Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_3 | Pages 154 - 154
1 Jan 2016
Kim H Seon J Seol J Kim G Yoo S
Full Access

Background

Despite the excellent clinical success of total knee arthroplasty (TAK), controversy remains concerning whether or not to resurface the patella. This has led to a number of randomized controlled trials. Randomized controlled trials constitute the most reliable source of evidence for the evaluation of the efficacy of a potential intervention. But most of these studies include all degree of osteoarthritis of the patellofemoral joint. So we did this prospective study to compare clinical and radiological outcomes after TKA with or without patellar resurfacing in patients with grade IV osteoarthritis on patellofemoral joint.

Materials and Methods

123 cases (93 patients) with Kellgren-Lawrence grade IV osteoarthritis on patellofemoral joint were enrolled for this study. At the operating room, they were randomly assigned to undergo patella resurfacing (62 cases) or patella retention (61 cases). Among them, 114 cases that could be followed for more than 2 years were included in this study (resurfacing group; 59 cases, retention group; 55 cases). When patellar retention was performed, osteophytes of the patella were removed and marginal electrocauterization was carried out. Preoperative and postoperative clinical outcomes were evaluated and compared regarding the Hospital for Special Surgery Patellar (HSSP) score (total 100 point; anterior knee pain, functional limitation, tenderness, crepitus, Q-strength). We also compared Hospital for Special Surgery (HSS) and WOMAC scores, and range of motion (ROM). We also compared radiological outcomes at the final follow up, with regards to mechanical axis of the lower limb, patella tilt and patella congruence angle between two groups.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_4 | Pages 23 - 23
1 Jan 2016
Song E Seon J Kim H
Full Access

Background

The most important factors affecting the outcome of a TKA are restoring the normal mechanical axis and achieving optimum soft tissue balance. In the measured resection technique may have accompanying problems in imbalanced patients. Secondly individual variability of the reference points may affect the alignment of the bony cuts and thereby the alignment of the implant. The gap balance technique blends the soft tissue balance with the bony cuts and tries to overcome this problem. However proponents of the measured resection technique argue that no consideration is given to the coronal and rotational alignment of the femoral component in the gap balance technique. The ligament specific navigation assisted gap balance technique, tries to overcome these fallacies. The lateral ligaments and soft tissues act as a reference against which the medial soft tissues are balanced. Thus the reference becomes individualized and any variability is taken care of. Navigation assistance ensures control of the coronal and rotational alignment of the femoral component. The aim of the present study was two fold: - To describe our methodology of ligament specific navigation assisted gap balance technique and analyze the clinico-radiological outcome of our technique over an eight year follow up.

Methods

79 patients (98 knees) with primary osteoarthritis with varus deformity and flexion deformity of were followed up for eight year duration. After obtaining an optimum gap balance and neutral axis in extension, tibial osteotomy perpendicular to the mechanical axis in both the coronal and sagittal planes was done. At this stage joint gaps were distracted in extension and 90â�° flexion. Based on the gap values patients were classified into three groups. Group 1 was the balanced group with flexion extension gap difference ≤2mm, group 2 was the flexion tight group with flexion gap smaller than the extension gap by ≥3mm and group 3 was the extension tight group with the extension gap smaller than the flexion gap by ≥3mm. Thereafter flexion gap balance was achieved only by adjusting the cutting levels of the distal and posterior condyles and adjusting the axial rotation of the femoral component without any further soft tissue release. Intraoperative navigation readings were recorded. All patients were followed clinico-radiologically at 1, 4, and 8 years post operatively.


