header advert
Results 1 - 100 of 896
Results per page:
Bone & Joint Open
Vol. 4, Issue 6 | Pages 408 - 415
1 Jun 2023
Ramkumar PN Shaikh HJF Woo JJ Haeberle HS Pang M Brooks PJ

Aims. The aims of the study were to report for a cohort aged younger than 40 years: 1) indications for HRA; 2) patient-reported outcomes in terms of the modified Harris Hip Score (HHS); 3) dislocation rate; and 4) revision rate. Methods. This retrospective analysis identified 267 hips from 224 patients who underwent an hip resurfacing arthroplasty (HRA) from a single fellowship-trained surgeon using the direct lateral approach between 2007 and 2019. Inclusion criteria was minimum two-year follow-up, and age younger than 40 years. Patients were followed using a prospectively maintained institutional database. Results. A total of 217 hips (81%) were included for follow-up analysis at a mean of 3.8 years. Of the 23 females who underwent HRA, none were revised, and the median head size was 46 mm (compared to 50 mm for males). The most common indication for HRA was femoroacetabular impingement syndrome (n = 133), and avascular necrosis ( (n = 53). Mean postoperative HHS was 100 at two and five years. No dislocations occurred. A total of four hips (1.8%) required reoperation for resection of heterotopic ossification, removal of components for infection, and subsidence with loosening. The overall revision rate was 0.9%. Conclusion. For younger patients with higher functional expectations and increased lifetime risk for revision, HRA is an excellent bone preserving intervention carrying low complication rates, revision rates, and excellent patient outcomes without lifetime restrictions allowing these patients to return to activity and sport. Thus, in younger male patients with end-stage hip disease and higher demands, referral to a high-volume HRA surgeon should be considered. Cite this article: Bone Jt Open 2023;4(6):408–415


The Bone & Joint Journal
Vol. 105-B, Issue 7 | Pages 775 - 782
1 Jul 2023
Koper MC Spek RWA Reijman M van Es EM Baart SJ Verhaar JAN Bos PK

Aims. The aims of this study were to determine if an increasing serum cobalt (Co) and/or chromium (Cr) concentration is correlated with a decreasing Harris Hip Score (HHS) and Hip disability and Osteoarthritis Outcome Score (HOOS) in patients who received the Articular Surface Replacement (ASR) hip resurfacing arthroplasty (HRA), and to evaluate the ten-year revision rate and show if sex, inclination angle, and Co level influenced the revision rate. Methods. A total of 62 patients with an ASR-HRA were included and monitored yearly postoperatively. At follow-up, serum Co and Cr levels were measured and the HHS and the HOOS were scored. In addition, preoperative patient and implant variables and the need for revision surgery were recorded. We used a linear mixed model to relate the serum Co and Cr levels to different patient-reported outcome measures (PROMs). For the survival analyses we used the Kaplan-Meier and Cox regression model. Results. We found that an increase of one part per billion (ppb) in serum Co and Cr levels correlated significantly with worsening of the HHS in the following year. This significant correlation was also true for the HOOS-Pain and HOOS-quality of life sub scores. The overall ten-year survival rate in our cohort was 65% (95% confidence interval (CI) 52.5 to 77.6). Cox regression analysis showed a significant hazard ratio (HR) of 1.08 (95% CI 1.01 to 1.15; p = 0.028) for serum Co level. No significance was found with sex or inclination angle. Conclusion. This study shows that increasing serum Co and Cr levels measured in patients with an ASR-HRA are predictive for deterioration in HHS and HOOS subscales in the following year. Increasing serum Co and Cr should forewarn both surgeon and patient that there is a heightened risk of failure. Continued and regular review of patients with an ASR-HRA implant by measurement of serum Co/Cr levels and PROMs remains essential. Cite this article: Bone Joint J 2023;105-B(7):775–782


The Bone & Joint Journal
Vol. 100-B, Issue 11 | Pages 1424 - 1433
1 Nov 2018
Amstutz HC Le Duff MJ

Aims. This study presents the long-term survivorship, risk factors for prosthesis survival, and an assessment of the long-term effects of changes in surgical technique in a large series of patients treated by metal-on-metal (MoM) hip resurfacing arthroplasty (HRA). Patients and Methods. Between November 1996 and January 2012, 1074 patients (1321 hips) underwent HRA using the Conserve Plus Hip Resurfacing System. There were 787 men (73%) and 287 women (27%) with a mean age of 51 years (14 to 83). The underlying pathology was osteoarthritis (OA) in 1003 (75.9%), developmental dysplasia of the hip (DDH) in 136 (10.3%), avascular necrosis in 98 (7.4%), and other conditions, including inflammatory arthritis, in 84 (6.4%). Results. The mean follow-up time was 10.5 years (1 to 20). Using revision for any reason as the endpoint, the overall survivorship at 15 years was 89.4% (95% confidence interval (CI) 86.8 to 91.4). There was a substantial increase between the first and second generation of surgical technique (86.6% vs 90.1%; p = 0.05). Men with idiopathic OA had a 15-year survivorship of 94.5% and women, 82.2% (p = 0.001); gender was not a risk factor after stratification by component size and aetiology. Using revision for excessive wear (ion levels > 7 µg/l associated with symptoms or adverse local tissue reactions) as the endpoint, the 15-year survivorship was 98.5%. Risk factors for revision for all modes of failure were an underlying pathology of hip dysplasia, a contact patch to rim (CPR) distance of 7 mm or less, an age at surgery of 55 years or less, and a femoral component size of 46 mm or less. Specific risk factors for aseptic failure of the femoral component were early surgical technique, a cementless metaphyseal stem, and a body mass index of 24 kg/m. 2. or less. Conclusion. HRA is a viable concept; metal-on-metal bearings are well suited for this procedure when a well-designed device is properly implanted. The best results were obtained in men with OA, but survivorship was better for other underlying pathologies and for women after changes were made to the technique of implantation. Lifetime durability is a possible outcome for many patients despite a high level of activity. Cite this article: Bone Joint J 2018;100-B:1424–33


The Bone & Joint Journal
Vol. 106-B, Issue 3 Supple A | Pages 17 - 23
1 Mar 2024
LaValva SM LeBrun DG Canoles HG Ren R Padgett DE Su EP

Aims. Professional dancers represent a unique patient population in the setting of hip arthroplasty, given the high degree of hip strength and mobility required by their profession. We sought to determine the clinical outcomes and ability to return to professional dance after total hip arthroplasty (THA) or hip resurfacing arthroplasty (HRA). Methods. Active professional dancers who underwent primary THA or HRA at a single institution with minimum one-year follow-up were included in the study. Primary outcomes included the rate of return to professional dance, three patient-reported outcome measures (PROMs) (modified Harris Hip Score (mHHS), Hip disability and Osteoarthritis Outcome Score for Joint Replacement (HOOS-JR), and Lower Extremity Activity Scale (LEAS)), and postoperative complications. Results. A total of 49 hips in 39 patients (mean age 56 years (SD 13); 80% female (n = 39)) were included. Mean follow-up was 4.9 years (SD 5.1). Of these 49 hips, 37 THAs and 12 HRAs were performed. In all, 96% of hips returned to professional dance activities postoperatively. With regard to PROMs, there were statistically significant improvements in mHHS, HOOS-JR, and LEAS from baseline to ≥ one year postoperatively. There were complications in 7/49 hips postoperatively (14%), five of which required revision surgery (10%). There were no revisions for instability after the index procedure. Two complications (5.4%) occurred in hips that underwent THA compared with five (42%) after HRA (p = 0.007), though the difference by procedure was not significantly different when including only contemporary implant designs (p = 0.334). Conclusion. Active professional dancers experienced significant improvements in functional outcome scores after THA or HRA, with a 96% rate of return to professional dance. However, the revision rate at short- to mid-term follow-up highlights the challenges of performing hip arthroplasty in this demanding patient population. Further investigation is required to determine the results of THA versus HRA using contemporary implant designs in these patients. Cite this article: Bone Joint J 2024;106-B(3 Supple A):17–23


The Bone & Joint Journal
Vol. 106-B, Issue 3 Supple A | Pages 59 - 66
1 Mar 2024
Karunaseelan KJ Nasser R Jeffers JRT Cobb JP

Aims. Surgical approaches that claim to be minimally invasive, such as the direct anterior approach (DAA), are reported to have a clinical advantage, but are technically challenging and may create more injury to the soft-tissues during joint exposure. Our aim was to quantify the effect of soft-tissue releases on the joint torque and femoral mobility during joint exposure for hip resurfacing performed via the DAA. Methods. Nine fresh-frozen hip joints from five pelvis to mid-tibia cadaveric specimens were approached using the DAA. A custom fixture consisting of a six-axis force/torque sensor and motion sensor was attached to tibial diaphysis to measure manually applied torques and joint angles by the surgeon. Following dislocation, the torques generated to visualize the acetabulum and proximal femur were assessed after sequential release of the joint capsule and short external rotators. Results. Following initial exposure, the ischiofemoral ligament (7 to 8 o’clock) was the largest restrictor of exposure of the acetabulum, contributing to a mean 25% of overall external rotational restraint. The ischiofemoral ligament (10 to 12 o’clock) was the largest restrictor of exposure of the proximal femur, contributing to 25% of overall extension restraint. Releasing the short external rotators had minimal contribution in torque generated during joint exposure (≤ 5%). Conclusion. Adequate exposure of both proximal femur and acetabulum may be achieved with minimal torque by performing a full proximal circumferential capsulotomy while preserving short external rotators. The joint torque generated and exposure achieved is dependent on patient factors; therefore, some cases may necessitate further releases. Cite this article: Bone Joint J 2024;106-B(3 Supple A):59–66


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 3 | Pages 319 - 323
1 Mar 2008
Moonot P Singh PJ Cronin MD Kalairajah YE Kavanagh TG Field RE

Hip resurfacing is a bone-conserving procedure with respect to proximal femoral resection, but there is debate in the literature as to whether the same holds true for the acetabulum. We have investigated whether the Birmingham hip resurfacing conserves acetabular bone. Between 1998 and 2005, 500 Birmingham hip resurfacings were performed by two surgeons. Between 1996 and 2005 they undertook 700 primary hip replacements, with an uncemented acetabular component. These patients formed the clinical material to compare acetabular component sizing. The Birmingham hip resurfacing group comprised 350 hips in men and 150 hips in women. The uncemented total hip replacement group comprised 236 hips in men and 464 hips in women. Age- and gender-matched analysis of a cohort of patients for the sizes of the acetabular components required for the two types of replacement was also undertaken. Additionally, an analysis of the sizes of the components used by each surgeon was performed. For age-matched women, the mean outside diameter of the Birmingham hip resurfacing acetabular components was 2.03 mm less than that of the acetabular components in the uncemented total hip replacements (p < 0.0001). In similarly matched men there was no significant difference (p = 0.77). A significant difference was also found between the size of acetabular components used by the two surgeons for Birmingham hip resurfacing for both men (p = 0.0015) and women (p = 0.001). In contrast, no significant difference was found between the size of acetabular components used by the two surgeons for uncemented total hip replacement in either men or women (p = 0.06 and p = 0.14, respectively). This suggests that variations in acetabular preparation also influence acetabular component size in hip resurfacing


Bone & Joint Research
Vol. 8, Issue 10 | Pages 443 - 450
1 Oct 2019
Treacy RBC Holland JP Daniel J Ziaee H McMinn DJW

Objectives. Modern metal-on-metal (MoM) hip resurfacing arthroplasty (HRA), while achieving good results with well-orientated, well-designed components in ideal patients, is contraindicated in women, men with head size under 50 mm, or metal hypersensitivity. These patients currently have no access to the benefits of HRA. Highly crosslinked polyethylene (XLPE) has demonstrated clinical success in total hip arthroplasty (THA) and, when used in HRA, potentially reduces metal ion-related sequelae. We report the early performance of HRA using a direct-to-bone cementless mono-bloc XLPE component coupled with a cobalt-chrome femoral head, in the patient group for whom HRA is currently contraindicated. Methods. This is a cross-sectional, observational assessment of 88 consecutive metal-on-XLPE HRAs performed in 84 patients between 2015 and 2018 in three centres (three surgeons, including the designer surgeon). Mean follow-up is 1.6 years (0.7 to 3.9). Mean age at operation was 56 years (. sd. 11; 21 to 82), and 73% of implantations were in female patients. All patients were individually counselled, and a detailed informed consent was obtained prior to operation. Primary resurfacing was carried out in 85 hips, and three cases involved revision of previous MoM HRA. Clinical, radiological, and Oxford Hip Score (OHS) assessments were studied, along with implant survival. Results. There was no loss to follow-up and no actual or impending revision or reoperation. Median OHS increased from 24 (interquartile range (IQR) 20 to 28) preoperatively to 48 (IQR 46 to 48) at the latest follow-up (48 being the best possible score). Radiographs showed one patient had a head-neck junction lucency. No other radiolucency, osteolysis, component migration, or femoral neck thinning was noted. Conclusion. The results in this small consecutive cohort suggest that metal-on-monobloc-XLPE HRA is successful in the short term and merits further investigation as a conservative alternative to the current accepted standard of stemmed THA. However, we would stress that survival data with longer-term follow-up are needed prior to widespread adoption. Cite this article: R. B. C. Treacy, J. P. Holland, J. Daniel, H. Ziaee, D. J. W. McMinn. Preliminary report of clinical experience with metal-on-highly-crosslinked-polyethylene hip resurfacing. Bone Joint Res 2019;8:443–450. DOI: 10.1302/2046-3758.810.BJR-2019-0060.R1


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 8 | Pages 1110 - 1115
1 Aug 2006
Ong KL Kurtz SM Manley MT Rushton N Mohammed NA Field RE

The effects of the method of fixation and interface conditions on the biomechanics of the femoral component of the Birmingham hip resurfacing arthroplasty were examined using a highly detailed three-dimensional computer model of the hip. Stresses and strains in the proximal femur were compared for the natural femur and for the femur resurfaced with the Birmingham hip resurfacing. A comparison of cemented versus uncemented fixation showed no advantage of either with regard to bone loading. When the Birmingham hip resurfacing femoral component was fixed to bone, proximal femoral stresses and strains were non-physiological. Bone resorption was predicted in the inferomedial and superolateral bone within the Birmingham hip resurfacing shell. Resorption was limited to the superolateral region when the stem was not fixed. The increased bone strain observed adjacent to the distal stem should stimulate an increase in bone density at that location. The remodelling of bone seen during revision of failed Birmingham hip resurfacing implants appears to be consistent with the predictions of our finite element analysis


The Bone & Joint Journal
Vol. 102-B, Issue 10 | Pages 1289 - 1296
1 Oct 2020
Amstutz HC Le Duff M

Aims. Hip resurfacing arthroplasty (HRA) is typically indicated for young and active patients. Due to the longevity of arthroplasty, these patients are likely to undergo revision surgery during their lifetime. There is a paucity of information on the long-term outcome of revision surgeries performed after failed HRA. The aim of our study was to provide survivorship data as well as clinical scores after HRA revisions. Methods. A total of 42 patients (43 hips) were revised after HRA at our centre to a variety of devices, including four HRA and 39 total hip arthroplasties (THAs). In addition to perioperative complications, University of California, Los Angeles (UCLA) hip scores and 12-Item Short-Form Health Survey questionnaire (SF-12) quality of life scores were collected at follow-up visits after the primary HRA and after revision surgery. Results. The mean follow-up time after revision surgery was 8.3 years (0.3 to 19.1). The mean UCLA pain and function scores post-revision were comparable with the best scores achieved by the patients after the index HRA, but UCLA activity scores were lower after revision. SF-12 physical component scores were comparable between timepoints, but the mental component score decreased after revision. Six patients underwent unilateral re-revision surgery at a mean follow-up time of 7.8 years (0.3 to 13.7). Using the time to any re-revision as endpoint, the Kaplan-Meier survivorship was 85.3% at 13 years. Conclusion. Patients undergoing revision after HRA can expect to achieve function and quality of life similar to their best after their primary surgery, while the risk of re-revision is low. Cite this article: Bone Joint J 2020;102-B(10):1289–1296


The Bone & Joint Journal
Vol. 98-B, Issue 1_Supple_A | Pages 10 - 13
1 Jan 2016
Brooks PJ

Hip resurfacing has been proposed as an alternative to traditional total hip arthroplasty in young, active patients. Much has been learned following the introduction of metal-on-metal resurfacing devices in the 1990s. The triad of a well-designed device, implanted accurately, in the correct patient has never been more critical than with these implants. . Following Food and Drug Administration approval in 2006, we studied the safety and effectiveness of one hip resurfacing device (Birmingham Hip Resurfacing) at our hospital in a large, single-surgeon series. We report our early to mid–term results in 1333 cases followed for a mean of 4.3 years (2 to 5.7) using a prospective, observational registry. The mean patient age was 53.1 years (12 to 84); 70% were male and 91% had osteoarthritis. Complications were few, including no dislocations, no femoral component loosening, two femoral neck fractures (0.15%), one socket loosening (0.08%), three deep infections (0.23%), and three cases of metallosis (0.23%). There were no destructive pseudotumours. Overall survivorship at up to 5.7 years was 99.2%. Aseptic survivorship in males under the age of 50 was 100%. We believe this is the largest United States series of a single surgeon using a single resurfacing system. Cite this article: Bone Joint J 2016;98-B (1 Suppl A):10–13


The Bone & Joint Journal
Vol. 103-B, Issue 7 Supple B | Pages 25 - 32
1 Jul 2021
Amstutz HC Le Duff MJ

Aims. Adverse local tissue reactions associated with abnormal wear considerably slowed down the general use of metal-on-metal (MoM) hip resurfacing arthroplasty (HRA), now limited to a few specialized centres. In this study, we provide the clinical results of 400 consecutive MoM HRAs implanted more than 20 years ago in one such centre. Methods. A total of 355 patients (400 hips) were treated with Conserve Plus HRA between November 1996 and November 2000. There were 96 female (27%) and 259 male patients (73%). Their mean age was 48.2 years (SD 10.9). The University of California, Los Angeles (UCLA) hip scores and 12-item Short Form Survey (SF-12) quality of life scores were reported. Survivorship was assessed using Kaplan-Meier analyses. Results. The mean follow-up was 16.5 years (0.1 to 24.0), including 34 patients (37 hips) who died. The mean UCLA hip scores were 9.3 (2 to 10), 9.1 (3 to 10), 9.0 (3 to 10), and 6.9 (2 to 10) for pain, walking, function, and activity, respectively. The mean SF-12 scores were 48.4 (16.0 to 62.1) for the physical component and 48.5 (10.5 to 66.5) for the mental component, and did not differ from those of the general population of the USA. A total of 60 hips in 55 patients were revised. Using revision for any indication as the endpoint, the Kaplan-Meier survivorship was 83.5% at 20 years. A diagnosis of developmental dysplasia (hazard ratio (HR) 2.199 (95% confidence interval (CI) 1.140 to 4.239); p = 0.019) and a low BMI (HR 0.931 (95% CI 0.873 to 0.994); p = 0.032) were risk factors for revision. Female sex was a risk factor only because of hip dysplasia and small component size. There were no cases of metal sensitivity associated with revision surgery. Radiological analysis showed persistent fixation in all but one hip. Conclusion. The 83.5% 20-year survivorship of this initial series surpasses that of total hip arthroplasties in use 20 years ago in these young patients, suggesting satisfactory lifelong durability of the device for almost all of the remaining patients. Cite this article: Bone Joint J 2021;103-B(7 Supple B):25–32


