The cemented mobile bearing metal backed low contact stress patellofemoral arthroplasty (LCS PFA) is a newer design belonging to the second generation of inlay type implant, based on the more successful knee arthroplasty model. The advantage is the patella can articulate with the trochlear implant as well as the femoral component of a total knee replacement (TKR). This series is a cohort of 21 patients who underwent 24 (3 bilateral) unicompartmental PFA replacements for isolated patellofemoral osteoarthritis. We have used the mobile bearing LCS PFA in all of them. There were 3 males and 18 females. Average age was 51(40-58) years. The Oxford Knee score was used to assess the results.Background
Patients
Shockwave therapy has been shown to induce osteoneogenesis in animal models. The mechanism of action is unclear, but experimental evidence suggests micro-fracture formation and increased blood flow as the most likely explanation. Several reports from Europe have suggested good results from the treatment of delayed fracture union with shock-waves. We present the results of a randomised double-blind placebo-controlled pilot study. Fourteen patients with clinically and radiologically confirmed delayed union of long-bones consented to enter the trial. The treatment group had a single application of 3000 high-energy shockwaves using the Stortz SLK unit with image intensifier control. The control group had the exactly the same treatment but with an ‘air-gap’ interposition to create a placebo-shockwave. Each patient was followed-up with serial radiographs as well as visual analogue pain scores and EuroQol assessments. All of the patients were reviewed for a minimum of three years post treatment.Background
Method
Printed plain radiographs have traditionally been the method of image transfer between hospitals, but the advent of digital imaging has revolutionised modern day radiology. It is now commonplace for compact discs to be used as the transport media for digital images, the theoretical advantages being ease of transport and storage, integration with PACS systems and the ability to perform image manipulation. However, in our tertiary referral centre for pelvic and acetabular trauma, we noted problems with digital image transfer using this method. We examined the last 25 compact discs sent to our unit for functionality on 3 separate computers. Only 17/25 discs loaded on all computers, and 2 discs failed to load on any computer. 9 of the remaining 23 discs did not allow image manipulation, and 1 disc would not allow retrieval of all the contained images. 5 of the 23 discs took longer than 5 minutes to retrieve the contained images. In summary, we classed 10 of the 25 discs as acceptable. Patient transfer to our unit was not delayed, but 4 patients underwent repeat CT scans due to incomplete imaging Digital technology has made great advances into medical imaging. Standardisation using the DICOM format for image creation has attempted to eliminate issues of compatibility, but variation in software used to produce and view images can still vary from these standards. Technical errors in the creation of discs should be eliminated at source, and it is mandatory that referring units check the functionality of discs before they are sent. In this way, the potential for delay to transfer and subsequent repeat exposure to ionising radiation can be avoided.
Our aim was to analyse radiological outcome of proximal humerus fractures treated with Philos plate and to assess its usefulness in treatment of malunion and non-union. Seventy-seven patients were treated with Philos plate (24 men and 53 women). Mean age was 61 years (15–88). There were 66 acute fractures, 6 nonunion, 4 mal-union and one periprosthetic fracture. Acute fractures included 29 two part, 30 three part and five 4 part fractures. Seven had associated dislocation. There were two head splitting fractures. Deltopectoral approach was used in all. No acute fractures were bonegrafted however all nonunions had bonegraft. Postoperative radiographs were available for review for 59. Average union time was 12 weeks (8–24). Satisfactory union occurred in 51 (86.4%). Twenty-three (39 %) fractures had inadequate reduction. Malplacement of plate was observed in 25 (42%) leading to significant malunion in 11.8%. Satisfactory union was occurred in all of last 30 patients. Nonunion occurred in 2 with infection in one. Other complications included screw penetration into glenohumeral joint, avascular necrosis, screw backing out and tuberosity detachment. Philos plate fixation was used for treatment of 6 nonunions, 4 malunions and one periprosthetic fracture with satisfactory outcome in all. Relatively high rate of complications was observed in early cases in this series. This could be attributed to the steep learning curve with this technique. Emphasis should be put on careful and adequate reduction of fracture and optimal placement of plate (about 8 mm from the tip of tuberosity) to avoid impingement and to achieve correct screw placement in the humeral head. In conclusion, Philos plate has been of benefit in management of complex fractures as well as management of non-union of proximal humerus. Quality of reduction and optimal placement of plate appear to be the two most important parameters for a successful outcome.
