header advert
Results 1 - 30 of 30
Results per page:
Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_2 | Pages 5 - 5
1 Mar 2022
Clutton JM Razii N Chitnis SS Kakar R Morgan-Jones R
Full Access

Introduction

The burden of prosthetic joint infection (PJI) in total knee arthroplasty (TKA) has been rising in line with the number of primary operations performed. Current estimates suggest an infection rate of 1–2.4%. Two-stage revision has traditionally been considered the gold standard of treatment; however, some studies suggest comparable results can be achieved with single-stage procedures. The potential advantages include less time in hospital, a single anaesthetic, reduced costs, and greater patient satisfaction.

Methods

We reviewed data for 72 patients (47 males, 25 females), with a mean age of 71 years (range, 49 to 94), who underwent single-stage revision TKA for confirmed PJI between 2006 and 2016. A standardized debridement protocol was performed with immediate single-stage exchange. All cases were discussed preoperatively at multidisciplinary team (MDT) meetings, which included input from a senior musculoskeletal microbiologist. Patients were not excluded for previous revisions, culture-negative PJI, or the presence of a sinus.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_16 | Pages 23 - 23
1 Dec 2021
Boyd A Rodzen K Morton M Acheson J McIlhagger A Morgan R Tormey D Dave F Sherlock R Meenan B
Full Access

Abstract

INTRODUCTION

Polyetheretherketone (PEEK) is a high-performance thermoplastic polymer which has found increasing application in orthopaedic implant devices and has a lot of promise for ‘made-to-measure’ implants produced through additive manufacturing [1]. However, a key limitation of PEEK is that it is bioinert and there is a requirement to functionalise its surface to make the material osteoconductive to ensure a more rapid, improved and stable fixation, in vivo. One approach to solving this issue is to modify PEEK with bioactive materials, such as hydroxyapatite (HA).

OBJECTIVE

To 3D PEEK/HA composite materials using a Fused Filament Fabrication (FFF) approach to enhance the properties of the PEEK matrix.


Bone & Joint Open
Vol. 2, Issue 5 | Pages 305 - 313
3 May 2021
Razii N Clutton JM Kakar R Morgan-Jones R

Aims

Periprosthetic joint infection (PJI) is a devastating complication following total knee arthroplasty (TKA). Two-stage revision has traditionally been considered the gold standard of treatment for established infection, but increasing evidence is emerging in support of one-stage exchange for selected patients. The objective of this study was to determine the outcomes of single-stage revision TKA for PJI, with mid-term follow-up.

Methods

A total of 84 patients, with a mean age of 68 years (36 to 92), underwent single-stage revision TKA for confirmed PJI at a single institution between 2006 and 2016. In all, 37 patients (44%) were treated for an infected primary TKA, while the majority presented with infected revisions: 31 had undergone one previous revision (36.9%) and 16 had multiple prior revisions (19.1%). Contraindications to single-stage exchange included systemic sepsis, extensive bone or soft-tissue loss, extensor mechanism failure, or if primary wound closure was unlikely to be achievable. Patients were not excluded for culture-negative PJI or the presence of a sinus.


Bone & Joint Research
Vol. 9, Issue 6 | Pages 311 - 313
1 Jun 2020
Tsang SJ Morgan-Jones R Simpson AHRW


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_3 | Pages 4 - 4
1 Apr 2018
Western L Logishetty K Morgan R Cobb J Auvinet E
Full Access

Background

Accurate implant orientation is associated with improved outcomes after artificial joint replacement. We investigated if a novel augmented-reality (AR) platform (with live feedback) could train novice surgeons to orientate an acetabular implant as effectively as conventional training (CT).

Methods

Twenty-four novice surgeons (pre-registration level medical students) voluntarily participated in this trial. Baseline demographics, data on exposure to hip arthroplasty, and baseline performance in orientating an acetabular implant to six patient-specific values on a phantom pelvis, were collected prior to training. Participants were randomised to a training session either using a novel AR headset platform or receiving one-on-one tuition from a hip surgeon (CT). After training, they were asked to perform the six orientation tasks again. The solid-angle error in degrees between the planned and achieved orientations was measured using a head-mounted navigation system.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_3 | Pages 42 - 42
1 Apr 2018
Western L Logishetty K Morgan R Cobb J Auvinet E
Full Access

Background

Complications such as dislocations, impingement and early wear following total hip arthroplasty (THA) increase with acetabular cup implant malorientation. These errors are more common with low-volume centres or in novice hands. Currently, this skill is most commonly taught during real surgery with an expert trainer, but simulated training may offer a safer and more accessible solution. This study investigated if a novel MicronTracker® enhanced Microsoft HoloLens® augmented reality (EAR) headset was as effective as one-on-one expert surgeon (ES) training for teaching novice surgeons hip cup orientation skill.

