Advertisement for orthosearch.org.uk
Results 1 - 50 of 516
Results per page:
Bone & Joint Open
Vol. 2, Issue 8 | Pages 611 - 617
10 Aug 2021
Kubik JF Bornes TD Klinger CE Dyke JP Helfet DL

Aims. Surgical treatment of young femoral neck fractures often requires an open approach to achieve an anatomical reduction. The application of a calcar plate has recently been described to aid in femoral neck fracture reduction and to augment fixation. However, application of a plate may potentially compromise the regional vascularity of the femoral head and neck. The purpose of this study was to investigate the effect of calcar femoral neck plating on the vascularity of the femoral head and neck. Methods. A Hueter approach and capsulotomy were performed bilaterally in six cadaveric hips. In the experimental group, a one-third tubular plate was secured to the inferomedial femoral neck at 6:00 on the clockface. The contralateral hip served as a control with surgical approach and capsulotomy without fixation. Pre- and post-contrast MRI was then performed to quantify signal intensity in the femoral head and neck. Qualitative assessment of the terminal arterial branches to the femoral head, specifically the inferior retinacular artery (IRA), was also performed. Results. Quantitative MRI revealed a mean reduction of 1.8% (SD 3.1%) of arterial contribution in the femoral head and a mean reduction of 7.1% (SD 10.6%) in the femoral neck in the plating group compared to non-plated controls. Based on femoral head quadrant analysis, the largest mean decrease in arterial contribution was in the inferomedial quadrant (4.0%, SD 6.6%). No significant differences were found between control and experimental hips for any femoral neck or femoral head regions. The inferior retinaculum of Weitbrecht (containing the IRA) was directly visualized in six of 12 specimens. Qualitative MRI assessment confirmed IRA integrity in all specimens. Conclusion. Calcar femoral neck plating at the 6:00 position on the clockface resulted in minimal decrease in femoral head and neck vascularity, and therefore it may be considered as an adjunct to laterally-based fixation for reduction and fixation of femoral neck fractures, especially in younger patients. Cite this article: Bone Jt Open 2021;2(8):611–617


The Bone & Joint Journal
Vol. 102-B, Issue 12 | Pages 1629 - 1635
1 Dec 2020
Wang Q Sheng N Rui B Chen Y

Aims. The aim of this study was to explore why some calcar screws are malpositioned when a proximal humeral fracture is treated by internal fixation with a locking plate, and to identify risk factors for this phenomenon. Some suggestions can be made of ways to avoid this error. Methods. We retrospectively identified all proximal humeral fractures treated in our institution between October 2016 and October 2018 using the hospital information system. The patients’ medical and radiological data were collected, and we divided potential risk factors into two groups: preoperative factors and intraoperative factors. Preoperative factors included age, sex, height, weight, body mass index, proximal humeral bone mineral density, type of fracture, the condition of the medial hinge, and medial metaphyseal head extension. Intraoperative factors included the grade of surgeon, neck-shaft angle after reduction, humeral head height, restoration of medial support, and quality of reduction. Adjusted binary logistic regression and multivariate logistic regression models were used to identify pre- and intraoperative risk factors. Area under the curve (AUC) analysis was used to evaluate the discriminative ability of the multivariable model. Results. Data from 203 patients (63 males and 140 females) with a mean age of 62 years (22 to 89) were analyzed. In 49 fractures, the calcar screw was considered to be malpositioned; in 154 it was in the optimal position. The rate of malpositioning was therefore 24% (49/203). No preoperative risk factor was found for malpositioning of the calcar screws. Only the neck-shaft angle was found to be related to the risk of screw malpositioning in a multivariate model (with an AUC of 0.72). For the fractures in which the neck-shaft angle was reduced to between 130° and 150°, 91% (133/46) of calcar screws were in the optimal position. Conclusion. The neck-shaft angle is the key factor for the appropriate positioning of calcar screws when treating a proximal humeral fracture with a locking plate. We recommend reducing the angle to between 130° and 150°. Cite this article: Bone Joint J 2020;102-B(12):1629–1635


Bone & Joint Open
Vol. 5, Issue 2 | Pages 123 - 131
12 Feb 2024
Chen B Duckworth AD Farrow L Xu YJ Clement ND

Aims. This study aimed to determine whether lateral femoral wall thickness (LWT) < 20.5 mm was associated with increased revision risk of intertrochanteric fracture (ITF) of the hip following sliding hip screw (SHS) fixation when the medial calcar was intact. Additionally, the study assessed the association between LWT and patient mortality. Methods. This retrospective study included ITF patients aged 50 years and over treated with SHS fixation between 2019 and 2021 at a major trauma centre. Demographic information, fracture type, delirium status, American Society of Anesthesiologists grade, and length of stay were collected. LWT and tip apex distance were measured. Revision surgery and mortality were recorded at a mean follow-up of 19.5 months (1.6 to 48). Cox regression was performed to evaluate independent risk factors associated with revision surgery and mortality. Results. The cohort consisted of 890 patients with a mean age of 82 years (SD 10.2). Mean LWT was 27.0 mm (SD 8.6), and there were 213 patients (23.9%) with LWT < 20.5 mm. Overall, 20 patients (2.2%) underwent a revision surgery following SHS fixation. Adjusting for covariates, LWT < 20.5 mm was not independently associated with an increased revision or mortality risk. However, factors that were significantly more prevalent in LWT < 20.5 mm group, which included residence in care home (hazard ratio (HR) 1.84; p < 0.001) or hospital (HR 1.65; p = 0.005), and delirium (HR 1.32; p = 0.026), were independently associated with an increased mortality risk. The only independent factor associated with increased risk of revision was older age (HR 1.07; p = 0.030). Conclusion. LWT was not associated with risk of revision surgery in patients with an ITF fixed with a SHS when the calcar was intact, after adjusting for the independent effect of age. Although LWT < 20.5 mm was not an independent risk factor for mortality, patients with LWT < 20.5 mm were more likely to be from care home or hospital and have delirium on admission, which were associated with a higher mortality rate. Cite this article: Bone Jt Open 2024;5(2):123–131


The Bone & Joint Journal
Vol. 101-B, Issue 7 | Pages 779 - 786
1 Jul 2019
Lamb JN Baetz J Messer-Hannemann P Adekanmbi I van Duren BH Redmond A West RM Morlock MM Pandit HG

Aims. The aim of this study was to estimate the 90-day risk of revision for periprosthetic femoral fracture associated with design features of cementless femoral stems, and to investigate the effect of a collar on this risk using a biomechanical in vitro model. Materials and Methods. A total of 337 647 primary total hip arthroplasties (THAs) from the United Kingdom National Joint Registry (NJR) were included in a multivariable survival and regression analysis to identify the adjusted hazard of revision for periprosthetic fracture following primary THA using a cementless stem. The effect of a collar in cementless THA on this risk was evaluated in an in vitro model using paired fresh frozen cadaveric femora. Results. The prevalence of early revision for periprosthetic fracture was 0.34% (1180/337 647) and 44.0% (520/1180) occurred within 90 days of surgery. Implant risk factors included: collarless stem, non-grit-blasted finish, and triple-tapered design. In the in vitro model, a medial calcar collar consistently improved the stability and resistance to fracture. Conclusion. Analysis of features of stem design in registry data is a useful method of identifying implant characteristics that affect the risk of early periprosthetic fracture around a cementless femoral stem. A collar on the calcar reduced the risk of an early periprosthetic fracture and this was confirmed by biomechanical testing. This approach may be useful in the analysis of other uncommon modes of failure after THA. Cite this article: Bone Joint J 2019;101-B:779–786


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_2 | Pages 41 - 41
1 Mar 2021
Lamb J Coltart O Adekanmbi I Stewart T Pandit H
Full Access

