header advert
Results 21 - 40 of 101
Results per page:
Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_5 | Pages 40 - 40
1 Feb 2016
Jenny J Diesinger Y de Gori M
Full Access

Introduction

An appropriate positioning of a total knee replacement (TKR) is a prerequisite for a good functional outcome and a prolonged survival. Navigation systems may facilitate this proper positioning. Patient specific templates have been developed to achieve at least the same accuracy than conventional instruments at a lower cost. We hypothesised that there was no learning curve at our academic department when using patient specific templates for TKR instead of the routinely used navigation system.

Material

The first 20 patients operated on for TKR at our academic department using a patient specific template entered the study. All patients had a pre-operative CT-scan planning with a dedicated software.

The patient specific templates were positioned on the bone according to the best fit technique. The position of the templates was controlled at each step of the procedure by the navigation system, and eventually corrected to achieve the expected goal. The discrepancy between the initial and the final positioning was recorded. The paired difference between each set of measurement was analysed with appropriate statistical tests at a 0.05 level of significance.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_1 | Pages 145 - 145
1 Jan 2016
Galasso O De Gori M Russo R Gasparini G
Full Access

High-dose antibiotic-loaded acrylic cement (ALAC) is used for managing periprosthetic joint infections (PJIs). The marked increase in resistant high-virulence bacteria is drawing the attention of physicians towards alternative antimicrobial formulations to the routinely used antibiotics. To date, few studies simultaneously investigated the elution properties of a broad range of antibiotics. The aim of thepresent in-vitrostudy was to determine the elution kinetics of 14 different high-dose ALACs.

All the ALAC samples showed a burst release of antibiotics in the first hour, progressively decreasing overtime, and elution curves strictly adhered to a non-linear regression analysis formula. Among aminoglycosides, commonly addressed as the most appropriate antibiotics to be loaded into the bone cement, the highest elution rate was that of tobramycin. Among the glycopeptides, commonly used to treat PJIs because of the prevalence of aminoglycoside resistance, vancomycin showed better elution in comparison with teicoplanin. Clindamycin, that can be associated with aminoglycosides to prepare ALACsshowed the highest absolute and relative elutions among all the tested formulations. A noticeable elution was also detected for colistin, an antibiotic of last resort for treating multi-drug resistant bacteria.

The current study demonstrates theoretical advantages in the preparation of ALAC for some antibiotics notroutinely used in the clinical setting for PJIs. The use of these antibiotics based on the infecting bacteria sensitivity may represent an useful option for physicians to eradicate PJIs. In vivo testing should be considered in the future to confirm the results of this study.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_19 | Pages 23 - 23
1 Dec 2014
Prins J de Beer M
Full Access

Background:

With the increase in the average age of the population, the incidence of symptomatic rotator cuff tears will also increase. Combined with more access to information via the internet etc., the patient population is more informed of the treatment modalities available and is expecting good reproducible results of their surgeries.

Study:

288 of 426 consecutive open rotator cuff repairs (2010–2012) were examined at 6 month follow up and evaluated for ranges of motion, the integrity of the deltoid and specifically the sonographic integrity of the cuff. All procedures were done in the same manner by the same surgeon (TdB). At the 6 months follow-up all had a sonar of the repaired cuff.

As a second part of the study 319 of 462 consecutive cuff repair patients were phoned and evaluated by means of the ASES score insofar satisfaction with their shoulder as well as functional outcome are concerned.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_4 | Pages 29 - 29
1 Feb 2014
van Hooff M O'Dowd J Spruit M de Kleuver M Fairbank J van Limbeek J
Full Access

Background

Combined physical and psychological (CPP) programmes are widely recommended for Chronic Low Back Pain (CLBP) patients, but not often implemented. Patients with longstanding CLBP participating in a two-week CPP programme improve in functional status and quality of life and this is maintained at two-year follow up. One-year follow-up data is available of 955 participants.

Purpose:

Evaluation of one-year follow-up outcomes of a large cohort (n=848) compared to previously published results of the first 107 patients.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_29 | Pages 30 - 30
1 Aug 2013
de Beer M
Full Access

Purpose:

The objective of this study was to determine the tensile strength of the different components of the rotator cuff tendons and their relationship to rotator cuff tears.

