Advertisement for orthosearch.org.uk
Results 1 - 20 of 87
Results per page:
Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 214 - 214
1 Jul 2014
McIff T Colbert K Boyer A Goodyear A Mar D
Full Access

Summary Statement. A porcine model using Yucatan minipigs was found to be very promising for the investigation of healing around transcutaneous osseointegrated implants. Pigs demonstrated surprising agility and adaptability including the ability to ambulate on three legs during the immediate postoperative period. Introduction. Previous non weight-bearing and weight-bearing caprine, canine and ovine models have evaluated design, material, and biological coating variations in an attempt to improve the wound healing and skin-implant seal around transcutaneous osseointegrated implants. Although these models have primarily been used as a window into the application of transcutaneous osseointegrated implants in humans, some important model characteristics affecting wound healing and infection have been missing including: 1) replication of the physiological tissue response, and 2) availability of a transcutaneous site with sufficient soft tissue coverage. Pig skin, like human, is relatively hairless, tightly attached to the subcutaneous tissue, vascularised by a cutaneous blood supply, and healed by means of epithelialization. Swine have been extensively utilised for superficial and deep wound healing studies and can offer ample soft tissue coverage following a lower limb amputation. Development of a porcine model is important for continued understanding and improvement of weight-bearing transcutaneous osseointegration. Methods. Two male Yucatan mini-pigs (9 months, 36kg) were fit with transcutaneous osseointegrated prostheses using a single-stage transtibial amputation and prosthesis implantation procedure. The endo-prosthesis consisted of a cylindrical intraosseous threaded section and a smooth transcutaneous section. The transcutaneous sections were smooth to promote epithelialization and deter direct skin-implant adhesion. The implants were custom manufactured from medical grade Ti-6Al-4V alloy. The exo-prosthesis, consisting of an adjustable length leg and foot, was attached by clamp to the supercutaneous portion of the implant following either one or two days of sling constraint to limit initial weight-bearing. Various exo-prosthesis designs and configurations were trialed. The animals’ behavior and gait were closely observed. Weight-bearing was monitored using a force plate. At 5 and 8 weeks, clinical, microbiological, and histological data were examined to assess wound healing and infection at the skin-bone-implant interface. Results. The pigs demonstrated surprising agility and adaptability. They were able to successfully ambulate on three legs during the post-op period before weight-bearing was permitted. They adapted quickly to changes in exo-prosthesis design, position, and length. Although bacterial colonization was verified, neither of the animals exhibited clinical signs of infection over the respective eight and five week studies. Histological results indicated that there was no skin to implant adhesion but that epithelial growth was progressing towards the implant in one animal. Healing of the transcutaneous wound site showed substantial progress but a definitive skin seal was non-existent at the eight week time point. Discussion/Conclusion. This is likely the first animal model developed, having soft tissue characteristics similar to those found in humans, in which an axially-loaded, weight-bearing implant was successfully used. Results indicated that this porcine model offers many advantages over previous models for the development, evaluation, and comparison of the various techniques being advocated to achieve successful transcutaneous osseointegration in humans. The Yucatan miniature pig's ability to ambulate on three legs during the immediate post-operative period and quickly adjust to changes in the exo-prosthesis design, coupled with their physiological similarity to humans, makes them a valuable model for future studies


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_16 | Pages 34 - 34
1 Apr 2013
Koga T Niikura T Lee SY Dogaki Y Okumachi E Waki T Ueha T Sakai Y Oe K Miwa M Kurosaka M
Full Access