Abstract. Objective. To estimate the effect of calcar collar separation on the likelihood of calcar collar contact during in vitro periprosthetic fracture. Methods. Three groups of six composite femurs were implanted with a collared cementless femoral stem. Neck resection was increased between groups (group 1 = normal, group 2 = 3mm additional, group 3 = 6mm additional), to simulate failure to obtain calcar collar contact. Prior to each trial, the distances between anterior (ACC) and posterior (PCC) collar and the calcar were measured. Periprosthetic fractures of the femur were simulated using a previously published technique. High speed video recording identified when collar to calcar contact (CCC) occurred. The ACC and PCC were compared between trials where the CCC was and was not achieved. Regression estimated the odds of failing to achieve CCC for a given ACC or PCC. Results. CCC was achieved prior to fracture in all cases in group one, 50% in group two and 0% in group three. The median (range) ACC for those trials where CCC was achieved was 0.40 (0.00, 3.37) mm versus 6.15 (3.06 to 6.88) mm, where CCC was not achieved (p <0.01). The median (range) PCC for those trials where CCC was achieved was 0.85 (0.00 to 3.71) mm versus 5.97 (2.23 to 7.46) mm, where CCC was not achieved (p <0.01). Binomial logistic regression estimated risk of failure to obtain CCC increased 3.8 fold (95% confidence interval 1.6 to 30.2, p <0.05) for each millimetre of PCC. Conclusions. Increased separation between collar and calcar reduced the likelihood of calcar collar contact during a simulated periprosthetic fracture of the femur. Surgeons should aim to achieve a calcar-collar distance of less than 1mm following implantation to ensure calcar collar contact during periprosthetic femoral fracture and to reduce the risk of fracture. Declaration of Interest. (a) fully declare any financial or other potential conflict of interest


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 6 | Pages 842 - 845
1 Aug 2000
Wroblewski BM Siney PD Fleming PA Bobak P

The calcar femorale is a vertical plate of bone lying deep to the lesser trochanter and is formed as a result of traction of the iliopsoas which separates the femoral cortex into two distinct layers, the calcar femorale and the medial femoral cortex. They fuse together proximally to form the medial femoral neck. A stem placed centrally will abut against the calcar femorale with little or no space for cement. Clearing of the calcar will offer space for a cement layer, which will support the stem proximally on the posterior aspect. We compared two consecutive groups of Charnley low-friction arthroplasties, with and without clearing of the calcar. In 330 patients who had an arthroplasty without clearing the calcar, there were ten revisions for aseptic loosening of the stem and six other stems were considered ‘definitely loose’, giving a rate of failure of 4.8%. In 111 patients in whom the calcar was cleared there was only one revision for aseptic loosening and no stems were classed as ‘definitely loose’, giving a rate of failure of 0.9%. Survivorship analysis has again shown the need for long-term follow-up; the differences became clear after ten years but because of the relatively small numbers, statistical analysis is not yet applicable. We now clear the calcar femorale routinely and advocate optimal access to the medullary canal and insertion of the stem in the area of the piriform fossa


The Bone & Joint Journal
Vol. 106-B, Issue 3 Supple A | Pages 121 - 129
1 Mar 2024
Orce Rodríguez A Smith PN Johnson P O'Sullivan M Holder C Shimmin A

Aims. In recent years, the use of a collared cementless femoral prosthesis has risen in popularity. The design intention of collared components is to transfer some load to the resected femoral calcar and prevent implant subsidence within the cancellous bone of the metaphysis. Conversely, the load transfer for a cemented femoral prosthesis depends on the cement-component and cement-bone interface interaction. The aim of our study was to compare the three most commonly used collared cementless components and the three most commonly used tapered polished cemented components in patients aged ≥ 75 years who have undergone a primary total hip arthroplasty (THA) for osteoarthritis (OA). Methods. Data from the Australian Orthopaedic Association National Joint Replacement Registry from 1 September 1999 to 31 December 2022 were analyzed. Collared cementless femoral components and cemented components were identified, and the three most commonly used components in each group were analyzed. We identified a total of 11,278 collared cementless components and 47,835 cemented components. Hazard ratios (HRs) from Cox proportional hazards models, adjusting for age and sex, were obtained to compare the revision rates between the groups. Results. From six months postoperatively onwards, patients aged ≥ 75 years undergoing primary THA with primary diagnosis of OA have a lower risk of all-cause revision with collared cementless components than with a polished tapered cemented component (HR 0.78 (95% confidence interval 0.64 to 0.96); p = 0.018). There is no difference in revision rate prior to six months. Conclusion. Patients aged ≥ 75 years with a primary diagnosis of OA have a significantly lower rate of revision with the most common collared cementless femoral component, compared with the most common polished tapered cemented components from six months postoperatively onwards. The lower revision rate is largely due to a reduction in revisions for fracture and infection. Cite this article: Bone Joint J 2024;106-B(3 Supple A):121–129


Bone & Joint Research
Vol. 9, Issue 9 | Pages 534 - 542
1 Sep 2020
Varga P Inzana JA Fletcher JWA Hofmann-Fliri L Runer A Südkamp NP Windolf M

Aims. Fixation of osteoporotic proximal humerus fractures remains challenging even with state-of-the-art locking plates. Despite the demonstrated biomechanical benefit of screw tip augmentation with bone cement, the clinical findings have remained unclear, potentially as the optimal augmentation combinations are unknown. The aim of this study was to systematically evaluate the biomechanical benefits of the augmentation options in a humeral locking plate using finite element analysis (FEA). Methods. A total of 64 cement augmentation configurations were analyzed using six screws of a locking plate to virtually fix unstable three-part fractures in 24 low-density proximal humerus models under three physiological loading cases (4,608 simulations). The biomechanical benefit of augmentation was evaluated through an established FEA methodology using the average peri-screw bone strain as a validated predictor of cyclic cut-out failure. Results. The biomechanical benefit was already significant with a single cemented screw and increased with the number of augmented screws, but the configuration was highly influential. The best two-screw (mean 23%, SD 3% reduction) and the worst four-screw (mean 22%, SD 5%) combinations performed similarly. The largest benefits were achieved with augmenting screws purchasing into the calcar and having posteriorly located tips. Local bone mineral density was not directly related to the improvement. Conclusion. The number and configuration of cemented screws strongly determined how augmentation can alleviate the predicted risk of cut-out failure. Screws purchasing in the calcar and posterior humeral head regions may be prioritized. Although requiring clinical corroborations, these findings may explain the controversial results of previous clinical studies not controlling the choices of screw augmentation


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 108 - 108
1 Mar 2010
Williams D Petruccelli D de Beer J
Full Access

Total hip arthroplasty (THA) allows patients to return to an active lifestyle. Unfortunately one of the more common complications of cementless THA is a fracture of the greater trochanter (GT) or the calcar. These may compromise the outcomes of THA, but there are no large studies looking into this hypothesis. Between September 1998 and August 2005 the Hamilton Arthroplasty group performed 2282 THA operations. Demographic and outcome data on these patients was collected and tabulated in a prospective database. Radiographs were available on a picture archiving system for 1075 of the patients, 85% of which were primary THAs. GT and calcar fractures were identified. Statistical comparisons on the normal distributed outcome data were made using the Student’s T-test comparing repaired and missed fractures. A total of 60 GT fractures were found in the review of 1075 radiographs, giving an incidence of 5.6%. This included 19 isolated GT fractures and 10 GT fractures with associated calcar fractures that were found in primary hip arthroplasties, 48% of the total. Revision hip surgeries had 14 isolated GT fractures and 17 GT fractures with associated calcar fracture. We found that 23 (40%) of all GT fractures were missed intra-operatively and did not receive any fixation. All calcar fractures were noted and repaired, even if the associated GT fracture was not. 106 isolated calcar fractures were noted, 10% of all arthroplasties, only one of which did not receive fixation. Of this, 85 (80%) were from primary total hip arthroplasty and 21 (20%) from revision hip arthroplasty. Evaluation of the outcome data showed no significant difference between repaired and missed GT fractures. Reported outcomes compared favourably with the average for all THA in that time period. Adoption of cementless total hip arthroplasty in North America undoubtedly increases the rate of GT and calcar fractures. Most calcar fractures were noted and fixed but only 50% of GT fractures were discovered intraoperatively, an area of potential improvement. Greater trochanter and recognized calcar fractures may not have long-term detrimental effects


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 83 - 83
1 Mar 2013
Iwase T Kouyama A Matsushita N
Full Access

