header advert
Results 1 - 5 of 5
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 125 - 125
11 Apr 2023
Woodford S Robinson D Lee P Rohrle O Mehl A Ackland D
Full Access

Occlusal loading and muscle forces during mastication aids in assessment of dental restorations and implants and jaw implant design; however, three-dimensional bite forces cannot be measured with conventional transducers, which obstruct the native occlusion. The aim of this study was to combine accurate jaw kinematics measurements, together with subject-specific computational modelling, to estimate subject-specific occlusal loading and muscle forces during mastication.

Motion experiments were performed on one male participant (age: 39yrs, weight: 82kg) with healthy dentition. Two low-profile magnetic sensors were fixed to the participant's teeth and the two dental arches digitised using an intra-oral scanner. The participant performed ten continuous of chewing on a polyurethane rubber sample of known material properties, followed by maximal compression (clenching). This was repeated at the molars, premolars of both the left and right sides, and central incisors. Jaw motion was simultaneously recorded from the sensors, and finite element modelling used to estimate bite force. Specifically, simulations of chewing and biting were performed by driving the model using the measured kinematics, and bite force magnitude and direction quantified. Muscle forces were then evaluated using a rigid-body musculoskeletal model of the patient's jaw.

The first molars generated the largest bite forces during chewing (left: 309 N, right: 311 N) and maximum-force biting (left: 496 N, right: 495 N). The incisors generated the smallest bite forces during chewing (75 N) and maximum-force biting (114 N). The anterior temporalis and superficial masseter muscles had the largest contribution to maximum bite force, followed by the posterior temporalis and medial pterygoid muscles.

This study presents a new method for estimating dynamic occlusal loading and muscle forces during mastication. These techniques provide new knowledge of jaw biomechanics, including muscle and occlusal loading, which will be useful in surgical planning and jaw implant design.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 124 - 124
11 Apr 2023
Woodford S Robinson D Lee P Abduo J Dimitroulis G Ackland D
Full Access

Total temporomandibular joint (TMJ) replacements reduce pain and improve quality of life in patients suffering from end-stage TMJ disorders, such as osteoarthritis and trauma. Jaw kinematics measurements following TMJ arthroplasty provide a basis for evaluating implant performance and jaw function. The aim of this study is to provide the first measurements of three-dimensional kinematics of the jaw in patients following unilateral and bilateral prosthetic TMJ surgeries.

Jaw motion tracking experiments were performed on 7 healthy control participants, 3 unilateral and 1 bilateral TMJ replacement patients. Custom-made mouthpieces were manufactured for each participant's mandibular and maxillary teeth, with each supporting three retroreflective markers anterior to the participant's lip line. Participants performed 15 trials each of maximum jaw opening, lateral and protrusive movements. Marker trajectories were simultaneously measured using an optoelectronic tracking system. Laser scans taken of each dental plate, together with CT scans of each patient, were used to register the plate position to each participant's jaw geometry, allowing 3D condylar motion to be quantified from the marker trajectories.

The maximum mouth opening capacity of joint replacement patients was comparable to healthy controls with average incisal inferior translations of 37.5mm, 38.4mm and 33.6mm for the controls, unilateral and bilateral joint replacement patients respectively. During mouth opening the maximum anterior translation of prosthetic condyles was 2.4mm, compared to 10.6mm for controls. Prosthetic condyles had limited anterior motion compared to natural condyles, in unilateral patients this resulted in asymmetric opening and protrusive movements and the capacity to laterally move their jaw towards their pathological side only. For the bilateral patient, protrusive and lateral jaw movement capacity was minimal.

Total TMJ replacement surgery facilitates normal mouth opening capacity and lateral and inferior condylar movements but limits anterior condylar motion. This study provides future direction for TMJ implant design.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 38 - 38
23 Feb 2023
Ernstbrunner L Almond M Rupasinghe H Jo O Zbeda R Ackland D Ek E
Full Access

The extracortical single-button (SB) inlay repair is one of the most preferred distal biceps tendon repair techniques. However, specific complications such as neurovascular injury and non-anatomic repairs have led to the development of techniques that utilize intracortical double-button (DB) fixation.

To compare the biomechanical stability of the extracortical SB repair with the anatomical DB repair technique.

Controlled laboratory study.

The distal biceps tendon was transected in 18 cadaveric elbows from 9 donors. One elbow of each donor was randomly assigned to the extracortical SBor anatomical DB group. Both groups were cyclically loaded with 60N over 1000 cycles between 90° of flexion and full extension. The elbow was then fixed in 90° of flexion and the repair construct loaded to failure. Gap-formation and construct stiffness during cyclic loading, and ultimate load to failure was analysed.

