Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_5 | Pages 61 - 61
1 Mar 2017
Lancaster-Jones OO Al-Hajjar M Williams S Jennings L Thompson J Isaac G Fisher J
Full Access

Introduction and Aims

There are many variables that can affect the occurrence and severity of edge loading in hip replacement. A translational mismatch between the centres of rotation of the head and cup may lead to dynamic separation, causing edge loading and increased wear. Combining a steep inclination angle with such translational mismatch in the medial-lateral axis caused a larger magnitude of separation and increased severity of edge loading. Previous studies have shown variation in the hip Swing Phase Load (SPL) during gait between different patients. The aim of this study was to apply a translational mismatch and determine the effect of varying the SPL on the occurrence and severity of edge loading under different cup inclination angles in a hip joint simulator.

Methods

The Leeds II hip joint simulator with a standard gait cycle and 36mm diameter ceramic-on-ceramic bearings (BIOLOX® delta) were used in this study. The study was in two stages; [1] a biomechanical study where the magnitude of dynamic separation, the duration of edge loading and the magnitude of force under edge loading (severity) were assessed under variations in component positioning and SPLs. [2] A wear study to assess edge loading with selected input conditions. For the biomechanical study, a combination of four mismatches, three cup inclination angles, and eight SPLs (Table 1) were investigated. For the wear study, three SPL conditions were selected with one cup angle and one mismatch (Table 1). Three million cycles were completed under each condition. Mean wear rates and 95% confidence limits were determined and statistical analysis (one way ANOVA) completed (significance taken at p<0.05).

Table 1: Study matrix


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 21 - 21
1 Feb 2017
Hua X Wilcox R Fisher J Jones A
Full Access

INTRODUCTION

Mal-positioning of the acetabular component in total hip replacement (THR) could lead to edge loading, accelerated component wear, impingement and dislocation [1,2]. In order to achieve a successful position for the acetabular component, the assessment of the acetabular orientation with reference to different coordinate systems is important [3]. The aims of the present study were to establish a pelvic coordinate system and a global body coordinate system, and to assess the acetabular orientations of natural hips with reference to the two coordinate systems.

METHODS

Three-dimensional (3D) computed tomographic (CT) images of 56 subjects (28 males and 28 females) lying supine were obtained from a public image archive (Cancer Image Archive, website: www.cancerimagingarchive.net). 3D solid models of pelvis and spine were generated from the CT images. Two coordinate systems, pelvic and global body coordinate systems, were established. The pelvic coordinate system was established based on four bony landmarks on the pelvis: the bilateral anterior superior iliac spines (RASIS and LASIS) and the bilateral pubic tubercles (RPT and LPT). The global body coordinate system was generated based on the bony landmarks on the spine: the geometric centers of five lumbar vertebrae bodies and the most dorsal points of five corresponding spinous processes, as well as the anterior sacral promontory (Fig 1a and 1b). The acetabular rim plane was obtained by fitting a set of point along the acetabular rim to a plane using least squares method. The acetabular orientation was defined as the three coordinate components (x-, y- and z- components) of the unit normal vector of the acetabular rim plane in the two coordinate systems (Fig. 1c).


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 146 - 146
1 Feb 2017
McEntire B Jones E Bock R Ray D Bal B Pezzotti G
Full Access

Introduction

Periprosthetic infections are leading causes of revision surgery resulting in significant increased patient comorbidities and costs. Considerable research has targeted development of biomaterials that may eliminate implant-related infections.1 This in vitro study was developed to compare biofilm formation on three materials used in spinal fusion surgery – silicon nitride, PEEK, and titanium – using one gram-positive and one gram-negative bacterial species.

Materials and Methods

Several surface treated silicon nitride (Si3N4, MC2®, Amedica Corporation, Salt Lake City, UT), poly-ether-ether-ketone (PEEK, ASTM D6262), and medical grade titanium (Ti6Al4V, ASTM F136) discs Ø12.7 × 1mm were prepared or acquired for use in this well-plate study. Each group of discs (n=3) were ultrasonically cleaned, UV-sterilized, inoculated with 105Staphylococcus epidermidis (ATCC® 25922™) or Escherichia coli (ATCC® 14990™) and placed in a culture medium of phosphate buffered saline (PBS) containing 7% glucose and 10% human plasma on a shaking incubator at 37°C and 120 rpm for 24 or 48 hrs. Coupons were retrieved, rinsed in PBS to remove planktonic bacteria, placed in a centrifuge with fresh PBS, and vortexed. The bacterial solutions were serially diluted, plated, and incubated at 37°C for 24 to 48 hrs. Colony forming units (CFU/mm2) were counted using applicable dilution factors and surface areas. A two-tailed, heteroscedastic Student's t-test (95% confidence) was used to determine statistical significance.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 31 - 31
1 Feb 2017
Jahani F Fisher J Barton D Brooks J Wilcox R Jones A
Full Access