Method:

The tests were done on a newly designed and built test-bench that performed the tests at a consistent rupture speed. The tests were done on four fresh frozen cadaver shoulders. The capsular and tendinous layers of the rotator cuff were divided leaving them only attached on the humeral side. Separate tensile tests were done on these tendons, after they were divided into 10 mm wide strips before testing. The tendon thickness was also measured.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_29 | Pages 78 - 78
1 Aug 2013
de Beer M
Full Access

Purpose:

To determine the insertion of the different layers of the rotator cuff and apply it to rotator cuff tears. Anatomical insertion of the rotator cuff holds the key to a proper anatomical repair.

Method:

A study of the rotator cuff insertion was done in conjunction with MSc student department Anatomy. The rotator cuff consists of a capsular and tendinous layer. They have different mechanical properties. The capsular layer inserts ± 3 mm more medially on the tuberosity and the tendinous layer more laterally. It was shown that the superficial layer extends beyond the greater tuberosity and connects the supra-spinatus tendon to the sub-scapularis tendon via the bicepital groove. This connection was called the “rotator hood”. The “rotator hood” has a mechanically advantageous insertion, is a strong structure with a compressive force on the proximal humerus.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 119 - 119
1 Jan 2013
Bayliss L van Drunen G Whitwell D Giele H Gibbons M van de Sande M
Full Access

Segmental excision of long-bone sarcomas can require complex reconstruction, often resulting in the use of prosthetic replacements at a young age.

The use of vascularised free fibula grafting (VFFG) is well established as a reconstruction modality in sarcoma surgery.

Aims

To analyse the experience of two European sarcoma centres and their use of vascularised free fibula grafting as a primary and revision procedure in limb salvage for diaphyseal long-bone defects in sarcoma surgery.

Methods

A retrospective analysis was carried out of 70 consecutive patients undergoing VFFG between 1996 and 2009 under the Oxford Sarcoma Service (Nuffield Orthopaedic Centre) and the Dutch Orthopaedic Tumour Society (Leiden University Hospital). Clinical and radiological assessments were made and functional outcome scores collected.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 302 - 302
1 Sep 2012
Van Der Heijden L Van De Sande M Nieuwenhuijse M Dijkstra P
Full Access

Background

Giant cell tumours of bone (GCT) are benign bone tumours with a locally aggressive character. Local recurrence is considered the main complication of surgical treatment and is described in up to 50% of patients. Intralesional curettage with the use of adjuvants like phenol or polymethylmetacrylate (PMMA) is recommended as initial treatment, significantly decreasing the risk of recurrence. However, risk factors for local recurrence in skeletal GCT have not yet been firmly established and a golden standard for local therapy remains controversial.

Objective

The identification of risk factors predisposing for an increased risk of local recurrence. In addition, different surgical techniques are compared to identify the optimal surgical approach for the identified risk factors.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XL | Pages 143 - 143
1 Sep 2012
Korduba L Loving L Klein R De Luise M Patel A Kester M
Full Access

INTRODUCTION

Many studies have looked at the effects of titanium tibial baseplates compared to cobalt chrome baseplates on backside wear. However, the surface finish of the materials is usually different (polished/unpolished) [1,2]. Backside wear may be a function not only of tray material but also of the locking mechanism. The purpose of this study was to evaluate the wear performance of conventional polyethylene inserts when mated with titanium tibial trays or cobalt chrome tibial trays that both have non-polished topside surfaces.

MATERIALS AND METHODS

Three titanium (Ti) trays were used along with three cobalt chrome (CoCr) trays. The Ti trays underwent Type II anodization prior to testing. All trays were Triathlon® design (Stryker Orthopaedics, Mahwah, NJ). Tibial inserts were manufactured from GUR 1020 conventional polyethylene then vacuum/flush packaged and sterilized in nitrogen (30 kGy). Appropriate sized CoCr femoral components articulated against the tibial inserts (Triathlon®, Stryker Orthopaedics, Mahwah, NJ).

