Advertisement for orthosearch.org.uk
Results 1 - 50 of 193
Results per page:
The Bone & Joint Journal
Vol. 103-B, Issue 11 | Pages 1717 - 1724
1 Nov 2021
Singh HP Haque A Taub N Modi A Armstrong A Rangan A Pandey R

Aims. The main objective of this study was to examine whether the Oxford Shoulder Score (OSS) demonstrated floor or ceiling effects when used to measure outcomes following shoulder arthroplasty in a large national cohort. Secondary objectives were to assess its pain and function subscales, and to identify independent predictors for patients achieving a postoperative ceiling score following shoulder arthroplasty. Methods. Secondary database analysis of the National Joint Registry (NJR), which included 48,270 patients undergoing shoulder arthroplasty, was conducted. The primary outcome measure was the OSS. Secondary outcome measures were the OSS-Function Component Subscale and OSS-Pain Component Subscale. Floor and ceiling effects were considered to be present if > 15% of patients scored either the lowest or highest possible score. Logistic regression analysis was used to identify independent predictors for scoring the highest possible OSS score postoperatively. Results. Preoperatively, 1% of patients achieved the lowest possible OSS score (0) and 0.4% of patients achieved the highest possible score (48). Postoperatively, < 1% of patients achieved the lowest score at all timepoints, but the percentage achieving the highest score at six months was 8.3%, at three years 16.9%, and at five years 17%. Male patients, those aged between 60 and 89 years, and those undergoing an anatomical total shoulder arthroplasty (ATSA) were more likely to contribute to the ceiling effect seen in the OSS questionnaire. Pain and function subscales exhibited greater ceiling effects at three years and five years when compared with the overall OSS questionnaire. Logistic regression analysis showed that sex, procedure type, and preoperative OSS score were independent predictors for scoring the highest possible OSS at years. Conclusion. Based on NJR patient-reported outcome measures data, the OSS does not exhibit a ceiling effect at six months, but does at three years and five years, in part due to outcome scores of ATSA. Preoperative OSS, age, male sex, and ATSA are independent predictors of achieving a ceiling score. Cite this article: Bone Joint J 2021;103-B(11):1717–1724


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_18 | Pages 6 - 6
1 Dec 2014
Lamb JN Varghese M Venkateswaran B
Full Access

This study aims to correlate Oxford shoulder score (OSS) to EQ5D score in healthy patients presenting to a shoulder clinic with shoulder pain. OSS and EQ5D scores were collected prospectively from 101 consecutive patients presenting with shoulder pain in a shoulder clinic at one specialist centre. Patients with ASA > 2 and other significant joint arthritis were excluded from the study. Scores were collected from electronic patient records. Spearman's rho correlation of oxford shoulder scores and EQ5D scores was completed. Mean age of subjects was 51.8 (range 19.1–81.9) years, 55 of 101 subjects were men (54%). Median OSS was 26 (range 3–48) and median EQ5D score was 0.76 (range 0–0.76). Correlation for all patients was 0.624 (Sig p<0.001). This study demonstrates a strong correlation between Oxford shoulder scoring and EQ5D in a fit and well shoulder surgery clinic population. It is possible that Oxford shoulder scores may be a useful indicator of quality of life in healthy shoulder clinic patients presenting with shoulder pain


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 113 - 113
23 Feb 2023
Fang Y Ackerman I Harris I Page R Cashman K Lorimer M Heath E Graves S Soh S
Full Access

While clinically important improvements in Oxford Shoulder Scores have been defined for patients with general shoulder problems or those undergoing subacromial decompression, no threshold has been reported for classifying improvement after shoulder replacement surgery. This study aimed to establish the minimal clinically important change (MCIC) for the Oxford Shoulder Score in patients undergoing primary total shoulder replacement (TSR). Patient-reported outcomes data were sourced from the Australian Orthopaedic Association National Joint Replacement Registry Patient-Reported Outcome Measures Program. These included pre- and 6-month post-operative Oxford Shoulder Scores and a rating of patient-perceived change after surgery (5-point scale ranging from ‘much worse’ to ‘much better’). Two anchor-based methods (using patient-perceived improvement as the anchor) were used to calculate the MCIC: 1) mean change method; and 2) predictive modelling, with and without adjustment for the proportion of improved patients. The analysis included 612 patients undergoing primary TSR who provided pre- and post-operative data (58% female; mean (SD) age 70 (8) years). Most patients (93%) reported improvement after surgery. The MCIC derived from the mean change method was 6.8 points (95%CI 4.7 to 8.9). Predictive modelling produced an MCIC estimate of 11.6 points (95%CI 8.9 to 15.6), which reduced to 8.7 points (95%CI 6.0 to 12.7) after adjustment for the proportion of improved patients. For patient-reported outcome measures to provide valuable information that can support clinical care, we need to understand the magnitude of change that matters to patients. Using contemporary psychometric methods, this analysis has generated MCIC estimates for the Oxford Shoulder Score. These estimates can be used by clinicians and researchers to interpret important changes in pain and function after TSR from the patient's perspective. We conclude that an increase in Oxford Shoulder Scores of at least 9 points can be considered a meaningful improvement in shoulder-related pain and function after TSR


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 85 - 85
10 Feb 2023
Fang Y Ackerman I Harris I Page R Cashman K Lorimer M Heath E Graves S Soh S
Full Access

While clinically important improvements in Oxford Shoulder Scores have been defined for patients with general shoulder problems or those undergoing subacromial decompression, no threshold has been reported for classifying improvement after shoulder replacement surgery. This study aimed to establish the minimal clinically important change (MCIC) for the Oxford Shoulder Score in patients undergoing primary total shoulder replacement (TSR). Patient-reported outcomes data were sourced from the Australian Orthopaedic Association National Joint Replacement Registry Patient-Reported Outcome Measures Program. These included pre- and 6-month post-operative Oxford Shoulder Scores and a rating of patient-perceived change after surgery (5-point scale ranging from ‘much worse’ to ‘much better’). Two anchor-based methods (using patient-perceived improvement as the anchor) were used to calculate the MCIC: 1) mean change method; and 2) predictive modelling, with and without adjustment for the proportion of improved patients. The analysis included 612 patients undergoing primary TSR who provided pre- and post-operative data (58% female; mean (SD) age 70 (8) years). Most patients (93%) reported improvement after surgery. The MCIC derived from the mean change method was 6.8 points (95%CI 4.7 to 8.9). Predictive modelling produced an MCIC estimate of 11.6 points (95%CI 8.9 to 15.6), which reduced to 8.7 points (95%CI 6.0 to 12.7) after adjustment for the proportion of improved patients. For patient-reported outcome measures to provide valuable information that can support clinical care, we need to understand the magnitude of change that matters to patients. Using contemporary psychometric methods, this analysis has generated MCIC estimates for the Oxford Shoulder Score. These estimates can be used by clinicians and researchers to interpret important changes in pain and function after TSR from the patient's perspective. We conclude that an increase in Oxford Shoulder Scores of at least 9 points can be considered a meaningful improvement in shoulder-related pain and function after TSR


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_18 | Pages 9 - 9
1 Apr 2013
Kosy J Bradley BM Hawken R Ramesh R Conboy V
Full Access

The use of scoring systems for surveillance of post-operative outcomes is increasing. However, the methodology of this follow-up is not universal. We set out to assess whether a postal Oxford Shoulder Score (OSS) was sufficient to identify patients who were dissatisfied and wanted further treatment. Of 88 patients who had undergone GlobalCap resurfacing in the previous 5 years, we received a completed postal OSS (Median score 33, Range 5–48) from 80 patients. Those with a score <24 (an agreed threshold for surgery pre-operatively) were brought to clinic for review. The 16 recalled patients (2 males, 14 females; age 58–85) had their OSS repeated, supervised by a clinic nurse, and had a Constant Score and an American Shoulder and Elbow Surgeons (ASES) Score performed. Satisfaction was also questioned. OSS correlated well with the Constant Score (r=0.79) and ASES (r=0.86). However, supervision increased the OSS by an average of 6 points (Mean 13.9 to 19.9) and only three of the patients proved dissatisfied with the outcome of their surgery. Used alone, an unobserved OSS may have limited value for this purpose and the use of comparative pre-operative scores or additional patient-reported outcome measures may be necessary to detect poor outcomes


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 352 - 352
1 Jul 2008
Baker P Nanda R Goodchild L Finn P Rangan A
Full Access

Introduction: Scoring systems for assessment of shoulder function are invaluable tools in determining changes in a patient’s condition. We utilised two commonly used assessment tools in patients with conservatively treated proximal humeral fractures to establish their behaviour in this patient group.

Methods: OSS and Constant Scores were collected prospectively at 3 and 12 months post injury, for 103 consecutive patients treated conservatively for proximal humeral fractures. Comparison of the scores was undertaken by creating scattergraphs, calculating Pearson’s correlation coefficient and producing Bland and Altman plots. Sensitivity to change was calculated using paired t-tests. Linear regression analysis was finally performed to predict Constant Score from the OSS.

Results: 177 sets of scores were collected. The scores correlated well with a correlation coefficient (r) of 0.84 (p< 0.001,n=177). This relationship was equally strong at 3 (r=0.77 (p< 0.001,n=94)) and 12 months (r=0.87 (p< 0.001,n=83)) and demonstrated a clear relationship between the scoring systems. Bland and Altman plots showed good agreement between the scores. Both scores were sensitive to change over time (OSS (t(81)=6.14,p< 0.001), Constant (t(80)=−10.27,p< 0.001)). Regression analysis produced a regression equation (R2=0.70) of: Constant Score=99.3-(1.67 times OSS). This level of model fit was statistically significant (F(1,175)=412.8,(p< 0.001))

Conclusion: This study provides information about the behaviour of two frequently used functional scoring systems in patients with proximal humeral fractures. Based on our finding we feel that these scores are appropriate assessment tools in these patients. The OSS may also be considered as an alternative for assessing longer term follow up as, being solely subjective, it is easier to administer and correlates well with the Constant Score.


