header advert
Results 21 - 26 of 26
Results per page:
Applied filters
General Orthopaedics

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 257 - 257
1 Mar 2013
Matsuzaki T Matsumoto T Kubo S Muratsu H Matsushita T Oka S Nagai K Kurosaka M Kuroda R
Full Access

Introduction

Appropriate intraoperative soft tissue balancing is recognized to be essential in total knee arthroplasty (TKA). However, it has been rarely reported whether intraoperative soft tissue balance reflects postoperative outcomes. In this study, we therefore assessed the relationship between the intra-operative soft tissue balance measurements and the post-operative stress radiographs at a minimum 1-year follow-up in cruciate-retaining (CR) TKA, and further analyzed the postoperative clinical outcome.

Methods

The subjects were 25 patients diagnosed with osteoarthritis with varus deformity and underwent primary TKA. The mean age at surgery was 72.0 ± 7.5 years (range, 47–84 years). The Surgeries were performed with the tibia first gap technique using CR-TKA (e motion, B. Braun Aesculap) and the image-free navigation system (Orthopilot). We intraoperatively measured varus ligament balance (°, varus angle; VA) and joint component gap (mm, center gap; CG) at 10° and 90° knee flexion guided by the navigation system, with the patella reduced. At a minimum 1-year follow-up, post-operative coronal laxity at extension was assessed by varus and valgus stress radiographs of the knees with 1.5 kgf using a Telos SE arthrometer (Fa Telos) and that at flexion was assessed by epicondylar view radiographs of the knees with a 1.5-kg weight at the ankle. After calculating postoperative VA and CG from measurements of radiographs, measurements and preoperative and postoperative clinical outcome, such as Knee Society Clinical Rating System (Knee score; KSS, Functional score; KSFS) and postoperative knee flexion, were analyzed statistically using linear regression models and Pearson's correlation coefficient.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 217 - 217
1 Mar 2013
Kihara S Muratsu H Matsumoto T Kirizuki S Maruo A Miya H Kuroda R Kurosaka M
Full Access

Introduction

Rapid increase of aged population has been one of major issue affecting national health care plan in Japan. In 2006, Japanese Orthopaedic Association proposed the clinical entity of musculoskeletal ambulation disorder symptom complex (MADS) to define the elderly population with high risk of fall and ambulatory disability caused by musculoskeletal disorders. Osteoarthritis of the knee is one of major cause of MADS. The number of patients with MADS underwent total knee arthroplasty (TKA) had been increased in Japan, and also expected to increase worldwide in the near future. The effectiveness of TKA for the patient with MADS has not been well evaluated. In the present study, we analyzed the early post-operative functional recovery after TKA using 2 simple performance tests to diagnose MADS.

Material & Method

Fifty patients with varus type osteoarthritic knees implanted with posterior-stabilized (PS) TKAs were subjected to this study. There were 44 female and 6 male patients. The mean age of the patients was 71.6 years (range, 59 to 84 years). Patients were subjected to 2 functional performance tests which were essential tests for MADS diagnosis. Firstly, 3 meter timed up and go test (TUG) was used to evaluate ambulation. Secondary one leg standing time with open eyes was measured to assess balancing ability. 2 tests were performed pre-operatively, 2 weeks after surgery and at discharge (23.8 days po). MADS was defined to be diagnosed if TUG and one leg standing time was not less than 11 seconds and/or less than 15 seconds respectively. Each parameter was compared among at above mentioned three time points -using a repeated measured analysis of variance (p<0.05).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XL | Pages 183 - 183
1 Sep 2012
Takahara S Muratsu H Nagai K Matsumoto T Kubo S Maruo A Miya H Kuroda R Kurosaka M
Full Access

Objective

Although both accurate component placement and adequate soft tissue balance have been recognized as essential surgical principle in total knee arthroplasty (TKA), the influence of intra-operative soft tissue balance on the post-operative clinical results has not been well investigated. In the present study, newly developed TKA tensor was used to evaluate soft tissue balance quantitatively. We analyzed the influence of soft tissue balance on the post-operative knee extension after posterior-stabilized (PS) TKA.

Materials and Methods

Fifty varus type osteoarthritic knees implanted with PS-TKAs were subjected to this study. All TKAs were performed using measured resection technique with anterior reference method. The thickness of resected bone fragments was measured.

Following each bony resection and soft tissue releases, we measured soft tissue balance at extension and flexion of the knee using a newly developed offset type tensor. This tensor device enabled quantitative soft tissue balance measurement with femoral trial component in place and patello-femoral (PF) joint repaired (component gap evaluation) in addition to the conventional measurement between osteotomized surfaces (osteotomy gap evaluation). Soft tissue balance was evaluated by the center gap (mm) and ligament balance (°; positive in varus) applying joint distraction forces at 40 lbs (178 N).