Surface roughness of the tibial trays was taken prior to testing using white light interferometry (Zygo Corp, Middlefield, CT). A 6-station knee simulator (MTS, Eden Prairie, MN) was used for testing. Two phases were conducted. The first phase used a normal walking profile, as dictated by ISO 14243-3 [3]. The second phase used waveforms created specifically for stair climbing kinematics. Testing was conducted at a frequency of 1 Hz for 2 million cycles for each test with a lubricant of Alpha Calf Fraction serum (Hyclone Labs, Logan, UT) diluted to 50% with a pH-balanced 20-mMole solution of deionized water and EDTA (protein level = 20 g/l) [4]. The serum solution was replaced and inserts were weighed for gravimetric wear at least every 0.5 million cycles. Standard test protocols were used for cleaning, weighing and assessing the wear loss of the tibial inserts [5]. Soak control specimens were used to correct for fluid absorption with weight loss data converted to volumetric data (by material density). Statistical analysis was performed using the Student's t-test (p<0.05).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXX | Pages 4 - 4
1 Jul 2012
van de Sande M van der Heijden L Gibbons M Dijkstra P
Full Access

Introduction

Local recurrence of Giant cell tumours of bone (GCT) is considered the main complication of surgical treatment (50%). Intra-lesional curettage with adjuvants like phenol or polymethylmethacrylate (PMMA) is recommended as initial treatment, decreasing the risk of recurrence. However, risk factors for local recurrence in skeletal GCT have not yet been firmly established and a golden standard for treatment remains controversial.

Aim of this study is identification of risk factors for recurrence in GCT, specifically after intra-lesional curettage with or without adjuvants.

Methods

In a retrospective single-institution study 191 patients treated for GCT between 1964 and 2009 were included. Mean follow-up was 111 months (range 12-415). The recurrence-free survival and hazards for different treatment strategies and various patient and tumour characteristics were determined.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXVI | Pages 79 - 79
1 Jun 2012
El-Malky M Barrett C De Matas M Pillay R
Full Access

Purpose

The treatment of C2 fractures with collar, halo or surgery can all be justified depending on the patient. In our unit, primary treatment is with a halo: in a previous study presented at BASS we found an 85% fusion rate. In a follow on study, we wished to assess the outcome in those patients who underwent surgical treatment.

Methods

The discharge logbook was examined retrospectively to identify patients who had posterior instrumentation for C2 fractures from 2008-2010 inclusive. Discharge summaries, clinic letters and radiology images/reports from PACS were analysed to obtain data regarding primary treatment, outcome, necessity for delayed treatment and radiological evidence of union.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XVIII | Pages 2 - 2
1 May 2012
de Andrés M Roach H
Full Access

BACKGROUND

Although osteoarthritis (OA) is not an inflammatory arthritis, a characteristic feature of OA is increased production of pro-inflammatory cytokines, such as interleukin 1beta (IL-1b), by articular chondrocytes. In fact, the degree of articular inflammation is often associated with disease progression; indicating that this process probably contributes to articular damage. Suppressor of cytokine signalling (SOCS) proteins are, as the name suggests, inhibitors of cytokine signalling that function via the JAK/STAT pathway (Janus kinase/signal transducers and activators of transcription). Eight SOCS proteins, SOCS1-SOCS7 and CIS-1 (cytokine-inducible SH2-domain-1 with similar structure to the other SOCS proteins) have been identified, of which, SOCS1-3 and CIS-1 are the best characterised. Reduced expression of SOCS proteins would be predicted to result in increased cytokine responsiveness and thereby could contribute to OA pathology.

OBJECTIVES

1) To compare the expression of SOCS1-3 and CIS-1 in normal and OA human articular chondrocytes and 2) to analyze the effects of IL-1b on SOCS1-3 and CIS-1 mRNA expression.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XIV | Pages 32 - 32
1 Apr 2012
van de Sande M Dijkstra PS Taminiau A
Full Access

The purpose of this study was to compare the outcome, complications and survival of the three most commonly used surgical reconstructions of the proximal humerus in adult patients after trans-articular tumour resection.

Method

Between1985 and 2005 thirty-eight consecutive proximal humeral reconstructions using either, allograft-prosthesis composite (n=10), osteoarticular allograft (n=13) or a modular tumour prosthesis (n=14), were performed in our clinic. Their mean follow-up was ten years (nine months to 25 years). Of these, twenty-seven were disease free at latest follow-up (Mean follow-up 16.8 years) and ten had died of disease (4.2 years). Complications and implant survival with revision surgery as end-point are presented for the total group of patients, functional scores for surviving patients only.