Bone & Joint Open
Vol. 3, Issue 10 | Pages 786 - 794
12 Oct 2022
Harrison CJ Plummer OR Dawson J Jenkinson C Hunt A Rodrigues JN

Aims. The aim of this study was to develop and evaluate machine-learning-based computerized adaptive tests (CATs) for the Oxford Hip Score (OHS), Oxford Knee Score (OKS), Oxford Shoulder Score (OSS), and the Oxford Elbow Score (OES) and its subscales. Methods. We developed CAT algorithms for the OHS, OKS, OSS, overall OES, and each of the OES subscales, using responses to the full-length questionnaires and a machine-learning technique called regression tree learning. The algorithms were evaluated through a series of simulation studies, in which they aimed to predict respondents’ full-length questionnaire scores from only a selection of their item responses. In each case, the total number of items used by the CAT algorithm was recorded and CAT scores were compared to full-length questionnaire scores by mean, SD, score distribution plots, Pearson’s correlation coefficient, intraclass correlation (ICC), and the Bland-Altman method. Differences between CAT scores and full-length questionnaire scores were contextualized through comparison to the instruments’ minimal clinically important difference (MCID). Results. The CAT algorithms accurately estimated 12-item questionnaire scores from between four and nine items. Scores followed a very similar distribution between CAT and full-length assessments, with the mean score difference ranging from 0.03 to 0.26 out of 48 points. Pearson’s correlation coefficient and ICC were 0.98 for each 12-item scale and 0.95 or higher for the OES subscales. In over 95% of cases, a patient’s CAT score was within five points of the full-length questionnaire score for each 12-item questionnaire. Conclusion. Oxford Hip Score, Oxford Knee Score, Oxford Shoulder Score, and Oxford Elbow Score (including separate subscale scores) CATs all markedly reduce the burden of items to be completed without sacrificing score accuracy. Cite this article: Bone Jt Open 2022;3(10):786–794


Bone & Joint Open
Vol. 4, Issue 2 | Pages 96 - 103
14 Feb 2023
Knowlson CN Brealey S Keding A Torgerson D Rangan A

Aims. Early large treatment effects can arise in small studies, which lessen as more data accumulate. This study aimed to retrospectively examine whether early treatment effects occurred for two multicentre orthopaedic randomized controlled trials (RCTs) and explore biases related to this. Methods. Included RCTs were ProFHER (PROximal Fracture of the Humerus: Evaluation by Randomisation), a two-arm study of surgery versus non-surgical treatment for proximal humerus fractures, and UK FROST (United Kingdom Frozen Shoulder Trial), a three-arm study of two surgical and one non-surgical treatment for frozen shoulder. To determine whether early treatment effects were present, the primary outcome of Oxford Shoulder Score (OSS) was compared on forest plots for: the chief investigator’s (CI) site to the remaining sites, the first five sites opened to the other sites, and patients grouped in quintiles by randomization date. Potential for bias was assessed by comparing mean age and proportion of patients with indicators of poor outcome between included and excluded/non-consenting participants. Results. No bias in treatment effect was observed overall for the CI site, or the first five sites, compared with the remaining sites in either trial. An early treatment effect on the OSS was observed for the first quintile of participants recruited to ProFHER only (clinically relevant difference of seven points). Selection bias for age was observed in the ProFHER trial only, with slightly younger patients being recruited into the study. Both trials showed some selection bias for markers of poor prognosis, although these did not appear to change over time. Conclusion. No bias in treatment effects overall were found at the CI or early sites set-up. An early treatment effect was found in one of the two trials, which was likely a chance effect as this did not continue during the study. Selection bias was observed in both RCTs, however this was minimal and did not impact on outcome. Cite this article: Bone Jt Open 2023;4(2):96–103


Bone & Joint Research
Vol. 13, Issue 8 | Pages 392 - 400
5 Aug 2024
Barakat A Evans J Gibbons C Singh HP

Aims. The Oxford Shoulder Score (OSS) is a 12-item measure commonly used for the assessment of shoulder surgeries. This study explores whether computerized adaptive testing (CAT) provides a shortened, individually tailored questionnaire while maintaining test accuracy. Methods. A total of 16,238 preoperative OSS were available in the National Joint Registry (NJR) for England, Wales, Northern Ireland, the Isle of Man, and the States of Guernsey dataset (April 2012 to April 2022). Prior to CAT, the foundational item response theory (IRT) assumptions of unidimensionality, monotonicity, and local independence were established. CAT compared sequential item selection with stopping criteria set at standard error (SE) < 0.32 and SE < 0.45 (equivalent to reliability coefficients of 0.90 and 0.80) to full-length patient-reported outcome measure (PROM) precision. Results. Confirmatory factor analysis (CFA) for unidimensionality exhibited satisfactory fit with root mean square standardized residual (RSMSR) of 0.06 (cut-off ≤ 0.08) but not with comparative fit index (CFI) of 0.85 or Tucker-Lewis index (TLI) of 0.82 (cut-off > 0.90). Monotonicity, measured by H value, yielded 0.482, signifying good monotonic trends. Local independence was generally met, with Yen’s Q3 statistic > 0.2 for most items. The median item count for completing the CAT simulation with a SE of 0.32 was 3 (IQR 3 to 12), while for a SE of 0.45 it was 2 (IQR 2 to 6). This constituted only 25% and 16%, respectively, when compared to the 12-item full-length questionnaire. Conclusion. Calibrating IRT for the OSS has resulted in the development of an efficient and shortened CAT while maintaining accuracy and reliability. Through the reduction of redundant items and implementation of a standardized measurement scale, our study highlights a promising approach to alleviate time burden and potentially enhance compliance with these widely used outcome measures. Cite this article: Bone Joint Res 2024;13(8):392–400


Bone & Joint Open
Vol. 5, Issue 9 | Pages 729 - 735
3 Sep 2024
Charalambous CP Hirst JT Kwaees T Lane S Taylor C Solanki N Maley A Taylor R Howell L Nyangoma S Martin FL Khan M Choudhry MN Shetty V Malik RA

Aims. Steroid injections are used for subacromial pain syndrome and can be administered via the anterolateral or posterior approach to the subacromial space. It is not currently known which approach is superior in terms of improving clinical symptoms and function. This is the protocol for a randomized controlled trial (RCT) to compare the clinical effectiveness of a steroid injection given via the anterolateral or the posterior approach to the subacromial space. Methods. The Subacromial Approach Injection Trial (SAInT) study is a single-centre, parallel, two-arm RCT. Participants will be allocated on a 1:1 basis to a subacromial steroid injection via either the anterolateral or the posterior approach to the subacromial space. Participants in both trial arms will then receive physiotherapy as standard of care for subacromial pain syndrome. The primary analysis will compare the change in Oxford Shoulder Score (OSS) at three months after injection. Secondary outcomes include the change in OSS at six and 12 months, as well as the Pain Numeric Rating Scale (0 = no pain, 10 = worst pain), Disabilities of Arm, Shoulder and Hand questionnaire (DASH), and 36-Item Short-Form Health Survey (SF-36) (RAND) at three months, six months, and one year after injection. Assessment of pain experienced during the injection will also be determined. A minimum of 86 patients will be recruited to obtain an 80% power to detect a minimally important difference of six points on the OSS change between the groups at three months after injection. Conclusion. The results of this trial will demonstrate if there is a difference in shoulder pain and function after a subacromial space steroid injection between the anterolateral versus posterior approach in patients with subacromial pain syndrome. This will help to guide treatment for patients with subacromial pain syndrome. Cite this article: Bone Jt Open 2024;5(9):729–735


The Bone & Joint Journal
Vol. 104-B, Issue 1 | Pages 157 - 167
1 Jan 2022
Makaram NS Goudie EB Robinson CM

Aims. Open reduction and plate fixation (ORPF) for displaced proximal humerus fractures can achieve reliably good long-term outcomes. However, a minority of patients have persistent pain and stiffness after surgery and may benefit from open arthrolysis, subacromial decompression, and removal of metalwork (ADROM). The long-term results of ADROM remain unknown; we aimed to assess outcomes of patients undergoing this procedure for stiffness following ORPF, and assess predictors of poor outcome. Methods. Between 1998 and 2018, 424 consecutive patients were treated with primary ORPF for proximal humerus fracture. ADROM was offered to symptomatic patients with a healed fracture at six months postoperatively. Patients were followed up retrospectively with demographic data, fracture characteristics, and complications recorded. Active range of motion (aROM), Oxford Shoulder Score (OSS), and EuroQol five-dimension three-level questionnaire (EQ-5D-3L) were recorded preoperatively and postoperatively. Results. A total of 138 patients underwent ADROM; 111 patients were available for long-term follow-up at a mean of 10.9 years (range 1 to 20). Mean age was 50.8 years (18 to 75);79 (57.2%) were female. Mean time from primary ORPF to ADROM was 11.9 months (6 to 19). Five patients developed superficial wound infection; ten developed symptomatic osteonecrosis/post-traumatic arthrosis (ON/PTA); four underwent revision arthrolysis. Median OSS improved from 17 (interquartile range (IQR) 12.0 to 22.0) preoperatively to 40.0 (IQR 31.5 to 48.0) postoperatively, and 39.0 (IQR 31.5 to 46.5) at long-term follow-up (p < 0.001). Median EQ-5D-3L improved from 0.079 (IQR -0.057 to 0.215) to 0.691 (IQR 0.441 to 0.941) postoperatively, and 0.701 (IQR 0.570 to 0.832) at long-term follow-up (p < 0.001). We found that aROM improved in all planes (p < 0.001). Among the variables assessed on multivariable analysis, a manual occupation, worsening Charlson Comorbidity Index and increasing socioeconomic deprivation were most consistently predictive of worse patient-reported outcome scores. Patients who subsequently developed ON/PTA reported significantly worse one-year and late OSS. Conclusion. ADROM in patients with persistent symptomatic stiffness following ORPF can achieve excellent short- and long-term outcomes. More deprived patients, those in a manual occupation, and those with worsening comorbidities have worse outcomes following ADROM. Cite this article: Bone Joint J 2022;104-B(1):157–167


The Bone & Joint Journal
Vol. 104-B, Issue 1 | Pages 83 - 90
1 Jan 2022
Batten TJ Gallacher S Evans JP Harding RJ Kitson J Smith CD Thomas WJ

