The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 4 | Pages 455 - 459
1 Apr 2006
Shetty NR Hamer AJ Kerry RM Stockley I Eastell R Wilkinson JM

The aims of this study were to examine the repeatability of measurements of bone mineral density (BMD) around a cemented polyethylene Charnley acetabular component using dual-energy x-ray absorptiometry and to determine the longitudinal pattern of change in BMD during the first 24 months after surgery.

The precision of measurements of BMD in 19 subjects ranged from 7.7% to 10.8% between regions, using a four-region-of-interest model. A longitudinal study of 27 patients demonstrated a transient decrease in net pelvic BMD during the first 12 months, which recovered to baseline at 24 months. The BMD in the region medial to the dome of the component reduced by between 7% and 10% during the first three months, but recovered to approximately baseline values by two years.

Changes in BMD in the pelvis around cemented acetabular components may be measured using dual-energy x-ray absorptiometry. Bone loss after insertion of a cemented Charnley acetabular component is small, transient and occurs mainly at the medial wall of the acetabulum. After two years, bone mass returns to baseline values, with a pattern suggesting a uniform transmission of load to the acetabulum.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 3 | Pages 310 - 313
1 Mar 2005
Buckley SC Stockley I Hamer AJ Kerry RM

We report the results of the revision of 123 acetabular components for aseptic loosening treated by impaction bone grafting using frozen, morsellised, irradiated femoral heads and cemented sockets. This is the first large series using this technique to be reported. A survivorship of 88% with revision as the end-point after a mean of five years is comparable with that of other series.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 2 | Pages 171 - 174
1 Feb 2005
Hoad-Reddick DA Evans CR Norman P Stockley I

All major studies have incorporated the use of prolonged courses of parenteral or oral antibiotic therapy in the management of two-stage revision of an infected total knee arthroplasty. We present a series of 59 consecutive patients, all with microbiologically-proven deep infection of a total knee arthroplasty, in whom a prolonged course of antibiotic therapy was not routinely used. The mean follow-up was 56.4 months (24 to 114).

Of the 38 patients who underwent a staged exchange, infection was successfully eradicated in 34 (89%) but recurrent or persistent infection was present in four (11%). Our rate of cure for infection is similar to that reported elsewhere. We conclude that a prolonged course of antibiotic therapy seems not to alter the incidence of recurrent or persistent infection. The costs of the administration of antibiotics are high and such a regime may be unnecessary.


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 7 | Pages 962 - 965
1 Sep 2004
Ammon P Stockley I

A two-stage procedure was carried out on 57 patients with confirmed infection in a hip replacement. Allograft bone was used in the second stage. Pathogenic organisms were identified in all patients. In stage 1, the prosthesis was removed together with infected tissue. Antibiotics were added to customised cement beads. Systemic antibiotics were not used. At the second stage, 45 of the patients had either acetabular impaction grafting, femoral impaction grafting or a combination; 12 had a massive allograft.

Eight patients suffered recurrent infection (14%), in six with the original infecting organism. The risk factors for re-infection were multiple previous procedures and highly resistant organisms. We believe that systemic antibiotic therapy should be considered for these patients. Allograft bone is shown to be a useful adjunct in most infected hip replacements with considerable loss of bone stock.


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 3 | Pages 337 - 343
1 Apr 2004
Graham NM Stockley I

Between April 1992 and November 1998 we used 34 massive proximal femoral allografts for femoral reconstruction at revision hip arthroplasty. Seven patients have died and two have been lost to follow-up. There were thus 25 grafts in 24 patients for review. The mean follow-up was 53 months (16 to 101). By the time of the review two patients had undergone a further revision for failure of the allograft. Another had required secondary plating and grafting at the graft-host junction for symptomatic nonunion. One had recurrence of deep sepsis and was being managed conservatively.

