Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_2 | Pages 21 - 21
1 Mar 2021
Pryce G Al-Hajjar M Thompson J Wilcox R Board T Williams S
Full Access

Abstract

Objectives

Impingement of total hip replacements (THRs) can cause rim damage of polyethylene liners, and lead to dislocation and/or mechanical failure of liner locking mechanisms[1]. A geometric model of a THR in situ was previously developed to predict impingement for different component orientations and joint motions of activities[2]. However, the consequence of any predicted impingement is unknown. This study aimed to develop an in-vitromethod to investigate the effects of different impingement scenarios.

Method

A ProSim electro-mechanical single-station hip simulator (Simulation Solutions) was used, and the 32mm diameter metal-on-polyethylene THRs (DePuy Synthes) were assessed. The THR was mounted in an inverted orientation, and the input (motion and loading) applied simulated a patient stooping over to pick an object from the floor[3]. The impingement severity was varied by continuing motion past the point of impingement by 2.5° or 5°, and compressive load applied in the medial-lateral direction was varied from 100N to 200N. Each test condition was applied for 40,000 cycles (n=3). Rim penetration was assessed using a CMM and component separation was measured during the tests.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_6 | Pages 28 - 28
1 May 2019
Pryce G Al-Hajjar M Wilcox R Thompson J Board T Williams S
Full Access

Impingement of total hip replacements (THRs) can cause rim damage of polyethylene liners, and lead to dislocation and/or mechanical failure of liner locking mechanisms[1]. Previous work has focussed on the influence of femoral neck profile on impingement without consideration of neck-shaft angle. This study assessed the occurrence of impingement with two different stem designs (Corail standard [135°] and coxa vara [125°]) under different activities with varying acetabular cup orientation (30° to 70° inclination; 0° to 50° anteversion) using a geometric modelling tool.

The tool was created in a computer aided design software programme, and incorporated an individual's hemi-pelvis and femur geometry[3] with a THR (DePuy Synthes Pinnacle® shell and neutral liner; size 12 Corail® standard or coxa vara and 32mm head). Kinematic data of activities associated with dislocation[2], such as stooping to pick an object from the floor was applied and incidences of impingement were recorded.

Predicted implant impingement was influenced by stem design. The coxa vara stem was predicted to cause implant impingement less frequently across the range of activities and cup orientations investigated, compared to the standard stem [Fig. 1]. The cup orientations predicted to cause impingement the least frequently were at lower inclination and anteversion angles, relative to the standard stem [Fig. 1]. The coxa vara stem included a collar, while the standard stem was collarless; additional analysis indicated that differences were due to neck angle and not the presence of a collar.

This study demonstrated that stem neck-shaft angle is an important variable in prosthetic impingement in THR and surgeons should be aware of this when choosing implants. Future work will consider further implant design and bone geometry variables. This tool has the potential for use in optimising stem design and position and could assist with patient specific stem selection based on an individual's activity profile.

For any figures or tables, please contact the authors directly.


Background

Antibiotic loaded bone cement (ALBC) is commonly used in cemented total hip arthroplasty (THA) in an attempt to reduce the risk of prosthetic joint infection (PJI). However, its role versus plain cement remains controversial due to the potential risk of developing resistant organisms and potential excess costs incurred from its usage. We investigated the relationship of ALBC and plain cement in affecting outcome of revision surgery after primary THA.

Methodology

We conducted a retrospective study of data collected from National Joint Registry for England and Wales, Northern Ireland and the Isle of Man between 1st September 2005 until 31st August 2017. A logistic regression analysis model was used to investigate the association between ALBC versus plain cement and the odds ratio (OR) for revision, adjusting for age, ASA grade, bearing surfaces, head size and cup and stem fixation. Indications for revision recorded in NJR were considered in separate models.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 141 - 141
1 Apr 2019
Pryce G Sabu B Al-Hajjar M Wilcox R Thompson J Board T Williams S
Full Access

Introduction

Impingement of total hip arthroplasties (THAs) has been reported to cause rim damage of polyethylene liners, and in some instances has led to dislocation and/or mechanical failure of liner locking mechanisms in modular designs. Elevated rim liners are used to improve stability and reduce the risk of dislocation, however they restrict the possible range of motion of the joint, and retrieval studies have found impingement related damage on lipped liners.

