Advertisement for orthosearch.org.uk
Results 1 - 50 of 698
Results per page:
The Bone & Joint Journal
Vol. 97-B, Issue 6 | Pages 723 - 728
1 Jun 2015
Hamilton DF Howie CR Burnett R Simpson AHRW Patton JT

Worldwide rates of primary and revision total knee arthroplasty (TKA) are rising due to increased longevity of the population and the burden of osteoarthritis. Revision TKA is a technically demanding procedure generating outcomes which are reported to be inferior to those of primary knee arthroplasty, and with a higher risk of complication. Overall, the rate of revision after primary arthroplasty is low, but the number of patients currently living with a TKA suggests a large potential revision healthcare burden. Many patients are now outliving their prosthesis, and consideration must be given to how we are to provide the necessary capacity to meet the rising demand for revision surgery and how to maximise patient outcomes. The purpose of this review was to examine the epidemiology of, and risk factors for, revision knee arthroplasty, and to discuss factors that may enhance patient outcomes. Cite this article: Bone Joint J 2015; 97-B:723–8


The Bone & Joint Journal
Vol. 104-B, Issue 10 | Pages 1126 - 1131
1 Oct 2022
Hannon CP Kruckeberg BM Pagnano MW Berry DJ Hanssen AD Abdel MP

Aims. We have previously reported the mid-term outcomes of revision total knee arthroplasty (TKA) for flexion instability. At a mean of four years, there were no re-revisions for instability. The aim of this study was to report the implant survivorship and clinical and radiological outcomes of the same cohort of of patients at a mean follow-up of ten years. Methods. The original publication included 60 revision TKAs in 60 patients which were undertaken between 2000 and 2010. The mean age of the patients at the time of revision TKA was 65 years, and 33 (55%) were female. Since that time, 21 patients died, leaving 39 patients (65%) available for analysis. The cumulative incidence of any re-revision with death as a competing risk was calculated. Knee Society Scores (KSSs) were also recorded, and updated radiographs were reviewed. Results. The cumulative incidence of any re-revision was 13% at a mean of ten years. At the most recent-follow-up, eight TKAs had been re-revised: three for recurrent flexion instability (two fully revised to varus-valgus constrained implants (VVCs), and one posterior-stabilized (PS) implant converted to VVC, one for global instability (PS to VVC), two for aseptic loosening of the femoral component, and two for periprosthetic joint infection). The ten-year cumulative incidence of any re-revision for instability was 7%. The median KSS improved significantly from 45 (interquartile range (IQR) 40 to 50) preoperatively to 70 (IQR 45 to 80) at a mean follow-up of ten years (p = 0.031). Radiologically, two patients, who had not undergone revision, had evidence of loosening (one tibial and one patellar). The remaining components were well fixed. Conclusion. We found fair functional outcomes and implant survivorship at a mean of ten years after revision TKA for flexion instability with a PS implant. Recurrent instability and aseptic loosening were the most common indications for re-revision. Components with increased constraint, such as a VVC or hinged, should be used in these patients in order to reduce the risk of recurrent instability. Cite this article: Bone Joint J 2022;104-B(10):1126–1131


The Bone & Joint Journal
Vol. 103-B, Issue 6 Supple A | Pages 165 - 170
1 Jun 2021
Larson DJ Rosenberg JH Lawlor MA Garvin KL Hartman CW Lyden E Konigsberg BS

Aims. Stemmed tibial components are frequently used in revision total knee arthroplasty (TKA). The purpose of this study was to evaluate patient satisfaction, overall pain, and diaphyseal tibial pain in patients who underwent revision TKA with cemented or uncemented stemmed tibial components. Methods. This is a retrospective cohort study involving 110 patients with revision TKA with cemented versus uncemented stemmed tibial components. Patients who underwent revision TKA with stemmed tibial components over a 15-year period at a single institution with at least two-year follow-up were assessed. Pain was evaluated through postal surveys. There were 63 patients with cemented tibial stems and 47 with uncemented stems. Radiographs and Knee Society Scores were used to evaluate for objective findings associated with pain or patient dissatisfaction. Postal surveys were analyzed using Fisher’s exact test and the independent-samples t-test. Logistic regression was used to adjust for age, sex, and preoperative bone loss. Results. No statistically significant differences in stem length, operative side, or indications for revision were found between the two cohorts. Tibial pain at the end of the stem was present in 25.3% (16/63) of cemented stems and 25.5% (12/47) of uncemented stems (p = 1.000); 74.6% (47/63) of cemented patients and 78.7% (37/47) of uncemented patients were satisfied following revision TKA (p = 0.657). Conclusion. There were no differences in patient satisfaction, overall pain, and diaphyseal tibial pain in cemented and uncemented stemmed tibial components in revision TKA. Patient factors, rather than implant selection and surgical technique, likely play a large role in the presence of postoperative pain. Stemmed tibial components have been shown to be a possible source of pain in revision TKA. There is no difference in patient satisfaction or postoperative pain with cemented or uncemented stemmed tibial components in revision TKA. Cite this article: Bone Joint J 2021;103-B(6 Supple A):165–170


Bone & Joint Open
Vol. 1, Issue 3 | Pages 29 - 34
13 Mar 2020
Stirling P Middleton SD Brenkel IJ Walmsley PJ

Introduction. The primary aim of this study was to describe a baseline comparison of early knee-specific functional outcomes following revision total knee arthroplasty (TKA) using metaphyseal sleeves with a matched cohort of patients undergoing primary TKA. The secondary aim was to compare incidence of complications and length of stay (LOS) between the two groups. Methods. Patients undergoing revision TKA for all diagnoses between 2009 and 2016 had patient-reported outcome measures (PROMs) collected prospectively. PROMs consisted of the American Knee Society Score (AKSS) and Short-Form 12 (SF-12). The study cohort was identified retrospectively and demographics were collected. The cohort was matched to a control group of patients undergoing primary TKA. Results. Overall, 72 patients underwent revision TKA and were matched with 72 primary TKAs with a mean follow-up of 57 months (standard deviation (SD) 20 months). The only significant difference in postoperative PROMs was a worse AKSS pain score in the revision group (36 vs 44, p = 0.002); however, these patients still produced an improvement in the pain score. There was no significant difference in improvement of AKSS or SF-12 between the two groups. LOS (9.3 days vs 4.6 days) and operation time (1 hour 56 minutes vs 1 hour 7 minutes) were significantly higher in the revision group (p < 0.001). Patients undergoing revision were significantly more likely to require intraoperative lateral release and postoperative urinary catheterisation (p < 0.001). Conclusion. This matched-cohort study provides results of revision TKA using modern techniques and implants and outlines what results patients can expect to achieve using primary TKA as a control. This should be useful to clinicians counselling patients for revision TKA


The Bone & Joint Journal
Vol. 103-B, Issue 6 | Pages 1103 - 1110
1 Jun 2021
Tetreault MW Hines JT Berry DJ Pagnano MW Trousdale RT Abdel MP

Aims. This study aimed to determine outcomes of isolated tibial insert exchange (ITIE) during revision total knee arthroplasty (TKA). Methods. From 1985 to 2016, 270 ITIEs were performed at one institution for instability (55%, n = 148), polyethylene wear (39%, n = 105), insert fracture/dissociation (5%, n = 14), or stiffness (1%, n = 3). Patients with component loosening, implant malposition, infection, and extensor mechanism problems were excluded. Results. Survivorship free of any re-revision was 68% at ten years. For the indication of insert wear, survivorship free of any re-revision at ten years was 74%. Re-revisions were more frequent for index diagnoses other than wear (hazard ratio (HR) 1.9; p = 0.013), with ten-year survivorships of 69% for instability and 37% for insert fracture/dissociation. Following ITIE for wear, the most common reason for re-revision was aseptic loosening (33%, n = 7). For other indications, the most common reason for re-revision was recurrence of the original diagnosis. Mean Knee Society Scores improved from 54 (0 to 94) preoperatively to 77 (38 to 94) at ten years. Conclusion. After ITIE, the risk and reasons for re-revision correlated with preoperative indications. The best results were for polyethylene wear. For other diagnoses, the re-revision rate was higher and the failure mode was most commonly recurrence of the original indication for the revision TKA. Cite this article: Bone Joint J 2021;103-B(6):1103–1110


The Bone & Joint Journal
Vol. 105-B, Issue 10 | Pages 1078 - 1085
1 Oct 2023
Cance N Batailler C Shatrov J Canetti R Servien E Lustig S

Aims. Tibial tubercle osteotomy (TTO) facilitates surgical exposure and protects the extensor mechanism during revision total knee arthroplasty (rTKA). The purpose of this study was to determine the rates of bony union, complications, and reoperations following TTO during rTKA, to assess the functional outcomes of rTKA with TTO at two years’ minimum follow-up, and to identify the risk factors of failure. Methods. Between January 2010 and September 2020, 695 rTKAs were performed and data were entered into a prospective database. Inclusion criteria were rTKAs with concomitant TTO, without extensor mechanism allograft, and a minimum of two years’ follow-up. A total of 135 rTKAs were included, with a mean age of 65 years (SD 9.0) and a mean BMI of 29.8 kg/m. 2. (SD 5.7). The most frequent indications for revision were infection (50%; 68/135), aseptic loosening (25%; 34/135), and stiffness (13%; 18/135). Patients had standardized follow-up at six weeks, three months, six months, and annually thereafter. Complications and revisions were evaluated at the last follow-up. Functional outcomes were assessed using the Knee Society Score (KSS) and range of motion. Results. The mean follow-up was 51 months (SD 26; 24 to 121). Bony union was confirmed in 95% of patients (128/135) at a mean of 3.4 months (SD 2.7). The complication rate was 15% (20/135), consisting of nine tibial tubercle fracture displacements (6.7%), seven nonunions (5%), two delayed unions, one tibial fracture, and one wound dehiscence. Seven patients (5%) required eight revision procedures (6%): three bone grafts, three osteosyntheses, one extensor mechanism allograft, and one wound revision. The functional scores and flexion were significantly improved after surgery: mean KSS knee, 48.8 (SD 17) vs 79.6 (SD 20; p < 0.001); mean KSS function, 37.6 (SD 21) vs 70.2 (SD 30; p < 0.001); mean flexion, 81.5° (SD 33°) vs 93° (SD 29°; p = 0.004). Overall, 98% of patients (n = 132) had no extension deficit. The use of hinge implants was a significant risk factor for tibial tubercle fracture (p = 0.011). Conclusion. TTO during rTKA was an efficient procedure to improve knee exposure with a high union rate, but had significant specific complications. Functional outcomes were improved at mid term. Cite this article: Bone Joint J 2023;105-B(10):1078–1085


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 46 - 46
1 Dec 2022
Sheridan G Garbuz D Masri B
Full Access

The demand for revision total knee arthroplasty (TKA) has grown significantly in recent years. The two major fixation methods for stems in revision TKA include cemented and ‘hybrid’ fixation. We explore the optimal fixation method using data from recent, well-designed comparative studies. We performed a systematic review of comparative studies published within the last 10 years with a minimum follow-up of 24 months. To allow for missing data, a random-effects meta-analysis of all available cases was performed. The odds ratio (OR) for the relevant outcome was calculated with 95% confidence intervals. The effects of small studies were analyzed using a funnel plot, and asymmetry was assessed using Egger's test. The primary outcome measure was all-cause failure. Secondary outcome measures included all-cause revision, aseptic revision and radiographic failure. There was a significantly lower failure rate for hybrid stems when compared to cemented stems (p = 0.006) (OR 0.61, 95% CI 0.42-0.87). Heterogeneity was 4.3% and insignificant (p = 0.39). There was a trend toward superior hybrid performance for all other outcome measures including all-cause re-revision, aseptic re-revision and radiographic failure. Recent evidence suggests a significantly lower failure rate for hybrid stems in revision TKA. There is also a trend favoring the use of hybrid stems for all outcome variables assessed in this study. This is the first time a significant difference in outcome has been demonstrated through systematic review of these two modes of stem fixation. We therefore recommend the use, where possible, of hybrid stems in revision TKA


The Bone & Joint Journal
Vol. 106-B, Issue 5 | Pages 468 - 474
1 May 2024
d'Amato M Flevas DA Salari P Bornes TD Brenneis M Boettner F Sculco PK Baldini A