Introduction. Segmental defects of the femur present a major problem during revision hip arthroplasty. In particular, calcar segmental defects may compromise initial and long-tem femoral stem stability. Objective. The objective of the present study is to assess mid-term clinical and radiographic follow-up results at least two years after femoral revision comprising reconstruction for calcar segmental defect using metal wire mesh and impacted morcellised allograft. Methods. We performed 26 femoral revisions with calcar reconstruction in 24 patients between 2002 and 2010. The average age was 69.7 years, and the average follow-up period was 5 years and 1 month. All surgeries were performed using a cemented polished collarless tapered stem. The segmental calcar defect was reconstructed with metal wire mesh with doubled stainless wires. Large sized morcellised cancellous allograft was tightly impacted into the cavity between the phantom stem and the metal wire mesh. Nineteen hips were reconstructed with impaction bone grafting of the femur, and 7 hips with cement-in-cement technique except for the reconstructed calcar region.ã�� For clinical assessment, Merle d'Aubigné and Postel hip scores were recorded. For radiological assessment, antero-posterior hip radiographs were analyzed pre-operatively, and post-operatively at one month, 6 months and every 6 months thereafter. Clear lines around the femoral component using Gruen zone classification, stem subsidence in cement mantle, and change of stem axis were recorded. Kaplan-Meier survival analyses were performed with any re-operation of the femoral component or aseptic loosening as end points. In one case, the histological appearance of a biopsy specimen of the most proximal part of the reconstructed calcar, which was obtained at a later surgery for infection at 4 years after the revision, is described. Results. For clinical assessment, the mean Merle d'Aubigné and Postel hip scores improved from 10.4 points before the operation to 14.7 points at the final follow-up. For radiological assessment, no clear lines at the cement-bone interface and no stem axis changes were detected. Twenty-five of 26 hips showed less than 2 mm of stem subsidence at the final follow-up and one hip showed 2.2 mm stem subsidence. Both hips of one female patient underwent a one stage stem exchange because of an infection that occurred 48 months after revision. No cases showed aseptic loosening up to and including the last follow-up. The Kaplan-Meier survival analysis revealed that the survival rate at five years after revision was 88.0% with any type of re-operation on the femoral side as the endpoint and 100% with aseptic stem loosening as the endpoint, respectively. A biopsy specimen taken from the most proximal part of the reconstructed calcar region at 4 years after surgery in the infected case showed almost complete regeneration of viable bone with normal marrow spaces with partially formed granulation tissue. Conclusion. Reconstruction using metal wire mesh and tightly impacted morcellised allograft is a favorable method for the correction a calcar segmental defect. The procedure is simple and reliable, achieving initial and mid-term stem stability even for femurs with a complete calcar defect


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVI | Pages 53 - 53
1 Aug 2012
Mayhew P Vindlacheruvu M Poole K
Full Access

The calcar femorale or ‘true neck’ of the femur has a role in transmitting load from the cantilevered neck to the femoral shaft (Zhang 2009). It can appear as a distinct condensation in clinical CT images because its structure is very similar to compact bone (Aspden 1998). Harty (1957) proposed that the calcar acts as a ‘spike’ in certain fall situations, contributing to splitting of the trochanter. We hypothesised that among elderly fallers, the size of the calcar would influence whether fractures occurred in the trochanteric (TR) or femoral neck (FN) site. We also asked whether patients who sustained a fracture had more or less calcar bone than frailty-matched controls that fell but didn't fracture. The FEMCO study is designed to investigate male (M) and female (F) patients with acute hip fracture with multi-detector CT, before they undergo surgery. It includes an age, sex and frailty-matched control group (who have sustained at least one injurious fall without hip fracture). The fractured hip is reconstructed in 3D for classification of fracture type (FN or TR). For the present pilot study, there were 14 cases (5TR, 9FN mean 80+/−8.5yrs. 7M, 7F) and 11 controls (83+/−7.0yrs. 3M, 8F). Axial CT slices where a calcar was visible were opened in Stradwin 4.1 software (Treece 2011). The calcar femorale was semi-automatically selected with the flood fill tool. Each axial image that contained a visible calcar was included in the analysis, so that for each femur a single calcar volume was generated. Results were examined using ANOVA. Combining male and female results, there was a non-significant trend towards a higher calcar volume in patients sustaining trochanteric rather than femoral neck fractures (0.73cm3 +/− 0.26 vs 0.61cm3 +/−0.14, p=0.27) but no difference between cases and controls. Males had a significantly higher calcar volume than females (mean 0.82cm3 +/− 0.24 vs 0.59cm3 +/− 0.13, p=0.005). Further studies are now planned in larger samples of each sex, to examine the role of the calcar in fracture mechanics. Three-dimensional visualisations provide a novel insight into the damage patterns and resultant fragment locations


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_6 | Pages 30 - 30
1 May 2019
Lamb J Baetz J Messer-Hannemann P Redmond A West R Morlock M Pandit H
Full Access

Background. Post-operative periprosthetic femoral fractures (PFF) are a devastating complication associated with high mortality and are costly. Few risk factors are modifiable apart from implant choice. The design features governing risk of PFF are unknown. We estimated the 90-day risk of revision for PFF associated with design features of cementless femoral stems and to investigate the effect of a collar on early PFF risk using a biomechanical in-vitro model. Patients, materials and methods. 337 647 primary THAs from the National Joint Registry (UK) were included in a multivariable survival and regression analysis to identify the adjusted hazard of PFF revision following primary THA using cementless stems. The effect of a collar in cementless THA on early PFF was evaluated in an in-vitro model using paired fresh frozen cadaveric femora. Results. Prevalence of PFF revision was 0.34% (1180/337647) and 44.0% occurred (520/1180) within 90 days of surgery. Implant risk factors included: collarless stem, non grit-blasted finish and triple tapered design. In the in-vitro PFF model a medial calcar collar consistently improved construct stability and fracture resistance. Discussion. During rotational injury the collar can load the calcar in compression increasing the force required for a fracture. This increases the force required to cause a PFF around a collared implant versus collarless implants. The calcar possibly acts as a check-rein which prevents excessive peri-prosthetic trabecular deformation in rotational injuries and may improve the resistance to loosening after high energy injuries which do not cause cortical fracture. Conclusion. Analysis of stem design features in registry data is a useful method to identify implant characteristics which affect the risk of early PFF around cementless femoral stems. Calcar collar reduced early PFF risk and this was confirmed by biomechanical testing. This approach may be useful in the analysis of other uncommon arthroplasty failure modes


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 2 | Pages 228 - 231
1 Feb 2008
Buttaro M Araujo GS Araujo ES Comba F Piccaluga F

Metal meshes are used in revision surgery of the hip to contain impacted bone grafts in cases with cortical or calcar defects in order to provide rotational stability to the stem. However, the viability of bone allografts under these metal meshes has been uncertain. We describe the histological appearances of biopsies obtained from impacted bone allografts to the calcar contained by a metal mesh in two femoral reconstructions which needed further surgery at 24 and 33 months after the revision procedure. A line of osteoid and viable new bone was observed on the surface of necrotic trabeculae. Active bone marrow between these trabeculae showed necrotic areas in some medullary spaces with reparative fibrous tissue and isolated reactive lymphocytes. This is interpreted as reparative changes after revascularisation of the cancellous allografts. These pathological findings are similar to those reported in allografts contained by cortical host bone and support the hypothesis that incorporation of morcellised bone under metal meshes is not affected by these devices


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 125 - 125
1 May 2011
Pillai A Cherry V Siddiqui M Kumar S
Full Access