The Bone & Joint Journal
Vol. 97-B, Issue 7 | Pages 1007 - 1011
1 Jul 2015
Kim H Im SB Han I

Deformity of the proximal femur in fibrous dysplasia leads to deviation of the mechanical axis of the hip, which may lead to the development of secondary osteoarthritis (OA). This study investigated the prevalence and predisposing factors for the development of OA in patients with fibrous dysplasia of the proximal femur. We reviewed the records of 209 patients from our institutional database with fibrous dysplasia of the proximal femur, investigating possible predisposing factors including patient demographics, the extent of the coxa vara deformity, the presence of peri-articular disease, and the overall burden of skeletal disease. Of the 209 patients, 24 (12%) had radiological evidence of OA in the ipsilateral hip. The prevalence was significantly higher in patients with polyostotic fibrous dysplasia compared with those with monostotic disease (p < 0.001). In a subgroup analysis of patients with polyostotic disease, the extent of deformity (quantified using the neck–shaft angle), and the presence of peri-articular disease (whether in the head of the femur or the acetabulum) were significant predictors of osteoarthritis (neck–shaft angle likelihood ratio (LR) = 0.847 per 1° increase, p = 0.004; presence of lesion in the head of the femur LR = 9.947, p = 0.027; presence of lesion in the acetabulum LR = 11.231, p = 0.014).

Our data suggest that patients with polyostotic fibrous dysplasia have a high risk of developing secondary OA of the hips. This risk is higher in patients with peri-articular disease, and those with a more severe deformity of proximal femur.

Cite this article: Bone Joint J 2015;97-B:1007–11.


The Bone & Joint Journal
Vol. 97-B, Issue 1 | Pages 121 - 128
1 Jan 2015
Kang S Han I Hong SH Cho HS Kim W Kim H

Cancellous allograft bone chips are commonly used in the reconstruction of defects in bone after removal of benign tumours. We investigated the MRI features of grafted bone chips and their change over time, and compared them with those with recurrent tumour. We retrospectively reviewed 66 post-operative MRIs from 34 patients who had undergone curettage and grafting with cancellous bone chips to fill the defect after excision of a tumour. All grafts showed consistent features at least six months after grafting: homogeneous intermediate or low signal intensities with or without scattered hyperintense foci (speckled hyperintensities) on T1 images; high signal intensities with scattered hypointense foci (speckled hypointensities) on T2 images, and peripheral rim enhancement with or without central heterogeneous enhancements on enhanced images. Incorporation of the graft occurred from the periphery to the centre, and was completed within three years. Recurrent lesions consistently showed the same signal intensities as those of pre-operative MRIs of the primary lesions. There were four misdiagnoses, three of which were chondroid tumours.

We identified typical MRI features and clarified the incorporation process of grafted cancellous allograft bone chips. The most important characteristics of recurrent tumours were that they showed the same signal intensities as the primary tumours. It might sometimes be difficult to differentiate grafted cancellous allograft bone chips from a recurrent chondroid tumour.

Cite this article: Bone Joint J 2015;97-B:121–8.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 10 - 10
1 Jul 2014
Kim S Hong J Yoon H Kwon B Lee I Kim H
Full Access

Summary Statement

Obovatol inhibits receptor activator of nuclear factor kappa B ligand (RANKL)-induced osteoclastogenesis and prevents inflammatory bone loss in mice

Introduction

Adult skeletal mass and integrity are maintained by balancing osteoclast-mediated bone resorption and osteoblast-induced bone formation during bone remodeling. Abnormal increases in osteoclastic bone resorption can lead to excessive bone destruction as observed in osteoporosis, rheumatoid arthritis, and metastatic cancers Therefore, Modulation of osteoclast formation and function is a promising strategy for the treatment of bone-destructive diseases. To search for compounds that inhibit osteoclast formation, we tested the effect of obovatol, a natural product isolated from the medicinal plant Magnolia obovata, on osteoclastogenesis and inflammatory bone loss.


The Bone & Joint Journal
Vol. 96-B, Issue 5 | Pages 673 - 676
1 May 2014
Han I Choi ES Kim H

Monostotic fibrous dysplasia of the proximal femur has a variable clinical course, despite its reported limited tendency to progress.

