header advert
Results 1 - 20 of 405
Results per page:
The Bone & Joint Journal
Vol. 99-B, Issue 3 | Pages 303 - 309
1 Mar 2017
Beaulé PE Bleeker H Singh A Dobransky J

Aims. Joint-preserving surgery of the hip (JPSH) has evolved considerably and now includes a number of procedures, including arthroscopy, surgical dislocation, and redirectional osteotomies of the femur and acetabulum. There are a number of different factors which lead to failure of JPSH. Consequently, it is of interest to assess the various modes of failure in order to continue to identify best practice and the indications for these procedures. . Patients and Methods. Using a retrospective observational study design, we reviewed 1013 patients who had undergone JPSH by a single surgeon between 2005 and 2015. There were 509 men and 504 women with a mean age of 39 years (16 to 78). Of the 1013 operations, 783 were arthroscopies, 122 surgical dislocations, and 108 peri-acetabular osteotomies (PAO). We analysed the overall failure rates and modes of failure. Re-operations were categorised into four groups: Mode 1 was arthritis progression or organ failure leading to total hip arthroplasty (THA); Mode 2 was an Incorrect diagnosis/procedure; Mode 3 resulted from malcorrection of femur (type A), acetabulum (type B), or labrum (type C) and Mode 4 resulted from an unintended consequence of the initial surgical intervention. Results. At a mean follow-up of 2.5 years, there had been 104 re-operations (10.2%) with a mean patient age of 35.5 years (17 to 64). There were 64 Mode 1 failures (6.3%) at a mean of 3.2 years following JPSH with a mean patient age of 46.8 years (18 to 64). There were 17 Mode 2 failures (1.7%) at a mean of 2.2 years post-JPSH with a mean patient age of 28.9 years (17 to 42) (2% scopes; 1% surgical dislocations). There were 19 Mode 3 failures (1.9%) at a mean of 2.0 years post-JPSH, with a mean patient age of 29.9 years (18 to 51) (2% scopes; 2% surgical dislocations; 5% PAO). There were 4 Mode 4 failures (0.4%) at a mean of 1.8 years post-JPSH with a mean patient age of 31.5 years (15 to 43). Using the modified Dindo-Clavien classification system, the overall complication rate among JPSHs was 4.2%. Conclusion. While defining the overall re-operation and complication rates, it is important to define the safety and effectiveness of JPSH. Standardisation of the modes of failure may help identify the best practice. Application of these modes to large clinical series, such as registries, will assist in further establishing how to improve the efficacy of JPSH. Cite this article: Bone Joint J 2017;99-B:303–9


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_5 | Pages 99 - 99
1 Apr 2018
Song S Park C Liang H Bae D
Full Access

Background. The knowledge about the common mode of failure and each period in primary and revision TKAs offers useful information to prevent those kinds of failure in each surgery. However, there has been limited report that simultaneously compared the mode of failure between primary and revision TKAs using single prosthesis. We compared the survival rate, mode of failure, and periods of each mode of failure between primary and revision TKAs. Methods. A consecutive cohort of 1606 knees (1174 patients) of primary TKA and 258 knees (224 patients) of revision TKA using P.F.C® prosthesis was retrospectively reviewed. The mean follow-up periods of primary and revision TKAs were 10.2 and 10.8 years, respectively. We compared the above variables between primary and revision TKAs. Results. The average 5-, 10-, 15-year survivor rate of primary TKA were 99.1% (CI 95%, ±0.3%), 96.7% (CI 95%, ±0.7%), and 85.4% (CI 95%, ±2.0%). They were 97.8% (CI 95%, ±1.0%), 91.4% (CI 95%, ±2.5%), and 80.5% (CI 95%, ±4.5%) in revision TKA. The common mode of failure included polyethylene wear, loosening, and infection in both primary and revision TKAs. The most common mode of failure was polyethylene wear in primary TKAs and infection in revision TKAs. The mean periods of polyethylene wear and loosening were not significantly different between primary and revision TKAs, but the mean period of infection was significantly long in revision TKA (4.8 years vs. 1.2 years, p=0.003). Conclusions. The survival rate decreased with time, especially after 10 years in both primary and revision TKAs. The continuous efforts are required to prevent and detect various modes of failure during the long-term follow-up after primary and revision TKAs. More careful attention is necessary to detect the late infection as a mode of failure after revision TKA. Level of Evidence. Level III, Therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 2 | Pages 178 - 183
1 Feb 2011
Streit MR Merle C Clarius M Aldinger PR