Methods

Twenty-four medical students were randomly assigned to EAR or ES training groups. Participants used a modified sawbone/foam pelvis model for hip cup orientation simulation. A validated EAR headset measured the orientation of acetabular cup implants and displayed this in the participant”s field of view. The system calculated the difference between planned and achieved orientation as a solid-angle error.

Six different inclination and anteversion combinations, related to hypothetical patient-specific anatomy, were used as target orientations. Learning curves were measured over four sessions, each one week apart. Error in orientations of non-taught angles and during a concealed pelvic tilt were measured to assess translation of skills. A post-test questionnaire was used for qualitative analysis of procedure understanding and participant experience.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_4 | Pages 49 - 49
1 Apr 2018
Morgan R Logishetty K Western L Cobb J Auvinet E
Full Access

Background

Trust in the validity of a measurement tool is critical to its function in both clinical and educational settings. Acetabular cup malposition within total hip arthroplasty (THA) can lead to increased dislocation rates, impingement and increased wear as a result of edge loading. We have developed a THA simulator incorporating a foam/Sawbone pelvis model with a modified Microsoft HoloLens® augmented reality (AR) headset. We aimed to measure the trueness, precision, reliability and reproducibility of this platform for translating spatial measurements of acetabular cup orientation to angular values before developing it as a training tool.

Methods

A MicronTracker® stereoscopic camera was integrated onto a HoloLens® AR system. Trueness and precision values were obtained through comparison of the AR system measurements to a gold-standard motion capture system”s (OptiTrack®) measurements for acetabular cup orientation on a benchtop trainer, in six clinically relevant pairs of anteversion and inclination angles. Four surgeons performed these six orientations, and repeated each orientation twice. Pearson”s coefficients and Bland-Altman plots were computed to assess correlation and agreement between the AR and Motion Capture systems. Intraclass correlation coefficients (ICC) were calculated to evaluate the degree of repeatability and reproducibility of the AR system by comparing repeated tasks and between surgeons, respectively.


The Bone & Joint Journal
Vol. 98-B, Issue 11 | Pages 1479 - 1488
1 Nov 2016
Kalson NS Borthwick LA Mann DA Deehan DJ Lewis P Mann C Mont MA Morgan-Jones R Oussedik S Williams FMK Toms A Argenson JN Bellemans J Bhave A Furnes O Gollwitzer H Haddad FS Hofmann S Krenn V

Aims

The aim of this consensus was to develop a definition of post-operative fibrosis of the knee.

Patients and Methods

An international panel of experts took part in a formal consensus process composed of a discussion phase and three Delphi rounds.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_16 | Pages 69 - 69
1 Dec 2015
Williams R Kotwal R Roberts-Huntley N Khan W Morgan-Jones R
Full Access

At first-stage revision surgery for infection of total knee arthroplasties, antibiotic-impregnated cement spacers are frequently implanted. Two types of cement spacers are commonly used, “static” and “articulating” cement spacers. Advocates of cement spacers state that they deliver high doses of antibiotics locally, increase patient comfort, allow mobility and provide joint stability. They also minimize contracture of collateral ligaments, thereby facilitating re-implantation of a definitive prosthesis at a later stage. The use of these cement spacers, however, are not without significant complications, including patella tendon injuries.

We describe a series of three patients who sustained patella tendon injuries in infected total knee arthroplasties following the use of a static cement spacer at first-stage knee revision.