The aim of this study was to develop a tool for assessing the occurrence of impingement under different activities, and use it to evaluate the effects a lipped liner and position of the lip has on the impingement-free range of motion.

MATERIALS & METHOD

A geometrical model incorporated a hemi-pelvis and femur geometries of one individual with a THA (DePuy Pinnacle® acetabular cup with neutral and lipped liners; size 12 Corail® stem with 32mm diameter head) was created in SOLIDWORKS (Dassault Systèmes). Joint motions were taken from kinematic data of activities of daily living that were associated with dislocation of THA, such as stooping to pick an object off the floor and rolling over. The femoral component was positioned to conform within the geometry of the femur, and the acetabular component was orientated in a clinically acceptable position (45° inclination and 20° anteversion). Variation in orientation of the apex of the lip was investigated by rotating about the acetabular axes from the superior (0°) in increments of 45° (0°−315°), and compared to a neutral liner.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_14 | Pages 39 - 39
1 Nov 2018
Del-Valle-Mojica J Alonso-Rasgado M Jiménez-Cruz D Bailey C Board T
Full Access

In order to reduce the risk of dislocation larger femoral heads in total hip arthroplasty (THA) are being used by surgeons in recent years. The standard head size of 28 mm used in 73% of all hip procedures in 2003 was used in only 29% in 2016; whereas head sizes of 32 mm and 36 mm combined, were used in 70%. The increase of head size effectively reduces the thickness of the acetabular cup, altering the load transfer. Herein, this research work investigates the effect of increasing the femoral head size on the stresses of the periacetabular bone at two selected regions: A1 (superior) and A2 (anterior). Three Finite Element models were developed from CT scan data of a hemipelvis implanted with a cemented all-polyethylene acetabular cup with a 50 mm outer diameter and inner diameter to accommodate three head sizes: 28 mm, 32 mm and 36 mm. The peak reaction force at the hip joint during one leg stand for an overweight patient with a body weight of 100 Kg was simulated for head sizes investigated. We found that highest average von Mises stress was 5.7 MPa and occurred in the cortical bone of region A1 which is located within Zone 1 boundaries (Charnley &DeLee); whereas a lower stress of 4.0 MPa occurred at region A2. In the two regions the stresses were the same for the three head sizes. Periacetabular bone was found to be insensitive to the increase of femoral head diameter in cemented THA.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_9 | Pages 40 - 40
1 May 2018
Del-Valle-Mojica J Alonso-Rasgado T Bailey C Jimenez-Cruz D Board T
Full Access

Introduction

The use of larger femoral heads in Total Hip Arthroplasty has increased in order to reduce the risk of dislocation and to improve the range of motion of the joint. In 2003, within the UK, the “standard” head size of 28mm was used in 73% of all hip procedures, whereas by 2012, this figure dropped to 36%. Concerns regarding the impact of this increment in head size on the cement and bone stresses have arisen; however, this has yet to be clearly determined.

Methods

To understand the relationship between femoral head size and cement mantle and bone stress in cemented hip arthroplasty, 3D-Finite-Element models of a hemipelvis with cemented cup[tb6] (50mm outer-diameter) were developed. Loading conditions of single-leg-stance (average and overweight) were simulated for three head sizes (28, 32 and 36mm). The models were validated with an in-vitro experiment using the average loading condition.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_17 | Pages 24 - 24
1 Nov 2017
Saraogi A Lokikere N Lafferty R Nagai H Pavlou G Board T Jones HW
Full Access

Prosthetic joint infection continues to remain a diagnostic challenge for unhappy primary arthroplasty of hip and knees. There is increasing dependence upon alpha-defensin test to make key decisions like whether to revise or not & to decide between one-stage versus two-stage.

Aim

This study aims to assess diagnostic accuracy of alpha-defensin test in determining prosthetic hip & knee infection and to provide guidance for appropriate use of this novel but expensive investigation.