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 10 | Pages 1344 - 1350
1 Oct 2010
Carrothers AD Gilbert RE Jaiswal A Richardson JB

Despite the increasing interest and subsequent published literature on hip resurfacing arthroplasty, little is known about the prevalence of its complications and in particular the less common modes of failure. The aim of this study was to identify the prevalence of failure of hip resurfacing arthroplasty and to analyse the reasons for it. From a multi-surgeon series (141 surgeons) of 5000 Birmingham hip resurfacings we have analysed the modes, prevalence, gender differences and times to failure of any hip requiring revision. To date 182 hips have been revised (3.6%). The most common cause for revision was a fracture of the neck of the femur (54 hips, prevalence 1.1%), followed by loosening of the acetabular component (32 hips, 0.6%), collapse of the femoral head/avascular necrosis (30 hips, 0.6%), loosening of the femoral component (19 hips, 0.4%), infection (17 hips, 0.3%), pain with aseptic lymphocytic vascular and associated lesions (ALVAL)/metallosis (15 hips, 0.3%), loosening of both components (five hips, 0.1%), dislocation (five hips, 0.1%) and malposition of the acetabular component (three hips, 0.1%). In two cases the cause of failure was unknown. Comparing men with women, we found the prevalence of revision to be significantly higher in women (women = 5.7%; men = 2.6%, p < 0.001). When analysing the individual modes of failure women had significantly more revisions for loosening of the acetabular component, dislocation, infection and pain/ALVAL/metallosis (p < 0.001, p = 0.004, p = 0.008, p = 0.01 respectively). The mean time to failure was 2.9 years (0.003 to 11.0) for all causes, with revision for fracture of the neck of the femur occurring earlier than other causes (mean 1.5 years, 0.02 to 11.0). There was a significantly shorter time to failure in men (mean 2.1 years, 0.4 to 8.7) compared with women (mean 3.6 years, 0.003 to 11.0) (p < 0.001)


The Bone & Joint Journal
Vol. 105-B, Issue 5 | Pages 467 - 470
1 May 2023
McBryde CW Prakash R Haddad FS


The Bone & Joint Journal
Vol. 97-B, Issue 5 | Pages 617 - 622
1 May 2015
Haddad FS Konan S Tahmassebi J

The aim of this study was to evaluate the ten-year clinical and functional outcome of hip resurfacing and to compare it with that of cementless hip arthroplasty in patients under the age of 55 years. . Between 1999 and 2002, 80 patients were enrolled into the study: 24 were randomised (11 to hip resurfacing, 13 to total hip arthroplasty), 18 refused hip resurfacing and chose cementless total hip arthroplasty with a 32 mm bearing, and 38 insisted on resurfacing. The mean follow-up for all patients was 12.1 years (10 to 14). Patients were assessed clinically and radiologically at one year, five years and ten years. Outcome measures included EuroQol EQ5D, Oxford, Harris hip, University of California Los Angeles and University College Hospital functional scores. . No differences were seen between the two groups in the Oxford or Harris hip scores or in the quality of life scores. Despite a similar aspiration to activity pre-operatively, a higher proportion of patients with a hip resurfacing were running and involved in sport and heavy manual labour after ten years. We found significantly higher function scores in patients who had undergone hip resurfacing than in those with a cementless hip arthroplasty at ten years. This suggests a functional advantage for hip resurfacing. There were no other attendant problems. Cite this article: Bone Joint J 2015; 97-B:617–22


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 8 | Pages 1072 - 1078
1 Aug 2010
Grammatopoulos G Pandit H Glyn-Jones S McLardy-Smith P Gundle R Whitwell D Gill HS Murray DW

Pseudotumours are a rare complication of hip resurfacing. They are thought to be a response to metal debris which may be caused by edge loading due to poor orientation of the acetabular component. Our aim was to determine the optimal acetabular orientation to minimise the risk of pseudotumour formation. We matched 31 hip resurfacings revised for pseudotumour formation with 58 controls who had a satisfactory outcome from this procedure. The radiographic inclination and anteversion angles of the acetabular component were measured on anteroposterior radiographs of the pelvis using Einzel-Bild-Roentgen-Analyse software. The mean inclination angle (47°, 10° to 81°) and anteversion angle (14°, 4° to 34°) of the pseudotumour cases were the same (p = 0.8, p = 0.2) as the controls, 46° (29° to 60°) and 16° (4° to 30°) respectively, but the variation was greater. Assuming an accuracy of implantation of ± 10° about a target position, the optimal radiographic position was found to be approximately 45° of inclination and 20° of anteversion. The incidence of pseudotumours inside the zone was four times lower (p = 0.007) than outside the zone. In order to minimise the risk of pseudotumour formation we recommend that surgeons implant the acetabular component at an inclination of 45° (± 10) and anteversion of 20° (± 10) on post-operative radiographs. Because of differences between the radiographic and the operative angles, this may be best achieved by aiming for an inclination of 40° and an anteversion of 25°


The Bone & Joint Journal
Vol. 98-B, Issue 7 | Pages 901 - 909
1 Jul 2016
Amstutz HC Le Duff MJ

Aims. Hip resurfacing arthroplasty (HRA) is an alternative to conventional total hip arthroplasty for patients with osteonecrosis (ON) of the femoral head. Our aim was to report the long-term outcome of HRA, which is not currently known. Patients and Methods. Long-term survivorship, clinical scores and radiographic results for 82 patients (99 hips) treated with HRA for ON over a period of 18 years were reviewed retrospectively. The mean age of the 67 men and 15 women at the time of surgery was 40.8 years (14 to 64). Patients were resurfaced regardless of the size of the osteonecrotic lesion. Results. The mean clinical follow-up was 10.8 years (2 to 18). The mean University of California, Los Angeles hip scores at the last follow-up were 9.3, 9.4, 9.2 and 6.8 for pain, walking, function and activity, respectively. A total of six hips underwent revision surgery, four for loosening of the femoral component and two for loosening of the acetabular component. Using any revision as an end point, the 15-year Kaplan-Meier survivorship was 90.3%. There were no wear-related failures. There were no femoral failures among the hips reconstructed with a cemented metaphyseal stem. A total of five hips showed narrowing of the femoral neck; all stabilised and remain asymptomatic, 21 showed signs of femoral neck impingement. Conclusion. To our knowledge, this is the first report of a series of HRA performed for ON with 15-year survivorship. Our data confirm that patients with advanced stages of ON of the femoral head are excellent candidates for HRA. Cite this article: Bone Joint J 2016;98-B:901–9


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 3 | Pages 307 - 314
1 Mar 2011
Matthies A Underwood R Cann P Ilo K Nawaz Z Skinner J Hart AJ

This study compared component wear rates and pre-revision blood metal ions levels in two groups of failed metal-on-metal hip arthroplasties: hip resurfacing and modular total hip replacement (THR). There was no significant difference in the median rate of linear wear between the groups for both acetabular (p = 0.4633) and femoral (p = 0.0872) components. There was also no significant difference in the median linear wear rates when failed hip resurfacing and modular THR hips of the same type (ASR and Birmingham hip resurfacing (BHR)) were compared. Unlike other studies of well-functioning hips, there was no significant difference in pre-revision blood metal ion levels between hip resurfacing and modular THR. Edge loading was common in both groups, but more common in the resurfacing group (67%) than in the modular group (57%). However, this was not significant (p = 0.3479). We attribute this difference to retention of the neck in resurfacing of the hip, leading to impingement-type edge loading. This was supported by visual evidence of impingement on the femur. These findings show that failed metal-on-metal hip resurfacing and modular THRs have similar component wear rates and are both associated with raised pre-revision blood levels of metal ions


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 11 | Pages 1509 - 1514
1 Nov 2010
Smolders JMH Hol A Rijnders T van Susante JLC

We undertook a randomised prospective follow-up study of changes in peri-prosthetic bone mineral density (BMD) after hip resurfacing and compared them with the results after total hip replacement. A total of 59 patients were allocated to receive a hip resurfacing (n = 29) or an uncemented distally fixed total hip replacement (n = 30). The BMD was prospectively determined in four separate regions of interest of the femoral neck and in the calcar region corresponding to Gruen zone 7 for the hip resurfacing group and compared only to the calcar region in the total hip replacement group. Standardised measurements were performed pre-operatively and after three, six and 12 months. The groups were well matched in terms of gender distribution and mean age. The mean BMD in the calcar region increased after one year to 105.2% of baseline levels in the resurfaced group compared with a significant decrease to 82.1% in the total hip replacement group (p < 0.001) by 12 months. For the resurfaced group, there was a decrease in bone density in all four regions of the femoral neck at three months which did not reach statistical significance and was followed by recovery to baseline levels after 12 months. Hip resurfacing did indeed preserve BMD in the inferior femoral neck. In contrast, a decrease in the mean BMD in Gruen zone 7 followed uncemented distally fixed total hip replacement. Long term follow-up studies are necessary to see whether this benefit in preservation of BMD will be clinically relevant at future revision surgery


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 6 | Pages 746 - 754
1 Jun 2012
Jameson SS Baker PN Mason J Porter ML Deehan DJ Reed MR

Modern metal-on-metal hip resurfacing has been widely performed in the United Kingdom for over a decade. However, the literature reports conflicting views of the benefits: excellent medium- to long-term results with some brands in specific subgroups, but high failure rates and local soft-tissue reactions in others. The National Joint Registry for England and Wales (NJR) has collected data on all hip resurfacings performed since 2003. This retrospective cohort study recorded survival time to revision from a resurfacing procedure, exploring risk factors independently associated with failure. All patients with a primary diagnosis of osteoarthritis who underwent resurfacing between 2003 and 2010 were included in the analyses. Cox’s proportional hazard models were used to analyse the extent to which the risk of revision was related to patient, surgeon and implant covariates. A total of 27 971 hip resurfacings were performed during the study period, of which 1003 (3.59%) underwent revision surgery. In the final adjusted model, we found that women were at greater risk of revision than men (hazard ratio (HR) = 1.30, p = 0.007), but the risk of revision was independent of age. Of the implant-specific predictors, five brands had a significantly greater risk of revision than the Birmingham Hip Resurfacing (BHR) (ASR: HR = 2.82, p < 0.001, Conserve: HR = 2.03, p < 0.001, Cormet: HR = 1.43, p = 0.001, Durom: HR = 1.67, p < 0.001, Recap: HR = 1.58, p = 0.007). Smaller femoral head components were also significantly more likely to require revision (≤ 44 mm: HR = 2.14, p < 0.001, 45 to 47 mm: HR = 1.48, p = 0.001) than medium or large heads, as were operations performed by low-volume surgeons (HR = 1.36, p <  0.001). Once these influences had been removed, in 4873 male patients < 60 years old undergoing resurfacing with a BHR, the five-year estimated risk of revision was 1.59%. In summary, after adjustment for a range of covariates we found that there were significant differences in the rate of failure between brands and component sizes. Younger male patients had good five-year implant survival when the BHR was used


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 6 | Pages 787 - 793
1 Jun 2010
Steffen RT Athanasou NA Gill HS Murray DW

The cause of fracture of the femoral neck after hip resurfacing is poorly understood. In order to evaluate the role of avascular necrosis we compared 19 femoral heads retrieved at revision for fracture of the femoral neck and 13 retrieved for other reasons. We developed a new technique of assessing avascular necrosis in the femoral head by determining the percentage of empty osteocyte lacunae present. Femoral heads retrieved as controls at total hip replacement for osteoarthritis and avascular necrosis had 9% (. sd. 4; n = 13) and 85% (. sd. 5; n = 10, p < 0.001) empty lacunae, respectively. In the fracture group the percentage of empty lacunae was 71% (. sd. 22); in the other group it was 21% (. sd. 13). The differences between the groups were highly significant (p < 0.001). We conclude that fracture after resurfacing of the hip is associated with a significantly greater percentage of empty osteocyte lacunae within the trabecular bone. This indicates established avascular necrosis and suggests that damage to the blood supply at the time of surgery is a potent risk factor for fracture of the femoral neck after hip resurfacing


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 1 | Pages 27 - 33
1 Jan 2011
Treacy RBC McBryde CW Shears E Pynsent PB

We report the survival, radiological and functional outcomes of a single surgeon series of his first 144 consecutive Birmingham hip resurfacing procedures (130 patients) at a minimum of ten years. There were ten revisions during this time. Although no patients were lost to follow-up some did not complete the scoring assessment or undergo radiological assessment at ten years. The ten-year survival for male patients was 98.0% (95% confidence interval 95.2 to 100). The ten-year survival for the total cohort with aseptic revision as the endpoint was 95.5% (95% confidence interval 91.8 to 99.0) and including revisions for sepsis was 93.5% (95% confidence interval 89.2 to 97.6). The median modified Oxford hip score at ten years was 4.2% (interquartile range 0 to 19) and the median University of California, Los Angeles score was 7.0 (interquartile range 5.0 to 8.0). This study confirms the midterm reports that metal-on-metal hip resurfacing using the Birmingham Hip provides a durable alternative to total hip replacement, particularly in younger male patients wishing to maintain a high level of function, with low risk of revision for at least ten years


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 10 | Pages 1287 - 1295
1 Oct 2009
Langton DJ Sprowson AP Joyce TJ Reed M Carluke I Partington P Nargol AVF

There have been no large comparative studies of the blood levels of metal ions after implantation of commercially available hip resurfacing devices which have taken into account the effects of femoral size and inclination and anteversion of the acetabular component. We present the results in 90 patients with unilateral articular surface replacement (ASR) hip resurfacings (mean time to blood sampling 26 months) and 70 patients with unilateral Birmingham Hip Resurfacing (BHR) implants (mean time 47 months). The whole blood and serum chromium (Cr) and cobalt (Co) concentrations were inversely related to the size of the femoral component in both groups (p < 0.05). Cr and Co were more strongly influenced by the position of the acetabular component in the case of the ASR, with an increase in metal ions observed at inclinations > 45° and anteversion angles of < 10° and > 20°. These levels were only increased in the BHR group when the acetabular component was implanted with an inclination > 55°. A significant relationship was identified between the anteversion of the BHR acetabular component and the levels of Cr and Co (p < 0.05 for Co), with an increase observed at anteversion angles < 10° and > 20°. The median whole blood and serum Cr concentrations of the male ASR patients were significantly lower than those of the BHR men (p < 0.001). This indicates that reduced diametral clearance may equate to a reduction in metal ion concentrations in larger joints with satisfactory orientation of the acetabular component


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 3 | Pages 315 - 321
1 Mar 2012
Coulter G Young DA Dalziel RE Shimmin AJ

We report the findings of an independent review of 230 consecutive Birmingham hip resurfacings (BHRs) in 213 patients (230 hips) at a mean follow-up of 10.4 years (9.6 to 11.7). A total of 11 hips underwent revision; six patients (six hips) died from unrelated causes; and 13 patients (16 hips) were lost to follow-up. The survival rate for the whole cohort was 94.5% (95% confidence interval (CI) 90.1 to 96.9). The survival rate in women was 89.1% (95% CI 79.2 to 94.4) and in men was 97.5% (95% CI 92.4 to 99.2). Women were 1.4 times more likely to suffer failure than men. For each millimetre increase in component size there was a 19% lower chance of a failure. The mean Oxford hip score was 45.0 (median 47.0, 28 to 48); mean University of California, Los Angeles activity score was 7.4 (median 8.0, 3 to 9); mean patient satisfaction score was 1.4 (median 1.0, 0 to 9). A total of eight hips had lysis in the femoral neck and two hips had acetabular lysis. One hip had progressive radiological changes around the peg of the femoral component. There was no evidence of progressive neck narrowing between five and ten years. Our results confirm that BHR provides good functional outcome and durability for men, at a mean follow-up of ten years. We are now reluctant to undertake hip resurfacing in women with this implant


Bone & Joint 360
Vol. 3, Issue 1 | Pages 40 - 41
1 Feb 2014
Ivory J

Metal-on-metal (MoM) hip resurfacing was developed in the 1990s by surgeons in Birmingham, UK, as a surgical solution to the problem of osteoarthritis in younger, more active patients. Early results were promising and the procedure gained in popularity. However, adverse reports of soft-tissue reaction and failure started to appear from 2008 onwards. Surgeons may be asked to write medico-legal reports on the surgical aspects of an individual case for claimant lawyers or in defence for the NHSLA or indemnity insurers. The purpose of this article is to cover some of the aspects of the operation that may be considered in such medico-legal reports


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 2 | Pages 163 - 166
1 Feb 2005
Loughead JM Chesney D Holland JP McCaskie AW

Hip resurfacing is being performed more frequently in the United Kingdom. The possible benefits include more accurate restoration of leg length, femoral offset and femoral anteversion than occurs after total hip arthroplasty (THA). We compared anteroposterior radiographs from 26 patients who had undergone hybrid THA (uncemented cup/cemented stem), with 28 who had undergone Birmingham Hip Resurfacing arthroplasty (BHR). We measured the femoral offset, femoral length, acetabular offset and acetabular height with reference to the normal contralateral hip. The data were analysed by paired t-tests. There was a significant reduction in femoral offset (p = 0.0004) and increase in length (p = 0.001) in the BHR group. In the THA group, there was a significant reduction in acetabular offset (p = 0.0003), but femoral offset and overall hip length were restored accurately. We conclude that hip resurfacing does not restore hip mechanics as accurately as THA


The Bone & Joint Journal
Vol. 101-B, Issue 11 | Pages 1423 - 1430
1 Nov 2019
Wiik AV Lambkin R Cobb JP