Trochanteric union was considered to have occurred radiologically in 16 of the 25 grafts and union at the host-graft junction in 20. Resorption of the allograft was significant in only two hips. We recommend this technique in cases in which femoral bone loss has been catastrophic.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_I | Pages 70 - 70
1 Jan 2004
Gordon A Wilson AG Stockley I Hamer AJ Macdonald DA Eastell R Wilkinson JM
Full Access

Aseptic loosening due to periprosthetic bone loss is a major cause of implant failure after total hip arthroplasty (THA). Interleukin 1-B (IL-1B) is thought to play a role in aseptic loosening by stimulating the activity of osteoclasts, the main bone resorbing cell type. A restriction fragment length polymorphism due to a C/T single base variation at +3954 in exon 5 of the IL-1B gene has been associated with differences in susceptibility to chronic periodontitis, a condition associated with bone loss. In this study we tested whether carriage of the C and T alleles at this site resulted in differential risk of aseptic loosening in 481 Caucasians (214 failed versus 267 radiologically intact implants) at 11.7± 4.1 years following primary cemented THA for osteoarthritis. Genomic DNA extracted from peripheral blood was genotyped using the Taqman 5′ nuclease method. Carriage rates were calculated and analysed using the 2 test.

In the intact implant group the frequency of the T allele was 0.253. The distribution of the C and T alleles was 147:105:15 (CC:CT:TT, respectively). In the failed implant group the frequency of the T allele was 0.241). The distribution of the C and T alleles was 124:77:13. The carriage rate of the T alleles in each group was 44.9% and 42.1%, respectively (odds-ratio P> 0.05). The genotype frequencies were in Hardy-Weinberg equilibrium for both intact and loose implant populations (Chi-squared P> 0.05).

Using the multivariate Cox proportional hazards model significant risk factors for loosening of both implant components included gender and age at THA (P< 0.05). However, carriage of the +3954 allele was not a significant independent risk factor for aseptic loosening (P> 0.05). Our data suggests that the IL-1B gene restriction fragment length polymorphism at +3954 does not influence the risk of aseptic loosening after THA.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_I | Pages 69 - 69
1 Jan 2004
Ali F Kerry RM Cooper R Wilkinson JM Norman PA Stockley I
Full Access

Purpose: The role of hip aspiration as a preoperative investigation for the painful hip remains controversial. Since 1999, we have performed hip aspiration under local anaesthetics in the X-ray department. This paper reviews our experience with this technique.

Results: Hip aspirations were carried out subsequently on 182 patients from November 1999 to November 2002. Out of 68 patients that underwent revision hip surgery, 63 were included in the study. Three of the five patients excluded had received antibiotics at induction prior to obtaining the operative samples and two did not have any operative samples taken at the time of surgery. Fifteen (23.8%) of the 63 hips were found to be infected based on operative tissue cultures. The sensitivity and specificity of the test were 80% and 87.5%, respectively. Positive and negative predictive values were 66.6% and 93.3% respectively and the accuracy was 85.7%.

Conclusion: Hip aspiration in the Radiology department is a simple, cost effective and reliable preoperative test when used selectively. When used in combination with other laboratory and radiological investigation it can act as an important preoperative investigation in the diagnosis of sepsis. There is an added advantage of identifying the microorganism along with its antibiotic sensitivities. This can guide clinicians in choosing the correct antibiotic for the cement and also for the postoperative antibiotic therapy.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_I | Pages 71 - 71
1 Jan 2004
Gordon A Kiss-Toth E Wilson AG Stockley I Hamer AJ Eastell R Wilkinson JM
Full Access

Polyethylene wear particle-induced osteolysis is a major cause of implant failure after total hip arthroplasty (THA). Tumour necrosis factor (TNF) is a pro-inflammatory cytokine that is thought to play a pivotal role in this process. We have recently shown that carriage of the −238 ‘A’ allele in the TNF gene promoter is associated with a higher rate of osteolysis after THA versus carriage of the [more common] ‘G’ allele. The aim of this study was to determine the effect of this polymorphism on TNF gene transcriptional activation in response to polyethylene particle stimulation using a luciferase reporter gene assay.

A 691 bp fragment (−585 to +106) of the TNF gene was amplified by polymerase chain reaction and directionally cloned into the PGL3.basic vector (Promega, Madison, WI). Insert sequences were checked using an ABI 377 DNA sequencer (PE Applied Biosystems, Foster City, CA). RAW264.7 murine macrophage-like cells in rapid growth phase were transfected with plasmids containing either the TNF-238G allele or the TNF-238A allele. pTK-RL (Promega), that expresses the Renilla luciferase gene under the control of Herpes simplex virus minimal promoter, was used as a transfection control. The cells were then either left unstimulated or were induced using polyethylene particles generated from a hip simulator. Lipopolysaccharide (LPS) and LTA (Lipoteichoic acid) were used as positive controls. Luciferase reporter activity was measured after 4 hours (Dual luciferase assay, Promega Corp., Southampton, U.K.) and the relative firefly luciferase activity was calculated. Results were analysed using repeated measures ANOVA.