Introduction

The performance of total hip replacement (THR) devices can be affected by the quality of the tissues surrounding the joint or the mismatch of the component centres during hip replacement surgery. Experimental studies have shown that these factors can cause the separation of the two components during walking cycle (dynamic separation) and the contact of the femoral head with the rim of the acetabular liner (edge loading), which can lead to increased wear and shortened implant lifespan1. There is a need for flexible pre-clinical testing tools which allow THR devices to be assessed under these adverse conditions. In this work, a novel dynamic finite element model was developed that is able to generate dynamic separation as it occurs during the gait cycle. In addition, the ability to interrogate contact mechanics and material strain under separation conditions provides a unique means of assessing the severity of edge loading. This study demonstrates these model capabilities for a range of simulated surgical translational mismatch values, for ceramic-on-polyethylene implants.

Methodology

The components of the THR were aligned and constrained as illustrated in Figure 1. CAD models of commercially available implant geometries were used (DePuy Synthes, Leeds, UK) modified for model simplicity by removing anti-rotation features.

The polyethylene cup liner was given elastic-plastic behaviour. An axial load following the Paul cycle pattern (5 repetitive cycles) with maximum of 3KN and swing phase load of 0.3KN, was applied through the cup holder. The effect of translational mismatch was implemented by using a spring element connected to the cup unit on the lateral side. The spring was compressed by a fixed amount to replicate a degree of medial-lateral mismatch of the components. The instantaneous resultant force vector dictated the dynamic sliding behaviour of the cup against the head. In this study, translational medial-lateral mismatch values of 1, 2, 3 and 4mm were used and the medial-lateral dynamic separation, contact pressure maps and plastic strain were recorded.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_3 | Pages 143 - 143
1 Feb 2017
Greene A Hamilton M Polakovic S Andrews R Jones R Parsons I Saadi P Cheung E Flurin P Wright T
Full Access

INTRODUCTION

As computer navigated surgery continues to progress to the forefront of orthopedic care, the application of a navigated total shoulder arthroplasty has yet to appear. However, the accuracy of these systems is debated, as well as the dilemma of placing an accurate tool in an inaccurate hand. Often times a system's accuracy is claimed or validated based on postoperative imaging, but the true positioning is difficult to verify. In this study, a navigation system was used to preoperatively plan, guide, and implant surrogate shoulder glenoid implants and fiducials in nine cadaveric shoulders. A novel method to validate the position of these implants and accuracy of the system was performed using pre and post operative high resolution CT scans, in conjunction with barium sulfate impregnated PEEK surrogate implants.

METHODS

Nine cadaveric shoulders were CT scanned with .5mm slice thickness, and the digital models were incorporated into a preoperative planning software. Five orthopedic shoulder specialists used this software to virtually place aTSA and rTSA glenoid components in two cadavers each (one cadaver was omitted due to incomplete implantation), positioning the components as they best deemed fit. Using a navigation system, each surgeon registered the native cadaveric bone to each respective CT. Each surgeon then used the navigation system to guide him or her through the total shoulder replacement, and implant the barium sulfate impregnated PEEK surrogate implants. Four cylindrical PEEK fiducials were also implanted in each scapula to help triangulate the position of the surrogate implants. Previous efforts were attempted with stainless steel alloy fiducials, but position and image accuracy were limited by CT artifact. BaSO4 PEEK provided the highest resolution on a postoperative CT with as little artifact as possible. All PEEK fiducials and surrogate implants were registered by probing points and planes with the navigation system to capture the digital position. A high resolution post operative CT scan of each specimen was obtained, and variance between the executed surgical plan and PEEK fiducials was calculated.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_3 | Pages 22 - 22
1 Feb 2017
Huixiang W Newman S Jones G Sugand K Cobb J Auvinet E
Full Access

Introduction

Because of the low cost and easy access, surgical video has become a popular method of acquiring surgical skills outside operating rooms without disrupting normal surgical flow. However, currently existing video systems all use a single point of view (POV). Some complex orthopedic procedures, such as joint replacement, require a level of accuracy in several dimensions. So single and fixed POV video may not be enough to provide all the necessary information for educational and training purposes. The aim of our project was to develop a novel multiple POV video system and evaluate its efficacy as an aid for learning joint replacement procedure compared with traditional method.