Aims. The aim of this study was to assess the functional gain achieved following hip resurfacing arthroplasty (HRA). Patients and Methods. A total of 28 patients (23 male, five female; mean age, 56 years (25 to 73)) awaiting Birmingham HRA volunteered for this prospective gait study, with an age-matched control group of 26 healthy adults (16 male, ten female; mean age, 56 years (33 to 84)). The Oxford Hip Score (OHS) and gait analysis using an instrumented treadmill were used preoperatively and more than two years postoperatively to measure the functional change attributable to the intervention. Results. The mean OHS improved significantly from 27 to 46 points (p < 0.001) at a mean of 29 months (12 to 60) after HRA. The mean metal ion levels at a mean 32 months (13 to 60) postoperatively were 1.71 (0.77 to 4.83) µg/l (ppb) and 1.77 (0.68 to 4.16) µg/l (ppb) for cobalt and chromium, respectively. When compared with healthy controls, preoperative patients overloaded the contralateral good hip, limping significantly. After HRA, patients walked at high speeds, with symmetrical gait, statistically indistinguishable from healthy controls over almost all characteristics. The control group could only be distinguished by an increased push-off force at higher speeds, which may reflect the operative approach. Conclusion. Patients undergoing HRA improved their preoperative gait pattern of a significant limp to a symmetrical gait at high speeds and on inclines, almost indistinguishable from normal controls. HRA with an approved device offers substantial functional gains, almost indistinguishable from healthy controls. Cite this article: Bone Joint J 2019;101-B:1423–1430


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 11 | Pages 1431 - 1438
1 Nov 2007
Hing CB Back DL Bailey M Young DA Dalziel RE Shimmin AJ

We report an independent prospective review of the first 230 Birmingham hip resurfacings in 212 patients at a mean follow-up of five years (4 to 6). Two patients, one with a loose acetabular component and the other with suspected avascular necrosis of the femoral head, underwent revision. There were two deaths from unrelated causes and one patient was lost to follow-up. The survivorship with the worst-case scenario was 97.8% (95% confidence interval 95.8 to 99.5). The mean Harris hip score improved significantly (paired t-test, p < 0.05) from 62.54 (8 to 92) pre-operatively to 97.7 (61 to 100) at a mean of three years (2.1 to 4.3), then deteriorated slightly to a mean of 95.2 (47 to 100) at a mean of five years. The mean flexion improved from 91.5° (25° to 140°) to 110.4° (80° to 145°) at a mean of three years with no further improvement at five years (111.2°; 70° to 160°). On radiological review at five years, one patient had a progressive lucent line around the acetabular component and six had progressive lucent lines around the femoral component. A total of 18 femoral components (8%) had migrated into varus and those with lucent lines present migrated a mean of 3.8° (1.02° to 6.54°) more than the rest. Superolateral notching of the femoral neck and reactive sclerosis at the tip of the peg of the femoral component were associated with the presence of lucent lines (chi-squared test, p < 0.05), but not with migration of the femoral component, and are of unknown significance. Our results with the Birmingham hip resurfacing continue to be satisfactory at a mean follow-up of five years


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 12 | Pages 1648 - 1653
1 Dec 2010
Cordingley R Kohan L Ben-Nissan B

The major advantage of hip resurfacing is the decreased amount of bone resection compared with a standard total hip replacement. Fracture of the femoral neck is the most common early complication and poor bone quality is a major risk factor. We undertook a prospective consecutive case control study examining the effect of bone mineral density changes in patients undergoing hip resurfacing surgery. A total of 423 patients were recruited with a mean age of 54 years (24 to 87). Recruitment for this study was dependent on pre-operative bilateral femoral bone mineral density results not being osteoporotic. The operated and non-operated hips were assessed. Bone mineral density studies were repeated over a two-year period. The results showed no significant deterioration in the bone mineral density in the superolateral region in the femoral neck, during that period. These findings were in the presence of a markedly increased level of physical activity, as measured by the short-form 36 health survey physical function score


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 4 | Pages 483 - 487
1 Apr 2012
Prosser GH Shears E O’Hara JN

The painful subluxed or dislocated hip in adults with cerebral palsy presents a challenging problem. Prosthetic dislocation and heterotopic ossification are particular concerns. We present the first reported series of 19 such patients (20 hips) treated with hip resurfacing and proximal femoral osteotomy. The pre-operative Gross Motor Function Classification System (GMFCS) was level V in 13 (68%) patients, level IV in three (16%), level III in one (5%) and level II in two (11%). The mean age at operation was 37 years (13 to 57). The mean follow-up was 8.0 years (2.7 to 11.6), and 16 of the 18 (89%) contactable patients or their carers felt that the surgery had been worthwhile. Pain was relieved in 16 of the 18 surviving hips (89%) at the last follow-up, and the GMFCS level had improved in seven (37%) patients. There were two (10%) early dislocations; three hips (15%) required revision of femoral fixation, and two hips (10%) required revision, for late traumatic fracture of the femoral neck and extra-articular impingement, respectively. Hence there were significant surgical complications in a total of seven hips (35%). No hips required revision for instability, and there were no cases of heterotopic ossification. We recommend hip resurfacing with proximal femoral osteotomy for the treatment of the painful subluxed or dislocated hip in patients with cerebral palsy


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 1 | Pages 9 - 15
1 Jan 2007
Beaulé PE Harvey N Zaragoza E Le Duff MJ Dorey FJ

Because the femoral head/neck junction is preserved in hip resurfacing, patients may be at greater risk of impingement, leading to abnormal wear patterns and pain. We assessed femoral head/neck offset in 63 hips undergoing metal-on-metal hip resurfacing and in 56 hips presenting with non-arthritic pain secondary to femoroacetabular impingement. Most hips undergoing resurfacing (57%; 36) had an offset ratio ≤ 0.15 pre-operatively and required greater correction of offset at operation than the rest of the group. In the non-arthritic hips the mean offset ratio was 0.137 (0.04 to 0.23), with the offset ratio correlating negatively to an increasing α angle. An offset ratio ≤ 0.15 had a 9.5-fold increased relative risk of having an α angle ≥ 50.5°. Most hips undergoing resurfacing have an abnormal femoral head/neck offset, which is best assessed in the sagittal plane


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 2 | Pages 167 - 170
1 Feb 2005
Treacy RBC McBryde CW Pynsent PB

We report the survival at five years of 144 consecutive metal-on-metal resurfacings of the hip implanted between August 1997 and May 1998. Failure was defined as revision of either the acetabular or femoral component for any reason during the study period. The survival at the end of five years was 98% overall and 99% for aseptic revisions only. The mean age of the patients at implantation was 52.1 years. Three femoral components failed during the first two years, two were infected and one fractured. A single stage revision was carried out in each case. No other revisions were performed or are impending. No patients were lost to follow-up. Four died from unrelated causes during the study period. This study confirms that hip resurfacing using a metal-on-metal bearing of known provenance can provide a solution in the medium term for the younger more active adult who requires surgical intervention for hip disease


Bone & Joint Research
Vol. 1, Issue 5 | Pages 86 - 92
1 May 2012
Amarasekera HW Roberts P Costa ML Parsons N Achten J Griffin DR Williams NR

Objectives. To study the vascularity and bone metabolism of the femoral head/neck following hip resurfacing arthroplasty, and to use these results to compare the posterior and the trochanteric-flip approaches. Methods. In our previous work, we reported changes to intra-operative blood flow during hip resurfacing arthroplasty comparing two surgical approaches. In this study, we report the vascularity and the metabolic bone function in the proximal femur in these same patients at one year after the surgery. Vascularity and bone function was assessed using scintigraphic techniques. Of the 13 patients who agreed to take part, eight had their arthroplasty through a posterior approach and five through a trochanteric-flip approach. Results. One year after surgery, we found no difference in the vascularity (vascular phase) and metabolic bone function (delayed phase) at the junction of the femoral head/neck between the two groups of patients. Higher radiopharmaceutical uptake was found in the region of the greater trochanter in the trochanteric-flip group, related to the healing osteotomy. Conclusions. Our findings using scintigraphic techniques suggest that the greater intra-operative reduction in blood flow to the junction of the femoral head/neck, which is seen with the posterior approach compared with trochanteric flip, does not result in any difference in vascularity or metabolic bone function one year after surgery


The Bone & Joint Journal
Vol. 95-B, Issue 8 | Pages 1045 - 1051
1 Aug 2013
Arthroplasty Society C

The purpose of this study was twofold: first, to determine whether the five-year results of hip resurfacing arthroplasty (HRA) in Canada justified the continued use of HRA; and second, to identify whether greater refinement of patient selection was warranted. This was a retrospective cohort study that involved a review of 2773 HRAs performed between January 2001 and December 2008 at 11 Canadian centres. Cox’s proportional hazards models were used to analyse the predictors of failure of HRA. Kaplan–Meier survival analysis was performed to predict the cumulative survival rate at five years. The factors analysed included age, gender, body mass index, pre-operative hip pathology, surgeon’s experience, surgical approach, implant sizes and implant types. The most common modes of failure were also analysed. The 2773 HRAs were undertaken in 2450 patients: 2127 in men and 646 in women. The mean age at operation was 50.5 years (. sd. 8.72; 18 to 82) and mean follow-up was 3.4 years (. sd. 2.1; 2.0 to 10.1). At the last follow-up a total of 101 HRAs (3.6%) required revision. Using revision for all causes of failure as the endpoint, Kaplan–Meier survival analysis showed a cumulative survival of 96.4% (95% confidence interval (CI) 96.1 to 96.9) at five years. With regard to gender, the five-year overall survival was 97.4% in men (95% CI 97.1 to 97.7) and 93.6% in women (95% CI 92.6 to 94.6). Female gender, smaller femoral components, specific implant types and a diagnosis of childhood hip problems were associated with higher rates of failure. The most common cause of failure was fracture of the femoral neck, followed by loosening of the femoral component. The failure rates of HRA at five years justify the ongoing use of this technique in men. Female gender is an independent predictor of failure, and a higher failure rate at five years in women leads the authors to recommend this technique only in exceptional circumstances for women. . Cite this article: Bone Joint J 2013;95-B:1044–50


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 4 | Pages 545 - 551
1 Apr 2009
Schnurr C Nessler J Meyer C Schild HH Koebke J König DP

The aim of our study was to investigate whether placing of the femoral component of a hip resurfacing in valgus protected against spontaneous fracture of the femoral neck. We performed a hip resurfacing in 20 pairs of embalmed femora. The femoral component was implanted at the natural neck-shaft angle in the left femur and with a 10° valgus angle on the right. The bone mineral density of each femur was measured and CT was performed. Each femur was evaluated in a materials testing machine using increasing cyclical loads. In specimens with good bone quality, the 10° valgus placement of the femoral component had a protective effect against fractures of the femoral neck. An adverse effect was detected in osteoporotic specimens. When resurfacing the hip a valgus position of the femoral component should be achieved in order to prevent fracture of the femoral neck. Patient selection remains absolutely imperative. In borderline cases, measurement of bone mineral density may be indicated


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 10 | Pages 1281 - 1286
1 Oct 2009
Olsen M Davis ET Chiu M Gamble P Tumia N Boyle RA Schemitsch EH

The computed neck-shaft angle and the size of the femoral component were recorded in 100 consecutive hip resurfacings using imageless computer-navigation and compared with the angle measured before operation and with actual component implanted. The reliability of the registration was further analysed using ten cadaver femora. The mean absolute difference between the measured and navigated neck-shaft angle was 16.3° (0° to 52°). Navigation underestimated the measured neck-shaft angle in 38 patients and the correct implant size in 11. Registration of the cadaver femora tended to overestimate the correct implant size and provided a low level of repeatability in computing the neck-shaft angle. Prudent pre-operative planning is advisable for use in conjunction with imageless navigation since misleading information may be registered intraoperatively, which could lead to inappropriate sizing and positioning of the femoral component in hip resurfacing


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 18 - 18
1 Jan 2013
Wiik A Tankard S Lewis A Krishnan S Amis A Cobb J
Full Access

Background. High functional aspirations and an active ageing population equate to a growing number of patients awaiting hip arthroplasty demanding superior biomechanical function. The purpose of this study was to compare the biomechanics of top walking speed between two commonly used hip arthroplasty procedures to determine if a performance advantage existed. Methods. A retrospective comparative study was performed using sixty-seven subjects, twenty-two subjects in both hip resurfacing and total hip arthroplasty groups along with twenty-three healthy controls. All arthroplasty subjects were recruited based on high psychometric scoring and had been performed through a posterior approach, and had been discharged from follow-up. On an instrumented treadmill each subject was measured by a researcher blinded to which procedure that patient had undergone. After a six minute acclimatization period, the speed was increased incrementally until top walking performance had been attained. At all increments, ground reaction forces and temporospatial measurements were collected. Results. The two arthroplasty groups were well matched demographically, with no significant differences with regards to age, sex, height, BMI and pre-operative radiological severity. Treadmill temporospatial analysis demonstrated significant differences between the two groups. The hip resurfacing group were able to walk statistically faster (p=0.023) with an increased step length(p=0.041). The top walking speed mean of 2.06m/sec by the resurfacing almost matched the healthy controls. Assessing ground reaction forces and symmetry also demonstrated hip resurfacing was superior (Graph 1). [Graph 1: Mean Gait Biomechanics at Top Speed]. Conclusion. This study is the first to focus on high end performance following hip arthroplasty, encouraging patients to achieve as high a speed as they comfortably could. The total hip arthroplasty group walked nine percent faster than the previously published top speed of 1.73m/sec, however the resurfacings still walked ten percent faster, matching the normal controls for speed and step length


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 3 | Pages 324 - 329
1 Mar 2005
Back DL Dalziel R Young D Shimmin A

We describe the experience with the first consecutive 230 Birmingham hip resurfacings at our centre. At a mean follow-up of three years (25 to 52 months) survivorship was 99.14% with revision in one patient for a loose acetabular component and one death from unrelated causes. One patient developed a fracture of the femoral neck at six weeks which united unremarkably after a period of non-weight-bearing. The Harris hip score improved from a mean of 62.54 (8 to 92) to 97.74 (61 to 100). The mean flexion improved from 91.52° (25 to 140) to 110.41° (80 to 145). Most patients (97%) considered the outcome to be good or excellent. Our preliminary experience with this implant is encouraging and the results are superior to the earlier generation of resurfacings for the same length of follow-up


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 2 | Pages 158 - 162
1 Feb 2005
Itayem R Arndt A Nistor L McMinn D Lundberg A

The Birmingham hip resurfacing metal-on-metal arthroplasty was introduced in 1997 and has shown promising short- to mid-term results. We used radiostereophotogrammetric analysis (RSA) to study the stability of 20 resurfacing arthroplasties over a follow-up period of 24 months. Radiological examinations for RSA were performed immediately after surgery and at two, six, 12 and 24 months after operation. Precision and detection of migration thresholds (non-zero movement) were calculated. All the results corresponded well to those found in similar experimental arrangements with standard hip prostheses. Migration of the cup and vertical and mediolateral migration of the head were calculated. The values were low at two years compared with those of earlier studies of cemented femoral components in conventional total hip replacements indicating that there was no evidence of excessive early migration or loosening of the components


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 11 | Pages 1468 - 1474
1 Nov 2005
Steffen RT Smith SR Urban JPG McLardy-Smith P Beard DJ Gill HS Murray DW

We inserted an electrode up the femoral neck into the femoral head of ten patients undergoing a metal-on-metal hip resurfacing arthroplasty through a posterior surgical approach and measured the oxygen concentration during the operation. In every patient the blood flow was compromised during surgery, but the extent varied. In three patients, the oxygen concentration was zero at the end of the procedure. The surgical approach caused a mean 60% drop (p < 0.005) in oxygen concentration while component insertion led to a further 20% drop (p < 0.04). The oxygen concentration did not improve significantly on wound closure. This study demonstrates that during hip resurfacing arthroplasty, patients experience some compromise to their femoral head blood supply and some have complete disruption


The Bone & Joint Journal
Vol. 99-B, Issue 7 | Pages 865 - 871
1 Jul 2017
Amstutz HC Le Duff MJ Bhaurla SK

Aims. A contact patch to rim (CPR) distance of < 10 mm has been associated with edge-loading and excessive wear. However, not all arthroplasties with a low CPR distance show problems with wear. Therefore, CPR distance may not be the only variable affecting the post-operative metal ion concentrations. Patients and Methods. We used multiple logistic regression to determine what variables differed between the patients who had high and low cobalt (CoS) and chromium (CrS) serum ion concentrations within a cohort of patients with low (< 10 mm) CPR distances. A total of 56 patients treated with unilateral hip resurfacing arthroplasty (HRA) had CoS and CrS ion studies performed more than one year after surgery. The mean age of the patients at the time of surgery was 51.7 years (29 to 70), with 38 women (68%) and 18 men (32%). Results. It was seen that 47 patients had low ion levels (< 7µg/L) and nine had high ion levels (≥ 7µg/L). We found increased risks of high wear with decreasing CPR distance. Conclusion. The use of CPR distance measurements to predict hips at risk for elevated wear is needed for all patients with HRA. We recommend that patients with low CPR distances have at least one serum ion study performed while patients with CPR distance > 10 mm do not need routine ion studies. We believe that patients with low CPR distance and low ions do not need repeat ion studies unless the patient becomes symptomatic or has substantial radiographic changes. Cite this article: Bone Joint J 2017;99-B:865–71


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 1 | Pages 38 - 46
1 Jan 2010
Langton DJ Jameson SS Joyce TJ Hallab NJ Natu S Nargol AVF

Early failure associated with adverse reactions to metal debris is an emerging problem after hip resurfacing but the exact mechanism is unclear. We analysed our entire series of 660 metal-on-metal resurfacings (Articular Surface Replacement (ASR) and Birmingham Hip Resurfacing (BHR)) and large-bearing ASR total hip replacements, to establish associations with metal debris-related failures. Clinical and radiological outcomes, metal ion levels, explant studies and lymphocyte transformation tests were performed. A total of 17 patients (3.4%) were identified (all ASR bearings) with adverse reactions to metal debris, for which revision was required. This group had significantly smaller components, significantly higher acetabular component anteversion, and significantly higher whole concentrations of blood and joint chromium and cobalt ions than asymptomatic patients did (all p < 0.001). Post-revision lymphocyte transformation tests on this group showed no reactivity to chromium or cobalt ions. Explants from these revisions had greater surface wear than retrievals for uncomplicated fractures. The absence of adverse reactions to metal debris in patients with well-positioned implants usually implies high component wear. Surgeons must consider implant design, expected component size and acetabular component positioning in order to reduce early failures when performing large-bearing metal-on-metal hip resurfacing and replacement


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 10 | Pages 1293 - 1298
1 Oct 2007
Steffen R O’Rourke K Gill HS Murray DW

