header advert
Results 21 - 40 of 77
Results per page:
Bone & Joint Research
Vol. 11, Issue 3 | Pages 180 - 188
1 Mar 2022
Rajpura A Asle SG Ait Si Selmi T Board T

Aims

Hip arthroplasty aims to accurately recreate joint biomechanics. Considerable attention has been paid to vertical and horizontal offset, but femoral head centre in the anteroposterior (AP) plane has received little attention. This study investigates the accuracy of restoration of joint centre of rotation in the AP plane.

Methods

Postoperative CT scans of 40 patients who underwent unilateral uncemented total hip arthroplasty were analyzed. Anteroposterior offset (APO) and femoral anteversion were measured on both the operated and non-operated sides. Sagittal tilt of the femoral stem was also measured. APO measured on axial slices was defined as the perpendicular distance between a line drawn from the anterior most point of the proximal femur (anterior reference line) to the centre of the femoral head. The anterior reference line was made parallel to the posterior condylar axis of the knee to correct for rotation.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_16 | Pages 21 - 21
1 Dec 2021
Langley B Page R Whelton C Chalmers O Morrison S Cramp M Dey P Board T
Full Access

Abstract

Objectives

The objective of this proof of concept study was to explore whether some total hip arthroplasty (THA) patients with well-functioning implants achieve normal sagittal plane hip kinematics during walking gait.

Methods

Sagittal plane hip kinematics were recorded in eleven people with well-functioning THA (71 ± 8 years, Oxford Hip Score = 46 ± 3) and ten healthy controls (61 ± 5 years) using a three-dimensional motion capture system as they walked over-ground at a self-selected velocity. THA patients were classified as high- or low-functioning (HF and LF, respectively) depending on whether the mean absolute difference between their sagittal plane hip kinematics was within one standard deviation of the control group (5.4°) or not. Hedge's g effect size was used to compare the magnitude of the difference from the control group for the HF and LF THA groups.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_16 | Pages 18 - 18
1 Dec 2021
Brown M Wilcox R Isaac G Anderson J Board T Williams S
Full Access

Abstract

OBJECTIVES

Dual mobility (DM) total hip replacements (THRs) were introduced to reduce the risk of hip dislocation in at-risk patients. DM THRs have shown good overall survivorship and low rates of dislocation, however, the mechanisms which describe how these bearings function in-vivo are not fully understood. This is partly due to a lack of suitable characterisation methodologies which are appropriate for the novel geometry and function of DM polyethylene liners, whereby both surfaces are subject to articulation. This study aimed to develop a novel semi-quantitative geometric characterisation methodology to assess the wear/deformation of DM liners.

METHODS

Three-dimensional coordinate data of the internal and external surfaces of 14 in-vitro tested DM liners was collected using a Legex 322 coordinate measuring machine. Data was input into a custom Matlab script, whereby the unworn reference geometry was determined using a sphere fitting algorithm. The analysis method determined the geometric variance of each point from the reference surface and produced surface deviation heatmaps to visualise areas of wear/deformation. Repeatability of the method was also assessed.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_14 | Pages 26 - 26
1 Nov 2021
Board T Galvain T Kakade O Mantel J
Full Access

To estimate the clinical and economic burden of primary total hip arthroplasty (THA) dislocation in England.

Retrospective propensity score-matched evaluation of patients with and without dislocation following primary THA using the UK Clinical Practice Research Datalink linked and Hospital Episode Statistics datasets with a 2-year follow-up.

13,044 patients with total hip replacements met the inclusion criteria (mean age 69.2, 60.9% female) of which 154 (1.18%) suffered at least one postoperative hip dislocation. The mean number of dislocations per patient was 1.44 with a maximum of 4. Approximately one-third of the patients with dislocation (32.5%) had more than one dislocation. Among patients with a hip dislocation 148 patients (96.7%) had at least one closed reduction and 20 patients (13.1%) had revision surgery. Two-year median direct medical costs were £14,748 (95% confidence interval [CI] £12,028 to £20,638) higher with vs. without dislocation (+227%). On average, patients with a dislocation had significantly greater healthcare resource utilization and significantly less improvement in EuroQol-5D (EQ-5D) index (0.24 vs. 0.45; p<0.001) and Visual Analogue Scale (VAS) (1.58 vs. 11.23; p=0.010) scores and Oxford Hip Scores (13.02 vs. 21.98; p<0.001).