Materials and Methods

Based on the videos of a hip resurfacing procedure performed by an expert orthopedic surgeon captured by 8 cameras fixed all around the operating table, we developed a novel multiple POV video system which enables users to autonomously switch between optimal viewpoints (Figure 1). 30 student doctors (undergraduate years 3–5 and naive to hip resurfacing procedure) were recruited and randomly allocated to 2 groups: experiment group and control group, and were assigned to learn the procedure using multiple or single POV video systems respectively. Before learning they were first asked to complete a multiple choicetest designed using a modified Delphi technique with the advice and feedback sought from 4 experienced orthopedic surgeons to test the participants' baseline knowledge of hip resurfacing procedure. After video learning, they were asked to answer the test again to verify their gained information and comprehension of the procedure, followed by a 5-point Likert-scale questionnaire to demonstrate their self-perception of confidence and satisfaction with the learning experience. The scores in the 2 tests and in the Likert-scale questionnaire were compared between 2 groups using Independent-Samples t-test (for normally distributed data) or Mann-Whitney U test (for non-normally distributed data). Statistical significance was set as p<0.05.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_3 | Pages 104 - 104
1 Feb 2017
Noble P Dua R Jones H Garrett K
Full Access

Background

Recent advances in materials and manufacturing processes for arthroplasty have allowed fabrication of intricate implant surfaces to facilitate bony attachment. However, refinement and evaluation of these new design strategies is hindered by the cost and complications of animal studies, particularly during early iterations in development process. To address this problem, we have constructed and validated an ex-vivo bone bioreactor culture system to enable empirical testing of candidate structures and materials. In this study, we investigated mineralization of a titanium wire mesh scaffold under both static and dynamic culturing using our ex vivo bioreactor system.

Methods

Cancellous cylindrical bone cores were harvested from bovine metatarsals and divided into five groups under different conditions. After incubation for 4 & 7 weeks, the viability of each bone sample was evaluated using Live-Dead assay and microscopic anatomy of cells were determined using histology stain H&E. Matrix deposits on the scaffolds were examined with scanning electron microscopy (SEM) while its chemical composition was measured using energy-dispersive x–ray spectroscopy (EDX).


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 36 - 36
1 Feb 2017
Jones H Gonzalez J Doherty D Noble P
Full Access

Introduction

As the population continues to grow and age, the incidence of revision total knee replacement (RTKR) is expected to rise significantly. Modularity within revision total knee systems is common, and recognition of modular junctions as an important source adverse local tissue reaction (ALTR) has not yet been fully described in the literature. In both hips and knees, ALTR may be caused by wear debris from articulating surfaces, stress shielding, and other classic areas of focus, but now attention is shifting towards the role of corrosion products from modular junctions. In severe cases, junctions can become welded together creating significant hurdles in revisions and potentially altered biomechanics in vivo. In view of these issues, the present study was undertaken: (i) to examine the level of damage observed in modular junctions of total knee prostheses obtained at revision, (ii) to correlate the severity of surface damage to the design and composition of the mating components, and (iii) to associate patient demographics and comorbidities with the spectrum of corrosion and fretting seen in retrieved implants.

Methods

117 TKR components from 76 patients were examined after retrieval from revision procedures performed at a single institution. Patient demographics and clinical data were compiled. The retrievals consisted of 57 femoral components and 60 tibial components from a diverse range of manufacturers. The implants were disassembled manually, or in a mechanical testing machine if cold welded, and separated into groups based on mating material type. Modular junctions were then examined using stereomicroscopy (Wild) at magnifications of X6 to X31. Upon inspection, damage on the male component was graded using modified Goldberg scales for corrosion and fretting (Table 1). Factors associated with trunnions having damage scores of 3 or higher were evaluated using standard statistical procedures to determine the susceptibility for corrosion of each junction type and location.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 37 - 37
1 Feb 2017
Jones H Chun A Kim R Gonzalez J Noble P
Full Access

Introduction

Corrosion products from modular taper junctions of hip prostheses have been implicated in adverse local tissue reactions after THR. Numerous factors have been proposed as the root causes of this phenomenon, including implant design and materials, manufacturing variables, intraoperative assembly, and patient lifestyle. As significant taper damage only occurs in a few percent of cases of THR, we have addressed this complication using a “forensic” examination of retrieval specimens to gain insight into the factors initiating the cascade leading to irreversible damage of the modular interface. In this study we report the categorization of over 380 retrievals into groups having shared damage patterns, metallic composition, and interface surface geometries to isolate the genesis of mechanically-assisted corrosion and its relation to intraoperative assembly, manufacturing, and postoperative loading.

