Revision total hip arthroplasty is a common operation. The MP Link (Waldemar Link, Hamburg, Germany) system is a distally loading, modular, tapered femoral stem component for revision hip surgery. MP Link in revision total hip arthoplasty was investigated clinically, radiologically and with Oxford hip scores. A prospective study was conducted of 43 patients undergoing revision total hip arthroplasty with MP Link prostheses between 2004 and 2010. The patients were operated upon by one of the senior authors (JM, JS, RC). Outcome data was collected in clinic and via patient questionnaires.Aims
Methods
The position of the hip-joint centre of rotation (HJC) within the pelvis is known to influence functional outcome of total hip replacement (THR). Superior, lateral and posterior relocations of the HJC from anatomical position have been shown to be associated with greater joint reaction forces and a higher incidence of aseptic loosening. In biomechanical models, the maximum force, moment-generating capacity and the range of motion of the major hip muscle groups have been shown to be sensitive to HJC displacement. This clinical study investigated the effect of HJC displacement and acetabular cup inclination angle on functional performance in patients undergoing primary THR. Retrospective study of primary THR patients at the RNOH. HJC displacement from anatomical position in horizontal and vertical planes was measured relative to radiological landmarks using post-operative, calibrated, anterior-posterior pelvic radiographs. Acetabular cup inclination angle was measured relative to the inter-teardrop line. Maximum range of passive hip flexion, abduction, adduction, external and internal rotation were measured in clinic. Patient reported functional outcome was assessed by Oxford Hip Score (OHS) and WOMAC questionnaires. Data analysed using a linear regression model.Background
Methods
It is known that excessive varus alignment of the femoral stem in total hip replacement (THR) creates a sub-optimal biomechanical environment which is associated with increased rates of revision surgery and component wear. Little is known regarding the effect of femoral stem alignment on patient functional outcome. Retrospective study of primary THR patients at the RNOH. Alignment of the femoral stem component in-situ was measured subjectively by a consultant musculoskeletal radiologist in both coronal and sagittal planes using post-operative anterior-posterior and lateral pelvic radiographs. Each THR was grouped into valgus, minor-valgus, neutral, minor-varus or varus coronal plane alignment and posterior, minor-posterior, neutral, minor-anterior or anterior sagittal plane alignment. Patient reported functional outcome was assessed by Oxford Hip Score (OHS) and WOMAC questionnaires. Data analysed using a linear regression model. 90 THRs were studied in 87 patients (55 Female). Mean age at THR=62 (22-86). Mean follow-up=17 months (11-39 months). Median OHS=16, WOMAC=8. Coronal plane alignment of the femoral stem was not associated with any change in OHS (p>0.05) or WOMAC score (p>0.05). Sagittal plane alignment of the femoral stem was not associated with any change in OHS (p>0.05) or WOMAC score (p>0.05).Methods
Results
Articular cartilage implantation (ACI) and associated procedures (MACI = Matrix-assisted cartilage implantation) are now established treatments for osteochondral defects in the knee. The quality of repair in terms of histological appearance is frequently not known, whilst the correlation of histology results with functional outcomes remains undefined. Histological data of the quality of the repair tissue is sparse and a precise classification proved difficult. This was a single-centre, prospective study. Over 12 years (1998-2010) 406 patients that underwent articular cartilage implantation procedures at our institution (ACI = 170, MACI = 205) had biopsies taken at the 1-2 year interval, in order to assess whether these contained ‘hyaline-like’ cartilage, ‘mixed hyaline-like with fibrocartilage’, fibrocartilage or fibrous tissue alone. Histological sections of the biopsies were prepared and stained with haematoxylin, eosin and proteoglycan stains and viewed under polarised light. All biopsies were studied by a single histopathologist in a specialist, dedicated musculoskeletal laboratory. All patients were assessed by the Cincinnati, Bentley and Visual Analogue scores both pre-operatively and at the time of the review. The findings revealed that 56 patients healed with ‘hyaline-like’ cartilage (14.9%), 103 with ‘mixed’ (27.5%), 179 with fibrocartilage (47.7%) and 37 with fibrous tissue (9.9%). These findings showed that 42.4% of defects were filled with ‘hyaline-like’ or ‘mixed’ cartilage, with 70% of these achieving a ‘fair’ to ‘excellent’ functional outcome. This was also observed in the fibrocartilage group, where 72% achieved similar results. Predictably 89% of the patients that healed by fibrous tissue had a poor functional outcome. This study shows that 71% of patients whose osteochondral defects healed by either ‘hyaline-like’, ‘mixed’ or fibrocartilage experienced an improvement in the function. In contrast, only 11% of the patients whose defects filled with fibrous tissue, showed some functional improvement. Additionally, this data indicates the advantage of biopsies in assessing the overall results of cartilage implantation procedures.