After 1000 cycles, the anatomical DB technique compared with the extracortical SB technique showed significantly less gap-formation (mean difference 1.2 mm; p=0.017) and significantly more construct stiffness (mean difference 31 N/mm; p=0.023). Ultimate load to failure was not significantly different comparing both groups (SB, 277 N ±92 vs. DB, 285 N ±135; p=0.859). The failure mode in the anatomical DB group was significantly different compared with the extracortical SB technique (p=0.002) and was due to fracture avulsion of the BicepsButton in 7 out of 9 specimens (vs. none in SB group).

Our study shows that the intracortical DB technique produces equivalent or superior biomechanical performance to the SB technique. The DB repair technique reduces the risk of nerve injury and better restores the anatomical footprint of biceps tendon. The DB technique may offer a clinically viable alternative to the SB repair technique.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 39 - 39
23 Feb 2023
Jo O Almond M Rupasinghe H Jo O Ackland D Ernstbrunner L Ek E
Full Access

Neer Type-IIB lateral clavicle fractures are inherently unstable fractures with associated disruption of the coracoclavicular (CC) ligaments. A novel plating technique using a superior lateral locking plate with antero-posterior (AP) locking screws, resulting in orthogonal fixation in the lateral fragment has been designed to enhance stability. The purpose of this study was to biomechanically compare three different clavicle plating constructs.

24 fresh-frozen cadaveric shoulders were randomised into three groups (n=8 specimens). Group 1: lateral locking plate only (Medartis Aptus Superior Lateral Plate); Group 2: lateral locking plate with CC stabilisation (Nr. 2 FiberWire); and Group 3: lateral locking plate with two AP locking screws stabilising the lateral fragment. Data was analysed for gap formation after cyclic loading, construct stiffness and ultimate load to failure, defined by a marked decrease in the load displacement curve.

After 500 cycles, there was no statistically significant difference between the three groups in gap-formation (p = 0.179). Ultimate load to failure was significantly higher in Group 3 compared to Group 1 (286N vs. 167N; p = 0.022), but not to Group 2 (286N vs. 246N; p = 0.604). There were no statistically significant differences in stiffness (Group 1: 504N/mm; Group 2: 564N/mm; Group 3: 512N/mm; p = 0.712). Peri-implant fracture was the primary mode of failure for all three groups, with Group 3 demonstrating the lowest rate of peri-implant fractures (Group 1: 6/8; Group 2: 7/8, Group 3: 4/8; p = 0.243).

The lateral locking plate with orthogonal AP locking screw fixation in the lateral fragment demonstrated the greatest ultimate failure load, followed by the lateral locking plate with CC stabilization. The use of orthogonal screw fixation in the distal fragment may negate against the need for CC stabilization in these types of fractures, thus minimizing surgical dissection around the coracoid and potential complications.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 183 - 183
1 Mar 2010
Ackland D Yap V Hardige A Ackland M Williams J de Steiger R
Full Access

There are several different ways of preparing the femoral canal prior to cementing a hip prosthesis. This study investigated the mechanical strength of the cement-bone interface of four different types of preparation determined by the maximum tensile force required to separate a cemented prosthesis from its cancellous bone origin.

Forty-eight fresh-frozen ox femora were prepared for hip arthroplasty, In a four-way comparison, groups of eleven femora were prepared by irrigation using

syringe injected normal saline;

hydrogen-peroxide soaked gauze;

pulse-lavage brushing; and

pulse-lavage brushing and hydrogen-peroxide soaked gauze combination.

Specimens were secured to a Material-test System (MTS), and the femoral implant pulled from the femur uni-axially at a rate of 5mm/min. The ‘pull-out strength’ was defined as the maximum tension recorded by the MTS during separation. Cement interdigitation was also inspected for each technique by microscopy of eight bone-implant transverse sections taken from prepared specimens.

Following an analysis of variance and pair-wise Fisher comparison, the average pull-out strength of the cemented prosthesis was significantly higher (P< 0.001) using pulse-lavage brushing (mean 8049.2 N), and pulse-lavage brushing in combination with hydrogen-peroxide soaked gauze (mean 8489.1 N), than with normal saline irrigation (mean 947.1 N) or hydrogen-peroxide soaked gauze preparation (mean 1832.6 N). Prosthesis pull-out strength following pulse-lavage brushing in combination with hydrogen-peroxide soaked gauze was not significantly different (P> 0.05) than preparing with pulse-lavage brushing alone. Low and high power microscopy of specimen transverse sections revealed the greatest levels of cement penetration in specimens prepared using pulse-lavage brushing.

This study demonstrated that one of the most effective preparations of the femoral canal for optimal mechanical fixation between cement and cancellous bone is pulse- lavage brushing. The use of hydrogen-peroxide soaked gauze in femoral canal preparation, either alone or in combination with pulse-lavage brushing, may not significantly improve prosthesis fixation.