Peri-prosthetic femoral fracture after total hip replacement (THR) is associated with a poor outcome and high mortality. However, little is known about its long-term incidence after uncemented THR. We retrospectively reviewed a consecutive series of 326 patients (354 hips) who had received a CLS Spotorno replacement with an uncemented, straight, collarless tapered titanium stem between January 1985 and December 1989. The mean follow-up was 17 years (15 to 20). The occurrence of peri-prosthetic femoral fracture during follow-up was noted. Kaplan-Meier survival analysis was used to estimate the cumulative incidence of fracture. At the last follow-up, 86 patients (89 hips) had died and eight patients (eight hips) had been lost to follow-up. A total of 14 fractures in 14 patients had occurred. In ten hips, the femoral component had to be revised and in four the fracture was treated by open reduction and internal fixation. The cumulative incidence of peri-prosthetic femoral fracture was 1.6% (95% confidence interval 0.7 to 3.8) at ten years and 4.5% (95% confidence interval 2.6 to 8.0) at 17 years after the primary THR. There was no association between the occurrence of fracture and gender or age at the time of the primary replacement. Our findings indicate that peri-prosthetic femoral fracture is a significant mode of failure in the long term after the insertion of an uncemented CLS Spotorno stem. Revision rates for this fracture rise in the second decade. Further research is required to investigate the risk factors involved in the occurrence of late peri-prosthetic femoral fracture after the implantation of any uncemented stem, and to assess possible methods of prevention


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 170 - 170
1 Sep 2012
Scott C Bhattacharya R Macdonald D Wade F Nutton R
Full Access

Unicompartmental knee replacements (UKRs) have inconsistent and variable survivorships reported in the literature. It has been suggested that many are revised for ongoing pain with no other mode of failure identified. Using a medial UKR with an all-polyethylene non-congruent tibial component from 2004–7, we noted a revision rate of 9/98 cases (9.2%) at a mean of 39 months. Subchondral sclerosis was noted under the tibial component in 3/9 revisions with well fixed implants, and the aim of this study was to investigate this as a mode of failure. 89 UKRs in 77 patients were investigated radiographically (at mean 50 months) and with SF-12 and Oxford Knee scores at mean follow up 55 months. Subjectively 23/89 cases (25%) had sclerosis under the tibial component. We describe a method of quantifying this sclerosis as a greyscale ratio (GSR), which was significantly correlated with presence/absence of sclerosis (p<0.001). Significant predictors of elevated GSR (increasing sclerosis) were female sex (p<0.001) and elevated BMI (P=0.010) on both univariate and multivariate analysis. In turn, elevated GSR was significantly associated with poorer improvement in OKS (p<0.05) at the time of final follow up. We hypothesise that this sclerosis results from repetitive microfracture and adaptive remodelling in the proximal tibia due to increased strain. Finite element analysis is required to investigate this further, but we suggest caution should be employed when considering all polyethylene UKR implants in older women and in those with BMI >35


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_11 | Pages 23 - 23
1 Jun 2016
Singh S
Full Access

Introduction. In the early 2000s hip resurfacing became an established bone conserving hip arthroplasty option particularly for the fit and active patient cohort. The performance of second-generation metal-on-metal bearings had led to the reintroduction of hip resurfacing. The Birmingham Hip resurfacing (BHR) was introduced in 1997. This was followed by a number of different designs of the hip resurfacing. The Durom hip resurfacing was introduced in 2001. These two designs had different metallurgical properties, design parameters particularly clearance and different implantation techniques. Data from joint registries show that both prosthesis perform well. Objectives. Our objective was to perform a retrospective survival analysis comparing the Birmingham to the Durom hip resurfacing and analyse the mode of failures of the cases revised. Methods. Data was collected prospectively but analysed retrospectively. The two cohorts comprised patients treated by two senior surgeons at different units. The follow up range was 1 to 14 years with a mean of 10 years. The end-point was revision for any cause. However this was further substratified. Results. The outcome of all patients was known. The two cohorts exhibited no significant difference in demographics. No failures in either cohort were attributed to adverse reaction to metal debris. Revision for any cause was analysed by plotting Kaplan-Meier Survival curves. The Durom cohort (n=273) had 5 deaths and 9 revisions. The Birmingham cohort (n=567) had 5 deaths and 22 revisions. The Kaplan-Meier survival curves for the two resurfacing designs were different. The Durom cohort demonstrated a concave curve with more early failures. This was contrary to the BHR's convex curve with higher incidence of late failures. We analysed the data by substratifying into failure of femoral or acetabular component and neck fractures. Conclusions. The Kaplan-Meier survival analysis demonstrates that the Durom hip resurfacings had a higher rate of early failure. However extrapolation of the curves suggests that the Durom may have a superior long term survival compared to the BHR. We postulate that this may be due to the femoral implantation technique with less late failures in Duroms and an apparent acceleration of failures in BHR cohort around the ten year stage. Joint registry data also reflect this pattern