Results

The endoprosthetic group presented the smallest complication rate of 21%, compared to 40% in the allograftprosthesis- composite and 62% in the osteoarticular allograft group. Only one revision was performed in the endoprosthetic group, in a case of shoulder instability. Infection after revision (n=3), pseudoarthrosis (n=2), fracture of the allograft (n=3), and shoulder instability (n=4) were major complications of allograft use in general. Kaplan-Meier-analysis showed a significantly better implant survival for the endoprosthetic group (log-rank p=0.002). At final follow-up the MusculoSkeletal Tumour Society scores averaged at; 72% for the allograft-prosthetic-composite (n=7, mean follow-up 19 years), 76% for the osteoarticular allograft (n=3, 16 years), and 77% for the endoprosthetic reconstruction (n=10, 6 years) groups.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_X | Pages 72 - 72
1 Apr 2012
Sundaram R Shaw D De Matas M Pillay R
Full Access

To review the accuracy of our systematic process in preventing wrong level lumbar microdiscectomy.

X-ray is used to identify the correct level for the skin incision to be made, x-ray is again used if the surgeon is in doubt prior performing the flavotomy. Following a lumbar microdiscectomy a Watson Chane is inserted into the empty disc space and an intra-operative x-ray is taken to confirm the level the discectomy has occurred. Observers A and B independently reviewed intra-operative x-ray in patients undergoing lumbar microdiscectomies and correlated the accuracy of the x-ray in determining correct level surgery against the pre-operative MRI scan and the preposed level of surgery.

123 patients, 66 males and 57 females underwent 127 lumbar microdiscectomy procedures between 2007 and 2009. The levels where surgery occurred are;- L2/3 -1 patient, L3/4–8 patients, L4/5–53 patients and L5/S1-65 patients.

Kappa coefficient was used to determine inter-observer and Pearson Correlation coefficient was used to determine the X-ray and MRI relationship

Percentage of patients who required a pre-flavotomy x-ray level check are:- L2/3–100%, L3/4-63%, L4/5–45%, and L5/S1–40%. Pearson's correlation in confirming the level lumbar microdiscectomy was performed using final x-ray and the pre-operative MRI scan was 1. Kappa coefficient between observer A and B was 1.

This process of using intra-operative x-ray in determining the exact level where lumbar microdiscectomy was performed is 100% accurate. This is our standard process in preventing wrong level surgery for lumbar microdiscectomy.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_I | Pages 53 - 53
1 Jan 2012
Abdulkareem IH De Matas M
Full Access

The Royal Liverpool and Broadgreen University Hospital, Liverpool, UK

Plasmacytoma is the localised form of multiple myeloma, which can affect any part of the body including the axial skeleton (Kelly et al, 2006; Ampil et al, 1995). These myelomas/plasmacytomas arise from one malignant clone of cells, which secrete the same type of immunoglobulin. Where the clone of cells remains localised, it is known as plasmacytoma, but when there is spread of the malignancy to multiple bones and marrow, it is known as multiple myeloma (Boccadoro and Pileri, 1995).

We present a case of solitary sacral bone plasmacytoma (SBP), in a seventy year old man which presented as low back pain, following a fall. He was neurologically intact, and had no sphincteric incontinence, but MRI revealed a large expansile lesion in S1, which caused severe spinal stenosis, involving the left L5 exiting foramen, with an irregular area of low signal posteriorly. Bone scan showed increased tracer uptake in L5 and a mixed hot/photopaenic appearance in the mid-sacral region indicating tumor involvement. Myeloma screen confirmed that the serum IgA was high, with positive kappa monoclonal band, positive Bence Jones Protein (BJP), normal IgM and IgG, and normal calcium profile. CT-guided biopsy revealed sheets of mature plasma cells, consistent with the diagnosis. Fine needle aspiration biopsy of an enlarged groin lymph node revealed neoplastic infiltration, consistent with myeloma. Skeletal survey and CT chest/abdomen/pelvis (CAP) were not contributory. The patient had six courses of radiotherapy and improved remarkably, and is being considered for chemotherapy as well as follow up in the out-patients' department.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 1 | Pages 37 - 42
1 Jan 2012
Affatato S Traina F De Fine M Carmignato S Toni A

Alumina–alumina bearings are among the most resistant to wear in total hip replacement. Examination of their surfaces is one way of comparing damage caused by wear of hip joints simulated in vitro to that seen in explanted bearings. The aim of this study was to determine whether second-generation ceramic bearings exhibited a better pattern of wear than those reported in the literature for first-generation bearings. We considered both macro- and microscopic findings.