Aims. Obtaining solid implant fixation is crucial in revision total knee arthroplasty (rTKA) to avoid aseptic loosening, a major reason for re-revision. This study aims to validate a novel grading system that quantifies implant fixation across three anatomical zones (epiphysis, metaphysis, diaphysis). Methods. Based on pre-, intra-, and postoperative assessments, the novel grading system allocates a quantitative score (0, 0.5, or 1 point) for the quality of fixation achieved in each anatomical zone. The criteria used by the algorithm to assign the score include the bone quality, the size of the bone defect, and the type of fixation used. A consecutive cohort of 245 patients undergoing rTKA from 2012 to 2018 were evaluated using the current novel scoring system and followed prospectively. In addition, 100 first-time revision cases were assessed radiologically from the original cohort and graded by three observers to evaluate the intra- and inter-rater reliability of the novel radiological grading system. Results. At a mean follow-up of 90 months (64 to 130), only two out of 245 cases failed due to aseptic loosening. Intraoperative grading yielded mean scores of 1.87 (95% confidence interval (CI) 1.82 to 1.92) for the femur and 1.96 (95% CI 1.92 to 2.0) for the tibia. Only 3.7% of femoral and 1.7% of tibial reconstructions fell below the 1.5-point threshold, which included the two cases of aseptic loosening. Interobserver reliability for postoperative radiological grading was 0.97 for the femur and 0.85 for the tibia. Conclusion. A minimum score of 1.5 points for each skeletal segment appears to be a reasonable cut-off to define sufficient fixation in rTKA. There were no revisions for aseptic loosening at mid-term follow-up when this fixation threshold was achieved or exceeded. When assessing first-time revisions, this novel grading system has shown excellent intra- and interobserver reliability. Cite this article: Bone Joint J 2024;106-B(5):468–474


Bone & Joint Open
Vol. 4, Issue 6 | Pages 399 - 407
1 Jun 2023
Yeramosu T Ahmad W Satpathy J Farrar JM Golladay GJ Patel NK

Aims. To identify variables independently associated with same-day discharge (SDD) of patients following revision total knee arthroplasty (rTKA) and to develop machine learning algorithms to predict suitable candidates for outpatient rTKA. Methods. Data were obtained from the American College of Surgeons National Quality Improvement Programme (ACS-NSQIP) database from the years 2018 to 2020. Patients with elective, unilateral rTKA procedures and a total hospital length of stay between zero and four days were included. Demographic, preoperative, and intraoperative variables were analyzed. A multivariable logistic regression (MLR) model and various machine learning techniques were compared using area under the curve (AUC), calibration, and decision curve analysis. Important and significant variables were identified from the models. Results. Of the 5,600 patients included in this study, 342 (6.1%) underwent SDD. The random forest (RF) model performed the best overall, with an internally validated AUC of 0.810. The ten crucial factors favoring SDD in the RF model include operating time, anaesthesia type, age, BMI, American Society of Anesthesiologists grade, race, history of diabetes, rTKA type, sex, and smoking status. Eight of these variables were also found to be significant in the MLR model. Conclusion. The RF model displayed excellent accuracy and identified clinically important variables for determining candidates for SDD following rTKA. Machine learning techniques such as RF will allow clinicians to accurately risk-stratify their patients preoperatively, in order to optimize resources and improve patient outcomes. Cite this article: Bone Jt Open 2023;4(6):399–407


Bone & Joint Open
Vol. 2, Issue 10 | Pages 785 - 795
1 Oct 2021
Matar HE Porter PJ Porter ML

Aims. Metal allergy in knee arthroplasty patients is a controversial topic. We aimed to conduct a scoping review to clarify the management of metal allergy in primary and revision total knee arthroplasty (TKA). Methods. Studies were identified by searching electronic databases: Cochrane Central Register of Controlled Trials, Ovid MEDLINE, and Embase, from their inception to November 2020, for studies evaluating TKA patients with metal hypersensitivity/allergy. All studies reporting on diagnosing or managing metal hypersensitivity in TKA were included. Data were extracted and summarized based on study design, study population, interventions and outcomes. A practical guide is then formulated based on the available evidence. Results. We included 38 heterogeneous studies (two randomized controlled trials, six comparative studies, 19 case series, and 11 case reports). The evidence indicates that metal hypersensitivity is a rare complication with some histopathological features leading to pain and dissatisfaction with no reliable screening tests preoperatively. Hypoallergenic implants are viable alternatives for patients with self-reported/confirmed metal hypersensitivity if declared preoperatively; however, concerns remain over their long-term outcomes with ceramic implants outperforming titanium nitride-coated implants and informed consent is paramount. For patients presenting with painful TKA, metal hypersensitivity is a diagnosis of exclusion where patch skin testing, lymphocyte transformation test, and synovial biopsies are useful adjuncts before revision surgery is undertaken to hypoallergenic implants with shared decision-making and informed consent. Conclusion. Using the limited available evidence in the literature, we provide a practical approach to metal hypersensitivity in TKA patients. Future national/registry-based studies are needed to identify the scale of metal hypersensitivity, agreed diagnostic criteria, and management strategies. Cite this article: Bone Jt Open 2021;2(10):785–795


Bone & Joint Open
Vol. 5, Issue 8 | Pages 644 - 651
7 Aug 2024
Hald JT Knudsen UK Petersen MM Lindberg-Larsen M El-Galaly AB Odgaard A

Aims. The aim of this study was to perform a systematic review and bias evaluation of the current literature to create an overview of risk factors for re-revision following revision total knee arthroplasty (rTKA). Methods. A systematic search of MEDLINE and Embase was completed in accordance with the Preferred Reporting Items for Systematic reviews and Meta-Analyses (PRISMA) guidelines. The studies were required to include a population of index rTKAs. Primary or secondary outcomes had to be re-revision. The association between preoperative factors and the effect on the risk for re-revision was also required to be reported by the studies. Results. The search yielded 4,847 studies, of which 15 were included. A majority of the studies were retrospective cohorts or registry studies. In total, 26 significant risk factors for re-revision were identified. Of these, the following risk factors were consistent across multiple studies: age at the time of index revision, male sex, index revision being partial revision, and index revision due to infection. Modifiable risk factors were opioid use, BMI > 40 kg/m. 2. , and anaemia. History of one-stage revision due to infection was associated with the highest risk of re-revision. Conclusion. Overall, 26 risk factors have been associated with an increased risk of re-revision following rTKA. However, various levels of methodological bias were found in the studies. Future studies should ensure valid comparisons by including patients with identical indications and using clear definitions for accurate assessments. Cite this article: Bone Jt Open 2024;5(8):644–651


Bone & Joint Open
Vol. 4, Issue 10 | Pages 776 - 781
16 Oct 2023
Matar HE Bloch BV James PJ

Aims. The aim of this study was to evaluate medium- to long-term outcomes and complications of the Stanmore Modular Individualised Lower Extremity System (SMILES) rotating hinge implant in revision total knee arthroplasty (rTKA) at a tertiary unit. It is hypothesized that this fully cemented construct leads to satisfactory clinical outcomes. Methods. A retrospective consecutive study of all patients who underwent a rTKA using the fully cemented SMILES rotating hinge prosthesis between 2005 to 2018. Outcome measures included aseptic loosening, reoperations, revision for any cause, complications, and survivorship. Patients and implant survivorship data were identified through both prospectively collected local hospital electronic databases and linked data from the National Joint Registry/NHS Personal Demographic Service. Kaplan-Meier survival analysis was used at ten years. Results. Overall, 69 consecutive patients (69 knees) were included with a median age of 78 years (interquartile range 69 to 84), and there were 46 females (66.7%). Indications were septic revisions in 26 (37.7%), and aseptic aetiology in the remining 43 (62.3%). The mean follow-up was 9.7 years (4 to 18), and the overall complication was rate was 7.24%, all with patellofemoral complications. Failure rate with ‘any cause revision’ was 5.8%. There was one case of aseptic loosening of the femoral component. At ten years, 17/69 patients (24.63%) had died, and implant survivorship was 92.2%. Conclusion. In our experience, the SMILES rotating hinge prosthesis achieves satisfactory long-term outcomes with ten-year implant survivorship of 92.2% and a patellofemoral complication rate of 7.24%. Cite this article: Bone Jt Open 2023;4(10):776–781


The Bone & Joint Journal
Vol. 101-B, Issue 7_Supple_C | Pages 10 - 16
1 Jul 2019
Fillingham YA Darrith B Calkins TE Abdel MP Malkani AL Schwarzkopf R Padgett DE Culvern C Sershon RA Bini S Della Valle CJ

Aims. Tranexamic acid (TXA) is proven to reduce blood loss following total knee arthroplasty (TKA), but there are limited data on the impact of similar dosing regimens in revision TKA. The purpose of this multicentre randomized clinical trial was to determine the optimal regimen to maximize the blood-sparing properties of TXA in revision TKA. Patients and Methods. From six-centres, 233 revision TKAs were randomized to one of four regimens: 1 g of intravenous (IV) TXA given prior to the skin incision, a double-dose regimen of 1 g IV TXA given both prior to skin incision and at time of wound closure, a combination of 1 g IV TXA given prior to skin incision and 1 g of intraoperative topical TXA, or three doses of 1950 mg oral TXA given two hours preoperatively, six hours postoperatively, and on the morning of postoperative day one. Randomization was performed based on the type of revision procedure to ensure equivalent distribution among groups. Power analysis determined that 40 patients per group were necessary to identify a 1 g/dl difference in the reduction of haemoglobin postoperatively between groups with an alpha of 0.05 and power of 0.80. Per-protocol analysis involved regression analysis and two one-sided t-tests for equivalence. Results. In total, one patient withdrew, five did not undergo surgery, 16 were screening failures, and 25 did not receive the assigned treatment, leaving 186 patients for analysis. There was no significant difference in haemoglobin reduction among treatments (2.8 g/dl for single-dose IV TXA, 2.6 g/dl for double-dose IV TXA, 2.6 g/dl for combined IV/topical TXA, 2.9 g/dl for oral TXA; p = 0.38). Similarly, calculated blood loss (p = 0.65) and transfusion rates (p = 0.95) were not significantly different between groups. Equivalence testing assuming a 1 g/dl difference in haemoglobin change as clinically relevant showed that all possible pairings were statistically equivalent. Conclusion. Despite the higher risk of blood loss in revision TKA, all TXA regimens tested had equivalent blood-sparing properties. Surgeons should consider using the lowest effective dose and least costly TXA regimen in revision TKA. Cite this article: Bone Joint J 2019;101-B(Supple 7):10–16


The Bone & Joint Journal
Vol. 102-B, Issue 6 Supple A | Pages 116 - 122
1 Jun 2020
Bedard NA Cates RA Lewallen DG Sierra RJ Hanssen AD Berry DJ Abdel MP

Aims. Metaphyseal cones with cemented stems are frequently used in revision total knee arthroplasty (TKA). However, if the diaphysis has been previously violated, the resultant sclerotic canal can impair cemented stem fixation, which is vital for bone ingrowth into the cone, and long-term fixation. We report the outcomes of our solution to this problem, in which impaction grafting and a cemented stem in the diaphysis is combined with an uncemented metaphyseal cone, for revision TKA in patients with severely compromised bone. Methods. A metaphyseal cone was combined with diaphyseal impaction grafting and cemented stems for 35 revision TKAs. There were two patients with follow-up of less than two years who were excluded, leaving 33 procedures in 32 patients in the study. The mean age of the patients at the time of revision TKA was 67 years (32 to 87); 20 (60%) were male. Patients had undergone a mean of four (1 to 13) previous knee arthroplasty procedures. The indications for revision were aseptic loosening (80%) and two-stage reimplantation for prosthetic joint infection (PJI; 20%). The mean follow-up was four years (2 to 11). Results. Survival free from revision of the cone/impaction grafting construct due to aseptic loosening was 100% at five years. Survival free from any revision of the construct and free from any reoperation were 92% and 73% at five years, respectively. A total of six patients (six TKAs, 17%) required a further revision, four for infection or wound issues, and two for periprosthetic fracture. Radiologically, one unrevised TKA had evidence of loosening which was asymptomatic. In all unrevised TKAs the impacted diaphyseal bone graft appeared to be incorporated radiologically. Conclusion. When presented with a sclerotic diaphysis and substantial metaphyseal bone loss, this technique combining diaphyseal impaction grafting with a metaphyseal cone provided near universal success in relation to implant fixation. Moreover, radiographs revealed incorporation of the bone graft and biological fixation of the cone. While long-term follow-up will be important, this technique provides an excellent option for the management of complex revision TKAs. Cite this article: Bone Joint J 2020;102-B(6 Supple A):116–122