Background: The Calcaneus is the largest of the tarsal bones. 2% of all adult and 60 % of all tarsal fractures involve the Calcaneus. A true consensus regarding the management of these fractures still eludes orthopaedic surgeons. While operative treatment for displaced fractures has gained more acceptance in the last decade, surgical morbidity still remains high. Aim: A retrospective review of the early complications and radiological outcomes following open reduction and internal fixation of displaced calcaneal fractures in our unit over the last 15 months. Methods: A consecutive series of 33 patients who underwent surgical fixation of the Calcaneus was selected. Patient records, X rays and scans were reviewed. Mode and nature of injury, life style factors, surgical complications and Bohler’s angles were analysed. Results: 37 fractures in 33 patients underwent operative fixation. 81 % were male. Mean age at surgery was 37yrs (range19–59). 35 % were operated within 1 week of the injury and 13% after 2 weeks of injury. 43% were Sanders’ type III, 18% type II and 13% tuberosity avulsion fractures. 63% of patients had a reversed or zero Bohler’s angle. Mean post-op Bohler’s angle was 32 degrees. Overall complication rate was 32%, with a combined deep infection rate of 8%. All patients with infection were male, and 70% were smokers. 86% were above 40yrs of age (mean 47yrs). The deep infection rate for intra-articular fractures was 3% and for tuberosity avulsion fractures 40%. Majority of patients with wound complications had been operated within 7 days of injury. 4 patients had persisting pain requiring removal of metal work. Discussion: Our study highlights that there are significant risks associated with operative management of calcaneal fractures. Male patients over the age of 40yrs who are smokers seem to be at most risk of wound complications. Time to surgery or delay in surgery up to 2 weeks did not seem to have any adverse consequences. Complications increase with fracture complexity, and avulsion fractures have a high risk of wound breakdown. Near anatomical restoration of the articular surface is possible in most cases


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_II | Pages 144 - 144
1 Feb 2003
van der Jagt D Schepers A
Full Access

Resorption of the calcar below the collar of a titanium femoral prosthesis was observed. Biopsies of these lesions showed concentrations of polyethylene. We assessed the size of the resorption, correlating it with the size of the femoral prosthesis and the time since implantation. The age and the weight of the patient was also linked to the size of the prosthesis. We conducted a finite element analysis (FEA) of the femoral component-femur complex in both the loaded and unloaded situation. FEA demonstrated changing pressure under the collar. This can be translated into micro-bending, with the degree of movement dependent on the size of the prosthesis, the material of the prosthesis and the weight of the patient. We postulate the existence of a ‘polyethylene pump’ owing to the bending motion of the collared prosthesis, and that calcar resorption is due to the resultant polyethylene granulomatous lesions


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_IV | Pages 448 - 448
1 Apr 2004
van der Jagt D Schepers A
Full Access

Resorption of the calcar below the collar of a titanium femoral prosthesis was observed. Biopsies of these lesions showed concentrations of polyethylene. We assessed the size of the resorption and correlated this with the size of the femoral prosthesis and the time since implantation. The age and the weight of the patient were also linked to the size of the prosthesis. We conducted a finite element analysis (FEA) of the femoral component-femur complex in both the loaded and unloaded situation. The FEA study demonstrated changing pressure under the collar that can be translated into microbending motions, with the degree of the movement dependent on the size of the prosthesis, the material of the prosthesis and the weight of the patient. We hypothesise that the existence of a ‘polyethylene pump’ due to the bending movements of the collared prosthesis concentrates polyethylene particles under the collar. We therefore postulated that the calcar resorption is due to the polyethylene granulomatous lesions, resulting from the micromotion of the collar of the prosthesis


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_I | Pages - 78
1 Mar 2002
Papadopoulos A van der Jagt D Schepers A
Full Access

Between January 1990 and October 2000, 108 total hip arthroplasties using a cemented polished titanium stem and a cemented ultra-high molecular weight polyethylene (UHMWP) cup were performed at our hospital. Because during routine follow-up visits we noted instances of resorption of the calcar, we decided to assess whether this was a problem. We were able to assess 85 of the original 108 hips. Calcar resorption was observed in 43 hips. The extent of calcar resorption varied from 1 mm to over 15 mm. In one patient a biopsy showed typical polyethylene granuloma. Because there is a risk of long-term failure, we concluded that it is inadvisable to use a cemented polished titanium stem when UHMWP is one of the bearing surfaces


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_I | Pages 18 - 18
1 Mar 2005
van der Jagt D Schepers A
Full Access

We have previously reported on early lytic lesions occurring when collared titanium prostheses are used. Previous finite element analysis studies (FEAs) showed that lytic lesions of the calcar were due to concentration of polyethylene wear particles under the collar by a ‘pumping action’. Further follow-up of these calcar lytic lesions showed that their rate of increase in size progressively slowed down. Further FEAs were performed to determine why this was so. An FEA mesh construct was developed, incorporating the new parameters of no contact between the collar and the calcar bone. A mechanical model to determine displacement parameters was also developed. These FEA studies demonstrated that the pumping action of the collar became less efficient as the size of the lytic lesions increased. This led to less concentration of polyethylene particles under the collar and fewer granulomatous reactions. The change in the proximal prosthesis-cement-bone construct may lead to cement mantle deterioration and earlier failure. We still recommend caution when a collared prosthesis is used, and the material and geometry of the prosthesis remain important


The Bone & Joint Journal
Vol. 106-B, Issue 9 | Pages 879 - 883
1 Sep 2024
Kayani B Staats K Haddad FS


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XI | Pages 4 - 4
1 Apr 2012
Cherry V Pillai A Siddiqui M Kumar C
Full Access

A consensus regarding management of calcaneal fractures eludes orthopaedic surgeons. While operative treatment has gained more acceptance, surgical morbidity remains high. We undertook a retrospective review of early complications and radiological outcomes following internal fixation of calcaneal fractures in our unit over 15 months. A consecutive series of 33 patients who underwent fixation of the Calcaneus was selected. Patient records, X-rays and scans were reviewed. 37 fractures in 33 patients underwent fixation. 81 % were male. Mean age at surgery was 37yrs (19 -59yrs). 35 % were operated within 1 wk of injury and 13% after 2 wks of injury. 43% were Sanders' type III, 18% type II and 13% tuberosity avulsion fractures. 63% had a reversed/zero Bohler's angle. Mean post-op Bohler's angle was 32 degrees. Overall complication rate was 32%, with a combined deep infection rate of 8%. All patients with infection were male, and 70% were smokers. 86% were above 40yrs of age (mean 47yrs). The deep infection rate for intra-articular fractures was 3% and for tuberosity avulsion fractures 40%. Majority of patients with wound complications had been operated within 7 days of injury. Males over 40yrs and smokers seem to be at most risk of wound complications. Time to surgery/delay in surgery up to 2 wks did not seem to have any adverse consequences. Complications increase with fracture complexity and avulsion fractures have highest risk of wound breakdown. Near anatomical restoration of the articular surface is possible in most


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_III | Pages 363 - 363
1 Sep 2005
Van der Jagt D Schepers A
Full Access

Introduction and Aims: Rapidly progressive lytic lesions of the calcar develop under the collar of cemented titanium femoral stems inserted in our unit. Progression of the defects slowed after reaching a critical size. Biopsies showed granulomatous lesions with polyethylene particles and multi-nucleate giant cells. The aim of the study was to determine the natural history of these lytic lesions. Method: We developed a finite element analysis model. We determined the parameters of the FEA model, to reflect the geometry and physical characteristics of the prosthesis-bone construct and also factored in both loading and non-loading parameters. We also determined the characteristics of titanium and cobalt-chrome prostheses. Results: We determined from the FEA model that there is some vertical displacement of the collar relative to the calcar-cement construct. This displacement is larger in the titanium than the cobalt-chrome model. The magnitude of the displacement is larger than the average polyethylene particle size. On loading and non-loading this displacement allows the development of a pump action, thus concentrating polyethylene particles under the collar of the prosthesis and leading to the granulomatous lytic lesions. The FEA studies demonstrated that the pumping action of the collar became less efficient, but did persist, as the lytic lesions increased in size. Conclusion: We have explained the development of calcar lytic lesions under the collar of femoral stems. A pump action is present in loading and non-loading phases, sucking in polyethylene particles and allowing granulomatous lesions to form. We recommend caution when using collared femoral prostheses, more so titanium than cobalt-chrome, because of the development of calcar lytic lesions


The Bone & Joint Journal
Vol. 106-B, Issue 3 Supple A | Pages 67 - 73
1 Mar 2024
Laboudie P Hallé A Anract P Hamadouche M

Aims

The aim of this retrospective study was to assess the incidence of early periprosthetic femoral fracture (PFF) associated with Charnley-Kerboull (CK) femoral components cemented according to the ‘French paradox’ principles through the Hueter anterior approach (HAA) in patients older than 70 years.