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 143 - 143
1 Mar 2013
Chen D Bertollo N Stanford R Harper W Walsh W
Full Access

Aim. Cementless prosthesis is one of the major bone-implant interface fixation methods in total joint replacement. Grit blasted surface, hydroxyapatite coated surface and plasma sprayed metallic porous coating have been popularly used. The latter has demonstrated higher bone implant mechanical stability in previous laboratory study in early and middle stages. However, question remains what the mechanism is to make it performing better and how to improve them further. This study is designed to examine the mode of failure in bone-implant interface in a sheep model. Method. Plasma sprayed porous coated (TiPL); hydroxyapatite (HA) coated and and grit blasted (TiGB) titanium implants were examined in the study. Each type has 36 specimens. Implants were inserted into cortical bones in a press-fit fashion in a total of 22 sheep bilateral hind limbs. Specimens were retrieved at 4 weeks and 12 weeks. Push- out testing was performed to just reach ultimate failure. Failed bone-implant interface were investigated by histology and BSEM. The percentage of failure at bone-coating interface, bone itself fracture, coating itself failure, and coating-substrate dissociation were measured by BSEM. Results. In TiPL group, failure occurred mainly at new bone itself on ingrowing new bone and adjacent bone, with 74% at 4 weeks, and 82% at 12 weeks. The percentages were significantly higher than that of the failure at bone-porous coating dissociation. Furthermore, the percentage of failure occurred at bone was also higher in TiPS group than in the other groups at both time points. In HA group, the main proportion of failure, 69%, occurred at bone-HA dissociation at 4 weeks, higher than the 25% at bone itself fracture. 57% of failure occurred at HA-substrate dissociation at 12 weeks, which was followed by HA coating itself breakage (Figure 1). Bone itself fracture has the lowest proportion of only 4% breakage at 12 weeks. HA coating revealed micro cracks at some area although not all of them were failed. In TiGB group, failure mainly occurred at bone-implant surface dissociation at both time points. Conclusion. The failure mode at the HA and TiGB groups demonstrate that new bone was less likely to break, or stronger, than bone-implant surface interface at early stage, and new bone at middle stage was stronger than the other interfaces. The bone ingrowth to metallic porous coating results in that major proportion failure has to occur at bone anchorage, either at the entry level or at adjacent bone. The anchorage is the reason why TiPS has higher mechanical shear strength in previous study. Improving bone itself remodelling or maturing process may increase the porous coated implant in vivo mechanical strength; improving HA quality and HA-substrate adhesion may enhance HA coated implant performance; and improving bone implant surface bonding may strengthen grit blasted implant mechanical stability


The Bone & Joint Journal
Vol. 102-B, Issue 8 | Pages 1048 - 1055
1 Aug 2020
Cox I Al Mouazzen L Bleibleh S Moldovan R Bintcliffe F Bache CE Thomas S

Aims

The Fassier Duval (FD) rod is a third-generation telescopic implant for children with osteogenesis imperfecta (OI). Threaded fixation enables proximal insertion without opening the knee or ankle joint. We have reviewed our combined two-centre experience with this implant.

Methods

In total, 34 children with a mean age of five years (1 to 14) with severe OI have undergone rodding of 72 lower limb long bones (27 tibial, 45 femoral) for recurrent fractures with progressive deformity despite optimized bone health and bisphosphonate therapy. Data were collected prospectively, with 1.5 to 11 years follow-up.


The Bone & Joint Journal
Vol. 96-B, Issue 11_Supple_A | Pages 105 - 111
1 Nov 2014
Vince KG

There are many reasons why a total knee replacement (TKR) may fail and qualify for revision. Successful revision surgery depends as much on accurate assessment of the problem TKR as it does on revision implant design and surgical technique. Specific modes of failure require specific surgical solutions. Causes of failure are often presented as a list or catalogue, without a system or process for making a decision. In addition, strict definitions and consensus on modes of failure are lacking in published series and registry data. How we approach the problem TKR is an essential but neglected aspect of understanding knee replacement surgery. It must be carried out systematically, comprehensively and efficiently. Eight modes of failure are described: 1) sepsis; 2) extensor discontinuity; 3) stiffness; 4) tibial- femoral instability; 5) patellar tracking; 6) aseptic loosening and osteolysis; 7) periprosthetic fracture and 8) component breakage. A ninth ‘category’, unexplained pain is an indication for further investigation but not surgery. Cite this article: Bone Joint J 2014;96-B(11 Suppl A):105–11


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIII | Pages 17 - 17
1 Jul 2012
Murray O Lee S Mckenna R Kelly M Roberts J
Full Access

Early failure of metal-on-metal (MoM) total hip replacements (THR) is now well established. We review 93 consecutive patients with CPT¯ stems MoM THR. Our series demonstrates a new mechanism of failure, which may be implant combination specific.