This is the first study to estimate the economic burden of dislocation in the UK throughout the entire patient pathway. Dislocation following total hip replacement is a costly complication, both in terms of economic costs and to the functional quality of life of the patient. Efforts to reduce the risks of dislocation should remain at the forefront of hip research.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_14 | Pages 7 - 7
1 Nov 2021
Morlock M Bätz J Beverland D Board T Lampe F Konow T
Full Access

The influence of the surgical process on implant loosening and periprosthetic fractures (PPF) as major complications in uncemented total hip arthroplasty (THA) have rarely been studied due to the difficult quantification. Meanwhile registry analyses have clearly shown a decrease in complications with increasing experience. The goal of this study was to determine the extent of variability in THA stem implantation between highly experienced surgeons with respect to implant-size, -position, press-fit, contact area, primary stability and the effect of using a powered impaction tool.

Primary hip stems were implanted in 16 cadaveric femur pairs by three experienced surgeons using manual and powered impaction. Quantitative CTs were taken before and after each process step and stem tilt, canal-fill-ratio, pressfit and contact area between bone and implant determined. 11 femur pairs were additionally tested for primary stability under cyclic loading conditions.

Higher variations in press-fit and contact area between the surgeons for manual impactions compared to powered were observed. Stem tilt and implant sizing varied between surgeons but not between impaction methods. Larger stems exhibited less micromotion compared to smaller stems.

Larger implants may increase PPF risk, while smaller implants reduce primary stability. The reduced variation for powered impactions indicates that appropriate measures may promote a more standardized process. The observed variations between the experienced surgeons may represent the acceptable range for this specific stem design. Variability in the implantation process warrants further investigations since certain deviations e.g. a stem tilt towards varus, might increase bone stresses and PPF risk.


The protective effect of lipped polyethylene uncemented acetabular liners against revision THA for instability has been reported. However, the effect of lip size has not been explored, nor has the effect on revision THA for loosening. We aimed to determine if uncemented acetabular liner geometry, and lip size, influences the risk of revision THA for instability or loosening.

202511 primary THAs with uncemented polyethylene acetabular components were identified from the NJR dataset (2003 – 2017). The effect of acetabular liner geometry and lip size on the risk of revision THA for instability or loosening was investigated using binomial regression and competing risks survival analyses (competing risks were revision for other causes or death) adjusting for age, gender, ASA grade, diagnosis, side, institution type, surgeon grade, surgical approach, head size and polyethylene crosslinking.

The distribution of acetabular liners was: neutral – 39.4%, offset neutral – 0.9%, 10-degree – 34.5%, 15-degree – 21.6%, 20-degree – 0.8%, offset reorientating – 2.82%. There were 690 (0.34%) revision THAs for instability and 604 (0.3%) for loosening. Significant subhazard risk ratios were found in revision THA for instability with 10-degree (0.63), 15-degree (0.48) and offset reorientating (1.6) liners, compared to neutral liners. There was no association found between liner geometry and risk of revision THA for loosening.

This Registry based study confirms a significantly lower risk of revision THA for instability when a lipped liner is used, compared to neutral liners, and a higher risk with the use of offset reorientating liners. Furthermore, 15degree liners seem to have a lower risk than 10degree liners. We did not find an association between acetabular liner geometry and revision THA for loosening.

10- and 15-degree lipped polyethylene liners seem to offer a lower revision risk over neutral liners, at least at medium term followup. Further studies are required to confirm if this benefit continues into the long-term.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_10 | Pages 10 - 10
1 Aug 2021
Jain S Lamb J Townsend O Scott C Kendrick B Middleton R Jones S Board T West R Pandit H
Full Access

Cemented total hip replacement (THR) provides excellent outcomes and is cost-effective. Polished taper-slip (PTS) stems demonstrate successful results and have overtaken traditional composite-beam (CB) stems. Recent reports indicate they are associated with a higher risk of postoperative periprosthetic femoral fracture (PFF) compared to CB stems. This study evaluates risk factors influencing fracture characteristics around PTS and CB cemented stems.