Methods

From a prospectively collected database, all short CK femoral components implanted consecutively from January 2018 to May 2022 through the HAA in patients older than 70 years were included. Exclusion criteria were age below 70 years, use of cementless femoral component, and approaches other than the HAA. A total of 416 short CK prostheses used by 25 surgeons with various levels of experience were included. All patients had a minimum of one-year follow-up, with a mean of 2.6 years (SD 1.1). The mean age was 77.4 years (70 to 95) and the mean BMI was 25.3 kg/m2 (18.4 to 43). Femoral anatomy was classified according to Dorr. The measured parameters included canal flare index, morphological cortical index, canal-calcar ratio, ilium-ischial ratio, and anterior superior iliac spine to greater trochanter (GT) distance.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 590 - 590
1 Nov 2011
Goel DP Athwal GS Macdermid J
Full Access

Purpose: The success of humeral head replacement following fracture is reliant on several factors, one of which is version. The correct humeral version (HV) is highly variable, and is patient and side dependent. In the setting of fracture, there is no intra-operative landmark to guide the surgeon as to the anatomic version. This study has examined computed tomography (CT) of the shoulder and compared the HV to the metaphyseal version (MV) to evaluate reliability in predicting the anatomic version. Method: A retrospective review of 50 shoulder CT scans was carried out. Patients were excluded if the anatomy prevented HV or MV evaluation. The HV and MV was measured by 2 independent evaluators. Inter and intra-rater reliability was performed. Results: There were 27 right and 23 left shoulder CT’s reviewed. The mean age of patients was 45.3 (range 13–85). The difference between the MV and HV was approximately 2.8 (95% CI 0.63–5.1). Inter and intra-rater reliability was 0.966 and 0.984, respectively. Conclusion: Determining the version of the humeral head in the setting of fracture is difficult and highly inaccurate. The biceps groove has been previously cited as a landmark for arthroplasty position, however, given the anatomic variability, version may be miscalculated. We have demonstrated the medial calcar of the proximal humerus is within 3 degrees of the actual humeral head version. This CT guided approach is novel, reproducible and demonstrates excellent reliability. It is both accurate and consistent and may be successfully utilized in the setting where normal anatomic landmarks are absent, such as fracture


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_III | Pages 260 - 260
1 Mar 2004
Karachalios T Tsatsaronis C Efraimis G Papadelis P Lyritis G Diakoumopoulos G
Full Access

Aim: To evaluate long term effects of stress shieldieng phenomenon after cementless total hip arthroplasty. Materials-Methods: 80 female pts with OA were randomly allocated in 4 groups according to the type of the cementless stem which was primarily implanted (A-Zwey-Muller,B-Corail,C- Optifix,DAutophor900S). BMD changes of the operated hip (in seven zones), of the operated, contralateral normal hip and of the Lumbar spine were measured pre-op, at 2, 8 and 12 months and every year thereafter. Results: At ten years, 72 pts were available for follow up, all with satisfactory clinical and radiological results with no evidence of polyethylene wear or endosteal lysis. In all groups, the greatest reduction of BMD (calcar atrophyzone 7) was observed at the 2nd post-op year (A:24%, B:8%, C:14.8%, D:18.5%). In all groups, the greatest increase (zone 4) of BMD was also observed at the 2nd post-op year (A7%, B2%, C2.5%, D6.3%). In all groups a similar pattern of slow but progressive recovery of bone mineral density changes after the 3rd year was observed in both zones, approaching baseline values at 10 years in all groups. Preoperative lumbar BMD (osteopenia), body weight, sex and height were not statisticaly correlated to calcar atrophy. Conclusions:We suggest that the clinical and theoretical relevance of stress shielding phenomenon in total hip replacement has been overestimated in the literature


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_22 | Pages 48 - 48
1 Dec 2017
Demay O Renaud S Bredin S Diallo S Ohl X
Full Access

Aim

Chronic osteomyelitis of the calcaneus is a frequent problem in a population of diabetic patients, patients with neurologic disorders or bedridden patients with ulcers. Partial calcanectomy is an alternative option which avoid major amputation. The aim of this retrospective study was to determine the effectiveness of partial calcanectomy for treating chronic osteomyelitis of the calcaneux.

Method

We conducted a retrospective review of patients who underwent in our department a partial calcanectomy between 2006 and 2015. All patients with a complete set of radiographs and adequate follow-up (minimum 2 years) were included. We reviewed these cases to determine healing rate, microbiological analysis, risk factors of failure (comorbidities), limb salvage rate and survival rate. We analyzed specifically the footwear and the functional subjective evaluation according to the LEFS score (Lower Extremity Functional Scale).


The Journal of Bone & Joint Surgery British Volume
Vol. 57-B, Issue 4 | Pages 411 - 411
1 Nov 1975
Trickey EL


The Journal of Bone & Joint Surgery British Volume
Vol. 51-B, Issue 3 | Pages 494 - 497
1 Aug 1969
Lowy M

1. The literature on fractures of the postero-superior aspect of the calcaneus is reviewed.

2. The mechanical distinction between "beak" fractures and avulsion fractures is questioned, and the dangers of a purely radiological diagnosis are stressed.

3. When a complete avulsion is suspected on clinical grounds, open reduction should be done.


The Journal of Bone & Joint Surgery British Volume
Vol. 51-B, Issue 1 | Pages 118 - 122
1 Feb 1969
Protheroe K

1. Five cases of avulsion fracture of the calcaneus are reported.

2. The "beak" fracture of the calcaneus is thought to be a variant of the avulsion fracture and not a separate entity.

3. The variable attachment of the calcaneal tendon to the calcaneus is described, and its relationship to the different forms of avulsion fractures discussed.

4. Operative reduction and fixation are appropriate for young and active patients in order to restore full heel-cord function.

5. Attention is drawn to the risk of pressure necrosis of skin overlying a displaced fragment. Early operative correction may be required to prevent skin damage.


The Journal of Bone & Joint Surgery British Volume
Vol. 45-B, Issue 2 | Pages 360 - 363
1 May 1963
Hooker CH

1. The clinical aspects of fifty-six patients with rupture of the tendo calcaneus are discussed, and the mechanism of injury is described.

2. Operative repair of the rupture is considered with a study of the results in twenty-eight patients.


The Journal of Bone & Joint Surgery British Volume
Vol. 49-B, Issue 4 | Pages 695 - 697
1 Nov 1967
Hall JE Salter RB Bhalla SK

1. Twenty patients with congenital short tendo calcaneus are described.

2. All were treated by tendon lengthening and followed up for one and a half to seven years.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_III | Pages 267 - 268
1 Mar 2004
Karachalios T Boscainos P Bargiotas K Roidis N Vagianos E Malizos K
Full Access

Aim: Evaluation of intermediate clinical and radiographic results of displaced intra-articular fractures of the calcaneus treated with ORIF. Materials- Methods: From 1994 to 2002, 167 displaced intra-articular fractures of the calcaneus were treated with ORIF. There were 145 male and 12 female patients. Mean age 34 years. Standard x-rays, Broden views and CT-scan images in coronal and transverse plane were obtained pre and post operatively. Fractures were classified as type III, IV, V according to Sanders. All fractures were approached through an extended lateral L-type approach. AO calcaneal plate was used. Average follow-up was 5 years. Results: In 143 Sanders type III and IV fractures KITA-OKA score was 91. Reduction failure rate was 5.5%(8 pts). 24 patients had Sanders type V fractures and KITAOKA score was 84 and reduction failure rate was 25% (6 pts). 29/167 patients complained of peroneal tendons tenderness which subsided after hardware removal. 79/167 patients had restriction of subtalar joint movements but no complains (SF_36) There were two superficial wound infections and five patients with delayed wound closure. In a group of 45 patients with similar fracture patterns who were treated conservatively, KITA-OKA score was 71, 41 fractures were malunited, 40 patients had moderate to severe pain and early OA sings. Conclutions: Displaced intra-articular fractures of the calcaneus should be treated as any other displaced intra-articular fracture, with open reduction and stable internal fixation


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_III | Pages 268 - 268
1 Mar 2004
Drjagin V Kuropatkin G
Full Access