Aims. The use and variety of stemless humeral components in anatomical total shoulder arthroplasty (TSA) have proliferated since their advent in 2004. Early outcomes are reassuring but independent mid-term results are scarce. This independent study reports a consecutive series of 143 Eclipse stemless shoulder prostheses with a minimum five-year (5 to 10) follow-up. Methods. Outcomes of 143 procedures undertaken for all indications in 131 patients were reviewed, with subset analysis of those for osteoarthritis (OA) (n = 99). The primary outcome was the Oxford Shoulder Score (OSS) at a minimum of five years. Secondary outcomes were ranges of motion and radiological analysis of humeral radiolucency, rotator cuff failure, and glenoid loosening. Results. Mean OSS at mean follow-up of 6.67 years (5.0 to 10.74) was 40.12 (9 to 48), with no statistically significant difference between those implanted for a non-OA indication and those for OA (p = 0.056) or time-dependent deterioration between two years and five years (p = 0.206). Ranges of motion significantly improved compared with preoperative findings and were maintained between two and five years with a mean external rotation of 38° (SD 18.1, 0 to 100) and forward elevation of 152° (SD 29.9, 90 to 180). Of those components with radiographs suitable for analysis (n = 83), 23 (28%) were found to have a least one humeral radiolucent line, which were predominantly incomplete, less than 2 mm, and in a single anatomical zone. No humeral components were loose. A radiolucent line was present around 22 (15%) of glenoid components, and 15 (10%) of components had failed. Rotator cuff failure was found in 21 (15%) components. The mean time to either glenoid or rotator cuff failure was greater than three years following implantation. Survivorship was 96.4% (95% CI 91.6 to 98.5, number at risk 128) at five years, and 94.3% (95% CI 88.2 to 97.3, number at risk 76) at seven years, both of which compare favourably with best results taken from available registries. Conclusion. Functional and radiological outcomes of the Eclipse stemless TSA are excellent, with no loose humeral components at minimum five-year follow-up. The presence of radiolucent lines is of interest and requires long-term observation but does not impact on the clinical results. Of the eight revisions required, this was predominantly for glenoid and rotator cuff failure. Cite this article: Bone Joint J 2022;104-B(1):83–90


The Bone & Joint Journal
Vol. 102-B, Issue 1 | Pages 33 - 41
1 Jan 2020
Norman JG Brealey S Keding A Torgerson D Rangan A

Aims

The aim of this study was to explore whether time to surgery affects functional outcome in displaced proximal humeral fractures

Methods

A total of 250 patients presenting within three weeks of sustaining a displaced proximal humeral fracture involving the surgical neck were recruited at 32 acute NHS hospitals in the United Kingdom between September 2008 and April 2011. Of the 125 participants, 109 received surgery (fracture fixation or humeral head replacement) as per randomization. Data were included for 101 and 67 participants at six-month and five-year follow-up, respectively. Oxford Shoulder Scores (OSS) collected at six, 12, and 24 months and at three, four, and five years following randomization was plotted against time to surgery. Long-term recovery was explored by plotting six-month scores against five-year scores and agreement was illustrated with a Bland-Altman plot.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_1 | Pages 14 - 14
1 Jan 2022
Chotai N Green D Zurgani A Boardman D Baring T
Full Access

Abstract. Aim. The aim of this study was to present the results of treatment of displaced lateral clavicle fractures by an arthroscopically inserted tightrope device (‘Dogbone’, Arthrex). Methods. We performed a retrospective series of our patients treated with this technique between 2015 and 2019. Patients were identified using the ‘CRS Millennium’ software package and operation notes/clinic letters were analysed. We performed an Oxford Shoulder Score (OSS) on all the patients at final follow-up. Our electronic ‘PACS’ system was used to evaluate union in the post-operative radiographs. Results. We treated 26 patients with displaced lateral clavicle fractures between 2015 and 2019. There were 4 patients who were treated with a ‘dogbone’ and supplementary plate fixation and the remaining 22 were treated with a ‘dogbone’ alone. Radiological union was seen in 22 (84%) patients. The mean Oxford Shoulder Score (OSS) was 46. Apart from one patient who required removal of the superior endobutton and knot under local anaesthetic there was no other secondary surgery. There were no cases of infection, nerve injury or frozen shoulder. Conclusions. Arthroscopic ‘dogbone’ treatment of lateral clavicle fractures is a safe, cosmetically friendly technique with promising high rates of fracture union and return to normal function. We recommend its use over the more conventional treatment of a hook plate


Bone & Joint Open
Vol. 4, Issue 3 | Pages 205 - 209
16 Mar 2023
Jump CM Mati W Maley A Taylor R Gratrix K Blundell C Lane S Solanki N Khan M Choudhry M Shetty V Malik RA Charalambous CP

Aims. Frozen shoulder is a common, painful condition that results in impairment of function. Corticosteroid injections are commonly used for frozen shoulder and can be given as glenohumeral joint (GHJ) injection or suprascapular nerve block (SSNB). Both injection types have been shown to significantly improve shoulder pain and range of motion. It is not currently known which is superior in terms of relieving patients’ symptoms. This is the protocol for a randomized clinical trial to investigate the clinical effectiveness of corticosteroid injection given as either a GHJ injection or SSNB. Methods. The Therapeutic Injections For Frozen Shoulder (TIFFS) study is a single centre, parallel, two-arm, randomized clinical trial. Participants will be allocated on a 1:1 basis to either a GHJ corticosteroid injection or SSNB. Participants in both trial arms will then receive physiotherapy as normal for frozen shoulder. The primary analysis will compare the Oxford Shoulder Score (OSS) at three months after injection. Secondary outcomes include OSS at six and 12 months, range of shoulder movement at three months, and Numeric Pain Rating Scale, abbreviated Disabilities of Arm, Shoulder and Hand score, and EuroQol five-level five-dimension health index at three months, six months, and one year after injection. A minimum of 40 patients will be recruited to obtain 80% power to detect a minimally important difference of ten points on the OSS between the groups at three months after injection. The study is registered under ClinicalTrials.gov with the identifier NCT04965376. Conclusion. The results of this trial will demonstrate if there is a difference in shoulder pain and function after GHJ injection or SSNB in patients with frozen shoulder. This will help provide effective treatment to patients with frozen shoulder. Cite this article: Bone Jt Open 2023;4(3):205–209


The Bone & Joint Journal
Vol. 105-B, Issue 8 | Pages 912 - 919
1 Aug 2023
Cunningham LJ Walton M Bale S Trail IA

Aims. Reverse total shoulder arthroplasty (rTSA) can be used in complex cases when the glenoid requires reconstruction. In this study, a baseplate with composite bone autograft and a central trabecular titanium peg was implanted, and its migration was assessed for two years postoperatively using radiostereometric analysis (RSA). Methods. A total of 14 patients who underwent a rTSA with an autograft consented to participate. Of these, 11 had a primary rTSA using humeral head autograft and three had a revision rTSA with autograft harvested from the iliac crest. The mean age of the patients was 66 years (39 to 81). Tantalum beads were implanted in the scapula around the glenoid. RSA imaging (stereographic radiographs) was undertaken immediately postoperatively and at three, six, 12, and 24 months. Analysis was completed using model-based RSA software. Outcomes were collected preoperatively and at two years postoperatively, including the Oxford Shoulder Score, the American Shoulder and Elbow Score, and a visual analogue score for pain. A Constant score was also obtained for the assessment of strength and range of motion. Results. RSA analysis showed a small increase in all translation and rotational values up to six months postoperatively, consistent with settling of the implant. The mean values plateaued by 12 months, with no evidence of further migration. In four patients, there was significant variation outside the mean, which corresponded to postoperative complications. There was a significant improvement in the clinical and patient-reported outcomes from the preoperative values to those at two years postoperatively (p < 0.001). Conclusion. These findings show, using RSA, that a glenoid baseplate composite of a trabecular titanium peg with autograft stabilizes within the glenoid about 12 months after surgery, and reinforce findings from a previous study of this implant/graft with CT scans at two years postoperatively, indicating that this type of structural composite results in sound early fixation. Cite this article: Bone Joint J 2023;105-B(8):912–919


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 1 | Pages 119 - 123
1 Jan 2009
Benson RT McDonnell SM Rees JL Athanasou NA Carr AJ

We assessed the predictive value of the macroscopic and detailed microscopic appearance of the coracoacromial ligament, subacromial bursa and rotator-cuff tendon in 20 patients undergoing subacromial decompression for impingement in the absence of full-thickness tears of the rotator cuff. Histologically, all specimens had features of degenerative change and oedema in the extracellular matrix. Inflammatory cells were seen, but there was no evidence of chronic inflammation. However, the outcome was not related to cell counts. At three months the mean Oxford shoulder score had improved from 29.2 (20 to 40) to 39.4 (28 to 48) (p < 0.0001) and at six months to 45.5 (36 to 48) (p < 0.0001). At six months, although all patients had improved, the seven patients with a hooked acromion had done so to a less extent than those with a flat or curved acromion judged by their mean Oxford shoulder scores of 43.5 and 46.5 respectively (p = 0.046). All five patients with partial-thickness tears were within this group and demonstrated less improvement than the patients with no tear (mean Oxford shoulder scores 43.2 and 46.4, respectively, p = 0.04). These findings imply that in the presence of a partial-thickness tear subacromial decompression may require additional specific treatment to the rotator cuff if the outcome is to be improved further


The Bone & Joint Journal
Vol. 104-B, Issue 1 | Pages 76 - 82
1 Jan 2022
ten Brinke B Hesseling B Eygendaal D Hoelen MA Mathijssen NMC

Aims. Stemless humeral implants have been developed to overcome stem-related complications in total shoulder arthroplasty (TSA). However, stemless implant designs may hypothetically result in less stable initial fixation, potentially affecting long-term survival. The aim of this study is to investigate early fixation and migration patterns of the stemless humeral component of the Simpliciti Shoulder System and to evaluate clinical outcomes. Methods. In this prospective cohort study, radiostereometric analysis (RSA) radiographs were obtained in 24 patients at one day, six weeks, six months, one year, and two years postoperatively. Migration was calculated using model-based RSA. Clinical outcomes were evaluated using the visual analogue scale (VAS), the Oxford Shoulder Score (OSS), the Constant-Murley Score (CMS), and the Disabilities of the Arm, Shoulder and Hand (DASH) score. Results. At two years, median translation along the x-, y-, and z-axis was -0.12 mm (interquartile range (IQR) -0.18 to 0.02), -0.17 mm (IQR -0.27 to -0.09), and 0.09 mm (IQR 0.02 to 0.31). Median rotation around the x-, y-, and z-axis was 0.12° (IQR -0.50 to 0.57), -0.98° (IQR -1.83 to 1.23), and 0.09° (IQR -0.76 to 0.30). Overall, 20 prostheses stabilized within 12 months postoperatively. Four prostheses showed continuous migration between 12 and 24 months. At two-year follow-up, with the exception of one revised prosthesis, all clinical scores improved significantly (median VAS difference at rest: -3.0 (IQR -1.5 to -6.0); OSS 22.0 (IQR 15.0 to 25.0); CMS 29.5 (IQR 15.0 to 35.75); and DASH -30.0 (IQR -20.6 to -41.67) (all p < 0.001)) with the exception of one revised prosthesis. Conclusion. In conclusion, we found that 20 out of 24 implants stabilized within 12 months postoperatively. The significance of continuous migration in four implants is unclear and future research on the predictive value of early migration for future loosening in TSA is required. Clinical results revealed a clinically relevant improvement. Cite this article: Bone Joint J 2022;104-B(1):76–82