We investigated the natural history and predisposing factors for progression of dysplasia in a group of 76 patients with a mean follow-up of 8.5 years (2.0 to 15.2). Of these, 31 (41%) presented with an asymptomatic incidental lesion while 45 (59%) presented with pain or a pathological fracture. A group of 23 patients (30%) underwent early operative treatment for pain (19: 25%) or pathological fracture (4: 5%).

Of the 53 patients who were initially treated non-operatively, 45 (85%) remained asymptomatic but eight (15%) needed surgery because of pain or fracture. The progression-free survival of the observation group was 81% (sd 6.4%) at five-years follow-up. An initial presentation of pain (p < 0.001), a limp (p < 0.001), radiological evidence of microfracture (p = 0.001) and younger age (< 17 years) (p = 0.016) were significant predisposing factors for disease progression.

The risk of experiencing pain or pathological fracture is considerable in monostotic fibrous dysplasia of the proximal femur. Patients presenting with pain, a limp or radiological evidence of microfracture have a high chance of needing surgical treatment.

Cite this article: Bone Joint J 2014;96-B:673–6.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 102 - 102
1 Dec 2013
Kim H Park K Byun J Yoon TR
Full Access

Purpose

The purpose of this study is to evaluate the midterm results of cementless revision total hip arthroplasty (THA) using Wagner Cone Prosthesis.

Material and Methods

Between 1996 and 2007, 36 hips in 36 consecutive patients underwent femoral revision THA using Wagner Cone Prosthesis. Among them 28 hips were followed for more than 5 years. The mean age at revision surgery was 57 years and a mean follow-up was 7.6 years. The Paprosky classification system was used for preoperative bone loss evaluation. Clinical results were evaluated using Harris hip scores. For evaluation of the femoral component, radiolucent lines at bone-implant interfaces were evaluated and femoral component vertical subsidence was measured. Heterotopic bone formation and complications were also evaluated.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 375 - 375
1 Dec 2013
Kim H Park K Byun J Yoon TR
Full Access

Purpose:

The purpose of this study was to evaluate the results of two stage reconstruction for infected arthroplasty of hip joint and to know the risk factor for failures.

Patients and Methods:

From May 2004 to September 2011, 104 consecutive patients (105 hips) who underwent two stage reconstruction for the infected arthroplasty of hip joint were retrospectively evaluated. There were 60 hips with primary THA infection (Acute infection 22, Delayed infection 38), 4 hips with revision THA infection (Acute infection 1, Delayed infection 3), 20 hips with primary hemiarthroplasty infection (Acute infection 14, Delayed infection 6) and 24 hips with acute pyogenic coxitis. We evaluated the number of surgeries before two-stage reconstruction and also analysed the cultured pathogens. Mean follow duration after 2nd stage revision THA was 1.80 ± 1.76 years and average age at the time of 1st stage surgery (Debridement and PROSTALAC insertion) was 62.8 ± 14.3 years.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 10 | Pages 1414 - 1420
1 Oct 2012
Cho HS Oh JH Han I Kim H

We evaluated the oncological and functional outcome of 18 patients, whose malignant bone tumours were excised with the assistance of navigation, and who were followed up for more than three years. There were 11 men and seven women, with a mean age of 31.8 years (10 to 57). There were ten operations on the pelvic ring and eight joint-preserving limb salvage procedures. The resection margins were free of tumour in all specimens. The tumours, which were stage IIB in all patients, included osteosarcoma, high-grade chondrosarcoma, Ewing’s sarcoma, malignant fibrous histiocytoma of bone, and adamantinoma. The overall three-year survival rate of the 18 patients was 88.9% (95% confidence interval (CI) 75.4 to 100). The three-year survival rate of the patients with pelvic malignancy was 80.0% (95% CI 55.3 to 100), and of the patients with metaphyseal malignancy was 100%. The event-free survival was 66.7% (95% CI 44.9 to 88.5). Local recurrence occurred in two patients, both of whom had a pelvic malignancy. The mean Musculoskeletal Tumor Society functional score was 26.9 points at a mean follow-up of 48.2 months (22 to 79).