Methods

Retrospective review of all alpha-defensin investigated patients in an orthopaedic institute between February 2015 & March 2017 was performed. Clinical and radiological outcomes including re-infections, re-operations were analysed and alpha-defensin outcomes were compared with that of other available investigations.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_17 | Pages 10 - 10
1 Nov 2017
Sidharthan S Lokikere N Saraogi A Nagai H Wynn-Jones H Board T Shah N Porter M Kay P
Full Access

Background

One of the major concerns of hinge knees have been reported in literature is mechanical failure. Failure in the form of component fracture (2–10%) and hinge dislocation/ failure are worrisome. In addition, higher risk of aseptic loosening with hinge knee prosthesis has been attributed to stress transfer at bone cement interface.

Methods

Retrospective review of clinical and radiological results of 71 consecutive patients operated at single centre using Smiles hinge knee (Stanmore implants) between 2010 and 2014. Data was collected till the latest follow up. Mechanical failure due to any reason was considered as primary end point. Radiological evidence of aseptic loosening was considered to be one of the surrogate end points.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_12 | Pages 14 - 14
1 Jun 2017
Agrawal P Chacko V Board T
Full Access

Occlusion of the femoral canal is an important step in cemented hip arthroplasty. The goal of occlusion is to allow cement pressurisation and prevent cement egress into the femoral diaphysis. There are numerous designs of cement plugs made out of different materials but there is no consensus or clinical guideline for the choice of cement restrictors. At our centre two types of plugs are used – autologous bone block from femoral canal and the gelatine C-plug (Depuy International). We conducted this study to evaluate the stability of these two plugs and their effect on quality of cementation.

The purpose of our study was to assess retrospectively both the length of the “cement tail” i.e. the length of the cement column distal to the stem tip and the cement mantle quality in both groups.

A retrospective comparative review was designed after approval from the local R & D department. Power analysis indicated that a minimum of 74 patients per group would be needed. A total of 203 consecutive patients were analysed, 89 received an autologous bone block and 114 had C-plugs. Apart from the plugs both the groups were treated similarly with regards to surgical approach, cementing and operative technique. Surgical technique was to achieve adequate pressurisation and a minimum length of cement tail.

Immediate post-operative radiographs were used for analysis. The primary outcome measure was the length of the cement tail, i.e. the length of the cement column from the tip of the stem. The secondary outcome measure was the quality of cementing which was quantified using Barrack's grading.

The data was tested for normality using the Shapiro-Wilk test. The means of cement tail lengths in between the two groups were compared using the Wilcoxon ranked sum test. The cementation grades were compared using ANOVA. The correlation between the length of cement tail and the quality of cementation was calculated using ordinal regression.

Both the groups were similar in terms of age, sex and primary diagnosis. The mean cement tail length was 6.42 (SE 0.71 mms; range-0–31) in the bone block group and 17.11 (SE-1.34 mms; range 0–65.7 mms) in the C-plug group. This difference was statistically significant (p< 0.0001). The proportion of patients with good quality of cementation (grade A) was significantly higher in the bone block group (80.6%) as compared to the C-plug group (56%) (p < 0.0001). There was a negative correlation between the length of the cement tail and the Barrack grade (rho=0.398), indicating that a short cement tail is associated with better quality cementation.

Quality of cementation is of paramount importance in cemented hip arthroplasty. Revision surgery can be more difficult and higher risk in the presence of a long cement tail. We have shown that better quality cementation and shorter cement tails can be achieved with the cheapest of all options for canal occlusion, an autologous bone block and recommend its use.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_12 | Pages 28 - 28
1 Jun 2017
White G Jones HW Board T
Full Access

Synovasure has been designed and validated for use in the diagnosis of periprosthetic joint infection (PJI). It has a reported sensitivity of 97.4% (CI 86.1–99.6%) and specificity of 95.8% (CI 90.5–98.6%), higher than the variable results reported for aspiration by most units. At a cost of £500 per test, we aimed to establish cost-effectiveness and diagnostic accuracy, to determine its role in routine practice.

We developed a protocol for pre-operative aspiration or intra-operative use. Prerequisites for entry were a high index of clinical suspicion for PJI and equivocal standard investigations. All cases were discussed at the lower limb arthroplasty MDT and approved only if use would change clinical management.