The patella tendon injuries resulted in significant compromise to wound healing and knee stability requiring multiple surgeries. The mid-term function was poor with an Oxford score at 24 months ranging from 12–20

Based on our experience, we advise caution in the use of static cement spacer blocks. If they are to be used, we recommend that they should be keyed in the bone to prevent patella tendon injuries.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_15 | Pages 66 - 66
1 Dec 2015
Khan W Williams R Metah A Morgan-Jones R
Full Access

Honey has been used as a topical antiseptic for at least 5,000 years. SurgiHoney is a CE licensed sterile product, which has been proven to be non-toxic and effective when used topically in the treatment of chronically infected wounds. The key difference from other medical grade honey is the broad spectrum antimicrobial characteristics with activity against Gram +ve, Gram –ve and multi-resistant organisms. Its novel role against the bacterial bioburden and biofilm associated with periprosthetic infections around total knee arthroplasties (TKA's) is therefore considered.

SurgiHoney was used as an implant coating immediately prior to wound closure after implantation of salvage endoprosthesis for multiply revised, infected TKA's undergoing staged reconstruction.

We report a consecutive series of multi-revised, infected revision TKA's where SurgiHoney was used as an active antimicrobial coating. We discuss its intra-operative application and early clinical outcomes.

The use of Surgihoney as a novel anti-microbial is established in the management of complex wound infections. This is the first reported use of SurgiHoney as a deep, implant coating in the salvage of prosthetic joint infection.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_16 | Pages 64 - 64
1 Dec 2015
Williams R Khan W Huntley N Morgan-Jones R
Full Access

Joint degeneration may make a total knee arthroplasty (TKA) a requirement for pain relief and function. However, the presence of ipsilateral limb osteomyelitis (OM) makes surgical management extremely challenging.

We report the experience of a high volume revision knee surgeon managing ipsilateral limb multi resistant OM and the outcome of subsequent TKA.

Four consecutive patients were identified who had either ipsilateral femoral or tibial chronic osteomyelitis treated prior to undergoing TKA. Surgery to eradicate the osteomyelitis involved a Lautenbach compartmental debridement, and where necessary, healing by secondary intention. The decision to proceed to a TKA was based on history, clinical examination and radiological findings of advanced osteoarthritic change.

The patients had a mean age of 50 years. They had a background of multi-organism OM and underwent single-stage TKAs at an average of 63 months following eradication of the underlying OM.

Three patients did well but had complications associated with poor skin and soft tissues, and abnormal bone anatomy. One patient developed an infection and following a re-revision had an arthrodesis.

The results for the four cases are summarised in Table 1.

We have highlighted that patients with ipsilateral limb multi resistant OM are a difficult cohort to manage.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_15 | Pages 51 - 51
1 Dec 2015
Williams R Khan W Williams H Abbas A Mehta A Ayre W Morgan-Jones R
Full Access

A common step to revision surgery for infected total knee replacement (TKR) is a thorough debridement. Whilst surgical and mechanical debridement are established as the gold standard, we investigate a novel adjuvant chemical debridement using an Acetic Acid (AA) soak that seeks to create a hostile environment for organisms, further degradation of biofilm and death of the bacteria.

We report the first orthopaedic in vivo series using AA soak as an intra-operative chemical debridement agent for treating infected TKR's. We also investigate the in vitro efficacy of AA against bacteria isolated from infected TKR's.

A prospective single surgeon consecutive series of patients with infected TKR were treated according to a standard debridement protocol. Patients in the series received sequential debridement of surgical, mechanical and finally chemical debridement with a 10 minute 3% AA soak.

In parallel, we isolated, cultured and identified bacteria from infected TKR's and assessed the in vitro efficacy of AA. Susceptibility testing was performed with AA solutions of different concentrations as well as with a control of a gentamicin sulphate disc. The effect of AA on the pH of tryptone soya was also monitored in an attempt to understand its potential mechanism of action.

Physiological responses during the AA soak were unremarkable. Intraoperatively, there were no tachycardic or arrythmic responses, any increase in respiratory rate or changes in blood pressure. This was also the case when the tourniquet was released. In addition, during the post-operative period no increase in analgesic requirements or wound complications was noted. Wound and soft tissue healing was excellent and there have not been any early recurrent infections at mean of 18 months follow up.

In vitro, zones of inhibition were formed on less than 40% of the organisms, demonstrating that AA was not directly bactericidal against the majority of the clinical isolates. However, when cultured in a bacterial suspension, AA completely inhibited the growth of the isolates at concentrations as low as 0.19%v/v.