We suggest that navigation can be helpful during surgery for musculoskeletal tumours; it can maximise the accuracy of resection and minimise the unnecessary sacrifice of normal tissue by providing precise intra-operative three-dimensional radiological information.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 7 | Pages 946 - 949
1 Jul 2012
Chang H Song K Kim H Choi B

This study evaluates factors related to myelopathic symptoms in patients with ossification of the posterior longitudinal ligament (OPLL). A total of 87 patients with OPLL were included. Of these, 53 (Group I) had no symptoms or presented with neck pain and radiculopathy and 34 (Group II) had myelopathic symptoms. Gender, age, and history of trauma were evaluated in the two groups. The range of movement of the cervical spine was measured using plain radiographs. The number of involved segments, type of OPLL, and maximal compression ratio were analysed using CT and signal change in the spinal cord was evaluated using MRI.

The patients’ age was found to be significant (p = 0.001). No difference was found between gender and the range of movement in the two groups. The maximum compression of the spinal canal showed a difference (p = 0.03). The signal change of the spinal cord was different between the two groups. In patients with OPLL of the cervical spine, myelopathic symptoms are not related to the range of movement or the number of involved segments.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 139 - 140
1 May 2011
Fontaine C Wavreille G Titeca M Kim H Chantelot C
Full Access

The distal interphalangeal (DIP) joints of the fingers are prone to functional impotence in some degenerative diseases. In this case, different surgical techniques can be used, from DIP arthrodesis to joint denervation, much more confidential, which aims to preserve an already reduced mobility.

The four fingers (except the thumb) of 6 fresh hands from different cadavers were dissected under optic magnification. Two DIP joints were harvested from fresh dissected hands, in order to follow with the microscope the course of the nerve branchlets up to their articular entry. These two specimens were decalcified, and then embedded in paraffin. The blocks were serially cut in 5μm slices (1 slice each 250μm), which were observed at 25 and x100 magnification, after Masson’s trichrom staining.

A constant proximal articular branch, arising from the proper digital palmar nerve, was exclusively devoted to joint supply. This branch was located medially and arose in average at 7 mm from its entry point in the joint, where it was accompanied by small arterial branches. Before its entry into the inferomedial part of the DIP joint, it ran under the flexor digitorum profun-dus tendon. It then could divide into 2 or 3 branchlets. The proper digital palmar nerve abandoned, along its course, some nerve fibers to the tendinous synovium and neighboring structures. Then, ending its course, it gave off a distal articular branch, hidden among numerous cutaneous branches for the fingertip. The DIP joint nerve supply seems so under the exclusive dependence of the proper digital palmar nerve without any input from the dorsal side. On the histological slices, the nerves were mainly observed in peri- and intracapsular situation.

Could cutting these two articular nerves be sufficient to relieve pain from the DIP? This is what we are investigating through a clinical series; the first results are presented here.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 1 | Pages 120 - 125
1 Jan 2011
Lim H Bae J Song H Teoh SH Kim H Kum D

Medial open-wedge high tibial osteotomy has been gaining popularity in recent years, but adequate supporting material is required in the osteotomy gap for early weight-bearing and rapid union. The purpose of this study was to investigate whether the implantation of a polycaprolactone-tricalcium phosphate composite scaffold wedge would enhance healing of the osteotomy in a micro pig model. We carried out open-wedge high tibial osteotomies in 12 micro pigs aged from 12 to 16 months. A scaffold wedge was inserted into six of the osteotomies while the other six were left open. Bone healing was evaluated after three and six months using plain radiographs, CT scans, measurement of the bone mineral density and histological examination.