Patients with osteochondrodysplasia frequently require Total Hip Arthroplasty at a younger age, as a result of early degenerative disease of the hip joint. The outcome of Modular Total Hip Arthroplasty in this group of patients has been reported previously. In this retrospective study we evaluated the outcome of custom made (CADCAM) Total Hip Arthroplasty in patients with osteochondrodysplasia. Between 1974 and 2009, twenty one CADCAM Total Hip Arthroplasty procedures were performed in fourteen patients in our institution. There were eight female and six male patients, with the mean age at time of surgery of 40.95 years (20 to 78). The patients were followed up clinically and with the Harris hip score for a mean of 7.12 years (0.5 to 17 years). Four of the twenty-one hips (23.8%) required revision surgery at a mean of 11.54 years (6.5 to 17 years); one required it for aseptic loosening of the femoral component; one required complete revision of the acetabular component; one required exchange of acetabular liner; and one was for symptomatic non-union of a lesser trochanter avulsion. This study shows encouraging clinical outcomes of custom made (CADCAM) Total Hip Arthroplasty in patients with osteochondrodysplasia,
Non-invasive expandable prostheses for limb salvage tumour surgery were first used in 2002. These implants allow ongoing lengthening of the operated limb to maintain limb-length equality and function while avoiding unnecessary repeat surgeries and the phenomenon of anniversary operations. A large series of skeletally immature patients have been treated with these implants at the two leading orthopaedic oncology centres in England (Royal National Orthopaedic Hospital, Stanmore, and Royal Orthopaedic Hospital, Birmingham). An up to date review of these patients has been made, documenting the relevant diagnoses, sites of tumour and types of implant used. 87 patients were assessed, with an age range of 5 to 17 years and follow up range of up to 88 months. Primary diagnosis was osteosarcoma, followed by Ewing's sarcoma. We implanted distal femoral, proximal femoral, total femoral and proximal tibial prostheses. All implants involving the knee joint used a rotating hinge knee. 6 implants reached maximum length and were revised. 8 implants had issues with lengthening but only 4 of these were identified as being due to failure of the lengthening mechanism and were revised successfully. Deep infection was limited to 5% of patients. Overall satisfaction was high with the patients avoiding operative lengthening and tolerating the non-invasive lengthenings well. Combined with satisfactory survivorship and functional outcome, we commend its use in the immature population of long bone tumour cases.
Polymethyl methacrylate spacers are commonly used during staged revision knee arthroplasty for infection. In cases with extensive bone loss and ligament instability, such spacers may not preserve limb length, joint stability and motion. We report a retrospective case series of 19 consecutive patients using a custom-made cobalt chrome hinged spacer with antibiotic-loaded cement. The “SMILES spacer” was used at first-stage revision knee arthroplasty for chronic infection associated with a significant bone loss due to failed revision total knee replacement in 11 patients (58%), tumour endoprosthesis in four patients (21%), primary knee replacement in two patients (11%) and infected metalwork following fracture or osteotomy in a further two patients (11%). Mean follow-up was 38 months (range 24–70). In 12 (63%) patients, infection was eradicated, three patients (16%) had persistent infection and four (21%) developed further infection after initially successful second-stage surgery. Above knee amputation for persistent infection was performed in two patients. In this particularly difficult to treat population, the SMILES spacer two-stage technique has demonstrated encouraging results and presents an attractive alternative to arthrodesis or amputation.