We found that long-term alumina wear in association with a loose acetabular component could be categorised into three groups. Of 20 specimens, four had ‘low wear’, eight ‘crescent wear’ and eight ‘severe wear’, which was characterised by a change in the physical shape of the bearing and a loss of volume. This suggests that the wear in alumina–alumina bearings in association with a loose acetabular component may be variable in pattern, and may explain, in part, why the wear of a ceramic head in vivo may be greater than that seen after in vitro testing.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 528 - 528
1 Nov 2011
Hourlier H Marié F Fennema P Reina N De Lestang M
Full Access

Purpose of the study: Conventional techniques for implantation of a TKA allow a neutral mechanical axis (HKA 180±3) in 70 to 86% of patients. The purpose of this work was to evaluate the contribution of intraoperative radiologic assistance for this objective.

Material and methods: We conducted a prospective randomised study in a single-operator consecutive series of cemented TKA, model TC-SB, excluding revisions and frontal deviations > 25. The series included 65 women and 39 men, mean age 73 years. All operations were performed on a radiolucent table. An extramedullary guide was used for the tibial cut and an intramedullary guide for the femoral cup. Patient randomisation was done after the cuts. According to the randomisation, the orientation of the cuts in the frontal plane was measured radiographically using a fluoroscope and an aiming plate situated on the hip, then the ankle. Secondary cuts were made if the angular deviation was greater than 1°. The position of the TKA assisted by the fluoroscope (group R+, n=52) and that of the non-assisted TKA (group R-, n=52) was assessed on the digitalised goniometry.

Results: Mean operative time was 70 minutes in group R+ and 59 minutes in group R-. In group R+, the mean mechanical alignment was 3.9 varus preoperatively and 0.13 valgus postoperatively (5 valgus to 3 varus) with 91% in the ±3 range. In group R-, the mean mechanical alignment was 6.7 varus preoperatively and 0.06 varus postoperatively (6 varus to 5 valgus) with 80% of the cases in the ±3 range. The standard deviation was 2 in group R+ and 2.7 in group R-, with no significant difference.

Discussion: The accuracy of the implantation obtained with the conventional instrumentation for the TC-SB prosthesis is among the best reported in the literature. Intraoperative radiological assistance enabled a tighter spread of the results around the mechanical alignment. The technique was simple to use and precise. The mean duration of exposure to the fluoroscope was 3 s (PDS 3 – 35 gray cm2).

Conclusion: We reserve this assistance in priority for patients with major bone deformities or medullary obstacles.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 538 - 538
1 Nov 2011
Gabrion V Gabrion A Sérot J Mertl P De Lestang M
Full Access

Purpose of the study: Dementia in the elderly subject aged over 75 years is currently an important public health problem. An important part of the activity in orthopaedic surgery involves this age group. In 2007, 16,812 elderly persons aged over 75 years were hospitalised in our University Hospital (769 in orthopaedic surgery): 1380 patients were considered demented (40 in orthopaedic surgery). The purpose of this work was to evaluate the cognitive function of this population in a teaching hospital unit of orthopaedic and traumatology surgery where the prevalence of dementia appears to be underestimated.

Material and methods: Data were collected over a period of four years. This study concerned 113 patient, including 83 women, mean age 81.8 years (range 75–92). The reason for hospitalisation was predominantly fracture of the proximal femur (73%); thirty patients had hip, knee or shoulder arthroplasty and 24 other situations. The Mini Mental State Examination (MMSE) was performed.

Results: The MMSE could be interpreted for 100 patients: < 24 for 33, 24 to 26 for 29 and > 27 for 38. Among the 24 patients with no cognitive disorder known before hospitalization (nine patients known to be demented were removed from the analysis) and for whom the MMSE was completed entirely, the most frequent alterations were noted for attention, calculation, and recall-memory items.

Discussion: Finally, one-third of the subjects aged over 75 years and hospitalized in our unit presented signs of altered cognitive function according to the MMSE(< 24). This score is one of the criteria for frailness of the elderly subject. This population has an unstable precarious medicosocial status with defective adaptation to stress and change in environment. These persons are exposed to a high risk of morbidity, mortality, dependence, longer hospital stay and institutionalization. The purpose of this screening is to improve management for these patients by proposing more specifically adapted care.