Methods

A total of 384 femoral components were examined after retrieval at revision THR. The implants were produced by a diverse range of manufacturers, 271 in CoCr, and 113 in TiAlV, with both smooth (253) and machined (131) tapers. Initially, the implants were sorted into groups based on composition and taper roughness. Each trunnion was then cleaned to remove organic deposits and examined by stereomicroscopy at X6-X31. After an initial pilot study, we developed a classification system consisting of 8 basic patterns of damage (Table 1). We then classified all 384 trunnions according to this 8-group system. The prevalence of each pattern was calculated on the basis of both composition and surface texture of the trunnion.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_22 | Pages 85 - 85
1 Dec 2016
Jones R
Full Access

Obtaining primary wound healing in total joint arthroplasty (TJA) is essential to a good result. Wound healing disturbances (WHD) can occur and the consequences can be devastating to the patient and to the surgeon. Determination of the host healing capacity can be useful in predicting complications. Cierney and Mader classified patients as Type A: no healing compromises and Type B: systemic or local healing compromise factors present. Local factors include traumatic arthritis with multiple previous incisions, extensive scarring, lymphodema, poor vascular perfusion, and excessive local adipose deposition. Systemic compromising factors include diabetes, rheumatic diseases, renal or liver disease, immunocompromise, steroids, smoking, and poor nutrition. Low serum albumin, total lymphocyte count, and low transferrin increase WHD. In high risk situations the surgeon should encourage positive patient choices such as smoking cessation and nutritional supplementation to modify healing responses. Use of tourniquet in obese patients also increases WHD.

Careful planning of incisions, particularly in patients with scarring or multiple previous operations, is productive. Around the knee the vascular viability is better in the medial flap. Thusly, use the most lateral previous incision, do minimal undermining, and handle tissue meticulously. We do all potentially complicated TKA's without tourniquet to enhance blood flow and tissue viability. The use of perioperative anticoagulation will increase wound problems.

If wound drainage or healing problems do occur, immediate action is required. Deep sepsis can be ruled out with a joint aspiration and cell count (less than 2500), differential (less than 60% polys), and negative culture and sensitivity. All hematomas should be evacuated and necrosis or dehiscence should be managed by debridement to obtain a live wound.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_22 | Pages 98 - 98
1 Dec 2016
Jones R
Full Access

The major benefit of TKA with tourniquet is operating in a bloodless field. A possible secondary benefit is a better cement-bone interface for fixation.

The disadvantages of tourniquet use for TKA include multiple risk factors both local and systemic: Nerve damage, Altered hemodynamics with limb exsanguinations (15–20% increase in circulatory volume) and reactive hyperemia with tourniquet release (10% increase in limb size increasing soft tissue tension and secondary pain), Delay in recovery of muscle function, Increased risk of DVT with direct trauma to vessel walls and increased levels of thrombin-antithrombin complexes, A 5.3x greater risk for large venous emboli propagation and transesophageal echogenic particles, Vascular injury with higher risk in atherosclerotic, calcified arteries, Increase in wound healing disturbances, Obese patients TKA with tourniquet show impaired endothelial function and more DVTs.

Our initial experience with TKA without tourniquet was in high risk patients with previous DVT or PE, multiple scarring, or compromised cardiovascular status. We have used this method on all patients for the last 14 years. The protocol includes regional anesthesia, incision and approach made with 90-degree knee flexion, meticulous hemostasis, jet lavage and filtered carbon dioxide delivered to dry and prepare bone beds for cementation, application of topical tranexamic acid and routine closure. We have encountered no differences in blood loss or transfusion rates, cement penetration/ fixation, less postoperative pain, faster straight leg raise and knee flexion gains, and fewer wound healing disturbances. We recommend TKA sans tourniquet. Let it bleed!


