header advert
Results 1 - 3 of 3
Results per page:
Bone & Joint Open
Vol. 5, Issue 3 | Pages 154 - 161
1 Mar 2024
Homma Y Zhuang X Watari T Hayashi K Baba T Kamath A Ishijima M

Aims

It is important to analyze objectively the hammering sound in cup press-fit technique in total hip arthroplasty (THA) in order to better understand the change of the sound during impaction. We hypothesized that a specific characteristic would present in a hammering sound with successful fixation. We designed the study to quantitatively investigate the acoustic characteristics during cementless cup impaction in THA.

Methods

In 52 THAs performed between November 2018 and April 2022, the acoustic parameters of the hammering sound of 224 impacts of successful press-fit fixation, and 55 impacts of unsuccessful press-fit fixation, were analyzed. The successful fixation was defined if the following two criteria were met: 1) intraoperatively, the stability of the cup was retained after manual application of the torque test; and 2) at one month postoperatively, the cup showed no translation on radiograph. Each hammering sound was converted to sound pressures in 24 frequency bands by fast Fourier transform analysis. Basic patient characteristics were assessed as potential contributors to the hammering sound.


Bone & Joint Open
Vol. 4, Issue 3 | Pages 154 - 161
28 Mar 2023
Homma Y Zhuang X Watari T Hayashi K Baba T Kamath A Ishijima M

Aims

It is important to analyze objectively the hammering sound in cup press-fit technique in total hip arthroplasty (THA) in order to better understand the change of the sound during impaction. We hypothesized that a specific characteristic would present in a hammering sound with successful fixation. We designed the study to quantitatively investigate the acoustic characteristics during cementless cup impaction in THA.

Methods

In 52 THAs performed between November 2018 and April 2022, the acoustic parameters of the hammering sound of 224 impacts of successful press-fit fixation, and 55 impacts of unsuccessful press-fit fixation, were analyzed. The successful fixation was defined if the following two criteria were met: 1) intraoperatively, the stability of the cup was retained after manual application of the torque test; and 2) at one month postoperatively, the cup showed no translation on radiograph. Each hammering sound was converted to sound pressures in 24 frequency bands by fast Fourier transform analysis. Basic patient characteristics were assessed as potential contributors to the hammering sound.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_10 | Pages 7 - 7
1 Oct 2020
Webb ML Scanlon CM Kerbel Y Evangelista P Kamath A Nelson CL
Full Access

Introduction

The long-term survival of modern ceramic-ceramic bearings in young active patients with osteonecrosis undergoing total hip arthroplasty (THA) is unknown. A previously published study of this series at 5-year follow-up demonstrated an extremely high activity level. The purpose of this study is to examine whether this very high activity level is associated with ceramic-on-ceramic THA failure at long-term follow-up.

Methods

This is a retrospective review of a single-surgeon at an academic medical center between years 2003–2010. Inclusion criteria were consecutive series of ceramic-on-ceramic articulations in patients younger than 50 with a diagnosis of osteonecrosis. Median follow-up was 12.4 years (range 10–17). Data was collected via mail, telephone, and e-mail surveys. Exclusion criteria included deceased prior to follow-up. Preoperative and postoperative Western Ontario and McMaster University Arthritis Index (WOMAC) and University of California at Los Angeles Activity scores (UCLA) were collected. Student t-tests were used as appropriate.