Advertisement for orthosearch.org.uk
Results 1 - 20 of 2679
Results per page:
Bone & Joint Research
Vol. 13, Issue 12 | Pages 790 - 792
17 Dec 2024
Mangwani J Brockett C Pegg E

Cite this article: Bone Joint Res 2024;13(12):790–792.


Bone & Joint Open
Vol. 5, Issue 12 | Pages 1101 - 1107
11 Dec 2024
Haas-Lützenberger EM Emelianova I Bader MC Mert S Moellhoff N Demmer W Berger U Giunta R

Aims

In the treatment of basal thumb osteoarthritis (OA), intra-articular autologous fat transplantation has become of great interest within recent years as a minimally invasive and effective alternative to surgical intervention with regard to pain reduction. This study aims to assess its long-term effectiveness.

Methods

Patients diagnosed with stage one to three OA received a single intra-articular autologous fat transplantation. Fat tissue was harvested from the abdomen and injected into the trapeziometacarpal (TMC) joint under radiological guidance, followed by one week of immobilization. Patients with a minimum three-year post-procedure period were assessed for pain level (numerical rating scale), quality of life (Mental Health Quotient (MHQ)), the abbreviated version of the Disabilities of Arm, Shoulder and Hand questionnaire (QuickDASH)), and grip and pinch strength, as well as their overall impression of the treatment. Wilcoxon tests compared data from pre-intervention, and at one and three years post-intervention.


Bone & Joint Research
Vol. 13, Issue 12 | Pages 725 - 740
5 Dec 2024
Xing J Liu S

Addressing bone defects is a complex medical challenge that involves dealing with various skeletal conditions, including fractures, osteoporosis (OP), bone tumours, and bone infection defects. Despite the availability of multiple conventional treatments for these skeletal conditions, numerous limitations and unresolved issues persist. As a solution, advancements in biomedical materials have recently resulted in novel therapeutic concepts. As an emerging biomaterial for bone defect treatment, graphene oxide (GO) in particular has gained substantial attention from researchers due to its potential applications and prospects. In other words, GO scaffolds have demonstrated remarkable potential for bone defect treatment. Furthermore, GO-loaded biomaterials can promote osteoblast adhesion, proliferation, and differentiation while stimulating bone matrix deposition and formation. Given their favourable biocompatibility and osteoinductive capabilities, these materials offer a novel therapeutic avenue for bone tissue regeneration and repair. This comprehensive review systematically outlines GO scaffolds’ diverse roles and potential applications in bone defect treatment.

Cite this article: Bone Joint Res 2024;13(12):725–740.


Bone & Joint Open
Vol. 5, Issue 12 | Pages 1072 - 1080
4 Dec 2024
Tang M Lun KK Lewin AM Harris IA

Aims. Systematic reviews of randomized controlled trials (RCTs) are the highest level of evidence used to inform patient care. However, it has been suggested that the quality of randomization in RCTs in orthopaedic surgery may be low. This study aims to describe the quality of randomization in trials included in systematic reviews in orthopaedic surgery. Methods. Systematic reviews of RCTs testing orthopaedic procedures published in 2022 were extracted from PubMed, Embase, and the Cochrane Library. A random sample of 100 systematic reviews was selected, and all included RCTs were retrieved. To be eligible for inclusion, systematic reviews must have tested an orthopaedic procedure as the primary intervention, included at least one study identified as a RCT, been published in 2022 in English, and included human clinical trials. The Cochrane Risk of Bias-2 Tool was used to assess random sequence generation as ‘adequate’, ‘inadequate’, or ‘no information’; we then calculated the proportion of trials in each category. We also collected data to test the association between these categories and characteristics of the RCTs and systematic reviews. Results. We included 917 unique RCTs. We found that 374 RCTs (40.8%) reported adequate sequence generation, 61 (6.7%) were inadequate, 410 (44.7%) lacked information, and 72 (7.9%) were observational studies incorrectly included as RCTs within the systematic review. Publication year, an author with statistical or epidemiological qualifications, and journal impact factor were each associated with adequate randomization. We found that 45 systematic reviews (45%) included at least one inadequately randomized RCT or an observational study incorrectly treated as a RCT. Conclusion. There is evidence of a lack of random allocation in RCTs included in systematic reviews in orthopaedic surgery. The conduct of RCTs and systematic reviews should be improved to minimize the risk of bias from inadequate randomization in RCTs and mislabelling of non-randomized studies as RCTs. Cite this article: Bone Jt Open 2024;5(12):1072–1080