Aims: The purpose of this study is comparative analysis of different surgical methods of calcaneal fractures treatment. Methods: From 1992 to 2001 we treated 132 patient (161 feet) with displaced intra-articular fractures of the calcaneus. All of these fractures have been classified according to the Essex-Lopresti Rx classification. 7 fractures were type A, 14 – type B1, 22 – type B2. Type C1 occurred in 51 cases, type C2- in 58 and type D – in 9 cases. 113 patients (134 feet) had fresh trauma (2–10 days after injury) and in 18 cases (27 feet) 3 up to 6 weeks passed from the moment of the injury. In 52 cases (62 feet) we used closed reduction and external fixation with Ilizarov apparatus. In other AO-implants were used: reconstruction 3,5 mm plate (19 cases), T-plate (12 cases), “Tampa plate”(59 feet) and new Locking Calcaneal Plate (9 feet). All patients underwent pre- and postoperative standard lateral and axial X-Ray and CT-scans. Follow-up results were analysed through 6 and 12 months. Results: Good and excellent results (no pain, no deformities and good function) were obtained in 74,2% patients, satisfactory results – in 18,2% of cases. In 7 patients the superficial skin necrosis was observed, in 5 cases deep wound infection developed. The best results are received in cases of Locking Calcaneal Plate application. Conclusions: Fractures of the calcaneus should be treated like other intra-articular fractures, i.e. careful reduction, stable fixation and early mobilization. Indirect reduction and external fixation can be applied only in A and B1-type of fractures. In fractures of B2 and C types good results can be obtained only by using stable osteosynthesis. In D-type fractures and neglected/delayed C2-fractures it is better to apply a primary sub-talar arthrodesis.


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 6 | Pages 994 - 997
1 Nov 1991
Fraser R Hoffman E

We reviewed our experience of tibialis anterior transfer and anterior release for calcaneus deformity in 46 feet of 26 ambulant patients with myelomeningocele. At an average follow-up of 8.4 years (2 to 17.6) there were 89% who had satisfactory results; 64% of the patients having tibialis anterior transfers were able to stand on their toes. Hip abductor power was a good predictor of a functional transfer. Pre-operative trophic ulceration of the heel increased from 3.2% to 33% if surgery was delayed. Secondary deformities, two-thirds of them into valgus, developed in 76% of feet.


The Journal of Bone & Joint Surgery British Volume
Vol. 57-B, Issue 4 | Pages 413 - 421
1 Nov 1975
Soeur R Remy R

The thalamus is the part of the calcaneus that supports the posterior articular facet and continues forward, becoming thinner towards the groove of the sinus tarsi. The main displacements after fracture depend on 1) a primary fracture line dividing the bone into anterior and posterior fragments, and 2) a semilunar fragment in the thalamic region. In the operation advised the sinus tarsi is exposed and the semilunar fragment is reduced by rotation in the opposite direction and is fixed to the medial fragment (the sustenaculum tali not being displaced) by a transverse Kirschner wire. The two main fragments are fixed by an antero-posterior wire. Plaster is applied and is retained for twelve weeks. Weight-bearing is not permitted for the first four weeks. There were no major complications in fifty-eight operations. The anatomical results were good: restoration of the tuber-joint angle by reduction of the semilunar fragment was maintained. The functional results were very satisfactory: permanent disability was slight or mild.


The Journal of Bone & Joint Surgery British Volume
Vol. 35-B, Issue 1 | Pages 46 - 49
1 Feb 1953
Cholmeley JA

1 . Paralytic talipes calcaneus and calcaneo-cavus are difficult deformities to correct and keep corrected. Many operations have been devised for this purpose.

2. Emslie's operation is a simple procedure by which satisfactory correction can be obtained and maintained. It can be modified to suit individual cases without altering the basic principles of the procedure and is physiologically sound.

3. Illustrative cases are described.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_III | Pages 267 - 267
1 Mar 2004
Korobushkin G Skorogljadov A Kopenkin S
Full Access

Aims: The goal of this study to compare the clinical outcome of patients with calcaneus fractures differential strategy and non-differential conservative strategy treated. Methods: The study based on the results of treatment of 122 patients with 140 heel bone fractures. Results of only conservative treated 52 patients (54 fractures) in period 1992–1999 were retrospectively evaluated. Results of 70 patients (86 fractures) differential strategy treated in period 1999–2001 were prospectively evaluated. The plain radiographs – that is lateral, antero-posterior, oblique radiographs of the foot, axial and Broden view – and computerized tomography were used for examine patients. In period 1999–2001 the patients were differential strategy treated. All patients were divided in 5 groups: non-displacement fractures (early range of motion), beak type fractures (close reduction internal fixation by cannulated screw), tongue-type fractures (axial reposition axial fixation by Schantz screw), jointdepression and comminuted fractures (ORIF calcaneus bone plate AO). The results were evaluated by own score system in first group in 4 – 8 years period and 1 – 2,5 years period in second group. Results: The results of differential strategy treated patients with heel bone fractures (excellent – 60,9%± 5,9, good – 29,0%± 4,8, fair – 5,8%± 2,4, bad – 4,3%± 2,1) were reliably (p≥95%) better than results in only conservative treated group (excellent – 26,8%±4,7, good – 23,9%±4,5, fair – 23,9%±4,5, bad 25,4%±4,6). Conclusions: This study demonstrates that the differential strategy of treatment allows to reach good results and minimize soft tissue trauma.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_III | Pages 268 - 268
1 Mar 2004
Matej A
Full Access

Aims: In prospective study the author asked, what are the results of ORIF (open reduction, internal fixation) in displaced intraarticular fractures of the calcaneus, and whether type of fracture and/or congruity in the sub-talar joint influence these results. Methods: Forty-three displaced intraarticular fractures of the calcaneus (30 Type II, 10 Type III and 3 Type IV; Sanders) were operated through extensile lateral approach. After reduction of the subtalar joint and restoration of the calcaneus shape, the fracture was fixed with the calcaneal plate. Mostly, surgery was delayed (median: day 7). Motion was encouraged immediately, partial weight-bearing after 5–6 weeks, and full weight-bearing after 3–4 month. Following surgery subtalar joint was congruent in 33 (77%) and non-congruent (within 2mm) in ten fractures. Results: Thirtysix fractures were evaluated 12 to 61 months postinjury. Functional results were satisfactory in 31 fractures (86%) and not satisfactory in five. All fractures with unsatisfactory results were comminutive (Type III or IV). Four fractures with congruent subtalar joint had unsatisfactory, whereas eight of nine fractures with uncongruent joint had satisfactory result. Statistically, functional results of the comminuted fractures were significantly worse (p=0,002). However, functional results of fractures with non-congruent joint were comparable to the results of fractures with congruent joint. Conclusions: ORIF enables satisfactory results in majority of displaced intraarticular fractures of the calcaneus. Comminution in the subtalar joint is a negative prognostic factor; furthermore, comminution is a negative prognostic factor irrespectless of the postreduction congruity in the subtalar joint, if step-off is less than 2mm.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 82 - 82
1 Mar 2010
Lorente TS Muñoz FL Campos FF
Full Access

Introduction and Objectives: Our aim was to study the clinical and work-related results of minimally invasive athrodesis in the treatment of severe calcaneus fractures.

Materials and Methods: A total of 50 fractures (42 patients) with intraarticular calcaneus fractures were treated by means of a minimally invasive primary arthrodesis using the VIRA® (Biomet, Valencia, Spain) system with a minimum follow-up of 12 months and a mean follow-up of 21 months. Mean age was 41 years of age. Eight procedures were bilateral and 3 open. According to Sanders classification 74% were type IV. We performed a prospective study with clinical and radiographic assessment (AOFAS scale) 12 months after surgery.

Results: The mean AOFAS score was 76.6 points (SD: 13.97): 26% were very good, 62% good and 12% fair to poor. There was no statistical variation of AOFAS in Sanders type of fracture, whether or not the lesion was bilateral and whether or not there was an associated lesion. We found an association (p=0.06) between the AOFAS score and the previous health status of the patient. Böhler’s angle improved slightly, although significantly (p=0.05), and there was seen to be correspondence with the postoperative AOFAS scale. Subtalar arthrodesis was achieved in 48 cases (96%) at 3 months.

Discussion and Conclusions: Primary arthrodesis using minimally invasive systems is a valid option for the surgical treatment of severe fractures of the calcaneus. It provides good clinical and radiological outcomes with minimally aggressive surgery and a low complication rate.