This study has shown that the use of 3% AA soak, as part of a debridement protocol, is safe. Whilst the exact mechanism of action of acetic acid is yet to be determined, we have demonstrated that concentrations as low as 0.19%v/v in solution in vitro is sufficient to completely inhibit bacterial growth from infected TKR's.


The Bone & Joint Journal
Vol. 97-B, Issue 2 | Pages 147 - 149
1 Feb 2015
Morgan-Jones R Oussedik SIS Graichen H Haddad FS

Revision knee arthroplasty presents a number of challenges, not least of which is obtaining solid primary fixation of implants into host bone. Three anatomical zones exist within both femur and tibia which can be used to support revision implants. These consist of the joint surface or epiphysis, the metaphysis and the diaphysis. The methods by which fixation in each zone can be obtained are discussed. The authors suggest that solid fixation should be obtained in at least two of the three zones and emphasise the importance of pre-operative planning and implant selection.

Cite this article: Bone Joint J 2015;97-B:147–9.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 224 - 224
1 Jul 2014
Emohare O Christensen D Morgan R
Full Access

Summary Statement

Pedicle screws provide robust fixation and rigid immobilization. There has been no attempt to correlate the anatomic dimensions of thoracic and lumbar pedicles with the accuracy of navigated insertion. This study demonstrates that comparable accuracy using this technique.

Introduction

Pedicle screws provide robust mechanical fixation, which makes their use attractive; their use enables fixation of the three spinal columns. There remains concern about the potential both for misplacement; various investigators have studied the accuracy of pedicle screw insertions, comparing different techniques. What is not clear, however, is whether there is any relation between the variables of pedicles’ anatomic dimensions, screw dimensions and accuracy. This study aims to elucidate the relationship between these variables.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 13 - 13
1 Jul 2014
Emohare O Cagan A Dittmer A Morgan R Switzer J Polly D
Full Access

Summary Statement

Using abdominal CT scans to evaluate bone mineral density following acute fractures of the thoracic and lumbar spine demonstrates significant levels of osteoporosis in older patients; this approach may help save on time and resources, and reduce unnecessary radiation exposure.

Introduction

While a reduction in bone mineral density (BMD) is associated with aging, relatively few patients have formal dual-energy X-ray absorptiometry (DXA) to quantify the magnitude of bone loss, as they age. This loss of bone may predispose to fractures. Recent data, which correlates mean Hounsfield units (HU) in an area of the L1 vertebra with BMD, now makes it possible to screen for osteoporosis using incidental abdominal Computed Tomography (CT) scans to measure bone density. This innovation has the potential to reduce both cost and radiation exposure, and also make it easier to identify patients who may be at risk. The aims of this study were to evaluate the utility of this approach in patients with acute thoracic and lumbar spine fractures and to evaluate the impact of aging on BMD, using CT screening.


The Bone & Joint Journal
Vol. 95-B, Issue 12 | Pages 1640 - 1644
1 Dec 2013
Agarwal S Azam A Morgan-Jones R

Bone loss in the proximal tibia and distal femur is frequently encountered in revision knee replacement surgery. The various options for dealing with this depend on the extent of any bone loss. We present our results with the use of cementless metaphyseal metal sleeves in 103 patients (104 knees) with a mean follow-up of 43 months (30 to 65). At final follow-up, sleeves in 102 knees had good osseointegration. Two tibial sleeves were revised for loosening, possibly due to infection.

The average pre-operative Oxford Knee Score was 23 (11 to 36) and this improved to 32 (15 to 46) post-operatively. These early results encourage us to continue with the technique and monitor the outcomes in the long term.

Cite this article: Bone Joint J 2013;95-B:1640–4.


The Bone & Joint Journal
Vol. 95-B, Issue 11 | Pages 1441 - 1442
1 Nov 2013
Morgan-Jones R Haddad FS


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 86 - 86
1 Sep 2012
Azam A Agarwal S Morgan-Jones R
Full Access

Introduction

This study was undertaken to evaluate the early results of a new implant system - the metaphyseal sleeve - in revision total knee replacement. The femoral and tibial metaphyseal sleeves are a modular option designed to deal with metaphyseal bone loss and achieve cementless fixation over a relatively wide area in the metaphysis.

