header advert
Results 81 - 100 of 2548
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 7 - 7
23 Jun 2023
van Hellemondt GG Faraj S de Windt T van Hooff M Spruit M
Full Access

Pelvic discontinuity (PD) is a detrimental complication following total hip arthroplasty (THA). The aim of this study was to assess the clinical and radiological results of patients with PD who were revised using a custom-made triflange acetabular component (CTAC).

This is a single centre prospective study of patients with PD following THA who were treated with a CTAC. The Hip Disability and Osteoarthritis Outcome Score (HOOS), modified Oxford Hip Score (mOHS), EurQol five-dimension three-level (EQ-5D-3L) utility, and Numeric Rating Scale (NRS), including visual analogue score (VAS) for pain, were gathered at baseline, and at one- and two-year follow-up. Clinical and radiological complications, including reasons for revisions were registered. Trends over time are described and tested for significance and clinical relevance.

18 females with 22 CTACs were included with a mean age of 73.5 years (SD 7.7). There were significant improvements between baseline and final follow-up in HOOS (p<0.01), mOHS (p<0.01), EQ-5D-3L utility (p<0.01), EQ-5D-3L NRS (p<0.01), VAS pain rest (p<0.01), and VAS pain activity (p<0.01). A minimal clinically important improvement in mOHS and the HOOS was observed in 16 patients (73%) and 14 patients (64%), respectively. Definite healing of the PD was observed in 19 hips (86%). Complications included six cases with broken screws (27%), four cases (18%) with bony fractures, and one case (4.5%) with sciatic nerve paresthesia. One patient with concurrent bilateral PD had revision surgery due to recurrent dislocations. No revision surgery was performed for screw failure or implant breakage.

This is the first prospective assessment in clinical outcome of patients with PD who were treated with a CTAC. We have demonstrated that CTAC in patients with THA acetabular loosening and PD can result in stable constructs with no mechanical failures. Moreover, clinically relevant improvements in health-related quality of life at two years’ follow-up was observed.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 3 - 3
23 Jun 2023
Berdis GE Couch CG Larson DR Bedard NA Berry DJ Lewallen DG Abdel MP
Full Access

Cup-cage constructs are one of several methods commonly used to treat severe acetabular bone loss during contemporary revision total hip arthroplasty. The purpose of this study was to provide a long-term results of the technique with emphasis on implant survivorship, radiographic results, and clinical outcomes for both full and half cup-cage reconstructions.

We identified 57 patients treated with a cup-cage reconstruction for major acetabular bone loss between 2002–2012. All patients had Paprosky Type 2B through 3B bone loss, with 60% having an associated pelvic discontinuity. Thirty-one patients received a full cup-cage construct, and 26 a half cup-cage. Mean age at reconstruction was 66 years, 75% were female, and the mean BMI was 27 kg/m2. Mean follow-up was 10 years.

The 10-year cumulative incidences of any revision were 14% and 12% for the full and half cup-cage construct groups, respectively. Of the 9 revisions, 3 were for dislocation, 2 for aseptic loosening and construct failure (both were pelvic discontinuities), 1 for adverse local tissue reaction, and 1 for infection with persistent pelvic discontinuity. The 10-year cumulative incidences of revision for aseptic loosening were 4.5% and 5% for the full and half cup-cage constructs, respectively. Of the unrevised cases, incomplete and non-progressive zone 3 radiolucent lines were observed in 10% of patients in each group. Three patients experienced partial motor and sensory sciatic nerve palsies (2 in the full and 1 in the half cup-cage group). Both the full and half cup-cage cohorts demonstrated significantly improved Harris hip scores.

Full and half cup-cage reconstructions for major acetabular defects were successful at 10 years in regards to acetabular fixation without appreciable differences between the two techniques. However, zone 3 radiolucent lines were not uncommon in association with discontinuities, and dislocation continues to be a problem.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 8 - 8
23 Jun 2023
Baujard A Martinot P Demondion X Dartus J Girard J Migaud H
Full Access

Mechanical irritation or impingement of the iliopsoas tendon accounts for 2–6% of persistent postoperative pain cases after total hip arthroplasty (THA). The most common trigger is anterior cup overhang. CT-scan can be used to identify and measure this overhang; however, no threshold exists for symptomatic anterior iliopsoas impingement. We conducted a case–control study in which CT-scan was used to define a threshold that differentiates patients with iliopsoas impingement from asymptomatic patients after THA.

