header advert
Results 1 - 7 of 7
Results per page:
Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_9 | Pages 77 - 77
1 May 2016
Nakata K Kitada M Tamura S Owaki H Fuji T
Full Access

Introduction

Short stems have been developed for some years for preservation of femoral bone stock and achieve physiological proximal loading. Shortening stem length is a merit for bone stock preservation. However, it might lead to reduction of primary stability. We investigated relationship between stem length and primary stability by patient specific finite element analysis (FEA).

Materials and Methods

Thirty-one hips in 31 patients were performed total hip arthroplasty with standard length tapered wedge-shaped (TW) cementless stem (CTi-II: Corin, Cirencester, UK). There were 6 males and 25 females. The average age at operation was 69 years old. The average body mass index was 23.9 kg/m2. Primary diagnoses were secondary osteoarthritis due to developmental dysplasia of the hip in 29 hips. Femoral canal shapes were normal in 21, stovepipe in 6 and champagne-flute in 4 hips. Bone qualities were type A in 6, B in 19 and C in 6 hips.

The patients underwent computed tomography (CT) preoperatively and postoperatively. We constructed preoperative three dimensional (3D) femur surface models from preoperative CT data with individual bone mineral density (BMD) mapping. The postoperative 3D femur and rough stem surface models were obtained from postoperative CT data. The coordinates of the postoperative femur were transformed to fit the preoperative femur model. A precise stem model constructed using computer-assisted design data was matched to the transformed rough stem model using the iterative closest point algorithm. We obtained a patient-specific model with the proximal bone geometry, allocation of BMD and stem alignment. We estimated the average of axial and rotational micromotion (MM) at stem-bone interface and the ratio of area (MM � 40 micrometers) on the porous surface in order to analyze primary stability of TW stem with several lengths (standard (100 %), 75 %, 50 %, 40 % and 30 % length).


The Bone & Joint Journal
Vol. 98-B, Issue 3 | Pages 349 - 358
1 Mar 2016
Akiyama K Nakata K Kitada M Yamamura M Ohori T Owaki H Fuji T

Aims

We investigated changes in the axial alignment of the ipsilateral hip and knee after total hip arthroplasty (THA).

Patients and Methods

We reviewed 152 patients undergoing primary THA (163 hips; 22 hips in men, 141 hips in women) without a pre-operative flexion contracture. The mean age was 64 years (30 to 88). The diagnosis was osteoarthritis (OA) in 151 hips (primary in 18 hips, and secondary to dysplasia in 133) and non-OA in 12 hips. A posterolateral approach with repair of the external rotators was used in 134 hips and an anterior approach in 29 hips. We measured changes in leg length and offset on radiographs, and femoral anteversion, internal rotation of the hip and lateral patellar tilt on CT scans, pre- and post-operatively.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 448 - 448
1 Dec 2013
Nakata K Kitada M Akiyama K Owaki H Fuji T
Full Access

[Introduction]

Short tapered wedge-shaped cementless (TW) stems have been widely used for several years. The concept of fixation of TW stem is wedge-fit fixation in the proximal metaphysis. Developmental dysplasia of the hip (DDH) has anatomical abnormality, such as excessive femoral anteversion, short femoral neck length, narrow femoral cavity, or proximal-distal mismatching of the femoral canal. Therefore, Mismatching between stem and bone might be occurred in DDH. We evaluated intramedullary matching of short TW stem for DDH by three dimensional (3D) digital template in order to clarify whether mismatching between stem and bone is seen in DDH implanted short TW stem.