Between January 2005 and June 2009, 93 consecutive MoM total hip replacements were preformed using CPT stems by 3 surgeons at our unit. 73 CPT¯ stems, Metasul¯ Large Diameter Heads (LDH) with Durom¯ acetabulae and 20 CPT¯ stems, Metasul¯ 28mm diameter heads in Allofit¯ shells (zimmer). Clinical outcomes were collected prospectively before surgery, at 3 months, 1 year, 2 years, 3 years, and at 5 years post surgery. Revision for any cause was taken as the primary endpoint and the roentgenograms and explanted prostheses were analyzed for failure patterns.

In the LDH/Durom¯ group a total of 13 (18%) patients required revision (figs. 1) at a median of 35 months (range 6-44). 6 (8%) for periprosthetic fracture. All 6 periprostethic fractures were associated with minimal or no trauma and all had ALVAL identified histologically.

To date there have been no failures in the CPT¯/28mm head Allofit¯ group. Several failures demonstrated bone loss in Gruen zones 8 ± 9 ± 10 (fig. 2).

We demonstrate an unacceptably high rate of failure in CPT¯ MoM LDH hip replacements, with a high failure secondary to periprosthetic fracture and postulate a mechanism associated with local toxicity to metal ions. We strongly advise against this combination of prosthesis.


The Bone & Joint Journal
Vol. 98-B, Issue 1_Supple_A | Pages 84 - 88
1 Jan 2016
Vince K

The term mid-flexion instability has entered the orthopaedic literature as a concept, but has not been confirmed as a distinct clinical entity. The term is used freely, sometimes as a synonym for flexion instability. However, the terms need to be clearly separated. A cadaver study published in 1990 associated joint line elevation with decreased stability at many angles of flexion, but that model was not typical of clinical scenarios. The literature is considered and it is proposed that the more common entity of an uncorrected flexion contracture after a measured resection arthroplasty technique is more likely to produce clinical findings that suggest instability mid-flexion.

It is proposed that the clinical scenario encountered is generalised instability, with the appearance of stability in full extension from tight posterior structures.

This paper seeks to clarify whether mid-flexion instability exists as an entity distinct from other commonly recognised forms of instability.

Cite this article: Bone Joint J 2016;98-B(1 Suppl A):84–8.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_13 | Pages 20 - 20
17 Jun 2024
Jagani N Harrison W Davenport J Karski M Ring J Smith R Clough T
Full Access

Aims. Retrospective review of a consecutive series of 1,168 total ankle replacements (TAR) performed at Wrightington, to analyse modes of failure and clinical outcomes following TAR failure. Methods. All patients undergoing TAR between November 1993 – June 2019 were collated (4–25 year follow-up; mean 13.7 years). 6 implants were used (300 STAR, 100 Buechal Pappas, 509 Mobility, 118 Zenith, 41 Salto and 100 Infinity). 5 surgeons, all trained in TAR, performed the surgery. Modes of failure were collated and clinical and radiological outcomes recorded for the revisional surgery following failure of the TAR. Results. 156 (13.4%) TARs failed (47STAR 15.6%, 16BP 16%, 77Mobility 15.1%, 6Salto 14.6%, 10Zenith 8.5% and 0Infinity 0%). Mean time to failure 5.8 years (0.1- 21.4 years). The 4 most common modes of failure were 44.9% aseptic loosening, 11.5% gutter pain, 10.9% infection and 10.3% recurrent edge loading. 50 underwent conversion to tibiotalocalcaneal (TTC) fusion with nail with 9 (18%) failing to fuse. 31 underwent revision TAR with 2 (6.5%) subsequently failed. 22 underwent ankle fusion with 10 (45%) failing to fuse. 21 underwent polyethylene exchange of which 8 (38%) had further poly failure. 20 (12.8%) were managed conservatively, 2 (1.3%) required below knee amputation and 6 were listed but lost to follow-up. 81 of the 1168 (7%) consecutive cohort were lost to follow-up. Conclusions. 13.4% of the TAR cohort have failed at average follow-up 13.7 years. There was no difference in failure modes across the implant designs. Whilst the fixed bearing has the shortest follow-up, it may be performing better as there have been no failures so far. Prior to October 2016, most revisions were to fusion (TTC 18% failure rate, ankle 45% failure rate), whereas post 2016, 57% patients elected for revision TAR (6.5% failure)