We analyzed the CT-scans of 622 patients (758 CT-scans) between 2011 and 2020. Out of this population we identified 136 patients with symptoms suggestive of iliopsoas impingement. Among them, 6 were subsequently excluded: three because the diagnosis was reestablished intra-operatively (one metallosis, two anterior instability related to posterior prosthetic impingement) and three because they had another obvious cause of impingement (one protruding screw, one protruding cement plug, one stem collar), leaving 130 patients in the study (impingement) group. They were matched to a control group of 138 patients who were asymptomatic after THA. The anterior cup overhang (anterior margin of cup not covered by anterior wall) was measured by an observer (without knowledge of the clinical status) on an axial CT slice based on anatomical landmarks (orthogonal to pelvic axis).

The impingement group had a median overhang of 8 mm [IQR: 5 to 11] versus 0 mm [IQR: 0 to 4] for the control group (p<.001). Using ROC curves, an overhang threshold of 4 mm was best correlated with a diagnosis of impingement (sensitivity 79%, specificity 85%, PPV = 75%, NPV = 85%).

Pain after THA related to iliopsoas impingement can be reasonably linked to acetabular overhang if it exceeds 4 mm on a CT scan. Below this threshold, it seems logical to look for another cause of iliopsoas irritation or another reason for the pain after THA before concluding impingement is present.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_11 | Pages 2 - 2
7 Jun 2023
Sharrock M Board T
Full Access

It is unclear whether patients with early radiographic osteoarthritis (OA) but severe hip symptoms benefit from total hip replacement (THR). We aimed to assess which factors were associated with successful THR in this patient group.

From a consecutive series of 1,935 patients undergoing THR we identified 70 (3.6%) patients with early OA (Kellgren and Lawrence (KL) grades 0-2). These were compared with 200 patients with advanced OA (KL grades 3–4). Outcomes were Oxford Hip Scores (OHS), EQ5D and EQ-VAS scores; compared pre-operatively with one year post-operatively. We investigated which clinical and radiographic (plain x-ray, CT, MRI) features predicted successful THR in the early OA group. Success was defined as reaching a postoperative OHS≥42.

The early OA group were significantly younger (61 vs 66 years; P=0.0035). There were no significant differences in body mass index, ASA grade or gender. After adjusting for confounders, the advanced OA group had a significantly greater percentage of possible change (PoPC) in OHS (75.8% versus 50.4%; P<0.0001) and improvement in EQ5D (0.151 versus 0.002; P<0.0001). There were no significant differences in complication, revision or readmission rates. In the early OA group, we identified 16/70 (22.9%) patients who had a ‘successful’ THR. Of those with early OA, 38 patients had pre-operative CT or MRI scans. Patients who had a ‘successful’ THR were significantly more likely to have subchondral cysts on CT/MRI (91.7% versus 57.7%; P=0.0362). The presence of cysts on CT/MRI was associated with a significantly greater PoPC in OHS (61.6% versus 38.2%; P=0.0353). The combination of cysts and joint space width (JSW) <1mm was associated with a PoPC of 68%. Plain radiographs were found to significantly underestimate the narrowest JSW compared to CT/MRI (2.4mm versus 1.0mm; P<0.0001).

We advise caution in performing THRs in patients with early OA (KL grades 0-2) on plain radiographs. We advocate pre-operative cross-sectional imaging (CT or MRI) in these patients. In the absence of cysts on cross-sectional imaging, a THR seems unlikely to provide a satisfactory outcome.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 58 - 58
23 Jun 2023
Fontalis A The CS Plastow R Mancino F Haddad FS
Full Access

In-hospital length of stay (LOS) and discharge disposition following arthroplasty could act as surrogate measures for improvement in patient pathways, and have major cost saving implications for healthcare providers. With the ever-growing adoption of robotic technology in arthroplasty, we wished to evaluate its impact on LOS. The objectives of this study were to compare LOS and discharge disposition following robotic-arm assisted (RO THA) versus conventional technique Total Hip Arthroplasty (CO THA).

This large-scale, single institution study included patients of any age undergoing primary THA (N = 1,732) for any cause between May 2019 and January 2023. Data extracted included patient demographics, LOS, need for Post Anaesthesia Care Unit (PACU) admission, anaesthesia type, readmission within 30 days and discharge dispositions. Univariate and multivariate logistic regression models were also employed to identify factors and patient characteristics related to delayed discharge.

The median LOS in the RO THA group was 54 hours (34, 78) versus 60 (51, 100) in the CO THA group, p<0.001. Discharge disposition was comparable between the two groups. In the multivariate model, age, need for PACU admission, ASA score > 2, female gender, general anaesthesia and utilisation of the conventional technique were significantly associated with LOS > 2 days.

