetabular shape and anatomy in severe hip dysplasia (Crowe type IV hips) is different from that of arthritic hips. Positioning the acetabular component in the acetabulum of Crowe IV hips may be surgically challenging, and the usual surgical landmarks may be absent or difficult to identify. We analyzed the acetabular morphology of Crowe type IV hips using CT data to identify a landmark for the ideal placement of the centre of the acetabular component as assessed by morphometric geometrical analysis and its reliability. Patients and Methods. A total of 52 Crowe IV and 50 normal hips undergoing total hip arthroplasty were retrospectively identified. In this CT-based simulation study, the acetabular component was positioned at the true acetabulum with a radiographic inclination of 40° and anteversion of 20° (Figure 1). Acetabular shape and the position of the centre of the acetabular component were analyzed by morphometric geometrical analysis using the generalized Procrustes analysis (Figure 2). To describe major trends in shape variations within the sample, we performed a principal component analysis of partial warp variables (Figure 3). Results. The plot of the landmarks showed that the centre of the acetabular component of normal hips was positioned around the centre of the acetabulum and superior and slightly posterior on the
Introduction. Instability continues to be the number one reason for revision in primary total hip arthroplasty (THA). Commonly, impingement precedes dislocation, inducing a levering out the prosthetic head from the liner. Impingement can be prosthetic, bony or soft tissue, depending on component positioning and anatomy. The aim of this virtual study was to investigate whether bony or prosthetic impingement occurred first in well positioned THAs, with the hip placed in deep flexion and hyperextension. Methods. Twenty-three patients requiring THA were planned for a TriFit/Trinity ceramic-on-poly cementless construct using the OPS. TM. dynamic planning software (Corin, UK). The cups were sized to best fit the anatomy, medialised to sit on the
Introduction. The objective of this study was to compare the performance of the Explant Acetabular Cup Removal System (Zimmer), which has been the favored system for many surgeons during hip revision surgery, and the new EZout Powered Acetabular Revision System (Stryker). Methods. 54mm Stryker Trident® acetabular shells were inserted into the foam acetabula of 24 composite hemi-pelvises (Sawbones). The hemi-pelvises were mounted on a supporting apparatus enclosing three load cells. Strain gauges were placed on the hemipelvis, on the posterior and the anterior wall, and on the internal ischium in proximity to the
Introduction. Total hip arthroplasty (THA) is one of the most common orthopedic surgeries. The procedure is sophisticated and in addition to several factors affecting the outcomes such as patient's status, surgeon's expertise and implant type, using appropriate surgical tools is necessary. Acetabular component implantation necessitates the surgeon to ream the
Objectives. Few reports were shown about the position of the cup in total hip arthroplasty (THA) with CT-based navigation system. We use minimally invasive surgery (MIS) technique when we perform cementless THA and the correct settings of cups are sometimes difficult in MIS. So we use CT-based navigation system for put implants with correct angles and positions. We evaluated the depth of cup which was shown on intra-operative navigation system. Materials and Methods. We treated 30 hips in 29 patients (1 male and 28 females) by navigated THA. 21 osteoarthritis hips, 6 rheumatoid arthritis hips and 3 idiopathic osteonecrosis hips were performed THA with VectorVision Hip navigation system (BrainLAB). Implants were AMS HA cups and PerFix stems (Japan Medical Materials, Osaka). Appropriate angles and positions of cups were decided on the 3D model of pelvis before operation. According to the preoperative planning, we put the implants with navigation system. We correct the pelvic inclination angle and measured the depth of cups with 3D template software. Results. The average distance from the surface of the cup to the edge of medial wall of pelvis was 3.4mm (0.0–8.0mm) on the axial plane which include the center of femoral head on postoperative CT. The average distance from the surface of the cup to the edge of medial wall of pelvis was 6.4mm (1.5–15.0mm) on intraoperative navigation. The average error was 2.9mm (0.0–9.0mm). The cup positions of post operative CT were deeper than that of intraoperative navigation in twenty six hips (86%). Conclusions. The shallow setting of cups caused the instability of cups. Deep setting caused damage of