Polyethylene particle stimulation at concentrations of 0, 1, 15, and 30mg/mL resulted in relative luciferase activities (mean (SD)) of 21.4 (2.9), 36.2 (8.2), 45.9 (11.1), and 40.7 (5.1) for the −238A allele; and 19.7 (5.0), 26.4 (8.0), 35.9 (2.3), and 32.4 (2.4) for the −238G allele (ANOVA P=0.01). LPS and LTA stimulation also resulted in increased reporter activity for −238A versus −238G (ANOVA P=0.02 and P=0.04, respectively).

The promoter allele TNF-238A results in higher levels of transcriptional activation versus the TNF-238G allele in response to a clinically relevant stimulus, and provides functional evidence for the significance of this polymorphism in the development of osteolysis after THA.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_I | Pages 72 - 72
1 Jan 2004
Aspinall GR Nicholls A Kerry RM Hamer AJ Stockley I
Full Access

The Huckstep ( Bbraun Medical) interlocking hip prosthesis has been used in the Sheffield Lower Limb Arthroplasty Unit in cases of complex primary and revision hip arthroplasty since 1996. We reviewed the outcomes in cases performed prior to October 2001.

Eighty cases were identified. Of these, eight died within one year of surgery, four of which were in the peri operative period. A further thirteen were lost to follow up in the first year due to medical deterioration, move from area or refusal to attend. The remaining 57 patients had a mean time to follow up of 34 months (12–81m).

As a primary prosthesis the Huckstep was used to allow corrective osteotomy. In revision cases it was employed to bypass periprosthetic fractures and fragile proximal femoral bone, in cases requiring extended trochanteric osteotomy to facilitate cement removal, and to enable use of bulk proximal femoral allograft. The use of the Huckstep was planned pre operatively in 67 cases and as a salvage option in 13.The design of the implant allowed a stable construct without the need for bone cement which could interpose and prevent bone healing or graft incorporation. It avoids problems incurred in pressurising cement or impaction grafting against fragile bone.

Complications included infection requiring further surgery (5), dislocation (5), periprosthetic fracture (2), screw breakage (4), and mechanical failure (2). Eleven patients required further revision surgery. The apparently high complication rate reflects the complex nature of the surgery and the high degree of co morbidity in the elderly patient group.

In conclusion, we have found the Huckstep hip prosthesis to be a useful option in cases of complex hip surgery. Whilst the long term outcome is as yet unknown, our short term results show it to have allowed healing of fractures, osteotomy sites and cortical defects, allograft incorporation and replenishing of bone stock, hence facilitating further arthroplasty surgery.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_I | Pages 68 - 68
1 Jan 2004
Buckley S Hamer A Kerry R Stockley I
Full Access

One of the major surgical challenges at revision arthroplasty is the management of bone stock loss in the acetabulum.

There are several options available for reconstruction; cemented sockets within thick cement mantles, custom sockets jumbo uncemented sockets, support rings and bone grafting. Slooff and others have shown good results with impaction grafting.(JBJS 80B 1998)

If one is to use bone graft, does the preparation of the graft have any effect on the graft itself? There are a number of ways bone can be presented, freeze dried, fresh frozen or frozen irradiated. Concerns have been raised that irradiated bone has an altered and weakened structure. There is a paucity of clinical results on this subject. In this study we present a series of patients using gamma irradiated bone for reconstruction.23% of the cases reconstructions secondary to failure due to sepsis.

Between 1987 and 2000 192 revision arthroplasties in 165 patients were performed with irradiated morcellised bone allograft for acetabular reconstruction. Only those patients with a minimum follow up of 24 months were reviewed. Clinical and radiological follow up was achieved in 130 hips in 115 patients. 9 patients had died at a range of 1 to 66 months after surgery. There were 23 (17%) re-revisions of the acetabular component. Of these 13 were for deep sepsis, 5 for persistent early dislocation and 4 for aseptic loosening. Of those hips revised for infection there was a 13% re-revision rate for reinfection. There was only one catastrophic failure of the graft and only three re-revisions for aseptic loosening to date.

