EARLY OUTCOME OF AEQUALIS HUMERAL HEAD RESURFACING IN PATIENTS WITH GLENO-HUMERAL ARTHRITIS

The South West Orthopaedic Club (SWOC)



Abstract

Shoulder resurfacing arthroplasty is a bone conserving option for patients with glenohumeral arthritis. We report the early results of this procedure at our unit with a minimum follow up of 2 years (mean follow up of 36 months).

A historical analysis of prospectively collected clinical data was reviewed on a consecutive series of 22 patients (mean age of 73 years) with end stage gleno-humeral arthrosis who had undergone humeral resurfacing hemiarthroplasty performed by a single surgeon. Pain and function were assessed using the Oxford shoulder score and patient satisfaction was recorded. Radiographs were evaluated for implant loosening.

82% of patients had significant improvement in their oxford shoulder score from pre-operatively to two years post-operatively. Complications included one case of intra-operative conversion to a stemmed hemiarthroplasty due to fracture of the humeral head, one case of adhesive capsulitis that required MUA and arthroscopic capsular release and two cases of revision to a total shoulder replacement for pain. Humeral resurfacing arthroplasty is a viable treatment option for glenohumeral arthritis with good short term results.