To investigate the amount and the factors of changes of the thickness of tibial polyethylene insert in revisional TKA compared to original thickness of primary TKA. We analyzed one hundred and twenty cases of wear, loosening and instability were included in this study. Infection cases were excluded. The period between the primary TKA and revision TKA was 88.5 months in average (range 1 to 17 year 3 months). The amount of increase of the tibial polyethylene thickness according to the main cause of failure and the wear site was analyzed. The results of this study were: 1: The increased thickness was 6.7 mm in average. 2: The amount of increase in case of wear of anterior portion only was 2.3 mm, which was below the average. 3: The loosening cases showed 8.2 mm increase in average which was significantly greater than the average. 4: The cases of greater wear of medial side than lateral side showed 8.5 mm increase of the thickness which was significantly greater than the average. 5: The cases of only medial side wear showed 5.5 mm increase of the thickness, which was below the average. 6: The cases of the other causes such as patellar component wear, generalized wear, wear of posterior portion only, early wear less than 5 years after primary TKA because of flat polyethylene surface showed comparable amount of wear to the average. The thickness of tibial polyethylene insert in revisional TKA compare to original thickness of primary TKA showed that it increased 6.7mm in average and was variable according to the cause of failure.
To analyze the mechanism of failure and basic cause in cases of early failure which were required revision within 5 years index TKA. Between 1991 and 2006, 167 revisions TKA of aseptic failure were performed. Revision diagnosis or reason for failure were categorized as wear of tibial polyethylene insert, failure of tibial base plate, early imbalance between medial and lateral soft tension, tight or loose PCL and posterior capsule. The percentages of each failure category were calculated as a percentage of the overall number of revision TKA and a percentage of the early failures. A descriptive statistics were calculated for the time in situ for each failure category. Early failure within 5 years following index TKA occurred in 33 out of 167 TKA(20.0%). Average time in situ was 38.53 months(3.21 years). Wear of the tibial polyethylene insert occurred in 12 out of 33 cases(36.4%). All cases showed tight PCL. Loosening was the second leading cause occurring in 9 cases(27.2%). Pure instability with tight MCL occurred in 3 knees. Catastrophic early wear within one year after index surgery occurred in 18 knees. The cause of failure were flat surfaced poly in 11, fracture of metal tray 2, dislocation of the thick poly insert 1 and early poly wear due to unknown cause 4. There were multiple factors of the early failure, which could be divided into design failure and surgical skill failure. However, they worked together in most of the cases.
Beta–tricalciumphosphate(β-TCP)coatinglayerisknown to be resorbed much faster than hydroxyapatite(HA), however, there has been few reports explaining the exact mechanism until now. Therefore, we investigated whether the resorption mechanisms of these two compounds are same, if not, what is the difference. Eighty titanium discs with 12mm in diameter and 2mm in thickness were coated with HA(n=40) or β-TCP(n=40) by dip and spin coating method. In each group, the specimens were divided into 2 subgroups respectively; Dissolution (D, n=20) group and Osteoclast culture (C, n=20) group. The coated discs in D group were immersed in the cell culture media for 5 days, whereas, in C group, osteoclast-like cells (5×103 cells/500μ), which were isolated form human giant cell tumor, were seeded on the specimens and cultured for 5 days. Cultured cells were defined as osteoclast by the determination of osteoclast marker (tartrate-resistant acid phosphatase, TRAP). After immersion or osteoclast culture, the dissolution characteristics of coating surface were observed using light microscope (LM) and scanning electron microscope (SEM). And the area fraction of resorption lacunae formed by osteoclast was analyzed by image analysis to evaluate the activity of osteoclastic degradation. After 5 days of dissolution, there were much more cracks and denuded areas in β-TCP coating compared to HA coating. In C group, the osteoclasts covering the coating layer were identified on LM and SEM images. Mean area fraction of resorption lacunae in HA-C group was 11.62%, which was significantly higher than that of 0.73% of β-TCP-C group (p=0.001). We conclude that the resorption mechanism of HA and β-TCP coating layers was different each other in vitro study. The coated β-TCP was degraded mainly by dissolution and also tended to be separated from implant, on the other hand, the HA coating layer was resorbed by osteoclastic activity
We carried out a prospective study to assess the clinical outcome, complications and survival of the NexGen Legacy posterior-stabilised-Flex total knee replacement (TKR) in a consecutive series of 278 knees between May 2003 and February 2005. Mean follow-up for 259 TKRs (98.2%) was 3.8 years (3.0 to 4.8). Annual follow-up showed improvement in the Knee Society scores (paired This relatively large study indicates that the legacy posterior stabilised-Flex design provides excellent short-term outcome but warrants ongoing evaluation to confirm the long-term durability and functioning of the implant.