Bone & Joint 360
Vol. 13, Issue 6 | Pages 26 - 29
1 Dec 2024

The December 2024 Wrist & Hand Roundup360 looks at: Variability in thumb ulnar collateral ligament rupture management across the UK: survey insights; Identifying five distinct hand osteoarthritis pain phenotypes highlights the impact of biopsychosocial factors; Long-term outcomes of MAÏA TMC joint prosthesis for osteoarthritis: a possible alternative to trapeziectomy; Diagnostic and management strategies for malignant melanoma of the hand; Early versus delayed surgery for distal radius fractures: comparable outcomes but higher complications in delayed treatment; Perioperative anticoagulant and antiplatelet use does not increase complications in wide-awake hand surgery; Variability in treatment of metacarpal shaft fractures highlights need for standardized care; Low-intensity pulsed ultrasound ineffective in reducing time to union for scaphoid nonunion post-surgery.


The Bone & Joint Journal
Vol. 106-B, Issue 12 | Pages 1485 - 1492
1 Dec 2024
Terek RM

Aims

The aim of the LightFix Trial was to evaluate the clinical outcomes for one year after the treatment of impending and completed pathological fractures of the humerus using the IlluminOss System (IS), and to analyze the performance of this device.

Methods

A total of 81 patients with an impending or completed pathological fracture were enrolled in a multicentre, open label single cohort study and treated with IS. Inclusion criteria were visual analogue scale (VAS) Pain Scores > 60 mm/100 mm and Mirels’ Score ≥ 8. VAS pain, Musculoskeletal Tumor Society (MSTS) Upper Limb Function, and The European Organization for Research and Treatment of Cancer QoL Group Bone Metastases Module (QLQ-BM22) scores were all normalized to 100, and radiographs were obtained at baseline and at 14, 30, 90, 180, and 360 days postoperatively.


Bone & Joint 360
Vol. 13, Issue 6 | Pages 33 - 35
1 Dec 2024

The December 2024 Spine Roundup. 360. looks at: Rostral facet joint violations in robotic- and navigation-assisted pedicle screw placement; The inhibitory effect of non-steroidal anti-inflammatory drugs and opioids on spinal fusion: an animal model;L5-S1 transforaminal lumbar interbody fusion is associated with increased revisions compared to L4-L5 TLIF at two years; Immediate versus gradual brace weaning protocols in adolescent idiopathic scoliosis: a randomized clinical trial; Effectiveness and cost-effectiveness of an individualized, progressive walking, and education intervention for the prevention of low back pain recurrence in Australia (WalkBack): a randomized controlled trial; Usefulness and limitations of intraoperative pathological diagnosis using frozen sections for spinal cord tumours; Effect of preoperative HbA1c and blood glucose level on the surgical site infection after lumbar instrumentation surgery; How good are surgeons at achieving their alignment goals?


The Bone & Joint Journal
Vol. 106-B, Issue 12 | Pages 1363 - 1368
1 Dec 2024
Chen DB Wood JA Griffiths-Jones W Bellemans J Haddad FS MacDessi SJ

As advancements in total knee arthroplasty progress at an exciting pace, two areas are of special interest, as they directly impact implant design and surgical decision making. Knee morphometry considers the three-dimensional shape of the articulating surfaces within the knee joint, and knee phenotyping provides the ability to categorize alignment into practical groupings that can be used in both clinical and research settings. This annotation discusses the details of these concepts, and the ways in which they are helping us better understand the individual subtleties of each patient’s knee.

