Vol. 92-B, Issue SUPP_IV | Pages 616 - 617
1 Oct 2010
Hudetz D Ivkovic A Jelic M Maticic D Pascher A Pecina M Windhager R
Full Access

Introduction: Articular cartilage injuries are very common, and if untreated can become symptomatic and progressively lead to premature osteoarthritis. It is well known that damaged cartilage has very limited potential to heal itself, and repair and regeneration of hyaline cartilage remain a clinical and scientific challenge. There are no pharmacological methods that can regenerate cartilage, and currently clinical treatments of debridement, chondrocyte transplantation and marrow stimulation have not been shown to restore consistently a durable articular surface. Tissue engineering and gene therapy concepts may improve cartilage repair by introducing cells, scaffolds, growth factors and other potential modulators of cartilage healing process. When analyzing cartilage treatment outcomes, traditionally we use macro- and microscopic assessment, immunohistochemistry, biochemical characterization etc. Recently, it has been postulated that biomechanical properties of newly formed cartilage are just as important, and novel methods of measurements have been proposed.

Materials and methods: 38 defects were created on weight-bearing part of the medial femoral condyle in sheep. The sheep were randomly assigned to one of four groups. In the bone marrow clot (BMC) group, the sheep were implanted with untreated autologous bone marrow clot that was aspirated from iliac crest of respected animal. In the bone marrow transduced with Ad. GFP (GFP) group, the sheep were implanted with autologous bone marrow clots genetically modified to over express green fluorescent protein (GFP). In the bone marrow transduced with Ad. TGF-β1 (TGF) group, the sheep were implanted with autologous bone marrow clots genetically modified to over express transforming growth factor-β1. Untreated sheep served as a control (defect without implant), and native cartilage served as positive control. Specimens were collected after 6 months and analyzed by single-impact micro-indentation (SIMI), atomic force microscope (AFM) and scanning electron microscope (SEM).

Results: SIMI and AFM measurements showed that repair tissue has greater Young’s elastic modulus then native cartilage. There was a statistically significant difference between TGF-β1, GFP and BMC groups. SEM analysis showed presence of structurally organized collagen molecules in TGF-β1, GFP and BMC groups.

Conclusion: The results of this study showed that it is possible to enhance cartilage repair process by means of genetically modified bone marrow. Furthermore, biomechanical data obtained with SIMI, AFM and SEM provided more detailed insight into articular cartilage function and structure, and in future may be of practical importance for a better understanding of both cartilage mechanics and cartilage disease progression.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_I | Pages 36 - 36
1 Mar 2006
Bilic R Simic P Jelic M Stern-Padovan R Vukicevic S Pecina M
Full Access

Background: Bone morphogenetic proteins (BMPs) induce new bone in patients with bone defects and at extraskeletal sites in animals. Standard treatment for symptomatic scaphoid non-unions is bone graft with or without internal fixation by a screw or wires. We tested the ability of human recombinant osteogenic protein-1 (OP-1, BMP-7) with compressed autologous or allogeneic bone graft to accelerate the healing of scaphoid non-union.

Study Design: Randomized and controlled pilot study in 17 patients with a scaphoid nonunion.

Methods: Patients were randomly assigned to one of three groups: (1) Autologous iliac graft (n=6), (2) Autologous iliac graft + OP-1 (n=6) and (3) Allogeneic iliac graft + OP-1 (n=5). Radiographic, scintigraphic and clinical outcomes were assessed throughout the follow-up period of 24 months.

Results: OP-1 improved the performance of both autologous and allogeneic bone implants. Three dimensional helical CT scans and scintigraphy showed that the pre-existing sclerotic bone within proximal scaphoid poles was mainly replaced in OP-1 treated patients with well vascularized new bone. Addition of OP-1 to allogeneic bone implant equalized the clinical outcome with the autologous graft procedure and enabled circumventing the second donor graft harvest procedure resulting in less blood loss, shorter anesthesia and no pain at the donor side.

Conclusion: This is the first evidence that a recombinant human BMP accelerates scaphoid bone non-union repair and resorption of sclerotic bone in this specific microenvironment.