In 12 patients, we measured the oxygen concentration in the femoral head-neck junction during hip resurfacing through the anterolateral approach. This was compared with previous measurements made for the posterior approach. For the anterolateral approach, the oxygen concentration was found to be highly dependent upon the position of the leg, which was adjusted during surgery to provide exposure to the acetabulum and femoral head. Gross external rotation of the hip gave a significant decrease in oxygenation of the femoral head. Straightening the limb led to recovery in oxygen concentration, indicating that the blood supply was maintained. The oxygen concentration at the end of the procedure was not significantly different from that at the start. The anterolateral approach appears to produce less disruption to the blood flow in the femoral head-neck junction than the posterior approach for patients undergoing hip resurfacing. This may be reflected subsequently in a lower incidence of fracture of the femoral neck and avascular necrosis


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 8 | Pages 1100 - 1102
1 Aug 2009
Kutty S Pettit P Powell JN

Fracture of the neck of the femur after resurfacing arthroplasty usually leads to failure and conversion to a total hip replacement. We describe an intracapsular fracture of the femoral neck sustained after hip resurfacing which was treated by cannulated screws, resulting in union and retention of the resurfacing implant. The result at follow-up three years later was very satisfactory with a Harris hip score of 99


The Bone & Joint Journal
Vol. 99-B, Issue 4_Supple_B | Pages 33 - 40
1 Apr 2017
Galea VP Laaksonen I Matuszak SJ Connelly JW Muratoglu O Malchau H

Aims. Our first aim was to determine whether there are significant changes in the level of metal ions in the blood at mid-term follow-up, in patients with an Articular Surface Replacement (ASR) arthroplasty. Secondly, we sought to identify risk factors for any increases. Patients and Methods. The study involved 435 patients who underwent unilateral, metal-on-metal (MoM) hip resurfacing (HRA) or total hip arthroplasty (THA). These patients all had one measurement of the level of metal ions in the blood before seven years had passed post-operatively (early evaluation) and one after seven years had passed post-operatively (mid-term evaluation). Changes in ion levels were tested using a Wilcoxon signed-rank test. We identified subgroups at the highest risk of increase using a multivariable linear logistic regression model. Results. There were significant increases in the levels of metal ions for patients who underwent both MoM HRA (Chromium (Cr): 0.5 parts per billion (ppb); Cobalt (Co): 1.1 ppb) and MoM THA (Cr: 0.5 ppb; Co: 0.7 ppb). In a multivariable model considering MoM HRAs, the change in the levels of metal ions was influenced by female gender (Co: Odds Ratio (OR) 1.42; p = 0.002 and Cr: OR 1.08; p = 0.006). The change was found to be irrespective of the initial level for the MoM HRAs, whereas there was a negative relationship between the initial level and the change in the level for those with a MoM THA (Co: OR -0.43; p <  0.001 and Cr: OR -0.14; p = 0.033). Conclusion. The levels of metal ions in the blood increase significantly over the period until mid-term follow-up in patients with both a MoM HRA and those with a MoM THA. We recommend that the levels of metal ions be measured most frequently for women with a MoM HRA. While those with a MoM THA appear to stabilise at a certain level, the accuracy of this trend is not yet clear. Vigilant follow-up is still recommended. . Cite this article: Bone Joint J 2017;99-B(4 Supple B):33–40


Aims

To establish the survivorship, function, and metal ion levels in an unselected series of metal-on-metal hip resurfacing arthroplasties (HRAs) performed by a non-designer surgeon.

Methods

We reviewed 105 consecutive HRAs in 83 patients, performed by a single surgeon, at a mean follow-up of 14.9 years (9.3 to 19.1). The cohort included 45 male and 38 female patients, with a mean age of 49.5 years (SD 12.5)


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 2 | Pages 158 - 163
1 Feb 2011
Baker RP Pollard TCB Eastaugh-Waring SJ Bannister GC

We compared the medium-term clinical and radiological results of hybrid total hip replacement (THR) with metal-on-metal Birmingham hip resurfacing (BHR) in two groups of 54 young patients matched for age, gender, body mass index and pre-operative levels of activity. The clinical outcome was assessed by the University of California, Los Angeles (UCLA) activity score, the Oxford Hip Score (OHS) and the EuroQol scores. Radiologically, all hips were assessed for migration and osteolysis, the hybrid THRs for polyethylene wear and the BHRs for a pedestal sign. The mean follow-up of the patients with a hybrid THR was ten years and for those with a BHR, nine years. Four patients with a hybrid THR and one with a BHR had died. In each group five were lost to follow-up. The revision rate of the hybrid THRs was 16.7% (9 of 54) and of the BHRs 9.3% (5 of 54) (p = 0.195). Radiographs of a further eight hybrid THRs demonstrated wear and osteolysis, and they await revision (p = 0.008). Of the unrevised BHRs 90% had radiological changes, of which approximately 50% had progressed over the previous four years. All hybrid THRs demonstrated linear polyethylene wear with a mean of 1.24 mm (0.06 to 3.03). The BHRs recorded superior OHS (p = 0.013), UCLA (p = 0.008), and EuroQol visual analogue scores (p = 0.009). After nine years, patients with BHRs remained more active and had a lower rate of revision than those with hybrid THRs. Both groups demonstrated progressive radiological changes at medium-term follow-up


Bone & Joint 360
Vol. 9, Issue 1 | Pages 4 - 9
1 Feb 2020
Logishetty K Muirhead-Allwood SK Cobb JP


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 2 | Pages 172 - 176
1 Mar 2004
Glyn-Jones S Gill HS McLardy-Smith P Murray DW

The Birmingham hip resurfacing (BHR) arthroplasty is a metal-on-metal prosthesis for which no medium- or long-term results have been published. Despite this, it is increasing in popularity as an alternative to stemmed prostheses for younger patients. Since the fixation of the socket is conventional, the major concern is long-term failure of the femoral component. This can be predicted by the use of roentgen stereophotogrammetric analysis (RSA). We have therefore undertaken such a study of the BHR femoral component over a period of two years. Twenty patients (22 hips) underwent a standard BHR procedure. Migration of the femoral component was measured by RSA at intervals of three, six, 12 and 24 months. At 24 months the total three-dimensional migration of the head was 0.2 mm. This was not statistically significant. Previous studies have shown that implants which loosen quickly have rapid early migration. Our results therefore suggest that the BHR femoral component is an inherently stable device which is likely to perform well in the long term


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 2 | Pages 169 - 173
1 Feb 2007
Daniel J Ziaee H Pradhan C Pynsent PB McMinn DJW

This is a longitudinal study of the daily urinary output and the concentrations in whole blood of cobalt and chromium in patients with metal-on-metal resurfacings over a period of four years. Twelve-hour urine collections and whole blood specimens were collected before and periodically after a Birmingham hip resurfacing in 26 patients. All ion analyses were carried out using a high-resolution inductively-coupled plasma mass spectrometer. Clinical and radiological assessment, hip function scoring and activity level assessment revealed excellent hip function. There was a significant early increase in urinary metal output, reaching a peak at six months for cobalt and one year for chromium post-operatively. There was thereafter a steady decrease in the median urinary output of cobalt over the following three years, although the differences are not statistically significant. The mean whole blood levels of cobalt and chromium also showed a significant increase between the pre-operative and one-year post-operative periods. The blood levels then decreased to a lower level at four years, compared with the one-year levels. This late reduction was statistically significant for chromium but not for cobalt. The effects of systemic metal ion exposure in patients with metal-on-metal resurfacing arthroplasties continue to be a matter of concern. The levels in this study provide a baseline against which the in vivo wear performance of newer bearings can be compared


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 20 - 20
1 Sep 2012
Davda K Masjedi M Hart A Cobb J
Full Access

Metal on Metal hip resurfacing (MoM HR) can be an effective operation for the young arthritic hip population. However, errors in cup orientation have been associated with increased wear, circulating blood metal ions, and soft tissue abnormalities that can lead to premature failure of the bearing surface and subsequent revision surgery. While image free computer guidance has been shown to increase surgical accuracy in total hip arthroplasty, the role of image based technology in MoM HR is unclear. In this study, we compared the accuracy of cup orientation in MoM HR performed by either freehand technique or CT based navigation. Seventy five patients (81 hips) underwent either freehand (n=42) or navigation (n=39) surgery, both requiring a three dimensional (3D) CT surgical plan. Surgery was conducted by hip specialists blind to the method of cup implantation until the operation. Deviation in inclination and version from the planned orientation, as well as, number of cups within a 10° safe zone and 5° optimal zone of the target position was calculated using post operative 3D CT analysis. Error in inclination was significantly reduced with navigation compared to freehand technique (4° vs 6°, p=0.02). We could not detect a difference between the two groups for version error (5° vs 7°, p=0.06). There was a significantly greater number of hips within a 10° (87% vs 67%, p=0.04) and 5° (50% vs 20%, p=0.06) safe zone when navigated. Image based navigation can substantially improve accuracy in cup orientation. The results of our freehand group appear better than historic controls, suggesting the use of a 3D plan may help to reduce technical error and improve the learning curve in this technically demanding procedure. We advocate the use of image based navigation in MoM hip resurfacing arthroplasty


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 9 | Pages 1137 - 1142
1 Sep 2008
Heilpern GNA Shah NN Fordyce MJF

We report the outcome at a minimum of five years of 110 consecutive metal-on-metal Birmingham Hip Resurfacing arthroplasties in 98 patients. The procedures were performed between October 1999 and June 2002 by one surgeon. All patients were followed up clinically and radiologically. The mean follow-up was 71 months (60 to 93). Revision of either component was defined as failure.

The mean Harris Hip score at follow-up was 96.4 (53 to 100). The mean Oxford hip score was 41.9 (16 to 57) pre-operatively and 15.4 (12 to 49) post-operatively (p < 0.001). The mean University of California Los Angeles activity score was 3.91 (1 to 10) pre-operatively and 7.5 (4 to 10) post-operatively (p < 0.001).

There were four failures giving a survival at five years of 96.3% (95% confidence interval 92.8 to 99.8). When applying a new method to estimate narrowing of the femoral neck we identified a 10% thinning of the femoral neck in 16 hips (14.5%), but the relevance of this finding to the long-term outcome remains unclear.

These good medium-term results from an independent centre confirm the original data from Birmingham.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 29 - 29
1 Jan 2013
Sidaginamale R Langton D Lord J Joyce T Nargol A
Full Access

Background. We have previously described the relationship between wear rates of MOM components and soft tissue necrosis. In this study we investigated the link between wear rates, metal ion concentrations and osteolysis. Methods. All unilateral patients who underwent revision of hip resurfacings at our centre were included. Retrieved components were analysed using a coordinate measuring machine to determine total volumetric material loss and rates of wear. Given the accuracy of the wear calculations (which we have previously published), wear rates were considered “abnormal” if ≥3mm. 3. /yr. ROC curves were constructed to determine a Co concentration which would be clinically useful to detect abnormal wear. During revision, the presence/absence of osteolysis was documented. Results. There were 65 patients in total (mean time to revision was 41 months (2 to 98). 60 patients had suffered ARMD. 2 hips were revised for infection, 1 for osteolysis and 1 due to a loose cup and 1 for unexplained pain. A blood cobalt concentration >5µg/l was found to be 100%(62.2–100) specific and 94.4%(84.2–98.6) sensitive for the detection of abnormal wear. All patients with wear rates greater than 12mm. 3. /yr (n=21) were found to have osteolysis (the minimum total loss of material in this group of patients was 16mm3). ROC analysis showed that a blood cobalt ≥44.6µg/l was 97.2% specific for the detection of this rate of wear. 3 of the 21 patients with these rates of wear were asymptomatic. They decided on revision after discussion with the surgeon. Two were revised following acute femoral collapse but were completely pain free prior to these events. Conclusion. These data suggest that a blood cobalt concentration of 5µg/l can reliably identify an abnormally wearing resurfacing prosthesis. Elevated metal ion concentrations are associated with osteolysis, even in the absence of symptoms


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 11 | Pages 1522 - 1527
1 Nov 2008
Davis ET Olsen M Zdero R Waddell JP Schemitsch EH

A total of 20 pairs of fresh-frozen cadaver femurs were assigned to four alignment groups consisting of relative varus (10° and 20°) and relative valgus (10° and 20°), 75 composite femurs of two neck geometries were also used. In both the cadaver and the composite femurs, placing the component in 20° of valgus resulted in a significant increase in load to failure. Placing the component in 10° of valgus had no appreciable effect on increasing the load to failure except in the composite femurs with varus native femoral necks. Specimens in 10° of varus were significantly weaker than the neutrally-aligned specimens.

The results suggest that retention of the intact proximal femoral strength occurs at an implant angulation of ≥ 142°. However, the benefit of extreme valgus alignment may be outweighed in clinical practice by the risk of superior femoral neck notching, which was avoided in this study.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 28 - 28
1 Sep 2012
Sandiford N Muirhead-Allwood S Skinner J
Full Access

Introduction. Metal on metal hip resurfacing arthroplasty (MoM HR) has the highest revision rates according to the UK National Joint Registry. Revisions for lesions associated with soft tissue necrosis (pseudotumors) have been associated with poor outcomes. There is a relative paucity of information on early revision of painful HR prostheses. We present the results of a series of patients who underwent early revision of painful MoM HR procedures. Methods. This prospective study involved a consecutive series of patients undergoing revision of HR to THA. The diagnoses leading to revision are discussed. Clinical and radiological assessments were performed pre operatively as well as 6 weeks, 12 months postoperatively and yearly thereafter. Pre and post operative Harris Hip Score, Oxford Hip Score and WOMAC scores were calculated. Patient satisfaction was assessed using a visual analogue scale. Results. Revisions were performed for recurrent pain and effusion, infection and proximal femoral fractures. Both components were revised in 20 cases. There were 12 male and 13 female patients with average time to revision of 34.4 and 26.4 months respectively. The mean follow up period was 12.7 months (3 to 31). All patients reported relief of pain and excellent satisfaction scores (9/10 compared to 2/10 pre-operatively). Two patients experienced stiffness up to three months post operatively. Pre operative Oxford, Harris and WOMAC hip scores were 39.1, 36.4 and 52.2 respectively. Mean post operative scores at last follow up were 17.4, 89.8 and 6.1 respectively (p< 0.0001 for each score). All patients except those with femoral neck fractures had at least a small effusion. Conclusion. These results show that conversion of painful hip resurfacing prostheses to total hip arthroplasty is associated with improved function, pain relief and high levels of patient satisfaction


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 12 | Pages 1550 - 1554
1 Dec 2009
Lingard EA Muthumayandi K Holland JP

This study compared the demographic, clinical and patient-reported outcomes after total hip replacement (THR) and Birmingham Hip Resurfacing (BHR) carried out by a single surgeon. Patients completed a questionnaire that included the WOMAC, SF-36 scores and comorbid medical conditions. Data were collected before operation and one year after. The outcome scores were adjusted for age, gender, comorbid conditions and, at one year, for the pre-operative scores. There were 214 patients with a THR and 132 with a BHR. Patients with a BHR were significantly younger (49 vs 67 years, p < 0.0001), more likely to be male (68% vs 42% of THR, p < 0.0001) and had fewer comorbid conditions (1.3 vs 2.0, p < 0.0001). Before operation there was no difference in WOMAC and SF-36 scores, except for function, in which patients awaiting THR were worse than those awaiting a BHR.

At one year patients with a BHR reported significantly better WOMAC pain scores (p = 0.04) and in all SF-36 domains (p < 0.05). Patients undergoing BHR report a significantly greater improvement in general health compared with those with a THR.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 8 | Pages 1123 - 1123
1 Aug 2009
Krikler C


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 2 | Pages 164 - 171
1 Feb 2011
Langton DJ Joyce TJ Jameson SS Lord J Van Orsouw M Holland JP Nargol AVF De Smet KA

We sought to establish the incidence of joint failure secondary to adverse reaction to metal debris (ARMD) following metal-on-metal hip resurfacing in a large, three surgeon, multicentre study involving 4226 hips with a follow-up of 10 to 142 months. Three implants were studied: the Articular Surface Replacement; the Birmingham Hip Resurfacing; and the Conserve Plus. Retrieved implants underwent analysis using a co-ordinate measuring machine to determine volumetric wear. There were 58 failures associated with ARMD. The median chromium and cobalt concentrations in the failed group were significantly higher than in the control group (p < 0.001). Survival analysis showed a failure rate in the patients with Articular Surface Replacement of 9.8% at five years, compared with < 1% at five years for the Conserve Plus and 1.5% at ten years for the Birmingham Hip Resurfacing. Two ARMD patients had relatively low wear of the retrieved components. Increased wear from the metal-on-metal bearing surface was associated with an increased rate of failure secondary to ARMD. However, the extent of tissue destruction at revision surgery did not appear to be dose-related to the volumetric wear.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 1 | Pages 124 - 130
1 Jan 2009
Deuel CR Jamali AA Stover SM Hazelwood SJ

Bone surface strains were measured in cadaver femora during loading prior to and after resurfacing of the hip and total hip replacement using an uncemented, tapered femoral component. In vitro loading simulated the single-leg stance phase during walking. Strains were measured on the medial and the lateral sides of the proximal aspect and the mid-diaphysis of the femur. Bone surface strains following femoral resurfacing were similar to those in the native femur, except for proximal shear strains, which were significantly less than those in the native femur. Proximomedial strains following total hip replacement were significantly less than those in the native and the resurfaced femur.

These results are consistent with previous clinical evidence of bone loss after total hip replacement, and provide support for claims of bone preservation after resurfacing arthroplasty of the hip.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 10 | Pages 1445 - 1445
1 Oct 2005
IRVINE GB


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 4 | Pages 463 - 464
1 Apr 2005
Shimmin AJ Back D

Between April 1999 and April 2004, 3497 Birmingham hips were inserted by 89 surgeons. Fracture of the neck of the femur occurred in 50 patients, an incidence of 1.46%. Complete data were available for 45 patients in whom the incidence was 1.91% for women and 0.98% for men. The relative risk of fracture for women vs men was 1.94961 and this was statistically significant (p < 0.01).

The mean time to fracture was 15.4 weeks. In women the fractures occurred at a mean of 18.5 weeks and were more likely to have been preceded by a pro-dromal phase of pain and limping. In men the mean time to fracture was 13.5 weeks.

Significant varus placement of the femoral component, intra-operative notching of the femoral neck and technical problems were common factors in 85% of cases.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 1 | Pages 16 - 20
1 Jan 2007
Gill HS Campbell PA Murray DW De Smet KA

Resurfacing arthroplasty of the hip is being used increasingly as an alternative to total hip replacement, especially for young active patients. There is concern about necrosis of the femoral head after resurfacing which can result in fracture and loosening. Most systems use a cemented femoral component, with the potential for thermal necrosis of the cancellous bone of the reamed femoral head. We used thermal probes to record temperatures close to the cement-bone interface during resurfacing arthroplasty.