Introduction. It is well known that blood flow is a critical key component of fracture repair. Previously, we demonstrated that transcutaneous application of CO2 increased blood flow in the human body. To date, there has been no report investigating the effect of the carbonated therapy on fracture repair. Hypothesis. We hypothesized that the transcutaneous application of CO2 to fracture site would accelerate fracture repair. Materials & Methods. A closed femoral shaft fracture was produced in rats. Transcutaneous CO2 absorption enhancing hydrogel and CO2 adaptor that sealed the body surface and retained the gas inside were used for CO2 treatment. Rats without CO2 treatment served as control. Radiographic, biomechanical and histological analysis was performed to assess the fracture repair. Gene expression of chondrogenic, hypertrophic, osteogenic and angiogenic markers was measured by real-time PCR at 1, 2, 3, and 4 weeks post-fracture. Results. Union rate, biomechanical properties, and gene expression of chondrogenic, hypertrophic, osteogenic and angiogenic markers was significantly higher in CO2 group compared to control group. Histological evaluation demonstrated that enchondral ossification was promoted in CO2 group. Discussion & Conclusions. Our study indicate that transcutaneous application of CO2 accelerates fracture repair via acceleration of endochondral ossification and vascularization, and may become a novel and useful therapy for promoting fracture repair


The Bone & Joint Journal
Vol. 102-B, Issue 1 | Pages 55 - 63
1 Jan 2020
Hagberg K Ghassemi Jahani S Kulbacka-Ortiz K Thomsen P Malchau H Reinholdt C

Aims. The aim of this study was to describe implant and patient-reported outcome in patients with a unilateral transfemoral amputation (TFA) treated with a bone-anchored, transcutaneous prosthesis. Methods. In this cohort study, all patients with a unilateral TFA treated with the Osseointegrated Prostheses for the Rehabilitation of Amputees (OPRA) implant system in Sahlgrenska University Hospital, Gothenburg, Sweden, between January 1999 and December 2017 were included. The cohort comprised 111 patients (78 male (70%)), with a mean age 45 years (17 to 70). The main reason for amputation was trauma in 75 (68%) and tumours in 23 (21%). Patients answered the Questionnaire for Persons with Transfemoral Amputation (Q-TFA) before treatment and at two, five, seven, ten, and 15 years’ follow-up. A prosthetic activity grade was assigned to each patient at each timepoint. All mechanical complications, defined as fracture, bending, or wear to any part of the implant system resulting in removal or change, were recorded. Results. The Q-TFA scores at two, five, seven, and ten years showed significantly more prosthetic use, better mobility, fewer problems, and an improved global situation, compared with baseline. The survival rate of the osseointegrated implant part (the fixture) was 89% and 72% after seven and 15 years, respectively. A total of 61 patients (55%) had mechanical complications (mean 3.3 (SD 5.76)), resulting in exchange of the percutaneous implant parts. There was a positive relationship between a higher activity grade and the number of mechanical complications. Conclusion. Compared with before treatment, the patient-reported outcome was significantly better and remained so over time. Although osseointegration and the ability to transfer loads over a 15-year period have been demonstrated, a large number of mechanical failures in the external implant parts were found. Since these were related to higher activity, restrictions in activity and improvements to the mechanical properties of the implant system are required. Cite this article: Bone Joint J 2020;102-B(1):55–63


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 1 | Pages 114 - 121
1 Jan 2008
Pendegrass CJ Gordon D Middleton CA Sun SNM Blunn GW

Conventional amputation prostheses rely on the attachment of the socket to the stump, which may lead to soft-tissue complications. Intraosseous transcutaneous amputation prostheses (ITAPs) allow direct loading of the skeleton, but their success is limited by infection resulting from breaching of the skin at the interface with the implant. Keratinocytes provide the skin’s primary barrier function, while hemidesmosomes mediate their attachment to natural ITAP analogues. Keratinocytes must attach directly to the surface of the implant. We have assessed the proliferation, morphology and attachment of keratinocytes to four titaniumalloy surfaces in order to determine the optimal topography in vitro. We used immunolocalisation of adhesion complex components, scanning electron microscopy and transmission electron microscopy to assess cell parameters. We have shown that the proliferation, morphology and attachment of keratinocytes are affected by the surface topography of the biomaterials used to support their growth. Smoother surfaces improved adhesion. We postulate that a smooth topography at the point of epithelium-ITAP contact could increase attachment in vivo, producing an effective barrier of infection