Cite this article: Bone Joint J 2024;106-B(12):1363–1368.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 13 - 13
22 Nov 2024
McNally M Dietz M Piuzzi N Chen A Parvizi J Stolarski E Pelt C Rodriguez-Quintana D Trautner B Dobbins D
Full Access

Aim. Antimicrobial peptides occur naturally in our intrinsic immune system. PLG0206 is a novel, engineered, 24-amino acid peptide which has broad-spectrum antimicrobial activity, including in biofilm and against multi-drug resistant pathogens (1,2). This is the first clinical study to evaluate the safety and tolerability of PLG0206 when administered via an irrigation solution in patients with periprosthetic joint infections (PJI) following total knee arthroplasty (TKA) during debridement, antibiotics, and implant retention (DAIR). Secondary objectives were to evaluate pharmacokinetics (PK), biomarkers and initial clinical efficacy at one year post-DAIR procedure. Method. This prospective, multicenter, open-label, interventional study assessed two dose levels of PLG0206. Fourteen patients underwent revision for PJI after TKA. At the end of debridement, they received a single intra-articular irrigation of PLG0206 into the wound cavity lasting 15 minutes at concentrations of 3 mg/mL (n=7) or 10 mg/mL (n=7). Patients received post-operative care and intravenous/oral antimicrobial therapy as per their institutional guidelines. Patients were monitored for safety and signs of relapse or persistent infection for 12 months post study drug administration and PK and blood biomarkers were assessed. Results. All patients completed their final study assessment at Day 365. Over the 1-year follow-up, only one recurrence (7%) was noted at Day 169 in the low-dose cohort. Following dosing, nine patients (64.3%) had limited systemic exposure; maximum plasma concentration occurred 1-hour post-administration and declined rapidly to undetectable levels by 24 hours following treatment in all patients. The incidence of drug related treatment-emergent adverse events (TEAEs) was low. Two patients, both in the higher dose cohort, experienced a transient drug related TEAE; one of hypertransaminasaemia and one of neuralgia. Both events were moderate in severity and resolved within two weeks of onset. Conclusions. A single 15-minute irrigation of PLG0206 into the wound cavity of patients undergoing a DAIR procedure for PJI following TKA, is safe and well tolerated by patients. This new antimicrobial peptide offers a promising therapeutic option in musculoskeletal infection. The initial clinical efficacy is encouraging but now needs to be investigated in a much larger clinical trial


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 19 - 19
22 Nov 2024
Hanssen J Veerman K Van der Jagt O Somford M Lammers J Poolman R Peters E Visser J Bos K Verhagen R Vehmeijer S Zijlstra W Nolte P Wouthuyzen-Bakker M Mahdad R Vlasveld I De Boer MG Scheper H
Full Access

