The June 2024 Children’s orthopaedics Roundup360 looks at: Proximal femoral unicameral bone cysts: is ESIN the answer?; Hybrid-mesh casts in the conservative management of paediatric supracondylar humeral fractures: a randomized controlled trial; Rate and risk factors for contralateral slippage in adolescents treated for slipped capital femoral epiphysis; CRP predicts the need to escalate care after initial debridement for musculoskeletal infection; Genu valgum in paediatric patients presenting with patellofemoral instability; Nusinersen therapy changed the natural course of spinal muscular atrophy type 1: what about spine and hip?; The necessity of ulnar nerve exploration and translocation in open reduction of medial humeral epicondyle fractures in children.
Aims. Medial humeral epicondyle fractures (MHEFs) are common elbow fractures in children. Open reduction should be performed in patients with MHEF who have entrapped intra-articular fragments as well as displacement. However, following open reduction, transposition of the ulnar nerve is disputed. The aim of this study is to evaluate the need for ulnar nerve exploration and transposition. Methods. This was a retrospective cohort study. The clinical data of patients who underwent surgical treatment of MHEF in our hospital from January 2015 to January 2022 were collected. The patients were allocated to either transposition or non-transposition groups. Data for sex, age, cause of fracture, duration of follow-up, Papavasiliou and Crawford classification, injury-to-surgery time, preoperative ulnar nerve symptoms, intraoperative exploration of
The aim of this study was to assess and compare active rotation of the forearm in normal subjects after the application of a short-arm cast (SAC) in the semisupination position and a long-arm cast (LAC) in the neutral position. A clinical study was also conducted to compare the functional outcomes of using a SAC in the semisupination position with those of using a LAC in the neutral position in patients who underwent arthroscopic triangular fibrocartilage complex (TFCC) foveal repair. A total of 40 healthy right-handed volunteers were recruited. Active pronation and supination of the forearm were measured in each subject using a goniometer. In the retrospective clinical study, 40 patients who underwent arthroscopic foveal repair were included. The wrist was immobilized postoperatively using a SAC in the semisupination position (approximately 45°) in 16 patients and a LAC in 24. Clinical outcomes were assessed using grip strength and patient-reported outcomes. The degree of disability caused by cast immobilization was also evaluated when the cast was removed.Aims
Methods
Displaced distal radius fractures were investigated at a level 1 major trauma centre during the COVID-19 2020 lockdown due to the implementation of temporary changes in practice. The primary aim was to establish if follow-up at one week in place of the 72-hour British Orthopaedic Association Standards for Trauma & Orthopaedics (BOAST) guidance was safe following manipulation under anaesthetic. A parallel adaptation during lockdown was the non-expectation of Bier’s block. The secondary aim was to compare clinical outcomes with respect to block type. Overall, 90 patients were assessed in a cross-sectional cohort study using a mixed, retrospective-prospective approach. Consecutive sampling of 30 patients pre-lockdown (P1), 30 during lockdown (P2), and 30 during post-lockdown (P3) was applied. Type of block, operative status, follow-up, and complications were extracted. Primary endpoints were early complications (≤ one week). Secondary endpoints were later complications including malunion, delayed union or osteotomy.Aims
Methods
Paediatric supracondylar fractures are the most common elbow fracture in children, and is associated with an 11% incidence of neurologic injury. The goal of this study is to investigate the natural history and outcome of motor nerve recovery following closed reduction and percutaneous pinning of this injury. A total of 246 children who underwent closed reduction and percutaneous pinning following supracondylar humerus fractures were prospectively enrolled over a two year period. Patient demographics (age, weight), Gartland fracture classification, and associated traumatic neurologic injury were collected and analyzed with descriptive statistics. Patients with neurologic palsies were separated based on nerve injury distribution, and followed long term to monitor for neurologic recovery at set time points for follow up. Of the 246 patient cohort, 46 patients (18.6%) sustained a motor nerve palsy (Group 1) and 200 patients (82.4%) did not (Group 2) following elbow injury. Forty three cases involved one nerve palsy, and three cases involved two nerve palsies. No differences were found between patient age (Group 1 – 6.6 years old, Group 2 – 6.2 years old, p = 0.11) or weight (Group 1 – 24.3kg, Group 2 – 24.5kg, p = 0.44). A significantly higher proportion of Gartland type III and IV injuries were found in those with nerve palsies (Group 1 – 93.5%, Group 2 – 59%, p < 0 .001). Thirty four Anterior Interosseous Nerve (AIN) palsies were observed, of which 22 (64.7%) made a full recovery by three month. Refractory AIN injuries requiring longer than three month recovered on average 6.8 months post injury. Ten Posterior Interosseous Nerve (PIN) palsies occurred, of which four (40%) made full recovery at three month. Refractory PIN injuries requiring longer than three month recovered on average 8.4 months post