The Bone & Joint Journal
Vol. 104-B, Issue 1 | Pages 91 - 96
1 Jan 2022
Modi A Haque A Deore V Singh HP Pandey R

Aims. Long-term outcomes following the use of human dermal allografts in the treatment of symptomatic irreparable rotator cuff tears are not known. The aim of this study was to evaluate these outcomes, and to investigate whether this would be a good form of treatment in young patients in whom a reverse shoulder arthroplasty should ideally be avoided. Methods. This prospective study included 47 shoulders in 45 patients who underwent an open reconstruction of the rotator cuff using an interposition GraftJacket allograft to bridge irreparable cuff tears, between January 2007 and November 2011. The Oxford Shoulder Score (OSS), pain score, and range of motion (ROM) were recorded preoperatively and at one year and a mean of 9.1 years (7.0 to 12.5) postoperatively. Results. There was significant improvement in the mean OSS from 24.7 (SD 5.4) preoperatively to 42.0 (SD 6.3) at one year, and this improvement was maintained at 9.1 years (p < 0.001), with a score of 42.8 (SD 6.8). Similar significant improvements in the pain score were seen and maintained at the final follow-up from 6.1 (SD 1.6) to 2.1 (SD 2.3) (p < 0.001). There were also significant improvements in the ROM of the shoulder, and patient satisfaction was high. Conclusion. The use of an interposition human dermal allograft in patients with an irreparable rotator cuff tear leads to good outcomes that are maintained at a mean of nine years postoperatively. Cite this article: Bone Joint J 2022;104-B(1):91–96


The Bone & Joint Journal
Vol. 103-B, Issue 8 | Pages 1333 - 1338
2 Aug 2021
Kankanalu P Borton ZM Morgan ML Cresswell T Espag MP Tambe AA Clark DI

Aims. Reverse total shoulder arthroplasty (RTSA) using trabecular metal (TM)-backed glenoid implants has been introduced with the aim to increase implant survival. Only short-term reports on the outcomes of TM-RTSA have been published to date. We aim to present the seven-year survival of TM-backed glenoid implants along with minimum five-year clinical and radiological outcomes. Methods. All consecutive elective RTSAs performed at a single centre between November 2008 and October 2014 were reviewed. Patients who had primary TM-RTSA for rotator cuff arthropathy and osteoarthritis with deficient cuff were included. A total of 190 shoulders in 168 patients (41 male, 127 female) were identified for inclusion at a mean of 7.27 years (SD 1.4) from surgery. The primary outcome was survival of the implant with all-cause revision and aseptic glenoid loosening as endpoints. Secondary outcomes were clinical, radiological, and patient-related outcomes with a five-year minimum follow-up. Results. The implant was revised in ten shoulders (5.2%) with a median time to revision of 21.2 months (interquartile range (IQR) 9.9 to 41.8). The Kaplan-Meier survivorship estimate at seven years was 95.9% (95% confidence interval (CI) 91.7 to 98; 35 RTSAs at risk) for aseptic mechanical failure of the glenoid and 94.8% (95% CI 77.5 to 96.3; 35 RTSAs at risk) for all-cause revision. Minimum five-year clinical and radiological outcomes were available for 103 and 98 RTSAs respectively with a median follow-up time of six years (IQR 5.2 to 7.0). Median postoperative Oxford Shoulder Score was 38 (IQR 31 to 45); median Constant and Murley score was 60 (IQR 47.5 to 70); median forward flexion 115° (IQR 100° to 125°); median abduction 95° (IQR 80° to 120°); and external rotation 25° (IQR 15° to 40°) Scapular notching was seen in 62 RTSAs (63.2%). Conclusion. We present the largest and longest-term series of TM-backed glenoid implants demonstrating 94.8% all-cause survivorship at seven years. Specifically pertaining to glenoid loosening, survival of the implant increased to 95.9%. In addition, we report satisfactory minimum five-year clinical and radiological outcomes. Cite this article: Bone Joint J 2021;103-B(8):1333–1338


Bone & Joint Open
Vol. 2, Issue 1 | Pages 58 - 65
22 Jan 2021
Karssiens TJ Gill JR Sunil Kumar KH Sjolin SU

Aims. The Mathys Affinis Short is the most frequently used stemless total shoulder prosthesis in the UK. The purpose of this prospective cohort study is to report the survivorship, clinical, and radiological outcomes of the first independent series of the Affinis Short prosthesis. Methods. From January 2011 to January 2019, a total of 141 Affinis Short prostheses were implanted in 127 patients by a single surgeon. Mean age at time of surgery was 68 (44 to 89). Minimum one year and maximum eight year follow-up (mean 3.7 years) was analyzed using the Oxford Shoulder Score (OSS) at latest follow-up. Kaplan-Meier survivorship analysis was performed with implant revision as the endpoint. Most recently performed radiographs were reviewed for component radiolucent lines (RLLs) and proximal humeral migration. Results. Five shoulders underwent revision surgery (3.5%); three for rotator cuff failure, one for infection, and one for component malposition. Survivorship of the implant was 95.4% (95% confidence interval 90.1% to 97.9%) at five and nine years. Mean OSS improved significantly compared to preoperative values from 19.0 (1 to 35) to 43.3 (7 to 48) (p < 0.001). Radiological analysis was undertaken for 99 shoulders. This revealed humeral RLLs in one case (1%), glenoid RLLs in 15 cases (15.2%), and radiological rotator cuff failure in 22 cases (22.2%). Conclusion. This prospective cohort study shows encouraging short- to mid-term survivorship and clinical and radiological results for the Mathys Affinis Short, Short Stem Total Shoulder Prosthesis. Level of Evidence: IV. Cite this article: Bone Jt Open 2021;2(1):58–65


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_11 | Pages 8 - 8
1 Nov 2022
Bharmal A Gokhale N Curtis S Prasad G Bidwai A Kurian J
Full Access

Abstract. Background. To determine the long-term survival outcomes of Copeland Resurfacing Hemiarthroplasty (CRHA) performed by a single surgeon series. Methods. A retrospective cohort study which looked at patients who underwent CRHA over 6 years. Re-operations including revisions with component exchange taking place in our hospital and at local centres were reviewed. Oxford Shoulder Score (OSS) was used to assess their functional outcomes pre- and post-CRHA. Results. 80 CRHAs were performed in 72 patients between 2007 and 2013 with a mean follow-up of 6.5 years. The mean follow-up was 79 months (50–122). The primary indication for CRHA was osteoarthritis (76.3%), cuff tear arthropathy (16.3%), rheumatoid arthritis (5%) and post-trauma (1.3%). The mean pre-operative OSS was 16, which doubled following CRHA surgery. Fifteen patients underwent revision surgery due to ongoing glenoid pain with a mean revision time following primary CRHA being 49 months. Projected survival at the endpoints 5,7 and 10 years were 83, 81 and 79% respectively. Conclusion. This study provides us with a much longer average follow-up period in comparison to many other studies published. Previous studies, support resurfacing as a useful implant in reducing pain and improving function in the short-term; but this series demonstrates over the medium-term a relatively high revision rate of about 20% in comparison with other arthroplasty options, despite the revision rate seeming to plateau from the 5-year mark onwards


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 70 - 70
10 Feb 2023
Cosic F Kirzner N Edwards E Page R Kimmel L Gabbe B
Full Access

Proximal humerus fracture dislocations are amongst the most severe proximal humerus injuries, presenting a challenging management problem. The aim of this study was to report on the long-term outcomes of the management of proximal humerus fracture dislocations. Patients with a proximal humerus fracture dislocation managed at a Level 1 trauma centre from January 2010 to December 2018 were included. Patients with an isolated tuberosity fracture dislocation or a pathological fracture were excluded. Outcome measures were the Oxford Shoulder Score (OSS), EQ-5D-5L, return to work, and radiological outcomes. Complications recorded included further surgery, loss of position/fixation, non-union/malunion, and avascular necrosis. A total of 69 patients were included with a proximal humerus fracture dislocation in the study period; 48 underwent surgical management and 21 were managed with closed reduction alone. The mean (SD) age of the cohort was 59.7 (±20.4), and 54% were male. Overall patients reported a mean OSS of 39.8 (±10.3), a mean EQ-5D utility score of 0.73 (±0.20), and 78% were able to return to work at a median of 1.2 months. There was a high prevalence of complications in both patients managed operatively or with closed reduction (25% and 38% respectively). In patients undergoing surgical management, 21% required subsequent surgery. Patient reported outcome measures post proximal humerus fracture dislocations do not return to normal population levels. These injuries are associated with a high prevalence of complications regardless of management. Appropriate patient counselling should be undertaken before embarking on definitive management


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_4 | Pages 2 - 2
8 Feb 2024
Dixon JE Rankin IA Sciberras N Khan LAK Barker SL Cairns DA Kumar K
Full Access

In recent years, use of anatomic stemless total shoulder arthroplasty (AsTSA) has increased. Despite evidence to suggest good mid-term results at 2-year follow-up there is a paucity of evidence for longer term follow-up. This study aimed to investigate outcomes at a minimum of 5 years post-operatively following primary AsTSA. This study is a retrospective case series of all patients who underwent a Mathys Affinis AsTSA from July 2010 (first case) to August 2018 (to allow minimum 5-year follow-up). Clinical outcomes included revision rate, range of motion and patient reported outcomes (Oxford Shoulder Score and Numerical Satisfaction Score). Radiological outcome was assessment of radiolucent lines for Lazarus grading. A total of 105 stemless TSAs were implanted. Five patients underwent revision (4.8%). Seventy-five AsTSA's were included in the final study for analysis of 5-year outcomes. Median follow-up time was 6.1 years. Median age was 69 years old and 81% were female. Oxford shoulder score showed a range of 18 to 48, with a median score of 47. Satisfied or very Satisfied was selected in 94.37%. Median range of motion assessments showed forward elevation 160°, abduction 150°, external rotation 40°, and mode internal rotation was to the lumbar spine. No glenoid lucency was present in 79.7%. There were 9.5% with Lazarus Grade 1 lucency, 5.4% with Lazarus Grade 2, and 5.4% Lazarus Grade 3. No humeral lucency was observed. This cohort study demonstrates promising clinical and radiological outcomes for the Mathys Affinis Stemless TSA at minimum 5 years post-operatively