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_17 | Pages 33 - 33
1 Nov 2016
Jones R
Full Access

In the USA, 34.9% of adults are currently obese (BMI > 30). Growth in total knee arthroplasty (TKA) is outpacing growth in total hip arthroplasty (THA) largely due to a differential utilization of TKA in overweight patients in the USA. In a recent study, 54.5% of patients reporting to arthroplasty clinics in the USA were obese. From 2006–2010, 61.2% of primary unilateral TKA patients in the USA ACS-NSQIP database were obese. Arthroplasty surgeons are directly affected by the obesity epidemic and need to understand how to safely offer a range of peri-operative care for these patients in order to insure good clinical outcomes.

Pre-operative care for the obese patient involves nutritional counseling, weight loss methods, consideration for bariatric surgery, physical therapy, metabolic workup, and diagnosis and management of frequent comorbid conditions (OSA, DM2, HTN, HLD). Obese patients must also be counseled on their increased risk of complications following TKA.

In the operating room, several steps can be taken to insure success when performing TKA on obese patients. We recommend performing TKA without the use of a tourniquet in order to prevent fat necrosis and increased pain. The incision is made in 90 degrees of knee flexion, atypically midline proximally and curved distally to the midpoint between the tubercle and the medial edge of the tibia. Care is used to minimise the creation of dead space, and the approach to the knee is an extensile medial parapatellar incision. Closure is in multiple layers. The use of negative pressure dressing following surgery can minimise the early wound drainage that is frequently seen after TKA in obese patients.

Post-operative care of the obese patient following TKA involves several unique considerations. Chronic pain and obesity are frequent comorbid conditions and post-operative pain control regimens need to be tailored. Although the physical therapy regimen does not differ in obese patients, obese patients are more likely to be discharged to a rehabilitation facility.

Obese patients have a higher rate of all complications compared to healthy weight. All infection and deep infection increased in obese patients in large meta-analysis. Patients with BMI > 35 are 6.7 times more likely to develop infection after TKA. Patients with BMI > 40 have a 3.35 times higher rate of revision for deep infection than those with BMI < 35. The odds ratio for major complications increases dramatically beyond BMI > 45.

Although there are a few studies that have demonstrated worse clinical outcome in obese patients following TKA, most studies show no difference in clinical outcomes at short- or long-term follow-up. The arthroplasty surgeon must optimise the obese patient prior to surgery, use intra-operative techniques to maximise success, and anticipate potential problems in the post-operative course in order to achieve success with TKA in obese patients.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_17 | Pages 42 - 42
1 Nov 2016
Jones R
Full Access

Functional restoration of patella kinematics is an essential component of TKA, whether the patella is replaced or not. This goal is accomplished by a multifactorial approach: establish proper component position and alignment, especially rotation, avoid IR of the femoral and ER of the tibial components, maintain correct joint line position, achieve symmetrical soft tissue balance

Most modern TKA designs have an anatomic trochlear groove shape to enable midline tracking. Patella implants are better designed as well with three equilateral lugs for fixation and either dome or anatomic shape. The apex of the patella component should be aligned with the apex of the patella raphe which is more medial than lateral. This method leaves an island of exposed lateral patella facet which is managed with the “lateral slat technique” to be described. It is essentially an intraosseous lateral release. The early mobilization of modern TKA patients demands watertight closure to prevent soft tissue attenuation and late tracking issues.

When confronted with a patient with a laterally dislocated patella, implementation of the “lateral slat technique” should be done at the approach to obtain midline tracking. Such patients require a median parapatellar (MPP) approach and may need distal-lateral vastus medialis advancement (Insall procedure).

Adherence to the principles iterated herein will produce a happy patient with good patello-femoral kinematics and function.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_17 | Pages 63 - 63
1 Nov 2016
Jones R
Full Access

Persistent post-surgical pain (PPSP) remains a problem after knee replacement with some studies reporting up to 20% incidence. Pain is usually felt by those who do not operate to be a monolithic entity. All orthopaedic surgeons know that this is not the case. At its most basic level, pain can be divided into two categories, mechanical and non-mechanical.

Mechanical pain is like the pain of a fresh fracture. If the patient does not move, the pain is less. This type of pain is relieved by opiates. Mechanical pain is seen following knee replacement, but is becoming less frequent. It is caused by a combination of malrotations and maltranslations, often minor, which on their own would not produce problems. The combination of them, however, may produce a knee in which there is overload of the extensor mechanism or of the medial stabilizing structures. If these minor mechanical problems can be identified, then corrective surgery will help.