Aim. Rifampicin and fluoroquinolone based therapy is generally considered as first-choice targeted oral antimicrobial therapy for staphylococcal prosthetic joint infections (PJI) treated with debridement, antibiotics and implant retention (DAIR). Alternative equally effective antimicrobial strategies are urgently needed due to toxicity and drug-drug interactions that frequently occur with this strategy. Data from recent clinical studies suggests equipoise for other antimicrobial treatment regimens. The objective of the Rifampicin Combination Therapy versus Targeted Antimicrobial Monotherapy in the Oral Antimicrobial Treatment Phase of Staphylococcal Prosthetic Joint Infection (RiCOTTA)-trial is to evaluate whether monotherapy with clindamycin is non-inferior to rifampicin/fluoroquinolone combination therapy in patients with staphylococcal PJI that are treated with DAIR. Method. The RiCOTTA-trial is a multicenter, non-inferiority, open-label, randomized controlled trial evaluating clindamycin versus rifampicin/fluoroquinolone combination therapy in the oral treatment phase in patients with staphylococcal PJI managed with DAIR. The trial is performed in 16 hospitals in the Netherlands. Eligible patients are adults with staphylococcal knee or hip PJI managed by DAIR. Patients are included one to six days before antibiotic treatment is switched from intravenous to oral therapy. Patients with a contraindication for rifampicin, with a megaprosthesis or who receive intravenous antibiotics for more than three weeks after initial debridement are excluded. Primary outcome is treatment success one year after finishing antimicrobial treatment. Success is defined as the absence of: i. Infection related re-surgery, ii. New episode of antibiotic treatment for infection of the index joint after the initial treatment phase of 12 weeks, iii. Ongoing use of antibiotics for the index joint at the end of follow-up, iv. Death. The estimated treatment success of rifampicin combination therapy is 85% and the monotherapy strategy is considered not inferior when the difference in treatment success will be less than 10%. Enrolment of 158 patients per group (316 in total) is needed to confirm non-inferiority of monotherapy with a power of 80%. The trial is currently open for enrolment. The study is approved by the Medical Ethics Committee Leiden, the Hague, Delft, the Netherlands and registered under EU trial number 2022-501620-26-00 in Clinical Trial Information System. Conclusions. Currently, the RiCOTTTA study is the largest randomised clinical trial that compares targeted oral monotherapy with rifampicin combination treatment for staphylococcal PJI. Noninferiority of monotherapy would result in a change in national PJI guidelines and enable clinicians to use a more patient-tailored approach when considering antibiotics for patients during the oral treatment phase of PJI


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 27 - 27
22 Nov 2024
Dudareva M Lama S Scarborough C Miyazaki K Wijendra A Tissingh E Kumin M Scarborough M McNally M
Full Access

Aim. People awaiting surgery for bone and joint infection may be recommended to stop smoking to improve anaesthetic and surgical outcomes. However, restricting curative surgical treatment to non-smokers on the basis of potentially worse surgical outcomes is not validated for functional outcomes or quality of life differences between patients who do and do not smoke. This study used secondary analysis of trial data to ask: do peri-operative non-smokers have a greater improvement in their quality of life 12 months after surgery for bone and joint infection, compared with non-smokers?. Method. Participants in the SOLARIO and OVIVA clinical trials who had complete baseline and 12 month EQ-5D-5L or EQ-5D-3L scores were included. Smoking status was ascertained at baseline study enrolment from participant self-report. Normalised quality of life scores were calculated for participants at baseline and 12 months, based on contemporaneous health state scores for England. Baseline and 12 month scores were compared to calculate a post-operative increment in quality of life. Results. Mean quality of life increment over 12 months was +0.17 for people who reported smoking peri-operatively (95% confidence interval −0.55 to +0.89), compared to +0.23 for people who did not report smoking peri-operatively (95% confidence interval −0.48 to +0.94). Linear regression analysis found no significant difference between the improvement in quality of life for smokers and non-smokers (p>0.1). Mean increments for both groups were greater than estimates of Minimal Clinically Important Difference in quality of life in musculoskeletal conditions. [1,2]. Conclusions. People who smoke peri-operatively still experience an improvement in quality of life after surgery for orthopaedic infections, commensurate with the improvement experienced by non-smokers. Surgery should not be denied to people on the basis of reported smoking status alone


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 90 - 90
14 Nov 2024
Halloum A Rahbek O Gholinezhad S Kold S Rasmussen J Rölfing JD Tirta M Abood AA
Full Access