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_6 | Pages 9 - 9
20 Mar 2023
Desai T Hoban K Ridley D Jariwala A
Full Access

Sub-acromial decompression surgery (SAD) has been widely used to treat shoulder impingement. Its validity has been questioned in multi-centric clinical trials and dissatisfaction rates can be high (35%). It is difficult to predict which patients will benefit operatively as research into predictive factors is limited. The study aim was to conduct a root-cause analysis of reasons for dissatisfaction in a cohort of operated patients. All patients with SAD dissatisfaction in the local Upper Limb database between 2015-19 (n=74/296) formed our study cohort. Patients were scored on Oxford shoulder score (OSS), QuickDASH score, EQ-5D-3L (TTO+VAS) at weeks 26 and 52 post-operatively. Patients' clinical history, radiographs, consultation and operative notes were reviewed. 28% of patients were dissatisfied with surgery. Mean age =52.3±13.4 years with equal gender distribution. 87% were operated arthroscopically. 67% were in physically demanding occupations. There was a significant increase in OSS and QuickDASH at weeks 26 and 52 post-operatively (p<0.05), similar improvement was not noted in VAS pain score. Pain followed by stiffness were the main contributors of dissatisfaction. Multiple implicating factors were noted, the most common being acromio-clavicular joint arthritis (25.7%), suggesting concomitant pathologies as an additional cause for patient dissatisfaction. This is the first study to evaluate reasons for dissatisfaction following SAD. We noted high rates (28%) of dissatisfaction and a predilection for those involved in physically demanding occupations. We recommend meticulous pre-operative workup to identify co-existing pathologies and appropriate pre-operative counselling to improve outcomes in selected patients needing SAD following failure of conservative management


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 33 - 33
23 Feb 2023
Paltoglou N Page R Gill S
Full Access

In Australia nearly two-thirds of arthroplasty procedures are performed in the private setting, which is disproportionate to the dimensioning 43.5% of the population with private health cover. The rapid growth of shoulder arthroplasty surgery will be absorbed by both private and public sectors. This study aimed to assess the influence of healthcare setting on elective shoulder arthroplasty outcomes, defined by revision rate, and functional measures. Data was collected on all primary procedures performed from 2004 – 2019 within a regional area of Victoria, Australia. Patients were categorised into private or public settings. Trauma cases for acute proximal humerus fractures were excluded. The primary outcome of revision surgery was recorded as a cumulative percentage, and survival analysis conducted to calculate a hazard ratio (HR). Functional outcomes were measured through range-of-motion (ROM) and multiple validated patient-reported-outcome-measures (PROMs). 458 patients were identified in the study: 290 private and 168 public. There was no difference in the revision rate (3.8% private, 4.8% public), with an adjusted HR of 1.25 (p=0.66) for public compared to private. Baseline and post-operative functional measures were significantly greater in the private setting for ROMs and PROMs analysis, in particular post-operative QuickDASH (15.9±14.7 to 32.7±23.5; p<0.001) and Oxford Shoulder Score (42.6±6.3 to 35.7±11.2; p<0.001). However, there was no significant difference for any of the functional measures in the amount of change from baseline to 12-months between settings. Although healthcare setting does not appear to influence revision rate for shoulder arthroplasty, clear differences were demonstrated for functional measures both pre and post operatively. This may be attributed to factors such as access to perioperative rehabilitation and should be an area to target future investigations


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 3 | Pages 367 - 373
1 Mar 2009
Allom R Colegate-Stone T Gee M Ismail M Sinha J

A consecutive series of 372 patients who underwent surgery for disorders of the rotator cuff involving arthroscopic subacromial decompression and open or arthroscopic repairs of the cuff were prospectively investigated as to the comparability of subjective and objective assessment scores of shoulder function. Assessments were made before operation and at 3, 6, 12, 18 and 24 months after surgery using the Disabilities of the Arm, Shoulder, and Hand score, the Oxford shoulder score and the Constant-Murley score, which was used as a reference. All scores were standardised to a scale of 0 to 100 for comparison. Statistical analysis compared the post-operative course and the mean score for the subjective Disabilities to the Arm, Shoulder and Hand score and Oxford shoulder score, with the objective Constant score at each interval. A strong correlation was evident between both subjective scores and the Constant score. We concluded that both the subjective scores would be useful substitutes for the Constant score, obviating the need for a trained investigator and the specialist equipment required to perform the Constant score


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 2 | Pages 201 - 205
1 Feb 2009
Hanusch BC Goodchild L Finn P Rangan A

The aim of this study was to determine the functional outcome and rate of re-tears following mini-open repair of symptomatic large and massive tears of the rotator cuff using a two-row technique. The 24 patients included in the study were assessed prospectively before and at a mean of 27 months (18 to 53) after surgery using the Constant and the Oxford Shoulder scores. Ultrasound examination was carried out at follow-up to determine the integrity of the repair. Patient satisfaction was assessed using a simple questionnaire. The mean Constant score improved significantly from 36 before to 68 after operation (p < 0.0001) and the mean Oxford Shoulder score from 39 to 20 (p < 0.0001). Four of the 24 patients (17%) had a re-tear diagnosed by ultrasound. A total of 21 patients (87.5%) were satisfied with the outcome of their surgery. The repair remained intact in 20 patients (83%). However, the small number of re-tears (four patients) in the study did not allow sufficient analysis to show a difference in outcome in relation to the integrity of the repair


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_15 | Pages 19 - 19
7 Nov 2023
Hackney R Toland G Crosbie G Mackenzi S Clement N Keating J
Full Access

A fracture of the tuberosity is associated with 16% of anterior glenohumeral dislocations. Manipulation of these injuries in the emergency department is safe with less than 1% risk of fracture propagation. However, there is a risk of associated neurological injury, recurrent instability and displacement of the greater tuberosity fragment. The risks and outcomes of these complications have not previously been reported. The purpose of this study was to establish the incidence and outcome of complications associated with this pattern of injury. We reviewed 339 consecutive glenohumeral dislocations with associated greater tuberosity fractures from a prospective trauma database. Documentation and radiographs were studied and the incidence of neurovascular compromise, greater tuberosity fragment migration and intervention and recurrent instability recorded. The mean age was 61 years (range, 18–96) with a female preponderance (140:199 male:female). At presentation 24% (n=78) patients had a nerve injury, with axillary nerve being most common (n=43, 55%). Of those patients with nerve injuries 15 (19%) did not resolve. Greater tuberosity displacement >5mm was observed in 36% (n=123) of patients with 40 undergoing acute surgery, the remainder did not due to comorbidities or patient choice. Persistent displacement after reduction accounted for 60 cases, later displacement within 6 weeks occurred in 63 patients. Recurrent instability occurred in 4 (1%) patients. Patient reported outcomes were poor with average EQ5D being 0.73, QDASH score of 16 and Oxford Shoulder Score of 41. Anterior glenohumeral dislocation with associated greater tuberosity fracture is common with poor long term patient reported outcomes. Our results demonstrate there is a high rate of neurological deficits at presentation with the majority resolving spontaneously. Recurrent instability is rare. Late tuberosity fragment displacement occurs in 18% of patients and regular follow-up for 6 weeks is recommended to detect this


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_8 | Pages 34 - 34
10 May 2024
Penumarthy R Turner P
Full Access

Aim. Clavicular osteotomy was described as an adjunct to deltopectoral approach for improved exposure of the glenohumeral joint. This study aims to present contemporary outcomes and complications associated with the routine use of clavicular osteotomy by a single surgeon in a regional setting within New Zealand. Methods. A retrospective case series of patients who have undergone any shoulder arthroplasty for any indication between March 2017 to August 2022. This time period includes all patients who had clavicular osteotomy(OS) and patients over an equal time period prior to the routine use of osteotomy as a reference group (N-OS). Oxford Shoulder Score (OSS) and a Simple Shoulder Test (STT) were used to assess functional outcomes and were compared with the reported literature. Operative times and Complications were reviewed. Results. 66 patients were included in the study. 33 patients in the OS group and 33 in the N-OS group. No difference in age, sex, indications for operative intervention and the surgery provided was identified. No significant difference in operative time between groups (N-OS 121 minutes; OS 128 minutes). No clinically significant difference was identified in the OSS (N-OS; mean 38 vs OS 39) or the STT (N-OS 8.3 vs OS 9). The outcomes scores of both groups are in keeping with published literature. Two post operative clavicle fractures, one prominent surgical knot occurred in the OS that required further surgical intervention. Two cases of localized pain over the clavicle and one case of the prominent lateral clavicle were reported in the OS group. Two cases of localized pain over clavicle reported in the N-OS group. Conclusion. Use of clavicular osteotomy is not associated with inferior patient reported. The osteotomy introduces specific risks, however, the study provides evidence that these complications are infrequent and avoidable. Surgeons should feel confident in using this adjunct when exposure to the shoulder is difficult


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 71 - 71
10 Feb 2023
Cosic F Kirzner N Edwards E Page R Kimmel L Gabbe B
Full Access

There is very limited literature describing the outcomes of management for proximal humerus fractures with more than 100% displacement of the head and shaft fragments as a separate entity. This study aimed to compare operative and non-operative management of the translated proximal humerus fracture. A prospective cohort study was performed including patients managed at a Level 1 trauma centre between January 2010 to December 2018. Patients with 2, 3 and 4-part fractures were included based on the degree of translation of the shaft fragment (≥100%), resulting in no cortical contact between the head and shaft fragments. Outcome measures were the Oxford Shoulder Score (OSS), EQ-5D-5L, and radiological outcomes. Complications recorded included further surgery, loss of position/fixation, and non-union/malunion. Linear and logistic regression models were used to compare management options. There were 108 patients with a proximal humerus fracture with ≥100% translation; 76 underwent operative management and 32 were managed non-operatively with sling immobilisation. The mean (SD) age in the operative group was 54.3 (±20.2) and in the non-operative group was 73.3 (±15.3) (p<0.001). There was no association between OSS and management options (mean 38.5(±9.5) operative vs mean 41.3 (±8.5) non-operative, p=0.48). Operative management was associated with improved health status outcomes; EQ-5D utility score adjusted mean difference 0.16 (95%CI 0.04-0.27, p=0.008); EQ-5D VAS adjusted mean difference 19.2 (95%CI 5.2-33.2, p=0.008). Operative management was further associated with a lower odds of non-union (adjusted OR 0.30, 95%CI 0.09-0.97, p=0.04), malunion (adjusted OR 0.14, 95%CI 0.04-0.51, p=0.003) and complications (adjusted OR 0.07, 95%CI 0.02-0.32, p=0.001). Translated proximal humerus fractures with ≥100% displacement demonstrate improved health status and radiological outcomes following surgical fixation. Patients with this injury should be considered for operative intervention