We feel that impaction grafting of the acetabulum is a useful technique for reconstruction even when the index arthroplasty failed for sepsis. We have found no evidence to show that gamma irradiated bone performs any worse than other types of allograft bone.


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_I | Pages 60 - 60
1 Jan 2003
Wilkinson JM Wilson AG Stockley I Scott IR Macdonald DA Hamer AJ Eastell R
Full Access

Tumour necrosis factor-α (TNF) is thought to play a role in aseptic loosening, the major cause of implant failure after total hip arthroplasty (THA). Natural sequence variations at –238 and –308 in the promoter region of the TNF gene are associated with differences in the susceptibility and severity of several TNF-mediated diseases. We tested whether carriage of the [less common] ‘A’ allele at –238 and –308 are associated with aseptic loosening after THA.

481 Caucasians (214 with failed implants versus 267 with radiologically intact implants) were recruited 11.7± 4.1 years after cemented THA for osteoarthritis. Genomic DNA was extracted from peripheral blood and genotyped for the –238 and –308 polymorphisms using the Taqman® 5′ nuclease method. 500 subjects from the local population were also genotyped using Taqman® to establish the background prevalence of the ‘A’ allele at each site.

The carriage rate of –238A was 8.8% in the background population and 10.9% in the THA controls (P> 0.05). –238A carriage in the loosening group was 17.3% (odds ratio 1.72, 95% confidence interval 1.02 to 2.90). Carriage was highest (20.5%) in subjects with loosening of both the femoral and pelvic implant components (odds ratio 2.12; 1.17 to 3.83). The association of –238A with aseptic loosening was independent of age, sex, and amount of implant wear (Cox hazard ratio 1.49 (1.04 to 2.13; P=0.03)). Carriage of –308A was not associated with aseptic loosening.

Genetic, as well as environmental factors, influence implant failure after THA. Whether the –238 polymorphism causes the biological change that predisposes to loosening, or is in linkage disequilibrium with such a locus, is not yet known.


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_I | Pages 34 - 34
1 Jan 2003
Wilkinson J Stockley I Peel N Hamer A Elson R Barrington N Eastell R
Full Access

An acute phase of periprosthetic bone loss occurs following total hip arthroplasty (THA). Periprosthetic bone loss undermines implant support, may contribute to its failure, and complicates revision surgery as allograft may be required to replace lost bone. We assessed the effect of a single 90mg dose of the bisphosphonate pamidronate on early periprosthetic bone mineral density (BMD), biochemical markers of bone turnover, and clinical outcome in 47 men and women undergoing hybrid THA in a randomised, double-blinded, placebo-controlled trial.

The mean (± 95% CI) differences in BMD (area under BMD change.time curve) between those receiving pamidronate and those receiving placebo was 0.91(± 0.51) g.weeks/cm2 for the proximal femur (P=0.002), and 0.80 (±0.60) g.weeks/cm2 for the pelvis (P=0.009). Patients in the pamidronate group had suppression of all biochemical markers of bone turnover compared to placebo (P< 0.05), except for urinary free deoxypyridinoline. Both treatment groups experienced similar improvement in Harris hip and SF-36 UK outcome scores. The frequency of adverse events was similar in each treatment group (placebo 7/24, pamidronate 8/23, P> 0.05).

Acute periprosthetic bone loss following THA is due to a transient increase in bone turnover. A single dose infusion of pamidronate in the early post-operative period significantly reduces this bone loss, and is well tolerated.


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_I | Pages 59 - 59
1 Jan 2003
Wilkinson JM Stockley I Hamer AJ Elson RA Eastell R
Full Access

Factors that allow the generation or ingression of wear particles at the implant-host interface after total hip arthroplasty (THA) may include early migration and periprosthetic bone loss. We have previously shown that a single 90mg dose of the bisphosphonate pamidronate prevents bone loss over 6 months after THA. In this 2 year randomised trial extension study we assessed the longer term effects of this intervention on bone loss and implant migration.