Patients with skeletal dysplasia are prone to
developing advanced osteoarthritis of the knee requiring total knee replacement
(TKR) at a younger age than the general population. TKR in this
unique group of patients is a technically demanding procedure owing
to the deformity, flexion contracture, generalised hypotonia and ligamentous
laxity. We retrospectively reviewed the outcome of 11 TKRs performed
in eight patients with skeletal dysplasia at our institution using
the Stanmore Modular Individualised Lower Extremity System (SMILES)
custom-made rotating-hinge TKR. There were three men and five women
with mean age of 57 years (41 to 79). Patients were followed clinically
and radiologically for a mean of seven years (3 to 11.5). The mean
Knee Society clinical and function scores improved from 24 (14 to
36) and 20 (5 to 40) pre-operatively, respectively, to 68 (28 to
80) and 50 (22 to 74), respectively, at final follow-up. Four complications
were recorded, including a patellar fracture following a fall, a
tibial peri-prosthetic fracture, persistent anterior knee pain,
and aseptic loosening of a femoral component requiring revision.
Our results demonstrate that custom primary rotating-hinge TKR in
patients with skeletal dysplasia is effective at relieving pain,
with a satisfactory range of movement and improved function. It compensates
for bony deformity and ligament deficiency and reduces the likelihood
of corrective osteotomy. Patellofemoral joint complications are
frequent and functional outcome is worse than with primary TKR in
the general population.
There is limited literature available on the use of metal prosthetic replacements for the treatment of non-traumatic lesions of the proximal radius. This study discusses the implant survivorship and the functional outcome of the elbow following insertion of metal proximal radius endoprostheses performed at the Royal National Orthopaedic Hospital. We present a series of six patients treated with endoprosthetic reconstruction of the proximal radius following resection of non-traumatic pathologies. The patients included four females and two males, with a mean age of 39 years at the time of surgery. Their diagnoses included Ewing’s sarcoma, chondroblastoma, benign fibrous histiocytoma, radio-ulna synostosis and renal carcinoma metastases in two patients. Follow-up extended to 192 months with a mean of 76 months. During this time there were no complications with the prostheses, the most recent radiographs demonstrated secure fixation of the implants and none required revision. One patient developed posterior interosseuous nerve neuropraxia following surgery, which partially recovered, and another patient passed away as a result of disseminated metastatic renal cell carcinoma which was present preoperatively. The patient with radio-ulna synostosis had a 25° fixed flexion deformity of the elbow post-operatively but good flexion, supination and pronation. All other patients had full ranges of movement at the elbow. Functional scores were assessed using the Mayo Elbow Performance Score with patients achieving a mean score of 86 out of 100. The results of the use of proximal radial endoprostheses for treatment of non-traumatic lesions are encouraging with regards to survivorship of the implant and functional outcome of the elbow.
We describe 22 cases of bizarre parosteal osteochondromatous proliferation, or Nora’s lesion. These are surface-based osteocartilaginous lesions typically affecting the hands and feet. All patients were identified from the records of a regional bone tumour unit and were treated between 1985 and 2009. Nine lesions involved the metacarpals, seven the metatarsals, one originated from a sesamoid bone of the foot and five from long bones (radius, ulna, tibia, and femur in two). The mean age of the patients was 31.8 years (6 to 66), with 14 men and eight women. Diagnosis was based on the radiological and histological features. The initial surgical treatment was excision in 21 cases and amputation of a toe in one. The mean follow-up was for 32 months (12 to 162). Recurrence occurred in six patients (27.3%), with a mean time to recurrence of 49 months (10 to 120). Two of the eight patients with complete resection margins developed a recurrence (25.0%), compared with four of 14 with a marginal or incomplete resection (28.6%). Given the potential surgical morbidity inherent in resection, our data suggest that there may be a role for a relatively tissue-conserving approach to the excision of these lesions.