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 330 - 330
1 Jul 2008
Martin DJ Patil S Byrne D Leach WJ
Full Access

Aim: We have carried out a prospective study to compare duplex ultrasonography and transcutaneous oxygen tension as predictors of wound healing after knee arthroplasty. Methods and Materials: 53 patients were included in the study. All underwent pre-operative duplex scans of their lower limbs. In addition, transcutaneous oxygen tension measurements were made adjacent to the proposed incision pre-operatively and on days 1, 3 and 7 post knee arthroplasty. Wound healing was assessed using the ASEPSIS wound score. Results: 4 wounds had evidence of delayed wound healing. Duplex ultrasonography was a poor predictor of such problems; however there was a significant correlation between pre-operative transcutaneous oxygen tension and post-operative wound scores. Conclusion: Pre-operative transcutaneous oxygen tension measurement is a better predictor of wound healing after knee replacement surgery than duplex ultrasonograph, and may be a useful adjunct to the investigation of patients at risk of wound problems post knee arthroplasty


Bone & Joint Research
Vol. 10, Issue 10 | Pages 690 - 692
1 Oct 2021
Hoellwarth JS Tetsworth K Akhtar MA Al Muderis M


The Journal of Bone & Joint Surgery British Volume
Vol. 65-B, Issue 1 | Pages 79 - 83
1 Jan 1983
Dowd G Linge K Bentley G

The transcutaneous oxygen pressure (tcPO2) was measured by a polarographic technique in the legs of 161 volunteers and compared with the levels found in 62 patients with ischaemic skin due to peripheral vascular disease. The results show that the tcPO2 was related to the degree of ischaemia and, in many cases, was a more accurate guide to the viability of the skin than clinical assessment. Measurement of the transcutaneous oxygen pressure in the leg at the site of amputation in 24 patients with peripheral vascular disease showed that a preoperative level greater than 40 millimetres of mercury at an electrode temperature of 44 degrees Celsius was necessary for the skin of the stump to heal. The technique is simple, non-invasive and reliable. The tcPO2 accurately reflects the physiological and pathological changes in the circulation of the skin. It has potential in many fields of surgery where careful assessment of the viability of the skin is necessary


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_2 | Pages 11 - 11
1 Jan 2019
Giusto E Pendegrass C Liu C Blunn G
Full Access

Intraosseous Transcutaneous Amputation Prosthesis (ITAP) is a new generation of limb replacements that can provide to amputees, an alternative solution to the main problems caused by the most common used external prosthesis such as pressure sores, infections and unnatural gait. ITAP is designed as one pylon osteointegrated into the bone and protruding through the skin, allowing both the mechanical forces to be directly transferred to the skeleton and the external skin being free from frictions and infections. The skin attachment to the implant is fundamental for the success of the ITAP, as it prevents the implant to move and consequently fail. In this study we wanted to test if cell viability and attachment was improved using TiO2 nanotubes. Human keratinocytes and human dermal fibroblasts were seeded for three days on TiO2 nanotubes with different sizes (18–30nm, 40–60nm and 60–110nm), compared with controls (smooth titanium) and tested for viability and attachment. A Mann-Whitney U test was used to compare groups where p values < 0.05 were considered significant. The results showed that the viability and cell attachment for keratinocytes were significantly higher after three days on controls comparing with all nanotubes (p=0.02), while attachment was higher on bigger nanotubes and controls. Cell viability for fibroblasts was significantly higher on nanotubes between 40 and 110nm comparing with smaller size and controls (p=0.03), while investigation of cell attachment is ongoing. From these early results, we can say that TiO2 nanotubes can improve the soft tissue attachment on ITAP. Further in-vitro and ex-vivo experiments on cell attachment will be carried out


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 148 - 148
1 Nov 2021
Maheu E Soriot-Thomas S Noël E Ganry H Lespesailles E Cortet B
Full Access