Complete bone union was obtained at six months in both groups. There was no collapse at the osteotomy site, loss of correction or failure of fixation in either group. Staining with haematoxylin and eosin demonstrated that there was infiltration of new bone tissue into the macropores and along the periphery of the implanted scaffold in the scaffold group. The CT scans and measurement of the bone mineral density showed that at six months specimens in the scaffold group had a higher bone mineral density than in the control group, although the implantation of the polycaprolactone-tricalcium phosphate composite scaffold wedge did not enhance healing of the osteotomy.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_I | Pages 12 - 12
1 Jan 2011
Forward D Doro C O’Toole R Floyd J Kim H Hsieh A Nascone J
Full Access

Comminuted subtrochanteric fractures pose a clinical challenge; locking plate technology has been theorized to offer treatment advantages. A comminuted subtrochanteric femoral fracture model was created with a 2 cm gap below the lesser trochanter in fifteen matched pairs of human cadaveric femora confirmed to be non-osteoporotic. The femora were randomized to treatment with a trochanteric femoral nail (TFN), proximal femoral locking plate (PFLP), or 95° angled blade plate (ABP). Each was tested under incrementally increasing cyclic load up to 90,000 cycles to simulate progressive weight bearing during three months.

The TFN was the strongest implant: it withstood significantly more cycles, failed at a significantly higher force, and withstood a significantly greater load than either plate (p< 0.001). Varus collapse was significantly lower in the TFN construct (p< 0.0001). Mode of failure differed among implants, with damage to the femoral head through implant cut-out in five of ten blade plate specimens and two of ten nail specimens, whereas no damage to the femoral head bone was observed in any of the PFLP specimens.

The TFN was biomechanically stronger than the PFLP and this may have clinical relevance during the slow healing of subtrochanteric femoral fractures. The PFLP was biomechanically equivalent to the ABP but failure occurred without significant damage to the femoral head, suggesting that although biomechanically equivalent, the PFLP might have clinically relevant advantages in its mode of failure over the ABP.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_IV | Pages 595 - 595
1 Oct 2010
Hofstaetter J Kim H Klaushofer K Roschger P
Full Access

Background: Traditionally, it is believed that structural failure of the ischemic epiphysis as well as changes in radiodensity seen in Legg-Calve-Perthes disease are due to repair. Little is known if bone material properties are altered following ischemic necrosis of the juvenile femoral head. Purpose of this study was to determine bone matrix mineralization density, an important determinant of bone quality and strength, in an experimental model of juvenile ischemic osteonecrosis.

Methods: Ten piglets were surgically induced with ischemic osteonecrosis and euthanized at 4- and 8 weeks following surgery. Contralateral, unoperated femoral heads were used as controls. Bone Mineralization Density Distribution (BMDD) parameters were determined using quanitative backscattered electron imaging (qBEI) in the epiphyseal calcified cartilage, subchondral and central trabecular bone region. Histological assessment was also performed.

Results: In necrotic calcified epiphyseal cartilage matrix as well as subchondral bone matrix, a significant increase in the degree (CaMean, Ca Peak) as well as the homogeneity of mineralization (CaWidth reduction) and a significantly reduced amount of low mineralized matrix (CaLow) were observed at 4 and 8 weeks post ischemia induction. In the necrotic central trabecular region a significant increase in the degree and homogeneity of mineralization, as well as a decrease in the amount of low mineralized bone was found at 8 weeks post-ischemia induction, but not at 4-weeks, indicating that changes in necrotic trabecular bone occur more slowly. Changes in the necrotic calcified cartilage region were more dramatic than in necrotic bone.

Discussion: Our findings indicate that the mineralization process continues in the necrotic calcified cartilage and bone following femoral head infarction. This leads to an increased degree and homogeneity of mineralization in calcified cartilage and bone matrices and therefore altered material properties. These alterations in matrix mineralization status would lead to more brittle bone, prone to micro-fractures and may partly explain the weakening of structural properties of necrotic bone. Moreover, an increase in calcified cartilage and bone mineralization may also explain the increased radiodensity seen in the early stage of Perthes disease prior to repair and/or structural failure.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 139 - 139
1 Mar 2010
Lim Y Kwon S Sun D Kim S Kim H Kim Y
Full Access

The osseointegration of implants is related to the early interactions between osteoblastic cells and titanium surfaces. The behavior of osteoblast cells was compared on four different titanium surfaces in vitro and in vivo: machined, blasted, plasma spray and micro-arc oxidation.