Bone & Joint Open
Vol. 4, Issue 5 | Pages 338 - 356
10 May 2023
Belt M Robben B Smolders JMH Schreurs BW Hannink G Smulders K

Aims. To map literature on prognostic factors related to outcomes of revision total knee arthroplasty (rTKA), to identify extensively studied factors and to guide future research into what domains need further exploration. Methods. We performed a systematic literature search in MEDLINE, Embase, and Web of Science. The search string included multiple synonyms of the following keywords: "revision TKA", "outcome" and "prognostic factor". We searched for studies assessing the association between at least one prognostic factor and at least one outcome measure after rTKA surgery. Data on sample size, study design, prognostic factors, outcomes, and the direction of the association was extracted and included in an evidence map. Results. After screening of 5,660 articles, we included 166 studies reporting prognostic factors for outcomes after rTKA, with a median sample size of 319 patients (30 to 303,867). Overall, 50% of the studies reported prospectively collected data, and 61% of the studies were performed in a single centre. In some studies, multiple associations were reported; 180 different prognostic factors were reported in these studies. The three most frequently studied prognostic factors were reason for revision (213 times), sex (125 times), and BMI (117 times). Studies focusing on functional scores and patient-reported outcome measures as prognostic factor for the outcome after surgery were limited (n = 42). The studies reported 154 different outcomes. The most commonly reported outcomes after rTKA were: re-revision (155 times), readmission (88 times), and reinfection (85 times). Only five studies included costs as outcome. Conclusion. Outcomes and prognostic factors that are routinely registered as part of clinical practice (e.g. BMI, sex, complications) or in (inter)national registries are studied frequently. Studies on prognostic factors, such as functional and sociodemographic status, and outcomes as healthcare costs, cognitive and mental function, and psychosocial impact are scarce, while they have been shown to be important for patients with osteoarthritis. Cite this article: Bone Jt Open 2023;4(5):338–356


The Bone & Joint Journal
Vol. 102-B, Issue 6 Supple A | Pages 107 - 115
1 Jun 2020
Tetreault MW Perry KI Pagnano MW Hanssen AD Abdel MP

Aims. Metaphyseal fixation during revision total knee arthroplasty (TKA) is important, but potentially difficult when using historical designs of cone. Material and manufacturing innovations have improved the size and shape of the cones which are available, and simplified the required bone preparation. In a large series, we assessed the implant survivorship, radiological results, and clinical outcomes of new porous 3D-printed titanium metaphyseal cones featuring a reamer-based system. Methods. We reviewed 142 revision TKAs in 139 patients using 202 cones (134 tibial, 68 femoral) which were undertaken between 2015 and 2016. A total of 60 involved tibial and femoral cones. Most cones (149 of 202; 74%) were used for Type 2B or 3 bone loss. The mean age of the patients was 66 years (44 to 88), and 76 (55 %) were female. The mean body mass index (BMI) was 34 kg/m. 2. (18 to 60). The patients had a mean of 2.4 (1 to 8) previous operations on the knee, and 68 (48%) had a history of prosthetic infection. The mean follow-up was 2.4 years (2 to 3.6). Results. Survivorship free of cone revision for aseptic loosening was 100% and survivorship free of any cone revision was 98%. Survivorships free of any revision and any reoperation were 90% and 83%, respectively. Five cones were revised: three for infection, one for periprosthetic fracture, and one for aseptic tibial loosening. Radiologically, three unrevised femoral cones appeared loose in the presence of hinged implants, while the remaining cones appeared stable. All cases of cone loosening occurred in patients with Type 2B or 3 defects. The mean Knee Society score (KSS) improved significantly from 50 (0 to 94) preoperatively to 87 (72 to 94) (p < 0.001). Three intraoperative fractures with cone impaction (two femoral, one tibial) healed uneventfully. Conclusion. Novel 3D-printed titanium cones, with a reamer-based system, yielded excellent early survivorship and few complications in patients with severe bone loss undergoing difficult revision TKA. The diversity of cone options, relative ease of preparation, and outcomes rivalling those of previous designs of cone support their continued use. Cite this article: Bone Joint J 2020;102-B(6 Supple A):107–115


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_9 | Pages 53 - 53
1 Oct 2020
Larson D Rosenberg J Lawlor M Garvin KL Hartman C Lyden E Konigsberg B
Full Access

Introduction. Revision total knee arthroplasty (TKA) is becoming increasingly common in the United States as the population ages and larger numbers of primary TKA are performed in younger individuals. Cemented or uncemented tibial stems are frequently used in revision cases. Decreased clinical outcomes and patient satisfaction have been described for revision TKA. This study aims to determine if the presence of overall pain and tibial pain at the end of the stem differs between cemented and uncemented tibial stems in revision TKA. Methods. This was a retrospective cohort study comparing patients who underwent revision TKA utilizing cemented or uncemented tibial stems in a 15-year period at a single institution with at least two-year follow-up. Exclusion criteria included age under 18, isolated revisions of the femoral component or polyethylene exchanges, lack of preoperative or postoperative imaging, insufficient operative or implant records available for electronic chart review, revision procedures performed at outside facilities, patients who were deceased at the time of survey administration, refusal to participate in the study, and failure to return the mailed survey or respond to a telephone follow-up questionnaire. Radiographic analysis included calculation of the percentage of the tibial canal filled with the implant, as well as measurement of the diameter of the tibial stem. Radiographs were also reviewed for evidence of cavitary defects, pedestal formation, radiolucent lines, and periprosthetic fractures. Mailed surveys addressing overall pain, tibial pain, and satisfaction were analyzed using Fisher's exact test and the independent sample t-test. Logistic regression was used to adjust for age, gender, and preoperative bone loss. Results. A total of 110 patients were included (63 cemented and 47 uncemented stems). No statistically significant differences in stem length, operative side, or indications for revision were found. The uncemented group had a significantly higher percent canal fill (p < 0.0001). Tibial pain at the end of the stem was present in 25.3% of cemented stems and 25.5% of uncemented stems (p = 1.00). There was a trend towards more overall pain in the uncemented cohort, but this did not reach statistical significance. Only 74.6% of cemented patients and 78.7% of uncemented patients were satisfied following revision TKA (p = 0.66). Conclusion. The data supports our hypothesis that there are no differences in end-of-stem pain or overall pain between cemented and uncemented tibial stems in revision TKA. High rates of dissatisfaction were noted in both cohorts postoperatively, consistent with previous literature. Patient factors likely play a large role in the presence of postoperative pain. These factors should be further evaluated in future studies in an effort to reduce pain and improve patient satisfaction


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 78 - 78
7 Aug 2023
Downie S Haque S Ridley D Nicol G Dalgleish S
Full Access

Abstract. Introduction. Revision total knee arthroplasty (rTKA) in elderly patients (>85 years) is associated with increased mortality, hospital stay and a high rate (55%) of complications. The objective was to assess PROMs in elderly patients undergoing rTKA. Methods. A retrospective cohort study of consecutive patients undergoing rTKA at an arthroplasty centre from 2001–2022 were compared to a control group (aged 50–79y) matched for gender, diagnosis & surgery year. The commonest reasons for revision in elderly patients was aseptic loosening (53/100), infection (21/100) and fracture (7/100). One-year patient-reported outcome data was available for 64%. Results. 100 patients underwent rTKA with a mean age of 84 years (range 80–97 years, SD 3) compared to a matched control group of younger patients (mean age 69y). Preoperative function was poor, with a mean Oxford knee score (OKS) of 40/100 in elderly and 43/100 in younger patients (p=0.164). At one-year postop, mean OKS was comparable between elderly and young patients (81 and 84/100 respectively, p=0.289). The number of patients with severe pain at one year was also comparable (4% elderly and 7% young respectively, p=0.177). The improvement in OKS for elderly patients was sustained at three (82 95% CI 58–100, 14/100 known) and five years. Overall complication rate was 54%. 14% were dead at 1 year and 56% were dead at five-years. Conclusion. Elderly patients undergoing elective revision TKA show a mean improvement in Oxford knee score of +38 at one year. This is the same as younger patients and is sustained at three and five years


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 39 - 39
1 Jul 2020
Mohamed N Castrodad I Etcheson J Gwam C George N Delanois R Jetty A Roadcloud E Elmallah R
Full Access

Revision total knee arthroplasty (TKA) procedures performed secondary to periprosthetic joint infection (PJI) are associated with significant morbidity and mortality. These poor outcomes may be further complicated by the development of postoperative infection requiring aggressive antibiotic treatment. However, this antibiotic overuse may suppress patients' native bacterial flora, leading to Clostridium difficile infection (CDI). With the increased demand for primary TKAs and expected rise in revision TKA due to PJI, it is important to identify factors contributing to CDI. Therefore, we aimed to study the: 1) incidence, 2) demographics, length of stay (LOS), and total costs, and 3) risk factors and mortality associated with CDI in revision TKA patients. The National Inpatient Sample database was queried for all individuals diagnosed with PJI and who underwent revision TKA between 2009 and 2013. Patients who developed CDI during their in-patient hospital stay were identified, yielding 83,806 patients (799 with CDI) with a mean age of 65 (S.D.=11.2). Logistic regression analysis was conducted to assess the association between hospital- and patient-specific characteristics and the development of CDI. During the study period, the overall incidence of CDI after revision TKA was 1%. These patients were significantly older (mean age 69.05 vs. 65.52 yrs), had greater LOS (median 11 vs. 5 days), had greater costs ($30,612.93 vs. 18,873.75), and had higher in-hospital mortality (3.6 vs. 0.5%, p < 0 .001 for all) compared to those without infection. Patients with CDI were more likely to be treated in urban, not-for-profit, medium or large bed-sized hospitals located in the Northeast or Midwest (p < 0 .05 for all). Patients with underlying depression (OR 4.267, p=0.007) or fluid/electrolyte disorders (OR 3.48, p=0.001) were more likely to develop infection. Although CDI is a rare event following revision TKA, it can have detrimental consequences. Our report demonstrates that CDI is associated with longer LOS, higher costs, and greater in-hospital mortality. With increased legislative pressure to lower healthcare expenditures, it is crucial to identify means of preventing costly complications


Bone & Joint Research
Vol. 6, Issue 3 | Pages 172 - 178
1 Mar 2017
Clement ND MacDonald DJ Hamilton DF Burnett R

Objectives. Preservation of posterior condylar offset (PCO) has been shown to correlate with improved functional results after primary total knee arthroplasty (TKA). Whether this is also the case for revision TKA, remains unknown. The aim of this study was to assess the independent effect of PCO on early functional outcome after revision TKA. Methods. A total of 107 consecutive aseptic revision TKAs were performed by a single surgeon during an eight-year period. The mean age was 69.4 years (39 to 85) and there were 59 female patients and 48 male patients. The Oxford Knee Score (OKS) and Short-form (SF)-12 score were assessed pre-operatively and one year post-operatively. Patient satisfaction was also assessed at one year. Joint line and PCO were assessed radiographically at one year. Results. There was a significant improvement in the OKS (10.6 points, 95% confidence interval (CI) 8.8 to 12.3) and the SF-12 physical component score (5.9, 95% CI 4.1 to 7.8). PCO directly correlated with change in OKS (p < 0.001). Linear regression analysis confirmed the independent effect of PCO on the OKS (p < 0.001) and the SF-12 physical score (p = 0.02). The overall rate of satisfaction was 85% and on logistic regression analysis improvement in the OKS (p = 0.002) was a significant predictor of patient satisfaction, which is related to PCO; although this was not independently associated with satisfaction. Conclusion. Preservation of PCO should be a major consideration when undertaking revision TKA. The option of increasing PCO to balance the flexion gap while maintaining the joint line should be assessed intra-operatively. Cite this article: N. D. Clement, D. J. MacDonald, D. F. Hamilton, R. Burnett. Posterior condylar offset is an independent predictor of functional outcome after revision total knee arthroplasty. Bone Joint Res 2017;6:172–178. DOI: 10.1302/2046-3758.63.BJR-2015-0021.R1