Data were collected for 584 PFF patients admitted to eight UK centres from 25/05/2006-01/03/2020. Radiographs were assessed for Unified Classification System (UCS) grade and Arbeitsgemeinschaft für Osteosynthesefragen/Orthopaedic Trauma Association (AO/OTA) type. Statistical comparisons investigated relationships by age, gender, and stem fixation philosophy (PTS versus CB). The effect of multiple variables was estimated using multinomial logistic regression to estimate odds ratios (OR) with 95% confidence intervals (CI).

Median (IQR) age was 79.1 (72.0–86.0) years, 312 (53.6%) patients were female, and 495 (85.1%) stems were PTS. The commonest UCS grade was type B1 (278, 47.6%). The commonest AO/OTA type was spiral (352, 60.3%). Metaphyseal-split fractures occurred only with PTS stems with an incidence of 10.1%. Male gender was associated with a five-fold reduction in odds of a type C fracture (OR 0.22, 95% CI 0.12 to 0.41, p<0.001) compared to a type B fracture. CB stems were associated with significantly increased odds of transverse fracture (OR 9.51, 95% CI 3.72 to 24.34, p <0.001) and wedge fracture (OR 3.72, 95% CI 1.16 to 11.95, p <0.05) compared to PTS stems.

This is the largest study investigating PFF characteristics around cemented stems. The commonest fracture types are B1 and spiral fractures. PTS stems are exclusively associated with metaphyseal-split fractures, but their incidence is low. Males have lower odds of UCS grade C fractures compared to females. CB stems had higher odds of bending type fractures (transverse and wedge) compared to PTS stems. Biomechanical testing is needed for validation and investigation of modifiable factors which may reduce the risk of unstable fracture patterns requiring complex revision surgery over internal fixation.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_10 | Pages 28 - 28
1 Aug 2021
Whelton C Barrow J Singhal R Board T
Full Access

Orthopaedic surgical hoods rely on an intrinsic fan to force clean external air over the wearer and allow potentially contaminated and expired air to flow down and away from the surgical field. Carbon dioxide (CO2) is produced through aerobic metabolism and can potentially accumulate inside the hood. Levels above 2500ppm have been shown to affect cognitive and practical function in flight simulator studies. Maximum Health and Safety Executive (HSE) 8-hour exposure limit is 5000ppm There is a paucity of data on real-world CO2 levels experienced during arthroplasty surgery whilst wearing a hood.

CO2 levels were continuously recorded during 31 elective arthroplasties, both primary and revision. Data was collected for surgeon and assistant. Data was recorded at 0.5Hz throughout the procedure utilising a Bluetooth CO2 detector, worn inside a Stryker Flyte surgical helmet worn with a toga gown. Four surgeons contributed real time data to the study. This data was augmented with experimental data, investigating varying fan speeds and activity levels.

Median operative duration was 82 minutes (range 36–207).

The average CO2 level across all procedures was 2952ppm, with 22 of the cases having a mean above 2500ppm, but none having a mean above 5000ppm.

For each procedure, the time spent above 2500 and 5000 ppm was calculated, with the average being 68.4 % and 5.6% respectively.

The experimental data demonstrated higher CO2 levels with lower fan speed, and at higher activity levels, and levels exceeding 15000 ppm during gentle exercise. During operative cases, low fan speed cases did have a marginally higher mean CO2 value than high fan speed (3033.02 and 2903.56 respectively) but the small numbers of cases (n=10) where this data was captured limit the relevance of this difference.