The Bone & Joint Journal
Vol. 102-B, Issue 8 | Pages 967 - 980
1 Aug 2020
Chou TA Ma H Wang J Tsai S Chen C Wu P Chen W

Aims. The aims of this study were to validate the outcome of total elbow arthroplasty (TEA) in patients with rheumatoid arthritis (RA), and to identify factors that affect the outcome. Methods. We searched PubMed, MEDLINE, Cochrane Reviews, and Embase from between January 2003 and March 2019. The primary aim was to determine the implant failure rate, the mode of failure, and risk factors predisposing to failure. A secondary aim was to identify the overall complication rate, associated risk factors, and clinical performance. A meta-regression analysis was completed to identify the association between each parameter with the outcome. Results. A total of 38 studies including 2,118 TEAs were included in the study. The mean follow-up was 80.9 months (8.2 to 156). The implant failure and complication rates were 16.1% (95% confidence interval (CI) 0.128 to 0.200) and 24.5% (95% CI 0.203 to 0.293), respectively. Aseptic loosening was the most common mode of failure (9.5%; 95% CI 0.071 to 0.124). The mean postoperative ranges of motion (ROMs) were: flexion 131.5° (124.2° to 138.8°), extension 29.3° (26.8° to 31.9°), pronation 74.0° (67.8° to 80.2°), and supination 72.5° (69.5° to 75.5°), and the mean postoperative Mayo Elbow Performance Score (MEPS) was 89.3 (95% CI 86.9 to 91.6). The meta-regression analysis identified that younger patients and implants with an unlinked design correlated with higher failure rates. Younger patients were associated with increased complications, while female patients and an unlinked prosthesis were associated with aseptic loosening. Conclusion. TEA continues to provide satisfactory results for patients with RA. However, it is associated with a substantially higher implant failure and complication rates compared with hip and knee arthroplasties. The patient’s age, sex, and whether cemented fixation and unlinked prosthesis were used can influence the outcome. Level of Evidence: Therapeutic Level IV. Cite this article: Bone Joint J 2020;102-B(8):967–980


Bone & Joint Open
Vol. 3, Issue 10 | Pages 804 - 814
13 Oct 2022
Grammatopoulos G Laboudie P Fischman D Ojaghi R Finless A Beaulé PE

Aims. The primary aim of this study was to determine the ten-year outcome following surgical treatment for femoroacetabular impingement (FAI). We assessed whether the evolution of practice from open to arthroscopic techniques influenced outcomes and tested whether any patient, radiological, or surgical factors were associated with outcome. Methods. Prospectively collected data of a consecutive single-surgeon cohort, operated for FAI between January 2005 and January 2015, were retrospectively studied. The cohort comprised 393 hips (365 patients; 71% male (n = 278)), with a mean age of 34.5 years (SD 10.0). Over the study period, techniques evolved from open surgical dislocation (n = 94) to a combined arthroscopy-Hueter technique (HA + Hueter; n = 61) to a pure arthroscopic technique (HA; n = 238). Outcome measures of interest included modes of failures, complications, reoperation, and patient-reported outcome measures (PROMs). Demographic, radiological, and surgical factors were tested for possible association with outcome. Results. At a mean follow-up of 7.5 years (SD 2.5), there were 43 failures in 38 hips (9.7%), with 35 hips (8.9%) having one failure mode, one hip (0.25%) having two failure modes, and two hips (0.5%) having three failure modes. The five- and ten-year hip joint preservation rates were 94.1% (SD 1.2%; 95% confidence interval (CI) 91.8 to 96.4) and 90.4% (SD 1.7%; 95% CI 87.1 to 93.7), respectively. Inferior survivorship was detected in the surgical dislocation group. Age at surgery, Tönnis grade, cartilage damage, and absence of rim-trimming were associated with improved preservation rates. Only Tönnis grade was an independent predictor of hip preservation. All PROMs improved postoperatively. Factors associated with improvement in PROMs included higher lateral centre-edge and α angles, and lower retroversion index and BMI. Conclusion. FAI surgery provides lasting improvement in function and a joint preservation rate of 90.4% at ten years. The evolution of practice was not associated with inferior outcome. Since degree of arthritis is the primary predictor of outcome, improved awareness and screening may lead to prompt intervention and better outcomes. Cite this article: Bone Jt Open 2022;3(10):804–814