Introduction and Objective. Knee osteoarthritis (KOA) is a frequent disease for which therapeutic possibilities are limited. In current recommendations, the first-line analgesic is acetaminophen. However, low efficacy of acetaminophen, frequently leads to the use of weak opioids (WO) despite their poor tolerance, especially in elderly patients. The primary objective was to compare the analgesic efficacy and safety of a new wearable transcutaneous electrical nerve stimulation (W-TENS) to weak opioids (WO) in the treatment of moderate to severe, nociceptive, chronic pain in knee osteoarthritis patients. Materials and Methods. ArthroTENS study is a phase 3, non-inferiority, multicentric, prospective, randomized, single-blinded for primary efficacy outcome, controlled, in 2-parallel groups, clinical study comparing W-TENS versus WO over a 3-month controlled period with an additional, optional, non-controlled, 3-month follow-up for patients in W-TENS group. The co-primary outcome was KOA pain intensity (PI) at month 3 and the number of adverse events (AEs) over 3 months. Results. The non-inferiority of W-TENS was demonstrated in both the PP and ITT populations. At M3, PI in PP population was 3.87 (2.12) compared to 4.66 (2.37) (delta: −0.79 (0.44); 95% CI (−1.65; 0.08)) in W-TENS and WO groups, respectively. Since the absolute value of the 95% CI of the between-treatments mean PI difference [−1.71, – 0.12] was above 0 in ITT set, the planned superiority analysis was performed, demonstrating that W-TENS was significantly superior to WO at M3 (P=0.0124). At M1 and M3, the W-TENS group reached the absolute minimal clinically important difference (MCID) for an analgesic (1.8 (2.1) and 2.1 (2.3), respectively), corresponding to a 20 mm reduction in PI (interquartile range: 15–30) on a 0–100 mm visual analogic scale – i.e. 2 points on a numerical rating scale – which equates to “much better”. Conversely, in the WO group, a 0.5 (1.8) and a 1.1 (2.1) reduction in PI were observed at M1 and M3, respectively, while a 1-point reduction in PI is required to be considered as a “slightly better” improvement. In WO group, AEs were the common systemic AEs reported with WO (nausea, constipation, drowsiness, dizziness, pruritus, vomiting, dry mouth). AEs in W-TENS group were local, such as local cutaneous reaction (erythema). Thirty-nine (70.9%) patients wished to extend W-TENS treatment for 3 additional months. Only one patient discontinued this additional period and results were maintained at M6. Conclusions. W-TENS was more effective and better tolerated than WO in the treatment of nociceptive KOA chronic pain and could represent an interesting non-pharmacological alternative to WO


Aims. The Intraosseous Transcutaneous Amputation Prosthesis (ITAP) may improve quality of life for amputees by avoiding soft-tissue complications associated with socket prostheses and by improving sensory feedback and function. It relies on the formation of a seal between the soft tissues and the implant and currently has a flange with drilled holes to promote dermal attachment. Despite this, infection remains a significant risk. This study explored alternative strategies to enhance soft-tissue integration. Materials and Methods. The effect of ITAP pins with a fully porous titanium alloy flange with interconnected pores on soft-tissue integration was investigated. The flanges were coated with fibronectin-functionalised hydroxyapatite and silver coatings, which have been shown to have an antibacterial effect, while also promoting viable fibroblast growth in vitro. The ITAP pins were implanted along the length of ovine tibias, and histological assessment was undertaken four weeks post-operatively. Results. The porous titanium alloy flange reduced epithelial downgrowth and increased soft-tissue integration compared with the current drilled flange. The addition of coatings did not enhance these effects. Conclusion. These results indicate that a fully porous titanium alloy flange has the potential to increase the soft-tissue seal around ITAP and reduce susceptibility to infection compared with the current design. Cite this article: Bone Joint J 2017;99-B:393–400


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_I | Pages 67 - 68
1 Jan 2011
Chimutengwende-Gordon M Pendegrass C Blunn G
Full Access

