Advertisement for orthosearch.org.uk
Results 1 - 28 of 28
Results per page:
The Bone & Joint Journal
Vol. 106-B, Issue 5 Supple B | Pages 118 - 124
1 May 2024
Macheras GA Argyrou C Tzefronis D Milaras C Tsivelekas K Tsiamtsouris KG Kateros K Papadakis SA

Aims. Accurate diagnosis of chronic periprosthetic joint infection (PJI) presents a significant challenge for hip surgeons. Preoperative diagnosis is not always easy to establish, making the intraoperative decision-making process crucial in deciding between one- and two-stage revision total hip arthroplasty (THA). Calprotectin is a promising point-of-care novel biomarker that has displayed high accuracy in detecting PJI. We aimed to evaluate the utility of intraoperative calprotectin lateral flow immunoassay (LFI) in THA patients with suspected chronic PJI. Methods. The study included 48 THAs in 48 patients with a clinical suspicion of PJI, but who did not meet European Bone and Joint Infection Society (EBJIS) PJI criteria preoperatively, out of 105 patients undergoing revision THA at our institution for possible PJI between November 2020 and December 2022. Intraoperatively, synovial fluid calprotectin was measured with LFI. Cases with calprotectin levels ≥ 50 mg/l were considered infected and treated with two-stage revision THA; in negative cases, one-stage revision was performed. At least five tissue cultures were obtained; the implants removed were sent for sonication. Results. Calprotectin was positive (≥ 50 mg/l) in 27 cases; out of these, 25 had positive tissue cultures and/or sonication. Calprotectin was negative in 21 cases. There was one false negative case, which had positive tissue cultures. Calprotectin showed an area under the curve of 0.917, sensitivity of 96.2%, specificity of 90.9%, positive predictive value of 92.6%, negative predictive value of 95.2%, positive likelihood ratio of 10.6, and negative likelihood ratio of 0.04. Overall, 45/48 patients were correctly diagnosed and treated by our algorithm, which included intraoperative calprotectin measurement. This yielded a 93.8% concordance with postoperatively assessed EBJIS criteria. Conclusion. Calprotectin can be a valuable tool in facilitating the intraoperative decision-making process for cases in which chronic PJI is suspected and diagnosis cannot be established preoperatively. Cite this article: Bone Joint J 2024;106-B(5 Supple B):118–124


The Bone & Joint Journal
Vol. 104-B, Issue 3 | Pages 311 - 320
1 Mar 2022
Cheok T Smith T Siddiquee S Jennings MP Jayasekera N Jaarsma RL

Aims. The preoperative diagnosis of periprosthetic joint infection (PJI) remains a challenge due to a lack of biomarkers that are both sensitive and specific. We investigated the performance characteristics of polymerase chain reaction (PCR), interleukin-6 (IL6), and calprotectin of synovial fluid in the diagnosis of PJI. Methods. We performed systematic search of PubMed, Embase, The Cochrane Library, Web of Science, and Science Direct from the date of inception of each database through to 31 May 2021. Studies which described the diagnostic accuracy of synovial fluid PCR, IL6, and calprotectin using the Musculoskeletal Infection Society criteria as the reference standard were identified. Results. Overall, 31 studies were identified: 20 described PCR, six described IL6, and five calprotectin. The sensitivity and specificity were 0.78 (95% confidence interval (CI) 0.67 to 0.86) and 0.97 (95% CI 0.94 to 0.99), respectively, for synovial PCR;, 0.86 (95% CI 0.74 to 0.92), and 0.94 (95% CI 0.90 to 0.96), respectively, for synovial IL6; and 0.94 (95% CI 0.82 to 0.98) and 0.93 (95% CI 0.85 to 0.97), respectively, for synovial calprotectin. Likelihood ratio scattergram analyses recommended clinical utility of synovial fluid PCR and IL6 as a confirmatory test only. Synovial calprotectin had utility in the exclusion and confirmation of PJI. Conclusion. Synovial fluid PCR and IL6 had low sensitivity and high specificity in the diagnosis of PJI, and is recommended to be used as confirmatory test. In contrast, synovial fluid calprotectin had both high sensitivity and specificity with utility in both the exclusion and confirmation of PJI. We recommend use of synovial fluid calprotectin studies in the preoperative workup of PJI. Cite this article: Bone Joint J 2022;104-B(3):311–320


The Bone & Joint Journal
Vol. 99-B, Issue 5 | Pages 660 - 665
1 May 2017
Wouthuyzen-Bakker M Ploegmakers JJW Kampinga GA Wagenmakers-Huizenga L Jutte PC Muller Kobold AC

Aims . Recently, several synovial biomarkers have been introduced into the algorithm for the diagnosis of a prosthetic joint infection (PJI). Alpha defensin is a promising biomarker, with a high sensitivity and specificity, but it is expensive. Calprotectin is a protein that is present in the cytoplasm of neutrophils, is released upon neutrophil activation and exhibits anti-microbial activity. Our aim, in this study, was to determine the diagnostic potential of synovial calprotectin in the diagnosis of a PJI. Patients and Methods. In this pilot study, we prospectively collected synovial fluid from the hip, knee, shoulder and elbow of 19 patients with a proven PJI and from a control group of 42 patients who underwent revision surgery without a PJI. PJI was diagnosed according to the current diagnostic criteria of the Musculoskeletal Infection Society. Synovial fluid was centrifuged and the supernatant was used to measure the level of calprotectin after applying a lateral flow immunoassay. . Results. The median synovial calprotectin level was 991 mg/L (interquartile range (IQR) 154 to 1787) in those with a PJI and 11 mg/L (IQR 3 to 29) in the control group (p < 0.0001). Using a cut-off value of 50 mg/L, this level showed an excellent diagnostic accuracy, with an area under the curve of 0.94. The overall sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) was 89%, 90%, 81% and 95% respectively. The NPV was 97% in the nine patients with a chronic PJI. . Conclusion . Synovial calprotectin may be a valuable biomarker in the diagnosis of a PJI, especially in the exclusion of an infection. With a lateral flow immunoassay, a relatively rapid quantitative diagnosis can be made. The measurement is cheap and is easy to use. . Cite this article: Bone Joint J 2017;99-B:660–5


Bone & Joint Research
Vol. 9, Issue 5 | Pages 202 - 210
1 May 2020
Trotter AJ Dean R Whitehouse CE Mikalsen J Hill C Brunton-Sim R Kay GL Shakokani M Durst AZE Wain J McNamara I O’Grady J