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 63 - 63
4 Apr 2023
Rashid M Cunningham L Walton M Monga P Bale S Trail I
Full Access

The purpose of this study is to report the clinical and radiological outcomes of patients undergoing primary or revision reverse total shoulder arthroplasty using custom 3D printed components to manage severe glenoid bone loss with a minimum of 2-year follow-up. After ethical approval (reference: 17/YH/0318), patients were identified and invited to participate in this observational study. Inclusion criteria included: 1) severe glenoid bone loss necessitating the need for custom implants; 2) patients with definitive glenoid and humeral components implanted more than 2 years prior; 3) ability to comply with patient reported outcome questionnaires. After seeking consent, included patients underwent clinical assessment utilising the Oxford Shoulder Score (OSS), Constant-Murley score, American Shoulder and Elbow Society Score (ASES), and quick Disabilities of the Arm, Shoulder, and Hand Score (quickDASH). Radiographic assessment included AP and axial projections. Patients were invited to attend a CT scan to confirm osseointegration. Statistical analysis utilised included descriptive statistics (mean and standard deviation) and paired t test for parametric data. 3 patients had revision surgery prior to the 2-year follow-up. Of these, 2/3 retained their custom glenoid components. 4 patients declined to participate. 5 patients were deceased at the time of commencement of the study. 21 patients were included in this analysis. The mean follow-up was 36.1 months from surgery (range 22–60.2 months). OSS improved from a mean 16 (SD 9.1) to 36 (SD 11.5) (p < 0.001). Constant-Murley score improved from mean 9 (SD 9.2) to 50 (SD 16.4) (p < 0.001). QuickDASH improved from mean 67 (SD 24) to 26 (SD 27.2) (p = 0.004). ASES improved from mean 28 (SD 24.8) to 70 (SD 23.9) (p = 0.007). Radiographic evaluation demonstrated good osseointegration in all 21 included patients. The utility of custom 3D-printed components for managing severe glenoid bone loss in primary and revision reverse total shoulder arthroplasty yields significant clinical improvements in this complex patient cohort


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_16 | Pages 50 - 50
1 Dec 2021
Mehta S Mahajan U Sathyamoorthy P
Full Access

Abstract. Background. The influence of diagnosis on outcomes after reverse shoulder arthroplasty (RSA) is not completely understood. The purpose of this study was to compare clinical outcomes of different pathologies. Methods. A total of 78 RSAs were performed for the following diagnoses: (1) rotator cuff tear arthropathy(RCA), (2) massive cuff tear(MCT) with osteoarthritis(OA), (3) MCT without OA, (4) arthritis, (5) acute proximal humerus fracture. Mean follow up 36 months (upto 5 years) Range of motion, Oxford Shoulder Score were obtained preoperatively and postoperatively. Results. Mean OSS was 30. The RCA, MCT-with-OA, MCT-without-OA, and arthritis groups all exhibited significant improvements in all outcome scores and in all planes of motion. After adjustment for age and compared with RCA, those with OA had significantly better abduction (P < .05), and those with fractures had significantly worse patient satisfaction (P < .05). Among male patients, those with MCTs without OA had significantly worse satisfaction (P < .05). Conclusion. RSA reliably provides improvement regardless of preoperative diagnosis. Although subtle differences exist between male and female patients, improvements in clinical outcome scores were apparent after RSA


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_20 | Pages 18 - 18
1 Apr 2013
Wronka KS Sinha A
Full Access

The Delta total shoulder replacement is a reversed, semi-constrained prosthesis and is recommended for the management of rotator cuff arthropathy and other difficult reconstructive shoulder problems. It was initially advised to use this prosthesis in patients older than 75. There were reports saying the complication rates of this prosthesis are high and patients' satisfaction and functional outcome is far from being satisfactory. In our study we wanted to evaluate results and complications of reverse shoulder arthroplasty in practice of single surgeon. In our study we reviewed patients who had reverse shoulder arthroplasty performed between 2001 and 2009. We evaluated them clinically and radiologically. We measured functional outcome using Constant score, we used Oxford Shoulder score to measure patients' subjective outcome. We compared our results to pre-operative Oxford Shoulder score (unfortunately no pre-op constant score was done). X-rays were assessed by independent surgeon who was not involved in care of the patients. Out of 36 reverse shoulder replacements performed by Mr. Sinha from 2001 to 2009 we managed to review in clinic 29 shoulders. 3 patients died from causes not related to surgery, 3 patients were too unwell to attend clinic, we lost 1 patient to follow up. Mean time from operation to follow up was 33 months (range 6 to 82 months). Average patients' age at time of surgery was 73,4 years (range: 44 to 90). Indications included rotator cuff arthropathy (86%), other indications were trauma (10%) and revision of failed hemiarthroplasty (4%). There were neither revisions nor infections in our group. There was 1 dislocation that occurred after operation, this was reduced under GA and never re-dislocated again. 12 patients (41%) were very pleased with result of surgery, 15 patients (52%) were satisfied and 2 patients said surgery did not meet their expectations. Mean Shoulder Oxford score improved from 20.8 (range 2 to 36) pre-operatively to 36.7 (range 20 to 48) during follow up. 3 patients had Oxford Shoulder score of 48 (maximum). Oxford shoulder score deteriorated in 2 cases (one in case when replacement was done to treat fracture). Post operative Constant score was 65.5. All patients but one declared overall improvement. 10 patients (34%) reported no pain at all. 5 patients who were 65 years old or younger at time of surgery did well and improved their shoulder function. In our experience reverse geometry shoulder replacement is a very good solution for rotator cuff arthropathy. Results in proximal humeral fracture are worse, but the number of patients we had was small and our experience is limited. Mid term results are very satisfactory overall, even in younger and more demanding patients. The complications were rare and overall patients' satisfaction very high. We think more research needs to be done to asses long term results, especially in younger population


The Bone & Joint Journal
Vol. 101-B, Issue 7 | Pages 860 - 866
1 Jul 2019
Nicholson JA Searle HKC MacDonald D McBirnie J

Aims. The aim of this study was to investigate the influence of age on the cost-effectiveness of arthroscopic rotator cuff repair. Patients and Methods. A total of 112 patients were prospectively monitored for two years after arthroscopic rotator cuff repair using the Disabilities of the Arm, Shoulder and Hand questionnaire (DASH), the Oxford Shoulder Score (OSS), and the EuroQol five-dimension questionnaire (EQ-5D). Complications and use of healthcare resources were recorded. The incremental cost-effectiveness ratio (ICER) was used to express the cost per quality-adjusted life-year (QALY). Propensity score-matching was used to compare those aged below and above 65 years of age. Satisfaction was determined using the Net Promoter Score (NPS). Linear regression was used to identify variables that influenced the outcome at two years postoperatively. Results. A total of 92 patients (82.1%) completed the follow-up. Their mean age was 59.5 years (. sd. 9.7, 41 to 78). There were significant improvements in the mean DASH (preoperative 47.6 vs one-year 15.3; p < 0.001) and OSS scores (26.5 vs 40.5; p < 0.001). Functional improvements were maintained with no significant change between one and two years postoperatively. The mean preoperative EQ-5D was 0.54 increasing to 0.81 at one year (p < 0.001) and maintained at 0.86, two years postoperatively. There was no significant difference between those aged below or above 65 years of age with regards to postoperative shoulder function or EQ-5D gains. Smoking was the only characteristic that significantly adversely influenced the EQ-5D at two years postoperatively (p = 0.005). A total of 87 were promoters and five were passive, giving a mean NPS of 95 (87/92). The total mean cost per patient was £3646.94 and the mean EQ-5D difference at one year was 0.2691, giving a mean ICER of £13 552.36/QALY. At two years, this decreased further to £5694.78/QALY. This was comparable for those aged below or above 65 years of age (£5209.91 vs £5525.67). Smokers had an ICER that was four times more expensive. Conclusion. Arthroscopic rotator cuff repair results in excellent patient satisfaction and cost-effectiveness, regardless of age. Cite this article: Bone Joint J 2019;101-B:860–866


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_16 | Pages 72 - 72
1 Dec 2021
Komperla S Giles W Flatt E Gandhi MJ Eyre-Brook AE Jones V Papanna M Eves T Thyagarajan D
Full Access

Abstract. Shoulder replacements have evolved and current 4th generation implants allow intraoperative flexibility to perform anatomic, reverse, trauma, and revision shoulder arthroplasty. Despite high success rates with shoulder arthroplasty, complication rates high as 10–15% have been reported and progressive glenoid loosening remains a concern. Objectives. To report medium term outcomes following 4th generation VAIOS® shoulder replacement. Methods. We retrospectively analysed prospectively collected data following VAIOS® shoulder arthroplasty performed by the senior author between 2014–2020. This included anatomical (TSR), reverse(rTSR), revision and trauma shoulder replacements. The primary outcome was implant survival (Kaplan-Meier analysis). Secondary outcomes were Oxford Shoulder Scores (OSS), radiological outcomes and complications. Results. 172 patients met our inclusion criteria with 114 rTSR, 38 anatomical TSR, and 20 hemiarthroplasty. Reverse TSR- 55 primary, 31 revision, 28 for trauma. Primary rTSR- 0 revisions, average 3.35-year follow-up. Revision rTSR-1 revision (4.17%), average 3.52-year follow-up. Trauma rTSR- 1 revision (3.57%), average 4.56-year follow-up OSS: Average OSS improved from 15.39 to 33.8 (Primary rTSR) and from 15.11 to 29.1 (Revision rTSR). Trauma rTSR-Average post-operative OSS was 31.4 Anatomical TSR38 patients underwent primary anatomical TSR, 8 were revisions following hemiarthroplasty. In 16/38 patients, glenoid bone loss was addressed by bone grafting before implantation of the metal back glenoid component. Mean age at time of surgery was 68.3 years (53 – 81 years). Mean follow-up was 34 months (12 – 62 months). The average Oxford shoulder score improved from 14 (7–30) to 30 (9–48). There were 3 revisions (7.8%); two following subscapularis failure requiring revision conversion to reverse shoulder replacement and one for glenoid graft failure. Conclusions. The medium-term results of the VAIOS® system suggest much lower revision rates across multiple configurations of the system than previously reported, as well as a low incidence of scapular notching. This system allows conversion to rTSR during primary and revision surgery