Twenty-two patients received 90mg of pamidronate and 22 received placebo at randomisation 5 days after surgery. Femoral and pelvic bone mineral density (BMD) was measured by dual energy x-ray absorptiometry (DXA) and implant migration was measured using the EBRA-Digital method over a 104 week period.

In the placebo group rapid periprosthetic bone loss occurred over the first 6 months. After this period a partial recovery in bone mass occurred in most regions. Patients in the pamidronate group had significantly less femoral, but not pelvic, bone loss than those give placebo (ANOVA P=0.02). Pamidronate was most effective in preventing bone loss in Gruen zones 6 and 7 (ANOVA P=0.004, and P=0.014, respectively). At week 104 the mean total stem migration was 1.77mm±0.27 and 1.62mm±0.37 for the placebo and pamidronate groups, respectively (P> 0.05). Total cup migration was 0.75mm±0.26 and 0.76mm±0.14, respectively (P> 0.05). Age at surgery accounted for 26% (linear regression r=−0.65, P=0.02) and 38% (r=−0.51, P=0.007) of the variability in stem and cup migration at week 104, with younger subjects experiencing greater migration. Stem migration at week 104 was also inversely related to the Barrack cement mantle grade (r=−0.66, r2 41%, P=0.0003). Implant migration was not significantly related to changes in periprosthetic bone mass.

Pamidronate therapy has a significant effect on bone mass, but not implant stability, after THA.Our findings suggest that the major determinants of early migration after THA are young patient age and poor cementing technique.


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_II | Pages 151 - 151
1 Jul 2002
Wilkinson JM Stockley I Peel NFA Hamer AJ Barrington NA Eastell R
Full Access

We aimed to determine whether acute periprosthetic bone loss at 1 year following THA may be predicted by early changes in markers of bone turnover, and prevented by a single 90 mg dose of pamidronate in a randomized trial of 46 men and women undergoing primary THA.

Femoral BMD was measured at postoperative baseline, and 6, 12, 26, and 52 weeks later using an Hologic 4500-A densitometer. Markers of bone turnover were measured at preoperative baseline and at 1, 6, 12, and 26 weeks.

Patients in the placebo group lost significantly more periprosthetic bone than those in the pamidronate group. The mean (±95% CI) difference in proximal femoral BMD (area under BMD change.time curve) between those receiving pamidronate and those receiving placebo was 1.84 (±1.29) g.weeks/cm2 (P=0.02). A transient increase in all markers of bone turnover was seen in the placebo group, with peaks in osteoclast activity at 6 weeks, and peaks in osteoblast activity 12 weeks. Pamidronate therapy was associated with suppression of all markers of bone turnover with the exception of the resorption marker iFDpd (P< 0.05).

Using a multiple regression analysis model the AUC changes in bone markers predicted 42% of proximal femoral BMD change at 1 year (P=0.006). Using only change in 2 of the markers (PINP and iFDpd) at 6 weeks 28% of proximal femoral BMD change at 1 year could be predicted (P=0.01).

THA is associated with a transient increase in bone remodelling units and bone loss. The relationship between femoral bone loss and turnover markers in the placebo group suggests that the transient increase in these markers reflects local changes in BMD, and that pamidronate reduces bone loss by preventing increased local bone turnover.


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_II | Pages 152 - 152
1 Jul 2002
Phillips NJ Wilkinson JM Stockley I
Full Access

We aimed to determine whether the EBRA method had greater precision and sensitivity for measuring implant migration following total hip arthroplasty (THA) than direct plain radiographic techniques using modern measuring tools.

Short-term precision was evaluated in 20 subjects following THA. Consecutive, standardised radiographs of the hip were performed on the same day after repositioning. Prosthetic cup and stem migration were measured from the plain radiographs using a digital calliper following methods described by Ianotti, Malchau, Nunn, Sutherland and Wetherall, and compared to those made using EBRA. Precision was expressed as 95% confidence interval (95%CI = 1.96x Std.dev.). 10 subjects were then followed prospectively with standardised plain radiographs at baseline, 6,12 and 26 weeks after THA. Migration measurements made using EBRA were compared to those made using the most precise plain radiographic method.