Non-invasive expandable prostheses for limb salvage tumour surgery were first used in 2002. These implants allow ongoing lengthening of the operated limb to maintain limb-length equality and function while avoiding unnecessary repeat surgeries and the phenomenon of anniversary operations. A large series of skeletally immature patients have been treated with these implants at the two leading orthopaedic oncology centres in England (Royal National Orthopaedic Hospital, Stanmore, and Royal Orthopaedic Hospital, Birmingham). An up to date review of these patients has been made, documenting the relevant diagnoses, sites of tumour and types of implant used. 74 patients were assessed, with an age range of 7 – 16 years and follow up range of 4 – 88 months. We identified five problems with lengthening. One was due to soft tissue restriction which resolved following excision of the hindering tissue. Another was due to autoclaving of the prosthesis prior to insertion and this patient, along with two others, all had successful further surgery to replace the gearbox. Another six patients required mechanism revision when the prosthesis had reached its maximal length. Complications included one fracture of the prosthesis that was revised successfully and six cases of metalwork infection (two of which were present prior to insertion of the implant and three of which were treated successfully with silver-coated implants). There were no cases of aseptic loosening. Overall satisfaction was high with the patients avoiding operative lengthening and tolerating the non-invasive lengthenings well. Combined with satisfactory survivorship and functional outcome, we commend its use in the immature population of long bone tumour cases.
We have reviewed five adult patients treated with endoprosthetic reconstruction of the proximal radius following resection of non-traumatic lesions. The patients had a mean age of 33.4 years (20 to 60) at the time of surgery and the mean follow-up was 7.6 years (0.8 to 16). Following surgery, all elbows were clinically stable and there was 100% survivorship of the prosthesis. Evaluation of function was assessed clinically and by the Mayo Elbow Performance Score, achieving a mean of 86% (70 to 100). Results at medium-term follow-up are encouraging with regards to elbow stability, implant survivorship and functional outcome.
Disarticulation of the hip in patients with high-grade tumours in the upper thigh results in significant morbidity. In patients with no disease of the proximal soft tissue a femoral stump may be preserved, leaving a fulcrum for movement and weight-bearing. We reviewed nine patients in whom the oncological decision would normally be to disarticulate, but who were treated by implantation of an endoprosthesis in order to create a functioning femoral stump. The surgery was undertaken for chondrosarcoma in four patients, pleomorphic sarcoma in three, osteosarcoma in one and fibrous dysplasia in one. At follow-up at a mean of 80 months (34 to 132), seven patients were alive and free from disease, one had died from lung metastases and another from a myocardial infarction. The mean functional outcome assessment was 50 (musculoskeletal tumor society), 50 and 60 (physical and mental Short-form 36 scores). Implantation of an endoprosthesis into the stump in carefully selected patients allows fitting of an above-knee prosthesis and improves wellbeing and the functional outcome.