Our study showed that robotic-arm assistance was associated with a shorter LOS in patients undergoing primary THA and no difference in discharge destination. Our results suggest that robotic-arm assistance could be advantageous in partly addressing the upsurge of hip arthroplasty procedures and the concomitant health care burden; however, this needs to be corroborated by long-term cost effectiveness analyses and data from randomised controlled studies.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_11 | Pages 3 - 3
7 Jun 2023
Verhaegen J Devries Z Horton I Slullitel P Rakhra K Beaule P Grammatopoulos G
Full Access

Traditional radiographic criteria might underestimate or fail to detect subtle types of acetabular dysplasia. Acetabular sector angles (ASA) can measure the degree of anterior and posterior coverage of the femoral head on computed tomography (CT). This study aims to determine ASA values at different axial levels in a cohort of (1) asymptomatic, high-functioning hips without underlying hip pathology (controls); and (2) symptomatic, dysplastic hips that underwent periacetabular osteotomy (PAO). Thereby, we aimed to define CT-based thresholds for hip dysplasia and its subtypes.

This is an IRB approved cross-sectional study of 51 high functioning, asymptomatic patients (102 hips) (Oxford Hip Score >43), without signs of osteoarthritis (Tönnis grade≤1), who underwent a CT scan of the pelvis (mean age: 52.1±5.5 years; 52.9% females); and 66 patients (72 hips) with symptomatic hip dysplasia treated with peri-acetabular osteotomy (PAO) (mean age: 29.3±7.3 years; 85.9% females). Anterior and posterior acetabular sector angles (AASA & PASA) were measured by two observers at three CT axial levels to determine equatorial, intermediate, and proximal ASA. Inter- and intra-observer reliability coefficient was high (between 0.882–0.992). Cut-off values for acetabular deficiency were determined based on Receiver Operating Characteristic (ROC) curve analysis, area under the curve (AUC) was calculated.

The dysplastic group had significantly smaller ASAs compared to the Control Group, AUC was the highest at the proximal and intermediate PASA. Controls had a mean proximal PASA of 162°±17°, with a cut-off value for dysplasia of 137° (AUC: 0.908). At the intermediate level, the mean PASA of controls was 117°±11°, with a cut-off value of 107° (AUC 0.904). Cut-off for anterior dysplasia was 133° for proximal AASA (AUC 0.859) and 57° for equatorial AASA (AUC 0.868). Cut-off for posterior dysplasia was 102° for intermediate PASA (AUC 0.933).

Measurement of ASA on CT is a reliable tool to identify dysplastic hips with high diagnostic accuracy. Posterior ASA less than 137° at the proximal level, and 107° at the intermediate level should alert clinicians of the presence of dysplasia.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 70 - 70
23 Jun 2023
Muratoglu OK Asik MD Nepple CM Wannomae KK Micheli BR Connolly RL Oral E
Full Access

Majority of ultra-high molecular weight polyethylene (UHMWPE) medical devices used in total joint arthroplasty are crosslinked using gamma radiation to improve wear resistance. Alternative methods of crosslinking are urgently needed to replace gamma radiation due to rapid decline in its supply. Peroxide crosslinking is a candidate method with widespread industrial applications. Oxidative stability and biocompatibility, which are critical requirements for medical device applications, can be achieved using vitamin-E as an additive and by removing peroxide by-products through high temperature melting, respectively. We investigated compression molded UHMWPE/vitamin-E/di-cumyl peroxide blends followed by high-temperature melting in inert gas as a material candidate for tibial knee inserts. Wear resistance increased and mechanical properties remained largely unchanged. Oxidation induction time was higher than most of the other clinically available formulations. The material passed the local-end point biocompatibility tests per ISO 10993. Compounds found in exhaustive extraction were of no concern with margin-of-safety values well above the accepted level, indicating a desirable toxicological risk profile. Peroxide crosslinked, vitamin-E stabilized, and high temperature melted UHMWPE has recently been cleared for clinical use in tibial knee inserts. With all the salient characteristics needed in a material that can provide superior long-term performance in total joint patients, peroxide crosslinking can replace gamma radiation crosslinking of UHMWPE for use in all total joint replacement implant including acetabular liners.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_11 | Pages 11 - 11
7 Jun 2023
McNamara J Eastman J Perring A Vallance N Frigyik A Pollalis A
Full Access

The development and implementation of Enhanced Recovery After Surgery (ERAS) protocols are of particular interest in elective orthopaedics due to clinical benefits and cost effectiveness. The Wycombe Arthroplasty Rapid-Recovery Pathway (WARP) was designed to streamline hip and knee joint arthroplasty to reduce time spent in hospital whilst optimising outcomes in an NHS District General Hospital.