The 95%CI of all EBRA cup and stem measurements was ±1mm or smaller. Only the Sutherland method had a similar level of precision (95%CI ±1.11 to 1.28 mm: F-Test P> 0.05; all other method comparisons with EBRA P< 0.05). In the longitudinal study cup cranial migration of 0.53 mm (SEM 0.19) and stem subsidence of 1.53 mm (SEM 0.19) were detected using EBRA (2-way ANOVA by rank; P< 0.05 and P< 0.001 respectively). No statistically significant migration of the cup or stem was detected using the Sutherland method.

The EBRA method is a precise method for describing implant migration in small groups of patients in the early period following THA, and manual methods lack sufficient precision to be used for this purpose.


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_II | Pages 152 - 152
1 Jul 2002
Wilkinson JM Stockley I Barrington NA Eastell R
Full Access

We aimed to determine whether development of heterotopic ossification (HO) following THA might be predicted by early changes in biochemical markers of bone turnover.

The study cohort consisted of 21 men and women taking part in a randomised trial of the bisphosphonate pamidronate in the prevention of bone loss following THA. All had under gone unilateral THA using the same design of implant and all were assigned to placebo in the trial. The osteoblast activity markers bone-specific alkaline phosphatase (bAP), osteocalcin (Oc), and N-terminal propeptide of type-I procollagen (PINP); and the osteoclast activity markers deoxypyridinoline (iFDpd) and N-telopeptide of type-I collagen (NTx) were measured at baseline, and at 1, 6, 12, and 26 weeks following unilateral THA. The presence of HO was assessed using the Brooker grading by a musculoskeletal radiologist from plain AP radiographs of the hip taken at week 26.

A transient increase in all turnover markers occurred following surgery, with peaks in iFDpd, NTx, and PINP at 6 weeks, and peaks in bAP and Oc at 12 weeks. 10 subjects had HO at week 26 (all Brooker grade 1 or 2). Subjects with HO had higher mean peak rises (SEM) in PINP and Oc than those without HO (PINP 81% (10) versus 43% (10), P=0.01; Oc 26% (5) versus 9% (6), P=0.04). Using area under the curve ‘ROC’ analysis, PINP and Oc were equally discriminatory in predicting HO formation (P< 0.05). The optimal cut-off peak rise of > 57% in PINP at 6 weeks following THA had a sensitivity and specificity of 90 and 82, respectively for predicting the development of HO.

An increase in PINP of more than 57% 6 weeks following THA is predictive of the development of HO at 26 weeks. This early prediction might allow identification of patients in whom early therapeutic measures could be taken.


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_II | Pages 152 - 152
1 Jul 2002
Taggart T Kerry RM Stockley I Norman P
Full Access

The incidence of infection after primary arthroplasty is low. However, with the increasing number of arthroplasties being performed the prevalence of infection is increasing. The pattern of infecting organisms following total joint arthroplasty has changed and gentamicin resistant organisms are becoming increasingly common. Vancomycin added to bone a cement carrier can, with adequate surgical debridement be very effective in the eradication of established resistant infection. We report the results of its use in 33 patients with 26 infected hip and 7 infected knee arthroplasies. 32 patients remain clinically and radiologically free of infection after a mean follow-up of 67 months. There was one recurrence of infection and there were three positive second stage cultures of uncertain significance. Vancomycin is potentially a very useful tool in the management of deep infection following arthroplasty surgery.


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_II | Pages 154 - 154
1 Jul 2002
Graham NM Stockley I
Full Access

In Sheffield the senior author has a long experience in the use of massive circumferential proximal femoral allografts in complex revision hip arthroplasty. Sheffield has a well established bone harvesting and banking service, essential for this type of work.

We wish to present the early experience with this technique in the UK.

Between April 1992 and November 1998 a total of 33 circumferential proximal femoral allografts were used by one senior surgeon. They were all fresh frozen, cadaveric grafts. This time period was selected to allow a reasonable minimum follow-up period. Seven patients had died and two were lost to follow up, leaving a total of 24 patients to review.

A step cut osteotomy was utilised and augmented with a cerclage wire and strut allograft where deemed necessary. The proximal femur was retained where possible. The component was cemented into the allograft only, in the majority of the cases. A cemented, collared prosthesis was used in over 85% of cases.

Average follow up was 53 months. By the time of review 2 had undergone further revision, one for sepsis, one for aseptic loosening. A further patient had had revision of the acetabular component in isolation. One patient had recurrent sepsis but is currently being managed non–operatively. One patient required secondary surgery with plate and graft for symptomatic junctional non-union.