Background: Osseointegrated amputation prostheses avoid soft tissue complications associated with traditional socket prostheses. Forces are transmitted directly to the skeleton resulting in improved function. However, approximately 50% of transcutaneous implants become infected due to the lack of a successful skin-implant seal. Intraosseous Transcutaneous Amputation Prostheses (ITAP) are designed to integrate with the skin preventing epithelial downgrowth and infection. Fibronectin adsorption enhances fibroblast adhesion in vitro; however, in vivo, fibronectin becomes desorbed from the implant surface. Covalent attachment of fibronectin by silanisation has been shown to be durable in vitro. The silanisation process for fibronectin includes a stage of passivation with sulphuric acid which alters surface characteristics. Aims: The aim of this study was to determine if in vitro fibroblast adhesion to silanised fibronectin (SiFn) titanium alloy could be improved by omitting or reducing the length of time of passivation. The study also assessed the effects of SiFn on dermal attachment in vivo comparing the results with adsorbed fibronectin substrates and with uncoated controls. Methods: Scanning electron microscopy, Ra profilometry and contact angle measurement (n=6) were used for topographical characterization of surfaces. Anti-vinculin antibodies were used to immunolocalize fibroblast adhesion sites after 24 hours. The morphology of fibroblasts on each surface was evaluated using scanning electron microscopy. Subcutaneous plates were implanted onto the tibiae of an ovine model (n=3) in order to evaluate the performance of the modified SiFn surface in vivo. Hydroxyapatite (HA) and adsorption of fibronectin to HA (HAFn) were also tested because HA coatings are currently applied to the dermal section of ITAP in clinical trials. After four weeks, a histological assessment of the percentage of soft-tissue attachment and cell alignment relative to the implant was performed. Results: Passivation produced rougher, more hydrophobic surfaces with numerous microcracks and was associated with poorer fibroblast adhesion and spreading than un-passivated controls in vitro. SiFn with passivation resulted in poorer cell adhesion than SiFn without passivation. Reducing the time period for passivation did not reduce the detrimental effects of passivation In vivo, HAFn and SiFn resulted in higher median values for soft-tissue attachment than simple adsorption of fibronectin; however, the differences were not statistically significant. Cell alignment was significantly different for HAFn and SiFn compared with controls (p< 0.05), with cells on the fibro-nectin treated surfaces orientated more perpendicular to the implant surface. Conclusion: Omission of passivation improves fibro-blast adhesion to SiFn surfaces in vitro. Coating with fibronectin either by silanisation onto titanium alloy or by adsorption onto HA surfaces affected the orientation of cells in vivo, implying that tissue attachment was enhanced. A time course may be of value to determine if fibronectin coatings are lost over time in vivo


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 1 | Pages 109 - 112
1 Jan 1988
Finsen V Persen L Lovlien M Veslegaard E Simensen M Gasvann A Benum P

We studied the effect of transcutaneous electrical nerve stimulation (TENS) on stump healing and postoperative and late phantom pain after major amputations of the lower limb. A total of 51 patients were randomised to one of three postoperative treatment regimens: sham TENS and chlorpromazine medication, sham TENS only, and active low frequency TENS. There were fewer re-amputations and more rapid stump healing among below-knee amputees who had received active TENS. Sham TENS had a considerable placebo effect on pain. There were, however, no significant differences in the analgesic requirements or reported prevalence of phantom pain between the groups during the first four weeks. The prevalence of phantom pain after active TENS was significantly lower after four months but not after more than one year


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVI | Pages 10 - 10
1 Aug 2012
Pendegrass C Fontaine C Blunn G
Full Access