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_16 | Pages 71 - 71
1 Dec 2021
Giles W Komperla S Flatt E Gandhi M Eyre-Brook A Jones V Papanna M Eves T Thyagarajan D
Full Access

Abstract. Background/Objectives. The incidence of reverse total shoulder replacement (rTSR) implantation is increasing globally, but apprehension exists regarding complications and associated challenges. We retrospectively analysed the senior author's series of rTSR from a tertiary centre using the VAIOS shoulder system, a modular 4th generation implant. We hypothesised that the revision rTSR cohort would have less favourable outcomes and more complications. Methods. 114 patients underwent rTSR with the VAIOS system, over 7 years. The primary outcome was implant survival. Secondary outcomes were Oxford shoulder scores (OSS), radiographic analysis (scapular notching, tuberosity osteolysis, and periprosthetic radiolucent lines) and complications. Results. There were 55 Primary rTSR, 31 Revision rTSR and 28 Trauma rTSR. Implant survival: Primary rTSR- 0 revisions, average 3.35-year follow-up. Revision rTSR-1 revision (4.17%), average 3.52-year follow-up. Trauma rTSR- 1 revision (3.57%), average 4.56-year follow-up OSS: Average OSS improved from 15.39 to 33.8 (Primary rTSR) and from 15.11 to 29.1 (Revision rTSR). Average post-operative OSS for the Trauma rTSR was 31.4 Radiological analysis and complications: Low incidence of scapular notching One hairline fracture below the tip of stem, noted incidentally, which required no treatment. One periprosthetic fracture after alcohol related fall. Treated non-surgically One joint infection requiring two-stage revision to rTSR. One dislocation noted at 2 year follow up. This patient had undergone nerve grafting within 6 months of rTSR for axillary nerve injury sustained during the original fracture dislocation. One acromial fracture with tibial and distal humeral fracture after a fall. Conclusions. The 4th generation modular VAIOS implant is a reliable option for various indications. The revision rTSR cohort had favourable outcomes with low complication rates. In this series, early-to-medium term results suggest lower revision rates and good functional outcomes when compared to published reports. We plan to monitor long-term implant survivorship and patient reported outcomes. Declaration of Interest. (a) fully declare any financial or other potential conflict of interest


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_7 | Pages 8 - 8
1 May 2021
Jabbal A Stirling PHC Sharma S
Full Access

The purpose of this study is the evaluate the net promotor score of arthroscopic subacromial decompression and rotator cuff repair. The Friends and Family Test, a variant of the Net Promoter Score, was adapted for the National Health Service to evaluate overall patient satisfaction and how likely patients are to recommend an intervention. It ranges from −100 to 100. Positive scores indicate good performance. This study quantifies the scores in 71 patients at 1 year following arthroscopic sub acromial decompression and rotator cuff repair. All of the procedures were performed by 1 consultant shoulder specialist. The patient filled out a shoulder questionnaire pre-operatively, at 6 months and 1 year. The score was 72 for subacromial decompression (n = 32) and 85 for rotator cuff repair +/− decompression (n = 39). Oxford shoulder score was also taken and had a rise of 4.3 and 6.9 respectively. Our study indicates that these procedures are highly valued and are recommended by patients according to the Friends and Family Test. The results of the Friends and Family Test correlated well with postoperative functional improvement and satisfaction. We conclude from this study that a compound score based on the Friends and Family Test is a useful addition to traditional measures of patient satisfaction


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 355 - 355
1 Jul 2008
Benson R McDonnell S Rees J Athanasou N Carr A
Full Access

The aim of this study was to observe the macroscopic and microscopic appearance of the Coracoacromial ligament and Subacromial bursa during Subacromial decompression and correlate it with the outcome at 3 months. Twenty patients with Subacromial Impingement without Rotator Cuff tear and five patients with large/massive irreparable Rotator Cuff tears who underwent a Subacromial Decompression. Patients with other shoulder pathology were excluded. Patients completed an Oxford Shoulder Score pre-operatively and their injection history was noted. At operation the shape of the acromion was noted. The macroscopic appearance of the CA ligament and the Subacromial bursa was classified as normal, mild/moderate and severe. Biopsies of the Subacromial bursa and CA ligament were taken and were analysed using histological and contempory immunocytochemical techniques. A histological analysis was performed using Mayer’s Haemotoxylin and Eosin, Toluidine Blue and Congo Red. Sections were stained with primary antibodies against PCNA (Proliferating cell nuclear antigen), Mast Cell Tryptase, CD3 (T-cell), CD20 (B cell), CD 34 (QBEnd 10), CD45 (Leucocyte Common Antigen), CD68 and D2–40 (Lymphatic Endothelial Marker). Post operatively the patients completed an Oxford Shoulder Score at 3 months. All the patients demonstrated an improvement in their Oxford Shoulder Score. The histological analysis demonstrated thickening of the synovial membrane and increased vascularity within the bursa and ligament. Increased numbers of inflammatory cells were present within the ligament and bursa of patients with impingement compared with massive rotator cuff tears. There was a relationship between outcome and the appearance of the bursa and ligament


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 40 - 40
1 Mar 2009
Shahid R Reddy R Maqsood M
Full Access

Aim: To assess the clinical and functional outcome of proximal humeral fractures (2,3 and 4 parts) fixation with PHILOS (Proximal Humeral interlocked Osteosynthesis) plate using Oxford and DASH scoring system. Methods: Forty-eight consecutive patients were treated with PHILOS plate from the complex proximal humeral fractures. One senior surgeon, using PHILOS plates, operated all patients. The patients were regularly assessed clinically, and plain radiographic evaluation was performed for fracture healing, avascular necrosis, and implant failure. Clinical outcome was measured using Oxford shoulder scores and DASH (Disability of the arm, shoulder, and hand) scores. Patients, who died, lost the follow up or the follow up was less than 3 months were excluded from the study. Results: There were nine male patients (Age: 29–89 yrs) and twenty-nine female patients (Age: 35–93 yrs). Average age: 65 yrs. 74% were two part and three part fractures. Five patients died and four were lost in follow-up. These patients were excluded from the study. Mean follow-up time: 21.7 months (range: 6–44 months). Mean oxford shoulder scores: 41.8 (range: 14–60), Mean DASH scores: 30.2 (range: 0–83.3). There were no cases of non-union. Two plates were removed after fracture healing for complications of impingement and screw cutout. Discussion & conclusion: Proximal humeral fractures constitute 5–7% of all fractures and 26% of humeral fractures.13–16% of proximal humeral fractures are 3 & 4 parts. Proximal humeral fractures have been a challenge to acquire stable fixation. Difficulties have been multifactorial, including osteoporotic bone, angular instability and non-availability of the low-profile implant to avoid impingements. PHILOS plate having locking screws provides angular stability and better hold in osteoporotic bone. It is low profile, which avoids subacromial impingement. Multiple holes in the proximal part of plate for suture anchors helps for soft tissue augmentation. PHILOS plate can provide an excellent stable construct even in multifragmented Osteoporotic proximal humeral fractures. Our study has shown that PHILOS plates are reliable implants for internal fixation of proximal humerus fractures. An inverse correlation was seen between oxford shoulder scores and DASH scores. Patients with higher oxford scores indicating a good outcome had lesser disability scores. Comminuted fractures (four part fractures) had less than satisfactory shoulder scores and higher disability scores. In general, younger patients did better than older patients. This study demonstrates that PHILOS plates provide stable internal fixation for proximal humerus fractures. Age and fracture configuration play a significant role in the clinical outcome of these fractures after internal fixation


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_18 | Pages 31 - 31
1 Dec 2014
Karuppaiah K Khan M Sinha J Arya A
Full Access

Contoured locking plates are commonly used to fix the proximal humerus fractures. Their long-term results are unknown. We present long-term radiological and functional outcome of three and four part fractures of the proximal humerus treated with PHILOS plate. We prospectively analysed 53 consecutive three and four part proximal humerus fractures treated with PHILOS plate between 2002 and 2007. Patients were assessed using Oxford Shoulder Score and DASH score. 44 fractures (21 three part and 23 four part) were available at the final follow up. At a mean follow-up of 8.5 years (6.4 years–10.8 years) the average Oxford Shoulder Score was 43.9 (range 23–48) and the average DASH score was 7.7 (range 0–36.7). 30% of patients required re-operation (five for hemiarthroplasty, three for impingement syndrome, five for removal of implant). Avascular necrosis (AVN) developed in 10 patients, of which only three required hemiarthroplasty. All except one patient were satisfied with the result of their operation. Our study supports the use of locking plates for the treatment of three and four part proximal humeral fractures. In spite of some patients requiring secondary surgical intervention in the first few years, the function of the shoulder continues to improve and in the long term patients were satisfied with the outcome. An important finding of our study is that the post-traumatic AVN of humeral head does not necessarily need major surgical intervention. We believe that the possibility of avascular necrosis should not be a major determinant in the choice of surgical treatment of proximal humeral fractures


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_18 | Pages 10 - 10
1 Apr 2013
Humphry S Raghavan R Dwyer A Chambler A
Full Access

Shoulder resurfacing arthroplasty is a bone conserving option for patients with glenohumeral arthritis. We report the early results of this procedure at our unit with a minimum follow up of 2 years (mean follow up of 36 months). A historical analysis of prospectively collected clinical data was reviewed on a consecutive series of 22 patients (mean age of 73 years) with end stage gleno-humeral arthrosis who had undergone humeral resurfacing hemiarthroplasty performed by a single surgeon. Pain and function were assessed using the Oxford shoulder score and patient satisfaction was recorded. Radiographs were evaluated for implant loosening. 82% of patients had significant improvement in their oxford shoulder score from pre-operatively to two years post-operatively. Complications included one case of intra-operative conversion to a stemmed hemiarthroplasty due to fracture of the humeral head, one case of adhesive capsulitis that required MUA and arthroscopic capsular release and two cases of revision to a total shoulder replacement for pain. Humeral resurfacing arthroplasty is a viable treatment option for glenohumeral arthritis with good short term results


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_29 | Pages 74 - 74
1 Aug 2013
Fleming M Dachs R du Plessis J Vrettos B Roche S
Full Access