966 patients were admitted to Wycombe General Hospital for primary elective joint replacement (60 UKR, 446 THR, 460 TKR) during the period 1st September 2020 to 31st September 2022. The WARP pathway was used for 357 (37%) patients (32 UKR, 155 THR, 170 TKR) and the standard “non-WARP” pathway was used for 609 (63%) patients (28 UKR 291 THR, 290 TKR). Data was collected on length of stay, time of mobilisation, number of physiotherapy sessions, and inpatient morbidity.

Average length of stay following UKR was 0.75 days for WARP vs 2.96 for non-WARP patients, following THR was 2.17 days for WARP vs 4.17 for non-WARP patients, following TKR was 3.4 days for WARP vs 3.92 for non-WARP patients. Day-0 mobilisation after UKR was achieved in 97% of WARP vs 12% of non-WARP patients, after THR in 43% of WARP vs 14% of non-WARP patients, after TKR in 33% of WARP vs 11% of non-WARP patients. Same-day discharge was achieved in the WARP cohort in 63% of UKR, 10% of THR, 2% of TKR patients. There were no same-day discharges in the non-WARP cohort. Complications delaying mobilisation (pain, nausea/vomiting, dizziness/low BP) were identified in 8.4% of WARP vs 25% of non-WARP patients.

Our cohort study shows that the initiation of WARP Rapid Recovery pathway for joint arthroplasty decreased the average length of stay after UKR by 2.21 days, after THR by 2 days, after TKR by 0.52 days. Time to first mobilisation was decreased significantly by increased rates of same-day mobilisation and reduced rates of postoperative anaesthetic-related complications.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 71 - 71
23 Jun 2023
Sedel L
Full Access

Since 1977 we did implant ceramic on ceramic THR in younger and active population. In 1991 we published (JBJS B N°4) data's in a consecutive group of patients under 50 years of age.

What about the same patients for more than 30 years? Eighty-six hips in 75 patients, 41 males 34 females, mean age 43 (18 to 50), mean weight 68 kg (36 to 100), Charnley class: 38 A, 28 (38 hips) B, 9 patients (10 hips) C. Sixty-six primary procedures, 20 revisions (18 failed arthroplasties: 6 THR, 5 resurfacing, four single cup, two hemiarthroplasty, one bipolar), one after acetabular fractures. Four hips previously infected.

Eight Patients deceased (8 hips) prosthesis still in place, ten lost to follow-up before 2 years, eight hips in 8 patients were revised before the review, partially followed: from 2 to 20 years: 35, completely followed: 25 hips in 23 patients resuming in: No pain in 20, slight pain in 2, severe disability in 3 not related to the hip, no radiolucent lines in 22, radiolucent lines in 3, no osteolysis in 25.

Revision for: early sepsis in one, socket loosening in 8 (3 revisions cases), femoral head fractures in 2: one extra small head (22mm) for Crowe 3 DDH, one fractured at 24 years.

Inertness, stability related to fibrous tissue generation, no noise.


Dual mobility cups (DMC) reduce the risk of dislocation in femoral neck fractures (FNF). Direct anterior approach (DAA), historically promoted for better stability, has been developed in recent years for better functional results. The aim of this study was to compare the early functional results of DMC in FNF by DAA versus posterolateral approach (PLA).

A prospective study was conducted on a continuous series of patients who received DMC for FNF by DAA or PLA. The primary endpoint was Harris Hip Score and Parker score assessed at the first follow-up visit. Intraoperative complications were collected during hospitalization. One year clinical results and all cause revision rate were also collected. Radiographic data of cup positioning and limb length were evaluated.

Fifty-two patients were included in the DAA group and 54 in the PLA group. Two patients were lost to follow-up. The mean age was 72.8 years. There was no significant difference in HHS or Parker score at 3 and 12 months follow up (p=0.6, p= 0.75). DAA was associated with more intraoperative complications with 4 fractures and 1 femoral nerve deficit (p=0.018). There were 3 revisions in the DAA group (1 infection, 1 dislocation, 1 peri prosthetic fracture) and 1 in the PLA group (infection), which was not statistically significant (p=0.34). Cup anteversion was 6° greater and inclination 9° lesser in DAA group (p=0.028, p<0.01).