Infection is the primary failure modality for transcutaneous implants because the skin breach provides a route for pathogens to enter the body. Intraosseous transcutaneous amputation prostheses (ITAP) are being developed to overcome this problem by creating a seal at the skin-implant interface to prevent bacterial invasion. Oral gingival epithelial cell adhesion creates an infection free seal around dental implants; however this has yet to be demonstrated outside the oral environment. All epithelial cells attach via hemidesmosomes (HD) and focal adhesions (FA) and their expression is an indicator of adhesion efficiency. The aim of this study was to compare epidermal keratinocyte with oral gingival epithelial cell adhesion on titanium alloy in vitro to determine whether these two cell types differ in their speed and strength of adhesion. It was hypothesised that oral gingival epithelial cells attach to titanium alloy earlier than epidermal keratinocytes; with greater expression of hemidesmosomes and focal adhesions. Human oral gingival epithelial cell (HGEP) and primary human epidermal keratinocyte (HPEK) adhesion to titanium alloy, was assessed at 4, 24, 48 and 72 hrs. Adhesion was measured by the number of FAs per unit cell area and expression of HDs using a semi-quantitative scale. At 4 and 24hrs, there was a significant increase in vinculin marker expression per unit cell area of 4.3 and 4.7 times in HGEP compared with HPEK (p=0.000). At 48 and 72hrs there were no significant differences. HD expression was significantly greater in HGEP at 4 and 24hrs (p=0.002) compared with HPEK. Up-regulation of HD expression in HPEK lagged that of HGEP until 48hrs, after which no significant differences were observed. This study has demonstrated that oral gingival cells up-regulate both focal adhesion and hemidesmosome expression at earlier time points compared with epidermal keratinocytes. Expression of hemidesmosomes lags that of focal adhesions, suggesting that focal adhesion formation is a prerequisite for hemidesmosome assembly. We postulate that early attachment of oral gingival epithelial cells to dental implant biomaterials may be responsible for the formation of an infection-free seal


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 3 | Pages 465 - 467
1 May 1988
Bongard O Krahenbuhl B

The predictive value of the pedal transcutaneous oxygen tension (tcPO2) and of the distal systolic blood pressure (SBP) in forecasting the necessity for later amputation has been studied in 26 patients suffering from severe chronic ischaemia of the lower limbs. In all these patients vascular surgery had failed or not been possible, and they were threatened by amputation; they suffered from trophic lesions, or pain at rest, or both. The great toe SBP averaged 10 mmHg (range 0 to 60 mmHg) and the pedal tcPO2 10 mmHg (range 2 to 45 mmHg). After six minutes of oxygen inhalation there was an increase in pedal tcPO2 of 9 mmHg (0 to 50 mmHg). After a follow-up period averaging 7 months (range 10 days to 13 months), 13 patients underwent an amputation and nine (five of whom had been amputated) died. The great toe SBP in the patients who required amputation was initially lower than in those who did not. The pedal tcPO2 also was lower in amputated than in non-amputated patients. There was no amputation in the group showing an increase of at least 10 mmHg after six minutes of oxygen inhalation; and conversely, all patients in whom the pedal tcPO2 increased less than 10 mmHg were amputated. Thus increase in the pedal tcPO2 after oxygen inhalation appears the best criterion for estimating the prognosis of severely ischaemic limbs


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 5 | Pages 821 - 824
1 Nov 1988
Kristiansen B Kofoed H

A consecutive series of 31 displaced fractures of the proximal humerus were randomly selected for treatment either by closed manipulation or by transcutaneous reduction and external fixation. Follow-up assessed the quality of reduction and healing as well as the functional outcome. The external fixation method gave better reduction, safer healing and superior function


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 26 - 26
10 Feb 2023
Chavan A Hoellwarth J Tetsworth K Lu W Oomatia A Alam S Vrazas E Al Muderis M
Full Access

Traditional socket prosthesis (TSP) rehabilitation for amputees is associated with substantial dissatisfaction due to poor mobility and pain from soft tissue squeezing. Osseointegration (OI), eliminates skin compression and prosthesis fit issues, providing superior mobility and quality of life (QOL) for most amputees. The potential for OI to benefit patients with exceptionally poor mobility is understudied. To address this knowledge gap, this project investigated the mobility and QOL changes.