[Materials and Methods]

One hundred hips (92 patients) with DDH were performed preoperative simulation for total hip arthroplasty by 3D digital template system (ZedHip: Lexi, Tokyo, Japan). The average age was 63.5 years old. There were 12 males and 80 females. The average bone mass index was 21.5 kg/m2. Femoral canal shape was normal in 71, champagne-flute in 16 and stovepipe in 13 hips. Bone quality was classified into type A in 23, type B in 74 and type C in 3 hips. Preoperative computed tomography data were used for 3D digital template and reconstructed to 3D femoral model. Short TW stem (Taperloc Complete Microplasty: Biomet, Warsaw, IN) model constructed from computer-assisted design was matched to the reconstructed femoral model. Short TW stem model was in principle implanted according to the femoral neck anteversion with neutral alignment (varus and valgus < 2 degrees, flexion and extension < 2 degrees) at the coronal and sagittal plane of the femur. Stem size was determined in order to obtain the largest intramedullary matching at the coronal plane. Area of stem fitting with the cortical bone was investigated at 10 mm intervals above and below of mid minor trochanter. Intramedullary matching pattern was classified into proximal mediolateral metaphyseal fit, proximal flare fit and diaphyseal fit at multiple reconstructed planes of the 3D femoral model according to stem fitting area.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_28 | Pages 100 - 100
1 Aug 2013
Nakamura N Iwana D Kitada M Maeda Y Sakai T
Full Access

The occurrence of impingement can lead to instability, accelerated wear, and unexplained pain after THA. While implant and bony impingement were widely investigated, importance of soft tissue impingement was unclear. In the THA through posterior approach, it is known that posterior soft tissue repair can decrease the risk of dislocation. However, it is not known whether anterior soft tissue impingement by anterior hip capsule will influence hip ROM. The purpose of this study is to quantitatively measure the effect of anterior capsule resection on hip ROM in vivo during posterior approach THA using hip navigation system.

From June 2011, 26 hips (25 patients) that underwent primary THA using Stryker CT-based hip navigation system were the subjects. All were female osteoarthritis patients and the average age at the operation was 59 (47–76) years. Intraoperatively, acetabular cup and femoral stem placement were performed through posterior approach under the navigation system. After reduction of the joint, we measured hip ROM using the same navigation system. We measured them before and after the resection of anterior hip capsule and compared the difference.

After the resection of anterior hip capsule, the average increases of ROM were 0.7±3.5 degrees for flexion, 2.3±2.3 degrees for extension, 1.1±2.3 degrees for abduction and 2.1±2.9 degrees for external rotation at flexion 0 degree compared with ROM before the resection. However, it significantly increased 7.5±5.1 degrees for internal rotation at flexion 90 degree (range; −3–20, paired t-test p<0.001) and 6.1±5.5 degrees for internal rotation at flexion 45 degree (range; −4–18, p<0.001).

In this study, we used navigation system for assessment of soft tissue impingement. We found that during posterior approach THA, resection of anterior hip capsule brought about significant increase of ROM, especially in the direction of flexion with internal rotation. We also found that this procedure did not change ROM of flexion, extension, abduction and external rotation. These results indicated that, during THA through posterior approach, resection of anterior hip capsule could reduce the risk of posterior instability without increasing the risk of anterior instability.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLIV | Pages 34 - 34
1 Oct 2012
Nakamura N Murase T Tsuda K Sugano N Iwana D Kitada M Kawakami H
Full Access

We developed a custom-made template for corrective femoral osteotomy during THA in a patient with a previous Schanz osteotomy.

A seventy-year-old woman presented to our clinic with a chief complaint of right hip, left knee and left ankle pain with marked limp. She had undergone Schanz osteotomy of the left femur because of high dislocation of the left hip when she was 20 years old. After right THA was performed, we decided to perform left THA with corrective femoral osteotomy. A custom-made osteotomy template was designed and manufactured with use of CT data. During surgery, we placed the template on the bone surface, cut the bone through a slit on the template, and corrected the deformity as preoperatively simulated. Two years after surgery, she had no pain in any joints, could walk more than one hour without limp. Japanese Orthopedic Association hip score were 100 points for both hips.