Aims. This pilot study tested the performance of a rapid assay for diagnosing prosthetic joint infection (PJI), which measures synovial fluid calprotectin from total hip and knee revision patients. Methods. A convenience series of 69 synovial fluid samples from revision patients at the Norfolk and Norwich University Hospital were collected intraoperatively (52 hips, 17 knees) and frozen. Synovial fluid calprotectin was measured retrospectively using a new commercially available lateral flow assay for PJI diagnosis (Lyfstone AS) and compared to International Consensus Meeting (ICM) 2018 criteria and clinical case review (ICM-CR) gold standards. Results. According to ICM, 24 patients were defined as PJI positive and the remaining 45 were negative. The overall accuracy of the lateral flow test compared to ICM was 75.36% (52/69, 95% CI 63.51% to 84.95%), sensitivity and specificity were 75.00% (18/24, 95% CI 53.29% to 90.23%) and 75.56% (34/45, 95% CI 60.46% to 87.12%), respectively, positive predictive value (PPV) was 62.07% (18/29, 95% CI 48.23% to 74.19%) and negative predictive value (NPV) was 85.00% (34/40, 95% CI 73.54% to 92.04%), and area under the receiver operating characteristic (ROC) curve (AUC) was 0.78 (95% CI 0.66 to 0.87). Patient data from discordant cases were reviewed by the clinical team to develop the ICM-CR gold standard. The lateral flow test performance improved significantly when compared to ICM-CR, with accuracy increasing to 82.61% (57/69, 95% CI 71.59% to 90.68%), sensitivity increasing to 94.74% (18/19, 95% CI 73.97% to 99.87%), NPV increasing to 97.50% (39/40, 95% CI 85.20% to 99.62%), and AUC increasing to 0.91 (95% CI 0.81 to 0.96). Test performance was better in knees (100.00% accurate (17/17, 95% CI 80.49% to 100.00%)) compared to hips (76.92% accurate (40/52, 95% CI 63.16% to 87.47%)). Conclusion. This study demonstrates that the calprotectin lateral flow assay could be an effective diagnostic test for PJI, however additional prospective studies testing fresh samples are required. Cite this article:Bone Joint Res. 2020;9(5):202–210


Bone & Joint Research
Vol. 9, Issue 8 | Pages 450 - 456
1 Aug 2020
Zhang Z Cai Y Bai G Zhang C Li W Yang B Zhang W

Aims. This study aimed to evaluate calprotectin in synovial fluid for diagnosing chronic prosthetic joint infection (PJI) . Methods. A total of 63 patients who were suspected of PJI were enrolled. The synovial fluid calprotectin was tested by an enzyme-linked immunosorbent assay (ELISA). Laboratory test data, such as ESR, CRP, synovial fluid white blood cells (SF-WBCs), and synovial fluid polymorphonuclear cells (SF-PMNs), were documented. Chi-squared tests were used to compare the sensitivity and specificity of calprotectin and laboratory tests. The area under the curve (AUC) of the receiver operating characteristic (ROC) curve was calculated to determine diagnostic efficacy. Results. The median calprotectin level was 776 ÎŒg/ml (interquartile range (IQR) 536.5 to 1132) in the PJI group and 54.5 ÎŒg/ml (IQR, 38.75 to 78.25) in the aseptic failure (AF) group (p < 0.05). Using a threshold of 173 ug/ml, the sensitivity was 95.2%, with a 97.6% specificity, and the AUC was 0.993. The sensitivity of calprotectin of the antibiotic-treated PJI group was 100% versus 90.9% of the non-antibiotic-treated PJI group. Although 47.6% (ten cases) of the patients in the PJI group received antibiotics before aspiration, the diagnostic efficacy of calprotectin was not affected. The sensitivity and specificity of ESR, CRP, SF-WBCs, and SF-PMNs ranged from 76.2% to 90.5% and 64.3% to 85.7%, respectively. Conclusion. Calprotectin in synovial fluid has great diagnostic efficacy for PJI diagnosisand outperformed ESR, CRP, SF-WBCs, and SF-PMNs. Cite this article: Bone Joint Res 2020;9(8):450–456


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_10 | Pages 7 - 7
1 Oct 2022
Bottagisio M Viganò M Zagra L Pellegrini A De Vecchi E
Full Access

Aim. The analysis of synovial fluid has proved to be of crucial importance in the diagnostic process of prosthetic joint infections (PJI), suggesting the presence of an infection before the microbiological culture results. In this context, several studies illustrated the efficacy of synovial calprotectin in supporting the diagnosis of PJI [1, 2]. However, several testing methods have been explored to detect synovial calprotectin levels, emphasizing the need to use a standardized, rapid and rapid test. In this study, synovial calprotectin was analyzed by means of a commercial stool test [3] to explore whether the detected levels might predict PJIs and, therefore, being a promising tool for the fast and reliable diagnosis of this complication. Method. The synovial fluid of 55 patients underwent to revision of the prosthetic implant were analyzed. The measurement of calprotectin was carried out by of commercial stool test, following the protocol for liquid samples. Calprotectin levels were then compared to other synovial biomarkers of PJI such as leucocyte esterase and count and percentage of polymorphonuclear cells. Data analysis were performed using R software v4.1.1 (R Core Team) and package “pROC” [4]. Receiver operator characteristics curves were designed using culture test as gold standard to evaluate the area under curve (AUC) of each method (with DeLong method for confidence-interval calculation). Thresholds were calculated to maximize Youden's index; sensitivity and specificity were reported. One-to-one Pearson's correlations coefficient were calculated for each pair of methods. P value <0.05 were considered statistically significant. Results. Of the 55 synovial fluids analyzed, 13 patients were diagnosed with PJI and 42 with an aseptic failure of the implant. The specificity, sensitivity, and AUC of calprotectin resulted 0.90, 0.85, and 0.86 (95%CI: 0.72–0.99), respectively with a set threshold of 226.5 µg/g. The values of calprotectin had a moderate and statistically relevant correlation with the synovial leucocyte counts (r. s. = 0.54, p = 0.0003) and the percentage of polymorphonuclear cells (r. s. = 0.68, p = 0.0000). Conclusions. From this analysis, it can be concluded that synovial calprotectin is a valuable biomarker that correlates with other established indicator of local infection, delivering a rapid and reliable results and supporting the diagnostic process of PJI