Introduction. Computer-assisted methods for acetabulum cup navigation have shown to be able to improve the accuracy of the procedure, but are time-consuming and difficult to use. The goal of this project was to develop an easy-to-use navigation technique, requiring minimal equipment for acetabular cup alignment. Material. A preoperative CT scan was obtained, a 3D model of the acetabulum was created, the pelvic plane determined and the cup orientation planned. A registration area, which included the accessible part of the
The treatment of osteochondritis dissecans after Legg-Calvé-Perthes’disease hasnot been clearly determined. It may be either by simple observation or surgical removal of the osteochondral fragment. We studied the evolution of the lesion in 13 children and reviewed 92 hips reported in the literature. In our patients ten showed a tendency towards spontaneous healing, one required drilling + grafting to obtain fusion, and in two there was separation into the joint. These loose bodies were in the
1. Prosthetic acetabular cups of the Charnley and McKee-Farrar designs were cemented into cadaveric pelves using different procedures for preparing the acetabulum. 2. The torsional moments needed to loosen these cups were measured. 3. The torsional moments so measured were found to be from about four to more than twenty times higher than the frictional moments measured in independent tests on the two designs of prosthesis. 4. It is argued that late looseness of the acetabular component after total hip replacement, in the absence of infection, seems most likely to be due to thermal damage to the bone occurring at the time of polymerisation of the cement, and to subsequent bone resorption. 5. Surgical preparation of the acetabulum should include removal of all the articular cartilage and cleaning of the
Objectives. Few reports were shown about the position of the cup in total hip arthroplasty (THA) with CT-based navigation system. We use minimally invasive surgery (MIS) technique when we perform cementless THA and the correct settings of cups are sometimes difficult in MIS. So we use CT-based navigation system for put implants with correct angles and positions. We evaluated the depth of cup which was shown on intra-operative navigation system. Materials and Methods. We treated 30 hips in 29 patients (1 male and 28 females) by navigated THA. 21 osteoarthritis hips, 6 rheumatoid arthritis hips and 3 idiopathic osteonecrosis hips were performed THA with VectorVision Hip 2.5.1 navigation system (BrainLAB). Implants were AMS HA cups and PerFix stems (Japan Medical Materials, Osaka). Appropriate angles and positions of cups were decided on the 3D model of pelvis before operation. According to the preoperative planning, we put the implants with navigation system. We correct the pelvic inclination angle and measured the depth of cups with 3D template software. Results. The average distance from the surface of the cup to the edge of medial wall of pelvis was 3.4mm (0.0-8.0mm) on the axial plane which include the center of femoral head on postoperative CT. The average distance from the surface of the cup to the edge of medial wall of pelvis was 6.4mm (1.5-15.0mm) on intraoperative navigation. The average error was 2.9mm (0.0-9.0mm). The cup positions of post operative CT were deeper than that of intraoperative navigation in twenty six hips (86%). Conclusions. The shallow setting of cups caused the instability of cups. Deep setting caused damage of
One potential limitation with uncemented, hemispherical metal-backed acetabular components is stress shielding of bony structures due to the mismatch in elastic modulus between the metal backing and the peri-prosthetic bone. A proposed substitute is a horseshoe-shaped acetabular component, which replicates the bony anatomy. One such device, the Cambridge cup, has shown successful clinical and radiological outcomes at five years follow-up (Brooks 2004, Field 2005). We conducted a study of the Cambridge cup from a biomechanical perspective, using validated, high-resolution computational models of the bilateral hip. Peri-prosthetic stress and strain fields associated with the Cambridge cup were compared to those for the natural hip and a reconstructed hip with a conventional metal-backed hemispherical cup during peak gait loading. We found that the hemispherical cup caused an unphysiologic distribution of bone stresses in the superior roof and unphysiologic strain transfer around the
The February 2023 Trauma Roundup360 looks at: Masquelet versus bone transport in infected nonunion of tibia; Hyperbaric Oxygen for Lower Limb Trauma (HOLLT): an international multicentre randomized clinical trial; Is the T-shaped acetabular fracture really a “T”?; What causes cut-out of proximal femur nail anti-rotation device in intertrochanteric fractures?; Is the common femoral artery at risk with percutaneous fragility pelvis fixation?; Anterior pelvic ring pattern predicts displacement in lateral compression fractures; Differences in age-related characteristics among elderly patients with hip fractures.