Methods

Over three years, femoral and/or tibial metaphyseal sleeves were implanted in 104 knees in 103 patients (54 male and 49 female). The clinical notes and radiographs of these patients were reviewed retrospectively. Thirty one patients had revision for infection, 42 for aseptic loosening, and 31 for instability, pain or stiffness. Eighty nine knees were revised as a single stage and 15 were done as two stage procedure. Minimum follow up is 12 months (average 18.5 months).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 51 - 51
1 Sep 2012
Edwards G Hall A Morgan-Jones R
Full Access

We describe the results for the management of chronic osteomyelitis in long bones using a new single stage procedure, the Cardiff technique. Fourteen consecutive patients were treated prospectively. The patients had a mean age of 52; all patients had a mean stay in hospital of 5 days with outpatient dressings. All patients had tibial fractures, 2 were infected non unions. The origin of infection was traumatic in 13 cases and haematogenous in 1 case. This one stage procedure or The Cardiff technique, uses techniques described by both Papineau's 3 stage method and Lautenbach's procedure. It involves removal of all avascular and infected tissue via marginal debridement, opening of the medullary cavity proximally and distally, compartmental debridement and copious saline irrigation. The wound is then packed with Jelonet and kaltostat and fresh dressings applied weekly. The wound is left to heal via secondary intention. There is no routine use of antibiotics. Antibiotics were only used when required, i.e. Clinical evidence of cellulitis or infection. 11 patients healed with no further surgery, no skin grafting, no bone grafting and no flap coverage. Mean time to healing was 5 months; both non unions united giving results similar to other accepted techniques. There were 3 residual infections, 2 due to inadequate debridement which required a single further compartmental debridement (Lautenbach method), 1 had an avascular bone edge requiring further local debridement. We feel this procedure confers the following advantages; minimal surgical insult, early discharge, out patient management, good outcomes and most importantly, high patient satisfaction. It also serves as a reminder that simple wounds do well with simple solutions.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIX | Pages 56 - 56
1 Jul 2012
Azam A Agarwal S Morgan-Jones R
Full Access

Purpose of the study

This study was undertaken to evaluate the early results of a new implant system - the metaphyseal sleeve - in revision total knee replacement. The femoral and tibial metaphyseal sleeves are a modular option designed to deal with metaphyseal bone loss and achieve cementless fixation over a relatively wide area in the metaphysis.

Methods

Over three years, femoral and/or tibial metaphyseal sleeves were implanted in 104 knees in 103 patients (54 male and 49 female). The clinical notes and radiographs of these patients were reviewed retrospectively. Thirty one patients had revision for infection, 42 for aseptic loosening, and 31 for instability, pain or stiffness. Eighty nine knees were revised as a single stage and 15 were done as two stage procedure. Minimum follow up is 12 months (average 18.5 months).


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 7 | Pages 875 - 881
1 Jul 2012
Vanhegan IS Morgan-Jones R Barrett DS Haddad FS

This review summarises the opinions and conclusions reached from a symposium on infected total knee replacement (TKR) held at the British Association of Surgery of the Knee (BASK) annual meeting in 2011. The National Joint Registry for England and Wales reported 5082 revision TKRs in 2010, of which 1157 (23%) were caused by infection. The diagnosis of infection beyond the acute post-operative stage relies on the identification of the causative organism by aspiration and analysis of material obtained at arthroscopy. Ideal treatment then involves a two-stage surgical procedure with extensive debridement and washout, followed by antibiotics. An articulating or non-articulating drug-eluting cement spacer is used prior to implantation of the revision prosthesis, guided by the serum level of inflammatory markers. The use of a single-stage revision is gaining popularity and we would advocate its use in certain patients where the causative organism is known, no sinuses are present, the patient is not immunocompromised, and there is no radiological evidence of component loosening or osteitis.

It is our opinion that single-stage revision produces high-quality reproducible results and will soon achieve the same widespread acceptance as it does in infected hip arthroplasty.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_II | Pages 88 - 88
1 Feb 2012
Shyamsundar S Morgan R Birch M Campbell P McCaskie A Fenwick S
Full Access

Clinical proteomics is an exciting new sub-discipline of proteomics that involves the application of proteomic technologies at the bedside to identify new biomarkers, associated with specific diseases. In this study to compare serum protein profiles between identical age-matched groups of fracture and non-fracture controls, we looked at the initial proteomic profile of 10 patients who had fractures and compared them to age-matched controls to see if there was any specific difference indicative of fracture.