Bone & Joint Research
Vol. 9, Issue 4 | Pages 162 - 172
1 Apr 2020
Xie S Conlisk N Hamilton D Scott C Burnett R Pankaj P

Aims. Metaphyseal tritanium cones can be used to manage the tibial bone loss commonly encountered at revision total knee arthroplasty (rTKA). Tibial stems provide additional fixation and are generally used in combination with cones. The aim of this study was to examine the role of the stems in the overall stability of tibial implants when metaphyseal cones are used for rTKA. Methods. This computational study investigates whether stems are required to augment metaphyseal cones at rTKA. Three cemented stem scenarios (no stem, 50 mm stem, and 100 mm stem) were investigated with 10 mm-deep uncontained posterior and medial tibial defects using four loading scenarios designed to mimic activities of daily living. Results. Small micromotions (mean < 12 µm) were found to occur at the bone-implant interface for all loading cases with or without a stem. Stem inclusion was associated with lower micromotion, however these reductions were too small to have any clinical significance. Peak interface micromotion, even when the cone is used without a stem, was too small to effect osseointegration. The maximum difference occurred with stair descent loading. Stress concentrations in the bone occurred around the inferior aspect of each implant, with the largest occurring at the end of the long stem; these may lead to end-of-stem pain. Stem use is also found to result in stress shielding in the bone along the stem. Conclusion. When a metaphyseal cone is used at rTKA to manage uncontained posterior or medial defects of up to 10 mm depth, stem use may not be necessary. Cite this article:Bone Joint Res. 2020;9(4):162–172


The Bone & Joint Journal
Vol. 103-B, Issue 4 | Pages 602 - 609
1 Apr 2021
Yapp LZ Walmsley PJ Moran M Clarke JV Simpson AHRW Scott CEH

Aims. The aim of this study was to measure the effect of hospital case volume on the survival of revision total knee arthroplasty (RTKA). Methods. This is a retrospective analysis of Scottish Arthroplasty Project data, a nationwide audit which prospectively collects data on all arthroplasty procedures performed in Scotland. The primary outcome was RTKA survival at ten years. The primary explanatory variable was the effect of hospital case volume per year on RTKA survival. Kaplan-Meier survival curves were plotted with 95% confidence intervals (CIs) to determine the lifespan of RTKA. Multivariate Cox proportional hazards were used to estimate relative revision risks over time. Hazard ratios (HRs) were reported with 95% CI, and p-value < 0.05 was considered statistically significant. Results. From 1998 to 2019, 8,301 patients (8,894 knees) underwent RTKA surgery in Scotland (median age at RTKA 70 years (interquartile range (IQR) 63 to 76); median follow-up 6.2 years (IQR 3.0 to 10.2). In all, 4,764 (53.6%) were female, and 781 (8.8%) were treated for infection. Of these 8,894 knees, 957 (10.8%) underwent a second revision procedure. Male sex, younger age at index revision, and positive infection status were associated with need for re-revision. The ten-year survival estimate for RTKA was 87.3% (95% CI 86.5 to 88.1). Adjusting for sex, age, surgeon volume, and indication for revision, high hospital case volume was significantly associated with lower risk of re-revision (HR 0.78 (95% CI 0.64 to 0.94, p < 0.001)). The risk of re-revision steadily declined in centres performing > 20 cases per year; risk reduction was 16% with > 20 cases; 22% with > 30 cases; and 28% with > 40 cases. The lowest level of risk was associated with the highest volume centres. Conclusion. The majority of RTKA in Scotland survive up to ten years. Increasing yearly hospital case volume above 20 cases is independently associated with a significant risk reduction of re-revision. Development of high-volume tertiary centres may lead to an improvement in the overall survival of RTKA. Cite this article: Bone Joint J 2021;103-B(4):602–609


The Bone & Joint Journal
Vol. 104-B, Issue 7 | Pages 875 - 883
1 Jul 2022
Mills K Wymenga AB van Hellemondt GG Heesterbeek PJC

Aims. Both the femoral and tibial component are usually cemented at revision total knee arthroplasty (rTKA), while stems can be added with either cemented or press-fit (hybrid) fixation. The aim of this study was to compare the long-term stability of rTKA with cemented and press-fitted stems, using radiostereometric analysis (RSA). Methods. This is a follow-up of a randomized controlled trial, initially involving 32 patients, of whom 19 (nine cemented, ten hybrid) were available for follow-up ten years postoperatively, when further RSA measurements were made. Micromotion of the femoral and tibial components was assessed using model-based RSA software (RSAcore). The clinical outcome was evaluated using the Knee Society Score (KSS), the Knee injury and Osteoarthritis Outcome Score (KOOS), and visual analogue scale (pain and satisfaction). Results. The median total femoral translation and rotation at ten years were 0.39 mm (interquartile range (IQR) 0.20 to 0.54) and 0.59° (IQR 0.46° to 0.73°) for the cemented group and 0.70 mm (IQR 0.15 to 0.77) and 0.78° (IQR 0.47° to 1.43°) for the hybrid group. For the tibial components this was 0.38 mm (IQR 0.33 to 0.85) and 0.98° (IQR 0.38° to 1.34°) for the cemented group and 0.42 mm (IQR 0.30 to 0.52) and 0.72° (IQR 0.62° to 0.82°) for the hybrid group. None of these values were significantly different between the two groups and there were no significant differences between the clinical scores in the two groups at this time. There was only one re-revision, in the hybrid group, for infection and not for aseptic loosening. Conclusion. These results show good long-term fixation with no difference in micromotion and clinical outcome between fully cemented and hybrid fixation in rTKA, which builds on earlier short- to mid-term results. The patients all had type I or II osseous defects, which may in part explain the good results. Cite this article: Bone Joint J 2022;104-B(7):875–883


The Bone & Joint Journal
Vol. 103-B, Issue 8 | Pages 1373 - 1379
1 Aug 2021
Matar HE Bloch BV Snape SE James PJ

Aims. Single-stage revision total knee arthroplasty (rTKA) is gaining popularity in treating chronic periprosthetic joint infections (PJIs). We have introduced this approach to our clinical practice and sought to evaluate rates of reinfection and re-revision, along with predictors of failure of both single- and two-stage rTKA for chronic PJI. Methods. A retrospective comparative cohort study of all rTKAs for chronic PJI between 1 April 2003 and 31 December 2018 was undertaken using prospective databases. Patients with acute infections were excluded; rTKAs were classified as single-stage, stage 1, or stage 2 of two-stage revision. The primary outcome measure was failure to eradicate or recurrent infection. Variables evaluated for failure by regression analysis included age, BMI, American Society of Anesthesiologists grade, infecting organisms, and the presence of a sinus. Patient survivorship was also compared between the groups. Results. A total of 292 consecutive first-time rTKAs for chronic PJI were included: 82 single-stage (28.1%); and 210 two-stage (71.9%) revisions. The mean age was 71 years (27 to 90), with 165 females (57.4%), and a mean BMI of 30.9 kg/m. 2. (20 to 53). Significantly more patients with a known infecting organism were in the single-stage group (93.9% vs 80.47%; p = 0.004). The infecting organism was identified preoperatively in 246 cases (84.2%). At a mean follow-up of 6.3 years (2.0 to 17.6), the failure rate was 6.1% in the single-stage, and 12% in the two-stage groups. All failures occurred within four years of treatment. The presence of a sinus was an independent risk factor for failure (odds ratio (OR) 4.97; 95% confidence interval (CI) 1.593 to 15.505; p = 0.006), as well as age > 80 years (OR 5.962; 95% CI 1.156 to 30.73; p = 0.033). The ten-year patient survivorship rate was 72% in the single-stage group compared with 70.5% in the two-stage group. This difference was not significant (p = 0.517). Conclusion. Single-stage rTKA is an effective strategy with a high success rate comparable to two-stage approach in appropriately selected patients. Cite this article: Bone Joint J 2021;103-B(8):1373–1379


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 106 - 106
1 Jul 2020
Dion C Lanting B Howard J Teeter M Willing R
Full Access

During revision total knee arthroplasty (rTKA), proximal tibial bone loss is frequently encountered and can result in a less-stable bone-implant fixation. A 3D printed titanium alloy (Ti6Al4V) revision augment that conforms to the irregular shape of the proximal tibia was recently developed. The purpose of this study was to evaluate the fixation stability of rTKA with this augment in comparison to conventional cemented rTKA. Eleven pairs of thawed fresh-frozen cadaveric tibias (22 tibias) were potted in custom fixtures. Primary total knee arthroplasty (pTKA) surgery was performed on all tibias. Fixation stability testing was conducted using a three-stage eccentric loading protocol. Static eccentric (70% medial/ 30% lateral) loading of 2100 N was applied to the implants before and after subjecting them to 5×103 loading cycles of 700 N at 2 Hz using a joint motion simulator. Bone-implant micromotion was measured using a high-resolution optical system. The pTKA were removed. The proximal tibial bone defect was measured. One tibia from each pair was randomly allocated to the experimental group, and rTKA was performed with a titanium augment printed using selective laser melting. The contralateral side was assigned to the control group (revision with fully cemented stems). The three-stage eccentric loading protocol was used to test the revision TKAs. Independent t-tests were used to compare the micromotion between the two groups. After revision TKA, the mean micromotion was 23.1μm ± 26.2μm in the control group and 12.9μm ± 22.2μm in the experimental group. There was significantly less micromotion in the experimental group (p= 0.04). Prior to revision surgery, the control and experimental group had no significant difference in primary TKA micromotion (p= 0.19) and tibial bone loss (p= 0.37). This study suggests that early fixation stability of revision TKA with the novel 3D printed titanium augment is significantly better then the conventional fully cemented rTKA. The early press-fit fixation of the augment is likely sufficient for promoting bony ingrowth of the augment in vivo. Further studies are needed to investigate the long-term in-vivo fixation of the novel 3D printed augment


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_9 | Pages 57 - 57
1 Oct 2020
Zois TP Bohm A Mont M Scuderi GR
Full Access

Background. Revision total knee arthroplasty (rTKA) is a complex procedure with increased risk of blood loss and transfusions. The Musculoskeletal Infection Society has included D-dimer as a serology marker for peri-prosthetic infection. The study's intent is to understand the impact of preoperative D-dimer levels on blood loss and venous thromboembolism in revision TKA. Methods. Following IRB approval, rTKA performed by a single surgeon between January 1, 2017 and December 31, 2019 were reviewed. Inclusion criteria consisted of pre-operative D-Dimer, cemented revision TKA of one or both components under tourniquet control. 89 patients met the criteria including 37 males (41.6%) and 52 females (58.4%). Mean ages were 65 for males and 67 for females. The data revealed 54 patients (61%) had an elevated D-dimer (group 1) and 35 patients (39%) had a normal D-dimer (group 2). Sex stratification showed 21 males (57.8%) and 33 females (63.5%) with elevated D-dimer. TXA protocol included 2 grams intravenous (82 patients) or 2 grams intra-articular application (7 patients). Post-operative anticoagulation included Lovenox 40mg daily for 2 weeks followed by aspirin 325 twice daily for 4 weeks. Pre-operative and post-operative hemoglobin, transfusion rates and post-operative VTE within 90 days of surgery were recorded. Results. The mean pre-operative hemoglobin (hgb) was 13.30 and post-operative was 11.21. The mean change in hgb for males was 2.75 and for females 1.91. Both male and female cohorts had an acceptable range and the change in hgb was not statistically significant (p=0.076). Two female patients (2.25%) were transfused, both receiving IV TXA and their pre-operative hgb was lower than the cohort. No VTE events were identified in either groups of patients within the 90 day post-operative period. Conclusion. This study revealed that TXA is effective in reducing blood loss following rTKA and an elevated D-dimer is not a contraindication to its use


The Bone & Joint Journal
Vol. 103-B, Issue 6 Supple A | Pages 131 - 136
1 Jun 2021
Roof MA Sharan M Merkow D Feng JE Long WJ Schwarzkopf RS