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_17 | Pages 66 - 66
24 Nov 2023
d'Epenoux Louise R Robert M Caillon H Crenn V Dejoie T Lecomte R Tessier E Corvec S Bemer P
Full Access

Background. The diagnosis of periprosthetic joint infection (PJI) remains a challenge in clinical practice and the analysis of synovial fluid (SF) is a useful diagnostic tool. Recently, two synovial biomarkers (leukocyte esterase (LE) strip test, alpha-defensin (AD)) have been introduced into the MSIS (MusculoSkeletal Infection Society) algorithm for the diagnosis of PJI. AD, although promising with high sensitivity and specificity, remains expensive. Calprotectin is another protein released upon activation of articular neutrophils. The determination of calprotectin and joint CRP is feasible in a routine laboratory practice with low cost. Purpose. Our objective was to evaluate different synovial biomarkers (calprotectin, LE, CRP) for the diagnosis of PJI. Methods. In this monocentric study, we collected SF from hip, knee, ankle and shoulder joints of 42 patients who underwent revision or puncture for diagnostic purposes. Exclusion criteria included a joint surgery in the previous 3 months and a diagnosis of a systemic inflammatory disease. PJI was diagnosed in a multidisciplinary consultation meeting (RCP) of the Reference Centers for Osteoarticular Infections of the Great West (CRIOGO). SF was analysed for LE, CRP and calprotectin. The cut-off values used were 50 mg/L for calprotectin, 8.8 mg/L for CRP and 125 WBC/µL for LE. The overall sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were calculated for these different synovial markers. Results. Of the 42 patients included, 28 were considered as infected and 14 uninfected. The statistical parameters are presented in Table 1. Conclusion. The present study shows that the synovial calprotectin assay has an excellent sensitivity and a 100% NPV for the diagnosis of PJI, suggesting that a result < 50 mg/L could exclude PJI. This promising study suggests that calprotectin should be included with synovial CRP in a new decision algorithm for the diagnosis of PJI. For any tables or figures, please contact the authors directly


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 20 - 20
23 Jun 2023
Macheras G Papadakis S Argyrou C Kateros K
Full Access

Pre-operative definitive diagnosis of infection in painful total hip arthroplasty (THA) is not always easy to be established, making the intra-operative decision-making process crucial in management of revision hip surgery. Calprotectin is a promising point-of-care novel biomarker that has displayed high accuracy in detecting PJIs. From November 2020 to December 2022, 105 patients with painful primary THA were treated with revision THA in 3 orthopaedic departments. Pre-operatively, 23 were considered infected and treated with two-stage revision THA. The remaining 82 were likely infected according to the 2019 EBJIS criteria. The suspicion of low-grade infection was based on clinical (rest and/or night pain), laboratory (CRP, ESR, WBC – normal or slightly elevated) and radiological evaluation (loosening). Hip aspiration under CT imaging was performed in these cases and 34 of them yielded positive culture and were treated with two-stage revision. Aspiration was ineffective in the remaining 48 cases (33 negative, 15 unsuccessful attempts). Intra-operatively, calprotectin was measured with lateral flow immunoassay test in these patients. Cases with calprotectin levels ≥ 50 mg/L were treated with 2-stage revision THA; otherwise, they were considered not-infected and one-stage revision was performed. Synovial fluid and tissue samples were collected for analysis. Implants were sent for sonication fluid cultures. Calprotectin was positive (≥ 50 mg/L) in 27 cases and negative in 21 cases. There was 1 false negative case with positive tissue cultures. Out of the 27 positive cases, 25 had positive tissue cultures and sonication. However, 2 cases with high calprotectin levels (>200 mg/L) were not infected. The false positive result was attributed to severe metallosis. Calprotectin sensitivity was 96.2%, specificity 90.9%, PPV 92.6%, NPV 95.2%, AUC 0.935. The results of this ongoing study indicate that calprotectin seems to be a valuable tool in facilitating the intra-operative decision-making process in cases that low-grade infection is suspected and diagnosis cannot be established pre-operatively


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_17 | Pages 67 - 67
24 Nov 2023
Gardete-Hartmann S Simon S Frank BJ Sebastian S Loew M Sommer I Hofstaetter J
Full Access

Aim. Synovial calprotectin point-of-care test (POC) has shown promising clinical value in diagnosing periprosthetic joint infections (PJIs). However, limited data are available in unclear cases. Moreover, cut-off values for calprotectin lateral flow assay (LFA) and enzyme-linked immunosorbent assay (ELISA) need to be adapted. The aim of this study was to evaluate the performance of an upgraded and more sensitive version of a synovial calprotectin LFA along with ELISA immunoassay in patients with septic, aseptic, and unclear cases. Methods. Overall, 206 prospectively collected periprosthetic synovial fluid samples from 169 patients (106f/63m; 38 hip/131 knee) who underwent revision surgeries were retrospectively evaluated for calprotectin concentration. The following groups were analyzed: unexpected negative cultures (UNC; 32/206), unexpected positive cultures (UPC; 28/206), and unclear cases (65/206) with conflicting clinical results. In addition, we added a true aseptic (40/206), and true septic (41/206) control groups according to the international consensus meeting (ICM) 2018 PJI classification. Calprotectin concentration was determined by a rapid quantitative LFA (n=206) (Lyfstone®, Norway), and compared to calprotectin ELISA immunoassay (171/206). For the determination of a new calprotectin cut-off value, analysis of the area under the curve (AUC) followed by Youden's J statistic were performed using the calproctectin values from clear septic and aseptic cases. Sensitivity and specificity for calprotectin were calculated. All statistical analyses were performed using IBM-SPSS® version 25 (Armonk, NY, USA). Results. An absolute calprotectin value of 43 mg/ml, and 40.15 mg/ml was determined to be the optimal cut-off for PJI diagnosis using the new version of the LFA and ELISA, respectively. With this cut-off, the sensitivity and specificity of synovial calprotectin concentration for PJI were 88.1% (95% CI 77.8 to 94.7) and 76.6% (95% CI 61.9 to 87.7) for LFA, and 97.06% (95% CI 89.8 to 99.64) and 93.6% (95% CI 82.5 to 98.66) for ELISA, respectively. Of the evaluated groups, UNC 30/32 (93.8%) vs 26/27 (96.3%), UPC 6/28 (21.4%) vs 4/21 (19%), and unclear samples 45/65 (69.2%) vs 30/56 (53.6%) displayed a high likelihood of infection by using LFA, and ELISA, respectively. Conclusion. The upgraded version of the calprotectin quantitative LFA with a new suggested cut-off for infected samples showed additional clinical value in identifying cases at high risk of infection in unclear PJI revisions. Additionally, calprotectin ELISA immunoassay had a better performance than LFA. Further large sample-size validation studies are warranted