Results suggest that DAA does not provide any early functional benefit in THA-DMC for FNF compared to PLA. It could lead to more intraoperative complications and a higher revision rate. DAA requires an experienced surgeon and careful patient selection.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 63 - 63
23 Jun 2023
Czubak J Kołodziejczyk K Czwojdziński A Czubak-Wrzosek M
Full Access

The aim of the study was to evaluate radiological and clinical outcomes of surgical treatment of developmental dysplasia of the hip (DDH) with Periacetabular Osteotomy (PAO) and to determine the values of radiological parameters allowing us to obtain an optimal clinical result.

Radiological evaluation included a standardized AP digital radiograph of the hip joints. Centre edge angle (CEA), medialization, distalization, femoral head coverage (FHC) and ilioischial angle were measured. Clinical evaluation based on HHS, WOMAC, Merle d'Aubigne-Postel scales and Hip Lag Sign. Radiological and clinical evaluation was performed preoperatively and approximately 12 months after the surgery.

Statistically significant (p<0.05) differences in radiological measurements and all clinical scales have been observed pre- and postoperatively for all of the parameters. The results of PAO presented decreased medialization by 3.4mm (range: 3 to 3.7), distalization by 3.5mm (range: 3.2 to 3.8) and the ilioischial angle by 2.7° (range: 2.2 to 3.7). There was also an improvement in the femoral head bone coverage: CEA increased by 16.3° (range: 12.1˚ to 20.5˚) and FHC by 15.2% (range: 10.8 to 19.8). Clinically we observed an increase in HHS by 22 points (range: 15.8 to 28.2) and M. Postel d'Aubigne by 3.5 points (range: 2.0 to 4.4) and a decrease in WOMAC by 24% (range: 22.6 to 25.8). HLS improvement of gluteal muscles’ efficiency has been observed in 67% of patients postoperatively.

This study revealed that the qualification of patients with DDH for an elective PAO is more justified due to the predicted optimal clinical outcomes based on three parameters: CEA <25 degrees, FHC <75%, and ilioischial angle >85.9 degrees. Accordingly, to achieve better clinical results for all scales, it is necessary to increase the average CEA value by 11˚, the average FHC by 11%, and reduce the average ilioischial angle by 3˚.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 66 - 66
23 Jun 2023
Chosa E Zhao X
Full Access

Finite element analysis (FEA) has been applied for the biomechanical analysis of acetabular dysplasia, but not for biomechanical studies of periacetabular osteotomy (PAO) or those performing analysis taking into consideration the severity of acetabular dysplasia. This study aimed to perform biomechanical evaluation of changes in stress distribution following PAO and to determine the effect of the severity of developmental dysplasia of the hip (DDH) using three-dimensional FEA.

A normal model was designed with a 25° center-edge (CE) angle and a 25° vertical-center-anterior margin (VCA) angle. DDH models were designed with CE and VCA angles each of 10, 0, or −10°. Post-PAO models were created by separating each DDH model and rotating the acetabular bone fragment in the anterolateral direction so that the femoral head was covered by the acetabular bone fragment, with CE and VCA angles each at 25°.

Compared to the normal hip joint model, the DDH models showed stress concentration in the acetabular edge and contacting femoral head, and higher stress values; stress increased with decreasing CE and VCA angles. Compared to the DDH models, the post-PAO models showed near-normal patterns of stress distribution in the acetabulum and femoral head, with stress concentration areas shifted from the lateral to medial sides. Stress dispersion was especially apparent in the severe acetabular dysplasia models. PAO provided greater decreases in the maximum values of von Mises stress in the load-bearing area of the acetabulum and femoral head when applied to the DDH models of higher degrees of severity, although the values increased with increasing severity of DDH. PAO is expected to provide biomechanical improvement of the hip joint, although the results also suggest a limitation in the applicability of PAO for the patients with severe acetabular dysplasia.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 73 - 73
23 Jun 2023
Sheth N Bostrom M Winzenrieth R Humbert L Pearman L Caminis J Wang Y Boxberger J Krohn K
Full Access

To evaluate the effects of 6 and 18 months of abaloparatide (ABL) compared with placebo (PBO) on bone mineral density (BMD) in the acetabular regions of postmenopausal women with osteoporosis (OP).

Acetabular bone loss, as may occur in OP, increases risk of acetabular fragility fracturesa. In total hip arthroplasty (THA), low acetabular BMD adversely affects primary stability, osseointegration, and migration of acetabular cups.c ABL is an osteoanabolic agent for the treatment of men and postmenopausal women with OP at high risk for fracture. Effects of ABL on acetabular BMD are unknown.