Materials and Methods

10 patients with single fractures of the long bones, wrist or ankle gave a blood sample upon presentation at the fracture clinic. 10 healthy, age-matched, non-fracture volunteers also donated blood. Plasma was isolated and the albumin and IgG fractions removed before loading equal amounts of each sample onto 2 dimensional polyacrylamide gels for analysis by isoelectric point in the first dimension and molecular mass in the second dimension. Protein profiles between fracture patients and non-fracture controls were contrasted using Phoretix 2D analysis software.

Data analysis differentiated between the average gel of the patient group and the average gel of the control group. More than 300 protein spots were observed in both the control and patient group. Seven protein spots were identified which showed a statistically significant (p<0.05) difference between the control and patient samples. Of these, three spots (X, Y, Z) were clear, distinct and present in at least 80% of these gels. All the three spots were up regulated in the patient group as opposed to the control group. These proteins are currently being investigated further by MALDI-TOF TOF for specific protein identification.

Discussion

Proteomic analysis is already a powerful tool in the identification of disease markers. We aim to show here that there are differences seen in blood plasma profiles in fracture patients compared to non-fracture healthy controls. The differences seen may help us to understand the fracture repair process better.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_I | Pages 41 - 41
1 Jan 2011
Caesar B Morgan-Jones R Warren R Wade R Roberts P Richardson J
Full Access

Thirty-five patients were followed prospectively from their referral to the Problem Fracture Service with chronic osteomyelitis of diaphyseal bone between November 1994 and June 1999.

The patients were treated using a closed double-lumen suction irrigation system following reaming and arthroscopic debridement of the intramedullary canal; this is a modified system based on the work of Charles Lautenbach. Results of these procedures were regularly followed up in clinic, and between June and July 2007 the whole cohort was reviewed via postal questionnaire, telephone and case note review.

At a mean follow up of 101 months, 26 were living with no evidence of recurrence, 4 had died of unrelated causes with no evidence of recurrent infection. Four patients had persisting problems with sinus discharge requiring intermittent antibiotic therapy and 1 patient had his limb amputated for recurrent metaplastic change.

These results gave this cohort an 86% clearance of infection, with recurrence in 12%, which is comparable to the Papineau and Belfast techniques with significantly less surgical insult to the patient.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_III | Pages 409 - 410
1 Jul 2010
Kotwal RS Prasad N Morgan-Jones R
Full Access

Purpose of the study: The purpose of this study is to present our initial experience of single stage revision surgery for infected total knee arthroplasty (TKA).

Methods and results: 12 patients underwent single stage revision for infected TKA. The average patient age was 72.5 years and M: F was 2:1. 5 of the 12 patients had frank infection with presence of discharging sinuses pre-operatively. The procedure involved explantation, debridement, subtotal synovectomy, use of high pressure carbon dioxide (Carbojet) and re-implantation using revision prosthesis and antibiotic laden cement. Utmost care was taken to restore the balance and stability of the revised knee. All the patients were given appropriate intravenous and oral antibiotics in the peri-operative period. Oxford knee scores (OKS) were obtained pre-operatively and at the latest follow-up. Patient satisfaction was also assessed.

At the latest follow-up, none of the patients had recurrence of the infection nor did they need any further surgical procedure. There was no radiographic evidence of loosening of the prosthesis. The OKS had improved from a mean of 17 pre-operative to 41 at the latest follow-up. All the patients were extremely satisfied with the outcome.

Conclusion: Knee function and patient satisfaction improved significantly after single stage revision for infected TKA. None of the patients needed further surgery in the short term. Early results are very encouraging and this change in practice may save on costs and patient morbidity associated with the second stage.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_III | Pages 419 - 419
1 Jul 2010
Kotwal RS Fairclough J Morgan-Jones R
Full Access

Purpose of the study: We report an unusual complication of patella tendon rupture that occurred secondary to the use of static cement spacer blocks in a series of three patients undergoing staged revision total knee arthroplasty (TKA) for infection.