The use of surgical helmets for elective orthopaedic surgery, can results in CO2 levels regularly rising to a point which may affect cognitive function. This study recommends the use of a higher fan speed where possible to minimise the risk of such CO2 levels, and recommends further research in this area.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_10 | Pages 34 - 34
1 Aug 2021
Ramavath A Leong J Siney P Kay P Divecha H Board T
Full Access

Principles of bone preservation and restoration of biomechanical alignment should be followed during revision total hip arthroplasty (THA). Where possible, conservative femoral revision techniques and even reconstructive de-escalation involving using primary stems should be considered. This study aims to investigate the outcome of patients who have undergone conservative femoral revision THA in our Institution.

We retrospectively identified patients from our Institution's revision arthroplasty database who had cemented, or un-cemented primary stems implanted during revision THA of a previous stemmed femoral implant. Our primary outcome measure was all-cause re-revision THA with a secondary outcome measure of improvement in Oxford hip score (OHS). Radiographic evidence of stem loosening and post-op complications were recorded.

Between 02/12/2014 to 12/12/2019, there were 226 patients identified with a mean follow up of 2 years (1–5 years). The majority of cases were represented by Paprosky type 1 (63%) and type 2 (25%) femoral defects. There were 45 patients (20%) who underwent impaction bone grafting (IBG) and 43 patients (19%) who had a cement in cement (CinC) femoral revision and cemented primary stem in 137 (60%), 1 uncemented stem with no IBG or CinC revision. Kaplan Meier survival for all-cause re-revision THA was 93.7% (95% CI: 88.3 – 100) at 3 years. The reasons for re-revision included 4 periprosthetic fractures, 4 dislocations, 1 deep infection, 1 loosening of femoral component and 1 loosening of acetabular component. Pre- and post-operative OHS scores were available in 137 hips (60%) with a mean improvement of 13. Radiographic review revealed 7% of cases with evidence of loosening in 1 or more Gruen zones.

Our early results support the use of conservative femoral revision THA techniques where appropriate, with low complication and re-revision rates. Revisions using primary femoral components, where appropriate, should be considered in surgical planning to avoid unnecessary reconstructive escalation.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_10 | Pages 40 - 40
1 Aug 2021
Holleyman R Stamp G Board T Bankes M Khanduja V Malviya A
Full Access

Chondral hip injuries are common secondary to femoroacetabular impingement (FAI). Treatment with arthroscopic procedures including chondroplasty and microfracture is becoming increasingly common but literature is limited to case series at specialist centres. The aim of this study is to compare outcomes of arthroscopic acetabular chondral procedures using the NAHR dataset (UK) which represents the largest series to date.

All adult Arthroscopies recorded in the NAHR from Jan 2012 were available for inclusion. Exclusions included significant arthritis and femoral, complex or revision chondral procedures. Patients completed iHOT-12 & EQ-5D Index pre-operatively, 6 and 12 months. Data was analysed using T-test/ANOVA for between group/within group for continuous variables, chi square test for categorical variables and linear regression model for multivariable analysis.

5,752 patients, 60% female. 27% Chondroplasty, 5% Microfracture, 68% no Chondral Procedure. Maximum acetabular Outerbridge classification 14% Grade 1, 15% Grade 2, 17% Grade 3, 8% Grade 4, 9% no damage, not recorded in 37%. Higher proportion of Cam impingement in association with chondral treatments and a larger proportion of patients with no impingement recorded in group with no chondral procedures. There was a significant improvement versus baseline for all groups in iHOT-12 and EQ-5D Index (p<0.0001) including Grade four Outerbridge. There was significantly greater improvement in pre-operative scores in the chondroplasty group compared to the microfracture group at 6 and 12 months (p<0.05).

Following hip arthroscopy, patients with chondral procedures experienced improved outcome scores despite Outerbridge 4 chondral damage. Presence of cam lesions are more commonly associated with chondral treatments. Good outcomes were maintained up to 12 months for chondral procedures, regardless of age or impingement pathology however pincers improved less and patients over 40 years took longer to see improvement.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_10 | Pages 1 - 1
1 Aug 2021
Barrow J Foster A Kenawey M Board T
Full Access

The decision to undertake THA in a child is complex and surgery challenging. Pre-operatively patients' typically have significant pain and mobility restriction. Little is published on the functional gains after THA in this group.