X-ray diffraction and scanning electron microscope investigations were performed in order to assess the structure and morphology. Biologic and morphologic responses to the osteoblast cell lines (Saos-2) were then examined, using Promega proliferation assay, alkaline phosphatase activity, vβ3 integrin expression and cytoskeleton staining (Rhodamine-Phallodine). The analysis of gene expression for osteocalcin and collagen I was done through RT-PCR. In addition, differential histologic evaluation and interfacial strength at the bone-implant interfaces were then evaluated in the distal femur of four beagle dogs.

In conclusion, micro-arc oxidation of titanium appears to exhibit more favorable osteoblast adhesion and stronger interfacial strength than the compared groups in vitro and in vivo as well.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 93 - 93
1 Mar 2010
Lim Y Kwon S Han S Han C Kim H Kim Y
Full Access

Biocompatibility of Co-Cr alloy was significantly improved by forming rough TiO2 layer on the surface. The TiO2 layer was formed by coating the Co-Cr alloy with Ti through electron beam deposition followed by micro-arc oxidation (MAO) of the Ti. Biocompatibility of Co-Cr alloy was enhanced by coating with titanium, and it was improved further by micro-arc oxidation treatment. MAO process was dependent on the thickness of coated titanium layer and applied voltage. There were close relationships between the phase, morphology and thickness of TiO2 layer and the applied voltage. Biocompatibility of the specimens coated with Ti and MAO treated after Ti coating were evaluated by in vitro ALP activity tests.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 136 - 136
1 Mar 2010
Kim H Kim J Seol Y
Full Access

Uncontained peripheral bone defect in posteromedial tibial plateau is not an infrequent problem even in primary total knee arthroplasty, especially in Korean patients some of those have large angular deformities preoperatively.

We reviewed the clinical and radiological results of primary total knee replacements of 33 osteoarthritic knees in 28 patients with the use of metal block augmentation for uncontained peripheral tibial bone defects more than 5 millimeters in depth and more than a quarter of medial tibial plateau in width. Those defects were encountered in 75 knees (9.6%) during 779 primary total knee arthroplasties performed by single surgeon between January 2002 and December 2004 at our institution. Modular metal block augmentation was reserved for 42 knees, while the other knees were managed with bone-grafting or cement-filling techniques. Clinical and radiological follow-up more than 12 months were available from 33(78.6%) of 42 knees.

At a mean of 32.2 months (range:12~75 months), 31 knees (93.9%) except two cases of failure were evaluated as good or excellent. The average pre-operative American Knee Society Knee and Function scores were 32.5 and 38.6 respectively, which increased to 82.9 and 79.8 respectively at the latest follow-up. There were no radiolucent lines (RLLs) beneath the metallic block or tibial tray, which were progressive or more than 2 millimeters on radiographs, in those knees. Revisions were required for one delayed infection and another aseptic loosening of tibial component.

Non-progressive RLLs less than 2 millimeters at the cement-bone interface beneath the metallic block were noted in 10 (32.3%) of 31 knees. The RLLs appeared in 5 (41.7%) of 12 knees with metallic block augmentation alone and 5 (26.3%) of 19 knees which had been treated with the use of additional intramedullary stem augmentation, although this difference was not statistically significant. Since these radiolucent lines were not progressive or symptomatic at all, their clinical meanings or long-term consequences are not determined yet. All knees managed with the additional intramedullary stem augmentation revealed to have radiopaque lines adjacent to the stem on follow-up radiographs. The sclerotic halo around the tip of stem could be interpreted as evidence of the stem’s function in load sharing and might reflect secure fixation of tibial tray to bony interface.