The Journal of Bone & Joint Surgery British Volume
Vol. 56-B, Issue 2 | Pages 274 - 278
1 May 1974
St C. JF

1. In a severe crush fracture of the calcaneus part of the lateral cortex may be displaced to lie under the tip of the lateral malleolus. This may cause local pain and tenderness, either by direct bony abutment or by compression of the peroneal tendons.

2. Such pain is usually relieved by excision of the tip of the lateral malleolus, a minor procedure.

3. Four of the five patients reported were completely relieved of lateral pain, and the fifth has only slight residual discomfort.

4. It is important to be aware of this lesion and not to advise subtalar or triple fusion when simple excision of the tip of the fibula would suffice.


The Journal of Bone & Joint Surgery British Volume
Vol. 52-B, Issue 2 | Pages 334 - 336
1 May 1970
Fisher TR Woods CG

1. A case of ossification and partial rupture of the tendo calcaneus is reported.

2. The possible etiology of the ossification and its relationship to the rupture is discussed.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXVIII | Pages 26 - 26
1 Jun 2012
Young P Bell S MacDuff E Mahendra A
Full Access

Bony tumours of the foot account for approximately 3% of all osseous tumours. However, literature regarding os calcis tumours comprises individual case reports, short case series or literature reviews, with the last large case series in 1973.

We retrospectively reviewed the medical notes and imaging for all patients with calcaneal tumours recorded in the Scottish Bone Tumour Registry since the 1940's. Demographics, presentation, investigation, histology, management and outcome were reviewed.

38 calcaneal tumours were identified. Male to female ratio 2:1, mean age at presentation 30 with heel pain and swelling, average length of symptoms 9 months. 4 cases present with pathological fracture. 24 tumours benign including 6 unicameral bone cysts, 3 chondroblastoma, 3 PVNS with calcaneal erosion, and a wide variety of individual lesions. 13 malignant tumours comprising 6 osteosarcoma, 5 chondrosarcoma and 2 Ewings sarcoma. 1 metastatic carcinoma.

Tumours of the calcaneus frequently are delayed in diagnosis due to their rarity and lack of clinician familiarity. They are more common in men and have a 1 in 3 risk of malignancy, covering a wide variety of lesions. Outcome is dependent on early diagnosis, timely surgery and most importantly neo-adjuvant chemotherapy. Diagnosis is often made on plain radiograph but MRI is the gold standard.

We present the largest case series of calcaneal tumours, from our experience with the Scottish Bone Tumour Registry. Despite their rarity clinicians should maintain a high index of suspicion as accurate and timely diagnosis is important to management and outcome.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 124 - 124
1 May 2011
Karavolias C Stafylakis D Klonaris M Tiliakos M Konstantinidis I Nomikarios D Sokorelos M
Full Access

Purpose: We assess the results of the surgical treatment of intra-articular fractures of the calcaneus using the Ilizarov external fixator.

Materials and Methods: During the period of January 2004 to June 2009 we treated 72 intra-articular calcaneus fractures in 68 patients, 51 male and 17 female with a mean age of 34 (range 18–56). The mean follow –up period was 2 years and 10 months (range 3 months to 4 years). All patients received preoperative CT-scan to facilitate classification and pre-operative planning. Of the 72 fractures, 37 (51.4%) were Sanders type II, 30 (41.6%) were type III and 5 (7%) were type IV.

The Ilizarov fixator used consisted of 2 rings positioned above the ankle joint and a foot plate. 1.5 and 1.8 mm wires were used, as well as 1.8 mm wires with an olive for the reduction of displaced fragments. Under image intensification and distraction the fracture was reduced and the articular surface was restored as close as possible.

Results: The clinical outcome was excellent in 29 patients (40.4%), good in 32 (44.4%), moderate in 7 (9.7%) and poor in 4 (5.5%). As far as the complications are concerned, we had 17 cases of pin track infection treated with the removal of the pins, ankle joint stiffness in 12 patients treated with physiotherapy, 2 patients developed reflex sympathetic algodystrophy, 2 malunion, 8 developed post-traumatic osteoarthritis and 1 of them underwent subtalar arthrodesis.

Conclusion: The use of the Ilizarov external fixator for the treatment of intra-articular calcanear fractures has proved itself to be an alternative method to O.R.I.F with similarly good results. Given the fact that the learning curve is relatively steep, it has proven, from our experience, to be a safe and valuable tool for the treatment of these challenging fractures.


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_III | Pages 249 - 250
1 Mar 2003
Blanckley S Walker C
Full Access

Controversy exists regarding the management of intra-articular fractures of the calcaneus. We present medium-term outcome data on 37 consecutive patients who underwent open reduction and internal fixation for comminuted intra-articular calcaneal fractures.

Operations were performed by one surgeon, CRW, following CT assessment of the fracture. All procedures were performed using an extensile lateral approach and early physiotherapy was standard. Case notes were reviewed retrospectively between three months and five years post-operatively. Patients were also invited to attend a follow-up clinic where outcomes were assessed using the American Orthopaedic Foot and Ankle Society Hind Foot Score and were questioned regarding on-going problems, change in shoe size and return to work.

Complete data is available for 16 patients, with additional information from other patients. Results show average AOFAS scores for type II fractures to be 59/100, type III to be 81/100 and 79/100 for type IV fractures. We have shown low rates of complications – one infection, three patients requiring a change in shoe size and an average return to work of seven months.

We have shown good medium-term outcome results for the operative management of displaced intra-articular fractures and to answer our question, we believe we should be operating on them.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_13 | Pages 7 - 7
1 Sep 2014
Ajai A
Full Access

The lack of a universal, consistent protocol for the subjective, objective and radiographic evaluation of these injuries has hampered the comparison of results.

Methods

45 patients with complex fractures of the calcaneus were included in this prospective study, which was undertaken from July 2003 to December 2005. The fracture classification of Essex-Lopresti was used. We also observed the extent of secondary fracture lines extending from the primary shear line (on axial and external oblique plain radiographs) to establish comminution. The external oblique view for subtalar joint was performed with the patient supine, the knee at about 60 degree of flexion and the limb rotated externally 45 degree with a vertical X ray beam. All of these patients were managed by an external fixator using the principle of ligamentotaxis. Patients were evaluated by AOFAS.

Results

We identified two broad patterns of secondary lines on plain X-rays:

with anterior secondary fracture lines and

with posterior secondary fracture lines.

There were 20 cases of tongue type and 25 of joint depression type fracture pattern by the Essex-Lopresti classification. Forty two (93.4%) patients had fractures with posterior secondary fracture line and 3 (6.7%) patients had anterior secondary lines.

The calcaneo-cuboid type of anterior secondary line pattern was present in 2 (4.5%) cases, and the plantar type in only 1 (2.5%) case.

We observed posterior secondary line Type A pattern in 2 (4.5%) cases, depression / central depression type B in 20 (44.5%) cases, tongue shaped Type C pattern in 16 (36.5%) cases and Type D severely comminuted fracture line pattern in 4 (8.7%) cases.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 178 - 178
1 Mar 2010
Isaacs J Baba M Szomor Z
Full Access

Böhler’s historical tuber-joint angle of the calcaneus has been used since 1931. Surprisingly, there is a paucity of literature on the topic. The aims of this study were to confirm the normal range for Böhler’s angle and determine the angle with the highest accuracy in the diagnosis of calcaneal fractures.

A retrospective cohort study was performed. Data were obtained from The St George Hospital digital Picture Archival and Communication System (PACS) and through a review of medical records. The study cohort comprised 212 consecutive patients diagnosed with calcaneal fractures on CT scan, spanning a five-year period from April 2003 to March 2008. An additional 212 patients with normal lateral foot radiographs were used to determine the normal range. Böhler’s angle was measured by two independent observers on lateral xray using the digital angle tool from PACS. Data were analysed using Stata 8 statistical software package.