The maximum temperature recorded at the cement-bone interface in four cases was approximately 68°C which was higher than that reported to kill osteocytes. A modified surgical technique using insertion of a suction cannula into the lesser trochanter, generous pulsed lavage and early reduction of the joint significantly reduced the maximum recorded cancellous bone temperature to approximately 36°C in five cases (p = 0.014).

We recommend the modified technique since it significantly reduces temperatures at the cement-bone interface.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 12 | Pages 1566 - 1574
1 Dec 2009
Glyn-Jones S Pandit H Kwon Y Doll H Gill HS Murray DW

Metal-on-metal hip resurfacing is commonly performed for osteoarthritis in young active patients. We have observed cystic or solid masses, which we have called inflammatory pseudotumours, arising around these devices. They may cause soft-tissue destruction with severe symptoms and a poor outcome after revision surgery. The aim of this study was to determine the incidence of and risk factors for pseudotumours that are serious enough to require revision surgery.

Since 1999, 1419 metal-on-metal hip resurfacings have been implanted by our group in 1224 patients; 1.8% of the patients had a revision for pseudotumour. In this series the Kaplan-Meier cumulative revision rate for pseudotumour increased progressively with time. At eight years, in all patients, it was 4% (95% confidence interval (CI) 2.2 to 5.8). Factors significantly associated with an increase in revision rate were female gender (p < 0.001), age under 40 (p = 0.003), small components (p = 0.003), and dysplasia (p = 0.019), whereas implant type was not (p = 0.156). These factors were inter-related, however, and on fitting a Cox proportional hazard model only gender (p = 0.002) and age (p = 0.024) had a significant independent influence on revision rate; size nearly reached significance (p = 0.08). Subdividing the cohort according to significant factors, we found that the revision rate for pseudotumours in men was 0.5% (95% CI 0 to 1.1) at eight years wheras in women over 40 years old it was 6% (95% CI 2.3 to 10.1) at eight years and in women under 40 years it was 13.1% at six years (95% CI 0 to 27) (p < 0.001).

We recommend that resurfacings are undertaken with caution in women, particularly those under 40 years of age but they remain a good option in young men. Further work is required to understand the aetiology of pseudotumours so that this complication can be avoided.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 4 | Pages 555 - 557
1 Apr 2011
Marchese M Sinisi M Anand P Di Mascio L Humphrey J

A 60-year-old man developed severe neuropathic pain and foot-drop in his left leg following resurfacing arthroplasty of the left hip. The pain was refractory to all analgesics for 16 months. At exploration, a PDS suture was found passing through the sciatic nerve at several points over 6 cm and terminating in a large knot. After release of the suture and neurolysis there was dramatic and rapid improvement of the neuropathic pain and of motor function.

This case represents the human equivalent of previously described nerve ligation in an animal model of neuropathic pain. It emphasises that when neuropathic pain is present after an operation, the nerve related to the symptoms must be inspected, and that removal of a suture or irritant may lead to relief of pain, even after many months.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 8 | Pages 1019 - 1024
1 Aug 2009
Grammatopolous G Pandit H Kwon Y Gundle R McLardy-Smith P Beard DJ Murray DW Gill HS

Inflammatory pseudotumours occasionally occur after metal-on-metal hip resurfacing and often lead to revision. Our aim was to determine the severity of this complication by assessing the outcome of revision in these circumstances and by comparing this with the outcome of other metal-on-metal hip resurfacing revisions as well as that of matched primary total hip replacements.

We identified 53 hips which had undergone metal-on-metal hip resurfacing and required revision at a mean of 1.59 years (0.01 to 6.69) after operation. Of these, 16 were revised for pseudotumours, 21 for fracture and 16 for other reasons. These were matched by age, gender and diagnosis with 103 patients undergoing primary total hip replacement with the Exeter implant.

At a mean follow-up of three years (0.8 to 7.2) the outcome of metal-on-metal hip resurfacing revision for pseudotumour was poor with a mean Oxford hip score of 20.9 (sd 9.3) and was significantly worse (p < 0.001) than the outcome for fracture with a mean Oxford hip score of 40.2 (sd 9.2) or that for other causes with a mean Oxford hip score of 37.8 (sd 9.4). The clinical outcome of revision for pseudotumour was also significantly worse (p < 0.001) than the outcome of matched primary total hip replacements. By contrast, the outcome for fracture and other causes was not significantly different from that of matched primary total hip replacements (p = 0.065). After revision for pseudotumour there were three cases of recurrent dislocation, three of palsy of the femoral nerve, one of stenosis of the femoral artery and two of loosening of the component. Five hips required further revision. In three of these there was evidence of recurrent pseudotumour, and one is currently awaiting further revision. The incidence of major complications after revision for pseudotumour (50%) was significantly higher (p = 0.018) than that after revision for other causes (14%).

The outcome of revision for pseudotumour is poor and consideration should be given to early revision to limit the extent of the soft-tissue destruction. The outcome of resurfacing revision for other causes is good.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 4 | Pages 449 - 454
1 Apr 2006
Hart AJ Hester T Sinclair K Powell JJ Goodship AE Pele L Fersht NL Skinner J

We have studied the relationship between metal ion levels and lymphocyte counts in patients with metal-on-metal hip resurfacings. Peripheral blood samples were analysed for lymphocyte subtypes and whole blood cobalt and chromium ion levels in 68 patients (34 with metal-on-metal hip resurfacings and 34 with standard metal-on-polyethylene total hip replacements). All hip components were radiologically well-fixed and the patients were asymptomatic. Cobalt and chromium levels were significantly elevated in the patients with metal-on-metal hip resurfacings, compared with the patients with standard metal-on-polyethylene designs (p < 0.0001). There was a statistically significant decrease in the level of CD8+ cells (T-cytotoxic/suppressor) (p = 0.005) in the metal-on-metal hip resurfacing group. A threshold level of blood cobalt and chromium ions was associated with reduced CD8+ T-cell counts. We have no evidence that our patients suffered as a result of this reduced level of CD8+ T-cells.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 7 | Pages 989 - 989
1 Jul 2007
VENDITTOLI P GANAPATHI M LAVIGNE M


Bone & Joint Open
Vol. 4, Issue 3 | Pages 182 - 187
14 Mar 2023
Sheridan GA Hanlon M Welch-Phillips A Spratt K Hagan R O'Byrne JM Kenny PJ Kurmis AP Masri BA Garbuz DS Hurson CJ

Aims. Hip resurfacing remains a potentially valuable surgical procedure for appropriately-selected patients with optimised implant choices. However, concern regarding high early failure rates continues to undermine confidence in use. A large contributor to failure is adverse local tissue reactions around metal-on-metal (MoM) bearing surfaces. Such phenomena have been well-explored around MoM total hip arthroplasties, but comparable data in equivalent hip resurfacing procedures is lacking. In order to define genetic predisposition, we performed a case-control study investigating the role of human leucocyte antigen (HLA) genotype in the development of pseudotumours around MoM hip resurfacings. Methods. A matched case-control study was performed using the prospectively-collected database at the host institution. In all, 16 MoM hip resurfacing 'cases' were identified as having symptomatic periprosthetic pseudotumours on preoperative metal artefact reduction sequence (MARS) MRI, and were subsequently histologically confirmed as high-grade aseptic lymphocyte-dominated vasculitis-associated lesions (ALVALs) at revision surgery. ‘Controls’ were matched by implant type in the absence of evidence of pseudotumour. Blood samples from all cases and controls were collected prospectively for high resolution genetic a nalysis targeting 11 separate HLA loci. Statistical significance was set at 0.10 a priori to determine the association between HLA genotype and pseudotumour formation, given the small sample size. Results. Using a previously-reported ALVAL classification, the majority of pseudotumour-positive caseswere found to have intermediate-grade group 2 (n = 10; 63%) or group 3 (n = 4; 25%) histological findings. Two further patients (13%) had high-grade group 4 lesions. HLA-DQB1*05:03:01 (p = 0.0676) and HLA-DRB1*14:54:01 (p = 0.0676) alleles were significantly associated with a higher risk of pseudotumour formation, while HLA-DQA1*03:01:01 (p = 0.0240), HLA-DRB1*04:04:01 (p = 0.0453), HLA-C*01:02:01 (p = 0.0453), and HLA-B*27:05:02 (p = 0.0855) were noted to confer risk reduction. Conclusion. These findings confirm the association between specific HLA genotypes and the risk of pseudotumour development around MoM hip resurfacings. Specifically, the two ‘at risk’ alleles (DQB1*05:03:01 and DRB1*14:54:01) may hold clinical value in preoperative screening and prospective surgical decision-making. Cite this article: Bone Jt Open 2023;4(3):182–187


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 38 - 38
1 Dec 2022
Sheridan G Hanlon M Welch-Phillips A Spratt K Hagan R O'Byrne J Kenny P Kurmis A Masri B Garbuz D Hurson C
Full Access

Hip resurfacing may be a useful surgical procedure when patient selection is correct and only implants with superior performance are used. In order to establish a body of evidence in relation to hip resurfacing, pseudotumour formation and its genetic predisposition, we performed a case-control study investigating the role of HLA genotype in the development of pseudotumour around MoM hip resurfacings. All metal-on-metal (MoM) hip resurfacings performed in the history of the institution were assessed. A total of 392 hip resurfacings were performed by 12 surgeons between February 1st 2005 and October 31st 2007. In all cases, pseudotumour was confirmed in the preoperative setting on Metal Artefact Reduction Sequencing (MARS) MRI. Controls were matched by implant (ASR or BHR) and absence of pseudotumour was confirmed on MRI. Blood samples from all cases and controls underwent genetic analysis using Next Generation Sequencing (NGS) assessing for the following alleles of 11 HLA loci (A, B, C, DRB1, DRB3/4/5, DQA1, DQB1, DPB1, DPA1). Statistical significance was determined using a Fisher's exact test or Chi-Squared test given the small sample size to quantify the clinical association between HLA genotype and the need for revision surgery due to pseudotumour. Both groups were matched for implant type (55% ASR, 45% BHR in both the case and control groups). According to the ALVAL histological classification described by Kurmis et al., the majority of cases (63%, n=10) were found to have group 2 histological findings. Four cases (25%) had group 3 histological findings and 2 (12%) patients had group 4 findings. Of the 11 HLA loci analysed, 2 were significantly associated with a higher risk of pseudotumour formation (DQB1*05:03:01 and DRB1*14:54:01) and 4 were noted to be protective against pseudotumour formation (DQA1*03:01:01, DRB1*04:04:01, C*01:02:01, B*27:05:02). These findings further develop the knowledge base around specific HLA genotypes and their role in the development of pseudotumour formation in MoM hip resurfacing. Specifically, the two alleles at higher risk of pseudotumour formation (DQB1*05:03:01 and DRB1*14:54:01) in MoM hip resurfacing should be noted, particularly as patient-specific genotype-dependent surgical treatments continue to develop in the future


The Bone & Joint Journal
Vol. 106-B, Issue 6 | Pages 540 - 547
1 Jun 2024
Nandra RS Elnahal WA Mayne A Brash L McBryde CW Treacy RBC

Aims. The Birmingham Hip Resurfacing (BHR) was introduced in 1997 to address the needs of young active patients using a historically proven large-diameter metal-on-metal (MoM) bearing. A single designer surgeon’s consecutive series of 130 patients (144 hips) was previously reported at five and ten years, reporting three and ten failures, respectively. The aim of this study was to extend the follow-up of this original cohort at 25 years. Methods. The study extends the reporting on the first consecutive 144 resurfacing procedures in 130 patients for all indications. All operations were undertaken between August 1997 and May 1998. The mean age at operation was 52.1 years (SD 9.93; 17 to 76), and included 37 female patients (28.5%). Failure was defined as revision of either component for any reason. Kaplan-Meier survival analysis was performed. Routine follow-up with serum metal ion levels, radiographs, and Oxford Hip Scores (OHSs) was undertaken. Results. Overall implant survival was 83.50% (95% confidence interval (CI) 0.79 to 0.90) at 25 years, and the number at risk was 79. Survival in male patients at 25 years was 89.5% (95% CI 0.83 to 0.96) compared to 66.9% for female patients (95% CI 0.51 to 0.83). Ten additional failures occurred in the period of ten to 25 years. These involved an adverse reaction to metal debris in four patients, a periprosthetic femoral neck fracture affecting five patients, and aseptic loosening in one patient. The median chromium levels were 49.50 nmol/l (interquartile range (IQR) 34 to 70), and the median cobalt serum levels were 42 nmol/l (IQR 24.50 to 71.25). The median OHS at last follow-up was 35 (IQR 10 to 48). During the 25-year study period, 29 patients died. Patient survival at 25 years was 75.10% (95% CI 0.67 to 0.83). Conclusion. This study demonstrates that MoM hip resurfacing using the BHR provides a durable alternative to total hip arthroplasty (THA), particularly in younger male patients with osteoarthritis wishing to maintain a high level of function. These results compare favourably to the best results for THAs. Cite this article: Bone Joint J 2024;106-B(6):540–547


The Bone & Joint Journal
Vol. 101-B, Issue 4 | Pages 426 - 434
1 Apr 2019
Logishetty K van Arkel RJ Ng KCG Muirhead-Allwood SK Cobb JP Jeffers JRT

Aims. The hip’s capsular ligaments passively restrain extreme range of movement (ROM) by wrapping around the native femoral head/neck. We determined the effect of hip resurfacing arthroplasty (HRA), dual-mobility total hip arthroplasty (DM-THA), conventional THA, and surgical approach on ligament function. Materials and Methods. Eight paired cadaveric hip joints were skeletonized but retained the hip capsule. Capsular ROM restraint during controlled internal rotation (IR) and external rotation (ER) was measured before and after HRA, DM-THA, and conventional THA, with a posterior (right hips) and anterior capsulotomy (left hips). Results. Hip resurfacing provided a near-native ROM with between 5° to 17° increase in IR/ER ROM compared with the native hip for the different positions tested, which was a 9% to 33% increase. DM-THA generated a 9° to 61° (18% to 121%) increase in ROM. Conventional THA generated a 52° to 100° (94% to 199%) increase in ROM. Thus, for conventional THA, the capsule function that exerts a limit on ROM is lost. It is restored to some extent by DM-THA, and almost fully restored by hip resurfacing. In positions of low flexion/extension, the posterior capsulotomy provided more normal function than the anterior, possibly because the capsule was shortened during posterior repair. However, in deep flexion positions, the anterior capsulotomy functioned better. Conclusion. Native head-size and capsular repair preserves capsular function after arthroplasty. The anterior and posterior approach differentially affect postoperative biomechanical function of the capsular ligaments. Cite this article: Bone Joint J 2019;101-B:426–434


Bone & Joint Research
Vol. 11, Issue 5 | Pages 317 - 326
23 May 2022
Edwards TC Guest B Garner A Logishetty K Liddle AD Cobb JP

Aims. This study investigates the use of the metabolic equivalent of task (MET) score in a young hip arthroplasty population, and its ability to capture additional benefit beyond the ceiling effect of conventional patient-reported outcome measures. Methods. From our electronic database of 751 hip arthroplasty procedures, 221 patients were included. Patients were excluded if they had revision surgery, an alternative hip procedure, or incomplete data either preoperatively or at one-year follow-up. Included patients had a mean age of 59.4 years (SD 11.3) and 54.3% were male, incorporating 117 primary total hip and 104 hip resurfacing arthroplasty operations. Oxford Hip Score (OHS), EuroQol five-dimension questionnaire (EQ-5D), and the MET were recorded preoperatively and at one-year follow-up. The distribution was examined reporting the presence of ceiling and floor effects. Validity was assessed correlating the MET with the other scores using Spearman’s rank correlation coefficient and determining responsiveness. A subgroup of 93 patients scoring 48/48 on the OHS were analyzed by age, sex, BMI, and preoperative MET using the other metrics to determine if differences could be established despite scoring identically on the OHS. Results. Postoperatively the OHS and EQ-5D demonstrate considerable negatively skewed distributions with ceiling effects of 41.6% and 53.8%, respectively. The MET was normally distributed postoperatively with no relevant ceiling effect. Weak-to-moderate significant correlations were found between the MET and the other two metrics. In the 48/48 subgroup, no differences were found comparing groups with the EQ-5D, however significantly higher mean MET scores were demonstrated for patients aged < 60 years (12.7 (SD 4.7) vs 10.6 (SD 2.4), p = 0.008), male patients (12.5 (SD 4.5) vs 10.8 (SD 2.8), p = 0.024), and those with preoperative MET scores > 6 (12.6 (SD 4.2) vs 11.0 (SD 3.3), p = 0.040). Conclusion. The MET is normally distributed in patients following hip arthroplasty, recording levels of activity which are undetectable using the OHS. Cite this article: Bone Joint Res 2022;11(5):317–326


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 110 - 110
1 Feb 2020
Samuel L Warren J Rabin J Acuna A Shuster A Patterson J Mont M Brooks P
Full Access

Background. Proper positioning of the acetabular component is critical for prevention of dislocation and excessive wear for total hip arthroplasty (THA) and hip resurfacing. Consideration of preoperative pelvic tilt (PT) may aid in acetabular component placement. The purpose of this study was to investigate how PT changes after hip resurfacing, via pre and post-operative radiographic analysis of anterior pelvic plane (APP), and whether radiographic analysis of the APP is a reproducible method for evaluating PT in resurfaced hips. Methods. A consecutive group of 228 patients from a single surgeon who had hip resurfacing were evaluated. We obtained x-rays from an institutional database for these patients who had their surgeries between January 1. st. , 2014 to December 31. st. , 2016. Pelvic tilt (PT) was measured by two observers before and after resurfacing utilizing a standardized radiographic technique. Correlation coefficients were calculated for PT measurements between observers, and pre- and post-surgery. Results. Mean preoperative PT was 0.7° (SD ± 6.6°) and 0.4° (SD ± 6.1°). Mean post-operative PT was −1.2° (SD ± 6.2°) and −1.2° (SD ± 6.0°). Correlations between pre and post-operative PT were R=.829 (p<.001) and R = .837 (p<.001). 80.6% to 82.5% of patients had variation <5°, 15.8% to 17.8% had variation between 5–10°, and 1.6 to1.8% had a variation >10°. Intraclass correlation coefficients between observers were R = .987 (95% CI, .963–.981; p<.001) preoperatively, and R=.985 (95 CI, .963–.981; p<.001) postoperatively. (See Fig 1). Conclusion. After hip resurfacing arthroplasty, the mean difference between preoperative and postoperative PT was less than 1°. These results suggest that near-native PT is maintained with consistency after hip resurfacing, a finding that is variable following THA. Since variations in PT affect functional acetabular position, these results support the use of pelvic tilt measurement in pre-operative planning for hip arthroplasty with a high degree of inter-observer reliability. For any figures or tables, please contact the authors directly