Conclusion: It is thus indispensable to screen for cognitive disorders systematically in patients aged over 75 years hospitalized in a surgery unit. The MMSE score can be used for this purpose. This work is in favour of a physician or better a geriatrician within the unit who could be financed directly by his-her own sector of activity.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 508 - 508
1 Nov 2011
Manopoulos P Havet É Mertl P Parizon P Lardanchet J De Lestang M
Full Access

Purpose of the study: Restrained implants with intrinsic stability guaranteed by a large central stem have been developed for revision knee arthroplasty, irrespective of the underlying cause. Successful restraint implies excellent fixation of the prosthetic implants which can be obtained using press-fit centromedullary stems. The purpose of this work was to assess the long-term results of this mode of fixation in this indication and to search for clinical correlations with potential radiological images around the stems.

Material and methods: We report 46 cases of Sigma®PFC TC3 revision total knee prostheses reviewed retrospectively at two years with a mean follow-up of eight years. Mean age at surgery was 68 years. Revision was indicated for aseptic loosening (n=24) and septic loosening (n=22). The knee society criteria were used for the clinical evaluation. Radiographic measurements were made semiautomatically with the Imagika® software.

Results: The mean clinical score improved from 42 points preoperatively to 84.7 at two years and 83.7 at last follow-up. Outcome was excellent (n=30), good (n=7), fair (n=1) and poor (n=1). The mean function score improved from 34.3 preoperatively to 69.1 at two years and 64.2 at last follow-up. Radiographic alignment was correct in all cases. The press-fit effect was observed for 63% of the femoral implants and 76% for the tibial implants. Around the stems, 57% of the implants exhibited condensation lines and 23% lucent lines measuring less than 2 mm. There was no relation between radiological findings and the clinical or functional scores. There were two failures, one for frontal instability at six years and the other for aseptic loosening at eight years. Excepting these two cases, there was one case of femoral implant migration with no clinical expression. For all other patients, the radiographic image remained unchanged between the two year check-up and the final follow-up.

Discussion: Thee presence of lucent lines or condensation lines is well known for this type of implant with long centromedullary stems. Nevertheless, this is the first clinical series evaluating the clinical impact of these radiographic images. In our opinion, these images are related to the relative mobility of these implants which should be checked regularly, although no long-term clinical expression occurs. For us, this type of implant enables good function and long-term stability.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 571 - 571
1 Nov 2011
Rouleau DM Kidder J de Villanueva JP Dynamidis S De Franco M Walch G
Full Access

Purpose: Recognition of the glenoid version is important for evaluation of different pathologies. There is no consensus on method to use to evaluate version. The purpose of this study was to compare different measurement strategies in one hundred-sixteen (116) patients with shoulder CT-scans.

Method: Scapula CT-scan axial images were revised and the cut below the base of the coracoid was selected. The glenoid version was measured according to the Friedman method (FM) and the “scapula body” methods (BM). In case of B2 glenoid three different reference lines have been measure: the neo-glenoid NG (posterior erosion surface), paleo-glenoid PG (original glenoid surface) and the intermediate-glenoid IG (line from anterior and posterior edge). Three orthopaedic surgeons independently examined the images two times and intra/inter-observer reliability was calculated using Intra-Class Correlation (ICC). The objective of this paper is to define which method shows best reliability.

Results: Group 1 (B2 excluded n=53): The average glenoid version was significantly different between two measurement techniques for all three observers, with an average of – 7.29° for BM technique and – 10.43° for FM. Intra-observer reliability was excellent for both methods (ICC: 0.958–0.979 for FM; 0.940–0.970 for BM). Inter-observer reliability was excellent for both methods (FM: ICC= 0.977; BM: ICC= 0.962). The light superiority of the first method was not significant. For group 2 – B2 glenoid (n=63): six different measures of version were taken resulting by two scapula reference line (FM and BM) and three glenoid reference line (PG, IG, NG). The average glenoid versions were significantly different (p0.82). The inter-observer reliability were also very-good or excellent for all methods (ICC > 0.79). The most reliable method for measurement of B2 glenoid version was the association of the Friedman line for the scapula axis and the intermediate glenoid line with excellent intra observer reliability (ICC > 0.957) and inter-observer reliability (ICC=0.954).

Conclusion: Measurement of glenoid version on axial cut of a Ct-scan is highly reliable. Significant differences exist between measures depending which method is used, underlying the importance of a consensus for research and clinical purpose. Despite very good performance of all methods, authors recommend the use of the Friedman method for the scapula axis reference and an intermediate glenoid line in case of B2 glenoid.