Methods and results: 3 male patients developed patella tendon injury secondary to anterior subluxation of static cement spacer blocks used at the first of a two-stage revision procedure for infected TKA. Average patient age was 70 years. The interval between the 1st and the 2nd stages varied between 3.5 to 24 months. At the second stage, it was observed that the patella tendon was completely severed and irreparable in one case, whereas it was partially injured and repairable in the other two cases. In the case with irreparable tendon injury, stable joint reconstruction could not be achieved at the second stage and ultimately resulted in knee arthrodesis. In the other two cases, 2nd stage revision was performed using hinged revision knee components and the tendon injury was repaired and protected with a circlage wire. None of the patients were satisfied with their outcome at the final review.

Conclusion: This is the first report in the literature reporting the complication of patella tendon rupture secondary to the use of static cement spacer blocks in staged revision knee arthroplasty. The injury can either be repairable or irreparable. The functional outcome and satisfaction is not good after the salvage procedures. Therefore, we recommend that these spacer blocks should not be used in revision knee arthroplasty.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 78 - 78
1 Mar 2009
Gudena R Mehta J Morgan-Jones R
Full Access

Introduction: Sequential staged distraction with fixed rate and rhythm, alternative compression and distraction is well described in the literature to treat non-unions. However we looked the union in established non-unions of tibia using one stage distraction without further manipulation at the fracture site maintaining the stability.

Materials and Methods: 12 patients with established tibial non-unions were referred during the period of 2001–2005. 2 cases were infected non unions. All patients were symptomatic and exhibited deformity at the non-union site. Ten males, two females were in the study group with a mean age of 39.2 years. The location of non-union was distal 1/3 of tibia in 8 cases and 2 cases of proximal and middle 1/3. External fixation was used to acutely distract the fracture (one stage) and tension the soft tissues to attain fracture stability. Infection at the fracture site required further operative debridement. Regular followup with radiographs to assess the union.

Results: Osseous union was achieved in all the cases at an average time period of 17.2 weeks. There was no recurrence of osteomyelitis in the infected cases following secondary debridement. All the patients were pain free and fully mobile without aid at review.

Conclusion: We concluded that acute distraction osteogenesis produces fracture union in selected established cases of non union. This method can be used to obtain impressive gains in the lengths of the long bones. Bone is uniformly produced regardless of the location of the non union. This is more patient compliant, effective and relatively easy to perform.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 190 - 190
1 Mar 2008
Wood J Cates M Mackel A Morgan R Poggie R
Full Access

This paper reports the prospective 2 to 4 year clinical results of a porous tantalum monoblock tibia used in primary TKR, with comparison to a cemented modular tibial implant of the same articulating design.

The subject tibial implant is relatively flexible design comprised of a porous tantalum base plate and direct compression molded polyethylene, with initial fixation achieved by press-fitting two porous tantalum posts. The porous tantalum implant was used without bone cement in 72 knees and with cement in 29 cases. The comparative tibial component was a cemented modular design with the same articulating surface. Clinical and radiographic data were collected prospectively, and consecutively, for 165 primary TKR cases implanted from 2000 – 2003

James Wood, Maurice Cates, Audley Mackel, Randall Morgan, Robert Poggie

The early clinical and radiographic results for the porous tantalum monoblock tibia (cemented and cementless) and the modular cemented implant were statistically the same. The preliminary evidence suggests that cementless application of this design is an attractive alternative for younger, more active patients.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_III | Pages 447 - 447
1 Oct 2006
Pinto M Morgan R Lonstein J Lam G Wroblewski J
Full Access

Introduction The frequency of spine surgery in the elderly continues to increase in parallel with the overall aging of the population. The main goal of this study was to determine if age is a risk factor for major complications in spine surgery. In addition, other co-morbidities and the relationship with age and potential for major complications were explored.

Methods All adult patients undergoing spine surgery at our center over a four-year period were included in this study, for a total of 1937 patients (605 age 18 – 39; 1001 age 40–64, 331 age 65 and over). One independent observer abstracted baseline medical histories and co-morbidities as well as post-operative complications. Major risk factors explored included history of cardiac, cancer, smoking, diabetes, substance abuse, obesity, respiratory problems, previous infections and hypercholesterolemia. Details of surgical procedure, including type of surgery, duration of surgery and blood loss were also captured. Major complications were defined as death, CVA, embolism, pneumonia and deep wound infections.