Hip DXA scans were obtained at baseline, 6, and 18 months from a random subgroup of postmenopausal women (aged 49–86 y) from the phase 3 ACTIVE trial randomized to either ABL 80 µg/d or PBO (n=250/group). Anatomical landmarks were identified in each DXA scan to virtually place a hemispherical shell model of an acetabular cup and define regions of interest corresponding to DeLee & Charnley zones 1 (R1), 2 (R2), and 3 (R3). BMD changes compared to baseline were calculated for each zone. Statistical P values were based on a repeated mixed measures model.

BMD in all zones were similar at baseline in the ABL and PBO groups. BMD significantly increased in the ABL group at 6 and 18 months compared with PBO (all P<0.0001 vs PBO). BMD in the PBO group was relatively stable over time.

ABL treatment resulted in rapid and progressive increases in BMD of all 3 acetabular zones. Increasing acetabular BMD has the potential to improve acetabular strength, which may reduce risk of acetabular fragility fractures. In bone health optimization prior to THA, increased acetabular BMD via ABL may provide better primary stability and longevity of acetabular cups in postmenopausal women with OP.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_11 | Pages 16 - 16
7 Jun 2023
Thomas A Wilkinson M
Full Access

The documentation of deep infection rates in joint replacement is fraught with multiple difficulties. Deep infections acquired in theatre may present late, but some later presenting deep infections are clearly haematogenous, and not related to surgical management. The effect of Ultra Clean Air on infection rates was published by Charnley in 1972 (CORR,87:167–187). The data is valuable because large numbers of THRs were performed in standard and Ultra Clean theatres, and detailed microbiology of the air was also recorded. No IV antibiotics were used, so only the effect of air quality was studied.

We extracted the data on theatre type and numbers from Table 3, and numbers and intervals from surgery of deep infections from Table 7. Theatre types with 300 air changes per hour and 3.5 CFU/M3 were classified as Ultra Clean. A logistic regression model was used to examine the effect of theatre type and time elapsed after procedure on the probability of becoming infected.

The model suggests that, controlling for time period, Ultra Clean Air is associated with a significantly lower probability of infection, with an OR of 0.30, p = 2.74 × 10−6. The effect is larger earlier post-surgery, but it does persist. The results are best reviewed as a graphic, which shows that Ultra Clean Air clearly affects the deep infection rate for up to four years post-surgery.

Ultra Clean Air reduces infection rates for up to four years post-surgery, so it is safe to assume that infections presenting after this are haematogenous. Ultra Clean Air does not eliminate early deep infection, so some early infections are not related to air quality. It is not practical to undertake widespread detailed retrospective analyses of cases. When monitoring infection rates there needs to be a balance between failing to record infections related to surgical technique and waiting many years to record low numbers of very late presenting problems. We suggest that registries should regard infections documented within three years of surgery as treatment complications.

For any figures or tables, please contact the authors directly.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 76 - 76
23 Jun 2023
Bloch B James P Manktelow A
Full Access

Sound management decisions are critical to outcomes in revision arthroplasty. Aiming to improve outcomes, revision networks facilitate speciality trained, high volume surgeons, share experience and best practice, contributing to decision making within and away from their base hospital. We have reported the early clinical experience of East Midlands Specialist Orthopaedic Network (EMSON). In this paper we report beneficial clinical effects, both demonstrable and unquantifiable supporting the process.

Using the UK HES database of revisions, performed before and after EMSON was established, (April 2011 – March 2018), data from EMSON hospitals were compared to all other hospitals in the same time-period. Primary outcome was re-revision surgery within 1 year. Secondary outcomes were re-revision, complications within first two years and median LOS.

57,621 RTHA and 33,828 RTKA procedures were involved with around 1,485 (2.6%) and 1,028 (3.0%) respectively performed within EMSON. Re-revision THA rates, within 1 year, in EMSON were 7.3% and 6.0% with re-revision knee rates 11.6% and 7.4%, pre- and post-intervention. Re-revision rates in the rest England in the same periods were 7.4% to 6.8% for hips and 11.7% to 9.7% for knees. This constituted a significant improvement in 1-year re-revision rates for EMSON knees. (β = −0.072 (−0.133 to −0.01), p = 0.024). The reduction in hip re-revision did not reach statistical significance. Secondary outcomes showed a significant improvement for 1 and 2-year RTHA complication rates.