Introduction. Current treatments of rotational deformities of long bones in children are osteotomies and fixations. In recent years, the use of guided growth for correction of rotational deformities has been reported in several pre-clinical and clinical studies. Various techniques have been used, and different adverse effects, like growth retardation and articular deformities, have been reported. We tested a novel plate concept intended for correction of rotational deformities of long bones by guided growth, with sliding screw holes to allow for longitudinal growth, in a porcine model. Method. Twelve, 12-week-old female porcines were included in the study. Surgery was performed on the left femur. The right femur was used as control. Plates were placed distally to induce external rotation, as longitudinal growth occurred. CT-scans of the femurs were processed to 3-D models and used for measuring rotation. Result. The plates rotated as intended in all 12 porcines. One porcine was excluded due to congenital deformity of the proximal part of the femurs. Two porcines had cut-out of the proximal screw on the lateral side, observed at the end of the intervention. These two porcines were included in the results. We observed a Δrotation of 5.7° ± 2° in external direction (CI: 3.7°– 7.7°). ΔFemur length was -0.4 cm [-0.7 cm – 0 cm] equal to 1.5% shortening of the operated femur. No significant difference was observed in coronal or sagittal plane. Conclusion. Significant external rotation was achieved with minimal effect on longitudinal growth. While the use of guided growth for correction of rotational deformities is already being used clinically, it is still to be considered an experimental procedure with sparse evidence. This study shows promising results for the feasibility of the method in a large animal model and is an important first step in validating the technique and detecting possible adverse effects, before future clinical studies


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 29 - 29
14 Nov 2024
Dhillon M Klos K Lenz M Zderic I Gueorguiev B
Full Access

Introduction. Tibiocalcaneal arthrodesis with a retrograde intramedullary nail is an established procedure considered as a salvage in case of severe arthritis and deformity of the ankle and subtalar joints [1]. Recently, a significant development in hindfoot arthrodesis with plates has been indicated. Therefore, the aim of this study was to compare a plate specifically developed for arthrodesis of the hindfoot with an already established nail system [2]. Method. Sixteen paired human cadaveric lower legs with removed forefoot and cut at mid-tibia were assigned to two groups for tibiocalcaneal arthrodesis using either a hindfoot arthrodesis nail or an arthrodesis plate. The specimens were tested under progressively increasing cyclic loading in dorsiflexion and plantar flexion to failure, with monitoring via motion tracking. Initial stiffness was calculated together with range of motion in dorsiflexion and plantar flexion after 200, 400, 600, 800, and 1000 cycles. Cycles to failure were evaluated based on 5° dorsiflexion failure criterion. Result. Initial stiffness in dorsiflexion, plantar flexion, varus, valgus, internal rotation and external rotation did not differ significantly between the two arthrodesis techniques (p ≥ 0.118). Range of motion in dorsiflexion and plantar flexion increased significantly between 200 and 1000 cycles (p < 0.001) and remained not significantly different between the groups (p ≥ 0.120). Cycles to failure did not differ significantly between the two techniques (p = 0.764). Conclusion. From biomechanical point of view, both tested techniques for tibiocalcaneal arthrodesis appear to be applicable. However, clinical trials and other factors, such as extent of the deformity, choice of the approach and preference of the surgeon play the main role for implant choice. Acknowledgements. This study was performed with the assistance of the AO Foundation


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 87 - 87
14 Nov 2024
Savaş S Konya M Yılmaz BK Kağa S Kağa E Demirel HH
Full Access