Patients ranged in age from 18 years to 91 (average age 48 years) and 41% were males. Thirty percent of the population was deformity patients, 49% degenerative patients and the remaining 21% had various other spine problems. Thirty-five percent of the patients underwent a combined anterior posterior procedure, 13% anterior alone and 34% posterior alone.

Statistical analysis included descriptive summary, vicariate correlation to assess individual risk factors (university analysis) and multivariate regression.

Results The overall major complication rate was 2.1% (40 patients). There were no intra- or post-operative deaths. Major complications included 7 CVA (0.4%), 2 embolisms (0.1%), 3 deep wound infections (0.2%) and 28 pneumonia (1.4). For patients age 65 or older,

Overall, 61% of the patients had at least one of the major risk factors. The number of major risk factors increased with increased age. The percent of patients with any given risk factor also increased with age.

When no other factors were taken into account (such as co-morbidities), there was an increased occurrence of a major complication (any one), pneumonia and infection with increased age at time of surgery. In order to differentiate the effect due to age and due to co-morbidities (which increased with age), multivariate regression was utilized. For the occurrence of any major complication, the presence of respiratory problems and previous infection were both more influential than age. Furthermore, when the effects of these two risk factors were controlled for, there no longer was an effect due to age.

Discussion Older patients did not have an increased rate of major complications when compared to younger patients with similar respirator and infection history profiles.


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_I | Pages 30 - 30
1 Jan 2003
Morgan-Jones R Joneleit M Solis G Cross MJ
Full Access

To document the incidence of intra-articular pathology resulting from delayed Anterior Cruciate Ligament (ACL) reconstruction

A prospective assessment of meniscal and chondral damage found at the time of primary ACL reconstruction, and the relationship of incidence of intra-articular pathology to time since original ACL injury.

We reviewed 1960 patients who had undergone a primary ACL reconstruction. There were 1443 Males and 517 females, with an average age of 28.3 years. The average age at injury was 25.4 years.

1136 patients (58%) had secondary intra-articular pathology, 621 (54.7%) had a medial meniscal tear, 594 (52.4%) had a lateral meniscal tear and 381 (33.5%) had chondral damage. The average time from injury to reconstruction was 2.9 years (34.8 months) Those with secondary intraarticular pathology presented for reconstruction later, average 3.9 years (46.8 months), compared to those without secondary pathology, average 1.5 years (18 months).

The incidence of secondary intra-articular pathology increased with delay between original ACL injury and reconstruction. 41% of those waiting 12 months; 60% of those waiting 3 years; 79% of those waiting 5 years and 88% of those waiting 10 years had secondary intra-articular pathology.

This study confirms the relationship between an unstable ACL deficient knee and the incidence of secondary intra-articular pathology. Furthermore, our study reveals the increasing incidence of meniscal and chondral pathology the greater the delay from injury to ACL reconstruction. To prevent unnecessary secondary intra-articular pathology we recommend ACL reconstruction is performed with minimal delay.


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_III | Pages 269 - 269
1 Nov 2002
Cross M Roger G Morgan-Jones R Machan S Parish E
Full Access

Introduction: The Motus (Osteo) total knee replacement design is an uncemented, stemless, hydroxyapatite-coated prosthesis designed as a low profile resurfacing implant.

Aim: To review the results after five to eight years of the use of this prosthesis by one surgeon and to discuss the perceived advantages of its design.

Methods: Between 1992 and 1996 the Motus (Osteo) prosthesis was used in 606 primary total knee replacements in 409 patients. The evaluation was undertaken using a clinical knee score based on the Knee Society Score and the Hospital for Special Surgery (HSS) score, which produces a maximum score of 200/200.

Results: The mean age was 69 years (range: 31 to 88 years) with 53% of the patients being female. Osteoarthritis was the underlying pathology in the majority of the cases. The minimum time to follow up was 60 months (mean: 79, range: 60 to 104 months). The mean pre-operative knee score was 98/200 with a range of movement from six degrees to 122 degrees. After five years, the mean knee score was 180/200 with a range of movement from one degree to 113 degrees. To date only two patients have required a revision procedure, both for deep infection. Twenty-six patients have died and six have been lost to follow-up as they are overseas.

Conclusion: At a minimum five-year review, the Motus (Osteo) total knee replacement prosthesis produced excellent functional and clinical results with a low rate of complications.