The aim of this study was therefore to measure the impact THA had on the PROMS in our young patients undergoing THA, to determine QoL improvement.

This was a prospective, consecutive cohort study of patients under the age of 17 years undergoing THA by a single surgeon in a tertiary referral centre. Patient electronic notes, radiographs, and PROMS (EQ5D-Y, Oxford Hip Score (OHS) and modified Harris Hip Score (mHHS)) were reviewed.

12 children (8 females and 4 males) underwent THA before their 17th birthday, with 5 undergoing bilateral operations (17 THA total). The mean age was 14.6 years (10.75–16.9) and mean follow-up 1.5 years. Nine of the THA were undertaken for congenital syndromes, 4 for AVN, 2 for Perthe's disease and 1 for dysplasia and idiopathic chondrolysis. The mean pre-operative OHS was 15 (1–33) improving to 31 (19–39) at 6-weeks, 44 (42–46) at a year and 48 (47–48) at 3 years. mHHS improved from a pre-operative mean of 25 (0–56) to 60 (37–92) at 6-weeks, 65 (38–84) at a year and 91 (91) at 3 years. The EQ-VAS mean score pre-operatively was 35 (8–100) improving at 6-weeks to 73 (55–96), 84 (76–96) at a year and 92 (76–100) at 3 years. All patients achieved MCID or higher for OHS. 6 patients were wheelchair users preop. All patients were independent walkers at follow-up. There were no complications.

THA in children is safe and leads to a significant positive impact on QoL as measured with validated PROMS scores. Wheelchair users can reliably gain independent walking. Further follow-up is required understand the long-term outcomes.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_10 | Pages 23 - 23
1 Aug 2021
Holleyman R Sohatee M Bankes M Andrade T McBryde C Board T Conroy J Wilson M Malviya A Khanduja V
Full Access

FAI may cause pain or functional impairment for an individual, as well as potentially resulting in arthritis and degeneration of the hip joint. Results from recent randomised control trials demonstrate the superiority of surgery over physiotherapy in patients with FAI. However, there is paucity of evidence regarding which factors influence outcomes for FAI surgery, most notably on patient reported outcomes measures (PROMs).

Our study looks to explore factors influencing the outcomes for patients undergoing surgery for FAI utilising data from the Non-Arthroplasty Hip Registry.

This study is a retrospective analysis of data collected prospectively via the NAHR database. Patients meeting the inclusion criteria, who underwent surgery between January 2011 and September 2019 were identified and included in the study. Follow-up data was captured in September 2020 to allow a minimum of 12 months follow-up.

Patients consenting to data collection received questionnaires to determine EQ-5D Index and iHOT-12 scores preoperatively and at 6 months, 1, 2- and 5-year follow-up.

Changes in outcome scores were analysed for all patients and sub-analysis was performed looking at the influence of; FAI morphological subtype, age, and sex, on outcome scores.

Our cohort included 4,963 patients who underwent arthroscopic treatment for FAI. There was significant improvement from pre-operative PROMs when compared with those at 6 and 12 months.

Pre-operatively, and at 12-month follow-up, iHOT-12 scores were significantly better for the cam / mixed groups compared to the pincer group (p<0.01).

In multivariable regression analysis, pincer pathology and a high-grade chondral lesion were associated significantly poorer iHOT-12 improvement at 6 and 12 months (p<0.05)

Age (<40 vs >40) demonstrated no statistical significance when considering 12 months outcome scores.

This study demonstrates that hip arthroscopy is an effective treatment for patients with symptomatic FAI and shows statistically significant improvements at 12 months.

The findings of this study are relevant to orthopaedic surgeons who manage young adults with hip pathology. This will help them to; predict which patients may benefit from operative intervention, and better inform patients, when undertaking shared decision making.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_10 | Pages 14 - 14
1 Aug 2021
Matharu G Blom A Board T Whitehouse M
Full Access

Considerable debate exists regarding which agent(s) should be preferred for venous thromboembolism (VTE) chemical prophylaxis following joint replacement. We assessed the practice of surgeons regarding VTE chemical prophylaxis for primary THR and TKR, pre and post issuing of updated NICE guidance in 2018.