Introduction. The Achilles tendon is the thickest and strongest tendon in the human body. Even though the tendon is so strong, it is one of the most frequently injured tendons. Treatment of patients after rupture is planned conservatively and surgically. Conservative treatment is generally applied to elderly patients with sedentary lives. If the treatment is surgical, it can be planned as open surgery or percutaneous surgery. In our study with rabbits, we wrapped a membrane made of plga (polylactic-co-glycolic acid) nanotubes impregnated with type 1 collagen around the tendon in rabbits that underwent open Achilles tendon repair surgery. After surgery, biomechanical and histological tests were performed on the tendons. Method. In the study consisting of 24 rabbits, 2 groups were created by random distribution. In the study group, after the Achilles tendon rupture was created, a type 1 collagen-impregnated plga-based membrane was placed around the tendon after the repair of 1 modified Kesslerr suture. In the control group, after the Achilles tendon rupture was created, 1 modified Kessler suture and Tendon repair was performed with the application of 3 primary sutures. At the end of the 6th week of the study, the rabbits in 2 groups were randomly distributed and histological examination was performed. Additionally, biomechanical testing was performed. Bonar and Movın scoring were used in histological examinations. Result. As a result of biomechanical tests, it was seen that the resistance of the tendon against rupture was higher in the study group than in the control group. In addition, it was observed that the tendon rupture time was longer in the study group than in the control group. Histological examinations gave supportive results from biomechanical tests. Conclusion. We think that the use of collagen-impregnated plga-based nanotubes in the surgical treatment of Achilles tendon ruptures has a positive healing effect. Although we think that the return to normal life after surgery may be faster, we believe that more clinical studies are needed


Bone & Joint Open
Vol. 5, Issue 11 | Pages 1020 - 1026
11 Nov 2024
Pigeolet M Sana H Askew MR Jaswal S Ortega PF Bradley SR Shah A Mita C Corlew DS Saeed A Makasa E Agarwal-Harding KJ

Aims

Lower limb fractures are common in low- and middle-income countries (LMICs) and represent a significant burden to the existing orthopaedic surgical infrastructure. In high income country (HIC) settings, internal fixation is the standard of care due to its superior outcomes. In LMICs, external fixation is often the surgical treatment of choice due to limited supplies, cost considerations, and its perceived lower complication rate. The aim of this systematic review protocol is identifying differences in rates of infection, nonunion, and malunion of extra-articular femoral and tibial shaft fractures in LMICs treated with either internal or external fixation.

Methods

This systematic review protocol describes a broad search of multiple databases to identify eligible papers. Studies must be published after 2000, include at least five patients, patients must be aged > 16 years or treated as skeletally mature, and the paper must describe a fracture of interest and at least one of our primary outcomes of interest. We did not place restrictions on language or journal. All abstracts and full texts will be screened and extracted by two independent reviewers. Risk of bias and quality of evidence will be analyzed using standardized appraisal tools. A random-effects meta-analysis followed by a subgroup analysis will be performed, given the anticipated heterogeneity among studies, if sufficient data are available.


Bone & Joint Open
Vol. 5, Issue 11 | Pages 1003 - 1012
8 Nov 2024
Gabr A Fontalis A Robinson J Hage W O'Leary S Spalding T Haddad FS

Aims

The aim of this study was to compare patient-reported outcomes (PROMs) following isolated anterior cruciate ligament reconstruction (ACLR), with those following ACLR and concomitant meniscal resection or repair.

Methods

We reviewed prospectively collected data from the UK National Ligament Registry for patients who underwent primary ACLR between January 2013 and December 2022. Patients were categorized into five groups: isolated ACLR, ACLR with medial meniscus (MM) repair, ACLR with MM resection, ACLR with lateral meniscus (LM) repair, and ACLR with LM resection. Linear regression analysis, with isolated ACLR as the reference, was performed after adjusting for confounders.


Bone & Joint Open
Vol. 5, Issue 11 | Pages 984 - 991
6 Nov 2024
Molloy T Gompels B McDonnell S