Re-revision rates for RTKA and complication rates for RTHA improved significantly after the introduction of EMSON. Other outcomes studied also improved to a greater extent in the network hospitals. While anecdotal experience with networks is positive, the challenge in collating data to prove clinic benefit should not be underestimated. Beyond the formal process, additional communication, interaction, and support has immeasurable benefit in both elective and emergency scenarios.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_11 | Pages 18 - 18
7 Jun 2023
Schapira B Spanoudakis E Jaiswal P Patel A
Full Access

Surgical trainees are finding it increasingly more challenging to meet operative requirements and coupled with the effects of COVID-19, we face a future of insufficiently trained surgeons. As a result, virtual reality (VR) simulator training has become more prevalent and whilst more readily accepted in certain arthroscopic fields, its use in hip arthroscopy (HA) remains novel. This project aimed to validate VR high-fidelity HA simulation and assess its functional use in arthroscopic training.

Seventy-two participants were recruited to perform two basic arthroscopic tasks on a VR HA simulator, testing hip anatomy, scope manipulation and triangulation skills. They were stratified into novice (39) and experienced (33) groups based on previous arthroscopy experience. Metric parameters recorded from the simulator were used to assess construct validity. Face validity was evaluated using a Likert-style questionnaire. All recordings were reviewed by 2 HA experts for blinded ASSET score assessment.

Experienced participants were significantly faster in completing both tasks compared with novice participants (p<0.001). Experienced participants damaged the acetabular and femoral cartilage significantly less than novice participants (p=0.011) and were found to have significantly reduced path length of both camera and instrument across both tasks (p=0.001, p=0.007), demonstrating significantly greater movement economy. Total ASSET scores were significantly greater in experienced participants compared to novice participants (p=0.041) with excellent correlation between task time, cartilage damage, camera and instrument path length and corresponding ASSET score constituents. 62.5% of experienced participants reported a high degree of realism in all facets of external, technical and haptic experience with 94.4% advising further practice would improve their arthroscopic skills. There was a relative improvement of 43% in skill amongst all participants between task 1 and 2 (p<0.001).

This is the largest study to date validating the use of simulation in HA training. These results confirm significant construct and face validity, excellent agreement between objective measures and ASSET scores, significant improvement in skill with continued use and recommend VR simulation to be a valuable asset in HA training for all grades.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 79 - 79
23 Jun 2023
Paprosky W Gerlinger T
Full Access

Previous reports on the outcomes of isolated head and liner exchange in revision total hip arthroplasty have found high rates of instability following these surgeries. Most reports have studied constructs using ≤28mm femoral heads. The purpose of this study was to determine if modern techniques with the use of larger head sizes can improve the rate of instability after head and liner exchange.

We identified 138 hips in 132 patients who underwent isolated head and liner exchange for polyethylene wear/osteolysis (57%), acute infection (27%), metallosis (13%), or other (2%). All patients underwent revision with either 32mm (23%), 36mm (62%), or 40mm (15%) diameter heads. Crosslinked polyethylene was used in all revisions. Lipped and/or offset liners were used in 104 (75%) hips. Average follow up was 3.5 (1.0–9.1) years. Statistical analyses were performed with significance set at p<0.05.

Revision-free survivorship for any cause was 94.6% and for aseptic causes was 98.2% at 5 years. 11 (8%) hips experienced a complication with 7 (5%) hips requiring additional revision surgery. Following revision, 4 (3%) hips experienced dislocation, 5 (4%) hips experienced infection, and 1 (1%) hip was revised for trunnionosis. No demographic or surgical factors significantly affected outcomes.

Our study shows that isolated head and liner exchange using large femoral heads and modern liners provides for better stability than previous reports. The most common complication was infection. We did not identify specific patient, surgical or implant factors that reduced the risk of instability or other complication.


The Lubinus SP II is an anatomical femoral stem with high survivorship levels notably described in the Swedish Arthroplasty Register. As the clinical and economic burden of revision total hip arthroplasty (THA) and periprosthetic fracture (PPF) continues to increase, it has been suggested that use of anatomical stems may facilitate more uniform cement mantles and improve implant survival. The primary aim of this study was to determine the long-term survivorship and PPF rate of the Lubinus SP II 150mm stem in a single UK centre.

Between January 2007 and April 2012, 1000 consecutive THAs were performed using the Lubinus SP II femoral stem in our institution. Patient demographics and operative details were collected in a prospective arthroplasty database. Patient records and national radiographic archives were then reviewed at a mean of 12.3 years (SD 1.3) following surgery to identify occurrence of subsequent revision surgery, dislocation or periprosthetic fracture.