A survey, circulated through the British Hip Society and regional trainee networks/collaboratives, was completed by 306 UK surgeons at 187 units. VTE chemical prophylaxis prescribing patterns for surgeons carrying out primary THR (n=258) and TKR (n=253) in low-risk patients were assessed post publication of 2018 NICE recommendations. Prescribing patterns before and after the NICE publication were subsequently explored. Questions were also asked about surgeon equipoise for participation in future RCTs.

Following the new guidance, 34% (n=87) used low-molecular weight heparin (LMWH) alone, 33% (n=85) aspirin (commonly preceded by LMWH), and 31% (n=81) direct oral anticoagulants (DOACs: with/without preceding LMWH) for THR. For TKR, 42% (n=105) used aspirin (usually monotherapy), 31% (n=78) LMWH alone, and 27% (n=68) DOAC (with/without preceding LMWH). NICE guidance changed the practice of 34% of hip and 41% of knee surgeons, with significantly increased use of aspirin preceded by LMWH for THR (before=25% vs. after=73%;p<0.001), and aspirin for TKR (before=18% vs. after=84%;p<0.001). Significantly more regimens were NICE guidance compliant after the 2018 update for THR (before=85.7% vs. after=92.6%;p=0.011) and TKR (before=87.0% vs. after=98.8%;p<0.001). Support from surgeons for future RCTs was dependent on the clinical question, ranging from 48% participation in trials (effectiveness of aspirin vs. a DOAC) to 79% (effectiveness of 14 days LMWH vs. 28 days LMWH).

Over one-third of surveyed surgeons changed their VTE chemical prophylaxis in response to 2018 NICE recommendations, with more THR and TKR surgeons now compliant with latest NICE guidance. The major change in practice was an increased use of aspirin for VTE chemical prophylaxis. Furthermore, there is an appetite amongst UK surgeons for participating in future RCTs, with a trial comparing standard versus extended duration LMWH likely feasible in current practice.


Cemented acetabular components commonly have a long posterior wall (LPW). Alternative components have a hooded or offset reorientating geometry, theoretically to reduce the risk of THR instability. We aimed to determine if cemented acetabular component geometry influences the risk of revision surgery for instability or loosening.

The National Joint Registry for England, Wales and Northern Ireland (NJR) dataset was analysed for primary THAs performed between 2003 – 2017. A cohort of 224,874 cemented acetabular components were identified. The effect of acetabular component geometry on the risk of revision for instability or for loosening was investigated using binomial regression adjusting for age, gender, ASA grade, diagnosis, side, institution type, operating surgeon grade, surgical approach, polyethylene crosslinking and head size. A competing risk survival analysis was performed with the competing risks being revision for other indications or death.

Among the cohort of subjects included, the distribution of acetabular component geometries was: LPW – 81.2%, hooded – 18.7% and offset reorientating – 0.1%. There were 3,313 (1.47%) revision THAs performed, of which 815 (0.36%) were for instability and 838 (0.37%) were for loosening. Compared to the LPW group, the adjusted subhazard ratio of revision for instability in the hooded group was 2.29 (p<0.001) and 4.12 (p=0.047) in the offset reorientating group. Likewise, the subhazard ratio of revision for loosening was 2.43 (p<0.001) in the hooded group and 11.47 (p<0.001) in the offset reorientating group. A time-varying subhazard ratio of revision for instability (hooded vs LPW) was found, being greatest within the first 6 months.

This Registry based study confirms a significantly higher risk of revision THA for instability and for loosening when a cemented hooded or offset reorientating acetabular component is used, compared to an LPW component. Further research is required to clarify if certain patients benefit from the use of hooded or offset reorientating components, but we recommend caution when using such components in routine clinical practice.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_10 | Pages 33 - 33
1 Aug 2021
Holleyman R Sohatee M Bankes M Witt J Andrade T Board T McBryde C Conroy J Wilson M Khanduja V Malviya A
Full Access

Pelvic re-orientation osteotomy is a well-recognised treatment of young adults with developmental dysplasia of the hip (DDH).