In response to the COVID-19 pandemic, there was a rapidly implemented restructuring of UK healthcare services. The The Royal National Orthopaedic Hospital, Stanmore, became a central hub for the provision of trauma services for North Central/East London (NCEL) while providing a musculoskeletal tumour service for the south of England, the Midlands, and Wales and an urgent spinal service for London. This study reviews our paediatric practice over this period in order to share our experience and lessons learned. Our hospital admission pathways are described and the safety of surgical and interventional radiological procedures performed under general anaesthesia (GA) with regards to COVID-19 in a paediatric population are evaluated. All paediatric patients (≤ 16 years) treated in our institution during the six-week peak period of the pandemic were included. Prospective data for all paediatric trauma and urgent elective admissions and retrospective data for all sarcoma admissions were collected. Telephone interviews were conducted with all patients and families to assess COVID-19 related morbidity at 14 days post-discharge.Introduction
Methods
Nerve transfer has become a common and often effective reconstructive strategy for proximal and complex peripheral nerve injuries of the upper limb. This case-based discussion explores the principles and potential benefits of nerve transfer surgery and offers in-depth discussion of several established and valuable techniques including: motor transfer for elbow flexion after musculocutaneous nerve injury, deltoid reanimation for axillary nerve palsy, intrinsic re-innervation following proximal ulnar nerve repair, and critical sensory recovery despite non-reconstructable median nerve lesions.Abstract
The treatment for Humeral Supracondylar fractures in children is percutaneous fixation with Kirschner wires using a unilateral or crossed wire configuration. Capitellar entry point with divergent wires is thought crucial in the lateral entry approach. Crossed wire configuration carries a risk of
Closed reduction and percutaneous pinning has become the most common technique for the treatment of Type III displaced supracondylar humerus fractures in children. The purpose of this study was to evaluate whether the loss of reduction in lateral K wiring is non-inferior to crossed K wiring in this procedure. A prospective randomised non-inferiority trial was conducted. Patients aged three to seven presenting to the Emergency Department with a diagnosis of Type III supracondylar humerus fracture were eligible for inclusion in the study. Consenting patients were block randomised into one of two groups based on wire configuration (lateral or crossed K wires). Surgical technique and post-operative management were standardised between the two groups. The primary outcome was loss of reduction, measured by the change in Baumann's angle immediately post –operation compared to that at the time of K wire removal at three weeks. Secondary outcome data collected included Flynn's elbow score, the humero-capitellar angle, and evidence of iatrogenic
In combined high median and
The October 2015 Research Roundup360 looks at: Wasted implants; Biofilms revisited; Peri-operative anticoagulation not required in atrial fibrillation; Determinants in outcome following orthopaedic surgery; Patient ‘activation’ and outcomes; Neuroplasticity and nerve repair; KOOS Score in predicting injury?
The October 2015 Children’s orthopaedics Roundup360 looks at: Radiographic follow-up of DDH; When the supracondylar goes wrong; Apophyseal avulsion fractures; The ‘pulled elbow’; Surgical treatment of active or aggressive aneurysmal bone cysts in children; Improving stability in supracondylar fractures; Biological reconstruction may be preferable in children’s osteosarcoma; The paediatric hip fracture
We conducted an anatomical study to determine
the best technique for transfer of the anterior interosseous nerve (AIN)
for the treatment of proximal
The April 2014 Children’s orthopaedics Roundup360 looks at: urgent supracondylar fractures; rotational osteotomy for synostosis; predicting slip in paediatric forearm fractures; progressive lengthening of the digit is possible; treatment of SUFE with the Dunn osteotomy; and the best way to apply the eight-plate?.