We concluded that the use of modular metal block augmentation devices for peripheral tibial defects measuring more than 5 millimeters could provide a simple, rapid and dependable technique that provides predictable results. The observation that all knees managed with additional intramedullary stem augmentation would have sclerotic halo adjacent to the stem on follow-up radiographs may reflect an intramedullary stem is an important adjunct to bone defect management.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 138 - 138
1 Mar 2010
Kim H Kim A Youn I Choi K
Full Access

Personalized three-dimensional (3D) femoral geometry is a great aid in the surgical planning. X-ray image is still essential to diagnose and plan surgery in total hip replacement due to its lower cost and lower dose of radiation than computer tomography (CT). The purpose of the current study is to improve 3D reconstruction process using conventional X-ray images incorporating the anatomical parameters for building up the femoral model.

For 3D reconstruction, the personalized femoral appearance and parameters were firstly prepared from X-ray images and the referential CT model with anatomical parameters was modified as follows: the axial scaling, shearing transformation and radial scaling. In this study, the reconstruction algorithm was applied to X-ray images obtained from the 28 years old male.

The current study showed that this 3D reconstruction technique is clinically useful and feasible because this method was based on anatomical parameters and used for whole femur. This result can provide the basic model of individual femur for using finite element method of hip or knee joint, and designing the customized hip and knee implant. In addition, this result can be applied to the visualized 3D model with more effective parameters of individual femur in the surgery navigation system.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 104 - 104
1 Mar 2010
Kim H Kwon Y Yoo J Ha Y Koo K Yoon K
Full Access

We evaluated 3 cases of ceramic-on-ceramic THA in that the evidence of the impingement between the metal neck and the ceramic liner was found.

Between July 2007 and January 2008, impingement between the metal and the ceramic liner was found in 3 cases of ceramic-on-ceramic THA during re-operation. The re-operation was performed 3–6 years after the primary surgery because of ceramic head fracture, deep infection and cup loosening. All patients frequently sat on the floor in tailor fashion but did not have any sound in the hip after THA.

In all cases, V-shaped indented wear scar was found on the postero-superior aspect of the metal neck. Two ceramic liners could be retrieved. Both showed black staining in the postero-superior portion of the rim. The outer edge of the bearing surface of the retrieved acetabular liners was evaluated with SEM. The black stained area of the acetabular liner rim was found to be roughened. A micro-crack propagating into the deep portion of the ceramic liner was observed in one liner.

Our observations suggest that impingement between the ceramic liner and the metal neck can cause crack formation leading to ceramic liner failure in vivo.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 133 - 133
1 Mar 2010
Moon E Kim J Kim N Park J Park S Kim H Kim H Lee H Moon S
Full Access

Many reports show good results following procedures, such as intervertebral body fusion using cage or total disc replacement, that restore adequate disc height. However, there have been no references regarding the range of normal lumbar disc height in Korean adults which can be used as a standard for the implant size. The purpose of our study is to measure the lumbar disc height on radiographs in normal Korean. 132 subjects (age range 20 to 40 years) who had no previous history of low back pain and no significant finding on physical examination were enrolled. Plain lateral lumbar spine radiograph in supine position were taken. Intervertebral disc heights were measured at anterior, middle and posterior portion of each lumbar disc. The average magnification rate was 115%, and the disc heights were corrected by the magnification rate in each segment.

Lumbar disc height showed cranio-caudal pattern in both male and female groups. L4–5 disc heights were highest at anterior, middle and posterior portion in male. L4–5 disc heights were highest at middle and posterior portion in female. L5-S1 disc height was highest at anterior portion in female, but there was no statistically significant difference between L4–5 and L5-S1 disc height at anterior portion. There was no significant difference in disc height between male and female except anterior portion of L1–2 and L2–3 disc. Statistically significant decrease in disc height was not presented in overweight person at all measured site in male and female except posterior portion of L1–2 disc in male.

This research is meaningful in that it is an attempt to provide a reference value of lumbar disc height in Korean adults, and the measured values may also be useful in manufacturing Korean modeled artificial lumbar disc prosthesis or surgical instruments for lumbar interbody fusion.