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_15 | Pages 18 - 18
1 Dec 2021
Warren J Anis H Bowers K Villa J Pannu T Klika AK Piuzzi N Colon-Franco J Higuera-Rueda C
Full Access

Aim. Several options to standardize the definition of periprosthetic joint infection (PJI) have been created including the 2013 Musculoskeletal Infection Society (MSIS), 2018 Intentional Consensus Meeting (ICM), and the 2019 proposed European Bone and Joint Infection Society (EBJIS) criteria. Synovial fluid biomarkers have been investigated in an effort to simplify and improve the diagnosis of PJI. The aim of this study was to test the sensitivity, specificity, positive, and negative predicted values (PPV and NPV, respectively) of a calprotectin point of care (POC) test for diagnosing PJI in revision total knee arthroplasty (TKA) patients comparing different sets of criteria (2013 MSIS, 2018 ICM, and 2019 EBJIS criteria) used to define patients as with or without infection. Method. From October 2018 to January 2020 and under IRB approval 123 intraoperative samples of synovial fluid were prospectively collected at two academic hospitals in the same institution from revision TKA patients. All patients underwent standard clinical and laboratory evaluation for PJI at our institution, allowing for categorization using the 3 criteria. Patients were adjudicated by 2 blinded and independent reviewers for the 3 sets of criteria. The 3 criteria agreed 91.8% of the time. Four likely cases by the 2019 proposed EBJIS were considered unlikely and 1 inconclusive case by the 2018 ICM was considered not infected for the purposes of analysis. Calprotectin POC testing followed manufacturer's instructions using a threshold of >50 mg/L to indicate PJI. Sensitivities, specificities, PPV, NPV, and areas under the curve (AUC) were calculated for the 3 sets of criteria. Results. Using 2013 MSIS criteria the calprotectin POC test demonstrated a sensitivity, specificity, PPV, NPV AUC of 98.1%, 95.7%, 94.5%, 98.5%, and 0.969, respectively. Using 2018 ICM the POC test demonstrated a sensitivity, specificity, PPV, NPV and (AUC) of 98.2%, 98.5%, 98.2%, 98.5%, and 0.984, respectively. Using the 2019 proposed EBJIS criteria the POC test demonstrated a sensitivity, specificity, PPV, NPV and area under the curve (AUC) of 93.2%, 100.0%, 100.0%, 94.2%, and 0.966, respectively. Conclusions. The calprotectin lateral flow POC test has an excellent sensitivity and specificity regardless of the set of criteria used to define PJI. These results are promising and suggest that the calprotectin lateral flow test may be used as a rule out test in a cost-conscious health care model or when conventional diagnostic tools may not be available. Further investigations of the calprotectin PCO test must be completed to validate these results


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_15 | Pages 39 - 39
1 Dec 2021
Suren C Lazic I Stephan M von Eisenhart-Rothe R Prodinger PM
Full Access

Aim. The diagnosis of prosthetic joint infection (PJI) is challenging and relies on a combination of parameters. However, the currently recommended diagnostic algorithms have not been validated for patients with recent surgery, dislocation or other events associated with a local inflammatory response. As a result, these algorithms are not safely applicable offhand in such conditions. Calprotectin is a leukocyte protein that has been shown to be a reliable biomarker of PJI. The purpose of this study was to evaluate the use of calprotectin to rule out PJI within 3 months after surgery or dislocation. Method. We included patients who underwent arthroplasty revision surgery at our institution within 3 months after any event causing inflammation. Calprotectin was measured using a lateral-flow assay. European Bone and Joint Infection Society (EBJIS) criteria were used as gold standard. The diagnostic accuracy of calprotectin was calculated. Results. Twenty-two patients (14 females, 8 males) with a mean age of 65.1 ± 12.3 years with 13 total hip (THA) and 9 total knee arthroplasties (TKA) were included. There were 4 instances of possible early-onset acute infection, 4 dislocations, 2 patella tendon ruptures, 1 local tissue reaction to the sutures, 4 cases of early loosening, 2 component breakages and 1 avulsion of a polyethylene patella button. Using the EBJIS criteria, PJI was confirmed postoperatively in 12 cases. With a cut-off at 50mg/L, the calprotectin lateral flow test was positive in 10 cases. This results in a sensitivity of the calprotectin test of 0.75, a specificity of 0.9, positive and negative predictive values of 0.9 and 0.75, respectively, and a positive and negative likelihood ratio of 7.5 and 0.28, respectively. Conclusions. Aggravating the difficulties of ruling out PJI prior to revision surgery, local inflammation can be caused by some conditions in which the widely accepted PJI definition criteria cannot be applied. Nevertheless, an accurate diagnosis of PJI is just as crucial in these situations as it is in planned revision surgery. This study suggests that calprotectin is a promising diagnostic parameter for ruling out PJI in such cases. The calprotectin lateral-flow assay is readily applicable at the beginning of the procedure, yielding results that can assist in the decision whether to perform septic revision or aseptic partial or component exchange within 15 minutes, and with an overall accuracy of 81.8%


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_23 | Pages 22 - 22
1 Dec 2016
Wouthuyzen-Bakker M Ploegmakers J Kampinga G Jutte P Kobold AM
Full Access