The Bone & Joint Journal
Vol. 103-B, Issue 7 Supple B | Pages 84 - 90
1 Jul 2021
Yang J Olsen AS Serino J Terhune EB DeBenedetti A Della Valle CJ

Aims. The proportion of arthroplasties performed in the ambulatory setting has increased considerably. However, there are concerns whether same-day discharge may increase the risk of complications. The aim of this study was to compare 90-day outcomes between inpatient arthroplasties and outpatient arthroplasties performed at an ambulatory surgery centre (ASC), and determine whether there is a learning curve associated with performing athroplasties in an ASC. Methods. Among a single-surgeon cohort of 970 patients who underwent arthroplasty at an ASC, 854 (88.0%) were matched one-to-one with inpatients based on age, sex, American Society of Anesthesiologists (ASA) grade, BMI, and procedure (105 could not be adequately matched and 11 lacked 90-day follow-up). The cohort included 281 total hip arthroplasties (THAs) (32.9%), 267 unicompartmental knee arthroplasties (31.3%), 242 primary total knee arthroplasties (TKAs) (28.3%), 60 hip resurfacings (7.0%), two revision THAs (0.3%), and two revision TKAs (0.3%). Outcomes included readmissions, reoperations, visits to the emergency department, unplanned clinic visits, and complications. Results. The inpatient and outpatient groups were similar in all demographic variables, reflecting successful matching. The reoperation rate was 0.9% in both cohorts (p = 1.000). Rates of readmission (2.0% inpatient vs 1.6% outpatient), any complications (5.9% vs 5.6%), minor complications (4.2% vs 3.9%), visits to the emergency department (2.7% vs 1.4%), and unplanned clinic visits (5.7% vs 5.5%) were lower in the outpatient group but did not reach significance with the sample size studied. A learning curve may exist, as seen by significant reductions in the reoperation and overall complication rates among outpatient arthroplasties over time (p = 0.032 and p = 0.007, respectively), despite those in this group becoming significantly older and heavier (both p < 0.001) during the study period. Conclusion. Arthroplasties performed at ASCs appear to be safe in appropriately selected patients, but may be associated with a learning curve as shown by the significant decrease in complication and reoperation rates during the study period. Cite this article: Bone Joint J 2021;103-B(7 Supple B):84–90


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 39 - 39
23 Jun 2023
LaValva SM Lebrun DG Canoles HG Ren R Padgett DE Su EP
Full Access

Competitive dancers represent a unique patient population in the setting of hip arthroplasty given the high degree of hip strength and mobility required by their profession. We sought to determine the clinical outcomes and ability to return to competitive dance after total hip arthroplasty (THA) or hip resurfacing arthroplasty (HRA) among competitive dancers. Active competitive dancers who underwent primary THA or HRA at a single institution with minimum one-year follow-up were included in the study. Primary outcomes included (1) the rate of return to competitive dance, (2) three PROMs (modified Harris Hip Score [mHHS], Hip Disability and Osteoarthritis Outcome Score for Joint Replacement [HOOS-JR], and Lower Extremity Activity Scale [LEAS]), and (3) post-operative complications. Forty-nine hips in 39 patients (mean age 56±13 years; 80% female) were included. Mean follow-up was 4.9±5.1 years. Thirty-seven THAs and 12 HRAs were performed. Ninety-six percent of patients returned to competitive dance activities post-operatively. With respect to PROMs, there were statistically significant improvements in mHHS, HOOS-JR, and LEAS from baseline to ≥ 1 year post-operatively. There were complications in 9/49 (18%) hips post-operatively, five (10%) of which required revision surgery. Active competitive dancers experienced significant improvements in functional outcome scores after THA or HRA, with a rate of return to competitive dance of 96%


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 11 - 11
23 Feb 2023
Hardwick-Morris M Twiggs J Miles B Walter WL
Full Access

Iliopsoas tendonitis occurs in up to 30% of patients after hip resurfacing arthroplasty (HRA) and is a common reason for revision. The primary purpose of this study was to validate our novel computational model for quantifying iliopsoas impingement in HRA patients using a case-controlled investigation. Secondary purpose was to compare these results with previously measured THA patients. We conducted a retrospective search in an experienced surgeon's database for HRA patients with iliopsoas tendonitis, confirmed via the active hip flexion test in supine, and control patients without iliopsoas tendonitis, resulting in two cohorts of 12 patients. The CT scans were segmented, landmarked, and used to simulate the iliopsoas impingement in supine and standing pelvic positions. Three discrete impingement values were output for each pelvic position, and the mean and maximum of these values were reported. Cup prominence was measured using a novel, nearest-neighbour algorithm. The mean cup prominence for the symptomatic cohort was 10.7mm and 5.1mm for the asymptomatic cohort (p << 0.01). The average standing mean impingement for the symptomatic cohort was 0.1mm and 0.0mm for the asymptomatic cohort (p << 0.01). The average standing maximum impingement for the symptomatic cohort was 0.2mm and 0.0mm for the asymptomatic cohort (p << 0.01). Impingement significantly predicted the probability of pain in logistic regression models and the simulation had a sensitivity of 92%, specificity of 91%, and an AUC ROC curve of 0.95. Using a case-controlled investigation, we demonstrated that our novel simulation could detect iliopsoas impingement and differentiate between the symptomatic and asymptomatic cohorts. Interestingly, the HRA patients demonstrated less impingement than the THA patients, despite greater cup prominence. In conclusion, this tool has the potential to be used preoperatively, to guide decisions about optimal cup placement, and postoperatively, to assist in the diagnosis of iliopsoas tendonitis


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 105 - 105
10 Feb 2023
Xu J Veltman W Chai Y Walter W
Full Access

Navigation in total hip arthroplasty has been shown to improve acetabular positioning and can decrease the incidence of mal-positioned acetabular components. The aim of this study was to assess two surgical guidance systems by comparing intra-operative measurements of acetabular component inclination and anteversion with a post-operative CT scan. We prospectively collected intra-operative navigation data from 102 hips receiving conventional THA or hip resurfacing arthroplasty through either a direct anterior or posterior approach. Two guidance systems were used simultaneously: an inertial navigation system (INS) and optical navigation system (ONS). Acetabular component anteversion and inclination was measured on a post-operative CT. The average age of the patients was 64 years (range: 24-92) and average BMI was 27 kg/m. 2. (range 19-38). 52% had hip surgery through an anterior approach. 98% of the INS measurements and 88% of the ONS measurements were within 10° of the CT measurements. The mean (and standard deviation) of the absolute difference between the post-operative CT and the intra-operative measurements for inclination and anteversion were 3.0° (2.8) and 4.5° (3.2) respectively for the ONS, along with 2.1° (2.3) and 2.4° (2.1) respectively for the INS. There was significantly lower mean absolute difference to CT for the INS when compared to ONS in both anteversion (p<0.001) and inclination (p=0.02). Both types of navigation produced reliable and reproducible acetabular cup positioning. It is important that patient-specific planning and navigation are used together to ensure that surgeons are targeting the optimal acetabular cup position. This assistance with cup positioning can provide benefits over free-hand techniques, especially in patients with an altered acetabular structure or extensive acetabular bone loss. In conclusion, both ONS and INS allowed for adequate acetabular positioning as measured on postoperative CT, and thus provide reliable intraoperative feedback for optimal acetabular component placement


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 106 - 106
10 Feb 2023
Lin D Xu J Weinrauch P Yates P Young D Walter W
Full Access

Hip resurfacing arthroplasty (HRA) is a bone conserving alternative to total hip arthroplasty. We present the early 1 and 2-year clinical and radiographical follow-up of a novel ceramic-on-ceramic (CoC) HRA in a multi-centric Australian cohort. Patient undergoing HRA between September 2018 and April 2021 were prospectively included. Patient-reported outcome measures (PROMS) in the form of the Forgotten Joint Score (FJS), HOOS Jr, WOMAC, Oxford Hip Score (OHS) and UCLA Activity Score were collected preoperatively and at 1- and 2-years post-operation. Serial radiographs were assessed for migration, component alignment, evidence of osteolysis/loosening and heterotopic ossification formation. 209 patients were identified of which 106 reached 2-year follow-up. Of these, 187 completed PROMS at 1 year and 90 at 2 years. There was significant improvement in HOOS (p< 0.001) and OHS (p< 0.001) between the pre-operative, 1-year and 2-years outcomes. Patients also reported improved pain (p<0.001), function (p<0.001) and reduced stiffness (p<0.001) as measured by the WOMAC score. Patients had improved activity scores on the UCLA Active Score (p<0.001) with 53% reporting return to impact activity at 2 years. FJS at 1 and 2-years were not significantly different (p=0.38). There was no migration, osteolysis or loosening of any of the implants. The mean acetabular cup inclination angle was 41.3° and the femoral component shaft angle was 137°. No fractures were reported over the 2-year follow-up with only 1 patient reporting a sciatic nerve palsy. There was early return to impact activities in more than half our patients at 2 years with no early clinical or radiological complications related to the implant. Longer term follow-up with increased patient numbers are required to restore surgeon confidence in HRA and expand the use of this novel product. In conclusion, CoC resurfacing at 2-years post-operation demonstrate promising results with satisfactory outcomes in all recorded PROMS


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_11 | Pages 35 - 35
7 Jun 2023
Warder H Sanders T Wright N Hall-Thompson B Alford S Johnson D
Full Access

Climbers and mountaineers will present to arthroplasty surgeons in need of hip replacement surgeries. There is a lack of guidance for both parties with a paucity in the literature. Climbing is often considered a high-risk activity to perform with a total hip replacement, due to the positions the hip is weighted in, and the potential austere environment in which an injury may occur. The aim was to assess levels of climbing and mountaineering possible following hip arthroplasty, and any factors affecting these levels. Ethical approval was obtained from the University of Central Lancashire. An anonymous online questionnaire was disseminated via email, social media and word-of-mouth to include all climbers, hill-walkers or mountaineers across the UK. This was used to collect climbing and mountaineering ability at various timepoints, along with scores such as the Oxford Hip Score and UCLA Score. The Kappa statistic was used to assess for correlations. Of the responders, 28 had undergone right hip arthroplasty surgery, with 11 having left hips and 22 receiving bilateral hips. A total of 67 of the replaced hips were total hip replacements, with 16 having undergone hip resurfacing. There is a fair agreement in level of climbing ability 3 months pre- and 3 months post-operatively (kappa=0.287, p<0.001), and a substantial agreement between 1 year post-operatively and currently for both climbing (kappa=0.730, p<0.001) and mountaineering (kappa=0.684, p<0.001). Impressively, 17 participants are climbing at more than E1 trad or 6c sport at one or more time points post operatively, which is regarded as an advanced level within the climbing community. Out of those 17 participants, 8 were climbing at this level within 3 months post-operatively. The level of climbing possible following hip arthroplasty surgery is above what is expected and perhaps desired by the operating surgeon. It is essential to take the individual patient into account when planning an operative intervention such as arthroplasty. The one year post-operative time point is highly predictive of longer term outcomes for both climbing and mountaineering


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 75 - 75
23 Jun 2023
Blom A
Full Access

There is paucity of reliable data examining the treatment pathway for hip replacements over the life of the patient in terms of risk of revision and re-revisions. We did a retrospective observational registry-based study of the National Joint Registry, using data on hip replacements from all participating hospitals in England and Wales, UK. We included data on all first revisions, with an identifiable primary procedure, with osteoarthritis as the sole indication for the original primary procedure. Kaplan-Meier estimates were used to determine the cumulative probability of revision and subsequent re-revision after primary hip replacement. Analyses were stratified by age and gender, and the influence of time from first to second revision on the risk of further revision was explored. Between 2003, and 2019, there were 29 010 revision hip replacements with a linked primary episode. Revision rates of revision hip replacements were higher in patients younger than 55 years than in older age groups. After revision of primary total hip replacement, 21·3% (95% CI 18·6–24·4) of first revisions were revised again within 15 years, 22·3% (20·3–24·4) of second revisions were revised again within 7 years, and 22·3% (18·3–27·0) of third revisions were revised again within 3 years. After revision of hip resurfacing, 23·7% (95% CI 19·6–28·5) of these revisions were revised again within 15 years, 21·0% (17·0–25·8) of second revisions were revised again within 7 years, and 19·3% (11·9–30·4) of third revisions were revised again within 3 years. A shorter time between revision episodes was associated with earlier subsequent revision. Younger patients are at an increased risk of multiple revisions. Patients who undergo a revision have a steadily increasing risk of further revision the more procedures they undergo, and each subsequent revision lasts for approximately half the time of the previous one


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_4 | Pages 123 - 123
1 Mar 2021
Jelsma J Schotanus M van Kuijk S Buil I Heyligers I Grimm B
Full Access

Hip resurfacing arthroplasty (HRA) became a popular procedure in the early 90s because of the improved wear characteristic, preserving nature of the procedure and the optimal stability and range of motion. Concerns raised since 2004 when metal ions were seen in blood and urine of patients with a MoM implant. Design of the prosthesis, acetabular component malpositioning, contact-patch-to-rim distance (CPR) and a reduced joint size all seem to play a role in elevated metal ion concentrations. Little is known about the influence of physical activity (PA) on metal ion concentrations. Implant wear is thought to be a function of use and thus of patient activity levels. Wear of polyethylene acetabular bearings was positively correlated with patient's activity in previous studies. It is hypothesized that daily habitual physical activity of patients with a unilateral resurfacing prosthesis, measured by an activity monitor, is associated with habitual physical activity. A prospective, explorative study was conducted. Only patients with a unilateral hip resurfacing prosthesis and a follow-up of 10 ± 1 years were included. Metal ion concentrations were determined using ICP-MS. Habitual physical activity of subjects was measured in daily living using an acceleration-based activity monitor. Outcome consisted of quantitative and qualitative activity parameters. In total, 16 patients were included. 12 males (75%) and 4 females (25%) with a median age at surgery of 55.5 ± 9.7 years [43.0 – 67.9] and median follow-up of 9.9 ± 1.0 years [9.1 – 10.9]. The median cobalt and chromium ion concentrations were 25 ± 13 and 38 ± 28 nmol/L. A significant relationship, when adjusting for age at surgery, BMI, cup size and cup inclination, between sit-stand transfers (p = .034) and high intensity peaks (p = .001) with cobalt ion concentrations were found (linear regression analysis). This study showed that a high number of sit-stand transfers and a high number of high intensity peaks is significantly correlated with high metal ion concentrations, but results should be interpreted with care. For patients it seems save to engage in activities with low intensity peaks like walking or cycling without triggering critical wear or metal ions being able to achieve important general health benefits and quality of life, although the quality (high intensity peaks) of physical activity and behaviour of patients (sit-stand-transfers) seem to influence metal ion concentrations


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 11 | Pages 1493 - 1497
1 Nov 2010
Simpson JM Villar RN

We review the history and literature of hip resurfacing arthroplasty. Resurfacing and the science behind it continues to evolve. Recent results, particularly from the national arthroplasty registers, have spread disquiet among both surgeons and patients. A hip resurfacing arthroplasty is not a total hip replacement, but should perhaps be seen as a means of delaying it. The time when hip resurfacing is offered to a patient may be different from that for a total hip replacement. The same logic can apply to the timing of revision surgery. Consequently, the comparison of resurfacing with total hip replacement may be a false one. Nevertheless, the need for innovative solutions for young arthroplasty patients is clear. Total hip replacement can be usefully delayed in many of these patients by the use of hip resurfacing arthroplasty


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 5 | Pages 592 - 600
1 May 2006
Pollard TCB Baker RP Eastaugh-Waring SJ Bannister GC

We compared the five- to seven-year clinical and radiological results of the metal-on-metal Birmingham hip resurfacing with a hybrid total hip arthroplasty in two groups of 54 hips, matched for gender, age, body mass index and activity level. Function was excellent in both groups, as measured by the Oxford hip score, but the Birmingham hip resurfacings had higher University of California at Los Angeles activity scores and better EuroQol quality of life scores. The total hip arthroplasties had a revision or intention-to-revise rate of 8%, and the Birmingham hip resurfacings of 6%. Both groups demonstrated impending failure on surrogate end-points. Of the total hip arthroplasties, 12% had polyethylene wear and osteolysis under observation, and 8% of Birmingham hip resurfacings showed migration of the femoral component. Polyethylene wear was present in 48% of the hybrid hips without osteolysis. Of the femoral components in the Birmingham hip resurfacing group which had not migrated, 66% had radiological changes of unknown significance


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_15 | Pages 109 - 109
1 Aug 2017
Walter W
Full Access

Background. Since the development of modern total hip replacement (THR) more than 50 years ago, thousands of devices have been developed in attempt to improve patient outcomes and prolong implant survival. Modern THR devices are often broadly classified according to their method of fixation; cemented, uncemented or hybrid (typically an uncemented acetabular component with a cemented stem). Due to early failures of THR in young active patients, the concept of hip resurfacing was revisited in the 1990's and numerous prostheses were developed to serve this patient cohort, some with excellent clinical results. Experience with metal-on-metal (MoM) bearing related issues particularly involving the ASR (DePuy Synthes, Warsaw, Indiana) precipitated a fall in the use of hip resurfacing (HR) prostheses in Australia from a peak of 30.2% in 2004 to 4.3% in 2015. The effects of poorly performing prostheses and what is now recognised as suboptimal patient selection are reflected in the AOANJRR cumulative percent revision (CPR) data which demonstrates 13.2% revision at 15 years for all resurfacing hip replacements combined; with 11 different types of hip resurfacing prostheses recorded for patients less than 55 years of age and a primary diagnosis of OA. When this data is restricted to only those prostheses currently used in Australia (BHR; Smith and Nephew, Birmingham, UK & ADEPT; MatOrtho Ltd, Surrey, UK) there is a CPR of 9.5% at 15 years for all patients. Despite these CPR results, recognition is emerging of the important distinction between MoM THR and resurfacing. Furthermore, in light of current consensus for patient selection and the surgical indications for resurfacing, a gender analysis demonstrates a CPR for females of 14.5% at 10 years compared to 3.7% for males. Similar difference for head size >50mm with 6% CPR at 10 years compared to 17.6% for head size <50mm (HR=2.15; 1.76, 2.63; p<0.001). Leading to renewed interest in resurfacing particularly in the young, active male. In addition to registry based CPR data, several studies have concluded that a true difference in mortality rates between HR and other forms of THR exists independent of age, sex or other confounding factors. We hypothesised that a difference in adjusted mortality rates between HR and other forms of THR may also be present in the Australian population. We undertook an ad hoc data report request to the AOANJRR. The data set provided was deidentified for patient, surgeon and institution and included all HR and conventional THR procedures performed for the diagnosis of primary osteoarthritis recorded in the Registry since inception in 1999. We requested mortality and yearly cumulative percent survival (CPS) of patients for primary HR and THR with sub-group analysis by the mode of fixation. There were 12,910 hip resurfacings (79% male) compared to 234,484 conventional THR (46.8% male) over the study period. When adjusted for age and gender over the 15 years of available data, there was a statistically significant difference in cumulative percent survival (CPS) between conventional THR and hip resurfacing (HR 1.66 (1.52, 1.82; p<0.001)) and between cemented THR and hip resurfacing (HR 1.96 (1.78, 2.43; p<0.001)); between uncemented THR and hip resurfacing (HR 1.58 (1.45, 1.73; p<0.001)); and between hybrid THR and hip resurfacing (HR 1.82 (1.66, 1.99; p<0.001)). When adjusted for age, gender and ASA over the 3 years data available, there was no statistically significant difference in CPS between hip resurfacing and any individual fixation type of THR. Discussion. The results demonstrate a statistically significant adjusted survival advantage for hip resurfacing compared to conventional THR and between fixation methods for THR. These findings are consistent with previous studies. While a difference in adjusted mortality rate appears to exist, we are yet to definitively determine the complex interplay of causative factors that may contribute to it


