header advert
Results 1 - 3 of 3
Results per page:
Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_5 | Pages 72 - 72
1 Mar 2017
Park S Kang H Yang T
Full Access

Introduction

Embolism in total arthroplasty or hip fractures, coagulation disorders, such as a variety of ways for the prevention of complications of anticoagulation therapy with medication is being done well. The purpose of this study, a representative of the anticoagulation therapy with enoxaparin and drug rivaroxaban of coagulation tests performed in patients between the two groups was to determine whether statistically significant differences.

Methods

47 patients who underwent arthroscopic surgery were randomly divided into two groups to rivaroxaban and enoxaparin group, and we performed coagulation tests before and 5 days after arthroscopic surgery to two drugs groups in order to investigate about the difference in clotting capacity.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_5 | Pages 73 - 73
1 Mar 2017
Park S Kang H Yang T
Full Access

Introduction

The purpose of this study was to demonstrate postoperative improvement and high satisfaction rates after a surgical approach that includes arthroscopic labral repair only, in patients with borderline dysplasia, without instability.

Methods

Between September 2009 and December 2011, patients less than 50 years old who underwent hip arthroscopy for symptomatic intra-articular hip disorders, with a lateral center-edge (CE) angle between 20 and 25, were included in this study. Patients with Tönnis grade 2 or greater, hip joint space narrowing, severe hip dysplasia (CE〈20), hip joint instability and Legg-Calve-Perthes disease were excluded. Patient-reported outcome scores, including the modified Harris Hip Score (mHHS), Western Ontario and McMaster Universities Arthritis index (WOMAC), and visual analog scale (VAS) for pain were obtained in all patients preoperatively and at 1, 2, and 3 years postoperatively.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 50 - 50
1 Jan 2016
Hsiao C Tsai Y Yang T Hsu C Tu Y
Full Access

Introduction

Distal femur fracture is a critical issue in orthopedic trauma, because it is difficult to manage especially in cases with intra-articular fracture. Osteoporosis may cause instability of implant and increase complications. Few studies investigate on the stability of distal femur osteoporotic fracture and the behaviors under cycling. Our hypothesis was that the stiffness of construct would decrease as cycling in osteoporotic bone.

Materials and Methods

Seven cadaver specimens were used in this study. Relative bone density for each specimen was evaluated using CT scanning by three known calibration phantoms scanned simultaneously with the specimen. All cadaver specimens were divided normal (group 1) and osteoporosis (group 2) in accordance with the bone density. The titanium distal femur locking plates with 6 screws placed in distal femur condyle and 4 in shaft. A 10 mm gap with 65 mm proximal to the center of articular surface and a vertical fractural line between intra-articular were created to simulate AO C2 type fracture. Each specimen was cyclically loaded in two-phase at a frequency of 2 Hz. Phase 1 was set at 1000 N for 10000 cycles. In phase 2, the load was set at 2000 N for 10000 cycles. Then, the specimen was loaded up to failure at a rate of 5 mm/min. Stiffness was evaluated from the linear portion of load-displacement curve at 2000 cycle interval.