Introduction. In the last couple of years, several synovial biomarkers have been introduced in the diagnostic algorithm for a prosthetic joint infection (PJI). Alpha defensin-1 proved to be one of the most promising, with a high sensitivity and specificity. However, a major disadvantage of this biomarker is the high costs. Calprotectin is a protein that is present in the cytoplasm of neutrophils, and is released upon neutrophil activation. Its value has been established for decades as a (fecal) marker for inflammatory bowel disease. Aim. To determine the efficacy of synovial calprotectin in the diagnosis of a prosthetic joint infection. Methods. We prospectively collected synovial fluid (from hip, knee and shoulder) from patients with a proven PJI (n=15) and from patients that underwent a revision surgery without signs of a PJI (n=19). Patients with an active rheumatoid arthritis and/or gout were excluded from the study. Synovial fluid was centrifuged and the supernatant was used to measure calprotectin, by using a rapid, point of care test. This test was validated for synovial fluid analysis of calprotectin using an ELISA. A Mann-Whitney U test was used to calculate the difference between both patient groups. Results. The median calprotectin level was 899 mg/L (range 28–2120) for PJI versus 22 mg/L (range 0–202) for controls (p < 0.0001). With a cut-off value of 50 mg/L, synovial calprotectin has a high sensitivity of 93%, and a specificity of 84%. The positive and negative predictive values are 82% and 94%, respectively. Conclusions. Synovial calprotectin is a potentially valuable biomarker in the diagnosis of a PJI. With a point of care test, a rapid quantative diagnosis can be made within the operating room (results are obtained within 20 minutes), and could help in the decision making process to re-implant a prosthesis in a one stage procedure. In comparison to the currently available test (to measure alpha defensin-1), the measurement of calprotectin test is much cheaper (500 euro versus 20 euro per sample) and easily to implement in hospitals where this test is already available. Its diagnostic efficacy for exclusively low-grade PJI should be further elaborated


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_5 | Pages 1 - 1
1 Mar 2021
Warren J Anis H Klika AK Bowers K Pannu T Villa J Piuzzi N Colon-Franco J Higuera-Rueda C
Full Access

Aim. Despite several synovial fluid biomarkers for diagnosis of periprosthetic joint infection (PJI) have being investigated, point-of-care (POC) tests using these biomarkers are not widely available. Synovial calprotectin has recently been reported to effectively exclude diagnosis of PJI and a novel lateral flow POC test using it has shown potential to be effective. Thus, the aims of this study were to 1) validate calprotectin POC with enzyme linked immunosorbet assay (ELISA) 2) at 2 separate thresholds for PJI diagnosis in total knee arthroplasty (TKA) patients using the 2013 Musculoskeletal Infection Society (MSIS) PJI diagnosis criteria as the gold standard. Method. Intraoperative synovial fluid samples were prospectively collected from 123 patients who underwent revision TKAs (rTKA) at two academic hospitals within the same healthcare system from October 2018 to January 2020. The study was conducted under IRB approval. Included patients followed the hospital standard for their PJI diagnostic work-up. Data collection included demographic, clinical, and laboratory data in compliance with MSIS criteria. Synovial fluid samples were analysed by calprotectin POC and ELISA tests in accordance with manufacturer's instructions. Patients were categorized as septic or aseptic using MSIS criteria by two independent reviewers blinded to calprotectin assay results. The calprotectin POC and ELISA test performance characteristics were calculated with sensitivities, specificities, positive, and negative predicted values (PPV and NPV, respectively) and areas under the curve (AUC) for 2 different PJI diagnosis scenarios: (1) a threshold of >50 mg/L and (2) a threshold of >14 mg/L. Results. According to MSIS criteria, 53 rTKAs were septic while 70 rTKA were aseptic. In the (1) >50 mg/mL threshold scenario, the calprotectin POC and ELISA performance showed 100% agreement with sensitivity, specificity, PPV, NPV, and AUC, respectively, of 98.1%, 95.7%, 94.5%, 98.5%, and 0.969. In the (2) >14 mg/mL threshold scenario, the POC slightly outperformed the ELISA with sensitivity, specificity, PPV, NPV and AUC of 98.1%, 87.1%, 85.2%, 98.4%, and 0.926, respectively (ELISA values were 98.1%, 82.9%, 81.3%, 98.3%, and 0.905, respectively). Conclusions. The calprotectin POC test performed as well as the ELISA at the >50mg/L threshold and was slightly better at the >14 mg/L threshold. The >50 mg/L threshold had a better specificity while maintaining the same sensitivity as the >14 mg/L threshold. This test could be effectively implemented as a rule out test. However, further investigations with larger cohorts are necessary to validate these results


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_17 | Pages 6 - 6
1 Dec 2018
Wouthuyzen-Bakker M Ploegmakers J Ottink K Kampinga G Wagenmakers-Huizenga L Jutte P Kobold AM
Full Access

Aim. Diagnosing or excluding a chronic prosthetic joint infection (PJI) prior to revision surgery can be a clinical challenge. To enhance accuracy of diagnosis, several biomarkers were introduced in recent years, but most are either expensive or not available as a rapid test. We compared the diagnostic accuracy of leucocyte esterase (€0.20 per sample), calprotectin (€20 per sample) and alpha defensin (€200 per sample). Method. We prospectively evaluated PJI patients with chronic pain with or without prosthetic loosening between 2017 and 2018. Synovial fluid was collected prior to revision surgery. Leucocyte esterase was measured using a reagent strip (2+ considered as positive), and calprotectin and alpha defensin were measured using a lateral flow immunoassay. Intraoperative cultures (5 periprosthetic tissue samples, synovial fluid and sonication fluid) incubated for 9 days, were used as gold standard. At least two positive cultures of low-grade microorganisms with the same antibiogram were required to diagnose PJI. Results. A total of 19 patients were included (knee =11, hip =8). None of the patients were treated with antibiotics prior to revision surgery. A PJI was diagnosed in 8 patients (42.1%). The diagnostic accuracy of leucocyte esterase vs. calprotectin vs. alpha defensin was as follows; sensitivity 50.0% vs. 87.5% vs. 87.5%, specificity 81.8% vs. 90.9% vs. 100%, positive predictive value 60.0% vs. 87.5% vs. 100% and negative predictive value 75.0% vs. 90.9% vs. 91.6%, respectively. Both calprotectin and alpha defensin were false negative in one PJI caused by Cutibacterium acnes. The other two C. acnes PJIs were correctly diagnosed with both tests. Conclusions. Calprotectin is as accurate as alpha defensin in excluding a chronic PJI at 10% of the costs. Future studies with a large number of patients are necessary to analyze its diagnostic accuracy in very low-grade infections, in particularly caused by C. acnes


The Bone & Joint Journal
Vol. 103-B, Issue 1 | Pages 46 - 55
1 Jan 2021
Grzelecki D Walczak P Szostek M Grajek A Rak S Kowalczewski J