Femoroacetabular impingement (FAI) patients report exacerbation of hip pain in deep flexion. However, the exact impingement location in deep flexion is unknown. The aim was to investigate impingement-free maximal flexion, impingement location, and if cam deformity causes hip impingement in flexion in FAI patients. A retrospective study involving 24 patients (37 hips) with FAI and femoral retroversion (femoral version (FV) < 5° per Murphy method) was performed. All patients were symptomatic (mean age 28 years (SD 9)) and had anterior hip/groin pain and a positive anterior impingement test. Cam- and pincer-type subgroups were analyzed. Patients were compared to an asymptomatic control group (26 hips). All patients underwent pelvic CT scans to generate personalized CT-based 3D models and validated software for patient-specific impingement simulation (equidistant method).Aims
Methods
Introduction: Management of Ficat stage III and IV hip osteonecrosis remains a formidable challenge in regards to long term care. We report a case of a hemiresurfacing arthroplasty lasting 23 years in a patient who received the implant for osteonecrosis associated with corticosteroid use following kidney transplantation. In 1981, a moderately obese, 27-year-old man presented with bilateral osteonecrotic collapse of the femoral heads secondary to heavy immunosuppressive corticosteroid therapy associated with a kidney transplant. The patient had suffered a loss of both kidneys after a bout of severe nephritis that resulted in replacement with a cadaver kidney in 1979. A cemented THARIES (total hip articular replacement with internal eccentric shells) metal-on-polyethylene resurfacing (Zimmer, Warsaw, Indiana) was implanted in the right hip in 1981. At 3 years post-operatively, the patient complained of acute, exacerbated pain in his right hip. The THARIES components were removed for acetabular and femoral loosening and replaced with a total hip replacement. Surgery: The acetabular cartilage of the other hip was rated intraoperatively as Grade III (no or minimal acetabular cartilage involvement), and was deemed suitable for hemiresurfacing. A 50 millimeter custom cemented titanium shell (Zimmer, Warsaw, Indiana) was implanted using a lateral incision and a trans-trochanteric approach. The patient continued to be assessed by the surgeon on a regular basis, and returned to an active lifestyle while his kidney function continued to be regulated with corticosteroids and imoran. In 1989, eight years following hemiresurfacing, the left hip radiographs showed a reduced joint space, with further new bone in the
Developmental dysplasia of the hip is a condition in which the acetabulum provides insufficient coverage of the femoral head in the hip joint. This configuration gives poor biomechanical load distribution, with increased stress at the superior aspect of the joint surfaces, and can often lead to degenerative arthritis. Morphologically, the poor coverage may be due to an acetabulum that is too shallow or oriented in valgus. The dysplastic deformity can be treated surgically with a group of similar procedures, often labeled periacetabular osteotomies or rotational acetabular osteotomies. Each involves separating the acetabulum from the pelvis and fixating the fragment back to the pelvis in an orientation with increased coverage of the femoral head. This redistributes the biomechanical loads relative to acetabulum. Bone remodeling at the level of trabeculae is an accepted concept under research; however, it is unclear whether the hip undergoes gross morphology changes in response to changes in biomechanical loading. An understanding of the degree to which this remodeling occurs (if at all) may have an impact on surgical planning. In this retrospective study, computed tomography (CT) scans of 13 patients (2 male, 11 female, 40 ± 9 years of age) undergoing unilateral periacetabular osteotomies were examined; scans were taken both pre-operatively and at least a year post-operatively with an in-plane resolution of 0.55 mm and a slice thickness of 1.25 mm. Scans were segmented to produce triangulated meshes for the proximal femurs and the pelvis. These scans were manually processed to isolate the articular portions of the femoral heads and acetabulums, respectively; the fovea,
Rotational acetabular osteotomy (RAO) has been reported to be effective in improving symptoms and preventing osteoarthritis (OA) progression in patients with mild to severe develomental dysplasia of the hip (DDH). However, some patients develop secondary OA even when the preoperative joint space is normal; determining who will progress to OA is difficult. We evaluated whether the preoperative cartilage condition may predict OA progression following surgery using T2 mapping MRI. We reviewed 61 hips with early-stage OA in 61 patients who underwent RAO for DDH. They underwent preoperative and five-year postoperative radiological analysis of the hip. Those with a joint space narrowing of more than 1 mm were considered to have 'OA progression'. Preoperative assessment of articular cartilage was also performed using 3T MRI with the T2 mapping technique. The region of interest was defined as the weightbearing portion of the acetabulum and femoral head.Aims
Methods
We analyzed the acetabular morphology of Crowe type IV hips using CT data to identify a landmark for the ideal placement of the centre of the acetabular component, as assessed by morphometric geometrical analysis, and its reliability. A total of 52 Crowe IV hips (42 patients; seven male, 35 female; mean age 68.5 years (32 to 82)) and 50 normal hips (50 patients; eight male, 42 female; mean age 60.7 years (34 to 86)) undergoing total hip arthroplasty were retrospectively identified. In this CT-based simulation study, the acetabular component was positioned at the true acetabulum with a radiological inclination of 40° and anteversion of 20°. Acetabular shape and the position of the centre of the acetabular component were analyzed by morphometric geometrical analysis using the generalized Procrustes analysis.Aims
Patients and Methods