A retrospective review was performed to identify transfemoral amputees who presented with wheelchair-bound mobility (K0) and had at least five years of post-osseointegration follow-up. Outcome measures included changes in mobility (K-level, daily prosthesis wear hours, Timed Up and Go (TUG), 6 minute walk test (6MWT)) and QOL (Questionnaire for persons with a Transfemoral Amputation (QTFA); Short Form Health Survey 36 (SF36). Adverse events recorded included debridement for infection, implant revision surgery, fractures, and implant failures.

9 patients with mean age 48.2±7.7 (range 34-59) years were included. The proportion of patients achieving K-level >2 improved from 0/9=0% to [9/9=100%], p<0.001. The 6MWT improved from 0±0 to 320.65±57 meters (p<0.001). The TUG improved from incapable to 10.68±2.7 seconds (p<0.001). Statistically significant QOL metrics included QTFA global score (33.33±31 vs 68.52±21, p=0.039), SF36 physical component score (30.03±6.3 vs 42.34±12, p=0.023) and the SF36 mental component score (47.89±8.8 vs 51.95±10.4, p=0.332). Six patients required operative intervention to address complications. Five developed infections: three had debridement, and 2 required implant removal and reimplantation.

Osseointegration does confer significant sustained mobility and quality of life improvement for wheelchair bound transfemoral amputees. All 9 K0 patients had statistically improved mobility and QOL after osseointegrated reconstruction. This supports osseointegration as an effective rapid and long-term rehabilitation alternative for patients who have the neurologic and muscular capacity to walk but are unable due to issues related to their TSP.


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 3 | Pages 423 - 426
1 May 1986
Christensen K Klarke M

In 42 amputations (28 below-knee and 14 above-knee), healing of the stump was found to correlate with the pre-operative transcutaneous oxygen pressure (tcPO2) measured at the planned site of incision. Of 31 patients with a tcPO2 of 30 mmHg or more, 27 healed primarily, three had delayed healing and one failed to heal; of seven patients with values between 20 and 30 mmHg three healed primarily and four had delayed healing; and all four patients with a value below 20 mmHg had stumps which failed to heal and needed reamputation. It is concluded that a tcPO2 of 20 mmHg or more at the intended site of amputation indicates that the wound will heal


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_13 | Pages 43 - 43
1 Mar 2013
Dowling RP Pendegrass CJ Blunn GW
Full Access

To try and aid the formation of a soft tissue seal to promote dermal and epidermal attachment to Intraosseous Transcutaneous Amputation Prostheses we compared the effect of titanium surfaces functionalised with fibronectin (fn) or YRGD peptide sequences on human dermal cell (HDF) attachment. We hypothesise that YRGD and fn coatings will significantly increase HDF attachment to titanium alloy substrates. Titanium alloy 10mm discs were polished and acted as control substrates, functionalised surfaces had YRGD or fn adsorbed or silanised onto the polished surface. HDFs were seeded at 10,000/disc and cultured for 1, 4, 24 and 96 hours, fixed and fluorescent immnolocalisation for vinculin was performed. Individual vinculin markers were counted and density calculated as a measure of cell attachment. All assays were performed in triplicate and data were analysed in SPSS 19.0 and results were considered significant at the 0.05 level. Results showed an up-regulation of Focal adhesion density (FA) against controls at all time-points (excluding ad-fn at 4 hours, p=0.057), p values < 0.05, the use of functionalised titanium surfaces may lead to long-term clinical success of ITAP. We have shown a significant positive effect on cell attachment when a synthetic peptide sequence is used. Using synthetic peptide sequence may also be more beneficial from a regulatory stand-point compared with using isolated proteins


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 136 - 136
1 Sep 2012
El-Husseiny M Pendegrass C Elnikety S Haddad F Blunn G
Full Access