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_4 | Pages 31 - 31
1 Apr 2022
Langton D Bhalekar R Joyce T Shyam N Nargol M Pabbruwe M Su E Nargol A
Full Access

Cobalt chrome alloy is commonly used in joint replacement surgery. However, it is recognised that some patients develop lymphocyte mediated delayed type hypersensitivity (DTH) responses to this material, which may result in extensive bone and soft tissue destruction. Phase 1. United Kingdom: From an existing database, we identified extreme phenotype patient groups following metal on metal (MoM) hip resurfacing or THR: ALVAL with low wearing prostheses; ALVAL with high wear; no ALVAL with high wear; and asymptomatic patients with implants in situ for longer than ten years. Class I and II HLA genotype frequency distributions were compared between these patients’ groups, and in silico peptide binding studies were carried out using validated methodology. Phase 2. United Kingdom: We expanded the study to include more patients, including those with intermediary phenotypes to test whether an algorithm could be developed incorporating “risk genotypes”, patient age, sex and metal exposure. This model was trained in phase 3. Phase 3. United Kingdom, Australia, United States. Patients from other centres were invited to give DNA samples. The data set was split in two. 70% was used to develop machine learning models to predict failure secondary to DTH. The predictions were tested using the remaining blinded 30% of data, using time-dependent AUROCs, and integrated calibration index performance statistics. A total of 606 DNA samples, from 397 males and 209 female patients, were typed. This included 176 from patients with failed prostheses, and 430 from asymptomatic patients at a mean of >10 years follow up. C-index and ROC(t) scores suggested a high degree of discrimination, whilst the IBS indicated good calibration and further backed up the indication of high discriminatory ability. At ten years, the weighted mean survival probability error was < 4%. At present, there are no tests in widespread clinical use which use a patient's genetic profile to guide implant selection or inform post-operative management. The algorithm described herein may address this issue and we suggest that the application may not be restricted to the field of MoM hip arthroplasty


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 1 | Pages 12 - 19
1 Jan 2010
Vendittoli P Roy A Mottard S Girard J Lusignan D Lavigne M

We have updated our previous randomised controlled trial comparing release of chromium (Cr) and cobalt (Co) ions and included levels of titanium (Ti) ions. We have compared the findings from 28 mm metal-on-metal total hip replacement, performed using titanium CLS/Spotorno femoral components and titanium AlloFit acetabular components with Metasul bearings, with Durom hip resurfacing using a Metasul articulation or bearing and a titanium plasma-sprayed coating for fixation of the acetabular component. Although significantly higher blood ion levels of Cr and Co were observed at three months in the resurfaced group than in total hip replacement, no significant difference was found at two years post-operatively for Cr, 1.58 μg/L and 1.62 μg/L respectively (p = 0.819) and for Co, 0.67 μg/L and 0.94 μg/L respectively (p = 0.207). A steady state was reached at one year in the resurfaced group and after three months in the total hip replacement group. Interestingly, Ti, which is not part of the bearing surfaces with its release resulting from metal corrosion, had significantly elevated ion levels after implantation in both groups. The hip resurfacing group had significantly higher Ti levels than the total hip replacement group for all periods of follow-up. At two years the mean blood levels of Ti ions were 1.87 μg/L in hip resurfacing and and 1.30 μg/L in total hip replacement (p = 0.001). The study confirms even with different bearing diameters and clearances, hip replacement and 28 mm metal-on-metal total hip replacement produced similar Cr and Co metal ion levels in this randomised controlled trial study design, but apart from wear on bearing surfaces, passive corrosion of exposed metallic surfaces is a factor which influences ion concentrations. Ti plasma spray coating the acetabular components for hip resurfacing produces significantly higher release of Ti than Ti grit-blasted surfaces in total hip replacement


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11_Supple_A | Pages 32 - 35
1 Nov 2012
Brooks P Bershadsky B

Femoroacetabular impingement (FAI) is commonly associated with early hip arthritis. We reviewed our series of 1300 hip resurfacing procedures. More than 90% of our male patients, with an average age of 53 years, had cam impingement lesions. In this condition, there are anterior femoral neck osteophytes, and a retroverted femoral head on a normally anteverted neck. It is postulated that FAI results in collision of the anterior neck of the femur against the rim of the acetabulum, causing damage to the acetabular labrum and articular cartilage, resulting in osteoarthritis. Early treatment of FAI involves arthroscopic or open removal of bone from the anterior femoral neck, as well as repair or removal of labral tears. However, once osteoarthritis has developed, hip replacement or hip resurfacing is indicated. Hip resurfacing can re-orient the head and re-shape the neck. This helps to restore normal biomechanics to the hip, eliminate FAI, and improve range of motion. Since many younger men with hip arthritis have FAI, and are also considered the best candidates for hip resurfacing, it is evident that resurfacing has a role in these patients


The Bone & Joint Journal
Vol. 95-B, Issue 12 | Pages 1626 - 1631
1 Dec 2013
van der Weegen W Brakel K Horn RJ Hoekstra HJ Sijbesma T Pilot P Nelissen RGHH

The aim of this study was to establish the natural course of unrevised asymptomatic pseudotumours after metal-on-metal (MoM) hip resurfacing during a six- to 12-month follow-up period. We used repeated metal artefact reduction sequence (MARS)-magnetic resonance imaging (MRI), serum metal ion analysis and clinical examination to study 14 unrevised hips (mean patient age 52.7 years, 46 to 68, 5 female, 7 male) with a pseudotumour and 23 hips (mean patient age 52.8 years, 38 to 69, 7 female, 16 male) without a pseudotumour. The mean post-operative time to the first MARS-MRI scan was 4.3 years (2.2 to 8.3), and mean time between the first and second MARS-MRI scan was eight months (6 to 12). At the second MRI scan, the grade of severity of the pseudotumour had not changed in 35 hips. One new pseudotumour (Anderson C2 score, moderate) was observed, and one pseudotumour was downgraded from C2 (moderate) to C1 (mild). In general, the characteristics of the pseudotumours hardly changed. Repeated MARS-MRI scans within one year in patients with asymptomatic pseudotumours after MoM hip resurfacing showed little or no variation. In 23 patients without pseudotumour, one new asymptomatic pseudotumour was detected. This is the first longitudinal study on the natural history of pseudotumours using MARS-MRI scans in hip resurfacing, and mirrors recent results for 28 mm diameter MoM total hip replacement. Cite this article: Bone Joint J 2013;95-B:1626–31


The Bone & Joint Journal
Vol. 101-B, Issue 10 | Pages 1186 - 1191
1 Oct 2019
Amstutz HC Le Duff MJ

Aims. In previous studies, we identified multiple factors influencing the survivorship of hip resurfacing arthroplasties (HRAs), such as initial anatomical conditions and surgical technique. In addition, the University of California, Los Angeles (UCLA) activity score presents a ceiling effect, so a better quantification of activity is important to determine which activities may be advisable or detrimental to the recovered patient. We aimed to determine the effect of specific groups of sporting activities on the survivorship free of aseptic failure of a large series of HRA. Patients and Methods. A total of 661 patients (806 hips) representing 77% of a consecutive series of patients treated with metal-on-metal hybrid HRA answered a survey to determine the types and amounts of sporting activities they regularly participated in. There were 462 male patients (70%) and 199 female patients (30%). Their mean age at the time of surgery was 51.9 years (14 to 78). Their mean body mass index (BMI) was 26.5 kg/m. 2. (16.7 to 46.5). Activities were regrouped into 17 categories based on general analogies between these activities. Scores for typical frequency and duration of the sessions were used to quantify the patients’ overall time spent engaging in sporting activities. Impact and cycle scores were computed. Multivariable models were used. Results. We found no association between any category of activity and a decrease in survivorship. Impact and hip cycle scores also failed to show any association with revision for aseptic failure or wear. Conclusion. Return to sporting activities after surgery is safe for patients treated with well-designed and well-implanted HRA. Cite this article: Bone Joint J 2019;101-B:1186–1191


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_16 | Pages 54 - 54
1 Dec 2021
Maslivec A Ng KCG Cobb J
Full Access

Abstract. Objectives. Although hip replacement and resurfacing procedures both aim to restore mobility, improve joint function, and relieve pain, it is unclear how each differ in terms of gait mechanics and if they are affected by varying walking speeds. We compared limb symmetry and ground reaction force (GRF) profiles between bilateral total hip arthroplasty patients (THA), bilateral hip resurfacing arthroplasty patients (HRA), and healthy control participants (CON) during level-treadmill walking at different speeds. Methods. Bilateral THA and bilateral HRA patients (nTHA = 15; nHRA = 15; postoperative 12–18 months), and age-, mass-, and height-matched CON participants (nCON = 20) underwent gait analysis on an instrumented treadmill. Walking trials started at 4 km/h and increased in 0.5 km/h increments until top walking speed (TWS) was achieved. Gait symmetry index (SI = 0% for symmetry) was assessed between limbs during weight-acceptance, mid-stance and push-off phases of gait; and vertical GRFs were captured for the normalised stance phase using statistical parametric mapping (SPM; CI = 95%). Results. THA had a significantly lower TWS (6.51 ± 0.06 km/h) compared to HRA (7.09 ± 0.07 km/h, p = 0.01) and CON (7.15 km/h ± 0.06, p = 0.02). There were no SI differences between groups nor between walking speeds (SI < 5%). There were no GRF differences between groups at slower walking speeds (4.0–5.0 km/h). However, at 5.5 and 6 km/h, THA had lower GRF at the push-off phase (0.88 ± 0.09 N/BW), compared to HRA (1.06 ± 0.08 N/BW, p = 0.01) and CON (1.04 ± 0.02 N/BW, p = 0.01). Conclusions. The main finding was that HRA patients demonstrated restored gait function and similar walking profiles to CON participants at any speed. With a diverging gait profile, walking speeds over 5.5 km/h provided a functional challenge for THA patients


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_14 | Pages 37 - 37
1 Nov 2021
Girard J
Full Access

The management of prosthetic joint infection (PJI) has been widely performed for total hip arthroplasties (THA), but none has compared it with hip resurfacing arthroplasty (RSA). We also carried out a retrospective case-control study comparing the surgical treatment of PJI by surgical debridement and implant retention between RSA and THA in order to clarify whether there was a difference in terms of (1) successful healing of PJI (2) functional scores after recovery (3) risk factors for recurrence of PJI. Our hypothesis was that simple debridement with prosthesis retention regardless of the timeframe allowed to obtain a higher success rate for RSA compared to THA. From 2010 to 2018, a single-center case-control study based on 3056 RSA found 13 PJI were age-matched (based on the 139 THA PJI treated) with 15 THA PJI (mean age of 53 years old (47–58) for THA and 59 (45–66) for RSA (p=0.34)). We compared their survival (absence of infectious recurrence) and the means differences between the 2 groups (demographical, clinical and biological data). There was no difference between the 2 groups concerning: age (p=0.3), BMI (p=0.4), initial diagnosis (p=0.4), operating time for primary surgery (p=0.3), the presence of a postoperative hematoma (p=0.4), the type of bacteria (p=0.5), the total duration of antibiotic therapy (p=0.9) and the type of antibiotic therapy (p=0.6). Early postoperative infections (less than 6 weeks) occurred in 7/13 RSA cases (54%) compared to 11/15 THA cases (73%). At the mean follow-up of 5 years (2–7), the success rate without recurrence was significantly higher in the RSA group 100% versus 66.7% (10/15) for the THA group (p=0.044). At the last follow-up, the Oxford Hip Score was higher in the RSA versus THA group's (14 versus 22 p=0.004). Simple surgical debridement an RSA without changing implants after PJI can be done regardless of the time to onset of infection. This is secondary to the absence of metaphyseal bone invasion and the low content of joint fluid


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 115 - 115
1 Feb 2017
Chun Y Cho Y Lee C Bae C Rhyu K
Full Access

Purpose. This study was performed to evaluate clinical and radiographic outcomes of Hip Resurfacing Arthroplasty for treatment of haemophilic hip arthropathy. Material & Method. Between 2002 and 2013, 17 cases of hip resurfacing arthroplasties were performed in 16 haemophilic patients (13 cases of haemophilia A, 2 cases of haemophilia B, 2 cases of von Willebrand disease). The average age of the patients was 32.5(range: 18∼52) years. The average follow up period from the operation was 6.3 (range: 2∼13) years. In this study, the subjects that completed follow-up were composed of 5 cases composed of patients who were treated with Conserve plus. ®. hip resurfacing system, 5 cases composed of patients who were treated with Durom. ®. hip resurfacing system, 4 cases who were treated with ASR. ®. hip resurfacing system, and 3 cases who were treated with Birmingham. ®. hip resurfacing system. The Modified Harris hip score, the range of motion of the hip joint, perioperative coagulation factor requirements and complications associated with bleeding were evaluated as part of the clinical assessment. For the radiographic assessment, fixation of component, presence of femoral neck fracture, osteolysis, loosening and other complications were evaluated. Results. The modified Harris hip score improved from 65.4(47–80) points before surgery to 97.8(90–100) points at the last follow-up. The average further flexion improved from 103° (70–135) to 110°(80–130) after surgery. The average abduction improved from 22.4° (0–45) to 41.3° (20–50) after surgery. All the patients showed a significant reduction in pain. The mean requirement of factor VIII reduced from 2470 units per month before surgery to 1125 units per month at the time of the last follow-up. However, in the case of high-titer inhibitor to factor VIII, haemophilia B, von Willebrand disease, the average monthly factor requirement was not changed due to bleeding episode of other joints. There was two cases of re-bleeding. There were no femoral neck fracture, no osteolysis, and no implant loosening in last follow up. Conclusion. Hip resurfacing arthroplasty for haemophilic hip arthropathy in patients with mild deformity or relatively preserved range of the hip joint motion can bring reliable pain relief, functional improvement, and reduction of factor requirement for over two years follow-up study. However, bleeding-associated complications are a cause for concern, especially for patients with antibodies against coagulation factors


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_11 | Pages 23 - 23
1 Jun 2016
Singh S
Full Access

Introduction. In the early 2000s hip resurfacing became an established bone conserving hip arthroplasty option particularly for the fit and active patient cohort. The performance of second-generation metal-on-metal bearings had led to the reintroduction of hip resurfacing. The Birmingham Hip resurfacing (BHR) was introduced in 1997. This was followed by a number of different designs of the hip resurfacing. The Durom hip resurfacing was introduced in 2001. These two designs had different metallurgical properties, design parameters particularly clearance and different implantation techniques. Data from joint registries show that both prosthesis perform well. Objectives. Our objective was to perform a retrospective survival analysis comparing the Birmingham to the Durom hip resurfacing and analyse the mode of failures of the cases revised. Methods. Data was collected prospectively but analysed retrospectively. The two cohorts comprised patients treated by two senior surgeons at different units. The follow up range was 1 to 14 years with a mean of 10 years. The end-point was revision for any cause. However this was further substratified. Results. The outcome of all patients was known. The two cohorts exhibited no significant difference in demographics. No failures in either cohort were attributed to adverse reaction to metal debris. Revision for any cause was analysed by plotting Kaplan-Meier Survival curves. The Durom cohort (n=273) had 5 deaths and 9 revisions. The Birmingham cohort (n=567) had 5 deaths and 22 revisions. The Kaplan-Meier survival curves for the two resurfacing designs were different. The Durom cohort demonstrated a concave curve with more early failures. This was contrary to the BHR's convex curve with higher incidence of late failures. We analysed the data by substratifying into failure of femoral or acetabular component and neck fractures. Conclusions. The Kaplan-Meier survival analysis demonstrates that the Durom hip resurfacings had a higher rate of early failure. However extrapolation of the curves suggests that the Durom may have a superior long term survival compared to the BHR. We postulate that this may be due to the femoral implantation technique with less late failures in Duroms and an apparent acceleration of failures in BHR cohort around the ten year stage. Joint registry data also reflect this pattern


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 112 - 112
1 Apr 2019
Farrier A Manning W Moore L Avila C Collins S Holland J
Full Access

INTRODUCTION. The cup component of modern resurfacing systems are often coated creating a cementless press-fit fixation in the acetabulum based on surgical under-reaming, also enabling osseoconduction/integration. Due to the higher density of cortical bone along the antero-superior and postero-inferior regions of the acetabulum, the greatest forces occur between the anterior and posterior columns of the pelvis. This produces pinching of the implant that can result in deformation of the cup. Metal shell/modularpress-fit acetabular cups are susceptible to substantial deformation immediately after implantation. This deformation may affect the lubrication, producing point loading and high friction torques between the head and the cup that increase wear and may lead to head clamping and subsequent cup loosening. We sought to test a novel ceramic on ceramic (CoC) hip resurfacing system that should allay any concerns with the Adverse Reaction to Metal Debris associated with metal on metal (MoM) resurfacing devices. AIM. We sought to quantify the deformation of a novel CoC hip-resurfacing cup after implantation, using a standard surgical technique in a cadaveric model, and compare to the MoM standard. We also assessed if the design clearances proposed for this CoC hip resurfacing implant are compatible with the measured deformations, allowing for an adequate motion of the joint. METHODS. The pelvis from four fresh frozen cadavers were placed into the lateral position. One surgeon with extensive experience in hip resurfacing surgery (JH) prepared all the pelvises for implantation using a posterior approach to the joint and sequential reaming of the acetabulum to 1mm below the implant outer diameter. The acetabulum components were then impacted into the prepared pelvis. We used four ceramic and four metal implants of equal and varying size. (2 × (40/46mm, 44/50mm, 50/56mm, 52/58mm)). The acetabulum cup bearing surface diameter and deformation was measured using a GOM-ATOS optical high precision 3D scanner. 3-Dimensional measurements were taken pre-implantation, immediately after and at 30 minutes following implantation. Two techniques were used to analyse the 3D images: by maximum inscribed diameter and by radial segments. These were compared to the known articulating surface clearance values. RESULTS. The diameter of the cups in both metal and ceramic systems was reduced after implantation when analysing by maximum inscribed diameter and by radial segments. This deformation was maintained at 30 minutes. We can infer there is no significant bone stress relaxation effect following implantation. On ceramic cups, the deformation was larger in larger sizes. However, the 44/50 (the second smallest cup) deformed the least. Despite this, the difference in deformation between these two sizes is minimal. The deformation of sizes 50/56 and 52/58 was equivalent. For the metal cups, there was not a clear correlation between the cup size and the deformation. The largest cup size had the same deformation as the smallest size. CONCLUSIONS. The deformation following implantation of the cup component in a ceramic acetabulum resurfacing behave similarly to a metal implant. Cup deformation measured after implantation is minimal when compared to the minimum design clearance in both systems