Active knee extension in spine position was measured by lateral X-ray at 4 weeks post-operatively. The effect of each parameter (soft tissue balance evaluations, thickness of polyethylene insert and resected bone) on the post-operative knee extension was evaluated using simple linear regression analysis. P<0.05 was considered statistically significant.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XL | Pages 129 - 129
1 Sep 2012
Oka S Matsumoto T Kubo S Muratsu H Sasaki H Matsushita T Kuroda R Kurosaka M
Full Access

Introductions

In cruciate-retaining total knee arthroplasty (TKA), among many factors influencing post-operative outcome, increasing the tibial slope has been considered as one of the beneficial factors to gain deep flexion because of leading more consistent femoral rollback and avoiding direct impingement of the insert against the posterior femur. In contrast, whether increasing the tibial slope is useful or not is controversial in posterior-stabilized (PS) TKA, Under such recognition, accurate soft tissue balancing is also essential surgical intervention for acquisition of successful postoperative outcomes in TKA. In order to permit soft tissue balancing under more physiological conditions during TKAs, we developed an offset type tensor to obtain soft tissue balancing throughout the range of motion with reduced patello-femoral(PF) and aligned tibiofemoral joints and have reported the relationship between intra-operative soft tissue balance and flexion angles. In this study, we therefore assessed the relationship between intra-operative soft tissue balance assessed using the tensor and the tibial slope in PS TKA.

Materials and methods

Thirty patients aged with a mean 72.6 years were operated PS TKA(NexGen LPS-Flex, Zimmer, Inc. Warsaw, IN) for the varus type osteoarthritis. Following each bony resection and soft tissue release using measure resection technique, the tensor was fixed to the proximal tibia and femoral trial prosthesis was fitted. Assessment of the joint component gap (mm) and the ligament balance in varus (°)was carried out at 0, 10, 45, 90and 135degrees of knee flexion. The joint distraction force was set at 40lbs. Joint component gap change values during 10-0°,45-0°, 90-0°, 135-0° flexion angle were also calculated. The tibial slopes were measured by postoperative lateral radiograph. The correlation between the tibial slope and values of soft tissue balance were assessed using linear regression analysis.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 121 - 121
1 Jun 2012
Kubo S Sasaki H Matsumoto T Muratsu H Ishida K Takayama K Oka S Tei K Sasaki K Kuroda R
Full Access

Introduction

Accurate soft tissue balancing has been recognized as important as alignment of bony cut in total knee arthroplasty (TKA). In addition, using a tensor for TKA that is designed to facilitate soft tissue balance measurements throughout the range of motion with a reduced patello-femoral (PF) joint and femoral component in place, PF joint condition (everted or reduced) has been proved to have a significant effect for intra-operative soft tissue balance. On the other hand, effect of patellar height on intra-operative soft tissue balance has not been well addressed. Therefore, in the present study, we investigated the effect of patellar height by comparing intra-operative soft tissue balance of patella higher subjects (Insall-Salvati index>1) and patella lower subjects (Insall-Salvati indexâ‰/1).

Materials and methods

The subjects were 30 consecutive patients (2 men, 28 women), who underwent primary PS TKA (NexGen LPS-flex PS: Zimmer, Warsaw, IN, USA) between May 2003 and December 2006. All cases were osteoarthritis with varus deformity. Preoperative Insall-Salvati index (ISI) was measured and patients were divided into two groups; the patella higher group (ISIï1/4ž1: 18 knees average ISI was 1.12) and the patella lower group (ISIâ‰/1; 12 knees average ISI was 0.94). Component gap and ligament balance (varus angle) were measured using offset-type tensor with 40lb distraction force after osteotomy with the PF joint reduced and femoral trial in place at 0, 10, 45, 90, 135 degrees of knee flexion. Data of two groups were compared using unpaired t test.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 143 - 143
1 Jun 2012
Matsumoto T Kubo S Muratsu H Ishida K Takayama K Matsushita T Tei K Kurosaka M Kuroda R
Full Access

Using a tensor for total knee arthroplasty (TKA) that is designed to facilitate soft tissue balance measurements with a reduced patello-femoral (PF) joint, we examined the influence of pre-operative deformity on intra-operative soft tissue balance during posterior-stabilized (PS) TKA. Joint component gap and varus angle were assessed at 0, 10, 45, 90 and 135° of flexion with femoral trial prosthesis placed and PF joint reduced in 60 varus type osteoarthritic patients. Joint gap measurement showed no significant difference regardless the amount of pre-operative varus alignment. With the procedures of soft tissue release avoiding joint line elevation, however, intra-operative varus angle with varus alignment of more than 20 degrees exhibited significant larger values compared to those with varus alignment of less than 20 degrees throughout the range of motion. Accordingly, we conclude that pre-operative severe varus deformity may have the risk for leaving post-operative varus soft tissue balance during PS TKA.