Aims. It has previously been shown that higher-volume hospitals have better outcomes following revision total knee arthroplasty (rTKA). We were unable to identify any studies which investigated the effect of surgeon volume on the outcome of rTKA. We sought to investigate whether patients of high-volume (HV) rTKA surgeons have better outcomes following this procedure compared with those of low-volume (LV) surgeons. Methods. This retrospective study involved patients who underwent aseptic unilateral rTKA between January 2016 and March 2019, using the database of a large urban academic medical centre. Surgeons who performed ≥ 19 aseptic rTKAs per year during the study period were considered HV and those who performed < 19 per year were considered LV. Demographic characteristics, surgical factors, and postoperative outcomes were compared between the two groups. Results. A total of 308 rTKAs were identified, 132 performed by HV surgeons and 176 by 22 LV surgeons. The LV group had a significantly greater proportion of non-smokers (59.8% vs 49.2%; p = 0.029). For all types of revision, HV surgeons had significantly shorter mean operating times by 17.75 minutes (p = 0.007). For the 169 full revisions (85 HV, 84 LV), HV surgeons had significantly shorter operating times (131.12 (SD 33.78) vs 171.65 (SD 49.88) minutes; p < 0.001), significantly lower re-revision rates (7.1% vs 19.0%; p = 0.023) and significantly fewer re-revisions (0.07 (SD 0.26) vs 0.29 (SD 0.74); p = 0.017). Conclusion. Patients of HV rTKA surgeons have better outcomes following full rTKA. These findings support the development of revision teams within arthroplasty centres of excellence to offer patients the best possible outcomes following rTKA. Cite this article: Bone Joint J 2021;103-B(6 Supple A):131–136


Aims. The aim of this study was to evaluate medium-term outcomes and complications of the S-ROM NOILES Rotating Hinge Knee System (DePuy, USA) in revision total knee arthroplasty (rTKA) at a tertiary unit. Methods. A retrospective consecutive study of all patients who underwent a rTKA using this implant from January 2005 to December 2018. Outcome measures included reoperations, revision for any cause, complications, and survivorship. Patients and implant survivorship data were identified through both local hospital electronic databases and linked data from the National Joint Registry/NHS Personal Demographic Service. Kaplan-Meier survival analysis was used at ten years. Results. A total of 89 consecutive patients (89 knees) were included with 47 females (52.8%) and a median age of 74 years (interquartile range 66 to 79). The main indications were aseptic loosening with instability (39.4%; n = 35) and infection (37.1%; n = 33) with the majority of patients managed through two-stage approach. The mean follow-up was 7.4 years (2 to 16). The overall rate of reoperation, for any cause, was 10.1% (n = 9) with a rate of implant revision of 6.7% (n = 6). Only two cases required surgery for patellofemoral complications. Kaplan-Meier implant-survivorship analysis was 93.3% at ten years, using revision for any cause as an endpoint. Conclusion. This implant achieved high ten-year survivorship with a low complication rate, particularly patellofemoral complications. These can be avoided by ensuring central patella tracking and appropriate tension of the patellofemoral joint in this posterior hinge design. Cite this article: Bone Jt Open 2022;3(3):205–210


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_15 | Pages 55 - 55
1 Dec 2021
Klim S Clement H Amerstorfer F Leitner L Leithner A Glehr M
Full Access

Aim. To improve the challenging treatment of periprosthetic joint infections (PJI), researchers are constantly developing new handling methods and strategies. In patients with PJI after total knee arthroplasty (TKA) and severe local or systemic comorbidities, a two-stage exchange using a temporary antibiotic loaded PMMA-spacer is considered gold standard. This method has undisputed advantages, however, the increased risk of biofilm formation on the spacer surface, bone defects and soft tissue contractions after a six-week spacer interval are severe limitations. Our hypothesis is that a vacuum sealed foam in combination with constant instillation of an antiseptic fluid can address these drawbacks due to a significantly reduced spacer interval. Method. A pilot study was conducted in five PJI cases after TKA with severe comorbidities and/or multiple previous operations to evaluate the feasibility and safety of the proposed method. In the first step, surgical treatment included the explantation of the prosthesis, debridement, and the implantation of the VeraFlo-Dressing foam. The foam is connected to the VAC-Instill-Device via an inflow and an outflow tube. The surgical site is sealed airtight with the VAC-film. During the next 5 days, an antiseptic fluid (Lavasorb® or Taurolidine®) is instilled in a 30-minute interval using the VAC-Instill-Device. The limb is immobilized (no flexion in the knee joint, no weight bearing) for five days. Following that, the second operation is performed in which the VAC-VeraFlo. TM. -Therapy System is explanted and the revision TKA is implanted after debridement of the joint. Results. No serious adverse event occurred during the VAC-Instill spacer treatment. The TKA revision was performed after a mean of 5.4 ± 1.9 days. Mean patient age was 71±6 years with a mean of 6 previous PJI surgeries. Host classification according to McPherson was I/B/3, III/B/3 and III/C/3 in three cases. Out of the five cases included, four were successfully treated and remained infect free to date (mean 14.2 ± 12 months; germs: methicillin-resistant s. aureus, e. coli, staph. lugdunensis and one culture neg.). One case with candida infection of a total femur prosthesis had to be treated with an enucleation of the hip due to rising inflammation parameters and signs of sepsis 7 days after VAC-Instill implantation. Conclusions. The presented data on the VAC-Instill spacer method in septic two-stage revision TKA show promising results regarding feasibility and safety. A prospective randomized controlled examination is in progress to evaluate the possible advantages over a two-stage approach using a standard PMMA spacer


Bone & Joint Open
Vol. 2, Issue 8 | Pages 576 - 582
2 Aug 2021
Fuchs M Kirchhoff F Reichel H Perka C Faschingbauer M Gwinner C

Aims. Current guidelines consider analyses of joint aspirates, including leucocyte cell count (LC) and polymorphonuclear percentage (PMN%) as a diagnostic mainstay of periprosthetic joint infection (PJI). It is unclear if these parameters are subject to a certain degree of variability over time. Therefore, the aim of this study was to evaluate the variation of LC and PMN% in patients with aseptic revision total knee arthroplasty (TKA). Methods. We conducted a prospective, double-centre study of 40 patients with 40 knee joints. Patients underwent joint aspiration at two different time points with a maximum period of 120 days in between these interventions and without any events such as other joint aspirations or surgeries. The main indications for TKA revision surgery were aseptic implant loosening (n = 24) and joint instability (n = 11). Results. Overall, 80 synovial fluid samples of 40 patients were analyzed. The average time period between the joint aspirations was 50 days (SD 32). There was a significantly higher percentage change in LC when compared to PMN% (44.1% (SD 28.6%) vs 27.3% (SD 23.7%); p = 0.003). When applying standard definition criteria, LC counts were found to skip back and forth between the two time points with exceeding the thresholds in up to 20% of cases, which was significantly more compared to PMN% for the European Bone and Joint Infection Society (EBJIS) criteria (p = 0.001), as well as for Musculoskeletal Infection Society (MSIS) (p = 0.029). Conclusion. LC and PMN% are subject to considerable variation. According to its higher interindividual variance, LC evaluation might contribute to false-positive or false-negative results in PJI assessment. Single LC testing prior to TKA revision surgery seems to be insufficient to exclude PJI. On the basis of the obtained results, PMN% analyses overrule LC measurements with regard to a conclusive diagnostic algorithm. Cite this article: Bone Jt Open 2021;2(8):566–572


The Bone & Joint Journal
Vol. 103-B, Issue 6 Supple A | Pages 150 - 157
1 Jun 2021
Anderson LA Christie M Blackburn BE Mahan C Earl C Pelt CE Peters CL Gililland J

Aims. Porous metaphyseal cones can be used for fixation in revision total knee arthroplasty (rTKA) and complex TKAs. This metaphyseal fixation has led to some surgeons using shorter cemented stems instead of diaphyseal engaging cementless stems with a potential benefit of ease of obtaining proper alignment without being beholden to the diaphysis. The purpose of this study was to evaluate short term clinical and radiographic outcomes of a series of TKA cases performed using 3D-printed metaphyseal cones. Methods. A retrospective review of 86 rTKAs and nine complex primary TKAs, with an average age of 63.2 years (SD 8.2) and BMI of 34.0 kg/m. 2. (SD 8.7), in which metaphyseal cones were used for both femoral and tibial fixation were compared for their knee alignment based on the type of stem used. Overall, 22 knees had cementless stems on both sides, 52 had cemented stems on both sides, and 15 had mixed stems. Postoperative long-standing radiographs were evaluated for coronal and sagittal plane alignment. Adjusted logistic regression models were run to assess malalignment hip-knee-ankle (HKA) alignment beyond ± 3° and sagittal alignment of the tibial and femoral components ± 3° by stem type. Results. No patients had a revision of a cone due to aseptic loosening; however, two had revision surgery due to infection. In all, 26 (27%) patients had HKA malalignment; nine (9.5%) patients had sagittal plane malalignment, five (5.6%) of the tibia, and four (10.8%) of the femur. After adjusting for age, sex, and BMI, there was a significantly increased risk for malalignment when a cone was used and both the femur and tibia had cementless compared to cemented stems (odds ratio 3.19, 95% confidence interval 1.01 to 10.05). Conclusion. Porous 3D-printed cones provide excellent metaphyseal fixation. However, these central cones make the use of offset couplers difficult and may generate malalignment with cementless stems. We found 3.19-times higher odds of malalignment in our TKAs performed with metaphyseal cones and both femoral and tibial cementless stems. Cite this article: Bone Joint J 2021;103-B(6 Supple A):150–157


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_5 | Pages 45 - 45
1 Apr 2018
Yoon C Chang C Chang M Shin J Song M Kang S
Full Access

Background. Joint line, patellar height and posterior condylar offset (PCO) are related to functional outcome such as stability and range of motion after revision total knee arthroplasty (TKA). The purpose of this study was (1) to determine whether revision TKA can restore the joint line, patella height and condylar offset after surgery, and (2) to assess factors associated with failed restoration. Materials and Methods. We retrospectively reviewed 27 consecutive patients who underwent revision TKA. Among 27 patients, 11 patients had two-stage revision TKA due to periprosthetic joint infection while 14 patients underwent revision TKA due to aseptic loosening. In addition, there were 2 patients who had traumatic event causing a periprosthetic fracture which led to revision TKA. The joint line was measured using the distance from the adductor tubercle of the femur to the most distal portion of the medial femoral component on knee anterior-posterior radiographs. Patella height was assessed using the Caton-Deschamps method. In addition, PCO were measured relative to the tangent of the posterior cortex of the femur using knee lateral radiograph. All parameters were compared between pre- and postoperative radiographs after revision TKA. Results. After revision TKA, mean joint line elevation was 0.9 mm. Seven of 27 patients showed joint line elevation of 5 mm or more. There was no significant difference between pre- and postoperative PCO (27.6 mm and 28.1 mm, respectively; P = 0.528). Fifteen patients (56%) showed patellar baja after revision TKA. Compared to the patients with aseptic loosening, the patients with periprosthetic joint infection or fracture showed greater joint line elevation (4.1 mm and −2.2 mm, respectively; P < 0.01), smaller PCO change (1.9 mm and −1.1 mm respectively, P < 0.05). Even if the cause of revision TKA was not associated with the postoperative patellar baja, presence of preoperative patellar baja was significantly associated with postoperative patellar baja (P < 0.05). Conclusions. Overall, restoration of the joint line and PCO were achieved in contemporary revision TKA. However, the patients who underwent revision TKA due to periprosthetic joint infection or fracture showed greater joint line elevation as well as smaller PCO. In addition, the patellar height was not improved in patients with preoperative patellar baja. Further evaluation of functional outcome is needed to assess correlation between radiological and functional outcome


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 38 - 38
10 Feb 2023
Batinica B Bolam S Zhu M D'Arcy M Peterson R Young S Monk A Munro J
Full Access