Purpose:. To review the union rates, outcomes and complications of angular stable plating of lateral third clavicle fractures. Method:. Between 2007 and 2010 angular stable plates were used in the fixation for seventeen patients with displaced lateral third clavicle fractures (Allman Group II, Type 2). These were identified from surgical log books and operation codes. The surgical and clinical notes as well as X-rays were reviewed. The patients were contacted telephonically. An Oxford Shoulder Score and questions relating to plate removal, scar pain and return to activities were asked. Three patients were not contactable. Results:. There were 16 males. The average age was 44. The average time to union was 3 months (range 2 to 4). There were no complications. The average Oxford Shoulder Score was 13 (range 12–19). No plates have required removal but 2 patients have requested removal for discomfort. All but 3 patients have returned to full activity. Conclusion:. The use of angular stable plates for fixation of type 2 lateral end of clavicle fractures results in excellent union rates by 3 months with only 3 patients requesting elective plate removal. This is in contrast to hook plates which require mandatory removal. No other complication was encountered


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_9 | Pages 25 - 25
1 Feb 2013
Guyver P Jaques A Goubran A Smith C Bunker T
Full Access

Massive tears of the supraspinatus of the rotator cuff lead to painful loss of movement. The literature supports repair of these tears for young healthy individuals, however they present a surgical challenge with historically poor results from both athroscopic and standard open techniques. Prof Bunker has developed a surgical technique for massive rotator cuff tears with a Grammont Osteotomy of the spine of the acromion, when standard surgical techniques will not allow the necessary exposure: the so called “Full Monty”. Patients were entered in to a prospective study to obtain the functional benefit of this procedure. Each patient had a pre-operative American Shoulder Elbow Score (ASES) Oxford Shoulder score (OSS), pain score, range of movement. Post-operatively these measures were repeated along with a patient questionnaire on function and satisfaction. The mean American Shoulder score (ASS) preoperatively was 7 (out of a possible 30) and improved postoperatively to 23(P = 0.00011). The improvement in the Oxford Shoulder Score was 22 (out of a possible 48) preoperatively to 43 postoperatively (0.0001) and 80% patients stated their treatment was “successful”. We believe this a successful surgical option for a patient with “massive” rotator cuff tear that is not amenable to standard surgical techniques


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_13 | Pages 5 - 5
1 Sep 2014
Ryan P Anley C Vrettos B Lambrechts A Roche S
Full Access

Introduction. Resurfacing of the glenohumeral joint has gained popularity since its first introduction in 1958. Advantages of resurfacing over conventional shoulder arthroplasty include preservation of humeral bone stock, closer replication of individual anatomy, reduction of periprosthetic fracture risk, non-violation of medullary canal, and ease of revision to a stemmed component if needed. Materials and Methods. We reviewed a group of patients with arthrosis of the glenohumeral joint who underwent humeral resurfacing, and who were at a minimum of two years post surgery. From January 2000 to March 2011, 51 humeral resurfacing procedures were performed in 49 patients. Patients were contacted for review, and assessed using patient reported outcome measures. An Oxford Shoulder score as well as a subjective satisfaction and outcome questionnaire was completed, as well as details regarding further surgery or revision. 2 patients had died, 11 patients were not contactable, and in 4 the medical files had been lost. In the remaining 32 shoulders, the average follow-up was 5.9 years. The mean age at time of surgery was 62.3 years (range 36 to 84). Results. Complications included 7 revisions (average 2.4 years post surgery), a further 2 patients await revision. There were 2 subscapularis tendon ruptures managed operatively. A further 2 patients required surgery – one for impingement and acromioclavicular joint arthrosis, and the other for instability. The mean Oxford Shoulder score in the unrevised shoulders was 35.4 (range 10 to 47). Conclusion. We have encountered a high rate of revision in patients undergoing humeral resurfacing for glenohumeral arthrosis. In those who have not been revised, there is a wide spread of patient satisfaction as evidenced by the subjective outcome scores. NO DISCLOSURES


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_18 | Pages 30 - 30
1 Dec 2014
Garg S Elzein I Lawrence T Charles E Kumar V Manning P Neumann L Wallace W
Full Access

Background. Nonsurgical treatment of Acromioclavicular joint dislocations is well established. Most patients treated conservatively do well, however, some of them develop persistent symptoms. We have used two different surgical reconstruction techniques for Chronic ACJ dislocation stabilization. The study evaluates the effectiveness of a braided polyester prosthetic ligament and modified Weaver-Dunn reconstruction methods. Methods. 55 patients (mean age 42) with Chronic Acromioclavicular joint dislocation were included in this study. They were treated either by a modified Weaver-Dunn method or a braided polyester prosthetic ligament. Patients were assessed using Oxford shoulder score preoperatively and a minimum of 12 months postoperatively. Results. 31 patients (mean age 40, M=24, F=7) were treated by Modified WD method and 24 patients (mean age 44, M=18, F=6) by Surgilig at a mean21 and 24 months post injury. The mode of injury, presentation of symptoms, grade of injury and mean time at surgery post injury was similar in both the groups. There was a significant improvement (p<0.05) in mean pre and postoperative Oxford Shoulder score in both the groups (WD Mean preop OSS=28, postop OSS= 42, Surgilig Mean preop OSS=26, postop OSS=45). The Surgilig group returned to work significantly earlier (Surgilig; mean 6 wks, WD mean 14 wks). There were 3 failures in the WD group and 1 in Surgilig. Superficial infection was seen in 3 patients requiring antibiotics only. Most of the patients from both groups were satisfied with their result except for 3 patients, one which developed complex regional pain syndrome and two developed secondary shoulder problems resulting in ongoing pain. Conclusions. Chronic ACJ dislocations can be successfully treated surgically by either Weaver-Dunn or Surgilig based on similar satisfaction scores amongst patients of both groups. In this study Surgilig had higher overall success rate, less incidence of failure and allowed earlier return to work


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_II | Pages 51 - 51
1 Feb 2012
Shah Y Syed T Wallace D
Full Access

Mid-shaft humeral fractures in adults are common these days and often present with a management dilemma between operative and non-operative treatment. This study evaluates the outcome of such fractures treated non-operatively over a span of 10 years. In this retrospective study, a review of case notes and radiographs of patients whose mid-shaft humerus fractures were treated non-operatively between 1994 and 2004 was done. Those younger than 16 years and/or who had surgery primarily were excluded. Various factors including patient demographics, mechanism of injury, AO fracture classification and time to union were studied. Mean patient follow-up was 4 years and 6 months. The Oxford shoulder score was used for functional assessment. There was a total of 43 patients, mostly men with involvement of the dominant arm. 5 patients required open reduction and internal fixation with bone grafting for non-union. The average Oxford shoulder score was 18. The majority of patients could resume their jobs and the average time to union was 9 weeks. We conclude from this study that there is a high union rate in the mid-shaft humeral fractures in adults treated non-operatively, with an acceptable functional outcome


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_4 | Pages 3 - 3
1 Mar 2020
Mackenzie S Hackney R Crosbie G Ruthven A Keating J
Full Access

Glenohumeral dislocation is complicated with a greater tuberosity fracture in 16% of cases. Debate regarding the safety of closed reduction in the emergency department exists, with concerns over fracture propagation during the reduction manoeuvre. The study aim was to report the results of closed reduction, identify complications and define outcome for these injuries. 188 consecutive glenohumeral dislocations with a tuberosity fracture were identified from a prospective database from 2014–2017. 182 had an attempted closed reduction under appropriate sedation using standard techniques, five were manipulated in theatre due to contra-indications to sedation. Clinical, radiographic and patient reported outcomes, in the form of the QuickDASH and Oxford Shoulder Score (OSS), were collected. A closed reduction in the emergency department was successful in 162 (86%) patients. Two iatrogenic fractures of the proximal humerus occurred, one in the emergency department and one in theatre, representing a 1% risk. 35 (19%) of patients presented with a nerve lesion due to dislocation. Surgery was performed in 19 (10%) cases for persistent or early displacement (< 2 weeks) of the greater tuberosity fragment. Surgery resulted in QuickDASH and OSS scores comparable to those patients in whom the tuberosity healed spontaneously in an anatomical position (p=0.13). 18 patients developed adhesive capsulitis (10%). Glenohumeral dislocation with greater tuberosity fracture can be safely treated by closed reduction within the emergency department with a low risk of humeral neck fracture. Persistent or early displacement of the tuberosity fragment will occur in 10% of cases and is an indication for surgery


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXII | Pages 13 - 13
1 Jul 2012
Fetherston CR Simon DW
Full Access

Adhesive capsulitis of the shoulder is a common debilitating condition with prevalence in the order of 2 to 5%. Whilst it is usually a self-limiting condition, patients are typically not willing, nor are they able, to wait to the end of the recovery phase. A number of treatment strategies have been described. Manipulation under anaesthesia can significantly increase motion in all planes, but carries a significant risk of fracture. Capsular release also significantly improves motion with fewer potential side effects. We hypothesise that performing an arthroscopic excision of the abnormal capsulitis tissue will give better results with least risk of recurrence. Data was collected both retrospectively and prospectively for patients undergoing this procedure. Range of motion and Oxford shoulder scores was documented pre-operatively and post-operatively, at 6 weeks, 3 months and 6 months. 41 patients were included. At 3 months mean flexion had increased from 101 to 152 degrees, abduction from 91 to 151 degrees, and external rotation from 18 to 44 degrees. Mean Oxford shoulder score had increased from 20.6 to 35.8 at 3 months. The results support the use of this technique for treating adhesive capsulitis. Larger patient numbers and longer term follow up will help compare it against the other well established techniques


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 10 | Pages 1409 - 1413
1 Oct 2012
Roberts VI Komarasamy B Pandey R

Controversy surrounds the management of displaced three- and four-part fractures of the proximal humerus. The percutaneous Resch technique of stabilisation involves minimal soft-tissue dissection and a reduced risk of stiffness and avascular necrosis. However, it requires a second operation to remove Kirschner wires and the humeral block. We describe a modification of this technique that dispenses with the need for this second operation and relies on a sequential pattern of screw placement. We report the outcome of 32 three- or four-part fractures of the proximal humerus treated in this way at a mean follow-up of 3.8 years (2 to 8)). There were 14 men and 18 women with a mean age of 56 years (28 to 83). At final follow-up the mean Oxford shoulder scores were 38 (31 to 44) and 39 (31 to 42), and the mean Constant scores were 79 (65 to 92) and 72 (70 to 80) for three- and four-part fractures, respectively. We further analysed the results in patients aged < 60 years with high-energy fractures and those aged ≥ 60 years with osteoporotic fractures. There were no cases of nonunion or avascular necrosis. The results were good and comparable to those previously reported for the Resch technique and other means of fixation for proximal humeral fractures. We would recommend this modification of the technique for the treatment of displaced three-part and four-part fractures in patients both younger and older than 60 years of age