The Bone & Joint Journal
Vol. 105-B, Issue 6 | Pages 635 - 640
1 Jun 2023
Karczewski D Siljander MP Larson DR Taunton MJ Lewallen DG Abdel MP

Aims. Knowledge on total knee arthroplasties (TKAs) in patients with a history of poliomyelitis is limited. This study compared implant survivorship and clinical outcomes among affected and unaffected limbs in patients with sequelae of poliomyelitis undergoing TKAs. Methods. A retrospective review of our total joint registry identified 94 patients with post-polio syndrome undergoing 116 primary TKAs between January 2000 and December 2019. The mean age was 70 years (33 to 86) with 56% males (n = 65) and a mean BMI of 31 kg/m. 2. (18 to 49). Rotating hinge TKAs were used in 14 of 63 affected limbs (22%), but not in any of the 53 unaffected limbs. Kaplan-Meier survivorship analyses were completed. The mean follow-up was eight years (2 to 19). Results. The ten-year survivorship free from revision was 91% (95% confidence interval (CI) 81 to 100) in affected and 84% (95% CI 68 to 100) in unaffected limbs. There were six revisions in affected limbs: three for periprosthetic femoral fractures and one each for periprosthetic joint infection (PJI), patellar clunk syndrome, and instability. Unaffected limbs were revised in four cases: two for instability and one each for PJI and tibial component loosening. The ten-year survivorship free from any reoperation was 86% (95% CI 75 to 97) and 80% (95% CI 64 to 99) in affected and unaffected limbs, respectively. There were three additional reoperations among affected and two in unaffected limbs. There were 12 nonoperative complications, including four periprosthetic fractures. Arthrofibrosis occurred in five affected (8%) and two unaffected limbs (4%). Postoperative range of motion decreased with 31% achieving less than 90° knee flexion by five years. Conclusion. TKAs in post-polio patients are complex cases associated with instability, and one in four require constraint on the affected side. Periprosthetic fracture was the main mode of failure. Arthrofibrosis rates were high and twice as frequent in affected limbs. Cite this article: Bone Joint J 2023;105-B(6):635–640


The Bone & Joint Journal
Vol. 105-B, Issue 3 | Pages 269 - 276
1 Mar 2023
Tay ML Monk AP Frampton CM Hooper GJ Young SW

Aims. Unicompartmental knee arthroplasty (UKA) has higher revision rates than total knee arthroplasty (TKA). As revision of UKA may be less technically demanding than revision TKA, UKA patients with poor functional outcomes may be more likely to be offered revision than TKA patients with similar outcomes. The aim of this study was to compare clinical thresholds for revisions between TKA and UKA using revision incidence and patient-reported outcomes, in a large, matched cohort at early, mid-, and late-term follow-up. Methods. Analyses were performed on propensity score-matched patient cohorts of TKAs and UKAs (2:1) registered in the New Zealand Joint Registry between 1 January 1999 and 31 December 2019 with an Oxford Knee Score (OKS) response at six months (n, TKA: 16,774; UKA: 8,387), five years (TKA: 6,718; UKA: 3,359), or ten years (TKA: 3,486; UKA: 1,743). Associations between OKS and revision within two years following the score were examined. Thresholds were compared using receiver operating characteristic analysis. Reasons for aseptic revision were compared using cumulative incidence with competing risk. Results. Fewer TKA patients with ‘poor’ outcomes (≤ 25) subsequently underwent revision compared with UKA at six months (5.1% vs 19.6%; p < 0.001), five years (4.3% vs 12.5%; p < 0.001), and ten years (6.4% vs 15.0%; p = 0.024). Compared with TKA, the relative risk for UKA was 2.5-times higher for ‘unknown’ reasons, bearing dislocations, and disease progression. Conclusion. Compared with TKA, more UKA patients with poor outcomes underwent revision from early to long-term follow-up, and were more likely to undergo revision for ‘unknown’ reasons, which suggest a lower clinical threshold for UKA. For UKA, revision risk was higher for bearing dislocations and disease progression. There is supporting evidence that the higher revision UKA rates are associated with lower clinical thresholds for revision and additional modes of failure. Cite this article: Bone Joint J 2023;105-B(3):269–276


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_4 | Pages 10 - 10
8 Feb 2024
Powell-Bowns MFR Martin D Bowley A Moran M Clement ND Scott CEH
Full Access