Little information exists regarding optimal tibial stem usage in revision total knee arthroplasty (rTKA) utilising a tibial trabecular metal (TM) cone. The purpose of this study was to compare 1) functional outcomes, 2) radiographic outcomes, and 3) implant survivorship in rTKA utilising TM cones combined with either short stems (SS) or long stems (LS) at minimum two-years clinical follow-up. In this retrospective, multi-centre study, patients undergoing TM cone utilising rTKA between 2008 and 2019 were included. Patients were divided into: SS group (no diaphyseal engagement), and LS group (diaphyseal engagement). All relevant clinical charts and post-operative radiographs were examined. Oxford Knee Score (OKS) and EuroQol-5D (EQ-5D-5L) data were collected at most recent follow-up. In total, 44 patients were included: 18 in the SS group and 26 in the LS group. The mean time of follow-up was 4.0 years. Failure free survival was 94.5% for the SS group and 92.3% for the LS group. All failures were for prosthetic joint infections managed with debridement, antibiotics, and implant retention. At most recent follow-up, 3 patients demonstrated radiographic signs of lucency (1 SS 2 LS, p = 1) and the mean OKS were 37 ± 4 and 36 ± 6 (p = 0.73) in the SS and LS groups, respectively. Tibial SS combined with TM cones performed as well as LS in rTKA at minimum two-years follow-up. A tibial SS in combination with a TM cone is a reliable technique to achieve stable and durable fixation in rTKA


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_11 | Pages 28 - 28
1 Oct 2019
Warchawski Y Garceau S Dahduli O Wolfstadt JI Backstein D
Full Access

Background. Patellar dislocation is a serious complication leading to patient morbidity following total knee arthroplasty. The cause can be multifactorial. Extensor mechanism imbalance may be present and result from technical errors such as malrotation of the implants. Methods. We performed a retrospective study assessing the outcomes of revision surgery for patellar dislocation in patients with component malrotation in both primary and revision total knee arthroplasty. Patient demographics, etiology of dislocation, presurgical deformity, intraoperation component position, complications, reoperation and knee society scores were collected. Results. Twenty patients (twenty-one knees) were identified. The average time from primary arthroplasty to onset of dislocation was 33.6 months (SD, 44.4), and the average time from dislocation to revision was 3.38 months (SD, 2.81). Seventeen knees (80.1%) had internal rotation of the tibial component and 7 knees (33.3%) had combined internal rotation of both the femoral and tibial components. Sixteen knees (76.1%) were treated with a condylar constrained implant at the time of revision, and 5 knees were converted to a hinged prosthesis. The average follow-up time was 56 months. During this time, one patient (4.54%) had a recurrent dislocation episode, requiring further surgery. At final follow up, the mean knee society score for the patient cohort was 86.2. Conclusion. Revision total knee arthroplasty to treat patellar dislocation in patients with malrotated components was associated with high success rates. After revision surgery, patients had a low recurrence of patellar dislocation, low complication rates, and excellent functional outcomes. For figures, tables, or references, please contact authors directly


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_2 | Pages 28 - 28
1 Mar 2021
Bruce D Murray J Whitehouse M Seminati E Preatoni E
Full Access

Abstract. Objectives. 1. To investigate the effect of revision total knee replacement (TKR) on gait kinematics in patients with a primary TKR and instability.2. To compare gait kinematics between patients with a well-functioning TKR and those with a primary TKR and symptoms of instability. Methods. This single-centre observational study is following patients who have had a revision TKR due to knee instability. Data was collected pre- and post-operatively at 8–12 week follow-up. The data was compared to a control group of 18 well-functioning TKR patients. Kinematic gait data was collected during routine clinics using a treadmill-based infrared 3D system (Vicon, Oxford, UK) and a published lower limb marker-set. Patients performed 15 strides at three different speeds: 0.6mph, self-selected, and a ‘slow walk’ normalised to leg length (Froude number 0.09). PROMs questionnaires were collected. NHS ethical approval was obtained. Results. Data was collected for 18 well-functioning TKR patients and 8 revision TKR patients pre- and post-operatively, but only 5 could walk at the normalised speed. When walking at a normalised speed (Froude 0.09), patients with a TKR with instability had reduced range of knee flexion (52° (sd 14)) compared to those with a well-functioning TKR (59° (sd 11)). Short term follow-up after a revision TKR operation demonstrated a stiffer knee (45° (sd 12)). However, those with revision TKR had a more flexed knee during stance phase. Conclusions. At short-term follow-up, this cohort of revision TKR patients appear to have reduced flexion range, while remaining more flexed during stance. This may represent a less efficient gait pattern, which may also adversely affect the implant[1]. Longer term follow-up may demonstrate whether this normalises with post-operative rehabilitation. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_8 | Pages 67 - 67
1 May 2019
Lewallen D
Full Access

The amount of bone loss due to implant failure, loosening, or osteolysis can vary greatly and can have a major impact on reconstructive options during revision total knee arthroplasty (TKA). Massive bone loss can threaten ligamentous attachments in the vicinity of the knee and may require use of components with additional constraint to compensate for associated ligamentous instability. Classification of bone defects can be helpful in predicting the complexity of the reconstruction required and in facilitating preoperative planning and implant selection. One very helpful classification of bone loss associated with TKA is the Anderson Orthopaedic Research Institute (AORI) Bone Defect Classification System as it provides the means to compare the location and extent of femoral and tibial bone loss encountered during revision surgery. In general, the higher grade defects (Type IIb or III) on both the femoral and tibial sides are more likely to require stemmed components, and may require the use of either structural graft or large augments to restore support for currently available modular revision components. Custom prostheses were previously utilised for massive defects of this sort, but more recently have been supplanted by revision TKA component systems with or without special metal augments or structural allograft. Options for bone defect management are: 1) Fill with cement; 2) Fill with cement supplemented by screws or K-wires; 3) Morselised bone grafting (for smaller, especially contained cavitary defects); 4) Small segment structural bone graft; 5) Impaction grafting; 6) Porous metal cones or sleeves 7) Massive structural allograft-prosthetic composites; 8) Custom implants. Of these, use of uncemented highly porous metal metaphyseal cones in combination with an initial cemented or partially cemented implant has been shown to provide versatile and highly durable results for a range of bone defects including those previously requiring structural bone graft. The hybrid fixation combination of both cement and cementless fixation of an individual tibial or femoral component has emerged as a frequent and often preferred technique. Initial secure and motionless interfaces are provided by the cemented portions of the construct, while subsequent bone ingrowth to the cementless porous metal portions is the key to long term stable fixation. As bone grows into the porous portions there is off loading and protection of the cemented interfaces from mechanical stresses. While maximizing support on intact host bone has been a longstanding fundamental principle of revision arthroplasty, this is facilitated by the use of metaphyseal cones or sleeves in combination with initial fixation into the adjacent diaphysis. Preoperative planning is facilitated by good quality radiographs, supplemented on occasion by additional imaging such as CT. Fluoroscopically controlled x-ray views may assist in diagnosing the loose implant by better revealing the interface between the implant and bone and can facilitate accurate delineation of the extent of bone deficiency present. Part of the preoperative plan is to ensure adequate range and variety of implant choices and bone graft resources for the planned reconstruction allowing for the potential for unexpected intraoperative findings such as occult fracture through deficient periprosthetic bone. While massive bone loss may compromise ligamentous attachment to bone, in the majority of reconstructions, the degree of revision implant constraint needed for proper balancing and restoration of stability is independent of the bone defect. Thus, some knees with minimal bone deficiency may require increased constraint due to the status of the soft tissues while others involving very large bone defects, especially of the cavitary sort, may be well managed with minimal constraint


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_8 | Pages 61 - 61
1 Aug 2020
Jean P Belzile E Pelet S Caron J
Full Access

Over the last decade, the number of total knee arthroplasty (TKA) has risen over 125%. Numerous studies have established a relationship between obesity and complications in primary TKA. Interestingly, few studies have investigated medical and orthopaedic complications in obese patients undergoing revision TKA (RTKA). With the increasing number of RTKA and with the prevalence of obesity still on the rise, the study of obesity on complications following RTKA is indicated. We retrospectively reviewed 180 RTKA performed by a single surgeon done between August 2008 and June 2017. All patients who underwent RTKA were included, but revisions done with simultaneous extensor mechanism reconstruction and/or distal femur replacement were excluded since these procedures are technically more demanding. 154 revisions met our inclusion/exclusion criteriaes and were included in the final analysis. 81 patients were included in the non-obese group (BMI . The total number of orthopaedic complications in the obese group (46.6%) was significantly higher than in the non-obese group (27.2%) (OR=1.71) (p = 0.01). The number of infection was higher in the obese group (11%) than in the non-obese (6.2%) but this was not statistically significant (OR=1.77) (p = 0.28). Reoperation rate was also higher in the obese group (23.3%) than in the non-obese group (16%) but this did not reach statistical significance (OR=1.46) (p = 0.26) (Table 3). Medical complications were higher in the obese group (31.5% vs 19.8%) (OR=1.59) (p=0.09). According to the Dindo-Clavien classification, the obese group demonstrated a significantly higher rate of grade 3 or higher complications (p = 0.01). Obesity significantly increases the occurrence of orthopaedic complications following RTKA. Obesity also seems to increase the number of medical complications following RTKA. The obese patient should be informed prior to revision TKA that there is an increased risk of complications when compared with the non-obese patient. Further research with higher power would seem advisable to confirm this trend. For any figures or tables, please contact the authors directly


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_2 | Pages 92 - 92
1 Feb 2020
Chun K Kwon H Kim K Chun C
Full Access

Purpose. The aim of this study was to compare the clinical outcomes of the revision TKA in which trabecular metal cones and femoral head allografts were used for large bone defect. Method. Total 53 patients who have undergone revision TKA from July 2013 to March 2017 were enrolled in this study. Among them, 24 patients used trabecular metal cones, and 29 patients used femoral head allografts for large bone defect. There were 3 males and 21 females in the metal cone group, while there were 4 males and 25 females in the allograft group. The mean age was 70.2 years (range, 51–80) in the femoral head allograft group, while it was 79.1 years (range, 73–85) in the metal cone group. Bone defect is classified according to the AORI classification and clinical outcomes were evaluated with Visual Analogue Scale (VAS), Hospital Special Surgery-score (HSS), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), Knee Injury and Osteoarthritis Outcome Score (KOOS), and ROM. Operation time was also evaluated. We used radiographs to check complications such as migration or loosening. We took follow-up x-rays and 3D CT of the patients, to assess the mean bone union period. Shapiro-Wilk test was done to check normality and Student T-test and Mann Whitney U-test were done for comparison between two groups. Result. The mean follow-up period was 3 .75 years (Range; 2.1 ∼ 5.75). The pre-op scores did not show significant difference. The mean VAS in the allograft and trabecular metal cone groups was 2.1 ± 0.87 and 1.8 ± 0.53, respectively (p = 0.16). The mean HSS score were 76.3 ± 5.51 and 79.2 ± 4.12 respectively (p = 0.13) and the mean WOMAC scores were 15.1 ± 3.25 and 14.8 ± 3.31 respectively (p = 0.06), and the mean KOOS scores were 27.8 ± 4.77 and 25.5 ± 4.84, respectively (p = 0.07). The mean ROM ranges were 100.6 ± 17.54 and 101.3 ± 19.22, respectively (p = 0.09). But the mean operation time of the allograft and trabecular metal cone groups was 137 minutes (Range; 111–198) and 102minutes (Range; 93 −133) (p=0.02) respectively, which showed statistical significance. In follow-up x-rays, no migration or loosening of the implants, osteolysis and other complications were found in both groups. In follow-up 3D CT, osteointegration was seen at the trabecular metal cone site, host bone being interpreted to the host bone. The allograft group showed fibrous and stable union in follow-up 3D CT. Conclusion. According to this study, in case of revision TKA with large bone defect, using whether allograft or trabecular metal cones did not affect the clinical outcomes. However, operation time was significantly shorter in trabecular metal cone group, therefore, in patients with poor general condition along with severe underlying diseases, usage of trabecular metal cone would be a better choice to shorten operation time and ease postoperative care. Keywords. Revision TKA, metal cone, allograft, bone defect. For any figures or tables, please contact authors directly


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_12 | Pages 48 - 48
1 Oct 2018
Fillingham YA Darrith B Calkins T Abdel MP Malkani AL Schwarzkopf R Padgett DE Sershon RA Bini S Della Valle CJ
Full Access