Other complications included wound drainage, delaying discharge, in three patients and one chronic sciatic nerve palsy.

The trochanter was considered radiologically united in 18 patients. Junctional union was considered to have occurred in 17 patients. Allograft resorption of 100% cortical thickness was seen in only 9 patients and in only one zone in 6 of these.

Oxford hip scores were collected at follow-up.

We recommend this technique in cases where bone loss is catastrophic and in specialist hands only.


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 1 | Pages 70 - 72
1 Jan 2002
Taggart T Kerry RM Norman P Stockley I

Although the incidence of infection associated with hip and knee prostheses is low, with the increasing number of arthroplasties being carried out, the total number of such cases is increasing. The pattern of infecting organisms after total joint arthroplasty has changed and gentamicin-resistant organisms are becoming increasingly common. In conjunction with surgical debridement, vancomycin added to a bone-cement carrier can be very effective in the treatment of infection caused by such organisms.

We report the results of its use in proven deep infection in 26 hip and seven knee arthroplasties. After a mean follow-up of 67 months, 32 patients remained clinically and radiologically free from infection. There was one recurrence and positive second-stage cultures of uncertain significance in three other patients. Vancomycin is potentially very useful in the management of deep infection after arthroplasty.


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 2 | Pages 283 - 288
1 Mar 2001
Wilkinson JM Peel NFA Elson RA Stockley I Eastell R

We aimed to evaluate the precision and longitudinal sensitivity of measurement of bone mineral density (BMD) in the pelvis and to determine the effect of bone cement on the measurement of BMD in femoral regions of interest (ROI) after total hip arthroplasty (THA).

A series of 29 patients had duplicate dual-energy x-ray absorptiometry (DXA) scans of the hip within 13 months of THA. Pelvic analyses using 3- and 4-ROI models gave a coefficient of variation (CV) of 2.5% to 3.6% and of 2.5% to 4.8%, respectively. Repeat scans in 17 subjects one year later showed a significant change in BMD in three regions using the 4-ROI model, compared with change in only one region with the 3-ROI model (p < 0.05).

Manual exclusion of cement from femoral ROIs increased the net CV from 1.6% to 3.6% (p = 0.001), and decreased the measured BMD by 20% (t = 12.1, p < 0.001). Studies of two cement phantoms in vitro showed a small downward drift in bone cement BMD giving a measurement error of less than 0.03 g/cm2/year associated with inclusion of cement in femoral ROIs.

Changes in pelvic periprosthetic BMD are best detected using a 4-ROI model. Analysis of femoral ROI is more precise without exclusion of cement although an awareness of its effect on the measurement of the BMD is needed.


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 2 | Pages 183 - 184
1 Mar 2001
Bruce ASW Kerry RM Norman P Stockley I

We report two cases of fungal infection of prosthetic joints which were successfully treated by the incorporation of fluconazole into polymethylmethacrylate beads inserted at the time of debridement.


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 2 | Pages 342 - 344
1 Mar 1999
Hamer AJ Stockley I Elson RA

Secondary sterilisation of allograft bone by gamma irradiation is common, but the conditions under which it is performed vary between tissue banks. Some do so at room temperature, others while the bone is frozen. Bone is made brittle by irradiation because of the destruction of collagen alpha chains, probably mediated by free radicals generated from water molecules. Freezing reduces the mobility of water molecules and may therefore decrease the production of free radicals. We found that bone irradiated at −78°C was less brittle and had less collagen damage than when irradiated at room temperature. These findings may have implications for bone-banking.


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 3 | Pages 363 - 368
1 May 1996
Hamer AJ Strachan JR Black MM Ibbotson CJ Stockley I Elson RA

There have been conflicting reports on the effects of gamma irradiation on the material properties of cortical allograft bone. To investigate changes which result from the method of preparation, test samples must be produced with similar mechanical properties to minimise variations other than those resulting from treatment.

We describe a new method for the comparative measurement of bone strength using standard bone samples. We used 233 samples from six cadavers to study the effects of irradiation at a standard dose (28 kGy) alone and combined with deep freezing. We also investigated the effects of varying the dose from 6.8 to 60 kGy (n = 132).