Purposes of study. Evaluation of the pre-operative documentation of neurovascular status in children presenting with Gartland Grades 2 and 3 supracondylar fractures and the development of an Emergency Department Proforma. Methods and results. A retrospective case-note review was performed on patients with Gartland Grade 2 and 3 supracondylar fractures observed in a two-year period from July 2008 – July 2010. 137 patients were included; sixteen patients (11.7%) sustained a Gartland Grade 2a fracture, sixty patients (43.8%) a Gartland Grade 2b fracture and sixty-one (44.5%) a Gartland Grade 3 fracture. Mean patient age at presentation was 5.59 years (range 12 months to 13 years). Nineteen patients (13.9%) had evidence of neurological deficit at presentation and thirteen patients (9.5%) presented with an absent radial pulse. Only twelve patients (8.8%) and nineteen patients (13.9%) respectively had a complete pre-operative neurological or vascular assessment documented. Regarding the individual nerves, fifty-nine (43.1%) patients had median nerve integrity documented, fifty-five (40.1%) ulnar nerve and forty-nine (35.8%) radial nerve integrity documented. Only eighteen patients (13.1%) had their anterior interosseous nerve function documented. Ten patients (7.3%) had post-operative neurological dysfunction, consisting of eight
Aim. To investigate the effectiveness of a decision-based protocol designed to minimise the use of medial incisions when performing crossed-wire fixation of supracondylar fractures of the distal humerus whilst minimising
Supra-condylar humerus fractures (SCHF) are amongst the most common fractures requiring surgical stabilisation in the pediatric age group (1). Closed reduction and percutaneous fixation with Kirschner wires (KW) is currently the standard of care (2). The number of KW used and their configuration has been the subject of much research (3, 4). The failure modes leading to loss of fracture reduction are not clear and have not been quantified. The aim of this study is to compare the mechanical stability of the opt-used configurations for various loading modes and contact interactions at the KW/bone interface. A Gartland type-III SCHF was introduced to a fourth generation composite saw bone (Sawbones®, Vashon, Washington, USA). The model was CT scanned with a slice spacing of 0.5mm and pixel size 0.3×0.3mm. The CT data set was imported into AmiraDev (AmiraDev 5.2 Visage Imaging, Inc). A uniaxial mechanical test was conducted in order to measure the KW pullout forces from the distal humerus. A model of the fractured humerus was constructed with the following steps: 1) manual segmentation; 2) surface generation of each fragment, and; 3) automatic volumetric grid generation for each fragment. The fracture was then virtually reduced and KWs were placed at the desired configurations (Fig 1a-b). For each configuration, a separate model was generated. Material properties were assigned to the bone-model elements according to the manufacturer's data sheet; Young's modulus E = 16GPa and E = 150MPa for the cortical and cancellous bone respectively. The KW were assigned a Young's modulus of 200GPa. Each of the models created in Amira was imported to a finite element application (Abaqus 6.9, DS-Simula) for structural analysis. For each of KW configuration four different torque forces load types were simulated (Fig 1c left): 1) a clockwise and counterclockwise torque with a magnitude of 1.5 NM (Newton/Meters); 2) a translational force with a magnitude of 30 N (Newtons) in the direction of the humerus shaft, and; 3) a shear force with a magnitude of 30 N in the direction parallel to the fracture plane. The results were normalised such that the maximum displacement for the crossed pin configuration with a coefficient of friction equal to zero (μ = 0) was used as unity for each load configuration. Similarly, for each of KW configuration four different translational forces load types were simulated (Fig 1c right): 1) a clockwise and counter clock-wise torque with a magnitude of 1.5 NM (Newton/Meters); 2) a translational force with a magnitude of 30N in the direction of the humerus shaft, and; 3) a shear force with a magnitude of 30N in the direction parallel to the fracture plane. The results were normalised as described above. Results. Torque forces: the crossed configuration was found to be almost independent of the bone-implant friction and was symmetric in terms of direction of the applied torque. The diverging configuration exhibited larger dependency on the bone-implant interface. This is especially noticed as the coefficient of friction (COF) reduced to values below μ = 0.2. Translational forces: the diverging configuration exhibited high sensitivity to reduction of the COF μ = 0. Displacement of the fracture for μ = 0 was substantially larger for the diverging configuration relative to the crossed configuration: 13.5 times and 19 times for the transverse and pullout directions, respectively. As the COF increased to values above μ = 0.5, both fixation configurations performed in a similar manner. Stabilisation of SCHF has been the subject of numerous studies. Relative stability of the different configurations and the risk for iatrogenic
In light of the growing number of elderly osteopenic
patients with distal humeral fractures, we discuss the history of
their management and current trends. Under most circumstances operative
fixation and early mobilisation is the treatment of choice, as it
gives the best results. The relative indications for and results
of total elbow replacement