Introduction. Tranexamic acid (TXA) is proven to reduce blood loss following total knee arthroplasty (TKA), but there are limited data on the impact of similar dosing regimens in revision TKA that is associated with greater blood loss. The purpose of this multi-center randomized trial was to determine the optimal regimen to maximize the blood-sparing properties of TXA in revision TKA. Methods. 233 Septic and aseptic revision TKA from six-centers were randomized to either receive 1g pre-incision intravenous (IV) TXA, 1g pre- and post-incision IV TXA, 1g pre-incision IV and 1g intra-operative topical TXA, or three doses of 1950mg oral TXA given 2 hours pre-operatively, 6 hours post-operatively, and the morning of postoperative day 1. Randomization was performed based on type of revision to ensure equivalent distribution among groups. The primary outcome was reduction in hemoglobin. Power analysis determined 40 patients per group were necessary to identify a 1g/dL difference with an alpha of 0.05 and beta of 0.80. Per-protocol analysis involved regression analysis and two one-sided t-tests for equivalence. Results. One patient withdrew, 3 didn't undergo surgery, 16 were screen failures, and 17 did not receive the assigned treatment, leaving 196 patients for the analysis. There was no significant difference in reduction in hemoglobin amongst treatment groups (2.88g/dL for oral TXA, 2.79g/dL for single-dose IV TXA, 2.59g/dL for combined IV/topical TXA, and 2.58g/dL for double-dose IV TXA; p=0.48). Similarly, calculated blood loss (p=0.63) and transfusions (p=0.78) were not significantly different between groups. Finally, equivalence testing assuming a 1g/dL difference in hemoglobin change as clinically relevant showed all possible pairings were statistically equivalent. Conclusions. Despite the higher risk of blood loss in revision TKA, all TXA regimens tested had equivalent blood-sparing properties. Surgeons should consider using the lowest effective dose and the least costly regimen for TXA use in revision TKA


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_2 | Pages 91 - 91
1 Feb 2020
Chun K Kwon H Kim K Chun C
Full Access

Purpose. The aim of this study was to assess the clinical and radiological result of the usage of chip bone graft in non-contained type bone defect in primary or revision total knee arthroplasty patients. Subjects and Methods. We investigated 32 patients who had underwent primary or revision total knee arthroplasty from March, 2014 to February, 2017 in our hospital, who had non-contained type of defect. The mean age was 73.1 years. 5 of them were males, while 27 of them were females. 7 of them were primary total knee arthroplasty patients, while 25 of them were revision patients. 8 of them had chip bone graft used both in the femur and tibia. 9 of them had chip bone graft used only in the tibia. The other 15 had chip bone graft used only in the femur. Wire-mesh was used in the 9 patients who had chip bone graft used only in the medial side of the tibia. We used KOOS (Knee injury and osteoarthritis outcome score), HSS (Hospital for Special Surgery knee service rating system) and WOMAC scores to assess the clinical result, before the surgery and at the last follow-up. In addition, we had follow-up x-rays and 3D CT done for the patients to check the mean bone union period. In addition, overall radiologic imaging studies were used for complications such as loosening, osteolysis and lesions with radiolucency. Result. The Mean follow-up period was 2.7 years (range; 2.1 to 5). The Mean preoperative KOOS was 102.8 (range; 47 to 132), while it became 31.8 postoperatively (range; 20 to 45). The mean HSS was 13.1 (range; 6 to 35), while it became 35.9 postoperatively (range; 24 to 64). The mean WOMAC was 82.9 (range; 62 to 92), while it became 22.5 postoperatively (range; 13 to 30). According to follow-up x-ray and CT, the mean bone union period was 10.6 months (range: 10 to 13). In follow-up 3D CT of all cases, we could check cortical healing and new bone formation, seen as medium to high-attenuating conglomerate. The graft-host junction showed trabecular ingrowth, while the medullary canal showed fibrous ingrowth. Radiologically, there was no complication such as loosening, osteolysis, migration and radiolucent lines around the stems or cement mantles. In addition, there was no complication such as infection. Conclusion. Chip bone graft is not a commonly used method for bone defect in total knee arthroplasty. According to the result of the usage of chip bone graft in primary or revision total knee arthroplasty with non-contained type of bone defect, it showed favorable result for the subject patients. Therefore, we can consider it as one of the effective methods to manage non-contained bone defect in knee arthroplasty. Keywords. Revision TKA, chip bone graft, wire-mesh, non-contained bone defect. For any figures or tables, please contact authors directly


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_1 | Pages 27 - 27
1 Jan 2016
Arora B Shah N
Full Access

Background. Subvastus approach for Total Knee Arthropalsty (TKA) allows a faster recovery. It is traditionally not utilized for revision surgeries because of difficulty in exposure of the knee and eversion of the patella. It is considered to have limited indications. We hypothesized that revision TKA should not really pose a problem as the exposure gained is adequate with added advantage of preserving the extensor mechanism, thereby allowing faster functional recovery. We present an analysis of the use of subvastus approach for revision TKAs. Materials and methods. 50 patients (50 knees) 37 females + 13 males with mean age 68 years underwent revision total knee arthroplasty (TKA) by subvastus approach between January 2006 to January 2013. All patients were prospectively evaluated by pre- and postoperative Knee Society and function score. The average follow-up was 24 months (range from 1 to 3 years) with minimum 1 year follow-up. The indications for revisions were aseptic loosening (20 knees), infection (12 knees), instability (12 knees) and peri-prosthetic fractures (6 knees). Constrained condylar prosthesis (43 knees), hinged prosthesis (6 knees) and custom made prosthesis (1 knee) were fixed using the subvastus approach. Infected knees underwent one or two staged revisions. Results. The approach provided adequate exposure in all revisions. The average Knee Society score improved from 42 to 83 and the function score from 48 to 65. The complications included medial collateral ligament injury (one case), patellar tendon avulsion (one case) and mal-tracking patella (one case). Average hospital stay was 4 days. Average blood lose was 400 ml. Conclusion. Our results compare favourably with other reported series on revision TKA. The subvastus approach can be considered for revision TKAs


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_9 | Pages 54 - 54
1 Oct 2020
Hernandez NM Hinton ZW Wu CJ Ryan SP Bolognesi† MP
Full Access

Introduction. Tibial cones are often utilized in revision total knee arthroplasty (TKA) with metaphyseal defects. However, there are few studies evaluating outcomes out to five years with a sufficient cohort. The purpose of this study was to evaluate implant survivorship and complications in revision TKAs with tibial cones. Methods. A retrospective review was completed from September 2006 through March 2018 evaluating 149 revision TKAs that received a tibial cone. The mean follow-up was 5.3 years. According to the AORI classification: 8% were 1, 18% were 2A, 55% were 2B, and 19% were 3. Results. Survival analysis at 6 years showed 96% free of revision for aseptic tibial loosening, 85% free of tibial component revision for any reason, and 72% free of reoperation. Eleven knees had progressive radiolucent lines with eight having tibial construct migration on serial radiographs. Aseptic tibial loosening was associated with significant tibial bone loss, AORI 3 (p=0.0001). Tibial component revision for any reason was associated with AORI 3 (p=0.013) and a pre-revision diagnosis of reimplantation after PJI (p<0.0001). Four knees had revision for aseptic tibial loosening, 12 knees had revision of the tibial construct for reasons other than aseptic loosening (11/12 were for PJI), and 15 knees had reoperation for reasons other than tibial construct revision. Conclusions. Revision TKA with tibial cones had excellent survivorship free of revision for tibial construct aseptic loosening, 96% at 6 years. Patients receiving a tibial cone construct at the time of reimplantation for PJI were at increased risk for tibial construct revision


The Bone & Joint Journal
Vol. 102-B, Issue 4 | Pages 458 - 462
1 Apr 2020
Limberg AK Tibbo ME Pagnano MW Perry KI Hanssen AD Abdel MP

Aims. Varus-valgus constrained (VVC) implants are often used during revision total knee arthroplasty (TKA) to gain coronal plane stability. However, the increased mechanical torque applied to the bone-cement interface theoretically increases the risk of aseptic loosening. We assessed mid-term survivorship, complications, and clinical outcomes of a fixed-bearing VVC device in revision TKAs. Methods. A total of 416 consecutive revision TKAs (398 patients) were performed at our institution using a single fixed-bearing VVC TKA from 2007 to 2015. Mean age was 64 years (33 to 88) with 50% male (199). Index revision TKA diagnoses were: instability (n = 122, 29%), aseptic loosening (n = 105, 25%), and prosthetic joint infection (PJI) (n = 97, 23%). All devices were cemented on the epiphyseal surfaces. Femoral stems were used in 97% (n = 402) of cases, tibial stems in 95% (n = 394) of cases; all were cemented. In total, 93% (n = 389) of cases required a stemmed femoral and tibial component. Femoral cones were used in 29%, and tibial cones in 40%. Survivorship was assessed via competing risk analysis; clinical outcomes were determined using Knee Society Scores (KSSs) and range of movement (ROM). Mean follow-up was four years (2 to 10). Results. The five-year cumulative incidence of subsequent revision for aseptic loosening and instability were 2% (95% confidence interval (CI) 0.2 to 3, number at risk = 154) and 4% (95% CI 2 to 6, number at risk = 153), respectively. The five-year cumulative incidence of any subsequent revision was 14% (95% CI 10 to 18, number at risk = 150). Reasons for subsequent revision included PJI (n = 23, of whom 12 had previous PJI), instability (n = 13), and aseptic loosening (n = 11). The use of this implant without stems was found to be a significant risk factor for subsequent revision (hazard ratio (HR) 7.58 (95% CI 3.98 to 16.03); p = 0.007). KSS improved from 46 preoperatively to 81 at latest follow-up (p < 0.001). ROM improved from 96° prerevision to 108° at latest follow-up (p = 0.016). Conclusion. The cumulative incidence of subsequent revision for aseptic loosening and instability was very low at five years with this fixed-bearing VVC implant in revision TKAs. Routine use of cemented and stemmed components with targeted use of metaphyseal cones likely contributed to this low rate of aseptic loosening. Cite this article: Bone Joint J 2020;102-B(4):458–462


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_10 | Pages 117 - 117
1 Jun 2018
Whiteside L
Full Access

Stems are a crucial part of implant stabilization in revision total knee arthroplasty. In most cases the metaphyseal bone is deficient, and stabilization in the diaphyseal cortical bone is necessary to keep the implant tightly fixed to bone and to prevent tilt and micromotion. While sleeves and cones can be effective in revision total joint arthroplasty, they are technically difficult and may lead to major bone loss in cases of loosening or infection, especially if the stem is cemented past the cone. A much more conservative method is to ream the diaphysis to the least depth possible to achieve tight circumferential fixation, and to apply porous augments to the undersurface of the tibial tray or inner surface of the femoral component to allow them to bottom out against the bone surface and apply compressive load. If a robust, strong taper, stem and component combination is used, rim contact on only one side is necessary to achieve rigid permanent fixation. Porous and non-porous stems are available. The non-porous stems should have a spline surface that engages the diaphyseal bone and achieves rigid initial fixation but does not provide long-term axillary support. In that way the porous rim-engaging surface can bear compressive load and finally unload the stem and taper junction. Correctly designed stems do not stress relieve unless they are porous-coated. In situations where metaphyseal bone is not available, porous-coated stems that link to hinge prostheses are a very important part of the armamentarium in complex revision arthroplasty. Use of stems requires experience and special technique. Slight underreaming and initial scratch fit are necessary techniques. This does not result in tight fixation every time because split of the cortex does occasionally occur. In most cases these splits do not need to be repaired, but when there is a question, an intra-operative x ray should be taken and the surgeon should be prepared to repair the fracture. Stems are an essential part of revision total knee arthroplasty. A tightly fit stem in the diaphysis is necessary for fixation when metaphyseal bone is deficient. No amount of cement pressed into the deficient metaphyseal bone will substitute for rigid stem fixation


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_11 | Pages 72 - 72
1 Oct 2019
Hevesi M Wyles CC Yao JJ Maradit-Kremers H Habermann EB Bews KA Ransom JE Lewallen DG Berry DJ
Full Access