Aims. Calprotectin (CLP) is produced in neutrophils and monocytes and released into body fluids as a result of inflammation or infection. The aim of this study was to evaluate the utility of blood and synovial CLP in the diagnosis of chronic periprosthetic joint infection (PJI). Methods. Blood and synovial fluid samples were collected prospectively from 195 patients undergoing primary or revision hip and knee arthroplasty. Patients were divided into five groups: 1) primary total hip and knee arthroplasty performed due to idiopathic osteoarthritis (OA; n = 60); 2) revision hip and knee arthroplasty performed due to aseptic failure of the implant (AR-TJR; n = 40); 3) patients with a confirmed diagnosis of chronic PJI awaiting surgery (n = 45); 4) patients who have finished the first stage of the PJI treatment with the use of cemented spacer and were qualified for replantation procedure (SR-TJR; n = 25), and 5) patients with rheumatoid arthritis undergoing primary total hip and knee arthroplasty (RA; n = 25). CLP concentrations were measured quantitatively in the blood and synovial fluid using an immunoturbidimetric assay. Additionally, blood and synovial CRP, blood interleukin-6 (IL-6), and ESR were measured, and a leucocyte esterase (LE) strip test was performed. Results. Patients with PJI had higher CLP concentrations than those undergoing aseptic revision in blood (median PJI 2.14 mg/l (interquartile range (IQR) 1.37 to 3.56) vs AR-TJR 0.66 mg/l (IQR 0.3 to 0.83); p < 0.001) and synovial fluid samples (median PJI 20.46 mg/l (IQR 14.3 to 22.36) vs AR-TJR 0.7 mg/l (IQR 0.41 to 0.95); p < 0.001). With a cut-off value of 1.0 mg/l, blood CLP showed a sensitivity, specificity, positive predictive value, and negative predictive value of 93.3%, 87.5%, 89.4%, and 92.1%, respectively. For synovial fluid with a cut-off value of 1.5 mg/l, these were 95.6%, 95%, 95.5%, and 95%, respectively. Conclusion. This small study suggests that synovial and blood CLP are useful markers in chronic PJI diagnosis with similar or higher sensitivity and specificity than routinely used markers such as CRP, ESR, IL-6, and LE. CLP was not useful to differentiate patients with PJI from those with rheumatoid arthritis. Cite this article: Bone Joint J 2021;103-B(1):46–55


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_17 | Pages 71 - 71
24 Nov 2023
Heesterbeek P Pruijn N Boks S van Bokhoven S Dorrestijn O Schreurs W Telgt D
Full Access

Aim. Diagnosis of periprosthetic shoulder infections (PSI) is difficult as they are mostly caused by low-virulent bacteria and patients do not show typical infection signs, such as elevated blood markers, wound leakage, or red and swollen skin. Ultrasound-guided biopsies for culture may therefore be an alternative for mini-open biopsies as less costly and invasive method. The aim of this study was to determine the diagnostic value and reliability of ultrasound-guided biopsies for cultures alone and in combination polymerase chain reaction (PCR), and/or synovial markers for preoperative diagnosis of PSI in patients undergoing revision shoulder surgery. Method. A prospective explorative diagnostic cohort study was performed including patients undergoing revision shoulder replacement surgery. A shoulder puncture was taken preoperatively before incision to collect synovial fluid for interleukin-6 (IL-6), calprotectin, WBC, polymorphonuclear cells determination. Prior to revision surgery, six ultrasound-guided synovial tissue biopsies were collected for culture and two additional for PCR analysis. Six routine care tissue biopsies were taken during revision surgery and served as reference standard. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV; primary outcome measure), and accuracy were calculated for ultrasound-guided biopsies, and synovial markers, and combinations of these. Results. Fifty-five patients were included. In 24 patients, routine tissue cultures were positive for infection. Cultures from ultrasound-guided biopsies diagnosed an infection in 7 of these patients, yielding a sensitivity, specificity, PPV, NPV, and accuracy of 29.2%, 93.5%, 77.8%, 63.0%, and 65.6%, respectively. Ultrasound-guided biopsies in combination with synovial WBC increased the NPV to 76.7% and accuracy to 73.8%. When synovial WBC and calprotectin were combined with ultrasound-guided biopsies, it resulted in a better diagnostic value: sensitivity 69.2%, specificity 80.0%, PPV 69.2%, NPV 80.0%, and accuracy 75.8%. Ultrasound-guided biopsies in combination with calprotectin and ESR yielded a sensitivity of 50.0%, specificity of 93.8%, PPV of 80.0%, NPV of 78.9%, and accuracy of 79.2%. Synovial fluid was obtained in 42 patients. Sensitivities of WBC, PMN, IL-6, and calprotectin were between 25.0% and 35.7%, specificities between 89.5% and 95.0%, PPVs between 60.0% and 83.3%, NPVs between 65.4% and 69.4%, and accuracies between 64.5% and 70.6%. Conclusions. In this prospective study we showed that ultrasound-guided biopsies for cultures alone and in combination with PCR and/or synovial markers are not reliable enough to use in clinical practice for the preoperative diagnosis of low grade PSI


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_17 | Pages 65 - 65
24 Nov 2023
Schindler M Walter N Sigmund IK Maderbacher G Alt V Rupp M
Full Access

Background. The identification of novel biomarker which is highly specific and sensitive for periprosthetic joint (PJI) have the potential to improve diagnostic accuracy and ultimately improve patient outcomes. Thus, the aim of this systemic review is to identify and evaluate novel biomarkers for the preoperative diagnostics of PJI. Methods. MEDLINE, EMBASE, PubMed and Cochrane Library databases identified from 1. st. of January 2018 to 30. th. of September. 2022. We used “periprosthetic joint infection” OR “prosthetic joint infection” OR “periprosthetic infection” as the diagnosis of interest and the target index applied AND “marker”. To focus on novel biomarkers already used biomarkers of the established PJI diagnostic criteria of MSIS, ICM and EBJIS were not included in the analysis. These three criteria were considered the reference standard during quality assessment. Results. A total of 19 studies were included. In these, fourteen different novel biomarkers were analyzed. Fifteen studies (79%) had prospective designs and the other four (22%) were retrospective studies. Six studies (33%) included only periprosthetic knee infections and thirteen (67%) included periprosthetic knee and hip infections. Proteins were analyzed in most cases (nine studies), followed by molecules (three studies), exosome (two studies) as well as DNA (two studies), interleukin (one study) and lysosome (one study). One novel and promising marker that had been frequently analyzed is calprotectin. Conclusion. No marker demonstrated higher sensitivity and specificity than already known parameters used for standardized treatment based on established PJI definitions. Further studies are needed to elucidate the benefit and usefulness of implementing new biomarkers in diagnostic PJI settings


