header advert
Results 1 - 12 of 12
Results per page:
Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 13 - 13
1 Sep 2012
Glennie RA Giles JW Athwal GS Johnson JA Faber KJ
Full Access

Purpose

Glenoid component loosening is a common reason for failed total shoulder arthroplasty. Multiple factors have been suggested as causes for component loosening that may be related to cement technique. The purpose of the study was to compare the load transfer across a polyethylene glenoid bone construct with two different cementing techniques.

Method

Eight cadaveric specimens underwent polyethylene glenoid component implantation. Four had cement around the pegs only (CPEG) and four had cement across the entire back (CBACK) of the implant including around the pegs. Step loading was performed with a pneumatic actuator and a non-conforming humeral head construct capable of applying loads at various angles. Strain gauges were placed at the superior and inferior poles of the glenoid and position trackers were applied to the superior and inferior aspects polyethylene component. Micro CT data were obtained before and after the loading protocol.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 150 - 150
1 Sep 2012
Giles JW Elkinson I Boons HW Ferreira LM Litchfield R Johnson JA Athwal GS
Full Access

Purpose

The management of moderate to large engaging Hill-Sachs lesions is controversial and surgical options include remplissage, allograft reconstruction, and partial resurfacing arthroplasty. Few in-vitro studies have quantified their biomechanical characteristics and none have made direct comparisons. The purpose of this study was to compare joint stability and range of motion (ROM) among these procedures using an in-vitro shoulder simulator. It was hypothesized that all procedures would prevent defect engagement, but allograft and partial resurfacing would most accurately restore intact biomechanics; while remplissage would provide the greatest stabilization, possibly at the expense of motion.

Method

Eight cadaveric shoulders were tested on an active in-vitro shoulder simulator. Each specimen underwent testing in 11 conditions: intact, Bankart lesion, Bankart repair, and two unrepaired Hill-Sachs lesions (30% & 45%) which were then treated with each of the three techniques. Anterior joint stability, ROM in extension and internal-external rotation, and glenohumeral engagement were assessed. Stability was quantified as resistance, in N/mm, to an anteriorly applied load of 70N.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 84 - 84
1 Sep 2012
Lapner P Bell K Sabri E Rakhra K Athwal GS
Full Access

Purpose

Controversy exists regarding the optimal technique of subscapularis mobilization during shoulder arthroplasty. The purpose of this multicentre randomized double-blind study was to compare the functional outcomes and healing rates of the lesser tuberosity osteotomy (LTO) to the subscapularis tenotomy (ST).

Method

Patients undergoing shoulder arthroplasty were randomized to receive either a LTO or ST. The primary outcome was to compare subscapularis strength, as measured by an electronic hand-held dynamometer at 12 months. Secondary outcomes included range of motion, WOOS, Constant and ASES scores. A sample size calculation determined that 80 patients provided 80% power with a 50% effect size to detect a significant difference between groups.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 85 - 85
1 Sep 2012
Alolabi B Gray A Ferreira LM Johnson JA Athwal GS King GJ
Full Access

Purpose

The coronoid and collateral ligaments are key elbow stabilizers. When repair of comminuted coronoid fractures is not possible, prosthetic replacement may restore elbow stability. A coronoid prosthesis has been designed with an extended tip in an effort to augment elbow stability in the setting of residual collateral ligament insufficiency. The purpose of this biomechanical study, therefore, was to compare an anatomic coronoid replacement with an extended tip implant both with and without ligament insufficiency.

Method

Two coronoid prostheses were designed and developed based on CT-derived images adjusted for cartilage thickness: an anatomical implant and an extended-tip implant. Passive elbow extension was performed in 7 cadaveric arms in the varus and valgus positions. Varus-valgus laxity of the ulna relative to the humerus was quantified with a tracking system with an intact coronoid, a 40% coronoid deficiency, an anatomical prosthesis, and an extended prosthesis, with the collateral ligaments sectioned and repaired.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 153 - 153
1 Sep 2012
Faber KJ Pike JM Grewal R Athwal GS King GJ
Full Access

Purpose

Limited information is available regarding the functional outcomes of radial head fractures managed with open reduction and internal fixation (ORIF). The purpose of this study was to determine the functional outcomes of radial head fractures treated with ORIF.