The most commonly used technique is the periacetabular osteotomy (PAO), however, some surgeons favour a triple osteotomy. These techniques can also be utilised for acetabular retroversion leading to FAI.

Despite the published literature on these techniques, the authors note a scarcity of evidence looking at patient reported outcome measures (PROMs) for these procedures.

This was a retrospective analysis of prospectively collected data utilising the UK NAHR. All patients who underwent pelvic osteotomy from January 2012 to November 2019 were identified from the NAHR database. Patients who consented to data collection received EQ-5D index and iHOT-12 questionnaires, with scores being collected pre-operatively and at 6, 12 and 24 months post-operatively.

Nine hundred and eleven (911) patients were identified with twenty-seven (27) undergoing a triple osteotomy, the remaining patients underwent PAO. Mean age was 30.6 (15–56) years and 90% of patients were female. Seventy-nine (79) (8.7%) of patients had the procedure for acetabular retroversion leading to FAI

Statistical analysis, of all patients, showed significant improvement (p<0.001) for; iHOT-12 scores (+28 at 6-months, +33.8 at 12-months and +29.9 at 24-months)

Similarly there was significant improvement (p<0.001) in EQ-5D index (+0.172 at 6-months, +0.187 at 12-months and +0.166 at 24-months)

Pre-operatively, and at each follow-up time-period, raw scores were significantly better in the DDH group compared to the FAI group (p<0.05); however, the improvement in scores was similar for both groups.

For both scoring measures, univariable and multivariable linear regression showed poorer pre-operative scores to be strongly significant predictors of greater post-operative improvement at 6 and 12 months (p<0.0001).

Conclusions/Discussion

This study shows that pelvic osteotomy is a successful treatment for DDH and FAI, with the majority of patients achieving significant improvement in outcome scores which are maintained up to 24 months post-operatively. The patients with FAI have significantly reduced raw scores preoperatively and, perhaps, are functionally more limited.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_10 | Pages 39 - 39
1 Aug 2021
Rajan A Leong J Singhal R Siney P Shah N Board T
Full Access

Trabecular metal (TM) augments are designed to support an uncemented socket in revision surgery when adequate rim fit is not possible. We have used TM augments in an alternative arrangement, to contain segmental defects to facilitate impaction bone grafting (IBG) and cementation of a cemented socket. However, there is a paucity of literature supporting the use of this technique. We present one of the largest studies to date, reporting early outcomes of patients from a tertiary centre.

A single-centre retrospective analytical study of prospectively collected data was performed on patients who had undergone complex acetabular reconstruction using TM augments, IBG and a cemented cup. All patients operated between 2015 and 2019 were included. We identified 105 patients with a mean age of 74yrs. The mean follow-up was 2.3 years(1–5.5yrs). Our primary outcome measure was all-cause revision of the construct. The secondary outcome measures were, Oxford hip score (OHS), radiographic evidence of cup migration/loosening and post-op complications.

Eighty-four out of 105 patients belonged to Paprosky grade IIb, IIc or IIIa. Kaplan-Meier survivorship for all-cause revision was 96.36% (CI, 90.58–100.00) at 2 years with 3 failures. Two were due to early infection which required two-stage re-revision. The third was due to post-operative acetabular fracture which was then re-revised with TM augment, bone graft and large uncemented cup. Pre-op and post-op matched OHS scores were available for 60 hips(57%) with a mean improvement of 13 points. Radiographic analysis showed graft incorporation in all cases with no evidence of cup loosening. The mean vertical cup migration was 0.5mm (Range −5 to 7mm). No other complications were recorded.

This study shows that reconstruction of large acetabular defects during revision THA using a combination of TM augments to contain the acetabulum along with IBG to preserve the bone stock and a cemented socket is a reliable and safe technique with low revision rates and satisfactory clinical and radiographic results. Long term studies are needed to assess the possibility of preservation and regeneration of bone stock.