Over 15 months, 36 tests were approved for 22 aspirations (5 hip, 17 knee) and 14 intra-operative cases (7 hip, 7 knee). 10/36 had undergone previous revision surgery. 35/36 cases complied with the protocol. All 22 Synovasure aspirations were negative, corresponding to the microbiology in all but one case; thought to be a contaminant. In the intra-operative group there was one true positive and 12 true negative tests, giving a sensitivity of 100% (95% CI 2.5–100%) and a specificity of 100% (95% CI 73.5–100%). Synovasure influenced decision making in 34/36 procedures. One test failed and in another there was evidence of frank infection. In 11 cases no surgery was performed versus a potential two-stage revision and in 21 cases a single rather than two-stage revision was performed. Resulting in estimated savings of £686,690, offset against a cost of £18,000.

The Synovasure test was found to be sensitive and specific and can aid decision-making particularly in complex cases with an equivocal diagnosis of PJI. The use of this test through a robust protocol driven peer review MDT process not only reduces patient morbidity but drives significant efficiency savings.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_11 | Pages 40 - 40
1 Jun 2016
Johal S Siney P Wroblewski B Purbach B Board T Jones HW
Full Access

Introduction

Large acetabular bone defects caused by aseptic loosening are common. Reconstruction of large segmental defects can be challenging. Various implants and operative techniques have been developed to allow further acetabular revision in cases where bone stock is poor. Reconstitution of bone stock is desirable especially in younger patients. The aim of the study was to review the clinical and radiological results of hip revision with structural acetabular bone grafts using fresh frozen allograft and cemented components.

Method

Between 1990 and 2014, 151 first time revisions for aseptic acetabular loosening with acetabular reconstruction with a fresh frozen structural allograft and cemented components were performed at our hospital.

Graft dimensions, number of screws used and socket coverage by the graft were measured on the post-operative AP radiograph.

Follow-up radiographs were analysed for socket loosening, quality of graft union, graft and graft resorption.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_11 | Pages 27 - 27
1 Jun 2016
Barrow J Panchani S Boden R Chitre A Porter M Gambhir A Board T
Full Access

Introduction

A recent paper suggested implanting an uncemented acetabular shell which is 6mm or greater than the native femoral head in total hip arthroplasty (THA) significantly increased the risk of postoperative pain. We retrospectively analyzed 265 Delta ceramic-on-ceramic (DCoC) THA comparing the native femoral head size to the implanted shell and reviewing if the patient suffered with post-operative pain (POP).

Methods

265 consecutive THAs were performed using the Corail and Pinnacle prostheses with DCoC bearing. Native femoral head size was calculated retrospectively on pre-operative radiographs using TraumaCad software. All patients were sent questionnaires requesting information on satisfaction, sounds, postoperative pain and complications. Statistical analysis was then undertaken on the data.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_7 | Pages 104 - 104
1 May 2016
De Almeida S Chong M Board T Turaev A
Full Access

Background

KAR™ prosthesis was introduced following the success of Corail® femoral stem to tackle difficult revision cases (Paprosky type1, 2a, 2b and 3a). The ARTO group reported a success rate of 94% at 17 years follow-up. Only two independent studies reported similar success rate to date.

Purpose

To analyse the short-term performance of the KAR™ prosthesis used in our unit.


The Bone & Joint Journal
Vol. 98-B, Issue 2 | Pages 179 - 186
1 Feb 2016
Berber R Skinner J Board T Kendoff D Eskelinen A Kwon Y Padgett DE Hart A

Aims

There are many guidelines that help direct the management of patients with metal-on-metal (MOM) hip arthroplasties. We have undertaken a study to compare the management of patients with MOM hip arthroplasties in different countries.