Aim of this study was to identify reoperation rates in patients with short oblique and transverse fractures around a well fixed cemented polished taper slip stem and to determine any associations with treatment failure. Retrospective cohort study of 31 patients with AO transverse or short oblique Vancouver B1 PFFs around THA (total hip arthroplasty) cemented taper slip stems: 12 male (39%); mean age 74±11.9 (range 44–91); mean BMI 28.5±1.4 (range 16–48); and median ASA 3. Patient journeys were assessed, re-interventions reviewed. The primary outcome measure was reoperation. Time from primary THA to fracture was 11.3±7.8yrs (0.5–26yrs). Primary surgical management was fixation in 27/31 and rTHA (revision total hip arthroplasty) in 4/31. 10 of 31 (32%) patients required reoperation, 9 within 2 years of fracture: 1 following rTHA and 8 following ORIF. The commonest mode of failure was non-union (n=6). No significant associations with reoperation requirement were identified. Kaplan-Meier free from reoperation was 67.4% (49.8–85.0 95% CI) at 2 years and this was unaffected by initial management with ORIF or rTHA (Log rank 0.898). Of those reoperated, 6/10 required multiple reoperations to obtain either bony union or a stable revision construct and 13% ultimately required proximal femoral endoprostheses. The relative risk of 1 year mortality was 1.6 (0.25 to 10.1 95%CI) among patients who required reoperation compared to those who did not. These are difficult fractures to manage, should not be underestimated and patients should be counselled that there is a 30% risk of reoperation and 20% of requiring multiple reoperations


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_4 | Pages 13 - 13
3 Mar 2023
Rohra S Sinha A Kemp M Rethnam U
Full Access

Background. Dynamic Hip Screw (DHS) is the most frequently used implant in management of intertrochanteric femoral fractures. There is a known statistical relationship between a tip-apex distance (TAD) >25mm and higher rate of implant failure. Our aim was to analyse all DHS procedures performed in our trust from seventeen months and compare their TAD values to the acceptable standard of ≤25mm. Methods. All patients undergoing DHS between April 2020-August 2021 were identified from our theatre system. Additionally, those presenting to hospital with implant failures were included. Patient demographics, date of surgery, fracture classification (AO) and date/mode of failure were recorded. Intraoperative fluoroscopy images were reviewed to calculate TAD, screw location and neck shaft angles by two independent observers. Results. 215 patients were identified, five of which were excluded due to inadequate fluoroscopy. Failure was seen in 3.3% of the cohort (n=7), of which 71.4% had an unacceptable TAD. In total, 21 patients (10%) had TAD >25mm, of whom 12 had superiorly and 15 had posteriorly placed screws. There were no failures in patients with a TAD of <20mm whereas a TAD >30mm had 50% failure rate. Conclusion. This audit reinforces the importance of aiming for a low TAD (preferably <20mm) intraoperatively. It is also desirable to avoid superiorly and significantly posteriorly placed screws. Implications. Complex hip revision surgery in the elderly bears substantial financial implications to the NHS and, more importantly, causes prolonged morbidity to the patient. Adhering to established standards will ensure reduced implant failure and best patient care


The Bone & Joint Journal
Vol. 100-B, Issue 8 | Pages 1043 - 1053
1 Aug 2018
Scott CEH Turnbull GS Powell-Bowns MFR MacDonald DJ Breusch SJ

Aims. The aim of this study was to identify predictors of return to work (RTW) after revision lower limb arthroplasty in patients of working age in the United Kingdom. Patients and Methods. We assessed 55 patients aged ≤ 65 years after revision total hip arthroplasty (THA). There were 43 women and 12 men with a mean age of 54 years (23 to 65). We also reviewed 30 patients after revision total knee arthroplasty (TKA). There were 14 women and 16 men with a mean age of 58 years (48 to 64). Preoperatively, age, gender, body mass index, social deprivation, mode of failure, length of primary implant survival, work status and nature, activity level (University of California, Los Angeles (UCLA) score), and Oxford Hip and Knee Scores were recorded. Postoperatively, RTW status, Oxford Hip and Knee Scores, EuroQol-5D (EQ-5D), UCLA score, and Work, Osteoarthritis and Joint-Replacement Questionnaire (WORQ) scores were obtained. Univariate and multivariate analysis was performed. Results. Overall, 95% (52/55) of patients were working before their revision THA. Afterwards, 33% (17/52) RTW by one year, 48% (25/52) had retired, and 19% (10/52) were receiving welfare benefit. RTW was associated with age, postoperative Oxford Hip Score, early THA failure (less than two years), mode of failure dislocation, and contralateral revision (p < 0.05). No patient returned to work after revision for dislocation. Only age remained a significant factor on multivariate analysis (p = 0.003), with 79% (11/14) of those less than 50 years of age returning to work, compared with 16% (6/38) of those aged fifty years or over. Before revision TKA, 93% (28/30) of patients were working. Postoperatively only 7% (2/28) returned to work by one year, 71% (20/28) had retired, and 21% (6/28) were receiving welfare benefits. UCLA scores improved after 43% of revision THAs and 44% of revision TKAs. Conclusion. After revision THA, age is the most significant predictor of RTW: only 16% of those over 50 years old return to work. Fewer patients return to work after early revision THA and none after revision for dislocation. After revision TKA, patients rarely return to work: none return to heavy or moderate manual work. Cite this article: Bone Joint J 2018;100-B:1043–53