Method

Fifty-two patients, with a mean age of 4412 years, who were treated with radial head ORIF were evaluated at a mean of 4.42.4 years. Thirty were isolated radial head fractures (Group A), 13 (Group B) were associated with a complex fracture-dislocation (terrible triad variants), and 5 (Group C) were associated with a proximal ulnar fracture (Monteggia/trans-olecranon variants). Fourty-four were partial articular fractures and 8 were complete articular fractures. Outcomes were assessed with physical and radiographic examination, and validated self-reported questionnaires.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 155 - 155
1 Sep 2012
Elkinson I Giles JW Faber KJ Boons HW Ferreira LM Johnson JA Athwal GS
Full Access

Purpose

The remplissage procedure may be performed as an adjunct to Bankart repair to address an engaging Hill-Sachs defect. Clinically, it has been reported that the remplissage procedure improves joint stability but that it may also restrict shoulder range of motion. The purpose of this biomechanical study was to examine the effects of the remplissage procedure on shoulder motion and stability. We hypothesized that the remplissage procedure would improve stability and prevent engagement but may have a deleterious effect on motion.

Method

Eight cadaveric forequarters were mounted on a custom biomechanical testing apparatus which applied simulated loads independently to the rotator cuff muscles and to the anterior, middle and posterior deltoid. The testing conditions included: intact shoulder, Bankart defect, Bankart repair, 2 Hill-Sachs defects (15%, 30%) with and without remplissage. Joint range of motion and translation were recorded with an optical tracking system. Outcomes measured were internal-external rotation range of motion in adduction and 90 combined abduction, extension range of motion and stability, quantified in terms of joint stiffness and engagement, in abduction.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 18 - 18
1 Sep 2012
Elkinson I Giles JW Faber KJ Boons HW Ferreira LM Johnson JA Athwal GS
Full Access

Purpose

The remplissage technique of insetting the infraspinatus tendon and posterior joint capsule into an engaging Hill-Sachs lesion has gained in popularity. However, a standardized technique for suture anchor and suture placement has not been defined for this novel procedure. The purpose of this biomechanical study was to compare three remplissage techniques by evaluating their effects on joint stiffness and motion.

Method

Cadaveric forequarters (n=7) were mounted on a custom active biomechanical shoulder simulator. Three randomly ordered techniques were conducted: T1- anchors in the valley of the defect, T2- anchors in the rim of the humeral head; T3- anchors in the valley with medial suture placement. The testing conditions included: intact, Bankart, Bankart repair, and 15% & 30% HS lesions with repairs (T1, T2, T3). Outcome measures including internal-external range of motion and stability were recorded. Stability was quantified in terms of glenohumeral joint stiffness against an externally applied anterior force of 70N.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 86 - 86
1 Sep 2012
Athwal GS Rouleau DM MacDermid JC King GJ
Full Access

Purpose

Radial head implant over-lengthening, a common cause of capitellar wear and clinical failure, is difficult to diagnose using radiographs of the injured elbow. The purpose of this study was to determine if a novel measurement technique based on contralateral elbow radiographs, termed the RACER method, could be used to accurately estimate the magnitude of radial head implant over-lengthening. Part I of this study examined the side-to-side consistency of radiographic landmarks used in the measurement technique. Part II of this study validated the technique using simulated radial head implant over-lengthening in a cadaveric model.

Method

Part I: A side-to-side comparison of elbow joint dimensions was performed in 50 patients (100 radiographs). Part II: Radial head prostheses of varying lengths (0,+2mm,+4mm,+6mm,+8mm) were implanted in 4 paired cadaveric specimens (8 elbows). Radiographs were obtained and measurements were performed by 2 examiners blinded to implant size to determine if contralateral radiographs could diagnose and provide a valid estimate of the magnitude of implant over-lengthening. Intra and inter-rater reliability was determined.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 87 - 87
1 Sep 2012
Alolabi B Studer A Gray A Ferreira LM King GJ Athwal GS
Full Access

Purpose

There have been a number of described techniques for sizing the diameter of radial head implants. All of these techniques, however, are dependent on measurements of the excised native radial head. When accurate sizing is not possible due to extensive comminution or due to a previous radial head excision, it has been postulated that the proximal radioulnar joint (PRUJ) may be used as an intraoperative landmark for correct sizing. The purpose of this study was to: 1) determine if the PRUJ could be used as a reliable landmark for radial head implant diameter sizing when the native radial head in unavailable, and (2) determine the reliability of measurements of the excised radial head.