Introduction. Revision total knee arthroplasty (revision TKA) occurs for a wide variety of indications and along with revision total hip arthroplasty is billed for using Diagnosis-Related Groups (DRGs) 466, 467, and 468 in the United States. However, DRGs do not account for revision etiology, a potentially substantial driver of cost. This study investigates revision TKA costs and 30-day complications by indication, employing both local granular as well as national standardized databases. Methods. Hospitalization costs and complication rates for 1,422 aseptic revision TKAs performed at a high-volume center between 2009 and 2015 were retrospectively reviewed. Additionally, charges for 28,173 revision TKAs in the National Inpatient Sample (NIS) were converted to costs using the Healthcare Cost and Utilization Project cost-to-charge ratios. 30-day complication rates for 3,450 revision TKAs were obtained using the American College of Surgeons National Surgical Quality Improvement Project (ACS-NSQIP). Costs and complications were compared between revision TKAs performed for the indication of fracture, wear/loosening, and instability with use of simultaneous and pairwise comparisons and a multivariable model accounting for American Society of Anesthesiologists (ASA) score, age, and sex. Results. Local hospitalization costs for fracture (median, $30,643) were significantly higher than those for wear/loosening ($24,734; p < 0.001) or instability ($22,932; p < 0.001), with differences remaining significant even after adjusting for patient comorbidities (p < 0.001). Local fracture patients were admitted for an average of 1.9 days longer (mean length of stay [LOS]: 4.8 days; IQR: 3 – 6) than instability patients (mean LOS: 2.9; IQR: 2 – 3; p < 0.001) and 1.7 days longer than wear/loosening patients (mean LOS: 3.1, IQR: 2 – 3; p < 0.001) but had similar 30-day orthopedic-specific complication rates (10.8%) as compared to instability (11.2%; p > 0.999) and wear/loosening (15.9%; p = 0.333). Nationally, NIS costs for fracture (median, $31,207) were higher than those for other aseptic indications (wear/loosening: $21,747; instability: $16,456; p< 0.001). Combined medical and surgical complication rates for fracture (56.6% of patients with ≥1 complication) were significantly higher than those for wear/loosening (19.7%) and instability (15.5%) (p < 0.001), with 3.5 – 5.4 fold increased transfusion rates (45.7% fracture, 13.2% wear/loosening, 8.5% instability; p < 0.001) and 1.2 – 3.3 fold increased urinary tract infection rates (2.3% fracture, 0.7% wear/loosening, 1.9% instability; p = 0.004). Discussion and Conclusion. Hospitalization costs for revision TKA for fracture were 37% to 50% higher than for all other aseptic revision TKAs, both locally and nationally. This increased cost persisted even after multivariable comorbidity adjustment, the current approach for DRG assignment for both revision TKA and THA reimbursement. Indication-specific coding and reimbursement systems are necessary to maintain sustainable access to revision TKA for all patients. For figures, tables, or references, please contact authors directly


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 136 - 136
1 Mar 2010
Cho W Yeom Y Woo J
Full Access

We analyzed the causes of 113 revision total knee arthroplasties in 84 patients between December 1996 and June 2008. Patient history, medical record and radiographs were reviewed to detect the main cause of failure of primary total knee arthroplasty. The causes of revision total knee arthroplasty were as follows: 44 infections (38.9 %), 34 loosenings (30.1%), 22 polyethylene wears or breakages (19.5%), 5 stiffness (4.4%), 4 polyethylene dislocations (3.5%), 2 patellar dislocations (1.8%), 1 patellar component failure and 1 instability (0.9%, each). The mean interval from the index operation to the revision surgery was 59 months (1 month-20 years). Infection was the most common causes of revision TKA and followed by loosening, wear or breakage of polyethylene, stiff knee, dislocation of polyethylene and so on


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 107 - 107
1 Apr 2019
Henderson A Croll V Szalkowski A Szmyd G Bischoff J
Full Access

Introduction. Removal of primary components during revision TKA procedure can damage underlying bone, resulting in defects that may need filled for stability of the revision reconstruction. Special revision components including cones and/or augments are often used to compensate for the missing bones. Little work has been done to characterize metaphyseal geometry in the vicinity of the knee joint, however, in order to motivate proper size and shape of cones and augments. The objective of this study was to use statistical shape modelling to evaluate variation in endosteal anatomy for revision TKA. Methods. Digital models of the femur and tibia were generated through segmentation of computed tomography scans, for the femur and the tibia (n∼500). Custom software was used to perform virtual surgery and statistical shape analysis of the metaphyseal geometry. A representative and appropriately sized revision femoral component was placed on each bone, assuming anterior referencing with an external rotation of 3 degrees from the posterior condyle axis. The outer and inner boundaries of the cortical bone were determined at the resection level and at 5 mm increments proximally, up to 40 mm. Similar analyses were performed on the tibia, using a typical revision resection (0 degrees medial and posterior slope), with outer and inner boundaries of the cortical bone were determined in 5 mm increments up to 40mm distal to the resection. Metaphyseal contours were exported relative to the central fixation feature of the implant, and average geometries were calculated based on size, and across the entire cohort. Principal Component Analysis (PCA) was used to quantify the variability in shape, specifically to evaluate the +/− 1 and 2 standard deviation geometries at each cross section level of Principal Component 1 (PC1). Results. Representative results illustrating the effect of size for the femur at single depth and the effect of depth and PC1 for tibia are reported. The average inner metaphyseal geometry of the femur (30mm proximal to resection) varied from 25.1×47.7 mm (AP x ML) at the smallest size to 54.5×78.0 at the largest size. The overall average tibia geometry decreased from 51.5×69.5 mm at the base resection level to 33.5×31.3 mm at the most distal resection level (40mm) distal to the resection. At the 20 mm level, the average tibia contour of 45.0×47.8 mm changed to 32.2×33.4 at −2 standard deviations of PC1 and 57.9×62.4 mm at the +2 standard deviations of PC1. Discussion. The generated contours can be used as a design input to optimize the shape of cones and augments, in order to fit potential defects in the femur and tibia encountered during revision TKA while respecting the anatomical constraints of the bone. Statistical shape analysis shows that these constraints are not strictly uniform scaling, based on bone size or on location in the metaphysis, but rather reflect variations in shape that may be used to optimize fit and stability of the prostheses


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 127 - 127
1 Mar 2009
von Knoch F Zanetti M Naal F Preiss S Hodler J von Knoch M Munzinger U Drobny T
Full Access

Introduction: Stiffness after primary total knee arthroplasty (TKA) is a severe complication that has been associated with excessive internal rotation of the femoral component. Methods: Between 2001 and 2004, 18 patients with 18 well-fixed, aseptic primary TKA underwent revision TKA at a single high-volume joint replacement center for stiffness in the presence of femoral component mal-rotation. Stiffness was defined as ROM with less than 90° of maximum flexion or a flexion contracture greater than 10°. Femoral component malrotation was defined as a condylar twist angle of more than 4° of internal rotation using CT scans. Following IRB approval, 17 out of 18 patients (median age at time of the index surgery 62.7 years, range 45 to 78; female, n=11; male, n=6) were available for retrospective outcome assessment. The mean time between primary and revision TKA was 3.2 years (range, 9–79 months). At a mean follow-up of 3.3 years (range, 2 to 6), all patients were evaluated clinically using the Knee Society objective and functional scores, and by CT measurement of femoral component rotation. Patients without additional procedures between primary and index revision TKA (group A, n=9) were compared using Student t-testing with those which had undergone additional interventions (group B, n=8). Results: Five patients had required additional procedures after the index revision TKA including closed manipulation under anesthesia in one case, patellar resurfacing in one case, metal removal after tubercle osteotomy and open debridement in another case, and tibial component revision followed by revision TKA in one case. CT scans after revision TKA revealed correction of femoral component rotation in all but one case from each group. After revision TKA, the mean objective score was overall 73 points, in group A 82 points compared to 63 points in group B (p< 0.001). In group A there were 78% excellent or good results compared to 13% in group B. The mean function score was overall 74 points, 78 points in group A compared to 69 points in group B. There were 67% good or excellent results in group A compared to 12% in group B. Mean flex-ion increased overall from 71 to 92 degrees (p< 0.01), in group A from 61 to 96 degrees (p< 0.01) and in group B from 82 to 89 degrees. Mean flexion contracture was reduced overall from 7 to 4 degrees, in group A from 6 to 3 degrees, and in group B from 8 to 5 degrees. Stiffness persisted in four cases (24%) (group A, n=1; group B, n=3). Satisfaction (VAS 0–100; 100=completely satis-fied) scored overall a mean of 52 points, in group A 57 points and in group B 44 points. Conclusion: Overall, revision TKA for knee stiffness associated with femoral component internal malrotation resulted in significantly improved knee motion. However, outcome was less predictable in those patients with additional procedures between primary and revision TKA


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 7 | Pages 879 - 884
1 Jul 2008
Porteous AJ Hassaballa MA Newman JH

We identified 148 patients who had undergone a revision total knee replacement using a single implant system between 1990 and 2000. Of these 18 patients had died, six had developed a peri-prosthetic fracture and ten had incomplete records or radiographs. This left 114 with prospectively-collected radiographs and Bristol knee scores available for study. The height of the joint line before and after revision total knee replacement was measured and classified as either restored to within 5 mm of the pre-operative height or elevated if it was positioned more than 5 mm above the pre-operative height. The joint line was elevated in 41 knees (36%) and restored in 73 (64%). Revision surgery significantly improved the mean Bristol knee score from 41.1 (. sd. 15.9) pre-operatively to 80.5 (. sd. 15) post-operatively (p < 0.001). At one year post-operatively both the total Bristol knee score and its functional component were significantly better in the restored group than in the elevated group (p < 0.01). Overall, revision from a unicondylar knee replacement required less use of bone graft, fewer component augments, restored the joint line more often and gave a significantly better total Bristol knee score (p < 0.02) and functional score (p < 0.01) than revision from total knee replacement. Our findings show that restoration of the joint line at revision total knee replacement gives a significantly better result than leaving it unrestored by more than 5 mm. We recommend the greater use of distal femoral augments to help to achieve this goal


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_15 | Pages 68 - 68
1 Aug 2017
Lewallen D
Full Access

The amount of bone loss due to implant failure, loosening, or osteolysis can vary greatly and can have a major impact on reconstructive options during revision total knee arthroplasty (TKA). Massive bone loss can threaten ligamentous attachments in the vicinity of the knee and may require use of components with additional constraint to compensate for associated ligamentous instability. Classification of bone defects can be helpful in predicting the complexity of the reconstruction required and in facilitating pre-operative planning and implant selection. One very helpful classification of bone loss associated with TKA is the Anderson Orthopaedic Research Institute (AORI) Bone Defect Classification System as it provides the means to compare the location and extent of femoral and tibial bone loss encountered during revision surgery. In general, the higher grade defects (Type IIb or III) on both the femoral and tibial sides are more likely to require stemmed components, and may require the use of either structural graft or large augments to restore support for currently available modular revision components. Custom prostheses were previously utilised for massive defects of this sort, but more recently have been supplanted by revision TKA component systems with or without special metal augments or structural allograft. Options for bone defect management are: 1) Fill with cement; 2) Fill with cement supplemented by screws or K-wires; 3) Morselised bone grafting (for smaller, especially contained cavitary defects); 4) Small segment structural bone graft; 5) Impaction grafting; 6) Large prosthetic augments (cones); 7) Massive structural allograft-prosthetic composites (APC); 8) Custom implants. Maximizing support on intact host bone is a fundamental principle to successful reconstruction and frequently requires extending fixation to the adjacent diaphysis. Pre-operative planning is facilitated by good quality radiographs, supplemented on occasion by additional imaging such as CT. Fluoroscopically controlled x-ray views may assist in diagnosing the loose implant by better revealing the interface between the implant and bone and can facilitate accurate delineation of the extent of bone deficiency present. Part of the pre-operative plan is to ensure adequate range and variety of implant choices and bone graft resources for the planned reconstruction allowing for the potential for unexpected intra-operative findings such as occult fracture through deficient periprosthetic bone. Reconstruction of bone deficiency following removal of the failed implant is largely dictated by the location and extent of bone loss and the quality of bone that remains. While massive bone loss may compromise ligamentous attachment to bone, in the majority of reconstructions the degree of implant constraint needed for proper balancing and restoration of stability is independent of the bone defect. Thus some knees with minimal bone deficiency may require increased constraint due to the status of the soft tissues while others involving very large bone defects especially of the cavitary sort may be well managed with minimal constraint. Highly porous metal augments designed to reestablish metaphyseal support and function in the manner of a prosthetic structural graft have been introduced or are under development by several manufacturers. Published reports of short term experiences have been encouraging for both the tibial side and for femoral augmentation. It remains to be seen whether these implants will provide the desired longer term durability