THA in patients with previous Schanz osteotomy was reported to be technically demanding and the rate of complications was high. In 2008, Murase T et al. developed a system, including a 3D computer simulation program and a custom-made template to corrective osteotomy of malunited fractures of the upper extremity. We applied the system to corrective femoral osteotomy during THA in a patient with a previous Schanz osteotomy. The surgical procedure was technically easy and accurate osteotomy brought the patient to acquire good alignment of lower extremities with good clinical results.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_VIII | Pages 54 - 54
1 Mar 2012
Sakai T Nakamura N Iwana D Kitada M Nishii T Takao M Yoshikawa H Sugano N
Full Access

Introduction

Femoral neck fracture (FNF) is a common trauma in the elderly individuals. When the blood supply to the femoral head is impaired with a fracture event, the reduction or disruption of blood supply to the bone, hypoxia, leads to death of the bone marrow and trabecular bone, and eventual late segmental collapse. In the reparative process, osteoblasts and osteoclasts perform the important function of repairing the fracture site at the femoral neck. However, the reparative reaction including angiogenesis and osteogenesis remains unknown. In order to investigate the reparative reaction in patients with FNF, the distribution of tartrate resistant acid phosphatase (TRAP)-positive cells and expression of HIF-1 alpha, VEGF, and FGF-2 were observed in 36 hips in 35 patients.

Methods

There were 6 men and 30 women who had a mean age of 79 years (range, 58 to 94 years). There were 10 hips with Garden stage 3, and 26 hips with Garden stage 4. The mean duration from onset to the surgery was 12 days (range: 1 to 82 days). Hematoxylin eosin staining, TRAP staining, immunohistochemistry using anti HIF-1 alpha, anti VEGF, and anti FGF-2 antibodies were performed for retrieved whole femoral heads. As a control, one femoral head in a patient who underwent wide resection for metastatic acetabular tumor was used.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 110 - 110
1 Mar 2010
Tsuda K Miki H Kitada M Nakamura N Nishii T Sakai T Takao M Suzuki N Sugano N
Full Access

The anterior pelvic plane (APP) through the bilateral anterior superior iliac spines (ASIS) and pubic tuberosities is often used as a pelvic reference in measuring orientation of the acetabular cup in total hip arthroplasty. Apophyses such as ASIS are, however, anatomically variable among patients and APP does not always represent the functional pelvic tilt in the sagittal plane in each patient. Therefore, malposition of the cup and recurrent dislocation may occur even though the cup is placed in a safe zone when measured against APP. We analyzed dynamic pelvic tilt angle in the sagittal plane using a motion analysis system after THA and we found a case of recurrent dislocation due to an unusual APP tilt.

A 77-year-old woman underwent primary THA 3 years ago and cup re-implantation was done with the use of a 10-degree elevated liner and the head diameter was increased from 26mm to 28 mm after two anterior dislocations. However, posterior dislocation occurred 11 times after this. A second revision was performed with a 36 mm head and cup anteversion was optimized against APP. Further posterior dislocations occurred twice again. To probe the cause of recurrent dislocation, we performed motion analysis using a 6-camera VICON system and the markers were registered to the bone and implant models based on the postoperative CT images. This system visually represents four-dimensional dynamic motions that include the time sequential transitions of components and their posture. The cup had been placed in 6 degrees of radiographic anteversion against APP, and in −13 degrees of radiographic retroversion in supine (FPP), because the pelvic flexion angle in supine was 17.6 degrees. Furthermore, when standing, the pelvic flexion angle increased 10 degrees.

Malposition of the acetabular cup in THA is the most common cause of dislocation. To avoid errors in cup placement, computer navigation systems have been introduced and most of the navigation systems refer APP to establish cup orientation. There are two drawbacks in using APP as the reference. One is that apophyses such as ASIS develop variably in each patient with a resulting variability in APP tilt in the sagittal plane in supine. The other is significant changes in pelvis tilt during various activities of daily living such as standing, walking, and sitting. Therefore, even if cup orientation is acceptable when referencing APP, it can be mal-oriented in a functional position of the pelvis as in this case, which showed proper anteversion against APP but retroversion in supine, standing and sitting.

In conclusion, we found that there exists a case in which APP is not a suitable pelvic reference in determining orientation of the cup.