We present the operative technique and clinical results of concomitant reconstruction of the medial collateral ligament (MCL) and the posterior oblique ligament for medial instability of the knee using autogenous semitendinosus tendon with preservation of the tibial attachment. The semitendinosus tendon graft between the screw on the medial epicondyle and the tibial attachment of the graft was overlapped by the MCL, while the graft between the screw and the insertion of the direct head of the semimembranosus tendon was overlapped by the central arm of the posterior oblique ligament. Assessment was by stress radiograph and the Lysholm knee scoring scale. After a mean follow-up of 52.6 months (25 to 92), the medial joint opening of the knee was within 2 mm in 22 of 24 patients. The mean Lysholm score was 91.9 (80 to 100). Concomitant reconstruction of the MCL and posterior oblique ligament using autogenous semitendinosus tendon provides a good solution to medial instability.
We studied 11 patients with checkrein deformities of the hallux who underwent surgical treatment. Six had lengthening of the flexor hallucis longus tendon by Z-plasty in the midfoot, and five underwent release of adhesions and lengthening of the tendon by Z-plasty at the musculotendinous junction at the fracture site. All six patients who underwent Z-plasty at the midfoot showed complete correction of the deformity without recurrence. Of the five who had release of adhesions and Z-plasty of the tendon at the fracture site, two showed partial and one showed complete recurrence.
We report a case of bifocal rhabdomyosarcoma involving the hand and thigh in an 11-year-old female. We highlight the importance of a thorough clinical examination and an aggressive surgical approach in which each lesion is treated as a separate primary.
We reviewed our experience with a modified triple innominate osteotomy for hip instability and limb shortening due to poliomyelitis in 62 adolescent and adult patients, treated from 1973 to 1990. Their ages at surgery ranged from 12 years to 35 years (average 22.3). At a mean follow-up of 4 years (2 to 18) 59 of the patients (95.2%) had substantial improvement in hip stability, and all but one had radiological improvement as determined by the acetabular angle, centre-edge angle and acetabulum-head quotient. In 59 cases in which transiliac limb lengthening was attempted, the mean gain was 1.7 cm (0.6 to 3.0). When the abductor muscles had been partially paralysed, the operation produced an appreciable increase in power in 12 of the 39 hips examined.
We investigated the effect of bone lengthening by callotasis on longitudinal growth of the tibia in rabbits. Ninety-nine five-week-old immature rabbits were divided into five groups according to the percentage of lengthening: group I, 10%; group II, 20%; group III, 30%; group IV, 40%; and group V, sham operation without lengthening. Corticotomy was performed at the proximal metaphysis of the left tibia and the right tibia was used as a control. The lengthening rate was 0.25 mm twice daily. Radiological, histomorphometric, and immunohistochemical studies were done on animals killed at the time of corticotomy, at the completion of lengthening, and thereafter every two weeks until 12 weeks. Tibial lengthening did not cause retardation of growth when the bone was lengthened by up to 20%. When the bone was lengthened by 30% or more, growth retardation was evident, and persisted until skeletal maturity.