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_10 | Pages 90 - 90
1 Oct 2022
Jensen LK Jensen HE Gottlieb H
Full Access

Aim. To describe the histopathology of the first and last debrided bone tissue in chronic osteomyelitis and answer the following research question; is the last debrided bone tissue viable and without signs of inflammation?. Method. In total, 15 patients with chronic osteomyelitis were allocated to surgical treatment using a one stage protocol including extensive debridement. Suspected infected bone tissue eradicated early in the debridement procedure was collected as a clearly infected sample (S1). Likewise, the last eradicated bone tissue was collected as a suspected non-infected sample (S2), representing the status of the bone void. In all cases, the surgeon debrided the bone until visual confirmation of healthy bleeding bone. The samples were processed for histology, i.e. decalcification and paraffin embedding, followed by cutting and staining with Haematoxylin and Eosin. Immunohistochemistry with MAC-387 antibodies towards the calprotectin of neutrophil granulocytes (NGs) was also performed and used for estimation of a neutrophil granulocyte (NG) score (0, 1, 2 or 3), by the method described for fracture related infections (1). Results. For the S1 samples the median NG score was 3 which is considered confirmatory for infection. However, following debridement the median NG score was significantly (p = 0.032) reduced to 2. Often NGs were seen as single cells, but in seven S1 samples and in one S2 sample massive NG accumulations were observed. The S1 samples showed a mix of granulation tissue, fibrosis, viable bone, and bone necrosis. The S2 samples contained viable bone tissue and occasionally (10/15) small fragments of necrotic bone or bone debris were seen. Furthermore, a large number of erythrocytes were observed in most S2 samples. Conclusions. The present study shows that the inflammatory response still existents after debridement, although the response fades from the center of infection. Therefore, sampling of debrided bone tissue for histology must be performed initially during surgery, to avoid underestimation of the inflammatory response, i.e. the NG score. The last debrided bone tissue cannot by definition be considered completely viable and caution should be made to remove blood (rinse) before intraoperative evaluation of the viability of debrided cancellous bone. Remnant necrotic bone fragments or debris could represent low-vascular hiding places for leftover bacteria. Application of local antibiotics might have a central role in clearing of these small non-viable bone pieces at the bone void interface


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_8 | Pages 30 - 30
1 Apr 2017
Islam N Whitehouse M Mehandale S Blom A Bannister G Ceredig R Bradley B
Full Access

Background. Post-traumatic immunosuppression (PTI) after surgery increases vulnerability to nosocomial infections, sepsis, and death. Knee arthroplasty offers a sterile clinical model to characterise PTI and explore its underlying mechanisms. Methods. This prospective non-randomised cohort study of primary total knee arthroplasty was approved by the Local Ethics Committee. Exclusion criteria included revision-arthroplasty, pre-existing infections, blood-transfusions, malignancy, and auto-immune disease. 48 recruited patients fell into two groups, the first received unwashed anti-coagulated autologous salvaged blood transfusions after surgery (ASBT cohort, n=25). The second received no salvaged blood transfusions (NSBT cohort, n=18). Venous blood was sampled pre-operatively and within 3–7 days post-operatively. Salvaged blood was sampled at one and six hours post-operatively. Biomarkers of immune status included: interleukins (IL) or cytokines (x15), chemokines (x3), Damage-Associated-Molecular-Patterns (DAMPS) (x5), anti-microbial proteins (x3), CD24, and Sialic-acid-binding-Immunoglobulin-type-Lectin-10 (Siglec-10). Results were expressed as fold-change over pre-operative values. Only significant changes are described. Results. Certain biomarkers associated with sterile trauma were common to all 43 patients, including supra-normal: IL-6, IL-1-Receptor-Antagonist, IL-8, Heat-Shock-Protein-70 (HSP70), Calprotectin, CD24 and Siglec-10. But, whereas in NSBT patients post-operative pro-inflammatory biomarkers were sub-normal consistent with PTI, they were supra-normal in ASBT patients implying its reversal. These PTI-biomarkers included: IL-1β, IL-2, IL-17A, Interferon-gamma (IFN-γ), Tumour-Necrosis-Factor-alpha (TNF-α), and Annexin-A2. Reversal of PTI by salvaged blood was further endorsed in ASBT by sub-normal levels of the anti-inflammatory biomarkers: IL-4, IL-5, IL-10, and IL-13. Salvaged blood analyses revealed sustained supra-normal levels of DAMPs, CD24 and Siglec-10; and increasingly elevated levels of cytokines and chemokines during the six hour collection period. Interestingly, plasma CD24, Siglec-10, HSP70 and Calprotectin levels were significantly correlated, implying physical association within the circulation. Conclusions. Several anti-inflammatory processes triggered by traumatised tissue induce systemic PTI, thereby increasing vulnerability to infections. Reversal of PTI by re-infusion of anti-coagulated salvaged blood suggests a novel source of immuno-stimulants


The Bone & Joint Journal
Vol. 104-B, Issue 11 | Pages 1193 - 1195
1 Nov 2022
Rajput V Meek RMD Haddad FS

Periprosthetic joint infection (PJI) remains an extremely challenging complication. We have focused on this issue more over the last decade than previously, but there are still many unanswered questions. We now have a workable definition that everyone should align to, but we need to continue to focus on identifying the organisms involved. Surgical strategies are evolving and care is becoming more patient-centred. There are some good studies under way. There are, however, still numerous problems to resolve, and the challenge of PJI remains a major one for the orthopaedic community. This annotation provides some up-to-date thoughts about where we are, and the way forward. There is still scope for plenty of research in this area.

Cite this article: Bone Joint J 2022;104-B(11):1193–1195.


Bone & Joint Research
Vol. 12, Issue 2 | Pages 113 - 120
1 Feb 2023
Cai Y Liang J Chen X Zhang G Jing Z Zhang R Lv L Zhang W Dang X

Aims

This study aimed to explore the diagnostic value of synovial fluid neutrophil extracellular traps (SF-NETs) in periprosthetic joint infection (PJI) diagnosis, and compare it with that of microbial culture, serum ESR and CRP, synovial white blood cell (WBC) count, and polymorphonuclear neutrophil percentage (PMN%).