Methods

Six international tertiary referral orthopaedic centres were invited to participate by organising a multi-disciplinary team (MDT) meeting, consisting of two or more revision hip arthroplasty surgeons and a musculoskeletal radiologist. A full clinical dataset including history, blood tests and imaging for ten patients was sent to each unit, for discussion and treatment planning. Differences in the interpretation of findings, management decisions and rationale for decisions were compared using quantitative and qualitative methods.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_12 | Pages 43 - 43
1 Nov 2015
Rajpura A Wroblewski B Siney P Board T Jones HW
Full Access

Introduction

Cross linked polyethylene (XLPE) has gained popularity as a bearing surface of choice for younger patients despite only medium term results being available for wear rates. Concern remains regarding the long-term stability and durability of these materials. In order to address these issues we present the longest radiological and clinical follow-up of XLPE.

Patients/Materials & Methods

Since 1986, we have prospectively studied a group of 17 patients (19 hips) that underwent a cemented Charnley low friction arthroplasty using a combination of 22.225mm alumina ceramic femoral head, a modified Charnley flanged stem and a chemically cross-linked polyethylene cup. We now report the 28 year clinical and radiological results.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 170 - 170
1 Sep 2012
Nickinson R Fleming P Siney P Board T Purbach B Wroblewski M Kay P
Full Access

Introduction

We present the outcome of 297 acetabular revisions using bone grafting and cemented acetabular components in 297 patients, with a mean follow-up of 8 years 3 months (5–20 years).

Methods

All patients underwent acetabular revision with allograft bone grafting and insertion of cemented acetabular components. Of the 297 patients, 134 patients (45%) were male and 163 (55%) were female. The mean age of undergoing revision surgery with bone grafting was 60 years (25–87 years). The mean weight at revision surgery was 71.9 kg (40–128 kg). Post-operatively, all patients were reviewed regularly in out-patients, where they were examined clinically for any complications and their radiographs were examined for evidence of graft union, radiological lucency and cup migration.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 286 - 286
1 Jul 2011
Nickinson R Board T Gambhir A Porter M Kay P
Full Access

Aim: To identify the microbiology of infected knee arthroplasty, emerging patterns of resistance over the last decade, and suggest appropriate empirical treatment.

Methods: A retrospective analysis was conducted of 121 patients with microbiologically proven infection, who underwent revision TKA between 1994–2008. The causative organism was identified from microbiological samples and the corresponding sensitivities recorded. The data was then collated to determine the most common causative organisms, changing patterns of antibiotic resistance over the time frame, and the antibiotics currently most effective at treating deep infection. A theoretical model combining gentamicin with other antibiotics was used to determine the most effective antibiotics for use as empirical treatments.

Results: Coagulase negative Staphylococcus (CNS) was the most common causative organism (49%). Staphylococcus aureus (SA) accounted for 13% of cases. The prevalence of CNS appears to be increasing, while that of SA and other organisms is decreasing. Vancomycin and teicoplanin were the most effective antibiotics with overall sensitivity rates of 100% and 96% respectively. Levels of resistance were significantly higher among the antibiotics commonly used in the community. Antimicrobial resistance was higher when the causative organism was CNS, suggesting that MRSE is becoming a problem in knee arthroplasty. Our theoretical model showed that gentamicin combined with vancomycin would be the most effective empirical treatment.

Conclusion: Understanding the microbiology of deep infection of the knee allows surgeons to treat this complication as effectively as possible. Vancomycin and tei-coplanin appear to be the most effective antimicrobials, with relative invulnerability to the development of resistance. Given the effectiveness of these antibiotics, the use of vancomycin in gentamicin bone cement, combined with IV teicoplanin potentially allows for infected knee arthoplasties to be treated with a one-stage procedure. The rational use of antibiotics may help limit the amount of antibiotic resistance which develops in the future.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 110 - 111
1 May 2011
Högemann A Wolfhard U Kendoff D Board T Olivier L
Full Access

Introduction: Dupuytren’s contracture is a common disease in Northern Europe. Partial fasciectomy is often used to treat the whole spectrum of Dupyutren’s disease, although high recurrence rates have been reported. In our department, the majority of patients are treated by total aponeurectomy, which is defined as the complete removal of palmar tissue. It has been found out that apparently normal-looking aponeurosis can also contain an increased proportion of collagen, which may lead to recurrent disease. Consequently, the perceived advantage of total aponeurectomy over partial aponeurectomy is the potential for a lower recurrence rate as all diseased tissue is potentially removed. Against this background, we have reviewed the effectiveness of total aponeurectomy performed on 61 patients.