Non-mechanical pain is present on a constant basis. It is not significantly worsened by activities. Opiates may make the patient feel better, but they do not change the essential nature of the pain. Non-mechanical pain falls into three broad groups, infection, neuropathic and perceived pain. Infection pain is usually relieved by opiates. Since some of this pain is probably due to pressure, its inclusion in the non-mechanical pain group is questionable, but it is better left there so that the surgeon always considers it. Low grade chronic infection can be extremely difficult to diagnose. Loosening of noncemented knee components is so rare that when it is noted radiologically, infection should be very high on the list of suspicions. The name neuropathic pain suggests that we know much more about it than we do in reality. Causalgia or CRPS-type two is rare following knee replacement. CRPS-type one or reflex sympathetic dystrophy probably does exist, but it is probably over-diagnosed. The optimum treatment I have found is lumbar sympathetic blocks. Lyrica, Gabapentin and Cymbalta may also help. Perceived pain is the largest group. It does not matter what you tell the patient, some believe a new knee should be like a new car, i.e. you step into it and drive away. The fact that they have to work to make it work is horrifying. Perceived pain is widespread. The classic treatise, Dr. Ian McNabb's book “Backache”, should be studied by all who wish to understand pain complaints.

Any experienced knee surgeon will have his list of red flags or caveats. I will list only a few. If the patient comes in with a form asking for a disability pension on the first visit. If the patient's mother answers the questions. If the patient comes in taking massive doses of opiates. If the patient is referred to you by a surgeon who does more knee replacements than you do.

There are other issues such as good old fibromyalgia, which appears to have gone the way of the dodo. It has been replaced by something equally silly called central sensitization. The theory of central sensitization is that if one has pain somewhere or other for three months or six months or whatever, there are going to be changes in the brain and spinal cord. It then does not matter what happens to the original pain, i.e. whether or not it goes away, the pain will persist because of the changes in the brain, hence, the title of the pain in the brain syndrome. If this theory was correct, we might as well all go home because we have all been wasting our time for the last 30 years because none of our patients would get any better. After all, all of our patients have had pain for a lot longer than three months, many of them have been involved in trauma and sometimes, compensation is at issue. The pain in the brain theory, therefore, sounds about as realistic as the flat earth society or the treatment of Galileo.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_20 | Pages 100 - 100
1 Nov 2016
Petis S Vasarhelyi E Lanting B Jones I Birmingham T Howard J
Full Access

Total hip arthroplasty (THA) is the most effective treatment modality for severe arthritis of the hip. Patients report excellent clinical and functional outcomes following THA, including subjective improvement in gait mechanics. However, few studies in the literature have outlined the impact of surgical approach on gait kinetics and kinematics. The purpose of this study was to determine the impact of surgical approach for THA on quantitative gait analysis.

Thirty patients undergoing THA for primary osteoarthritis of the hip were assigned to one of three surgical approaches (10 anterior, 10 posterior, and 10 lateral). A single surgeon performed each individual approach. Each patient received standardised implants at the time of surgery (cementless stem and acetabular component, cobalt chrome femoral head, highly cross-linked liner). Patients underwent 3D gait analysis pre-operatively, and at 6- and 12-weeks following the procedure. At each time point, temporal gait parameters, kinetics, and kinematics were compared. Statistical analysis was performed using one-way analysis of variance.

All three groups were similar with respect to age (p=0.27), body mass index (p=0.16), and the Charlson Comorbidity Index (p=0.66). Temporal parameters including step length, stride length, gait velocity, and percent stance and swing phase were similar between the groups at all time points. The lateral cohort had higher pelvic tilt during stance on the affected leg than the anterior cohort at 6-weeks (p=0.033). Affected leg ipsilateral trunk lean during stance was higher in the lateral group at 6-weeks (p=0.006) and 12-weeks (p=0.037) compared to the other cohorts. The anterior and posterior groups demonstrated an increased external rotation moment at 6-weeks (p=0.001) and 12-weeks (p=0.005) compared to the lateral group.