None of the treatments had any effect on the elastic behaviour of the samples, but there was a reduction in strength to 64% of control values (p < 0.01) after irradiation with 28 kGy. There was also a dose-dependent reduction in strength and in the ability of the samples to absorb work before failure

We suggest that irradiation may cause an alteration in the bone matrix of allograft bone, but provided it is used in situations in which loading is within its elastic region, then failure should not occur.


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 1 | Pages 28 - 31
1 Jan 1993
Scott I Stockley I Getty C

We report a series of 17 exchange arthroplasties for infected knee prostheses, ten one-stage and seven two-stage procedures. The method proved successful in controlling infection and restoring function. In two-stage exchanges the interval between the stages was managed by using a prosthesis as a spacer, and acrylic cement beads containing the appropriate antibiotic to provide high local concentrations. Three one-stage procedures had recurrence of infection, but were successfully treated by further exchange operations. All patients had satisfactory function and there have been no serious complications. We recommend this modified two-stage technique for the management of infected knee arthroplasties.


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 3 | Pages 393 - 397
1 May 1992
Stockley I McAuley J Gross A

We reviewed 32 deep-frozen irradiated allografts used for the reconstruction of bone defects in 20 knees. They were subdivided into bulk grafts, cortical strut grafts, and morsellised bone. The average follow-up was 4.2 years (2 to 7.2). Radiographs showed union of the allograft to the host in all cases. Two allografts later fractured and three knees required further surgery because of infection. The allografts effectively filled large bone defects around the knee, lessening the need for custom-made and constrained prostheses.


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 6 | Pages 1073 - 1075
1 Nov 1990
Fern E Stockley I Bell M

Five patients with Boyd type II congenital pseudarthrosis of the tibia underwent excision of the pseudarthrosis and double onlay bone grafting. Stability was maintained by extending intramedullary rods. Clinical union was achieved in all cases at a mean of 8.6 months (range six to 11). The rods extended by 15.7% (range 2% to 31.4%) as growth occurred. One rod was removed because of infection and a vascularised free fibular graft was subsequently performed. The extending rods provided stability while union occurred and did not require revision as the legs grew. The rods can be removed easily and have not jeopardized further surgical options.


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 5 | Pages 772 - 774
1 Sep 1990
Stanley D Stockley I Getty C

In a prospective study of 100 knee arthroplasties in patients with rheumatoid arthritis, simultaneous bilateral surgery was compared with staged bilateral replacements. All patients had improved function following their operations but those who had staged surgery only achieved maximum benefit after the second knee had been replaced. The complication rate was no greater for simultaneous surgery and we therefore advocate the method for those patients who require bilateral replacements.


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 4 | Pages 705 - 708
1 Jul 1990
Stockley I Betts R Rowley D Getty C Duckworth T

The relationship between hindfoot deformity and forefoot pressure was assessed in 28 rheumatoid patients who had undergone forefoot reconstruction four years previously. Patients with valgus hindfoot deformities tended to have high forefoot pressures whereas those with a normal hindfoot recorded normal pressures on the dynamic pedobarograph. All patients with residual forefoot pain recorded abnormal forefoot pressures. We believe that orthotic control of hindfoot deformities should be considered for those patients who require forefoot surgery as a combination of surgical and orthotic management may offer the best chance of success.


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 3 | Pages 422 - 427
1 May 1989
Stockley I Bell M Sharrard W

We report the results of using 83 expanding intramedullary rods in 24 children with osteogenesis imperfecta after a mean follow-up of five years three months. In all, 62% of the rods have expanded after one primary operation. Thirty-four additional operations were necessary; 11 for the correction of rotation or angulation deformities and 23 for revision of the rod or T-piece. All these revisions were successful. Complications were more frequent in children who required very small rods. Problems with Bailey-Dubow rods led to the development of the Sheffield rod system; 17 bones treated with these rods are included in the series. Before surgery only eight of the 24 children were able to walk but at review 20 children were walking, 15 without walking aids. Elongating intramedullary rods should be available to all children with osteogenesis imperfecta as they improve walking capability, reduce the number of fractures, prevent deformity and allow integration of the child into society.


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 2 | Pages 329 - 330
1 Mar 1988
Stockley I Bickerstaff D