Patients and Methods: The group of patients available for review consisted of 51 men and ten women with a mean age of 63.0 (range 42–79 years) and with a mean period of 3.45 years (range 1.03–6.39 years) between operation and review. No patient had follow-up of less than 1 year. At follow-up evaluation hands were examined for nodules, cords and retractions of the skin. The active mobility of the joints was determined with a goniometer and the Jamar hand dynamometer was used to measure grip strength in both hands. Sensitivity was examined by means of two-point-discrimination and the DASH-score was used for the analysis of rehabilitation. Patients were also asked about common risk factors for Dupuytren’s disease.

Results: Post-operative complications including haematoma, seroma or necrosis were found in 13.8% of the patients. Recurrence of contracture occurred in 10.8% of the patients and 4.6% of the operated patients presented with a nerve lesion. Nerve irritation was found in 6.2% of the patients. The mean DASH-score was 3.85 (range 0–52.5). Family pre-disposition was an important risk factor for Dupuytren’s disease with 44.3% of patients having a positive family history.

Conclusion: We suggest that total aponeurectomy is a promising alternative to partial fasciectomy with low risk for recurrent disease and slightly increased risk for a nerve lesion.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_I | Pages 59 - 60
1 Jan 2011
Desai A Barkatali B Porter M Board T
Full Access

Introduction: Leg length discrepancy (LLD) following total hip arthroplasty (THA) can lead to disappointed patients, increased dislocation, increased wear and suboptimal function. It is one of the commonest reasons for litigation following THA in the United States. The purpose of this study was to radiologically and functionally assess the efficacy of a simple technique for intra-operative leg length assessment during THA via a posterior approach.

Materials & Methods: This technique was undertaken in 50 consecutive THAs. The pre-and 3 month postoperative LLD was measured on standing AP pelvis radiographs. The results were compared with 50 THAs performed by the same surgeons without using the technique. Pre-and post-operative OHS and UCLA scores were recorded in both groups.

Results: In the control group the mean pre- and postoperative LLD was 9.38 mm and 7.75mm respectively. In the new technique group the mean pre-operative LLD was 11.37 and the post-operative LLD was 1.70mm. The final LLD was significantly less in the new technique group (p< 0.001). Fifteen patients in the control group and three patients in the new technique group had post–operative lengthening. Oxford Hip and UCLA score improvement in new technique group was greater than in the control group (p< 0.05).

Discussion: The technique we introduced to assess leg length intra-operatively has shown to be safe, reliable and accurate. We have nonetheless demonstrated much greater accuracy at providing equal leg lengths and improved functional outcome using this new technique.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_IV | Pages 513 - 513
1 Oct 2010
Desai A Board T Derbyshire B Karva A Porter M
Full Access

Introduction: The clinical results of the modular Charnley Elite total hip system have been the subject of some interest in recent years. Some studies have shown significant subsidence and rotational instability in some stems when used with low-viscosity cement. These unstable stems have been shown to fail early. This purpose of this study is to demonstrate our conflicting clinical results.

Materials and Methods: 616 modular Charnley Elite total hip arthroplasties were inserted between 1995 and 2002 at Wrightington Hospital, which is a tertiary referral centre and centre of excellence for joint replacement in United Kingdom. Both Consultants and trainees performed operations and a variety of surgical approaches were used. Normal viscosity bone cement was used in all patients. All patients were followed up prospectively.

Results: At mean follow-up of 8 years (range 5–12), 471 hips were available for review. 87 patients had died and 12 were lost to follow-up. 2.7% (13 cases) of femoral components and 2.9% (14 cases) of acetabular components had been revised for aseptic loosening. 10 hips (2.1%) underwent revision for deep infection and 2 (0.04%) for recurrent dislocation. The overall survival with aseptic loosening as an end point was 97% and for revision for any reason was 94.5%.

Conclusion: Our results show acceptable clinical survivor-ship for this implant when used with standard viscosity cement. This contrasts with the lower survivorship rates published by other centres. Our result should reassure patients and surgeons alike that this prosthesis can be associated with acceptable results in the medium term.