This is the largest study to our knowledge that examines the diagnostic accuracy of Böhler’s angle in fractures of the calcaneus. Contrary to many texts but true to Böhler’s assertions, the mean Böhler’s angle in patients without calcaneal fracture was 29.4 degrees (95% CI, 28.9–30.0 degrees). In this group there was no difference in Böhler’s angle between male and female patients (p> .05), left and right feet (p> .05) or across age (ANOVA, p> .05). In those patients with calcaneal fractures, a Böhler’s angle below 25 degrees was moderately predictive of calcaneal fracture (sensitivity = 100%, specificity = 82%, PPV = 85%, NPV = 100%, LR+ = 5), an angle below 23 degrees was highly predictive of calcaneal fracture (sensitivity = 100%, specificity = 89%, PPV = 90%, NPV = 100%, LR+ = 9) and an angle below 21 degrees was strongly suggestive of calcaneal fracture (sensitivity = 99%, specificity = 99%, PPV = 99%, NPV = 99%, LR+ = 110). A Böhler’s angle of less than or equal to 20 degrees had the highest diagnostic accuracy as there were only two false negatives and one false positive from a total of 424 patients.

A Böhler’s angle of 20 degrees or less is highly accurate in determining the presence or absence of calcaneal fracture. These findings are of particular importance when fracture is uncertain as it gives the surgeon a definitive reference point when using Böhler’s angle for assessment of fracture of the calcaneus.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_10 | Pages 18 - 18
1 Jul 2014
Sinha A Selvan D Sinha A James L
Full Access

We present our experience of using tension band plates to achieve guided growth in children for correction of calcaneus deformity of the ankle.

11 consecutive patients (13 ankles) fulfilled the inclusion criteria over a 4-year period. All underwent surgical treatment using a flexible two hole plate and screws on the posterior aspect of distal tibial physis. Measurements were done on preoperative, intraoperative screening and 1-year post operative plain AP and lateral ankle radiographs. The anterior distal tibia angle (ADTA), lateral distal tibial angle (LDTA) and screw divergence angle (angle subtended by lines passing through the long axis of the screws) were used to assess the deformity correction. A 2 tailed student t-test was carried out on the initial and 1-year post-op measurements to determine statistical significance with a p value <0.05 considered as significant

There were 10 residual clubfoot deformities, 2 post-traumatic deformities and 1 spinal tumor causing deformity. The average age of the patients was 10 years 5 months (range 4 to 13 years). There were 9 males and 2 females. The ADTA showed a statistically significant change with a p value of 0.0008 with a mean correction of 8.6 degrees (range of 2.3 to 15.6 degrees). The SDA demonstrated a mean correction of 15.4 degrees (range 0.3 to 41.8 degrees), p=0.002. The LDTA did not change significantly (p= 0.08), thus confirming no coincidental coronal plane deformity had occurred. 5 ankles required revision of fixation due to metalwork reaching its maximum limit of divergence at an average of 1 year. 2 ankles had screw pulled out due to osteolysis around the screw. There were no cases of infection.

We report satisfactory short-term results of correction of calcaneus deformity using a flexible tension band plate and screws system.


The Journal of Bone & Joint Surgery British Volume
Vol. 53-B, Issue 1 | Pages 96 - 100
1 Feb 1971
Koutsogiannis E

1. Thirty-four cases of calcaneal osteotomy for mobile flat foot in nineteen patients are reviewed.

2. The function was markedly improved in seventeen of the nineteen patients.

3. The operation was successful in correcting the valgus deformity of the heel in thirty of the thirty-four feet. it was less successful in improving the longitudinal arch, especially when the flat foot deformity was severe.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 79 - 79
1 Mar 2009
Badila A Radulescu R Cirstoiu C Nutiu O Manolescu R Nita C Popescu D Dinu A
Full Access

Aim: To compare 2 methods of osteosynthesis (pinning and plate and screws) in displaced intraarticular fractures of the calcaneus

Material and method: Between 2001 and 2005, 82 displaced intraarticular fractures of the calcaneus were surgically treated in our department. Fractures were classified according to Bohler’s classification: 18 Bohler type II and 64 Bohler type III fractures.

Open reduction and reconstruction with osseous grafts (autologous grafts in 22 cases and heterologous grafts in 52 cases) were used in 74 cases. In 8 cases (all of Bohler II type) grafts weren’t used. Osteosynthesis with plate and screws was performed in 26 cases and with pins in 56. The 2 groups were similar in what concerns age, sex ratio, BMI, degree of comminution. The surgical procedure was delayed in both groups (average − 6 days). Pins were removed at 6 weeks and the plates at 12 months.

Results: A number of clinical parameters (pain evolution, moment of partial and full weight bearing, achievement of clinical and radiological union, ankle and forefoot mobility, etc.) were similar in both groups. Skin complications were more frequent in the plate group even if similar lateral surgical approaches were used. Pain along peroneal tendons was much more frequent in the plate group.

Conclusions: Even if theoretically osteosynthesis with plate and screws assures a better fixation, in practice it has similar clinical results with the pinning. The number of complications is higher after plate osteosynthesis. The pins can be extracted with local anesthesia, while plate extraction requires lumbar or general anesthesia and a full extent surgical procedure.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_I | Pages 22 - 22
1 Mar 2006
Ng B Soong V Sankar B Siddique I Maguire M Mohil R Henderson A
Full Access

Purpose: To evaluate the objective outcomes in patients who had undergone hardware removal after ORIF of calcaneus fractures.

Materials and Methods: Between 1994 and 2002, 31 cases of hardware removal was performed in 30 patients (25 male, 5 female) with an average age at operation of 47 years (31 to 65 years) were reviewed. Patients’ demographic details were recorded including smoking habit. Fracture patterns were graded according to the Sanders’ classification with preoperative CT scans. The clinical result was assessed using Bristol hind foot scoring system. Serial radiographs assessments were also recorded.

Results: Average follow-up was 4.5 years. Average delay from time of injury to surgery was 12.4 days (range 5 to 24 days). 7 (23%)fractures were Sanders’ type 2A, 8 (26%)fractures were type 2B, 6 (19%)fractures were type 2C, 2 (6%) fractures were type 3AB and 8 (26%) fractures were type 3AC. Average time from surgery to hardware removal was 27 months (range 11 to 45 months). There were 16 smokers and 14 non-smokers. There were 5 deep infections and 3 superficial wound infections after ORIF of calcaneus fractures. 84% of the patients shown objective improvement following hardware removal at the latest follow-up. 2 patients had unsuccessful hardware removal due to dense scarring. No wound infections were recorded. Smoking habit had no significant bearing on the objective outcome improvement following hardware removal (p= 0.891), time from surgery to hardware removal (p=0.53) and wound morbidity (p= 0.4882). Objective improvement showed a statistically significant improvement in the Sanders’ type 2 compared with Sanders’ type 3 (p=0.015).

Conclusion: Removal of hardware is justified in symptomatic patients following ORIF calcaneus fractures. It results in an improved objective outcome and has a low complication rate. Hardware removal may be considered in cases of Sanders’ type 2 calcaneus fractures which are refractory to improvement.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_III | Pages 268 - 268
1 Mar 2004
Burssens P van Ovost E Verdonk R
Full Access

There are many reports of treatment for intraarticular fractures of the calcaneus using different methods. Results are very difficult to compare. For this reason a prospective study was designed to compare the outcome of the same type of fracture treated with Stein-mann pinning or plate osteosynthesis.

Between January 1995 and March 1999 31 patients with two-part intraarticular fractures of the calcaneus, type IIB according to the Sanders classification, were treated operatively with either transcalcaneal pinning (12 fractures) or with open reduction and internal plate and screw fixation using a lateral approach (19 fractures). After a mean follow-up of 26 months all patients were assessed. A comparison was made between the two modes of treatment. The global score averaged 78.3 ± 12.1; 79.3 ± 11.14 for the patients treated with plate and screw fixation, and 76.6 ± 13.2 for the patients who underwent pinning. Lateral X-rays showed no difference in anatomical reduction between both methods. A positive correlation was demonstrated between the AOFAS Ankle-Hindfoot score and Böhler’s angle. The restoration of the congruity of the posterior subtalar joint was assessed postoperatively by means of a CT scan. The angle between the undersurface of the talus and the lateral fragment of the two-part fracture was evaluated. No statistically significant difference was found between both groups.

The authors conclude that there is no difference in functional outcome between both modes of treatment. Plate osteosynthesis has the advantage that the shape of the hindfoot and midfoot is restored, but the higher complication rate is a drawback.