Although temporal parameters were similar across all groups, some differences in gait kinematics and kinetics exist following THA using different surgical approaches. However, the clinical relevance based on the small magnitude of the differences remains in question.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_14 | Pages 16 - 16
1 Jul 2016
Aujla R Patel S Aziz S Jones A Bhatia M
Full Access

Acute Achilles tendon (AT) rupture management remains debatable but non-operative functional regimes are beginning to dominate current treatment algorithms. The aim of this study was to identify predictors of functional outcome in patients with AT ruptures treated non-operatively with an immediate weight bearing functional regime in an orthosis.

Analysis of prospectively gathered data from a local database of all patients treated non-operativelyat our institution with anAT rupture was performed. Inclusion criteria required a completed Achilles Tendon Rupture Score (ATRS) at a minimum of 8 months post rupture. The ATRS score was correlated against age, gender, time following rupture, duration of treatment in a functional orthoses (8- and 11-week regimes) and complications. 236 patients of average age 49.5 years were included.

The mean ATRS on completion of rehabilitation was 74 points. The mean ATRS was significantly lower in the 37 females as compared to the 199 males, 65.8 vs 75.6 (p = 0.013). Age inversely affected ATRS with a Pearsons correlation of −0.2. There was no significant difference in the ATRS score when comparing the two different treatment regime durations. There were 12 episodes of VTE and 4 episodes of re-rupture. The ATRS does not change significantly after 8 months of rupture.

Patients with AT ruptures treated non-operatively with a functional rehabilitation regime demonstrate good function with low re-rupture rates. Increasing age and female gender demonstrate inferior functional outcomes.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_14 | Pages 7 - 7
1 Jul 2016
Lokikere N Saraogi A Sonar U Porter M Kay P Wynn-Jones H Shah N
Full Access

Distal femoral replacement is an operation long considered as salvage operation for neoplastic conditions. Outcomes of this procedure for difficult knee revisions with bone loss of distal femur have been sparsely reported.

We present the early results of complex revision knee arthroplasty using distal femoral replacement implant, performed for severe osteolysis and bone loss.

Retrospective review of clinic and radiological results of 25 consecutive patients operated at single centre between January 2010 and December 2014. All patients had single type of implant. All data was collected till the latest follow up. Re-revision for any reason was considered as primary end point.

Mean age at surgery was 72.2 years (range 51 – 85 years). Average number of previous knee replacements was 2.28 (range 1 to 6). Most common indications were infection, aseptic loosening and peri-prosthetic fracture. Average follow up was 24.5 months (range: 3–63 months). 1 patient died 8 months post-op due to unrelated reasons. Re-revision rate was 2/25 (8%) during this period. One was re-revised for aseptic loosening and one was revised for peri-prosthetic fracture of femur. Two other peri-prosthetic fractures were managed by open reduction and internal fixation. All 3 peri-prosthetic fractures occurred with low energy trauma.

It is noteworthy that there was no hinge or mechanical failures of the implant. Peri-prosthetic fracture in 12% of patients in this series is of concern. There are no similar studies to compare this data with. The length of the stem, type of fixation of the stem, weight of the distal femoral component of implant can be postulated as factors contributing to risk of peri-prosthetic fracture.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_13 | Pages 3 - 3
1 Jun 2016
Lokikere N Jakaraddi C Wynn-Jones H Shah N
Full Access

Primary total hip replacement (THR) in patients with abnormal/altered proximal femoral anatomy/narrow canals presents a technical challenge. There are only limited standard prosthetic stems available to deal with narrow canals or abnormal morphology. Many prefer to use expensive custom implants which often have a lag time to manufacture and do not always have long term published outcomes.

We present results of the Asian C-stem (which is a standard implant available on the shelf) used in patients predominantly of Caucasian origin with abnormal proximal femoral anatomy.

We retrospectively reviewed clinic-radiological results of 131 patients (131 stems) who underwent primary THR using Asian C-stem at Wrightington Hospital till their latest follow up. Revision for any reason was considered as primary end point.

Mean age at surgery was 50.8 years (16 – 80). The 2 commonest indications were primary osteoarthritis (66 patients) and hip dysplasia (54 patients). Mean follow up was 43.5 months with a minimum follow up of 12 months and maximum follow up of 97 months. There were 2 recurrent dislocations and 1 hip subluxed twice. One dislocation needed revision surgery. 1 patient underwent acetabular revision for loosening. There was no stem failure, obvious loosening or loss of fixation in any patients in our series with regards to the Asian C-stem. There were no infections and intra-operative perforations or fractures.