Following resection of tumours in the distal femur, reconstruction with joint-sparing prostheses have shown good short-term functional outcomes. There is however limited literature on the affect of knee-sparing prostheses on function of the distal femoral physis in children of bone growing age. We discuss two patients, a male (11yrs) and female (10yrs) who had joint-sparing distal femoral prostheses inserted for treatment of Ewing’s sarcoma. The knee joint, along with the distal growth plate, was preserved and fixed to the distal end of the prosthesis using uni-cortical screws positioned distal to the physis. In the female, these screws were removed 6 months postop due to prominence of the screws under the skin. In both patients, we assessed radiographs from immediately post[surgery and the most recent follow-up (20 and 28 months respectively). In each set, for the operated limb, we measured the height and width of the distal femoral epiphysis, the total length of the femur and the length of the proximal femoral bone segment from the femoral head to the proximal bone-prosthesis interface. In addition, postoperative assessments of leg lengths, bilaterally, were documented. In both patients, distal femoral epiphyseal height and width in the operated leg showed no significant change following endoprosthetic replacement. In the female, growth did not resume even after removal of the epiphyseal screws. In both patients, lengths of the femur and the proximal bone segment increased significantly following surgery. The patients demonstrated no clinical leg length discrepancy at the most recent follow-up. This study suggests that the function of the distal femoral growth plate ceases following insertion of joint-sparing distal femoral endoprostheses, probably due to trans-physeal fixation. This does not appear to resume following early removal of distal screws. The proximal growth plate, however, continues to function adequately enough to maintain symmetry in overall leg length.
We present a case report of postoperative pain following THR, which was initially diagnosed as infection. The salutary message is that the correct diagnosis was a secondary tumour. A fifty three year old man had a primary right total hip replacement for osteoarthritis, using an uncemented CAD CAM (computer aided design, computer aided manufacture) prosthesis with a Trilogy cup. Postoperatively he recovered uneventfully, with a normal range of movement and good function; there were no radiographic abnormalities noted at the time. Two years after operation, he developed pain in the right thigh. His doctor referred him for investigation of his back, which was normal. He was then seen by an orthopaedic surgeon who diagnosed infection, based on an X-ray that revealed a destructive lesion of the upper femur. He was referred back to the senior author, who felt that the X-ray was more suggestive of tumour than infection; further investigation, with MRI and ultrasound confirmed the presence of a tumour; isotope bone scanning revealed it to be solitary. A needle biopsy showed follicular thyroid tumour to be present; this was confirmed by immunohistochemistry. His past medical history included a history of hemithyroidectomy eight years prior to the hip replacement – this was for what was believed to be a benign thyroid nodule. CT of his chest revealed multiple lung metastases. Review of the X-ray taken six months post-operatively suggests, in retrospect, that the destructive process had already begun. He has been treated with a total thyroidectomy and radiotherapy to the right hip with encouraging early results. He is also having chemotherapy for the pulmonary metastases. Thyroid tumours metastasise by blood and commonly occur in bone; the proximal femur is a frequent site for metastasis. It is likely that the occurrence is coincidental.
We report a surgical technique for arthroplasty of the deformed hip after poliomyelitis. A fifty three year old man presented to our unit with a long-standing history of hip problems since contracting poliomyelitis at the age of two. Unusually, both of his hips were affected. He had been operated on twice for his right hip. This had left him with a deformed upper femur with significant shortening. The right hip was sub-luxed on presentation; this was due to a markedly dysplastic acetabulum. The polio and subluxation meant his muscles were weak and stretched. Like other authors, we were keen to achieve a stable hip. The senior author felt that a fully constrained socket would carry the following disadvantages:
Reduced range of movement. It would be difficult to fit a constrained socket into the small amount of pelvic bone available. Constrained sockets are more likely to loosen. An alternative approach, using a large diameter unconstrained metal on metal articulation, was employed; stability was achieved with the large head and the relatively small socket still preserved bone stock. The components chosen were a 52mm MMT, Birmingham acetabular resurfacing prosthetic, articulating with a 46mm chromium cobalt head. A fluted stem CAD CAM (computer aided design, computer aided manufacture) femoral prosthesis was used, as he needed to fully weight-bear from the outset, because of the weakness in his left leg. He has a good, pain-free range of movement. This represents a novel solution for arthroplasty in hips surrounded by weakened musculature. It avoids dramatic limitation of movement whilst minimising the bone stock loss and risk of dislocation. The patient is delighted with the medium term results.