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 4 - 4
10 Feb 2023
Sundaram A Hockley E Hardy T Carey Smith R
Full Access

Rates of prosthetic joint infection in megaprostheses are high. The application of silver ion coating to implants serves as a deterrent to infection and biofilm formation. A retrospective review was performed of all silver-coated MUTARS endoprosthetic reconstructions (SC-EPR) by a single Orthopaedic Oncology Surgeon. We examined the rate of component revision due to infection and the rate of infection successfully treated with antibiotic therapy. We reviewed overall revision rates, sub-categorised into the Henderson groupings for endoprosthesis modes of failure (Type 1 soft tissue failure, Type 2 aseptic loosening, Type 3 Structural failure, Type 4 Infection, Type 5 tumour progression). 283 silver-coated MUTARS endoprosthetic reconstructions were performed for 229 patients from October 2012 to July 2022. The average age at time of surgery was 58.9 years and 53% of our cohort were males. 154 (71.3%) patients underwent SC-EPR for oncological reconstruction and 32 (14.8%) for reconstruction for bone loss following prosthetic joint infection(s). Proximal femur SC-EPR (82) and distal femur (90) were the most common procedures. This cohort had an overall revision rate of 21.2% (60/283 cases). Component revisions were most commonly due to Type 4 infection (19 cases), Type 2 aseptic loosening/culture negative disease (15 cases), and Type 1 dislocation/soft tissue (12 cases). Component revision rate for infection was 6.7% (19 cases). 15 underwent exchange of implants and 4 underwent transfemoral amputation due to recalcitrant infection and failure of soft tissue coverage. This equates to a limb salvage rate of 98.3%. The most common causative organisms remain staphylococcus species (47%) and polymicrobial infections (40%). We expand on the existing literature advocating for the use of silver-coated endoprosthetic reconstructions. We provide insights from the vast experience of a single surgeon when addressing patients with oncological and bone loss-related complex reconstruction problems


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 39 - 39
23 Feb 2023
Jo O Almond M Rupasinghe H Jo O Ackland D Ernstbrunner L Ek E
Full Access

Neer Type-IIB lateral clavicle fractures are inherently unstable fractures with associated disruption of the coracoclavicular (CC) ligaments. A novel plating technique using a superior lateral locking plate with antero-posterior (AP) locking screws, resulting in orthogonal fixation in the lateral fragment has been designed to enhance stability. The purpose of this study was to biomechanically compare three different clavicle plating constructs. 24 fresh-frozen cadaveric shoulders were randomised into three groups (n=8 specimens). Group 1: lateral locking plate only (Medartis Aptus Superior Lateral Plate); Group 2: lateral locking plate with CC stabilisation (Nr. 2 FiberWire); and Group 3: lateral locking plate with two AP locking screws stabilising the lateral fragment. Data was analysed for gap formation after cyclic loading, construct stiffness and ultimate load to failure, defined by a marked decrease in the load displacement curve. After 500 cycles, there was no statistically significant difference between the three groups in gap-formation (p = 0.179). Ultimate load to failure was significantly higher in Group 3 compared to Group 1 (286N vs. 167N; p = 0.022), but not to Group 2 (286N vs. 246N; p = 0.604). There were no statistically significant differences in stiffness (Group 1: 504N/mm; Group 2: 564N/mm; Group 3: 512N/mm; p = 0.712). Peri-implant fracture was the primary mode of failure for all three groups, with Group 3 demonstrating the lowest rate of peri-implant fractures (Group 1: 6/8; Group 2: 7/8, Group 3: 4/8; p = 0.243). The lateral locking plate with orthogonal AP locking screw fixation in the lateral fragment demonstrated the greatest ultimate failure load, followed by the lateral locking plate with CC stabilization. The use of orthogonal screw fixation in the distal fragment may negate against the need for CC stabilization in these types of fractures, thus minimizing surgical dissection around the coracoid and potential complications