C-stem Asian is a reliable implant for patients undergoing THR with abnormal proximal femoral anatomy or narrow canals. Long term follow up is essential.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 68 - 68
1 May 2016
Jones G Clarke S Jaere M Cobb J
Full Access

The treatment of patients with osteoarthritis of the knee and associated extra-articular deformity of the leg is challenging. Current teaching recognises two possible approaches: (1) a total knee replacement (TKR) with intra-articular bone resections to correct the malalignment or (2) an extra-articular osteotomy to correct the malalignment together with a TKR (either simultaneously or staged).

However, a number of these patients only have unicompartmental knee osteoarthritis and, in the absence of an extra-articular deformity would be ideal candidates for joint preserving surgery such as unicompartmental knee replacement (UKR) given its superior functional outcome and lower cost relative to a TKR [1).

We report four cases of medial unicondylar knee replacement, with a simultaneous extra-articular osteotomy to correct deformity, using novel 3D printed patient-specific guides (Embody, UK) (see Figure 1). The procedure was successful in all four patients, and there were no complications. A mean increase in the Oxford knee score of 9.5, and in the EQ5D VAS of 15 was observed.

To our knowledge this is the first report of combined osteotomy and unicompartmental knee replacement for the treatment of extra-articular deformity and knee osteoarthritis. This technically challenging procedure is made possible by a novel 3D printed patient-specific guide which controls osteotomy position, degree of deformity correction (multi-plane if required), and orientates the saw-cuts for the unicompartmental prosthesis according to the corrected leg alignment.

Using 3D printed surgical guides to perform operations not previously possible represents a paradigm shift in knee surgery. We suggest that this joint preserving approach should be considered the preferred treatment option for suitable patients.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_7 | Pages 90 - 90
1 May 2016
Cobb J Collins R Brevadt M Auvinet E Manning V Jones G
Full Access

Normal human locomotion entails a rather narrow base of support (BoS), of around 12cm at normal walking speeds. This relatively narrow gait requires good balance, and is beneficial, as it minimises the adduction moment at the knee. Normal knees have a slightly oblique joint line, and slight varus, which allow the normal human to walk rapidly with a narrow BoS. Patients with increased varus and secondary osteoarthritis have a broader BoS, which exacerbates the excessive load, making walking painful and ungainly.

We wondered if there would be a difference between the base of support of patients whose knee kinematics had been preserved, by retaining the native jointline obliquity and the acl, in comparison with those whose alignment had been altered to a mechanically correct ‘neutral’ alignment.

Materials and Methods

Of 201 patients measured following knee arthroplasty, 31 unicondylar patients and 35 total knee patients, with a single primary arthroplasty, and no co-morbidities, over 1 year post-operatively were identified. Two control groups of controls, a younger cohort of 112 people and 17 in an age matched older cohort.

All operations were performed by the same surgeon. The total knees were cruciate retaining devices, inserted in mechanical alignment, and the unicondylar knees were inserted retaining the native alignment and joint-line obliquity.

The gait of all subjects was analysed on an instrumented, calibrated treadmill with underlying force plates. Patients start by walking at a comfortable speed for them for 5 minutes, before the speed of the treadmill is increased at 1/2 km/h increments until maximum walking speed obtained, spending 30 seconds at each. After the flat test, it was then repeated on a downhill slope of 6°.

Base of Support is interpreted as the distance between the centre point of heel strike and toe off from one foot to that of the other.

The top walking speed in the unicondylar group was significantly greater than that of the total knee group, as we reported in 2013.

TKA patients have an average BoS of 14cm, while UKA patients and controls have a 12cm BoS. The BoS did not reduce with speed. This 2cm, or 17% increase in BoS is significant. Shapiro-Wilk tests demonstrate a normal distribution to the results, and ANOVA testing reveals a significant difference (p<0.05) within the groups between the speeds of 4.5 to 9. Post-Hoc Bonferroni testing reveal a significant difference between the TKA group and each of the other three groups.

On the downhill test (figure 1), the mean BoS in the TKA group increased to 16cm. This increase is highly significant, with a p value of <0.001, while the increase in the UKA group at higher speeds failed to reach significance, and the controls both stayed at 12cm. 6 Bi-uni knees tested acted just like the UKAs.

Discussion

A narrow base of support minimises excessive loads across the joint line. Maintenance of jointline obliquity and an ACL enables this feature to be returned to normal following uni, or bi-uni, while a well aligned TKA seems to prevent it.