Bone & Joint Open
Vol. 2, Issue 7 | Pages 466 - 475
8 Jul 2021
Jain S Lamb J Townsend O Scott CEH Kendrick B Middleton R Jones SA Board T West R Pandit H

Aims

This study evaluates risk factors influencing fracture characteristics for postoperative periprosthetic femoral fractures (PFFs) around cemented stems in total hip arthroplasty.

Methods

Data were collected for PFF patients admitted to eight UK centres between 25 May 2006 and 1 March 2020. Radiographs were assessed for Unified Classification System (UCS) grade and AO/OTA type. Statistical comparisons investigated relationships by age, gender, and stem fixation philosophy (polished taper-slip (PTS) vs composite beam (CB)). The effect of multiple variables was estimated using multinomial logistic regression to estimate odds ratios (ORs) with 95% confidence intervals (CIs). Surgical treatment (revision vs fixation) was compared by UCS grade and AO/OTA type.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_2 | Pages 36 - 36
1 Mar 2021
Langley B Whelton C Page R Chalmers O Cramp M Morrison S Dey P Board T
Full Access

Abstract

Objectives

The objective of this study was to determine the kinematic factor(s) underlying the reduction in walking velocity displayed by total hip arthroplasty (THA) patients in comparison to healthy controls during walking gait.

Methods

Eleven patients with well-functioning THA (71 ± 8 years, Oxford Hip Score = 46 ± 3) and ten healthy controls (61 ± 5 years) participated within this study. Sagittal plane lower limb kinematics were captured using a 10 camera Qualisys motion capture system, sampling at 200Hz, as participants walked overground at a self-selected pace. Bivariate linear regression was used to explore the relationship between walking velocity and a number of kinematic variables in a deterministic manner. Kinematic variables significantly associated with walking velocity were compared between THA and healthy groups utilising independent samples t-tests.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_2 | Pages 42 - 42
1 Mar 2021
Williams S Jones A Wilcox R Isaac G Traynor A Board T Williams S
Full Access

Abstract

Objectives

Impingement in total hip replacements (THRs), including bone-on-bone impingement, can lead to complications such as dislocation and loosening. The aim of this study was to investigate how the location of the anterior inferior iliac spine (AIIS) affected the range of motion before impingement.

Methods

A cohort of 25 CT scans (50 hips) were assessed and nine hips were selected with a range of AIIS locations relative to the hip joint centre. The selected CT Scans were converted to solid models (ScanIP) and THR components (DePuy Synthes) were virtually implanted (Solidworks). Flexion angles of 100⁰, 110⁰, and 120⁰ were applied to the femur, each followed by internal rotation to the point of impingement. The lateral, superior and anterior extent of the AIIS from the Centre of Rotation (CoR) of the hip was measured and its effect on the range of motion was recorded.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_2 | Pages 39 - 39
1 Mar 2021
Jimenez-Cruz D Masterson A Dubey M Board T Williams S
Full Access

Abstract

OBJECTIVES

Abnormal joint mechanics have been proposed as adversely affecting natural hip joint tribology, whereby increased stress on the articular cartilage from abnormal loading leads to joint degeneration. The aim of this project was to assess the damage caused by different loading conditions on the articular surfaces of the porcine hip joint in an experimental simulator.

METHODS

Porcine hip joints were dissected and mounted in a single station hip simulator (SimSol, UK) and tested under loading scenarios (that corresponded to equivalent of different body mass index's’ (BMI) in humans), as follows:“Normal” (n=4), the loading cycle consisted of a simplified gait cycle based on a scaled version of a simplified twin-peak human gait cycle, the peak load was 900N (representative of a healthy BMI). Representative of an “Overweight” BMI (n=3), as the normal cycle with a peak load of 1,130N Representative of an “Obese” BMI (n=1), as the normal cycle with a peak load of 1,340N Tests were conducted at 1Hz for 14,400 cycles in Ringers solution; photogrammetry was used to characterise the appearance of the cartilage and labrum pre, during and post simulation. the appearance and location of damage was recorded.