Introduction. Following amputation, residual stumps used to attach the external prostheses can be associated with sores, infection and skin necrosis. These problems could be overcome by off loading the soft tissues. Intraosseous transcutaneous amputation prostheses (ITAP) attach external implants directly to residual bone reducing these complications. However, a tight seal at the skin implant interface is crucial in preventing epithelial down-growth and infection. Fibronectin (Fn) and laminin 332 (Ln), enhance early cell growth and adhesion of keratinocytes. Silanization to titanium alloy (Ti) allows these proteins to bond to the metal directly. We hypothesize that silanized dual coatings of fibronectin and laminin (SiFnLn) will be more durable than absorbed proteins and that keratinocyte adhesion will be increased compared with Ti controls and single silanized proteins. Methods. 10 mm diameter Ti alloy discs were polished, sterilized and silanized. The kinetics of silanized single and dual protein coating attachment onto titanium alloy was quantified using radio-labelled Fn(125I-Fn) and Ln(125I-Ln). Coating durability was assessed when soaked in fetal calf serum (FCS) for 0, 1, 24, 48, 72hrs. Data was compared to un-silanized Ti discs with the same amount of adsorbed proteins. In order to study cell attachment 20 × 103 keratinocytes were seeded on the discs (n = 6): silanized (Si), silanized fibronectin (SiFn), silanized laminin (SiLn), silanized dual coating (SiFnLn) for 1, 4 and 24hrs. Adhesion of cells was assessed using mouse vinculin antibody for 2hrs and alexafluor for 1hr which stains focal adhesions responsible for attaching cells to surfaces. Axiovision Image Analysis software was used to measure cell area, vinculin markers per cell unit and per unit cell area on 15 cells per disc. Data was analysed in SPSS and significance was assumed at the 0.05 level. Results. Silanized dual coatings bonded to Ti alloy in significantly larger quantities compared with adsorbed coatings (all p values < 0.05). When proteins were combined on silanized discs the same amount of each protein was attached as when used as a single coating (i.e. non competitive binding). Keratinocytes cultured on silanized dual coatings were significantly larger, produced more vinculin markers per unit cell and per cell area compared with single coatings at all time points. Conclusion. This study has demonstrated that silanized using dual proteins on Ti alloy enhances early keratinocyte growth and attachment in vitro. It also shows that there is non-competitive binding of laminin to Ti alloys in presence of fibronectin. This may lead to improved epidermal attachment to ITAP creating a tight seal at the implant interface, which will prevent migration of the epithelium and subsequent infection in vivo


Full Access

Patients with above knee amputation (AKA) often experience poor socket fit exacerbated by minor weight changes, sweating, and skin problems. A transcutaneous, press-fit distal femoral intra-medullary device was designed in 1999, such that the distal external aspect serves as a hard point for AKA prosthesis attachment. The implant is placed in a retrograde fashion, followed 6-8 weeks later by stomatisation and connected via direct extention to an AKA prosthesis. Thirty-seven patients with 39 limbs (30 males, 7 females) underwent two-stage prosthesis implantation with the Endo-Exo Femurprosthesis (EEFP) in Germany between 1999 and January 2008. Their indications for surgery were persistent AKA prosthesis socket difficulties with absence of major comorbid physical or mental illnesses. The patients were followed clinically and radiographically for a minimum of 2 years. Assessments included patient satisfaction ratings, functional surveys, pain scores, and oxygen consumption. Fifty-four percent of patients needed at least one revision (20/37); 80% were minor (16/20) and 20% were major (4/20). Most of the minor revisions were due to soft tissue stomal irritation and occurred prior to a design change in the prosthesis. 2 patients sustained traumatic, peri-trochanteric fractures that were treated operatively proximal to the implant, with retention of the implant. 4 implants were explanted due to infection or prosthesis fracture and 2 of these (50%) were later reimplanted successfully. Overall, 94.9% (37/39) limbs had ultimate EEFP implant success. All functional assessments showed statistically significant improvement over baseline except oxygen consumption, which trended toward improvement. This procedure demonstrated a high degree of functional improvement for the majority of AKA patients treated. Despite an initially high revision rate, the EEFP prosthesis achieves an extremely high rate of successful reconstruction for trans-femoral amputees when more traditional options have failed and therefore warrants further scientific study