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 110 - 110
1 Apr 2019
Farrier A Manning W Moore L Avila C Collins S Holland J
Full Access

INTRODUCTION. Experience with Metal on Metal (MoM) hip resurfacing devices has shown adequate cementation of the femoral head is critical for implant survival. Bone necrosis can be caused by the temperature change in the peri-prosthetic bone whilst the cement cures during implantation. This can lead to implant loosening, head/neck fracture and implant failure. During the implantation it is known that implants change shape potentially altering joint clearance and causing loosening. Given the history of Metal on Metal implant failure due adverse tissue reactions from Cobalt and Chromium particles we sought to test a novel Ceramic on Ceramic (CoC) bearing which may mitigate such problems. AIM. We set out to compare the behaviour of a novel ceramic femoral head component to a standard metal component in a hip resurfacing system after cemented implantation in a physiological warmed cadaveric model. Our first aim was to perform heat transfer analysis: To document time to, and extent of, maximum temperature change on the metal/ceramic surface and inside the resurfaced femoral head bone. Our second aim was to perform a dimensional analysis: To document any resulting deformation in the metal/ceramic femoral head bearing diameter during cementation. METHODS. Femurs were removed from four fresh frozen cadavers and placed into a vice. One surgeon with extensive experience in hip resurfacing surgery (JH) prepared all the femoral heads for implantation. Cadaveric warming was performed using a thermostatic silicone heating element to achieve near physiological conditions (28–32°C). The femur components were then implanted onto the femur head using Simplex P (Stryker) low viscosity bone cement. We used four ceramic (ReCerf™) and four metal implants (ADEPT®) of equal and varying size. (2 × (42mm, 46mm, 48mm, 50mm). Temperature change was measured using a thermometer probe placed into femur neck and head from the lateral side with position check using an image intensifier. Implant surface temperature was measured using a calibrated infrared thermometer at a standard 30cm distance. Head bearing surface diameter was measured using a micro-meter. Measurements were taken 2mins pre-implantation and sequentially at 1, 5, 10, 15, 20, 25 and 30 minutes after implantation. RESULTS. The bone temperature change for both metal and ceramic implants fell after implantation and then increased. The implant surface temperature increased and then stabilised for both implants. There was no significant difference in the bone or surface temperature change between metal and ceramic implants. The bearing surface diameter change was greater in the metal implants, although this was not significant. All implants returned to within one µm of initial surface diameter at 30 minutes. CONCLUSIONS. The femoral head component of a ceramic resurfacing has similar properties for surface temperature change following implantation to conventional MOM resurfacing. The periprosthetic bone is not at risk of significant heat necrosis during cementation (max temp 32°C). The deformation following implantation was similar for both metal and ceramic components. All implants returned to near initial diameter. The deformation and temperature changes following implantation of a ceramic resurfacing are similar to a metal implant


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_10 | Pages 27 - 27
1 Aug 2021
Edwards T Keane B Garner A Logishetty K Liddle A Cobb J
Full Access

This study investigates the use of the Metabolic Equivalent of Task (MET) score in a hip arthroplasty population and its ability to capture additional benefit beyond the maximum Oxford Hip Score (OHS). OHS, EuroQol-5D index (EQ-5D), and the MET were prospectively recorded in 221 primary hip arthroplasty procedures pre-operatively and at 1-year. The distribution was examined reporting the presence of ceiling & floor effects. Validity was assessed correlating the MET with the other scores using Spearman's rank and determining responsiveness using the standardised response mean (SRM). A subgroup of 93 patients scoring 48/48 on the OHS were analysed by age group, sex, BMI and pre-operative MET using the other two metrics to determine if differences could be established despite all scoring identically on the OHS. 117 total hip and 104 hip resurfacing arthroplasty operations were included. Mean age was 59.4 ± 11.3. Post-operatively the OHS and EQ-5D demonstrate significant negatively skewed distributions with ceiling effects of 41% and 53%, respectively. The MET was normally distributed post-operatively with no ceiling effect. Weak-moderate but statistically significant correlations were found between the MET and the other two metrics both pre & post-operatively. Responsiveness was excellent, SRM for OHS: 2.01, EQ-5D: 1.06 and MET: 1.17. In the 48/48 scoring subgroup, no differences were found comparing groups with the EQ-5D, however significantly higher MET scores were demonstrated for patients aged <60 (12.7 vs 10.6, p=0.008), male patients (12.5 vs 10.8, p=0.024) and those with pre-operative MET scores >6 (12.6 vs 11.0, p=0.040). The MET is normally distributed in patients following hip arthroplasty, recording levels of activity which are undetectable using the OHS. As a simple, valid activity metric, it should be considered in addition to conventional PROMs in order to capture the entire benefit experienced following hip arthroplasty


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_11 | Pages 4 - 4
1 Aug 2018
Cobb J Clarke S Halewood C Wozencroft R Jeffers J Logishetty K Keane B Johal H
Full Access

We aimed to demonstrate the clinical safety of a novel anatomic cementless ceramic hip resurfacing device. Concerns around the safety of metal on metal arthroplasty have made resurfacing less attractive, while long term function continues to make the concept appealing. Biolox Delta ceramic is now used in more than 50% of all hip arthroplasties, suggesting that it's safety profile is acceptable. We wondered if a combination of these concepts might work?. The preclinical testing of anatomic hip resurfacing device developed by our group was presented last year. A twenty patient safety study was designed. Patients had to be between the ages of 18 and 70. The initial size range was restricted to femoral heads between 46 and 54, representing the common sizes of hip resurfacing. The primary outcomes were clinical safety, PROMs and radiological control. Secondary outcomes include CTRSA and metal ion levels. 20 patients were recruited, aged 30–69. 7 were women and 13 were men. There were no operative adverse events in their operations undertaken between September 2017 and February 2018. One patient had a short episode of atrial fibrillation on the second postoperative day, and no other complications. At three months the median oxford hip score had risen from 27 (range 14–38) to 46 (31–48). Cobalt and chromium levels were almost undetectable at 3 months. Fixation appeared satisfactory in all patients, with no migration detected in either component. CTRSA is in process. The initial safety of a novel cementless ceramic resurfacing device is demonstrated by this data. The 10 year, 250 case efficacy study will continue in 5 other European centres


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_10 | Pages 52 - 52
1 May 2016
Stiegel K Ismaily S Noble P
Full Access

Introduction. Patients who undergo hip resurfacing, total hip arthroplasty (THA), and total knee arthroplasty (TKA) are frequently assessed post-operatively using objective scoring indices. A small yet significant percentage of these patients report specific unfulfilled functions following surgery, indicating unmet expectations. The purpose of this study was to examine the types of functional deficits reported for each class of surgery, how frequently these limitations occur, and the demographic of patients who experience/report these limitations. Methods. Four groups of subjects were enrolled in this study: (i) 111 hip resurfacing patients at an average of 14 months after resurfacing, (ii) 170 patients at an average of 16 months post-primary THA, (iii) 61 patients at an average of 12 months post-primary TKA, and (iv) 64 control subjects with no history of hip or knee surgery or pathology. Each participant completed a self-administered Hip Function Questionnaire, Knee Function Questionnaire, or Hip Resurfacing Questionnaire which assessed each subject's overall satisfaction and expectations following surgery. The questionnaires included numerical scores of post-operative function as well as an open-ended question which inquired “Is there anything your knee/hip keeps you from doing?”. Results. A population of patients self-reported specific functional deficits after surgery, including 29 (26.1%) resurfacing, 5 (2.9%) THA, and 32 (52.5%) TKA. The unfulfilled functions varied based on the procedure, with most resurfacing and THA patients reporting trouble with running/jogging, while TKA patients experienced difficulty kneeling. Patients who reported functional deficits also tended to endorse lower overall satisfaction levels after surgery; the mean satisfaction score for hip resurfacing in those who reported deficits was 4.03 (scale of 1–5) versus 4.50 (p=0.09) in those who denied a functional deficit, 2.20 versus 4.47 (p=0.003) in THA patients, and 4.10 versus 4.36 (p=0.35) in TKA patients. The demographic of patients who reported limitations varied based on the type of surgery. After hip resurfacing 19.0% (4/21) of female patients reported specific deficits compared to 27.3% (23/84) of male patients; 6.1% (5/81) of female THA patients reported compared to 0% (0/84) of males, and 48.6% (18/37) of female TKA patients reported compared to 58.3% (14/24) of males. The mean age of those who reported deficits versus those who did not report deficits was not significant. Conclusions. Despite advances in arthroplasty and resurfacing techniques, a significant portion of patients are experiencing functional limitations following hip resurfacing, TKA, and THA procedures. The frequency and types of limitations reported vary based on the surgery, with TKA patients reporting deficits with the highest frequency and THA patients reporting with the lowest frequency. The gender of the patient appears to play a role in whether specific functional deficits are reported or not, with female patients more likely to report after THA and male patients slightly more likely to report after either hip resurfacing or TKA. Summary. A small portion of hip resurfacing, THA, and TKA patients report specific unfulfilled functions following surgery. The frequency and types of deficits, and the demographic of patients reporting them, varies based on the procedure


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_7 | Pages 21 - 21
1 Apr 2017
Brooks P
Full Access

It's easy to say that hip resurfacing is a failed technology. Journals and lay press are replete with negative reports concerning metal-on-metal bearing failures, destructive pseudotumors, withdrawals and recalls. Reviews of national joint registries show revision risks with hip resurfacing exceeding those of traditional total hip replacement, and metal bearings fare worst among all bearing couples. Yet, that misses the point. Modern hip resurfacing was never meant to replace total hip replacement (THR). It was intended to preserve bone in young patients who would be expected to need multiple revisions due to their youth and high-demand activities. The stated goal of the developers of the Birmingham Hip Resurfacing (BHR) was to delay THR by 10 years. In the two decades that followed the release of BHR, this goal has been met and exceeded. Much has been learned about indications, patient selection, and surgical technique. We now know that this highly specialised, challenging procedure is best indicated in the young, active male with osteoarthritis, as a complementary, not competitive procedure, to THR. Resurfacing has many advantages. First and foremost, it saves bone, on the day of surgery, and over the next several years by preventing stress shielding. Dislocations are very rare. Leg length discrepancy and changes in offset are avoided. Post-operative activity, including heavy manual labor and contact sports, is unrestricted. More normal loading of the femur and joint stability has allowed professional athletes to regain their careers. Femoral side revisions, if necessary, are simple total hips, and dual mobility constructs allow one to keep the socket. Adverse reactions to metal debris (ARMD), including pseudotumors, have generated great concern. Initially described only in women, it was unclear whether the etiology was allergy, toxicity, or inflammation. A better understanding of the wear properties of the bearing, and its relation to size, anteversion, hip dysplasia and metallurgy, along with retrieval analysis, allow us to conclude that it is excessive wear due to edge loading which is the fundamental mechanism for the vast majority of ARMD. Thus, patient selection, implant selection and surgical technique, the orthopaedic triad, are paramount. What has been most impressive are the truly exceptional results in young, active men. The worst candidates for THR turn out to be the best candidates for resurfacing. The ability to return to full, unrestricted activity is just as important to these patients as the spectacular survivorship in centers specializing in resurfacing. If they are unlucky and face a revision, they are not facing the life-changing outcomes of a long revision femoral stem. So if the best indication for hip resurfacing is the young, active male, let's look at the results of resurfacing these patients in centers with high volumes, using devices with a good track record, such as BHR. Several centers around the world report 10–18 year success rates of BHR in males under 50 at 98–100%. Return to athletics is routinely achieved, and even professional athletes have regained their careers. Hip resurfacing doesn't have to be better than THR to be popular among patients. Just the idea of saving all that bone makes it attractive. In the young active male, however, the results exceed those of THR, while leaving better revision options for the future. This justifies its continued use in this challenging patient population


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 60 - 60
1 Feb 2017
Khan H Meswania J Riva F Pressacco M Panagiotidou A Coathup M Blunn G
Full Access

Background. Hip resurfacing has advantages for the young active patient with arthritis; maintaining a large range of motion, preserving bone stock, and reduced dislocation risk. However high serum metal ion levels with metal-on-metal resurfacing, and their clinical implications, has led to a decline in the use of hip resurfacing. Ceramic bearing surfaces display the lowest frictional torque and excellent wear rates. Recent developments have enabled large, strong ceramic materials to be used as resurfacing components. Any wear debris that is generated from these articulations is inert. However an all-ceramic hip resurfacing could be at risk of fracture at the head-stem junction. A new ceramic hip resurfacing system with a titanium-ceramic modular taper junction has been developed. The introduction of a taper introduces the potential for fretting corrosion; we sought to determine the extent of this in an in-vitro model, and compared this prosthesis to the conventional 12/14 titanium-cobalt chrome (Ti6Al4V-CoCr) taper junction. Methods. To simulate the gait cycle, sinusoidal cyclical loads between 300N-2300N, at a frequency of 3Hz, were applied to different head-neck offsets generating different bending moments and torques. The effect of increasing the bending moment and frictional torque were tested separately. Furthermore, the resurfacing head was mounted in a fixture held with just the stem, thus representing complete bone resorption under the head. An electrochemical assessment using potentiostatic tests at an applied potential of 200mV, was used to measure the fretting current (μA) and current amplitude (μA). In a short-term 1000 cycle test, six neck lengths (short to xxx-long) of the Ti6Al4V-CoCr taper were compared to the standard neutral (concentric), and 3mm A/P offset stem options for the resurfacing design. To represent frictional torque, four increments of increasing torque (2-4-6-8Nm) were applied to both tapers. In a long term test with the resurfacing stem, the worst-case scenario of the eccentric offset option and 8Nm of torque were applied, and potentiostatic measurements were taken every million cycles, up to 10 million cycles. Results. For bending moment through the centre of the head, the standard neutral resurfacing taper displayed equivalent fretting current (1.35μA) compared to its conventional taper equivalent, the short 12/14 Ti6Al4V-CoCr taper (Fig. 1a). That was despite the bending moment through the resurfacing taper being higher due to the offset nature of its taper in relation to the centre of the head. For applied torque, the resurfacing taper displayed reduced average fretting current and average maximum fretting current when compared to the conventional taper (Fig. 1b), though this did not reach statistical significance (Kruskal-Wallis test). Under long term testing for worst-case bending and torque, the resurfacing taper displayed low fretting currents (<2μA and <5μA respectively) with no significant variance of the median values across 10 million cycles (Figs. 2 and 3). Conclusion. When compared to the gold-standard taper junction, the LIMA ceramic hip resurfacing displays equivalent fretting corrosion for bending moment and improved fretting corrosion for frictional torque. Across long term testing, stable and low fretting currents at this taper junction highlight its potential in clinical use


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_3 | Pages 22 - 22
1 Feb 2017
Huixiang W Newman S Jones G Sugand K Cobb J Auvinet E
Full Access

Introduction. Because of the low cost and easy access, surgical video has become a popular method of acquiring surgical skills outside operating rooms without disrupting normal surgical flow. However, currently existing video systems all use a single point of view (POV). Some complex orthopedic procedures, such as joint replacement, require a level of accuracy in several dimensions. So single and fixed POV video may not be enough to provide all the necessary information for educational and training purposes. The aim of our project was to develop a novel multiple POV video system and evaluate its efficacy as an aid for learning joint replacement procedure compared with traditional method. Materials and Methods. Based on the videos of a hip resurfacing procedure performed by an expert orthopedic surgeon captured by 8 cameras fixed all around the operating table, we developed a novel multiple POV video system which enables users to autonomously switch between optimal viewpoints (Figure 1). 30 student doctors (undergraduate years 3–5 and naive to hip resurfacing procedure) were recruited and randomly allocated to 2 groups: experiment group and control group, and were assigned to learn the procedure using multiple or single POV video systems respectively. Before learning they were first asked to complete a multiple choicetest designed using a modified Delphi technique with the advice and feedback sought from 4 experienced orthopedic surgeons to test the participants' baseline knowledge of hip resurfacing procedure. After video learning, they were asked to answer the test again to verify their gained information and comprehension of the procedure, followed by a 5-point Likert-scale questionnaire to demonstrate their self-perception of confidence and satisfaction with the learning experience. The scores in the 2 tests and in the Likert-scale questionnaire were compared between 2 groups using Independent-Samples t-test (for normally distributed data) or Mann-Whitney U test (for non-normally distributed data). Statistical significance was set as p<0.05. Results. There was no significant difference regarding the ages of the participants between the experiment group (22.27 ± 1.79 years) and the control group (23.00 ± 1.56 years) (p value=0.242). The 10 questions in the test were divided into 3 subcategories: 4 questions regarding spatial awareness, 4 regarding operation details and 2 regarding sequence comprehension. There was no significant difference between both cohorts in the baseline test scores (for overall scores or scores in any subcategory) before video-learning, thus ensuring homogeneity. Yet, there was a 31.6–75.4% significantly (p<0.033) higher test score after video learning in the experiment group compared with the control group (for overall, spatial awareness and operation details scores) (Figure 2). The mean Likert-scale questionnaire score in the experiment group was also 32% significantly greater than the control group (Figure 3). Conclusion. Trainees could gain better knowledge and comprehension of hip resurfacing procedure and show higher confidence and satisfaction after learning using the novel multiple POV video system compared with traditional single POV video. The novel system could serve as an effective tool for teaching hip resurfacing procedure before trainees proceed to the real operating room. For figures, please contact authors directly