Anterior Lumbar Interbody Cages are used to recreate the lumbar lordosis in scoliosis surgery as anterior instrumentation is usually kyphogenic. We report two cases in which an anterior release was performed and interbody cages were used.In both these patients the cage was displaced anteriorly by an incorrectly positioned pedicle screw during posterior instrumentaion. In one case the cage was retrieved and correctly repositioned from the back using a TLIF approach, in the other this was noticed only post-operatively and patient needed another anterior surgery. We recommend a lateral Image Intensifier screening for combined anterior and posterior cases in which anterior cages are used in addition to posterior pedicle screws to prevent this complication.
Routine inclusion of imaging of the SI joint as part of lumbosacral spine MRI for back pain and sciatica shows only 3% positive results. SI joint should be imaged only if clinically suspected.
Paravertebral anaesthesia is a particularly effective, safe and reliable option in scoliosis patients undergoing anterior release in whom percutaneous epidural placement may be difficult to perform. A recent systematic review and meta-analysis of randomized trials has demonstrated that whilst paravertebral block and thoracic epidural insertion provide comparable pain relief after thoracic surgery, paravertebral block placement is associated with a better side effect profile, including a reduction in pulmonary complications, hypotension, nausea and vomiting and urinary retention. We describe a case of a 16 year old female patient who underwent staged correction of her thoracolumbar scoliosis. A paravertebral catheter was inserted under direct vision for continuous infusion post operative analgesia following the anterior release. 48 hours after surgery a swelling was noted in the groin, which was confirmed with ultrasonography as a fluid collection. The swelling resolved upon removing the paravertebral catheter. This suggests that it was caused by the local anaesthetic fluid tracking along the psoas muscle. Retroperitoneal infections, venous thrombosis, femoral hernia, femoral artery aneurysm and inguinal lymphadenopathy are other differentials. Ultrasonography was a fast and sensitive investigation to rule out these differentials and determined that fluid communicating with the abdominal cavity was the cause for this swelling. The infused local anaesthetic had tracked down into the femoral triangle and the swelling resolved upon cessation of the infusion.
Average age was 6.5 years(2–12). Average follow-up was 24 months (6m-36m).
Five specimens were implanted for each group 1) with pedicle screw (into L3 and L5) and tested with/without Synex (expandable) cage anteriorly, 2) implanted with a Synex cage and Double screw+rod Ventrofix system, 3) Synex cage and Double screw+ Single rod Ventrofix construct and 4) Synex cage and Single screw+ Single rod Ventrofix system.
The double screw/ single rod system is less effective than the Ventrofix System but is comparable to the pedicle screw construct. The single screw/ single rod construct leads to unacceptable movement about the axis of the inferior screw particularly in extension with a ROM much greater than the intact spine (p<
0.001)
We studied the correction achieved and the maintenance of the correction at a minimum 15 months follow up using the Paediatric USS.