Aims. This Delphi study assessed the challenges of diagnosing soft-tissue knee injuries (STKIs) in acute settings among orthopaedic healthcare stakeholders. Methods. This modified e-Delphi study consisted of three rounds and involved 32 orthopaedic healthcare stakeholders, including physiotherapists, emergency nurse practitioners, sports medicine physicians, radiologists, orthopaedic registrars, and orthopaedic consultants. The perceived importance of diagnostic components relevant to STKIs included patient and external risk factors, clinical signs and symptoms, special clinical tests, and diagnostic imaging methods. Each round required scoring and ranking various items on a ten-point Likert scale. The items were refined as each round progressed. The study produced rankings of perceived importance across the various diagnostic components. Results. In Round 1, the study revealed widespread variability in stakeholder opinions on diagnostic components of STKIs. Round 2 identified patterns in the perceived importance of specific items within each diagnostic component. Round 3 produced rankings of perceived item importance within each diagnostic component. Noteworthy findings include the challenges associated with accurate and readily available diagnostic methods in acute care settings, the consistent acknowledgment of the importance of adopting a patient-centred approach to diagnosis, and the transition from divergent to convergent opinions between Rounds 2 and 3. Conclusion. This study highlights the potential for a paradigm shift in acute STKI diagnosis, where variability in the understanding of STKI diagnostic components may be addressed by establishing a uniform, evidence-based framework for evaluating these injuries. Cite this article: Bone Jt Open 2024;5(11):984–991


The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1306 - 1311
1 Nov 2024
Watts AC McDaid C Hewitt C

Aims

A review of the literature on elbow replacement found no consistency in the clinical outcome measures which are used to assess the effectiveness of interventions. The aim of this study was to define core outcome domains for elbow replacement.

Methods

A real-time Delphi survey was conducted over four weeks using outcomes from a scoping review of 362 studies on elbow replacement published between January 1990 and February 2021. A total of 583 outcome descriptors were rationalized to 139 unique outcomes. The survey consisted of 139 outcomes divided into 18 domains. The readability and clarity of the survey was determined by an advisory group including a patient representative. Participants were able to view aggregated responses from other participants in real time and to revisit their responses as many times as they wished during the study period. Participants were able to propose additional items for inclusion. A Patient and Public Inclusion and Engagement (PPIE) panel considered the consensus findings.


The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1327 - 1332
1 Nov 2024
Ameztoy Gallego J Diez Sanchez B Vaquero-Picado A Antuña S Barco R

Aims

In patients with a failed radial head arthroplasty (RHA), simple removal of the implant is an option. However, there is little information in the literature about the outcome of this procedure. The aim of this study was to review the mid-term clinical and radiological results, and the rate of complications and removal of the implant, in patients whose initial RHA was undertaken acutely for trauma involving the elbow.

Methods

A total of 11 patients in whom removal of a RHA without reimplantation was undertaken as a revision procedure were reviewed at a mean follow-up of 8.4 years (6 to 11). The range of motion (ROM) and stability of the elbow were recorded. Pain was assessed using a visual analogue scale (VAS). The functional outcome was assessed using the Mayo Elbow Performance Score (MEPS), the Oxford Elbow Score (OES), and the Disabilities of the Arm, Shoulder and Hand questionnaire (DASH). Radiological examination included the assessment of heterotopic ossification (HO), implant loosening, capitellar erosion, overlengthening, and osteoarthritis. Complications and the rate of further surgery were also recorded.


The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1273 - 1283
1 Nov 2024
Mahmud H Wang D Topan-Rat A Bull AMJ Heinrichs CH Reilly P Emery R Amis AA Hansen UN

Aims

The survival of humeral hemiarthroplasties in patients with relatively intact glenoid cartilage could theoretically be extended by minimizing the associated postoperative glenoid erosion. Ceramic has gained attention as an alternative to metal as a material for hemiarthroplasties because of its superior tribological properties. The aim of this study was to assess the in vitro wear performance of ceramic and metal humeral hemiarthroplasties on natural glenoids.

Methods

Intact right cadaveric shoulders from donors aged between 50 and 65 years were assigned to a ceramic group (n = 8, four male cadavers) and a metal group (n = 9, four male cadavers). A dedicated shoulder wear simulator was used to simulate daily activity by replicating the relevant joint motion and loading profiles. During testing, the joint was kept lubricated with diluted calf serum at room temperature. Each test of wear was performed for 500,000 cycles at 1.2 Hz. At intervals of 125,000 cycles, micro-CT scans of each glenoid were taken to characterize and quantify glenoid wear by calculating the change in the thickness of its articular cartilage.