Method

Twenty-seven fresh-frozen denuded ulnae and their corresponding radial heads (18 males, 9 females) were examined. The maximum diameter (MaxD), minimum diameter (MinD) and dish diameter (DD) of the radial heads were measured twice, 3–5 weeks apart, using digital calipers. Two fellowship-trained upper extremity surgeons, an upper extremity fellow and a senior orthopedic resident were then asked to independently select a radial head implant diameter based on the congruency of the radius of curvature of the PRUJ to that of the radial head trial implants. The examiners were blinded to the native radial head dimensions. This selection was repeated 3–5 weeks later by two of the investigators. Correlation between radial head measurements and radial head implant diameter sizes was assessed using Pearsons correlation coefficient (PCC) and inter and intra-observer reliability were assessed using intra-class correlation coefficient (ICC).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 171 - 171
1 Sep 2012
Armitage MS Elkinson I Giles JW Athwal GS
Full Access

Purpose

Coracoid transfer is an effective reconstructive procedure for complex glenohumeral joint instability. Recently, the congruent-arc Latarjet procedure has been described which orients the coracoid graft undersurface flush to the glenoid articular margin. The purported advantage of this modification is that the radii of curvature of the coracoid undersurface and the anterior glenoid rim are believed to be similar, and therefore, congruent. The purpose of this study was to determine the dimensions of the coracoid and to compare the radius of curvature (ROC) of the coracoid undersurface to the ROC of the intact glenoid and various glenoid bone-loss scenarios.

Method

Thirty-four CT-based 3D models of the shoulder were examined using commercially available software. The mean dimensions of the coracoid were determined and the ROC was calculated for the coracoid undersurface, the intact glenoid as well as 20%, 35% and 50% anterior glenoid bone-loss scenarios. Intra and inter-rater statistics were calculated.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 172 - 172
1 Sep 2012
Rafehi S Athwal GS Lalone EA Johnson M King GJ
Full Access

Purpose

Current coronoid fracture classification systems are based on fragment size and configuration using plain radiographs and/or CT. During surgery, coronoid fracture fragments appear much larger than anticipated because cartilage is radiolucent and therefore not taken into account with preoperative imaging. The purpose of this study was to quantify the articular cartilage thickness of the coronoid process, with reference to coronoid fracture classifications.

Method

Twenty-four cadaveric ulnae were dissected, imaged, and analyzed using the OsiriX software program (3.6–64 bit, Geneva). Thirteen identifiable landmarks were chosen on the coronoid, olecranon and proximal radioulnar joint to measure articular cartilage thickness. Intra-observer and inter-observer reliability were calculated.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 82 - 82
1 Sep 2012
Gray A Alolabi B Ferreira LM Athwal GS King GJ Johnson JA
Full Access

Purpose

The coronoid process is an integral component for elbow stability. In the setting of a comminuted coronoid fracture, where repair is not possible, a prosthetic device may be beneficial in restoring elbow stability. The hypothesis of this in-vitro biomechanical study was that an anatomic coronoid prosthesis would restore stability to the coronoid deficient elbow.

Method

A metal coronoid prosthesis was designed and developed based on CT-derived images adjusted for cartilage thickness. The kinematics and stability of eight fresh-frozen male cadaveric arms (mean age 77.4 years, range 69–92 years) were quantified in the intact state; after collateral ligament sectioning and repair (control state); after a simulated 40% transverse coronoid fracture; and after implantation of a coronoid prosthesis. Elbow flexion was simulated passively with the arm oriented in the varus position and the forearm in pronation. Varus-valgus angulation (VV) and internal-external rotation (IE) of the ulna relative to the humerus were quantified with an electromagnetic tracking system (Flock of Birds, Ascension Technologies, Burlington, VT, static accuracy: 1.8mm position, 0.5 orientation).