As part of the workup long length femur radiograph may be carried out pre-operatively in patients presenting with a proximal femur fracture in order to rule out distant metastasis in patients with a history of malignancy but also in some patients in whom a suspicion of possible distal abnormality is aroused by the configuration of the proximal fracture Using our unit’s database we identified all patients (n=689) presenting with a proximal femoral fracture between Sept 2006 and August 2007 at the Norfolk and Norwich University hospital in Norwich. Of 689 patients, 92 patients (13.2%) had long length femur radiograph performed before surgery. Indications included history of cancer (39), subtrochantric fractures (14), spontaneous fracture without any fall(2), paget s disease(1), early onset osteoporosis(1) while no clear indication was available in 35 patients. Five patients (5.5%) were found to have some abnormality. Three of the 39 patients with a history of previous cancer were found to have a distal femur metastasis. Two of the 35 patients where a clear indication was not apparent had abnormal findings: one patient had a distal femur infarction and another was found to have a distal femoral malunion. In both cases long leg films did not influence choice of implant. Of the 39 patients with a previous history of cancer, 24 had short implants (hemi-arthroplasty, intramedullary device, DHS), 14 had long implants and one patient died before the operation. Long length femoral radiographs appear to be indicated in patients with a documented history of a cancer as it helps to decide whether to use a long or short implant. However in patients without a history of malignancy, long leg films were of no value in decision making even if the configuration of the fracture was suspicious.
Compared with general anaesthesia, brachial plexus (BP) anaesthesia improves patient satisfaction and accelerates hospital discharge after ambulatory hand surgery; however, variable success rates and typical onset times up to 30 minutes have limited its widespread use. Increasing availability of high-resolution portable ultrasound has renewed interest in more proximal approaches to the BP, previously thought to carry unacceptable risk. The aim of this study was to compare the onset times of ultrasound guided supraclavicular and infraclavicular BP block in patients undergoing ambulatory hand surgery. With ethics committee approval, patients presenting for hand surgery were prospectively randomised to either supraclavicular (trunks/divisions) or infraclavicular (cords) BP block. A single experienced operator (MF) placed all blocks using ultrasound only guidance. A blinded observer (AP, SY) assessed pinprick sensory and motor block on 3-point scale (normal=2, reduced=1, absent=0) in the median, ulnar, radial and musculocutaneous nerve territories every five minutes, or until blocks were complete. A single general anaesthesia without influence from the unblended anaesthetist. Of the first 27 patients recruited, block placement details and Intraoperative data are presented in There was a trend to faster onset times and higher success in group infraclavicular, however, this did not reach statistical significance. Interim results are so far inconclusive for the superiority of one approach. Both techniques were well tolerated and had a high success rate for surgical anaesthesia.
Methicillin-resistant Staphylococcus aureus (MRSA) has become a ubiquitous bacterium in both the hospital and community setting. There are two major subclassifications of MRSA, community-acquired and healthcare-acquired, each with differing pathogenicity and management. MRSA is increasingly responsible for infections in otherwise healthy, active adults. Local outbreaks affect both professional and amateur athletes and there is increasing public awareness of the issue. Health-acquired MRSA has major cost and outcome implications for patients and hospitals. The increasing prevalence and severity of MRSA means that the orthopaedic community should have a basic knowledge of the bacterium, its presentation and options for treatment. This paper examines the evolution of MRSA, analyses the spectrum of diseases produced by this bacterium and presents current prevention and treatment strategies for orthopaedic infections from MRSA.
Iliacus haematoma is a relatively rare condition, which may cause a local compressive neuropathy. It is usually diagnosed in adults with haemophilia or those on anticoagulation treatment and may occur after trauma. We present the case of a healthy 15-year-old boy with a femoral neuropathy due to an iliacus haematoma which resolved following conservative treatment.
The authors would like to present a retrospective study conducted on 178 patients having undergone a hip replacement. The aim of this study was to look at the immediate and short-term complications of hip replacement in relation to the body mass index (BMI). Patients ranging from age 49 to 90 were included in this study with an average age of 67.5. BMI ranged from 18 to 41. Length of stay ranged from 3 days to 76 days with an average of 11.5 days. Follow up of each patient included any wound complications, time to mobilisation and time to discharge. Operative blood loss and need to transfusion were also looked at. Blood loss was found to be from 150 mls to 2400 mls. A large number of orthopaedic surgeons use a BMI value of 35 as the upper cut off point to refuse elective surgery. Using the Null hypothesis the authors wanted to prove that a higher BMI resulted in higher complication rates. Statistical analysis of the data however did not show a significant relationship between BMI and early complications in hip replacement surgery. Parameters measured had a higher relationship to individual surgeons rather than the BMI. The authors would like to conclude that using the BMI as a predictor of a higher rate of short-term complications and refusing surgery to patients with a higher BMI is not justified.
We have prospectively compared the fixation of 100 intertrochanteric fractures of the proximal femur in elderly patients with random use of either a Dynamic Hip Screw (DHS) or a new intramedullary device, the Gamma nail. We found no difference in operating time, blood loss, wound complications, stay in hospital, place of eventual discharge, or the patients' mobility at final review. There was no difference in failure of proximal fixation: cut-out occurred in three cases with the DHS, and twice with the Gamma nail. However, in four cases fracture of the femur occurred close to the Gamma nail, requiring further major surgery. In the absence of these complications, union was seen by six months in both groups.
We report three patients in whom a fractured odontoid process was associated with a fracture of the superior articular process of the second cervical vertebra. Although there were no signs of neurological disorder, damage to the C1-C2 joint in all three patients made fusion necessary. Forced lateral flexion is suggested as the possible mechanism of injury.