Methods

In a single health centre, patients with suspected PJI were enrolled from January 2013 to December 2021. The inclusion criteria were: 1) patients who were suspected to have PJI; 2) patients with complete medical records; and 3) patients from whom sufficient synovial fluid was obtained for microbial culture and NET test. Patients who received revision surgeries due to aseptic failure (AF) were selected as controls. Synovial fluid was collected for microbial culture and SF-WBC, SF-PNM%, and SF-NET detection. The receiver operating characteristic curve (ROC) of synovial NET, WBC, PMN%, and area under the curve (AUC) were obtained; the diagnostic efficacies of these diagnostic indexes were calculated and compared.


Bone & Joint Research
Vol. 12, Issue 9 | Pages 559 - 570
14 Sep 2023
Wang Y Li G Ji B Xu B Zhang X Maimaitiyiming A Cao L

Aims

To investigate the optimal thresholds and diagnostic efficacy of commonly used serological and synovial fluid detection indexes for diagnosing periprosthetic joint infection (PJI) in patients who have rheumatoid arthritis (RA).

Methods

The data from 348 patients who had RA or osteoarthritis (OA) and had previously undergone a total knee (TKA) and/or a total hip arthroplasty (THA) (including RA-PJI: 60 cases, RA-non-PJI: 80 cases; OA-PJI: 104 cases, OA-non-PJI: 104 cases) were retrospectively analyzed. A receiver operating characteristic curve was used to determine the optimal thresholds of the CRP, ESR, synovial fluid white blood cell count (WBC), and polymorphonuclear neutrophil percentage (PMN%) for diagnosing RA-PJI and OA-PJI. The diagnostic efficacy was evaluated by comparing the area under the curve (AUC) of each index and applying the results of the combined index diagnostic test.


Bone & Joint Research
Vol. 11, Issue 6 | Pages 398 - 408
22 Jun 2022
Xu T Zeng Y Yang X Liu G Lv T Yang H Jiang F Chen Y

Aims

We aimed to evaluate the utility of 68Ga-citrate positron emission tomography (PET)/CT in the differentiation of periprosthetic joint infection (PJI) and aseptic loosening (AL), and compare it with 99mTc-methylene bisphosphonates (99mTc-MDP) bone scan.

Methods

We studied 39 patients with suspected PJI or AL. These patients underwent 68Ga-citrate PET/CT, 99mTc-MDP three-phase bone scan and single-photon emission CT (SPECT)/CT. PET/CT was performed at ten minutes and 60 minutes after injection, respectively. Images were evaluated by three nuclear medicine doctors based on: 1) visual analysis of the three methods based on tracer uptake model, and PET images attenuation-corrected with CT and those not attenuation-corrected with CT were analyzed, respectively; and 2) semi-quantitative analysis of PET/CT: maximum standardized uptake value (SUVmax) of lesions, SUVmax of the lesion/SUVmean of the normal bone, and SUVmax of the lesion/SUVmean of the normal muscle. The final diagnosis was based on the clinical and intraoperative findings, and histopathological and microbiological examinations.


The Bone & Joint Journal
Vol. 103-B, Issue 12 | Pages 1745 - 1753
1 Dec 2021
Walinga AB Stornebrink T Langerhuizen DWG Struijs PAA Kerkhoffs GMMJ Janssen SJ

Aims

This study aimed to answer two questions: what are the best diagnostic methods for diagnosing bacterial arthritis of a native joint?; and what are the most commonly used definitions for bacterial arthritis of a native joint?

Methods

We performed a search of PubMed, Embase, and Cochrane libraries for relevant studies published between January 1980 and April 2020. Of 3,209 identified studies, we included 27 after full screening. Sensitivity, specificity, area under the curve, and Youden index of diagnostic tests were extracted from included studies. We grouped test characteristics per diagnostic modality. We extracted the definitions used to establish a definitive diagnosis of bacterial arthritis of a native joint per study.


The Bone & Joint Journal
Vol. 103-B, Issue 1 | Pages 18 - 25
1 Jan 2021
McNally M Sousa R Wouthuyzen-Bakker M Chen AF Soriano A Vogely HC Clauss M Higuera CA Trebše R

Aims

The diagnosis of periprosthetic joint infection (PJI) can be difficult. All current diagnostic tests have problems with accuracy and interpretation of results. Many new tests have been proposed, but there is no consensus on the place of many of these in the diagnostic pathway. Previous attempts to develop a definition of PJI have not been universally accepted and there remains no reference standard definition.

Methods

This paper reports the outcome of a project developed by the European Bone and Joint Infection Society (EBJIS), and supported by the Musculoskeletal Infection Society (MSIS) and the European Society of Clinical Microbiology and Infectious Diseases (ESCMID) Study Group for Implant-Associated Infections (ESGIAI). It comprised a comprehensive review of the literature, open discussion with Society members and conference delegates, and an expert panel assessment of the results to produce the final guidance.


Bone & Joint 360
Vol. 9, Issue 6 | Pages 5 - 11
1 Dec 2020
Sharma V Turmezei T Wain J McNamara I


The Bone & Joint Journal
Vol. 100-B, Issue 10 | Pages 1345 - 1351
1 Oct 2018
Kuo F Lu Y Wu C You H Lee G Lee MS

Aims

The aim of this study was to compare the results of 16S/28S rRNA sequencing with the erythrocyte sedimentation rate (ESR), C-reactive protein (CRP) level, and synovial fluid analysis in the diagnosis of prosthetic joint infection (PJI).

Patients and Methods

Between September 2015 and August 2016, 214 consecutive patients were enrolled. In the study population, there were 25 patients with a PJI and 189 controls. Of the PJI patients, 14 (56%) were women, and the mean age at the time of diagnosis was 65 years (38 to 83). The ESR and CRP levels were measured, and synovial fluid specimens were collected prospectively. Synovial fluid was subjected to reverse transcription polymerase chain reaction (RT-PCR)/sequence analysis targeting the 16S/28S rRNA, and to conventional culture. Laboratory personnel who were blind to the clinical information performed all tests. The diagnosis of PJI was based on the criteria of the Musculoskeletal Infection Society.


The Bone & Joint Journal
Vol. 100-B, Issue 6 | Pages 749 - 754
1 Jun 2018
Partridge DG Winnard C Townsend R Cooper R Stockley I

Aims

The aim of this study was to establish the diagnostic accuracy of culture of joint aspirate with and without saline injection-reaspiration.

Patients and Methods

This is a retrospective analysis of 580 hip and knee aspirations in patients who were deemed to have a moderate to high risk of infection, and who subsequently proceeded to revision arthroplasty over a period of 12 years. It was carried out at a large quaternary referral centre where preoperative aspiration is routine.