Mean patient age at surgery was 69.3 years (SD 10.1, 24–93 years). There were 634 women (63%). Osteoarthritis was the operative indication in 974 patients (97%). There were 13 revisions in total (4 for recurrent dislocation, 3 for infection, 6 for acetabular loosening) and 16 dislocations (1.6%). Stem survivorship at 10 years was 99.6% (95 % confidence interval [CI], 99.5%–99.7%) and at 15 years was 98.8% (98.7%–98.9%). The 15-year stem survival for aseptic loosening was 100%. Analysis of all cause THA failure demonstrated a survivorship of 99.1% (99.0%–99.3%) at 10 years and 98.2% (98.1%–98.3%) at 15 years. There were 4 periprosthetic fractures in total (0.4%) at mean 12.3 year follow-up.

The Lubinus SP II stem demonstrated excellent survivorship, low dislocation rates and negligible PPF rates up to 15 years following primary THA. Use of anatomical stems such as the Lubinus SPII would appear to be a wise clinical and economic investment for patients and healthcare systems alike.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_11 | Pages 36 - 36
7 Jun 2023
Hothi H Henckel J Di Laura A Skinner J Hart A
Full Access

3D printing acetabular cups offers the theoretical advantage of enhanced bony fixation due to greater design control of the porous implant surfaces. Analysing retrieved 3D printed implants can help determine whether this design intent has been achieved.

We sectioned 14 off-the-shelf retrieved acetabular cups for histological analysis; 7 cups had been 3D printed and 7 had been conventionally manufactured. Some of the most commonly used contemporary designs were represented in both groups, which were removed due to either aseptic loosening, unexplained pain, infection or dislocation. Clinical data was collected for all implants, including their age, gender, and time to revision.

Bone ingrowth was evaluated using microscopic assessment and two primary outcome measures: 1) bone area fraction and 2) extent of bone ingrowth.

The additively manufactured cups were revised after a median (IQR) time of 24.9 months (20.5 to 45.6) from patients with a median (IQR) age of 61.1 years (48.4 to 71.9), while the conventional cups had a median (IQR) time to revision of 46.3 months (34.7 to 49.1, p = 0.366) and had been retrieved from patients with a median age of 66.0 years (56.9 to 68.9, p = 0.999).

The additively and conventionally manufactured implants had a median (IQR) bone area fraction of 65.7% (36.4 to 90.6) and 33.9% (21.9 to 50.0), respectively (p < 0.001).

A significantly greater amount of bone ingrowth was measured into the backside of the additively manufactured acetabular cups, compared to their conventional counterparts (p < 0.001). Bone occupied a median of 60.0% and 5.7% of the porous depth in the additively manufactured and conventional cups, respectively.

3D printed components were found to achieve a greater amount of bone ingrowth than their conventionally manufactured counterparts, suggesting that the complex porous structures generated through this manufacturing technique may encourage greater osteointegration.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 80 - 80
23 Jun 2023
Halken CH Jensen CB Henkel C Gromov K Troelsen A
Full Access

The interest in day-case hip arthroplasty is increasing; however, there are conflicting results regarding readmission risk, and little is known about patients’ attitude towards day-case surgery. We aimed to investigate differences in 30-day readmission rates between day-case patients and single-overnight-stay patients following total hip arthroplasty (THA) and explore patients’ attitude towards day-case surgery.

From the Danish National Patient Register we identified 29,486 THAs (1353 day-case THAs and 28,133 single-overnight-stay THAs) performed between 2010 and 2020. Day-case surgery was defined as discharge on the day-of-surgery. Overnight admissions within 30 days of surgery were considered readmissions. Differences in readmission rates between day-case and single-overnight-stay patients were investigated using logistic regression adjusted for patient characteristics and year of surgery. In a single-center descriptive study, 2395 hip arthroplasty patients from 2016 to start-2023 answered a questionnaire on patient characteristics, attitude towards day-case surgery and patient-reported outcome measures (PROM).

The overall 30-day readmission rate was 4.4% (CI: 4.2–4.6%) with no difference between day-case (4.4%) and single-overnight-stay THAs (4.4%) (odds-ratio: 1.2 [CI: 0.91–1.6]). In the descriptive study answers to the question whether patients were interested in being discharged on the day of surgery, were: “Yes” = 41%, “Do not know” = 20%, “No” = 39%. Patients responding “No” had lower preoperative PROM-scores, were older (“No” = 70.2 y vs. “Yes” = 65.3 y), and more often female (“No” = 72% vs. “Yes” = 52% female).

Based on nationwide data from 2010–2020, day-case THA patients were not more likely to be readmitted compared to single-overnight-stay patients. However, most patients were not positive towards day-case surgery. While surgeons may consider day-case surgery to be safe, patients are not intuitively positive, indicating an attitude mismatch. To achieve high success rate and patient satisfaction in day-case surgery, shared-decision making initiatives within day-case surgery are needed.